Page 1: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

www.inoksan.com

TEZGAH TİPİ COUNTER TYPE REFRIGERATOR

KULLANIM KILAVUZU TRINSTRUCTIONS MANUAL GB

ИНСТРУКЦИЯ ПО ЭКСПЛУАТАЦИИ РУ

MODEL

SBN146- 196 - 246 - 140 - 190 - 240

SBP146- 196 - 246 - 140 - 190 - 240

SBM146- 196 - 246 - 140 - 190 - 240

SBE146- 196 - 246 - 140 - 190 - 240

Page 2: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken
Page 3: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

08 - 23

24 - 28

29 - 36

İÇİNDEKİLER

INDEX

TR / TEZGAH TİPİ BUZDOLABI

GB / COUNTER TYPE REFRIGERATORPY / СЧЕТЧИК Тип холодильник

Page 4: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken
Page 5: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

PASLANMAZ TABLALI TEZGAH TİPİ BUZDOLABI*TEZGAH TİPİ BUZDOLABI............................................ INO-SBN146*TEZGAH TİPİ BUZDOLABI............................................ INO-SBN196*TEZGAH TİPİ BUZDOLABI............................................ INO-SBN246*TEZGAH TİPİ BUZDOLABI............................................ INO-SBN140*TEZGAH TİPİ BUZDOLABI............................................ INO-SBN190*TEZGAH TİPİ BUZDOLABI............................................ INO-SBN240

POLİETİLEN TABLALI TEZGAH TİPİ BUZDOLABI*TEZGAH TİPİ BUZDOLABI............................................ INO-SBP146*TEZGAH TİPİ BUZDOLABI............................................ INO-SBP196*TEZGAH TİPİ BUZDOLABI............................................ INO-SBP246*TEZGAH TİPİ BUZDOLABI............................................ INO-SBP140*TEZGAH TİPİ BUZDOLABI............................................ INO-SBP190*TEZGAH TİPİ BUZDOLABI............................................ INO-SBP240

Page 6: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

4

Page 7: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

5

MERMER TABLALI TEZGAH TİPİ BUZDOLABI*TEZGAH TİPİ BUZDOLABI............................................ INO-SBM146*TEZGAH TİPİ BUZDOLABI............................................ INO-SBM196*TEZGAH TİPİ BUZDOLABI............................................ INO-SBM246*TEZGAH TİPİ BUZDOLABI............................................ INO-SBM140*TEZGAH TİPİ BUZDOLABI............................................ INO-SBM190*TEZGAH TİPİ BUZDOLABI............................................ INO-SBM240

EVİYELİ PRES TABLALI TEZGAH TİPİ BUZDOLABI*TEZGAH TİPİ BUZDOLABI............................................ INO-SBE146*TEZGAH TİPİ BUZDOLABI............................................ INO-SBE196*TEZGAH TİPİ BUZDOLABI............................................ INO-SBE246*TEZGAH TİPİ BUZDOLABI............................................ INO-SBE140*TEZGAH TİPİ BUZDOLABI............................................ INO-SBE190*TEZGAH TİPİ BUZDOLABI............................................ INO-SBE240

Page 8: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

6

Page 9: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

7

*INO-XS-KCT - CAM KAPI*INO-XS-T - TEKERLEK

*INO-XS-C712 ÇEKMECE, 700mm TEZGAH TİPİ BUZDOLABI 1/2*INO-XS-C612 ÇEKMECE, 600mm TEZGAH TİPİ BUZDOLABI 1/2*INO-XS-C713 ÇEKMECE, 700mm TEZGAH TİPİ BUZDOLABI 1/3*INO-XS-C613 ÇEKMECE, 600mm TEZGAH TİPİ BUZDOLABI 1/3*INO-XS-C723 ÇEKMECE, 700mm TEZGAH TİPİ BUZDOLABI 2/3*INO-XS-C623 ÇEKMECE, 600mm TEZGAH TİPİ BUZDOLABI 2/3

Page 10: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

8

 

 

 

Page 11: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

9

INO-XS-KCT - Cam kapı/Glass Door/ Стеклянная дверь

Page 12: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

10

*INO-XS-C712 ÇEKMECE, 700mm Tezgah Tipi Buzdolabı için ½

INO-XS-C712 TYRE, 700mm COUNTER TYPE REFRIGERATOR ½

INO-XS-C712 ЯЩИК,700ммХОЛОДИЛЬНИК ПРОМЫШЛЕННЫЙ СО СТОЛЕШНИЦЕЙ1/2

*INO-XS-C612 ÇEKMECE, 600mm Tezgah Tipi Buzdolabı için ½

INO-XS-C612 TYRE, 600mm COUNTER TYPE REFRIGERATOR ½

INO-XS-C612 ЯЩИК,600ммХОЛОДИЛЬНИК ПРОМЫШЛЕННЫЙ СО СТОЛЕШНИЦЕЙ1/2

*INO-XS-C713 ÇEKMECE, 700mm Tezgah Tipi Buzdolabı için 1/3

INO-XS-C713 TYRE, 700mm COUNTER TYPE REFRIGERATOR 1/3

INO-XS-C713 ЯЩИК,700ммХОЛОДИЛЬНИК ПРОМЫШЛЕННЫЙ СО СТОЛЕШНИЦЕЙ1/3

*INO-XS-C613 ÇEKMECE, 600mm Tezgah Tipi Buzdolabı için 1/3

INO-XS-C613 TYRE, 600mm COUNTER TYPE REFRIGERATOR 1/3

INO-XS-C613 ЯЩИК,600ммХОЛОДИЛЬНИК ПРОМЫШЛЕННЫЙ СО СТОЛЕШНИЦЕЙ1/3

*INO-XS-C723 ÇEKMECE, 700mm Tezgah Tipi Buzdolabı için 2/3

INO-XS-C723 TYRE, 700mm COUNTER TYPE REFRIGERATOR 2/3

INO-XS-C723 ЯЩИК,700ммХОЛОДИЛЬНИК ПРОМЫШЛЕННЫЙ СО СТОЛЕШНИЦЕЙ2/3

*INO-XS-C623 ÇEKMECE, 600mm Tezgah Tipi Buzdolabı için 2/3

INO-XS-C623 TYRE, 600mm COUNTER TYPE REFRIGERATOR 2/3

INO-XS-C623 ЯЩИК,600ммХОЛОДИЛЬНИК ПРОМЫШЛЕННЫЙ СО СТОЛЕШНИЦЕЙ2/3

 

Page 13: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

11

*TEZGÂH TİPİ BUZDOLABI/COUNTER TYPE REFRIGERATOR/ ХОЛОДИЛЬНИК ПРОМЫШЛЕННЫЙ СО СТОЛЕШНИЦЕЙ

- INO-SBN146

- INO-SBM146

- INO-SBP146

- INO-SBE146

 

Page 14: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

12

 

*TEZGÂH TİPİ BUZDOLABI/COUNTER TYPE REFRIGERATOR/ ХОЛОДИЛЬНИК ПРОМЫШЛЕННЫЙ СО СТОЛЕШНИЦЕЙ

- INO-SBN196

- INO-SBM196

- INO-SBP196

- INO-SBE196

Page 15: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

13

*TEZGÂH TİPİ BUZDOLABI/COUNTER TYPE REFRIGERATOR/ ХОЛОДИЛЬНИК ПРОМЫШЛЕННЫЙ СО СТОЛЕШНИЦЕЙ

- INO-SBN246

- INO-SBM246

- INO-SBP246

- INO-SBE246

 

Page 16: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

14

 

*TEZGÂH TİPİ BUZDOLABI/COUNTER TYPE REFRIGERATOR/ ХОЛОДИЛЬНИК ПРОМЫШЛЕННЫЙ СО СТОЛЕШНИЦЕЙ

- INO-SBN140

- INO-SBM140

- INO-SBP140

- INO-SBE140

Page 17: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

15

*TEZGÂH TİPİ BUZDOLABI/COUNTER TYPE REFRIGERATOR/ ХОЛОДИЛЬНИК ПРОМЫШЛЕННЫЙ СО СТОЛЕШНИЦЕЙ

- INO-SBN240

- INO-SBM240

- INO-SBP240

- INO-SBE240

 

Page 18: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

16

*TEZGÂH TİPİ BUZDOLABI/COUNTER TYPE REFRIGERATOR/ ХОЛОДИЛЬНИК ПРОМЫШЛЕННЫЙ СО СТОЛЕШНИЦЕЙ

- INO-SBN190

- INO-SBM190

- INO-SBP190

- INO-SBE190

 

Page 19: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

17

INO-XS-C712 ÇEKMECE, 700mm Tezgah Tipi Buzdolabı için 1/2

INO-XS-C612 ÇEKMECE, 600mm Tezgah Tipi Buzdolabı için 1/2

INO-XS-C713 ÇEKMECE, 700mm Tezgah Tipi Buzdolabı için 1/3

INO-XS-C613 ÇEKMECE, 600mm Tezgah Tipi Buzdolabı için 1/3

INO-XS-C723 ÇEKMECE, 700mm Tezgah Tipi Buzdolabı için 2/3

INO-XS-C623 ÇEKMECE, 600mm Tezgah Tipi Buzdolabı için 2/3

 

Page 20: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

18

PASLANMAZ TABLALI TEZGAH TİPİ BUZDOLAPLARI TEKNİK ÖZELLİKLER

MODELMODELS

İÇ SICAKLIKTEMPERATURE

°C

KAPASİTECAPACITY

Lt

GÜÇ POWER

kw

ÖLÇÜLER DIMENSIONS ( H*D*W cm )

PAKET ÖLÇÜSÜ PACKING DIM.

cm

AĞIRLIKWEIGHT

kg

İNO-SBN146 -2 / +8 250 0,30 850x600x1400 900x650x1440 110

İNO-SBN196 -2 / +8 400 0,30 850x600x1865 900x650x1900 150

İNO-SBN246 -2 / +8 550 0,61 850x600x2335 900x650x2370 190

İNO-SBN140 -2 / +8 280 0,30 850x700x1400 900x750x1440 120

İNO-SBN190 -2 / +8 465 0,30 850x700x1865 900x750x1900 165

İNO-SBN240 -2 / +8 640 0,61 850x700x2335 900x750x2370 205

POLİETİLEN TABLALI TEZGAH TİPİ BUZDOLAPLARI TEKNİK ÖZELLİKLER

MODELMODELS

İÇ SICAKLIKTEMPERATURE

°C

KAPASİTECAPACITY

Lt

GÜÇ POWER

kw

ÖLÇÜLER DIMENSIONS ( H*D*W cm )

PAKET ÖLÇÜSÜ PACKING DIM.

