AC500, AC500_eco, S500, S500_eco, CP400, CP600, CBP

Tng Quan V PLC, HMI, SCADA

Tng Quan V PLC

S Dng Cho Cc H Thng Nh, n L

S Dng Cho Cc H Thng Ln

Kh Nng M Rng

- Modul c th s dng giao thc CS31 kt ni- Trong giao thc CS31 c th kt ni ti 31 trm- Mi trm c th kt ni vi 120DI/120DO.- u vo s ti a: 328 ng- u ra s ti a: 246 ng- u vo analog ti a: 162 ng- u ra analog ti a: 161 ng- Ty chn gn thm ti a 10 modul- B m tc cao ln ti 50kHzAC500_eco3Kh Nng Kt Ni Vi Thit B Ngoi

Khi ng mmThit b ng ctCm bin nhit ng cng h lu lngNt nhn, n boBin tnng cUMC

Kh Nng Kt Ni Mng

in p cp: 24 VDC, 120/240 VACB nh EPROM v RAM: 644096 KB.Dung lng b nh bn trong: 283584 KBB nh ngoi thp nht (SD-Card): 512 MBS lng ng vo/ng ra ti a:320 ng vo s, 240 ng ra s.160 ng vo analog, 160 ng ra analog.Tch hp cng Ethernet hoc ARCNET (ty chn).C sn cc nhm c tnh khc nhau v tt c c th c lp trnh trong nm loi ngn ng lp tnh.Tch hp mn hnh LCD, Bn phm iu hnh, Mt khe cm th SD. H tr hu ht cc dng truyn thng sn c nh: Dng PLC AC500Profibus-DPProfinetDEVICENETCANopenEthernet TCP/IPEthercatWisa wirelessModbusRcomCS31

Dng PLC AC500_ecoin p: 24 VDC, 100-240 VAC.Dung lng b nh chng trnh: 128 KBS lng ng vo/ ng ra ti a:232 ng vo s, 174 ng ra s.112 ng vo analog, 112 ng ra analog.Tch hp ng h thi gian thc.Tch hp cng Ethernet hoc ARCNET (ty chn).Tch hp Webserver vi dng c cng EthernetHin th bo ngun, trng thi v li bng LED. C sn cc nhm c tnh khc nhau v tt c c th c lp trnh trong nm loi ngn ng lp tnh.H tr cc dng truyn thng ph binEthernetModbus RTUModbus TCP/IPRcomCS31ASCII ABB03 May 2013 | Slide 8AC500-ecoThi gian x l chng trnh 0.1 s/cu lnh ,v b nh chng trnh ln n 128 kB p ng y cho nhng ng dng ca bn. Cu hnh I/O (c th ngt cc ng vo , b m tc cao(ln n 50 kHz) v iu chnh rng xung cc ng ra) p ng d dng cho nhng nhu cu iu khin khc nhau.Ng vo c th c cu hnh analog hoc digital .Tnh linh hot cao vi vic tch hp sn I/O analog v digital trn board.

8Last Update:2008-10-30

Instructions:

ABB03 May 2013 | Slide 9C y cc giao thc truyn thng gip tit kim v thi gian v chi ph.Tch hp cng truyn thng Ethernet cho Modbus TCP, UDP Tch hp nhiu chc nng vo mt I/O,cho php bn thc hin cc gii php c th.D dng cu hnh mngAC500-eco

9Last Update:2008-10-30

Instructions:

ABB03 May 2013 | Slide 10Chng trnh phn mm da theo tiu chun IEC 61131-3C th m rng vi cc S500 I/O.Mang tnh linh hot cao ,p ng y nhng nhu cu khc nhau ca khch hng.D dng hc,c tnh tng hp cao,gip tit kim thi gian v mang li hiu qu.AC500_eco tng thch hon ton vi cc dng AC500 da vo phn mm CodeSys. Cc th vin th tng t nh trong AC500 c sn trong phn mm.

