    Seismic response assessment andSeismic response assessment and

    upgrading of a complex of seven RCupgrading of a complex of seven RCbuildings using FRPsbuildings using FRPs

    T.B. Panagiotakos, A.J. Kosmopoulos & B. KoliasCivil Engineer, PhD. Civil Engineer, PhD. Civil Engineer

    International fib Symposium, May 2008, AmsterdamTailor Made Concrete Structures New Solutions for Our Society

    Development & Engineering Consultants S.A.Development & Engineering Consultants S.A.16 Kifissias Ave. 15125 Maroussi

    Tel. +30 210 6854801-6 ,fax +30 210 6854800

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    2/25

    Existing (older) buildings in seismic regions:

    Typically inadequate (if any) engineered earthquake resistance.

    Until recently:

    Retrofitting of existing buildings was addressed in an empiric

    manner by modern Codes

    Part 3 Eurocode 8 (EN 1998-3:2005):

    Is the 1stNorm to establish rules & expression for the assessment

    of the seismic performance & retrofitting of existing buildings(including the use of FRPs)

    Deformation-based approach (for ductile failure modes)

    Tools for the engineers upgrade existing structures to meet (ifpossible) the requirements of modern codes for the design of

    new buildings.

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    3/25

    Performance Levels & targets for the retrofitting

    Knowledge Levels of available data & confidence factors

    Primary & Secondary Elements (for lateral loads) Effect of infill walls

    Linear analysis (under restrictions) w/ local ductility

    Non-Linear analysis

    Force and deformation-based performance checks

    Computational tools expressions for the assessment of

    structural capacity

    EN 199EN 19988--33 Introduces:Introduces:

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    4/25

    EN 1998EN 1998--3 performance levels:3 performance levels:

    DesiredDesired performanceperformance duringduring thethe respectiverespective earthquakeearthquake..

    InIn termsterms ofof:: Structural damageStructural damage

    Protection of the occupants lifeProtection of the occupants life Serviceability after the earthquakeServiceability after the earthquake

    DifferentDifferent criteriacriteria forfor structuralstructural // nonnon--structuralstructural elementselements

    ServesServes socialsocial && financialfinancial criteriacriteria

    ThreeThree performanceperformance levelslevels // designdesign earthquakesearthquakes:: Damage LimitationDamage Limitation Significant DamageSignificant Damage

    Near CollapseNear Collapse

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    5/25

    Key modeling aspects:Key modeling aspects:

    PrismaticPrismatic 33DD beambeam elements,elements, w/w/ inelasticityinelasticity lumpedlumped atat thethe twotwo endsends..

    ElasticElastic stiffnessstiffness takentaken equalequal secantsecant stiffnessstiffness atat yielding,yielding, ((EIEI))effeff,, basedbased onon thethevaluevalue ofof thethe shearshear spanspan atat thethe yieldingyielding end(s)end(s) ofof thethe membermember;; beamsbeams andandcolumnscolumns areare assumedassumed toto yieldyield atat bothboth endsends inin oppositeopposite symmetricsymmetric bendingbending(shear(shear spanspan equalsequals halfhalf thethe clearclear lengthlength ofof thethe elementelement;;

    TheThe averageaverage valuevalue ofof ((EIEI))effeff atat thethe twotwo endend sectionssections inin positivepositive oror negativenegativebendingbending isis usedused;;

    BeamsBeams supportedsupported onon anotheranother beambeam atat oneone endend yieldingyielding isis assumedassumed toto occuroccuronlyonly atat thethe otherother endend;; thethe shearshear spanspan isis takentaken equalequal toto thethe fullfull clearclear spanspan ofofthethe beambeam..

    EffectiveEffective flangeflange widthwidth ofof TT-- oror LL--beamsbeams onon eithereither sideside ofof thethe beambeam webweb isistakentaken equalequal toto 5050%% ofof thethe minimumminimum ofof beambeam shearshear span,span, distancedistance toto thetheadjacentadjacent parallelparallel beambeam;;

    slabslab barsbars parallelparallel toto thethe axisaxis of of aa beambeam areare consideredconsidered fullyfully effectiveeffectivelongitudinallongitudinal reinforcementreinforcement ofof thethe beambeam endend sectionsection;;

    ForFor wallswalls onlyonly thethe secantsecant--toto--yieldingyielding stiffnessstiffness ofof thethe basebase sectionsection inin aa storystory isisusedused;; shearshear spanspan isis takentaken asas equalequal toto 5050%% ofof thethe heightheight fromfrom thatthat sectionsection totothethe toptop ofof thethe wallwall..

    ModelingModeling assumptionsassumptions havehave beenbeen validatedvalidated byby fullfull--scalescale PsDPsD teststests..