cm

AĞIRLIKWEIGHT

kg

İNO-SBP146 -2 / +8 250 0,30 850x600x1400 900x650x1440 120

İNO-SBP196 -2 / +8 400 0,30 850x600x1865 900x650x1900 160

İNO-SBP246 -2 / +8 550 0,61 850x600x2335 900x650x2370 200

İNO-SBP140 -2 / +8 280 0,30 850x700x1400 900x750x1440 130

İNO-SBP190 -2 / +8 465 0,30 850x700x1865 900x750x1900 180

İNO-SBP240 -2 / +8 640 0,61 850x700x2335 900x750x2370 220

MERMER TABLALI TEZGAH TİPİ BUZDOLAPLARI TEKNİK ÖZELLİKLER

MODELMODELS

İÇ SICAKLIKTEMPERATURE

°C

KAPASİTECAPACITY

Lt

GÜÇ POWER

kw

ÖLÇÜLER DIMENSIONS ( H*D*W cm )

PAKET ÖLÇÜSÜ PACKING DIM.

cm

AĞIRLIKWEIGHT

kg

İNO-SBM146 -2 / +8 250 0,30 850x600x1400 900x650x1440 170

İNO-SBM196 -2 / +8 400 0,30 850x600x1865 900x650x1900 210

İNO-SBM246 -2 / +8 550 0,61 850x600x2335 900x650x2370 250

İNO-SBM140 -2 / +8 280 0,30 850x700x1400 900x750x1440 180

İNO-SBM190 -2 / +8 465 0,30 850x700x1865 900x750x1900 220

İNO-SBM240 -2 / +8 640 0,61 850x700x2335 900x750x2370 265

Page 21: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

19TR

EVİYELİ PRES TABLALI TEZGAH TİPİ BUZDOLAPLARI TEKNİK ÖZELLİKLER

MODELMODELS

İÇ SICAKLIKTEMPERATURE

°C

KAPASİTECAPACITY

Lt

GÜÇ POWER

kw

ÖLÇÜLER DIMENSIONS ( H*D*W cm )

PAKET ÖLÇÜSÜ PACKING DIM.

cm

AĞIRLIKWEIGHT

kg

İNO-SBE146 -2 / +8 250 0,30 850x600x1400 900x650x1440 170

İNO-SBE196 -2 / +8 400 0,30 850x600x1865 900x650x1900 210

İNO-SBE246 -2 / +8 550 0,61 850x600x2335 900x650x2370 250

İNO-SBE140 -2 / +8 280 0,30 850x700x1400 900x750x1440 180

İNO-SBE190 -2 / +8 465 0,30 850x700x1865 900x750x1900 220

İNO-SBE240 -2 / +8 640 0,61 850x700x2335 900x750x2370 265

• Dijital termometre ve termostat - otomatik defrost vardır.

• Fanlısoğutmavardır.

• İçgövdepaslanmazçeliktir.

• Dışgövdedegözükenyerlerpaslanmazçeliktir.

• HCFC Free 45 kg/m³ yoğunlukta poliüretanizolasyonludur.

• Yüksekliğiayarlanabilirpaslanmazçelikraftutucularmevcuttur.

• Temizlenebilir ve yerinden sökülebilir manyetikcontalıdır.

• Özelkapıveyaylımenteşesistemimevcuttur.

• İçaydınlatmavardır.

• Şıkveergonomikdizaynlıdır.

• Yüksekliği ayarlanabilir paslanamaz özel ayaklarmevcuttur.

• SoğutmaGazı:R404A/R134A

• Dışortamsıcaklığı:+43°Cdir.

• Çalışmavoltajı:220-230V50Hz.

AMAÇ VE KULLANIM• Bu buzdolapları restoran, bar, market ve büyükmutfaklarda et ve süt ürünlerini, sebze, pasta vediğer yiyecek-içecekleri soğuk olarak depolamakiçintasarlanmıştır.

• Gerek cihazın gerekse kullanıcısının herhangi birzarargörmemesiiçincihazıbunundışındabiramaçiçinkullanmayınız.

• Üreticifirma;

• Cihazın yukarıda belirtilen amacı dışındakullanılmasından veya eğitim almamış kişilertarafındançalıştırılmasındandolayı,

• Yanlışmontajdandolayı,

• Yetersiztemizlikvebakımdandolayı,

• Yetkili teknisyenler tarafından yapılmayan bakımveyateknikmüdahalelerdendolayı,

• Orijinalyedekparçakullanılmamasındandolayı,

• Kullanım kılavuzuna uymadan yapılan herhangi birişlemdendolayı,

İnsanlara, hayvanlara veya eşyalara karşı meydanagelebileceknihaizararlardansorumlulukkabületmez.

Bu cihazların; patlayıcı ve yangın riskinin bulunduğuortamlarda, kötü hava şartlarının olduğu ortamlarda(temiz hava bulunmayan, yağ ve toz oranının yüksekolduğuyerlerde)kullanımıuygundeğildir.

GENEL ÖNLEMLER• Eğer çevrede küçük çocuklar varsa cihazı çalışırdurumdayadakapılarınıkilitlemedenbırakmayınız.

• Çalışır durumdaki cihaza ıslak ve nemli el yadaçıplakayakiledokunmayınız.

Page 22: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

20

• Ekovat içindekisoğutucugazzehirlideğildir,ancakyinedeyutulmamalıdır.

• Suluyemeklerinmuhafazasıbuğuoluşumunasebepolabilir. Bu durum cihazın normal çalışmasınıetkilemez.

• Koruyucu kapakların altına veya dönen aksamınarasınatornavidavb.aletlerikesinliklesokmayınız.

• Cihazda temizlik, yer değiştirme, bakım yadaonarım faaliyetine başlamadan önce mutlaka anaşalteri kapatınız ve cihaz fişini prizden çekiniz.Soğutma sisteminde ozon tabakasına zarar verenCFC(kloroflorokarbon)gazınıiçermeyenR134aveyaR404Afreongazıkullanılmaktadır.

TAŞIMA VEYA YERİNDEN OYNATMA• Buzdolapları taşınırken mutlaka ambalajındagösterildiği gibi dik durumda ve kendilerine hasargelmeyecekşekildetaşınmalıdır.

• Ürünler taşınacak yer ve uzaklığa göre, müşteriisteğinebağlıolarakpaketliyadapaketsizgidebilir.Paketler mukavva + strech film yada buna ilaveolarakahşapkafesliolabilir.

• Yükleme ve taşıma mutlaka transpalet veya forkliftileyapılmalıdır.

• Yükleme ve indirme sırasında ürüne gelebilecekhasarlargarantikapsamındadeğildir.

MONTAJ• Cihazıyeterlihavalandırmanınyapılabildiğibiryereyerleştiriniz.

• Cihaz üzerindeki koruyucu naylonu sıyırarakçıkarınız. Yüzey üzerinde yapışkan madde artıklarıkalırsa uygun bir çözücü ile temizleyeniz (örneğinHenkel-Helios).

• Cihazıdüzgünbirzeminüzerineayarlanabilirayaklarıvasıtasıileteraziyealarakyerleştiriniz.

• Sugirişveatıksuhattını(eğervarsa)bağlayınız.

• Cihazınızı soba, fırın, ocak, kalorifer gibi ısıkaynaklarından koruyunuz. Bu mümkün değilsebelirtilenısıkaynaklarındanenaz50cmuzakbiryere

cihazıyerleştiriniz.

• Yetersiz soğutmadan dolayı yiyeceklerin bozulmariski nedeni ile cihazı direkt güneş ışığına maruzbırakmayınız.

• Cihazın soğutma ünitesi mutlaka rahat havaalabileceği(havaakımınıengellemeyecek)biryerdeolmalıdır.

ELEKTRİK BAĞLANTISI• Cihaz 220-230V 50-60Hz şebeke gerilimindenbeslenmelidir.

• Kablo kesiti maksimum akımı taşıyacak kesitteseçilmelidir.

• Voltajtoleransı±%10’ugeçmemelidir.

• Cihaz mutlaka topraklanmalıdır. Topraklamayapılmadan kullanma durumunda üretici firma hiçbirsorumlulukkabuletmez.

• Ani elektrik kesintilerinde veya prizi fişe takıpçıkarmalarda soğutma sistemindeki gazın basıncıhenüz dengelenmemiş olduğu için cihazınızınsisteminezararverebilir.Butürolaylarakarşıdikkatliolunmalı ve bu tür olaylardan doğacak arızalarıngarantikapsamıdışındakalacağıbilinmelidir.

KULLANIMCihaz profesyonel kullanım için tasarlanmıştır vesadece bu konuda eğitim almış kişiler tarafındankullanılmalıdır.

6.1. Çalıştırma öncesi

• Montajsırasındacihazabirhasargelipgelmediğinikontrolediniz.

• Kontrol panelinin, elektrik kablolarının vebağlantılarınınhasarsızvedoğruyapıldığındaneminolun.

• Adaptör, birden fazla fiş ve ekleme bağlantılarıüstündenkesinliklecihazaelektrikvermeyiniz.

• Cihazın soğutma ünitesi önündeki havalandırmadeliklerininkapalıolmadığındaneminolunuz.

• Cihazınızı ilk çalıştırma öncesi en az 1 saat

Page 23: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

21

bekleyiniz. Böylece nakliye ve taşıma esnasındasisteme karışmış yağ tekrar kompresöre geridönecektir.

• Cihaz maksimum +430C dış ortam sıcaklığı ve%60 bağıl nem koşulları altında çalışacak şekildetasarlanmıştır.

• Yukarıdaki şartlara uyum sağlanamadığı takdirdeürünün çalışma performansında ciddi kayıplarortayaçıkacak,ekovatınerkenyıpranmasınaveaşırıenerjikaybınasebebiyetverecektir.

6.2. Isı dereceleri

• Soğutmakabini içinde tutulacakolanürününcinsi,dış ortam sıcaklığı ve kapı açma sıklığı cihazınçalışmaperformansınıdirektetkiler.

• Eksi derecede çalışan buzdolapları sadecedondurulmuş olan ürünlerin uzun süre muhafazasıiçinkullanılır.

6.3. Yemeklerin yerleştirilmesi

• Buzdolabına yemekleri yerleştirmeden öncesoğutma kabininin çalışma sıcaklığına ulaşmasıbeklenmelidir.

• Soğutma kabini içine sıcak yemek veya üstü açıksıvıkoymayınız.

• Bütünyemeklerinüstünümutlakakapatınız.

• Ürünleri yerleştirirken içerdeki hava akımınınengellenmemesinedikkatediniz.

• Cihazkapısınıuzunsüreaçıkbırakmayınız.

6.4. Cihazın çalıştırılması

• Cihazfişinitopraklıprizetakınız.

• Açma-kapamadüğmesiilecihazınızıçalıştınız.

• Cihazınız rejime girinceye kadar kapaklarınıaçmayınız.

• Kontrolpanelindekisoğutmakontrolcihazıvasıtasıileistediğinizdereceyecihazınızıayarlayınız.