AC500-eco

10Last Update:2008-10-30

Instructions:

ABB03 May 2013 | Slide 11D dng vit chng trnhChng trnh khng qu i hi phi ti u ha v tc x l nhanh v c b nh ln.H tr nm ngn ng lp trnh c sn ty vo mi ng dng.S dng tin chLu gi d liu m khng cn pin.Download chng trnh n PLC qua th SD m khng cn n cng c lp trnhAC500-eco

11Last Update:2008-10-30

Instructions:

ABB03 May 2013 | Slide 12Tnh kinh t khi s dng S500-eco vi cc tip im I/O.Modules lin kt vi tt c cc module ca CPU AC500.Vic phn quyn cc I/O c th c tch hp vi bus CS31 hoc PROFINET.D dng lp tGn kt cc khi.DIN Rail mounting without toolsSpring terminals availableCc I/O c kch thc nh gn d dng cho vic kt ni.

S500-eco12Last Update:2008-10-30

Instructions:

ABB03 May 2013 | Slide 13AC500-eCoCc Thnh Phn C Bn Trong CPURun / Stop SwitchControls CPU operation

Status LED DisplayCPU operation & onboard I/O status

COM1Online access, Modbus RTUmaster/slave, CS31-Bus master, ASCII

Integrated Onboard I/OEthernet CPU with RJ45 Port

234512314513Last Update:2008-10-30

Instructions:Flexible choice of the communication interfaces.COM1: is a RS-485 serial interface and is connected to a 9-poles SUB-D connectorI/O-Bus: is I/O data bus for the S500 I/O, through this bus, I/O and diagnosis data are transferred between the AC500 CPU and the S500 I/O. ABB03 May 2013 | Slide 14

AC500-eCoCc Ph kin i Km14Last Update:2008-10-30

Instructions:Flexible choice of the communication interfaces.COM1: is a RS-485 serial interface and is connected to a 9-poles SUB-D connectorI/O-Bus: is I/O data bus for the S500 I/O, through this bus, I/O and diagnosis data are transferred between the AC500 CPU and the S500 I/O.

ABB03 May 2013 | Slide 15

TA566L44471101501L44470901501Front screw,front cableL44440901501Front spring,front cable

L44460901501Front screw, side cable

L44461101501

L44441101501Note: Only these types of ABB terminals can be used for the AC500-eCo I/O modules

Wall mounting accessoryAC500-eCoCc Ph kin i Km15Last Update:2008-10-07

Instructions:

ABB TypeABB Order CodeConnection typePolesMarkingQuantities in plastic bagL444709015011SSS444709R1100Front spring / Front cable91 to 96L444711015011SSS444711R1100Front spring / Front cable1110 to 206L444409015011SSS444409R1100Front screw / Front cable91 to 96L444411015011SSS444411R1100Front screw / Front cable1110 to 206L444609015011SSS444609R1100Front screw / Down side cable91 to 96L444611015011SSS444611R1100Front screw / Down side cable1110 to 206Order codes for I/O modules terminal blocksAC500-eCoCc Ph Kin i Km

AC500-eCoKch ThcLast Update:2008-10-07

Instructions:

ABB03 May 2013 | Slide 18Details/TypePM554-TPM554-RPM554-R-ACPM554-T-ETHPower supply24VDC24VDC100-240VAC24VDCUser program memory128 kB128 kB128 kB128 kBUser data memory14KB incl. 2KB (RETAIN+%R) 14KB incl. 2KB (RETAIN+%R) 14KB incl. 2KB (RETAIN+%R) 14KB incl. 2KB (RETAIN+%R) SD cardOptionalOptionalOptionalOptionalData bufferingFlashFlashFlashFlashReal-Time ClockOptionalOptionalOptionalOptionalProcessing timeper instructionBinary0,1s0,1s0,1s0,1sWord0,3s0,3s0,3s0,3sFloating-point 6s6s6s6sI/O's onboardBinary inputs8888Trans. outputs 6--6Relay outputs-66-Max. centralizedinputs/outputsBinary inputs232232232232Binary outputs 174174174174Analog inputs 112112112112Analog outputs112112112112Communication onboardCS31 busyesyesyesyesModbusyesyesyesyesEthernet ---yesAC500-eCoThng S K Thut Ca CPU18Last Update:2008-10-07

Instructions:

