test report issued under the responsibility of - 솔루엠 · test report issued under the...

13

Upload: vudung

Post on 11-May-2018

217 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Test Report issued under the responsibility of - 솔루엠 · Test Report issued under the responsibility of: NCB TÜ V SÜ D PSB Pte Ltd 1 Science Park Drive, ... (CM104) Pilkor
Page 2: Test Report issued under the responsibility of - 솔루엠 · Test Report issued under the responsibility of: NCB TÜ V SÜ D PSB Pte Ltd 1 Science Park Drive, ... (CM104) Pilkor
Page 3: Test Report issued under the responsibility of - 솔루엠 · Test Report issued under the responsibility of: NCB TÜ V SÜ D PSB Pte Ltd 1 Science Park Drive, ... (CM104) Pilkor

Test Report issued under the responsibility of:

NCB TÜ V SÜ D PSB Pte Ltd

1 Science Park Drive, Singapore 118221

TEST REPORT IEC/EN 61347-2-13

Part 2: Particular requirements: Section Thirteen – d.c. or a.c. supplied electronic controlgear for

LED modules

Report Number. .............................. : 077-2341013-001

Date of issue..................................... : 2013-12-26

Total number of pages ...................... 11 pages

Applicant’s name ............................ : Samsung Electro-Mechanics Co., Ltd.

Address ............................................ :

314 Maetan-3Dong, Yeongtong-Gu, Suwon-City, Gyeonggi-Do, 443-743, Republic of Korea

Test specification:

Standard ........................................... : IEC/EN 61347-2-13:2006 used in conjunction with IEC 61347-1 (Second Edition) : 2007+A1:2010

Test procedure ................................. : CB Scheme

Non-standard test method…………..: N/A

Test Report Form No. ..................... : IEC/EN61347_2_13C

Test Report Form(s) Originator ........ : Intertek Semko AB

Master TRF....................................... : 2011-06

Copyright © 2011 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved.

This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.

If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.

Test item description ..................... : Electronic controlgear for LED modules

Trade Mark ....................................... : ,

Manufacturer .................................... : Same as Applicant

Model/Type reference ...................... : PSDV151101*

Ratings ............................................. : Input: 100-277 Va.c.; 50/60Hz; 200 W; 2 A Max, PF=0.9;

ta=-40°C - +50°C; tc=+90°C

Output: 100 - 210 Vd.c. / 700mA, 13.2 Vd.c. / 50 mA

Page 4: Test Report issued under the responsibility of - 솔루엠 · Test Report issued under the responsibility of: NCB TÜ V SÜ D PSB Pte Ltd 1 Science Park Drive, ... (CM104) Pilkor

Page 2 of 11 Report No.: 077-2341013-001

TRF No. IEC61347_2_13C

Testing procedure and testing location:

CB Testing Laboratory:

Testing location/ address .......................... : TÜ V SÜ D Korea Laboratory (TKL)

#315 and 316, MARIO Tower, 222-12, Guro-dong, Guro-Gu, Seoul, Korea

Associated CB Laboratory:

Testing location/ address .......................... : N/A

Tested by (name + signature) ......... :

Danny Shin

…………………………………….

Approved by (+ signature) ............... :

Daniel Kim

…………………………………….

Testing procedure: TMP

Testing location/ address .......................... :

Tested by (name + signature) ......... :

Approved by (+ signature) ............... :

Testing procedure: WMT

Testing location/ address .......................... :

Tested by (name + signature) ......... :

Witnessed by (+ signature) ............. :

Approved by (+ signature) ............... :

Testing procedure: SMT

Testing location/ address .......................... :

Tested by (name + signature) ......... :

Approved by (+ signature) ............... :

Supervised by (+ signature) ............ :

Testing procedure: RMT

Testing location/ address .......................... :

Tested by (name + signature) ......... :

Approved by (+ signature) ............... :

Supervised by (+ signature) ............ :