6.5. Cihazın kapatılması

• Açma-kapamadüğmesini“Off”konumagetiriniz.

• Elektrikfişiniprizdençekiniz.

TEMİZLİK ve BAKIM • Cihazdatemizlikyadabakımfaaliyetinebaşlamadanöncemutlakacihazfişiniprizdençekiniz.

• Cihazı temizlemek için ılık suya batırılmış bezve kokusuz, yiyeceklere zarar vermeyen tipte birtemizleyici(deterjan)kullanınız.

• Asla cihazın iç yada dış yüzeylerine zararverebilecek aşındırıcı içeriği olan deterjanlar veyaçizikyapabilecektelfırçalarkullanmayınız.

• Temizlemeişlemindensonrasıcaksu iledurulayıpyumuşakbirbezlekurulayınız.Cihazıniçikuruyanakadarkapılarınıaçıkbırakınız.

• Fan motorunun en çok 15 günde bir yağlanmasıgerekmektedir.(Bulunduğu ortama göre bu süredahakısadatutulabilir).Kondenservefanmotorununbakımınınyapılmamasıcihazınverimliliğinidüşürürveekovatınyanmasınasebepolabilir.

• Buzdolabının evaparatöründeki (soğutucu petek)aşırıkarlanma(buzlanma)cihazınveriminidüşürücüve problem yaratıcı bir unsurdur. Cihazınızınuzun ömürlü ve verimli olabilmesi için karlanmaoluştuğundacihazıdefrost(eritme)yaptırınız.

• Cihazı direkt veya yüksek basınçlı su iletemizlemeyiniz. Aksi halde elektrik tesisatınınarızasınanedenolabilirsiniz.

• Cihazda tehlikeli bir durum görülmesi halinde,yetkiliservisehaberveriniz. (Başvurunuzdacihazınyan tarafında etikette yazılı olan seri numarası vemodelini özellikle belirtiniz.) Ehliyetsiz kişilerincihaza müdahale etmesine izin vermeyiniz. Aksitakdirdecihazınızgarantidışıkalacaktır.

• Bunun yanında sizin yapmakla yükümlü olduğunuzbakım işlemlerini yapmamanızdan kaynaklananarızalarınbakımveonarımıücretetabidir.

• Cihaz eğer uzun süre çalıştırılmayacaksa elektrikbağlantısınıkesiniz,içindekiyiyecekleridışarıalınız,oksitlemeye karşı korumak için gıda maddelerinezarar vermeyen bir dezenfektan ile tüm yüzeyitemizleyiniz,küf,kötükokuveoksitlenmeyiönlemekiçinkapılarınıaçıkbırakınız,tozakarşıkorumakiçinüstünüörtünüz.

Page 24: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

22

MUHTEMEL PROBLEMLER ve ÇÖZÜMLERPROBLEM MUHTEMEL SEBEPLER MUHTEMEL ÇÖZÜMLER

Cihazaenerjigelmiyor.

Cihazfişiprizetakılmamıştır. Fişi,prizetakınız.

Enerjigirişkablosuarızalı/kesiktir. Kontrolediniz/yetkiliservisçağırınız.

Cihazınanaşalterikapalıdır. Anaşalteriaçınız.

Kontrolpanelineenerjigelmiyordur. Kontrolediniz/yetkiliservisçağırınız.

Açma-kapamadüğmesikapalıdır. Açma-kapamadüğmesiniaçınız.

Cihazyeterikadar

soğutmuyor.

Soğutmaderecesidoğru

seçilmemiştir.

Soğutmaderecesinikontroledip

gerekiyorsadereceyiyükseltiniz.

Cihazbirısıkaynağı(ocak,fırınvs.)

yakınınayerleştirilmişyadadirekt

güneşışığınamaruzkalıyordur.

“MONTAJ”bölümündetanımlandığıgibicihazıısıkaynağındanvedirekt

güneşışığındanuzaktutunuz.

Havalandırmadelikleritıkanmıştır. Havalandırmadelikleriniaçınız.

Kondenserkirlenmiştir. Kontrolediniz/temizleyiniz.

Soğutmaçevrimindekiherhangibir

yerdekopma/kesilmeolmuşturyada

soğutmagazıbitmiştir.

Kontrolediniz/yetkiliservisçağırınız.

Evaparatöraşırıkarlanmıştır.Evaparatörünkarlarınıneritiniz

(defrost)

Cihazınbulunduğuortamsıcaklığı

aşırıfazladır.

Ortamsıcaklığınıkontroledinizve

mümkünsedüşürünüz.

Cihazaşırıfazlasoğutuyor.Soğutmaderecesidoğru

seçilmemiştir.

Soğutmaderecesinikontroledip

gerekiyorsadereceyidüşürünüz.

Aydınlatmaçalışmıyor.

Cihazfişiprizetakılmamıştır. Fişi,prizetakınız.

Enerjigirişkablosuarızalı/kesiktir. Kontrolediniz/yetkiliservisçağırınız.

Cihazınanaşalterikapalıdır. Anaşalteriaçınız.

KONDENSER TEMİZLİĞİ Kondenser üzerinde biriken tozlar cihazın verimli birşekilde çalışmasını engelleyeceği ve sıcaklığı arttırıpmotorun arıza yapmasına sebep olacağı için için15 günde bir yumuşak bir fırça (tel fırça kesinliklekullanmayınız) veya elektrikli süpürge ile kondenserüzeriveçevresinintozunutemizleyiniz.

Page 25: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

23

BAZI BESİNLERİN DEPOLAMA SICAKLIKLARI VE SÜRELERİ

BESİN SICAKLIK ( C ) SÜRE

Et 0 ÷ 2 3-5gün

Kıyma 0 ÷ 2 1-2gün

Balık -1 ÷ 0 1-2gün

Yumurta 4 ÷ 7 1hafta

Pastörizesüt 3 ÷ 4 1gün

Yumuşakmeyve 4 ÷ 7 2gün

Sertmeyve 4 ÷ 7 2hafta

Yeşilsebze 4 ÷ 7 5gün

Diğersebze 4 ÷ 7 2hafta

Dondurulmuşgıda -18 ÷ -22

0

Kontrolpanelineenerjigelmiyordur. Kontrolediniz/yetkiliservisçağırınız.

Aydınlatmadüğmesikapalıdır. Aydınlatmadüğmesiniaçınız.

Flouresantampularızalıdır. Kontrolediniz/yetkiliservisçağırınız.

Ekovatçalışmıyor.

Prizeenerjigelmiyordur. Kontrolediniz.

Soğutmakontrolcihazıkapalıdır. Kontrolediniz/açınız.

Kondenserfanıçalışmıyordur. Yetkiliservisçağırınız.

Diğer Yetkiliservisçağırınız.

Ekovatgürültülüçalışıyor.

Kondenserkirlenmiştir. Kontrolediniz/temizleyiniz.

Fanmotoruarızalıdır. Yetkiliservisçağırınız.

Diğer Yetkiliservisçağırınız.

Cihazdefrostyapmıyor.

Soğutmakontrolcihazındadefrost

ayarıyapılmamıştır.Kontrolediniz.Defrostayarıyapınız.

Soğutmakontrolcihazıarızalıdır. Yetkiliservisçağırınız.

Diğer Yetkiliservisçağırınız.

Page 26: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

24

TABLE TYPE REFRIGERATOR TECNICAL DATA

MODELMODELS

İÇ SICAKLIKTEMPERATURE

°C

KAPASİTECAPACITY

Lt

GÜÇ POWER

kw

ÖLÇÜLER DIMENSIONS ( H*D*W cm )

PAKET ÖLÇÜSÜ PACKING DIM.

cm

AĞIRLIKWEIGHT

kg

İNO-SBN146 -2 / +8 250 0,30 850x600x1400 900x650x1440 110

İNO-SBN196 -2 / +8 400 0,30 850x600x1865 900x650x1900 150

İNO-SBN246 -2 / +8 550 0,61 850x600x2335 900x650x2370 190

İNO-SBN140 -2 / +8 280 0,30 850x700x1400 900x750x1440 120

İNO-SBN190 -2 / +8 465 0,30 850x700x1865 900x750x1900 165

İNO-SBN240 -2 / +8 640 0,61 850x700x2335 900x750x2370 205

POLYETHYLENE TRAY TABLE TYPE REFRIGERATORS TECNICAL DATA

MODELMODELS

İÇ SICAKLIKTEMPERATURE

°C

KAPASİTECAPACITY

Lt

GÜÇ POWER

kw

ÖLÇÜLER DIMENSIONS ( H*D*W cm )

PAKET ÖLÇÜSÜ PACKING DIM.

cm

AĞIRLIKWEIGHT

kg

İNO-SBP146 -2 / +8 250 0,30 850x600x1400 900x650x1440 120

İNO-SBP196 -2 / +8 400 0,30 850x600x1865 900x650x1900 160

İNO-SBP246 -2 / +8 550 0,61 850x600x2335 900x650x2370 200

İNO-SBP140 -2 / +8 280 0,30 850x700x1400 900x750x1440 130

İNO-SBP190 -2 / +8 465 0,30 850x700x1865 900x750x1900 180

İNO-SBP240 -2 / +8 640 0,61 850x700x2335 900x750x2370 220

MARBLE TOP COUNTER TYPE REFRİGERATORS TECNICAL DATA

MODELMODELS

İÇ SICAKLIKTEMPERATURE

°C

KAPASİTECAPACITY

Lt

GÜÇ POWER

kw

ÖLÇÜLER DIMENSIONS ( H*D*W cm )

PAKET ÖLÇÜSÜ PACKING DIM.

cm

AĞIRLIKWEIGHT

kg

İNO-SBM146 -2 / +8 250 0,30 850x600x1400 900x650x1440 170

İNO-SBM196 -2 / +8 400 0,30 850x600x1865 900x650x1900 210

İNO-SBM246 -2 / +8 550 0,61 850x600x2335 900x650x2370 250

İNO-SBM140 -2 / +8 280 0,30 850x700x1400 900x750x1440 180

İNO-SBM190 -2 / +8 465 0,30 850x700x1865 900x750x1900 220

İNO-SBM240 -2 / +8 640 0,61 850x700x2335 900x750x2370 265

GB

Page 27: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

25

TABLE BENCH PRESS SİNK REFRIGERATORS TECNICAL DATA

MODELMODELS

İÇ SICAKLIKTEMPERATURE

°C

KAPASİTECAPACITY

Lt

GÜÇ POWER

kw

ÖLÇÜLER DIMENSIONS ( H*D*W cm )

PAKET ÖLÇÜSÜ PACKING DIM.

cm

AĞIRLIKWEIGHT

kg

İNO-SBE146 -2 / +8 250 0,30 850x600x1400 900x650x1440 170

İNO-SBE196 -2 / +8 400 0,30 850x600x1865 900x650x1900 210

İNO-SBE246 -2 / +8 550 0,61 850x600x2335 900x650x2370 250

İNO-SBE140 -2 / +8 280 0,30 850x700x1400 900x750x1440 180

İNO-SBE190 -2 / +8 465 0,30 850x700x1865 900x750x1900 220

İNO-SBE240 -2 / +8 640 0,61 850x700x2335 900x750x2370 265

• Digital thermometer & thermostat - automaticdefrost

• Ventilatedcoolingsystem

• İnteriorstainlesssteel

• Appearexteriorsurfaceofstainlesssteel

• 45 kg/m³ density ecology friendly (CFC Free)polyurethaneisolation

• Plasticcoatedsteelshelves(Dim:54x32,5cm)

• Adjustablestainlesssteelshelfholders

• Removableandeasycleaningmagneticgaskets

• Specialdoorandhingesdesign

• İnterionlighting

• Specialandergonomicdesign

• Adjustablefeet

• Coolinggas:R404A/R134A

• Ambienttemperature:+43°C

• Workingvoltage:220-230V50Hz.