ABB03 May 2013 | Slide 19Details/TypePM564-TPM564-RPM564-R-ACPM564-T-ETHPM564-R-ETHPM564-R-ETH-ACPower supply24VDC24VDC100-240VAC24VDC24VDC100-240VACUser program memory128 kB128 kB128 kB128 kB128 kB128 kBUser data memory14KB incl. 2KB (RETAIN+%R) 14KB incl. 2KB (RETAIN+%R) 14KB incl. 2KB (RETAIN+%R) 14KB incl. 2KB (RETAIN+%R) 14KB incl. 2KB (RETAIN+%R) 14KB incl. 2KB (RETAIN+%R) SD cardOptionalOptionalOptionalOptionalOptionalOptionalData bufferingFlashFlashFlashFlashFlashFlashReal-Time ClockOptionalOptionalOptionalOptionalOptionalOptionalProcessing timeper instructionBinary0,1s0,1s0,1s0,1s0,1s0,1sWord0,3s0,3s0,3s0,3s0,3s0,3sFloating-point 6s6s6s6s6s6sI/O's onboardBinary inputs666666Trans. outputs 6--6--Relay outputs-66-66Configurable inputs 222222Analog outputs111111Max. centralizedinputs/outputsBinary inputs232232232232232232Binary outputs 174174174174174174Analog inputs 114114114114114114Analog outputs113113113113113113Communication onboardCS31 busyesyesyesyesyesyesModbusyesyesyesyesyesyesEthernet ---yesyesyesAC500-eCoThng S K Thut Ca CPU19Last Update:2008-10-07

Instructions:

ABB03 May 2013 | Slide 20Details / TypeDI561DI562DI571DO561DO571DO572DX561DX571DC561Number of channel per moduleDI 24 V DC816----88-DI 100 - 240 V AC--8------DO---88888-DC--------16Relay (R) ----yes--yes-Transistor (T)---yes--yes--Triac (Tri)-----yes---Interfast--------yesAC500-eCoThng S K Thut Ca Modul S20Last Update:2008-10-07

Instructions:

ABB03 May 2013 | Slide 21Details/TypeAI561AO561AX561AI562AI563Number of channel per module AI / AO4/00/24/22/04/0 Resolution (bit)1212121616 Isolation process signals to logic---yesyesInputs, single configurable 80 mV----yes 2,5 Vyes-yes-- 0 - 10 Vyes-yes-- 5V, 0 - 5Vyes-yes-- 0/4 - 20 mAyes-yes-- Pt100, Pt1000---yes- Ni1000---yes- Ni100---yes- Thermo J, K, N, S, T----yes Thermo R, E----yesOutputs, single configurable 10 V-yesyes-- 0 /4 - 20 mA-yesyes--AC500-eCoThng S K Thut Ca Modul Analog21Last Update:2008-10-07

Instructions:

ABB03 May 2013 | Slide 22Tng Quan:Thit k nh gn, gn trn DIN-rail hoc gn tngCao v dt hn so vi dng modul S500 Mi 1 CPU kt ni c ti a 10 modulC 3 loi gic ni cho mnh lc chnLoi nhn (l xo t)2 loi vt vnB CcI/O-BusTn cc ng vo/ran LED vng bo trng thi cho cc tn hiu u vo/ra nh s v tr r rngTn tn hiuJack kt ni I/O 9 v 11 cc (Screw type or spring)AC500-eCoModul Dng S500-eco

12435622Last Update:2008-10-30

Instructions:

ABB03 May 2013 | Slide 23Module ng vo DI561 - module m rng loi nh 8 ng vo sin p 24V DCSink / Source inputs Cch ly v inGia ng vo v mc logic ca module.

AC500-eCoModul Dng S500-eco23Last Update:2008-10-30

Instructions:For all I/O assignment: blue->inputs; green->outputs; red->configurable input/output.

ABB03 May 2013 | Slide 24Ng vo DI56216 ng vo digital. in p 24V DCMt chn chung.Sink / Source inputsCch ly v in gia cc ng vo v mc logic ca module.

AC500-eCoModul Dng S500-eco24Last Update:2008-10-30

Instructions:

ABB03 May 2013 | Slide 25DI571 module cho ng vo AC8 ng vo digitalin p 120 / 240V ACCch ly v inCho mi knhGia ng vo v mc logic ca module.

AC500-eCoModul Dng S500-eco25Last Update:2008-10-30

Instructions:

ABB03 May 2013 | Slide 26Ng ra module DO561 output8 ng ra digital loi trnistor24V DC, 0.5A (cho mi knh)Cch ly v in gia cc ng vo v mc logic ca module.