Page 5: Test Report issued under the responsibility of - 솔루엠 · Test Report issued under the responsibility of: NCB TÜ V SÜ D PSB Pte Ltd 1 Science Park Drive, ... (CM104) Pilkor

Page 3 of 11 Report No.: 077-2341013-001

TRF No. IEC61347_2_13C

List of Attachments (including a total number of pages in each attachment):

None

Summary of testing:

Tests performed (name of test and test clause): All tests

Testing location: As above testing laboratory

Summary of compliance with National Differences:

List of countries addressed:

The product fulfils the requirements of EN 61347-2-13:2006 used in conjunction with EN 61347-1:2008

Page 6: Test Report issued under the responsibility of - 솔루엠 · Test Report issued under the responsibility of: NCB TÜ V SÜ D PSB Pte Ltd 1 Science Park Drive, ... (CM104) Pilkor

Page 4 of 11 Report No.: 077-2341013-001

TRF No. IEC61347_2_13C

Copy of marking plate

The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective NCBs that own these marks.

Test item particulars .............................................. :

Classification of installation and use ........................ : Built-in controlgear

Supply Connection ................................................... : Insulated wires

.................................................................................. :

.................................................................................. :

Possible test case verdicts:

- test case does not apply to the test object ............. : N/A

- test object does meet the requirement ................... : P (Pass)

- test object does not meet the requirement ............. : F (Fail)

Testing ..................................................................... :

Date of receipt of test item ....................................... : N/A

Date (s) of performance of tests ............................... : N/A

Page 7: Test Report issued under the responsibility of - 솔루엠 · Test Report issued under the responsibility of: NCB TÜ V SÜ D PSB Pte Ltd 1 Science Park Drive, ... (CM104) Pilkor

Page 5 of 11 Report No.: 077-2341013-001

TRF No. IEC61347_2_13C

General remarks:

The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma (point) is used as the decimal separator. Clause numbers between brackets refer to clauses in IEC 61347-1

Remark 1 – This amendment report is to supplement the earlier CB Ref. Cert. No. LE00715 (Test Report Ref. No.: 077-2341013-000)

- AC input wire is added by alternatively.,

- No electrical tests were considered.

Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:

The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided .............................................................. :

Yes

Not applicable

When differences exist; they shall be identified in the General product information section.

Name and address of factory (ies) ……. :

Factory 1: Same as Applicant.

Factory 2: Dongguan Samsung Electro-Mechanics Co., Ltd. HENGKENG MANAGEMENT AREA, LIAOBU TOWN, DONGGUAN CITY, GUANGDONG PROVINCE 523413 People’s Republic of China

Factory 3: DONGGUAN SOLYTECH ENTERPRISE CORPORATION Hong Men Shan Industrial Area, Chang Shan Tou Management Area, Qing Xi Town, Dong Guan City, Guang Dong Province 523661 People's Republic of China

Factory 4: Dongguan IM Digital Electronics Co., Ltd. Baiye Ind. Zone, LiaoBu Town, DongGuan City Guang Dong Province, People’s Republic of China

Factory 5: Samsung Electro-Mechanics Thailand Co., Ltd. Wellgro Industrial Estate, 93 Moo 5 T. Bangsamak, A. Bangpakong, Chachoengsao, Thailand

Factory 6: DONG GUAN APtech ELECTRONICS CO., LTD.

Jinfu 2 Road, TangChun East Area, TangChun Village, LiaoBu Town 523407 DongGuan City, GuangDong Province, PEOPLE’S REPUBLIC OF CHINA

Factory 7: Dongguan City Yingju Electronics Co., Ltd. Yewuji Village, Sijia, Shijie Town Dongguan, Guangdong 523300 People’s Republic of China Factory 8: HK Towada Electronics Co., Ltd. Dongguan Zhangmutou Towada Electronics

Factory, Fu Da Ind, Zhangyang District,

Zhangmutou, Dongguan City, Guang Dong,

523636, People’s Republic of China

Page 8: Test Report issued under the responsibility of - 솔루엠 · Test Report issued under the responsibility of: NCB TÜ V SÜ D PSB Pte Ltd 1 Science Park Drive, ... (CM104) Pilkor

Page 6 of 11 Report No.: 077-2341013-001

TRF No. IEC61347_2_13C

General product information:

1. The product was LED control gear and prepared for Class I construction.

2. User’s manual is not provided and should be considered in the end product.

3. Model differences: PSDV151101* “ * ” can be alphabetical character A or B, denote buyer request code.

4. All requirements should be fulfilled to standard of IEC/EN 61347-2-13:2006 used in conjunction with IEC 61347-1 (Second Edition) : 2007+A1:2010, when installing in the end product.