First of all, we would like to congratulate you for your choice. We kindly present this manual to enable you to utilize your refrigerator most effi-ciently.

Before starting to use your refrigerator, please read carefully this manual and keep at a safe place for further reference when necessary.

INSTALLATION• Mountyourapplianceonasmoothsurface,ensuringtheequilibriumwiththehelpofadjustablefeet.

• Connect the water feed andwaste water dischargeline(ifany).

• Place your appliance at a sufficient distance awayfromheatsourcessuchasstove,furnace,radiatorsandsunlight.

ELECTRICAL CONNECTIONS• Theapplianceshouldbesuppliedwiththe1N220VAC50Hzmainsvoltage.

• Theselectedcable’scross-sectionshouldallowtheflowofmaximumcurrent.

• Voltagetoleranceshouldnotexceed±10%.

• Theapplianceshouldstrictlybeearthed.Incaseofoperatingtheappliancewithoutproperearthing,ourcompanywillinnowaywhatsoeverbeheldliable.

• In case of immediate electrical cut-offs or plug-ins/plug-outs, your appliance’s system may bedamaged due to the unbalanced gas pressure inthe refrigerating system. Sufficient care should beobservedagainstsuchcasesanditshouldbenotedthatfailurestoariseoutofsuchcasesshallbeoutofthewarrantycoverage.

Page 28: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

26

OPERATION• Waitfor1hourbeforestartingyourappliance.Inthisway, the oil that hasmixed into the systemduringtransportorhandlingwillreturntothecompressor.

• Connecttheappliance’splugintoearthedsocket.

• Startyourappliancewiththeswitchon-offbutton.

• Start the fan if your appliance is forcedly coolingmechanism.

• Do not open the lids until the humidity amount isdroppeddowntoastablelevel.

• Setthedesiredtemperaturedigitalthermometre.

• Yourappliancehasbeendesigned tooperateatanambienttemperatureof+43oC,relativehumidityof60% and at a temperature range of -2/+80C. Anyotherambientconditionmaygiverise toefficiencylosses.

CLEANING AND MAINTENANCE• Always plug-out the appliance before starting anycleaningormaintenancework.

• A clean cloth immersed into warm soapy water isadequatetocleanthedevice.

• Donotuseabrasivedetergentsorwirebrushesthatmayscratchthesurfaceoranyothersimilarmaterialandapplianceofsuchnatureduringcleaning.

• You can employ chemical solvents to clean toughstains on the surface that cannot be removed bymeansoftheabovementionedmethods.

• Dust the condenser surface and its vicinityperiodically as dust depositing on the condensermayhindertheefficientoperationofthedevice.

• The fan motor should be lubricated on a 15-daybasis at most (This periodmay be less accordingtotheoperatingenvironmentofthedevice).Failureto effect maintenance on the condenser and fanmotorreducestheoperatingefficiencyofthedeviceand may further give rise to the burn-out of thecondenser.

• Excessive frosting in refrigerator’s evaporator

(chillingchamber)isanadversefactorthatreducesthe operating efficiency of the device and leads tofurtherproblems.Toensurealonglifeofthedevice,strictlyeffectdefrostingwheneveranyfrostoccurs.

• Avoid cleaning the device with direct or high-pressure water jet; otherwise your electricalinstallationmaybebrokendown.

• Incaseyounoticeanyriskyconditioninthedevice,immediately call the authorized technical service(please specify especially the serial number andmodelinformationinscribedonthelabelattachedtotheedgeof thedevice).Donotallowunauthorizedpeople to effect any operation on the device;otherwiseitwillfalloutofthewarrantycoverage.

• Inaddition,maintenanceorrepairofanymalfunctionarisingoutofyourfailuretosatisfythemaintenanceworkunderyourliabilitywillbechargedseparately.

TROUBLESHOOTINGThe appliance fails to refrigerate:

• Checkthethermostat’scurrentrefrigeratingpositionandincreaseitifnecessary.

• Checkthatthecondenserunitisclean.Removeanydustanddirtfromthisunit.

• Theevaporatormayexcessivelybefrosted.Plugouttheapplianceandallowdefrosting.

• Incasetheapplianceisdirectlyexposedtosunlight,itmayfailtofulfiltherefrigerationprocessperfectly.Changeyourappliance’slocation.

• Ifambienttemperatureexceeds+43oC,thedevicecannot operate normally. Check the ambienttemperature.

• If the appliance fails to refrigerate even after theabove mentioned remedies are satisfied, contactwiththeauthorizedtechnicalservice.

The appliance fails to run automatically:

• Check the thermostat switch. Turn it on and off. Ifthermostatrunsproperly,thefailurestemsfromanyothercause.

• Check the cleanliness of the condenser unit. If

Page 29: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

27

necessary, remove contaminants such as dust andoil from the surface of the condenser. Check theproperoperationof the fanmotor. If rotationof thefanmotor is not sufficient, demount the fanmotorandlubricateit.

• If theproblemprevails,contactwith theauthorizedtechnicalservice.

The condenser fails to run:

• Check the availability of the power supply in thesocket.

• Checkwhetherthethermostatswitchisonoroff.

• Checkwhether thecondenser’schilling fanrunsornot.

• If all units and functions operate properly but thecondenser is still out of work, contact with theauthorizedtechnicalservice.

The condenser gives out unusual noise:

• Checkthecleanlinessofthecondenser.Removeanddustanddirt.

• Effecttheperiodicalmaintenanceofthefanmotor.

If the failure still prevails, contactwith theauthorizedtechnicalservice

POSSIBLE ERRORS AND REMEDIES ERROR POSSIBLE CASUSES POSSIBLE REMEDIES

Equipmentisnotpowered.

Itisnotplugged. Plugin/calltheauthorizedservice.

Powerinletcableisoutoforder/cut Check/calltheauthorizedservice..

Main switch of the equipment isturnedoff.

Turnonthemainsswitch/callthe

authorizedservice.

Controlboardisnotenergized. Check/calltheauthorizedservice..

On/offbuttonisturnedoff. Turnontheon/offbutton.

Equipmentdoesnotcool

enough.

Coolingtemperatureisnotselected

correctly.

Checkthecoolingtemperatureand,if

necessary,increasethetemperature.

Equipmentispositionednearaheat

source(cooker,ovenetc.)orbeing

exposedtodirectly.

Asdefinedin“INSTALLATION”

chapter,keepawaytheequipment

fromthesourceofheatanddirect

sunlight..

Ventilationholesareobstructed. Opentheventilationholes.

Condenserisdirty. Check/clean.

Inthecoolingcycle,thereisa

discjucture/cutatanypointorthe

coolinggasfinished.

Calltheauthorizedservice..

Evaporatorhasexcessfrostdeposit. Performadefrostcycle.

Ambienttemperatureistoohigh.Checktheambienttemperatureand,

ifpossible,reduce.

Page 30: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

28

Equipmentcoolstoomuch.Coolingtemperatureisnotselected

correctly.Checkthecoolingtemperatureand,ifnecessary,decreasethetemperature.

Equipmentdoesnot

illuminate.

Itisnotplugged. Plugin./calltheauthorizedservice.

Powercableisoutoforder/cut. Check/calltheauthorizedservice..

Mainsswitchisturnedoff. Turnonthemainsswitch.

Controlboardisnotenergized. Check/calltheauthorizedservice..

Illuminationbuttonisturnedoff.. Turnontheilluminationbutton.

Flourescantlampisoutoforder. Check/calltheauthorizedservice..

Refrigeratormotordoesnot

operate.

Socketisnotenergized. Check.

Coolingcontroldeviceisturnedoff. Check/turnon.

Condenserfandoesnotwork. Calltheauthorizedservice..

Other Calltheauthorizedservice.

Refrigeratormotoroperates

noisy.

Condenserisdirty. Check/clean.

Fanmotorisoutoforder. Calltheauthorizedservice..

Other Calltheauthorizedservice.

Equipmentdoesnotdefrost.

Defrost adjustment is not done onthecoolingcontroldevice. Check.Adjustdefrost.

Cooling control device is out oforder. Calltheauthorizedservice..

Other Calltheauthorizedservice..