AC500-eCoModul Dng S500-eco26Last Update:2008-10-30

Instructions:

ABB03 May 2013 | Slide 27Module ng ra DO571 - module c dng in ng ra cao AC/DC 8 ng ra digital loi relay.Kh nng mang ti : 24V DC, 2A hoc 230V AC, 2APilot duty (Load in acc. to UL 508): 120VAC 2A / 240VAC 1.5A2 chn chung.Khng c bo v ngn mch.Cch ly v inGia cc cng tc relay v mc logic ca module.

AC500-eCoModul Dng S500-eco27Last Update:2008-10-30

Instructions:

ABB03 May 2013 | Slide 28Module ng ra DO572 Module c ng ra l triac8 ng ra triac.in p:110 / 240V AC, 0.3ACch li v inGia cc knh.Gia cc ng ra v mc logic ca module.

AC500-eCoModul Dng S500-eco28Last Update:2008-10-30

Instructions:

ABB03 May 2013 | Slide 29DX561 module vo/ra 8 ng vo digital24V DCMt chn chungSink / Source inputs8 ng ra digital loi transistor .24V DC, 0.5A (mi knh)Khng c bo v ngn mch.Cch ly v inGia cc nhm.Gia ng vo,ng ra vi mc logic ca module.

AC500-eCoModul Dng S500-eco29Last Update:2008-10-30

Instructions:

ABB03 May 2013 | Slide 30Module vo/ra DX571 - module c dng in cao.8 ng vo digital in p:24V DCMt chn chungSink / Source inputs.8 ng ra digital loi relay.2A2 chn chung.Khng c bo v ngn mch.Cch ly v inGia cc chn..Gia ng vo,ng ra vi mc logic ca module.

AC500-eCoModul Dng S500-eco30Last Update:2008-10-30

Instructions:

ABB03 May 2013 | Slide 31Module DC561 16 ng vo/ra c cu hnh:24V DC, 0.1A (mi knh)Khng c bo v ngn mchCng Interfast kt ni n cc thit b ca ABB .Cch ly v in:Gia cc ng vo/ra vi mc logic ca module.

AC500-eCoModul Dng S500-eco31Last Update:2008-10-30

Instructions:

ABB03 May 2013 | Slide 32Cp kt ni cho DC561 .

AC500-eCoModul Dng S500-eco32Last Update:2008-10-30

Instructions:

Cp Interfast cho DC561

Cc khi Interfast DC561BRI 1621 N with 16 relaysBOM 16 with terminal connection

AC500-eCoModul Dng S500-eco ABB03 May 2013 | Slide 34AI5614 ng vo analog .-2.5V +2.5V-5V +5V0 5V0 10V0 20mA4 20mA phn gii: 11 bit plus signKhng c cch ly

AC500-eCoModul Dng S500-eco34Last Update:2008-10-30

Instructions:

ABB03 May 2013 | Slide 35AO561 2 ng ra analog-10V +10V0 20mA4 20mA phn gii: 11 bit plus signKhng c cch ly

AC500-eCoModul Dng S500-eco35Last Update:2008-10-30

Instructions:

ABB03 May 2013 | Slide 36AX5614 ng vo analog -2.5V +2.5V-5V +5V0 5V0 10V0 20mA4 20mA2 ng ra analog -10V +10V0 20mA4 20mA phn gii: 11 bits plus signKhng c cch ly

AC500-eCoModul Dng S500-eco36Last Update:2008-10-30

Instructions:

ABB03 May 2013 | Slide 37AI562 2 ng vo RTD Pt100 hoc Pt10002-dy / 3-dy-50C +400CNi100 or Ni10002-dy / 3-dy-50C +150Cin tr0 1500 300 phn gii: 15 bitsCch li v in

AC500-eCoModul Dng S500-eco37Last Update:2008-10-30

Instructions:

ABB03 May 2013 | Slide 38AI563 module ng vo analog .Cu hnh cho 4 ng vo:in p: -80mV +80mVCc dy o:E-270 +1000CJ-210 +1200CK-270 +1372CR -50 +1768CS -50 +1768CT-270 +400CN-270 +1300C phn gii: 15 bits cch ly v in Gia cc ng vo v mc logic ca module

AC500-eCoModul Dng S500-eco38Last Update:2008-10-30

Instructions:

ABB03 May 2013 | Slide 39AC500-eCoS Kt Hp Linh Hot Ca CPU V I/O

CPU AC500 vi modul S500 v S500-eCoTi a 10 modules S500 v S500-eCo Kt ni c ti a 4 modul truyn thng