Page 9: Test Report issued under the responsibility of - 솔루엠 · Test Report issued under the responsibility of: NCB TÜ V SÜ D PSB Pte Ltd 1 Science Park Drive, ... (CM104) Pilkor

Page 7 of 11 Report No.: 077-2341013-001

IEC 61347-2-13

Clause Requirement + Test Result - Remark Verdict

TRF No. IEC61347_2_13C

ANNEX 1: components P

object/part No. code manufacturer/ trademark

type/model technical data

standard mark(s) of conformity

Fuse (FS101)

A Littelfuse Wickmann

369 300V, T5AL IEC 60248-1 VDE

Varistor

(VX101S)

A Amotech Co., Ltd

INR14D751 750Vrms, 4.5kA,

IEC 61051-2 VDE

D THINGKING ELECTRONICSINDUSTRIAL CO LTD

TVR14751 750Vrms, 4.5kA,

IEC 61051-2 VDE

Thermistor (NT101S)

A DSC DSC-2.5D-15 2.5ohm, 8A IEC 61347-1 Tested in apparatus

Alternate D Thinking Electronic Industrial Co., Ltd.

SCK152R58 2.5ohm, 8A IEC 61347-1 Tested in apparatus

X-Capacitor (CX101S, CX102S)

A Pilkor Electronics Co., Ltd.

PCX2 339 305Vac, 330 nF

IEC 60384-14 EN 60384-14

ENEC

BleederResistors

(RX101S, RX102S, RX103S)

C Yageo Corporation

RC3216 330 Kohm, Min. 1/4 W (Located after the mains fuse)

IEC61347-1 Tested in apliance

Alternate D Semco RC1206

Coupling Capacitor (CY106S, CY201S)

A Dong Il Electronics Co., Ltd.

DA Max. 3300 pF, 400 Vac, Y1

IEC 60384-14 EN 60384-14

ENEC 14, SEMKO ,UL, VDE

Line Filter (LX101S)

C TNC CV620280SH Min.130 °C IEC 61347-1 Tested in apparatus

Alternate D Kwangsung KV620280S

Min.130 °C IEC 61347-1 Tested in apparatus

Line Filter (LX102S)

C TNC CV630110SH Min.130 °C IEC 61347-1 Tested in apparatus

Alternate D Kwangsung KV630110S

Min.130 °C IEC 61347-1 Tested in apparatus

Line Filter (LQ01)

C LI SHIN Electronic Limited

102L Min.130 °C IEC 61347-1 Tested in apparatus

Alternate D Kwangsung 102K Min.130 °C IEC 61347-1 Tested in apparatus

Coil(L02) C LI SHIN Electronic Limited

251L Min.130 °C IEC 61347-1 Tested in apparatus

Alternate Kwangsung 251K Min.130 °C IEC 61347-1 Tested in apparatus

Page 10: Test Report issued under the responsibility of - 솔루엠 · Test Report issued under the responsibility of: NCB TÜ V SÜ D PSB Pte Ltd 1 Science Park Drive, ... (CM104) Pilkor

Page 8 of 11 Report No.: 077-2341013-001

IEC 61347-2-13

Clause Requirement + Test Result - Remark Verdict

TRF No. IEC61347_2_13C

Coil(L01) C TNC Co Ltd PVA30180 Min.130 °C IEC 61347-1 Tested in apparatus

Bridge Diode (BD101)

C Vishay LVB2560 25 A, 600 V IEC 61347-1 Tested in apparatus

Alternate D Interchangeable Interchangeable

PFC (LP01) C Jinlong machinery & electronics co ltd

SL150-PFC Min.130 °C IEC 61347-1 Tested in apparatus

Alternate D LI SHIN Electronic Limited

SL150-PFC Min.130 °C IEC 61347-1 Tested in apparatus

Elec. Capacitor (CP151)

C Interchangeable Interchangeable 500V, 100uF IEC 61347-1 Tested in apparatus

Film capacitor (CP171)

C Pilkor Electronics Co., Ltd.