STORAGE TEMPERATURES AND PERIODS OF SOME FOODS

FOOD TEMPERATURE ( C ) PERIOD

Meat 0 ÷ 2 3-5days

Mincedmeat 0 ÷ 2 1-2days

Fish -1 ÷ 0 1-2days

Egg 4 ÷ 7 1week

Pasteurizedmilk 3 ÷ 4 1day

Softfruit 4 ÷ 7 2days

Hardfruit 4 ÷ 7 2week

Greenvegetables 4 ÷ 7 5days

Othervegetables 4 ÷ 7 2week

Frozenfood -18 ÷ -22

0

Page 31: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

29

ХОЛОДИЛЬНИКИ ПРОМЫШЛЕННЫЕ СО СТОЛЕШНИЦЕЙ ИЗ НЕРЖАВЕЮЩЕЙ СТАЛИТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ

МОДЕЛЬ ВНУТРЕННЯЯ

ТЕМПЕРАТУРА

°C

ЕМКОСТЬл

МОЩНОСТЬ

кВтРАЗМЕРЫВ*Г*Ш см

РАЗМЕРЫ УПАКОВКИ

см

ВЕСкг

İNO-SBN146 -2 / +8 250 0,30 850x600x1400 900x650x1440 110

İNO-SBN196 -2 / +8 400 0,30 850x600x1865 900x650x1900 150

İNO-SBN246 -2 / +8 550 0,61 850x600x2335 900x650x2370 190

İNO-SBN140 -2 / +8 280 0,30 850x700x1400 900x750x1440 120

İNO-SBN190 -2 / +8 465 0,30 850x700x1865 900x750x1900 165

İNO-SBN240 -2 / +8 640 0,61 850x700x2335 900x750x2370 205

ХОЛОДИЛЬНИКИ ПРОМЫШЛЕННЫЕ СО СТОЛЕШНИЦЕЙ ИЗ ПОЛИЭТИЛЕНАТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ

МОДЕЛЬ ВНУТРЕННЯЯ

ТЕМПЕРАТУРА

°C

ЕМКОСТЬл

МОЩНОСТЬ кВт

РАЗМЕРЫВ*Г*Ш см

РАЗМЕРЫ УПАКОВКИ

см

ВЕСкг

İNO-SBP146 -2 / +8 250 0,30 850x600x1400 900x650x1440 120

İNO-SBP196 -2 / +8 400 0,30 850x600x1865 900x650x1900 160

İNO-SBP246 -2 / +8 550 0,61 850x600x2335 900x650x2370 200

İNO-SBP140 -2 / +8 280 0,30 850x700x1400 900x750x1440 130

İNO-SBP190 -2 / +8 465 0,30 850x700x1865 900x750x1900 180

İNO-SBP240 -2 / +8 640 0,61 850x700x2335 900x750x2370 220

ХОЛОДИЛЬНИКИ ПРОМЫШЛЕННЫЕ СО СТОЛЕШНИЦЕЙ ИЗ МРАМОРАТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ

МОДЕЛЬ ВНУТРЕННЯЯ

ТЕМПЕРАТУРА

°C

ЕМКОСТЬл

МОЩНОСТЬ кВт

РАЗМЕРЫВ*Г*Ш см

РАЗМЕРЫ УПАКОВКИ

см

ВЕСкг

İNO-SBM146 -2 / +8 250 0,30 850x600x1400 900x650x1440 170

İNO-SBM196 -2 / +8 400 0,30 850x600x1865 900x650x1900 210

İNO-SBM246 -2 / +8 550 0,61 850x600x2335 900x650x2370 250

İNO-SBM140 -2 / +8 280 0,30 850x700x1400 900x750x1440 180

İNO-SBM190 -2 / +8 465 0,30 850x700x1865 900x750x1900 220

İNO-SBM240 -2 / +8 640 0,61 850x700x2335 900x750x2370 265

Page 32: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

30

ХОЛОДИЛЬНИКИ ПРОМЫШЛЕННЫЕ СО СТОЛЕШНИЦЕЙ-МОЙКОЙТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ

МОДЕЛЬ ВНУТРЕННЯЯ

ТЕМПЕРАТУРА

°C

ЕМКОСТЬл

МОЩНОСТЬ кВт

РАЗМЕРЫВ*Г*Ш см

РАЗМЕРЫ УПАКОВКИ

см

ВЕСкг

İNO-SBE146 -2 / +8 250 0,30 850x600x1400 900x650x1440 170

İNO-SBE196 -2 / +8 400 0,30 850x600x1865 900x650x1900 210

İNO-SBE246 -2 / +8 550 0,61 850x600x2335 900x650x2370 250

İNO-SBE140 -2 / +8 280 0,30 850x700x1400 900x750x1440 180

İNO-SBE190 -2 / +8 465 0,30 850x700x1865 900x750x1900 220

İNO-SBE240 -2 / +8 640 0,61 850x700x2335 900x750x2370 265

• Цифровой термометр и термостат - функцияавтоматическогоразмораживания.

• Охлаждениевентиляторноготипа.

• Внутреннийкорпусизнержавеющейстали.

• Видимые части наружного корпуса изнержавеющейстали.

• Изоляция -полиуретанплотностью45 кг/м³,несодержащийГХФУ(гидрохлорфторуглероды).

• Держатели для стальных полок, позволяющиерегулироватьвысотуполки.

• Моющиесяисъемныемагнитныеуплотнения.

• Специальная система пружинных петель испециальныхдверей.

• Внутренняяподсветка.

• Роскошныйиэргономичныйдизайн.

• Особые ножки из нержавеющей стали,позволяющиерегулироватьвысотуагрегата.

• Газ-хладагент:R404A/R134A

• Температуранаружнойсреды:+43°C.

• Рабочеенапряжение:220-230В50Гц.

1. ЦЕЛЬ И НАЗНАЧЕНИЕ• Холодильник предназначен для хранения

в охлажденном виде мясных и молочных

продуктов, овощей, тортов и других продуктовпитания и напитков и предусматриваетиспользованиевресторанах,барах,маркетахипромышленныхкухнях.

• Сцельюпредупрежденияповрежденияагрегатаипользователей,неразрешаетсяиспользоватьагрегатвдругихцелях.

• Фирма-производительненесетответственности:

• За использование агрегата в других целях, заисключением вышеуказанных, или введениев эксплуатацию лицами, не имеющимиквалификации,

• Занеправильныймонтаж;

• За неисправности, возникающие в результатенедостаточнойочисткиитехобслуживания,

• За неисправности, возникающие в результатетехобслуживания или технического ремонта,выполненного другими лицами, за исключениетехничеcкихсотрудников;

• За неисправности, возникшие в результатеиспользования не оригинальных запасныхчастей;

• За неисправности, возникшие в результателюбых действий, выполненных с нарушениеминструкцийруководствапоэксплуатации;

• За нарушения, возникающие в связи свозможнымущербомдлялюдей,животныхили

Page 33: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

31

собственности.

• Данный агрегат не предназначен дляиспользования в средах с риском возгоранияили взрывоопасных средах, в средах сплохими условиями воздуха (не имеющихпритока свежего воздуха, с высоким уровнемсодержанияпылиимасла).

2. ОСНОВНЫЕ МЕРЫ ПРЕДОСТОРОЖНОСТИ• Если в окружении присутствуют дети, не

оставляйте агрегат во включенном состоянииилиснезакрытымидверями.

• Избегайте контакта мокрыми или влажнымирукамиилиобнаженныминогамисвключеннымагрегатом.

• Газ-хладагентвнутри компрессоранеявляетсяядовитым, вместе с этим избегайте попаданиягазавовнутрьорганизма.

• Хранение продуктов питания в жидком видемогут стать причиной образования водяногопара. Данное обстоятельство не повлияет наработуагрегата.

• Категорическизапрещаетсявсовыватьотверткии т.п. инструменты под защитные крышкиили между вращающимися комплектующимиагрегата.

• Передвыполнениемочистки,измененияместа,техобслуживания или ремонта, обязательноотключите главный выключатель агрегата иотсоедините вилку кабеля электропитанияагрегатаизрозетки.

• В охладительной системе агрегатаиспользуетсяфреоновыйгазR134aилиR404A,не содержащий ХФУ (хлорфторуглерод) иявляющийся безопасным для озонового слояатмосферы.

3. ТРАНСПОРТИРОВКА ИЛИ ИЗМЕНЕНИЕ МЕСТА УСТАНОВКИ• Вовремятранспортировкиагрегатаобязательно

соблюдайте указания, указанные на упаковке,и обеспечьте вертикальное положение ипредупреждение возможного поврежденияагрегата.

• Продукцию разрешается транспортироватьв упаковке или без упаковки в зависимостиот пожеланий клиента, места назначения идальности транспортировки. Упаковка можетбыть в виде картона + стрейч пленка или,дополнительно, в деревянном решетчатомящике.

• Погрузка и транспортировка обязательнодолжна выполняться на паллете или припомощивилочногопогрузчика.

• В гарантию на продукцию не включеныповреждения, возникающие во время погрузкииразгрузки.

4. МОНТАЖ• Разместите агрегат в месте с возможностью

обеспечениядостаточнойвентиляции.

• Аккуратно снимите с агрегата защитнуюнейлоновую пленку. Если на поверхностиостанутсяостаткиклеящеговещества,очиститеповерхность при помощи соответствующегорастворителя(например,Henkel-Helios).

• При помощи регулируемых ножек выполнитенивелирование агрегата, размещенного наровноеоснование.

• Подключите трубопроводводыи сточнойводы(еслиимеются).

• Предохраняйте агрегат от таких источниковтеплакакпечь, кухоннаяплита,духовойшкаф,радиаторы отопления. Если это невозможно,разместите агрегат в месте, находящемся нарасстояниинеменее50смотисточникатепла.

• В связи с опасностью порчи продуктов в связиснедостаточнымохлаждением,неразмещайтеагрегат в местах с попаданием прямыхсолнечныхлучей.

• Блок охлаждения агрегата установите такимобразом, чтобыобеспечитьбеспрепятственное

Page 34: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

32

поступлениевоздуха.

5. ЭЛЕКТРОСОЕДИНЕНИЯ• Агрегатработаетотсетевогоэлектроснабжения

220-230В50-60Гц.

• Сечение кабеля должно соответствоватьсечению,способномувыдержатьмаксимальнуюнагрузкуэлектротока.

• Отклонение напряжения от номинального недолжнопревышать±10%.

• Обязательно обеспечьте заземление агрегата.Фирма-производитель не несет какой-либоответственности в связи с эксплуатациейагрегатабеззаземления.

• В случае неожиданных отключенийэлектропитанияиливовремявключениявилкиврозетку, возможновозникновениеповрежденийсистемыагрегата,ввидунесбалансированностидавления газа в системе. В данных случаяхследует соблюдать осторожность инеобходимознать,чтонеисправностиагрегата,возникающие в подобных случаях, не входятв рамки гарантийного обязательства фирмы-производителя.

6. ЭКСПЛУАТАЦИЯ• Агрегат предусмотрен для профессионального

использованияидолжениспользоватьсятолькоквалифицированными лицами, получившимисоответствующееобучение.

6.1. Перед включением.

• Вовремямонтажаагрегатапроверьтеналичиеповреждений.

• Убедитесь в отсутствии повреждений иправильном подключении панели управления,электрическогокабеляисоединений.

• Не подключайте электропитание агрегатачерез адаптер несколькими розетками и черезудлинитель.

• Убедитесь, что открыты вентиляционныеотверстия впереди холодильного блока

агрегата.

• Передпервымвключениемагрегатавыждитенеменее 1 часа. Таким образом, обеспечиваетсявозвратмасла,попадающеговсистемувовремятранспортировки и перемещения, обратно вкомпрессор.

• Агрегат предусматривает условия работы примаксимальной температуре наружного воздуха+430Cиотносительнойвлажностивоздуха60%.

• Вслучаееслинесоблюдаютсявышеуказанныеусловия-этоможетстатьпричинойсерьезногоснижения рабочих показателей агрегата,раннего износа компрессора и чрезмернойпотериэлектроэнергии.

6.2. Температуры

• Видпродуктов,предназначенныхдляхранениявнутри камеры охлаждения, температуранаружной среды и частота открытия дверейимеют прямое воздействие на рабочиепоказателиагрегата.

• Холодильники, работающие с отрицательнойтемпературой, предназначены только длядолговременного хранения замороженныхпродуктов.