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    6/25

    BasedBased onon ANSRANSR--I,I, developeddeveloped atat thethe UniversityUniversity ofof Patras,Patras, GreeceGreece andandDENCODENCO DevelopmentDevelopment && EngineeringEngineering ConsultantsConsultants inin Athens,Athens, GreeceGreece

    LinearLinear elasticelastic analysisanalysis (static(static oror modal)modal) inin 33DD;;

    NonlinearNonlinear staticstatic (pushover)(pushover) andand nonlinearnonlinear dynamicdynamic analysisanalysis inin 33DD;;

    InIn--planeplane flexibilityflexibility ofof floorfloor diaphragmsdiaphragms;;

    EstimationEstimation ofof thethe effectiveeffective (secant)(secant) stiffnessstiffness ofof membersmembers atat yieldingyieldingfromfrom reinforcementreinforcement andand materialmaterial propertiesproperties;;

    VerificationVerification ofof ductileductile modesmodes of of membermember behaviourbehaviour inin termsterms of ofdeformationsdeformations (chord(chord--rotationsrotations atat membermember ends)ends) atat thethe threethree LimitLimit StatesStatesforeseenforeseen inin ENEN19981998--33;;

    VerificationVerification ofof membersmembers inin shearshear;;

    DesignDesign ofof thethe retrofittingretrofitting includingincluding estimationestimation ofof thethe effectiveeffective (secant)(secant);; stiffnessstiffness toto yielding,yielding, flexuralflexural andand shearshear resistanceresistance andand cycliccyclic deformationdeformation

    capacitycapacity ofof membersmembers retrofittedretrofitted usingusing RCRC oror FRPFRP jacketsjackets..

    Computational tool for the analysisComputational tool for the analysis ANSRuop softwareANSRuop software

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

    DEVELOPMENT & ENGINEERINGCONSULTANTS S.A.

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    7/25

    Assessment of the seismic performance and retrofitting of a Complex of7 RC buildings built in the 1970s to house the Data Processing Centre ofthe Bank of Greece (Data: Knowledge Level 2 according to EN 1998-3)

    Typical floor plan view

    3D computer model for the analysis

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    8/25

    Non-linear time-history analyses (least conservative; most reliable) Semi-artificial ground motions compatible w/ the Codes elastic 5%-damped spectrum

    -0.3

    -0.2

    -0.1

    0

    0.1

    0.2

    0.3

    0 1 2 3 4 5 6 7 8 9 1 0 1 1 12 1 3 14 1 5

    -0.2

    -0.1

    0

    0.1

    0.2

    0.3

    0 1 2 3 4 5 6 7 8 9 1 0 1 1 12 1 3 14 1 5

    -0.2

    -0.1

    0

    0.1

    0.2

    0.3

    0 1 2 3 4 5 6 7 8 9 1 0 1 1 12 1 3 14 1 5

    -0.3

    -0.2

    -0.1

    0

    0.1

    0.2

    0.3

    0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

    -0.3

    -0.2

    -0.1

    0

    0.1

    0.2

    0.3

    0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

    -0.3

    -0.2

    -0.1

    0

    0.1

    0.2

    0.3

    0 1 2 3 4 5 6 7 8 9 1 0 1 1 12 1 3 14 1 5

    -0.3

    -0.2

    -0.1

    0

    0.1

    0.2

    0.3

    0 1 2 3 4 5 6 7 8 9 1 0 1 1 12 1 3 14 1 5

    -0.3

    -0.2

    -0.1

    0

    0.1

    0.2

    0.3

    0 1 2 3 4 5 6 7 8 9 1 0 11 1 2 1 3 14 1 5

    -0.3

    -0.2

    -0.1

    0

    0.1

    0.2

    0.3

    0 1 2 3 4 5 6 7 8 9 1 0 11 1 2 1 3 14 1 5

    -0.2

    -0.1

    0

    0.1

    0.2

    0.3

    0 1 2 3 4 5 6 7 8 9 1 0 11 1 2 1 3 14 1 5

    -0.3

    -0.2

    -0.1

    0

    0.1

    0.2

    0.3

    0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

    -0.3

    -0.2

    -0.1

    0

    0.1

    0.2

    0.3

    0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

    -0.2

    -0.1

    0

    0.1

    0.2

    0.3

    0 1 2 3 4 5 6 7 8 9 1 0 11 1 2 1 3 14 1 5

    -0.3

    -0.2

    -0.1

    0

    0.1

    0.2

    0.3

    0 1 2 3 4 5 6 7 8 9 1 0 11 1 2 1 3 14 1 5

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    9/25

    Comparison of the response spectra of the semi-artificial groundmotions to the elastic spectrum of the Greek Seismic Code

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

    Non-linear time-history analyses (continued) Semi-artificial ground motions compatible w/ the Codes elastic 5%-damped spectrum

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    10/25

    DemandDemand--toto--CapacityCapacity ratio,ratio, :: comparisoncomparison ofof demand,demand, D,D, totocapacity,capacity, C,C, inin termsterms ofof deformationdeformation (ductile(ductile failurefailure modes)modes)oror forceforce (brittle(brittle failurefailure modes)modes) forfor eacheach structuralstructural elementelement::