CPU AC500-eCo vi modul S500 v S500-eCo I/OTi a 10 modules S500 hoc S500-eCo

39Mglichkeit, alle Komponenten miteinander zu mischenCS31 on AC500-eCo COM1

Modbus on AC500-eCo COM2 (option)Modbus SlaveModbus master

AC500-eCoV D 1CS31 MasterS500 I/OCS31-Interface + I/OS500 I/OCS31-Interface + I/O

Last Update:2008-11-21

Instructions:The COM1 interface of the AC500 can be configured as a CS31 field bus master. The CS31-Bus can be used for the decentralized expansion.CS31 for continuity and migration: CS31 is a proprietary master/slave field bus. It is characterized by simple handling, easy configuration and inexpensive installation.

Modbus on AC500-eCo COM2 (option)HMIModbus slave

Modbus on AC500-eCo COM1Modbus Master

Modbus master

Modbus SlaveAC500-eCoV D 2Last Update:2008-11-21

Instructions:The COM1 interface of the AC500 can be configured as a CS31 field bus master. The CS31-Bus can be used for the decentralized expansion.CS31 for continuity and migration: CS31 is a proprietary master/slave field bus. It is characterized by simple handling, easy configuration and inexpensive installation.

CS31 on AC500-eCo COM1Modbus on AC500-eCo COM2 (option)HMIModbus slaveModbus master

S500 I/OCS31-interface + I/OCS31 masterS500 I/OCS31-interface + I/O

AC500-eCoV D 3Last Update:2008-11-21

Instructions:The COM1 interface of the AC500 can be configured as a CS31 field bus master. The CS31-Bus can be used for the decentralized expansion.CS31 for continuity and migration: CS31 is a proprietary master/slave field bus. It is characterized by simple handling, easy configuration and inexpensive installation.

Modbus on AC500-eCo COM2 (option)HMIModbus slave

Programming, UDP or MODBUS TCP on EthernetModbus Master

S500 I/O CS31-interface + I/OCS31 on AC500-eCo COM1PC with PS501CS31 master

AC500-eCoV D 4Last Update:2008-11-21

Instructions:The COM1 interface of the AC500 can be configured as a CS31 field bus master. The CS31-Bus can be used for the decentralized expansion.CS31 for continuity and migration: CS31 is a proprietary master/slave field bus. It is characterized by simple handling, easy configuration and inexpensive installation.

PS501 Control Builder Plus Cung Cp:

Chc nng lp trnh mnh mKh nng m phng, hin th tin tinChun on v g li d dngCu hnh mng v kt ni mng d dngCp nht tham s ha t xa vi s lng ln tt c cc chi tit my

Bao Gm Cc Tnh Nng:

Lp trnh mnh m vi IEC 61131-3 v Cy l mt cng c dnh cho lp trnh v cu hnh PLC AC500, AC500-eCo v cc bin tn h th chuyn bit c cung cp bi ABB.H tr 5 ngn ng lp trnh t tiu chun quc t ca IEC 61131-3.Thm vo chc nng PLC c th c lp trnh di dng ngn ng ANSI-C v c tch hp s dng mt trnh bin dch bn ngoi.Phn Mm Lp Trnh

Phn Mm Lp TrnhM Phng, Hin Th Tin Tin

Control builder plus h tr nhiu hnh thc hin th tintin c tch hp snHin th c tch hp khi s dng trc tuynHin th c lp c s dng trn PC vi m bo vHin th mng c cu hnh bi control builder plusTch hp phn mm cho dng mn hnh CP600Tch hp OPC Server vi CodeSys

Chun on v g li d dng

y l phng thc qun l cho nhng gii php sn xut n ginHin th cng c a cu hnh thun li v tm nhn tng quan v cc tc v ty chnh.Chun on v g li thong minh d dng hn khi c s dng trc tuyn.Qun l cnh bo li gip nng cao qu trnh chy th v bo dng.Cu Hnh Mng V Kt Ni Mng D Dng