6.3. Размещение продуктов питания

• Перед размещением продуктов питанияв холодильник необходимо выждать ихпредварительного охлаждения до рабочейтемпературыкамеры.

• Запрещается помещать внутрь холодильнойкамеры горячую пищу или жидкости внезакрытыхемкостях.

• Обязательно следует закрывать сверху всепродуктыпитания.

• При размещении продуктов питания обратитевнимание на предупреждение препятствий длявентиляциивоздуха.

• Не оставляйте на продолжительный срокоткрытымидверикамерыагрегата.

Page 35: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

33

6.4. Включение агрегата

• Вставьте вилку электропитания агрегата врозеткусзаземлением.

• Нажатием на кнопку включено-выключено,включитеагрегат.

• Неоткрывайтекрышкиагрегатадотехпор,покаагрегатненачнетработатьврабочемрежиме.

• При помощи устройства контроля процессаохлаждения на панели правления, установитежелаемуютемпературуагрегата.

6.5. Отключение агрегата

• Нажатием на кнопку включено-выключено,переключите агрегат в состояние выключено/”Off”/.

• Отсоедините вилку кабеля электропитания изрозетки.

7. УХОД И ТЕХОБСЛУЖИВАНИЕ • Перед выполнением очистки или

техобслуживания, обязательно отсоединитевилку кабеля электропитания агрегата изрозетки.

• Очистку агрегата выполните при помощитряпки,смоченнойвтеплойводе,иочищающегосредства,беззапахаиневредногодляпищевыхпродуктов.

• Категорически запрещается использовать дляочистки абразивные чистящие средства илиметаллические щетки, способные поцарапатьнаружныеивнутренниеповерхностиагрегата.

• Послепроцедурыочисткипромойтеповерхностигорячей водой и высушите при помощи мягкойтряпки. Оставьтеоткрытымидверидополноговысыханиявнутреннихповерхностейагрегата.

• Электродвигатель вентилятора требует смазкине более чем каждые 15 дней. (В зависимостиот среды данный срок может быть сокращен).Невыполнение техобслуживания конденсатораи электродвигателя вентилятора может статьпричиной снижения производительностиагрегатаиперегораниякомпрессора.

• Чрезмерное образование обледенения наиспарителе холодильника (охладительногозмеевика) является причиной сниженияпроизводительности агрегата и может статьпричиной для возникновения проблем. Дляобеспечения длительного срока службыи производительности агрегата, в случаевозникновения обледенения выполнитеразмораживаниеагрегата.

• Запрещается выполнять очистку агрегатапри помощи прямой струи воды или воды поднапором.Впротивномслучае,этоможетстатьпричинойповрежденияэлектросоединений.

• В случае возникновения опасной ситуации вработеагрегата,обратитесьвавторизированнуютехслужбу. (При оформлении запроса натехобслуживание, укажите серийный номер имодельагрегата,указанныенабоковойпанели).Неразрешайтевмешиватьсявработуагрегатанесанкционированным лицам. В противномслучае, гарантийное обеспечение агрегатабудетсчитатьсянедействительным.

• Вместе с этим, техобслуживание и ремонтпо устранению неисправностей агрегата,возникших по причине невыполнениятехобслуживания, подлежащие выполнениюпользователем, осуществляются за отдельнуюплату.

• Еслиагрегатнебудетиспользоватьсявтечениедлительного периода времени, отключитеэлектропитание агрегата, выньте продуктыпитания из камеры, с целью предупрежденияокисления,очиститевсеповерхностичистящимсредством,невреднымдляпищевыхпродуктов;сцельюпредупрежденияобразованияплесени,плохих запахов и окисления, оставьте двериагрегата открытыми; с целью предупрежденияпопаданияпыли,накройтеагрегат.

8. ОЧИСТКА КОНДЕНСАТОРА • В вид того, что пыль, скапливаемая на

конденсаторе, является причиной сниженияпроизводительности агрегата и причинойповышения температуры электродвигателя,вызывающей неисправность двигателя, один

Page 36: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

34

раз в 15 дней выполните очистку пыли сконденсатораивокругконденсатораприпомощимягкой щетки (не используйте металлическующетку)илиприпомощиэлектропылесоса.

ВОЗМОЖНЫЕ ПРОБЛЕМЫ и ИХ РЕШЕНИЯПРОБЛЕМА ВОЗМОЖНЫЕ ПРИЧИНЫ ВОЗМОЖНЫЕ РЕШЕНИЯ

Вагрегатнепоступаетэлектропитание.

Невставленавилкаэлектропитанияагрегатаврозетку.

Вставьтевилкуврозетку.

Неисправен/разорванкабельэлектропитания.

Проверьте/вызовитеавторизированнуютехслужбу.

Отключенглавныйвыключательагрегата.

Включитеглавныйвыключательагрегата.

Непоступаетэлектропитаниевпанельуправления.

Проверьте/вызовитеавторизированнуютехслужбу.

Выключенакнопкавключено-выключено.

Включитекнопкувключено-выключено.

Агрегатневыполняетдостаточноеохлаждение.

Температураохлажденияустановленаневерно.

Проверьтетемпературуохлажденияи,еслитребуется,установитеправильнуютемпературу.

Агрегатустановленвблизиисточникатепла(печи,духовогошкафаит.п.)илиподверженвлияниюпрямыхсолнечныхлучей.

Установитеагрегатвдалиотисточниковтеплаипрямыхсолнечныхлучей,согласноуказанномувразделе"МОНТАЖ".

Закупоренывентиляционныеотверстия.

Откройтевентиляционныеотверстия.

Загрязненконденсатор. Проверьте/очистите.Возникобрыв/обрезвкаком-либоместеконтураохлажденияилизакончилсягаз-хладагент.

Проверьте/вызовитеавторизированнуютехслужбу.

Чрезмерноеобледенениеиспарителя.Разморозьтеобледенениеиспарителя.

Чрезмерновысокаятемпературасредыместонахожденияагрегата.

Проверьтетемпературусредыи,есливозможно,снизьтетемпературу.

Page 37: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

35

Агрегатвыполняетчрезмерноеохлаждение.

Температураохлажденияустановленаневерно.

Проверьтетемпературуохлажденияи,еслитребуется,установитеправильнуютемпературу.

Не работаетподсветка.

Невставленавилкаэлектропитанияагрегатаврозетку.

Вставьтевилкуврозетку.

Неисправен/разорванкабельэлектропитания.

Проверьте/вызовитеавторизированнуютехслужбу.

Отключенглавныйвыключательагрегата.

Включитеглавныйвыключательагрегата.

Непоступаетэлектропитаниевпанельуправления.

Проверьте/вызовитеавторизированнуютехслужбу.

Выключенакнопкаподсветки. Включитекнопкуподсветки.

Неисправнафлуоресцентнаялампа.Проверьте/вызовитеавторизированнуютехслужбу.

Неработаеткомпрессор.

Непоступаетэлектропитаниеврозетку. Проверьте.

Отключеноустройствоконтроляохлаждения.

Проверьте/включите.

Неработаетвентиляторконденсатора.Вызовитеавторизованнуютехслужбу.

ДругиеВызовитеавторизованнуютехслужбу.

Компрессорработаетсшумом.

Загрязненконденсатор. Проверьте/очистите.Неисправенэлектродвигательвентилятора.

Вызовитеавторизованнуютехслужбу.

ДругиеВызовитеавторизованнуютехслужбу.

Агрегатневыполняетразмораживание.

Невыполненанастройкаразмораживаниявустройствеконтроляохлаждения.

Проверьте.Выполнитенастройкуразмораживания.

Неисправноустройствоконтроляохлаждения.

Вызовитеавторизованнуютехслужбу.

ДругиеВызовитеавторизованнуютехслужбу.

Page 38: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

36

ТЕМПЕРАТУРА И СРОКИ ХРАНЕНИЯ НЕКОТОРЫХ ПРОДУКТОВ ПИТАНИЯПРОДУКТ ТЕМПЕРАТУРА ( 0C ) СРОК

Мясо 0 ÷ 2 3-5 днейФарш 0 ÷ 2 1-2 днейРыба -1 ÷ 0 1-2 днейЯйцо 4 ÷ 7 1 неделиПастеризованноемолоко 3 ÷ 4 1 днейМягкиефрукты 4 ÷ 7 2 днейТвердыефрукты 4 ÷ 7 2 неделиЗеленыеовощи 4 ÷ 7 5 днейДругиеовощи 4 ÷ 7 2 неделиЗамороженныепродуктыпитания -18 ÷ -22

Page 39: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

37

Page 40: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

38

MARMARA

BÖLGESİSERVİSİNADI ADRESİ TELEFONVEFAKS

ADAPAZARI ALPTEKNİK

OsmanALTINTAŞ

GüneyMobilyacılar

San.Sitesi294Sk.

UluyolNo:13

Erenler,SAKARYA

Tel264.2758709

Fax.264.2813594

532.6670577

BALIKESİR ERTEKNİK

ErolERDOĞAN

Yıldırım

Mah.AkarSokak

No:30

BALIKESİR

Tel.266.2456227

Fax.266.2395130

538.7245151Birol

555 314 48 94 Erol

5352943510Fuat

BURSA

GAZTEKNİK

NecdetATICI

KurtuluşCad.No:27

Yıldırım,BURSA

Tel.224.3260960

Fax.224.3270701

NecmiBey,

533.5576376

GÜLEÇYÜZTEKNİK

SeydiGÜLEÇYÜZ

SakaryaMah.Düz

SokakNo:17

BURSA

Tel.224.2710310

Fax.224.2711940

532.2711599

SeydiGüleçyüz

530 224 12 15

METTEKNİKLTD.

ŞTİ.

MesutTayır

YeniYalovaYolu

KüplüpınarMh.

No:91/BBursa

Tel..224.2726969

Faks224.2720819

532.7227748

PİRTEKNİK

MustafaPİR

HacivatMh.145

Sk.No:17

Yıldırım,BURSA

Tel.224.3421780

Faks.2243423698

532.7991946

SATIŞSONRASIHİZMETLERMÜDÜRLÜĞÜYETKİLİSERVİSLİSTESİ

OrganizeSanayiBölgesiOrmanlarCaddeNo:516159BURSA

Tel.224.2947474Fax.224.2433667

[email protected]

Page 41: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

39

İNOKSTEKNİK

İbrahimGÖYÖZ

Kırcaalimah.