PCMP 500V, 1000nF

IEC 61347-1 Tested in apparatus

Film capacitor (CM104)

C Pilkor Electronics Co., Ltd.

PCMP Min. 1250V, 10nF

IEC 61347-1 Tested in apparatus

Alternate D Sungho MPP, MPE, FMPE, BFMPE

Min. 1250V, 10nF

IEC 61347-1 Tested in apparatus

FET (QP101) C Infineon SPA17N80C3 Min.17 A, 800 V

IEC 61347-1 Tested in apparatus

FET (QM102, QM103)

C Toshiba TK13A60D Min.13 A, 600 V

IEC 61347-1 Tested in apparatus

Alternate D STM STF13NM60N Min.11 A, 600 V

IEC 61347-1 Tested in apparatus

Driver Transformer (PM101)

C Clover Hi-tech PD46F1-PT Min.130 °C IEC 61347-1 Tested in apparatus

Transformer (TM01)

C LI SHIN Electronic Limited

SL150-LM Class B IEC 61637-1 Tested in apparatus

Alternate D Top nation SL100-LM Class B IEC 61637-1 Tested in apparatus

Opto-coupler (PC101S)

A Lite-On Technology Corp.

LTV-217B Isolation voltage 3750V or 5000 V, Through insulation: 0.5 mm, Internal: 4.4 mm, External: 5.1 mm

IEC 60065, EN 60065, IEC 60950-1, EN 60950-1

FIMKO, UL, VDE, SEMKO

Page 11: Test Report issued under the responsibility of - 솔루엠 · Test Report issued under the responsibility of: NCB TÜ V SÜ D PSB Pte Ltd 1 Science Park Drive, ... (CM104) Pilkor

Page 9 of 11 Report No.: 077-2341013-001

IEC 61347-2-13

Clause Requirement + Test Result - Remark Verdict

TRF No. IEC61347_2_13C

Alternate D Vishay Semiconductor GMBH

SFH690 Through insulation: 0.5 mm, Internal: 4.8 mm, External: 5.6 mm

Insulation sheet A Toray Industries Ltd

Lumirror(#) VTM-2, 105 °C, 0.18 mm thick.

UL 94 UL (E86511)

PCB A Interchangeable Interchangeable Min. V-0, 105°C

UL 94 UL

Wire stopper A Interchangeable Interchangeable Min. V-1, Min.105°C

UL 94 UL

AC input wire A KI SEONG 1015 Min.300 V,

18 AWG,

Min. 90 °C

UL 758 UL/cUL

Alternate D WEIHAISHI HONGLIN WIRE & CABLE

1015 Min.300 V,

18 AWG,

Min. 90 °C

UL 758 UL/cUL

Alternate D HAE KWANG

CABLE

1015 Min.300 V,

18 AWG,

Min. 90 °C

UL 758 UL/cUL

Alternate D HSHINHWA ELECTRIC WIRE

1015 Min.300 V,

18 AWG,

Min. 90 °C

UL 758 UL/cUL

Alternate D DAE YOUNG WIRE(TIANJIN)