    Demand, D, from analysisDemand, D, from analysis

    Capacity, C from EN 1998Capacity, C from EN 1998--3 expressions3 expressions

    Safety factors forSafety factors for:: Material propertiesMaterial properties

    Knowledge Level of available dataKnowledge Level of available data

    Reliability of structural modelsReliability of structural models

    Analysis using probable (mean) values of material propertiesAnalysis using probable (mean) values of material properties

    C

    D!P

    Assessment of the seismic performanceAssessment of the seismic performance

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    11/25

    Significant Damage (SD) performance level

    D/C ratios of beams end-chord rotations (flexure)

    D/C ratios of columns end-chord rotations (flexure)

    Near Collapse (NC) performance level

    D/C ratios of beams end-chord rotations (flexure)

    D/C ratios of columns end-chord rotations (flexure)

    D/C ratios of beams in terms of shear force

    D/C ratios of columns in terms of shear force

    Results from nonResults from non--linear timelinear time--history analyseshistory analyses::

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    12/25

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

    Results of non-linear time-history analyses D/C ratios of beams end-chord rotations (Significant Damage Performance Level)

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    13/25

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

    Results of non-linear time-history analyses D/C ratios of beams end-chord rotations (Near Collapse Performance Level)

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    14/25

    Results of non-linear time-history analyses D/C ratios of columns end-chord rotations (Significant Damage Performance Level)

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    15/25

    Results of non-linear time-history analyses D/C ratios of columns end-chord rotations (Near Collapse Performance Level)

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    16/25

    Results of non-linear time-history analyses D/C ratios of beams in terms of shear force

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    17/25

    Results of non-linear time-history analyses D/C ratios of columns in terms of shear force

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    18/25

    Building top displacements and interstory drift values werewithin acceptable limits;

    Numerous columns (mainly at the upper floors) and a significantnumber of beams exhibit shear deficiencies;

    A few columns exhibit deficiencies in flexure and ductility.

    Evaluation of the analyses resultsEvaluation of the analyses results

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

    Retrofitting strategyRetrofitting strategy

    Retrofitting w/ RC jackets or overlays presents several problems

    and disadvantages (time, cost, aesthetic) The seismic upgrading was implemented by means of externally

    bonded Fiber Reinforced Polymer (FRP) sheets.

    Target of the retrofitting: Seismic performance that complieswith Near Collapse Performance Level according to EN 1998-3.

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    19/25

    Retrofitting with FRP sheetsRetrofitting with FRP sheets

    Retrofitting for the increase of shear capacity:

    For each element which is foreseen to be subjected to a shear force beyond its shear capacity,this excess shear is calculated (Vmax,anal VR)

    Choice of retrofitting material : GFRP sheets

    Direct dimensioning of the retrofitting (number of FRP layers) for the excess shear force

    according to EN 1998-3 .4.4.2, taking into account the possibility of failure of the RC-FRPinterface before maximum strain of the FRP is reached (debonding)

    Confinement and increase of deformation capacity

    (retrofitting against ductile failure modes):

    Choice of retrofitting material : GFRP sheets

    Dimensioning: for each element that is foreseen to fail in flexure, a number of FRP layers isassumed for the increase (through confinement, A.4.4.3) of the ultimate end-chord rotation, u(A.3.2.2.) so as to prevent failure

    Calculation of the new value ofu and check for the adequacy of the selected number of FRP

    layers

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    20/25

    Retrofitting of columns for increase of flexural deformation capacity Layers of GFRP sheets

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    21/25

    Retrofitting of beams for increase of shear capacity Layers of GFRP sheets

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    22/25

    Retrofitting of columns for increase of shear capacity Layers of GFRP sheets

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    23/25

    Schematic view of the retrofitting (Office buildings)

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    24/25

    A complex of 7 RC buildings (built in the 1970s) was upgradedseismically to withstand the design earthquake (according to theGreek Seismic code)

    Evaluation of the buildings and design of the retrofitting wereaccording to EN1998-3

    Externally bonded Fiber Reinforced Polymers (FRPs) were used:cost-effective way of improving the seismic performance withoutmodifying dynamic response

    ConclusionsConclusions

    InternationalInternational fibfib Symposium Amsterdam 2008Symposium Amsterdam 2008 Tailor Made Concrete Structures /Tailor Made Concrete Structures / New Solutions for our SocietyNew Solutions for our Society

  • 8/8/2019 TPANAGIOTAKOS-Amsterdam 2008

    25/25

    Seismic response assessment and upgrading of a complex ofSeismic response assessment and upgrading of a complex ofseven RC buildings using FRPsseven RC buildings using FRPs

    T.B. Panagiotakos, A.J. Kosmopoulos & B. Kolias

    Civil Engineer, PhD. Civil Engineer, PhD. Civil Engineer

    International fib Symposium, May 2008, AmsterdamTailor Made Concrete Structures New Solutions for Our Society

    Development & Engineering Consultants S.A.Development & Engineering Consultants S.A.

    16 Kifissias Ave. 15125 MaroussiTel. +30 210 6854801-6 ,fax +30 210 6854800

    Thank you!Thank you!