Anafartalarsok.No:1/A

OSMANGAZİBURSA

Tel.224.8880050

Faks..224.8880051

532 578 88 18

İBRAHİM-

533.5636709

UMUT

+99365080617-

BANDIRMA BAŞARITEKNİK

-EsinUlunç/Fatih

Kırmızıgül

500EvlerAtatürk

Cd.No:15/A

Tel266.7213000

0 532 43242 77

ÇANAKKALEGÜÇ-KAY

ELEKTRİK

UğurKAYA

İsmetpaşaMah.Aynalı

ÇeşmeSok.No:25

ÇANAKKALE

Tel.286.2175189

286.2133146

Fax.2862130085

532.4512564

İSTANBUL

BATIYAKASI

AKTEKNİK

MuhammetALTINAY

BahriyeCd.YağHanesi

Sk..No:50

Kasımpaşa,İSTANBUL

Tel.212.2541793

Fax.212.2549532

533.6112050

BUZ-PAN

MÜH.LTD.ŞTİ.

İsmail

KÜÇÜKMEHMETOĞLU

BahriyeCad.No:105/A

(AkbankYanı)

Kasımpaşa,İSTANBUL

Tel.212.2566156

Fax.212.2539668

533.2479220

NUR-MANKLİMA

HalilŞEN

ÇobançeşmeMah.Fatih

Cad.

HalitpaşaSok.No:47

Yenibosna,İSTANBUL

Tel.212.6531741

Fax.212.6390940

532.2964215

UMUTSER

LTD.ŞTİ.

BayramYÜKSEL

EskiBayramyeriSokak,

No:5/A

Kasımpaşa,İSTANBUL

Tel.212.2536766

Fax.212.2536766

532.4360494

Page 42: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

40

AVSERTEKNİKHİZ.

TİC.LTD.ŞTİ.

ÜniversiteMh.Uran

Cd.KöşkSk.No:23

Avcılar/İstanbul

212.6945901-02

212.6945955

0533 305 54 37

ERSİN

0533 924 48 05

KEMAL

EFESTEKEND.

MUTF.SAN.VE

TİC.LTD.ŞTİ.

FatihKIRMIZIGÜL

AltayÇeşmeMh.

PapatyaÇıkmazıBüke

Apt.Dükkan:34

Maltepe/İSTANBUL

216 441 29 50

216 441 29 51

216.4412952faks.

5544249168Fatih

GastrosanEnd.

Mutfak

ÇamaşırhaneEkip.

San.Tic.Ltd.Şti

YahyaKütükçü

GöztepeMahallesi

SadırvanSokak

HasanogluApt.No7/A-

Bagcılar-İstanbul

Tel.212.4944688

Fax.212.4944689

0554 872 75 75

0532 314 94 72

ÖZDEMİRTEKNİK

TunaÖZDEMİR

BağlarBaşıMah.Şehit

TurhanSelviSok.No:3

CMaltepe/İstanbul

Tel.02163991724

Fax.2164412652

05372787974

İST.ANADOLU

YAKASI

MNMMAKİNE

METAL

MehmetUSLU

MustafapaşaMah.

ŞehiŞehitÖmürErgül

Cad.No:7

GeGebze,Kocaeli

Tel.262.6418428–

262.6436084

Fax.262.6436083

532.2022568

YÖNSERLTD.ŞTİ.

İsmetBAĞLAMA

ÖrnekMah.4.Sokak,

No:4

Üsküdar,İSTANBUL

Tel.216.31799

94/95

Fax.216.3179993

CihatBey:

532 599 76 20

Page 43: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

41

TUNERKLİMA

YavuzTUNER

NevzatBulutSk.

AdaletApt.No.14

Dükkan:1

Kozyatağı/İSTANBUL

Tel.021637399

03- 04

Fax.3739901

0 533 545 85 86

YavuzTuner

İZMİT

BERİLTEKNİK

MecitDİLBER

İnönüCad.KozlukMah.

No:7/DİZMİT

Tel..262.3324586

Fax.2623324588

532.2009653

Mecitbey

ÖZTÜRKTEKNİK

CihanÖZTÜRK

KadıköyMah.Bağdat

Cad.ReşitpaşaSokak

No:28

İZMİT/KOCAELİ

Tel.262.3212133

Fax.262.3212148

CEP:05338188572

TRAKYA

BÖLÜMÜÇORLU EMİNTEKNİK

ZiyaÖZYER

KazımiyeMah.Cahit

SıtkıTarancıCd.Sema

Apt.NO:4ÇORLU

Tel.2826735897

Fax.2826735497

Ziyabey

05392617250

ERTEKNİK

EnverERDOĞAN

ReşadiyeMh.Atatürk

Cd.FatmaÖzkanApt.

No:40ÇORLU

Tel.282.6541716

Fax.282.6527217

535.4391077

EnverBey

EGEBÖLGESİ SERVİSİNADI ADRESİ TELEFONVEFAKS

AFYON

BUZTEKNİK

HüseyinKUMRU

CumhuriyetMah.Ömer

FevziCad.GökApt.

AFYON

Tel.272.2159014

Fax.272.2132175

532.3741513

AYBERTİCARET

MevlütAYBER

CumhuriyetMah.

C.AhmetpaşaCad.

No:9/AAFYON

Tel.2722157171

Fax..2722157373

555.9818128

Page 44: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

42

BODRUM DENEYİMTEKNİK MevlütAYBER

CumhuriyetMah.

C.AhmetpaşaCad.

No:9/AAFYON

Tel.2722157171

Fax..2722157373

555.9818128

ASLANTEKNİK MetinBayramArslan

UmurçaMah.Yaka

Sk.No:1/A

BODRUM

Tel.252.3169442

Faks.252.3160637

MetinAslan

5396974805

DENİZLİ KAR-SAN

SOĞUTMA

MuammerKURU

HürriyetCad.Baysal

Apt.No:14DENİZLİ

Tel.258.2659020

Fax.258.2659021

532.2164018

Muammer

FETHİYE STARTEKNİK TancurKOCAMAN

SanayiSitesiDoğuBlok

İnançEkmekFab.Yanı

FETHİYE

252 611 04 75/

612 37 31

Fax..252.6140179

252.6140178

532.2532270

MARMARİS MARMARİSTEK.

SER.HİZ.TUR.TİC.

LTD.ŞTİ.

HüseyinAKTUĞ

ÇıldırMh.

128SokakNo:19

MARMARİS

Tel.252.4121170

Fax.252.4121171

532.6642427

MAKSER ORHANDABAN

TepeMahYeniyolCad

NO:53/DMARMARİS

Tel.252.4122939

Fax.252.4122939

0 532 507 39 12

İZMİR İBERKOLTD.ŞTİ. ErkanTAŞÇAKAR

4326SokakAkçay

Cd.No:2/1

İzmirİnoksanMağaza

ÜstüKarabağlar,İZMİR

Tel.

232.2647652-53

Fax.2322647693

532 475 48 13

Page 45: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

43

DETAYTEKNİK

KasımYILMAZ

4327Sok.No:17

Karabağlar

Konak,İZMİR

Tel.232.2640267-

264 02 66

Fax.2640277

532.4091783-

533 6602080

AKSERLTD.ŞTİ.

ArifTAVŞANCI

4328SokakNo:40/A

Karabağlar/İzmir

0232 265 28 94

0232 254 68 28

532.4573166

ASTEKNİK

MuratGARİP

AkdoğanCad:No:8A

Şirinyer/İzmir

Tel.232.4874240

Fax232.4874246

532.4262813

KUŞADASI DELTATEKNİK

AtillaKUZU

CumhuriyetMah.

SüleymanDemirel

Bulvarı12-B-C

Kuşadası,AYDIN

Tel.256.6148422

Fax.256.6126099

542.4537432

KÜTAHYA

LİDERTEKNİK

Semaİşsiz

MeydanMh.M.Paşa

Cd.YakutSit.No:94/A

Kütahya

274.2123722

274.2234656

543.3231329

ÇINARISITMA

SOĞUTMA

FerhatŞeyhan

YunusemreMh.

Yunusemre

Cd.No:53Kütahya

274.2716154

541 453 22 86

NAZİLLİ EFESOĞUTMA

LeventTerzioğlu

YeniMahalleOrdu

Cd.No:78/A

Nazilli/Aydın

256 312 01 88 -

312 38 18

Fax.256.3153113

LeventBey.

535.2163806

İÇANADOLU

BÖLGESİSERVİSİNADI ADRESİ TELEFONVEFAKS

Page 46: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

44

ANKARA

HİSARTİCARET

YaşarUğurlu

HarbiyeMah.

NadirSok.No:12/A

Dikmen,Ankara

Tel/Fax.312.48051

35

ŞükrüUğurlu

537 204 08 60

TEKNOSERLTD.

ŞTİ.

CaferÇAKAR

İlkadımMh.Dayanışma

Sk.N:12/CDikmen,

ANKARA

Tel.312.4784046

Fax.478.4047

533.6356536

ARMADAMUT.

SAN.TİC.LTD.ŞTİ

SadıkÇINAR

GençlikCaddesi

No:19/B

Tandoğan-Ankara

Tel.312.2324237-

78-89

Fax.312.2318976

5323373094

SEVİNOKSMUT.

SAN.TİC.LTD.ŞTİ.

SadıkAKGÜN

AkıncılarK.19/10-11

Maltepe/ANKARA

Tel.312.2324238

Fax.312.2324258

5332769789

AR-TEKSTEKNİK

RüstemGÜNDOĞDU

TuzluçayırMh.597

Sk.1/A

Mamak/ANKARA

Tel.312.3676212

Fax.312.3676264

541.3165125

AydınBey

537 676 15 62

RüstemBey

ESKİŞEHİR

ANADOLUTEKNİK

İbrahimGAŞ

HayriyeMh.Zübeyde

HanımCd.No:38/C

Eskişehir

Tel.222.2331866

Fax.222.2341186

YILDIZTEKNİK

DavutKURT

MamureMahallesi

Hasan Polatkan Caddesi

YücelenSokokNo:11/A

Tepebaşı/ESKİŞEHİR

Tel.

0(222)2201069

Fax.

0(222)2201049

0 532 374 07 53

Davut

Page 47: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

45

ISPARTAFRİGONTERMM

SOĞT.

MustafaKIRALGAZ

İskenderMh.121Cad.

No:40/2ISPARTA

Tel..246.2186838

Fax.2462326938

532.2579650

KAYSERİ

KOÇLARTİCARET

YılmazKOÇLAR

MimarSinanMh.Tuna

Cd.Tuna2Apt.No:43/A

Kocasinan,KAYSERİ

Tel.352.2361841

Fax.352.2361853

535.4837990

555.3169725

VERKAN

SOĞUTMA

CelilTEMİZKAN

FatihMh.NilCd.

No:2/C

Kocasinan,KAYSERİ

Tel.352.2312823

Fax.352.2221630

532.4041277

507 260 49 77

KONYA

ÖZELBOBİNAJ

SeferÖZEL

SultanVeledCad.

SarayApt.Altı,No:26/B

KONYA

Tel.332.3516301

532.6071927

FOREVDAYANIKLI

SAN.TİC.LTD.ŞTİ.

ToptancılarSitesi

1.Blok(KuleSite)

ArkasıSelçuklu/Konya

ZaferBey.