1015 Min.300 V,

18 AWG,

Min. 90 °C

UL 758 UL/cUL

Alternate D THAI WONDERFUL WIRE CABLE CO.,LTD

1015 Min.300 V,

18 AWG,

Min. 90 °C

UL 758 UL/cUL

Alternate D ELETECK WIRE & CABLE CO LTD

1015 Min.300 V,

18 AWG,

Min. 90 °C

UL 758 UL/cUL

Alternate D LTK WIRING CO LTD

1015 Min.300 V,

18 AWG,

Min. 90 °C

UL 758 UL/cUL

Alternate D WONDERFUL HI-TECH CO LTD

1015 Min.300 V,

18 AWG,

Min. 90 °C

UL 758 UL/cUL

Alternate D SHENZHEN LINOYA ELECTRONIC CO LTD

1015 Min.300 V,

18 AWG,

Min. 90 °C

UL 758 UL/cUL

Page 12: Test Report issued under the responsibility of - 솔루엠 · Test Report issued under the responsibility of: NCB TÜ V SÜ D PSB Pte Ltd 1 Science Park Drive, ... (CM104) Pilkor

Page 10 of 11 Report No.: 077-2341013-001

IEC 61347-2-13

Clause Requirement + Test Result - Remark Verdict

TRF No. IEC61347_2_13C

Alternate D HAE KWANG

CABLE

2517 Min.300 V,

Min. 105 °C, 18 AWG

UL 758 UL/cUL

Alternate D Korea KDK SJT Min.300 V, 105 °C, 18AWG

UL 758 UL/cUL

Alternate D DO WOO ELECTRIC WIRE CO LTD

2517 Min.300 V, 105 °C, 18AWG

UL 758 UL/cUL

Alternate D KI SEONG K60227 IEC 53 VCTF 5CX0.75mm

2-

2.5mm2

Min.300 V, 90 °C, 0.75

or 1.0 ㎟

K60227-5 KC

Alternate D KI SEONG 60227 KSC IEC 08

Min.300 V, 90 °C, 0.75

or 1.0 ㎟

K60227-1 KC

Alternate D HAE KWANG

CABLE

AWM 1618 Min.300 V, 18 AWG, 90 °C

UL 758 CSA,UL

Alternate D CHANGSHU HONG-LIN Cable Co.,Ltd

HVSF Min.300 V, 90 °C, 0.75

or 1.0 ㎟

JIS C 3306 PSE

Alternate D DAE YOUNG WIRE

HVSF Min.300 V, 90 °C, 0.75

or 1.0 ㎟

JIS C 3306 PSE

Alternate D THAI WONDERFUL WIRE CABLE CO.,LTD

HVSF Min.300 V, 90 °C, 0.75

or 1.0 ㎟

JIS C 3306 PSE

Alternate D CHANGSHU HONG-LIN WIRE & Cable Co.,Ltd

60227 IEC 06 Min.300 V, 90 °C, 0.75

or 1.0 ㎟

GB5023.3 CCC

Alternate D LTK Cable 60227 IEC 08 Min.300 V, 90 °C, 0.75

or 1.0 ㎟

GB5023.3 CCC

Alternate D Samwon Electric Cable

60227 IEC 08 Min.300 V, 90 °C, 0.75 or 1.0 or 1.5

KS C IEC60227-3

IEC,KC

Alternate D Doowon Cable 60227 IEC 08 Min.300 V, 90 °C, 0.75

or 1.0㎟

KS C IEC60227-3

IEC,KC

Alternate D DAE YOUNG WIRE

60227 IEC 08 Min.300 V, 90 °C, 0.75

or 1.0 ㎟

KS C IEC60227-3

IEC,KC

Supplementary information:

Bold characters are alternation for alteration of components.

Page 13: Test Report issued under the responsibility of - 솔루엠 · Test Report issued under the responsibility of: NCB TÜ V SÜ D PSB Pte Ltd 1 Science Park Drive, ... (CM104) Pilkor

Page 11 of 11 Report No.: 077-2341013-001

IEC 61347-2-13

Clause Requirement + Test Result - Remark Verdict

TRF No. IEC61347_2_13C

The codes above have the following meaning:

A - The component is replaceable with another one, also certified, with equivalent characteristics

B - The component is replaceable if authorised by the test house

C - Integrated component tested together with the appliance

D - Alternative component