Cu hnh Fieldbus n gin v kt ni chui:Profibus-DP, CAN, CANOpen, Modbus, Serial v ABB IO-bus CS31, DeviceNet vi b cu hnh Sycon.netCu hnh mng chun Ethernet thi gian thc n gin:Profinet, EtherCATB giao thc mng Internet bao gm:HTTP (mng my ch ti AC500 CPU)SNTP (ng b ha thi gian ca cc CPU)SMTP (tin nhn s v cc phn mm km theo)FTP (truyn d liu)DHCP ( cu hnh IP t ng)TCP/IP (kim sot truyn ng tiu chun v giao thc mng Internet)UDP/IP (mng truyn thng tc cao)

Phn Mm Lp Trnh

Phn Mm Lp Trnh ABB03 May 2013 | Slide 49Diagnosis, Service

Automation Programming

Add-Ons

Visualization

EngineeringSoftwarePhn Mm Lp Trnh49 ABB03 May 2013 | Slide 50AutomationPS501 V1.3.2Chng trnh cho tt c cc CPU AC500-eCo ngoi tr ETHERNET CPU PS501 V2.1.0Chng trnh cho tt c cc CPU AC500 & AC500-eCo PS501 V2.2.0Chng trnh cho tt c cc CPU AC500 & AC500-eCoLp trnh, thit t thng s cho bin tn PM554-tPM554-RPM554-R-ACPM564-TPM564-RPM564-R-ACPM554-T-ETHPM564-T-ETHPM564-R-ETHPM564-R-ETH-ACPS501 V1.3.2YesYesYesYesYesYesNoNoNoNoPS501 V2.0YesYesYesYesYesYesYesYesYesYesPhn Mm Lp Trnh50Ci t Phn Mm Lp Trnh PLC

Cho a vo i mn hnh autorun s hin th nh trnSau kch chut vo phn mm lp trnh PLC_AC500Mn hnh k tip xut hin

kch chut vo Ci Phn Mm Control Builder PlusSau c lm theo hng dn tip tc.Phn mm s t ng tm kim v ci t phn mm CodeSys cho bn

Ci t Phn Mm Lp Trnh PLC

Ci t Cc Phn Mm Cng CMt s tool cng c

Sau khi ci xong trn desktop xut hin biu tng

M Chng Trnh Lm Vic bt u m chng trnh lm vic ln bn click i chut vo biu tng trnHoc c th vo: Start all Program ABB Control builder Plus

Mn hnh tng t nh bn s xut hin

To 1 D n Mi bt u to 1 d n mi click chut vo biu tng trnHoc c th vo: file new

Chn loi CPUChn ni lu d nt tn cho d nNhn OK tip tc

Chn Cu HnhChn cu hnh I/O onboardCc th ngun dng lu chnAdd thm modulCa s thc hin cu hnh, t bin symbol

Chn Cu HnhCu hnh cho cng COMLu chn phng thc truynCu hnh cho cng ethernet

M Trnh Son Tho CodeSysSau khi thit lp xong cu hnh click chut vo save lu li cu hnhClick i chut vo y m trnh son tho58

M Trnh Son Tho CodeSysSau khi kch vo AC500 chng trnh s hi bn c cp nht cu hnh khngChn l YesTrong ca POUs xut hin PLC_PRG mc nh vit trn ngn ng ST, nhng bn c th thay i sang cc ngn ng khc nh FBD.LD,IL,CFC,SFC

Trnh Son Tho CodeSys

chn ngn ng lp trnh khc bn click chut phi vo PLC_PRG ri chon deleteSau click chut vo POUs chut phi Add ObjectTrnh Son Tho CodeSys

t tn POULa chn ngn ng lp trnhIL = Danh sch Ch dnLD = S hnh ThangFBD = S khi Chc nngSFC = Biu Chc nng Tun tST = Vn bn C cu trcCFC = Biu chc nng lin tc (logic)

Chn kiu cho POU:Program: chng trnhFunction block: khi chc nngFunction: chc nng

ABB Group May 3, 2013 | Slide 62Task: Program PRGFunction FUNFUNFUNFUNFBFunction block FBPRGFBfirst instructionlast instructionCu Trc Ca Chng Trnh

Trnh Son Tho CodeSysThanh cng cVng lp trnhVng khai bo bin ni b

Trnh Son Tho CodeSysBc 1: kch vo vng lp trnhBc 2: kch vo contact -- > t tn, gn binBc 3: kch vo function block-- > t tn, gn binBc 4: kch vo coil-- > t tn, gn bin

1234on chng trnh to xung nhy