0541 831 49 43

Tel.0332.2332899

Faks.

0332.2356031

HasanBey

0 555 981 89 16

AKSARAY GÜVENSOĞUTMA

MikailKOYUNCU

MuhsinÇelebiMh.

1NoluSk.AKSARAY

Tel.382.2132289

Fax.382.2138898

535.4584748

SİVAS

YEŞİLKİMYASAĞ.

ÜRÜN.SAN.TİC.

LTD.ŞTİ.

MuratDOĞANÇAY

ToptancılarSitesi

19.Blk..NO.58SİVAS

Tel.3462263500

Fax.3462262035

532.3673355

ENDÜSTRİ

TEMİZLİK

MustafaKARTAL

HikmetIşıkCd.Erdoğan

Apt.AltıNo:11SİVAS

Tel.346.2245844

Fax.3462245841

542.5413099

AKDENİZ

BÖLGESİSERVİSİNADI ADRESİ TELEFONVEFAKS

Page 48: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

46

ADANA

MAHMUTNİHAT

ÖZTÜRK-

KROMSAN

TEKNİKSERV.

YurtMah.A.TürkeşBlv.

No:78/BADANA

Tel.03222669161

0 322 225 37 10

0 532 317 56 80

BARANMUTFAK

FevziPaşaMh.Turhan

CemalBeriçerBlv.

No:280Seyhan,ADANA

Tel.3224215010

05336914951–

CenkSondur

ANTALYA

ANTİNOKS

LTD.ŞTİ.

TurgayDOĞANTEKİN

SedirMh.GaziBlv.

No:122/A

KepezBelediyesiYanı

ANTALYA

Tel.242.3345963

Fax.242.3348156

532.4749302

YILDIZLAR

LTD.ŞTİ.

MuratYILDIZ

AkdenizYeniSanayi

Sitesi5007Sk.No:25

ANTALYA

Tel.242-2215359

–5953

Fax.242.2215669

542.4374804

ANTSEREND.

MUT.ISIT.

SOĞUTMASİS.

SelimBAYER

UlusMh.OrhanVeliCd.

HayfaBarutApt.No:25

D:2ANTALYA

Tel.2423342970

Fax.2423342870

YücelBAYER

5323657631

SelimBAYER

532 798 60 22

ALANYA

ALANYAMUTFAK

İbrahimÇALIŞ

SugözüMah.

Develiler Sk,

ŞenApt.No:2/A

TedaşYanıALANYA

Tel.242.5226018

Fax.242.5226017

5327058879

SEKTÖRMUTFAK

Bahçelievlermahallesi

5002sokakno:16/A

BurhanÖzApartmanı

MANAVGAT

Tel.02427433093

Faks.02427467566

iş:05309730880

VeliDOLU:

0532 705 88 79

Page 49: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

47

MERSİN KAPELLTD.ŞTİ.

AliKaplan

KiremithaneMh.

CengiztopelCd

No:54/BMersin

Tel.3242385552

Fax.3242384727

532.3310895

ANTAKYA

GLOBAL

İKLİMLENDİRME

TİC.LTD.ŞTİ.-

SERVİS

RüstemTümerpaşa

Cad.

SözerApt.AltıNo:29/

A-BANTAKYA

Tel.326.2122762

Fax.326.2146408

BATI-ORTA

KARADENİZ

BÖLÜMÜ

SERVİSİNADI ADRESİ TELEFONVEFAKS

SAMSUN MAKİNETEKNİK

CemilLAKOT

FevziÇakmakMah.

TayfunSok.No:2

SAMSUN

Tel.362.2308319

Faks.362.2317406

532.5524166

KASTAMONUÇAĞDAŞBEYAZ

EŞYA

DavutUYGUN

CebrailMh.SimsarSk.

KastamonuGazt.Yanı

No:1/AKASTAMONU

Tel.366.2124411

Fax.366.2128744

532.4300383

0 5411726

DOĞU

KARADENİZ

BÖLÜMÜ

SERVİSİNADI ADRESİ TELEFONVEFAKS

TRABZON

MERKEZSERVİS

H.TuranAlemdağ

GülbaharHatunMah.

YavuzSelimBulvarı

No:54/BTrabzon

Tel.462.2303744

Fax.462.2301081

532.3716152

ÇAĞLARTEKNİK

OsmanLAKOT

FatihMh.

AyasofyaCd.No:22

TRABZON

462.2309885

462.2309885

532.3831148

Page 50: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

48

NRLTD.ŞTİ.

İskenderpaşaMah.

İdealSok.No:13/A

TRABZON

462.2814141

462.2814142

0533 611 73 74

ORDUORTEKEND.MKN.

LTD.ŞTİ.

MustafaÇİÇEK

KarşıyakaMh.

AtatürkBlv..No:122

ORDU

452.2347234

452.2333106Fax

535.4834553

541.5408148

RİZEAKMANLAR

TEKNİK

DavutAKMAN

CumhuriyetCad

No/286RİZE

Tel.4642132995

Fax.4642140651

542.2424534

DOĞU

ANADOLU

BÖLGESİ

SERVİSİNADI ADRESİ TELEFONVEFAKS

ELAZIĞ AKTİFSERVİS

VeyselKARAKAYA

İzzetpaşaMh.Hacı

TevfikEfendiSok.

No:25/BELAZIĞ

Tel.Fax.

424 236 77 33

532.5412401

ERZURUM

ÇAĞDAŞYAŞAR

TEK.

NecdetYAŞAR

GezMahallesiKazım

KarabekirCd.EskiSgk

İlMüdürlüğüKarşısı

No:12ERZURUM

Tel.442.2131990-

13 27

Fax.442.2132057

533.3075501

KAFKASTİCARET

SuatBurakMidilliç

KongreCd.Demirciler

ÇarşısıNo.2Erzurum

Tel.442.2133959

bayi

442.2133640

442.2341112

servis

Fax.442.2133959

MALATYA PETEKSERTEKNİK

MustafaPOLAT

NiyaziMh.3.Sokak

TopçuoğluApt.Altı

MALATYA

Tel.422.3215700

Fax.422.3251089

532.3426269

Page 51: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

49

ÖRENELK.YAPI

İNŞ.SUÜRÜN.LTD.

ŞTİ.

MuhammedÖREN

İlyasMh.Sanayi

Cd.No:51MALATYA

Tel.422.2118477

Fax.422.2118407

0544 979 99 91

VANÖMERFARUK

ALPAY

AlipaşaMah.

UrartuCad.No:46/A

VAN

432.2157717

432.2157717

539.3134389

ÖmerBey

IĞDIR GÜVENTEKNİK

FeyzullahGÜREL

TopçularMh.Topçular

Cd.UmurApt.No:46/

IĞDIR

Tel.476.2271656

Fax.476.2271656

0535 2272222

VahitBey

0544 502 42 40

FeyzullahBey

HAKKARİEL-PAİNŞ.ELK.

BOBİNAJ

SüleymanYAŞAR

CumhuriyetCd.

HalkbankKarşısı

No:26HAKKARİ

Tel.438.2115323-

211 94 23

211 61 43

Fax.438.2116143

YÜKSEKOVA

ÖZLEMISIT.SOĞ.

SAN.VETİC.LTD.

ŞTİ.

ŞemdinliYoluÜzeri

GençlikCd.No:245

YÜKSEKOVA

Tel.3512029-351

39 09

Fax.438.3518206

NihatGEÇİRGEN

505.7981895

GÜNEYDOĞU

ANADOLU

BÖLGESİ

SERVİSİNADI ADRESİ TELEFONVEFAKS

ŞANLIURFA ÇULLUTEKNİK

HasanÇULLU

YusufpaşaMh.

VatanSk.No:25/D

ŞANLIURFA

Tel.414.2151509

Fax.414.2151509

(542)5179149

DETAYTEKNİK

YenişehirMahallesi

230.SkKardelenApt

AltıNo:25/E

ŞANLIURFA

Page 52: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

50

GAZİANTEPBARANEND.MUT.

EKİP.LTD.ŞTİ

BaranÖLÇER

SarıgüllükMah.Fevzi

ÇakmakBulv.No:65/A

Şehrikamil

GAZİANTEP

Tel.342.3219650

Fax.342.3212057

532.3224230

532.7692812

SeydiDEMİR

ADIYAMAN FATİHSOĞUTMA

FatihUYKULU

T.ReisMh.Fevzi

ÇakmakCd.No:16/D

ADIYAMAN

Tel:04162166061

542.3047010

DİYARBAKIR

ARIZSOĞ.-ISITMA

TURZ.GIDASAN.

TİC.LTD.ŞTİ.

UrfaYolu1.Km

Men-KaAptAltı

Huzurevleri

DİYARBAKIR

0412.2381787

0 530 364 39 45

SaitSAYIN

AHMETMUMCU

PeyasMh.206

Sk.FaziletApt.Altı

No:12/EDİYARBAKIR

534 460 09 18

SİİRTEKOSOĞUT.SAN.

TİC

HamitAVCI

AydınlarCd.Özelİdare

İşHanıNo:13SİİRT

Tel.484.2246050

Fax.484.2238633

542 214 64 21

544 522 58 08

SerdarBey

TümİstekveŞikayetlerinizİçinAşağıdakiFaxveTelefonNumaralarından,

E-MailAdresindenBizeUlaşabilirsiniz.

Tel:224.2947474Fax:224.2433667

[email protected]

Page 53: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

51

Page 54: TEZGAH TİPİ - inoksan.com · CFC(kloroflorokarbon) gazını içermeyen R134a veya R404A freon gazı kullanılmaktadır. TAŞIMA VEYA YERİNDEN OYNATMA • Buzdolapları taşınırken

.INOKSAN KITCHEN INDUSTRY AND TRADE CO

FABRİKA FACTORY Organize Sanayi Bölgesi Ormanlar Cad. No:5 16159 Nilüfer / BURSA / TURKEY T: +9 0224 294 74 74 F: +9 0224 243 61 23 [email protected]

SATIŞ - PAZARLAMA SALES - MARKETING Yeni Yalova Yolu 6. Km No: 415 16250 Osmangazi / BURSA / TURKEY T: +9 0224 211 40 10 (6 Hat) F: +9 0224 211 40 17 [email protected]

İHRACAT EXPORT DEPARTMENT Organize Sanayi Bölgesi Ormanlar Cad. No:5 16159

Nilüfer / BURSA / TURKEY Tel: +90 224 294 74 74 (Pbx) Fax: +90 224 242 38 01 [email protected]

SATIŞ SONRASI HİZMETLER MÜDÜRLÜĞÜ AFTER SALES DEPARTMENT HEAD OFFICE Organize Sanayi Bölgesi Ormanlar Cadde No:5 16159 Nilüfer / BURSA / TURKEY T: +9 0224 243 94 00 F: +9 0224 243 36 67