tro tr ba irreport 01 10 gb - trotec.com - trotec · trotec® gmbh & co. kg • grebbener...

40
TROTEC ® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52 / 962 - 200 www.trotec.de • E-Mail: [email protected] TRO-TR-BA- IRSOFTWARE-01-10-GB IC-Report DuoVision G Operating manual – IR-Software B - 1

Upload: others

Post on 04-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 HeinsbergTel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52 / 962 - 200www.trotec.de • E-Mail: [email protected]

O-TR-B

A-IR

SOFT

WARE-01-10

-GB

IC-Report DuoVision

G Operating manual – IR-Software B - 1

Page 2: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

B - 1 Operating manual – IR Software G

CONTENTS

1.0 Installation........................A-011.1 SystemRequirement................A-011.2 InstallIC-ReportDuoVision............A-021.3 UninstallIC-ReportDuoVision.........A-03

2.0 Gettingstarted......................A-042.1 LaunchApplication .................A-042.2 TerminateApplication................A-04

3.0 Introduction.........................A-043.1 Interfaces .......................A-043.2 Functions ........................A-04

4.0 ThermalAnalysis....................A-154.1 OpenIRFile........................A-154.2 OpenImage........................A-154.3 CloseImages......................A-154.4 Drawing..........................A-154.5 Temperature........................A-184.6 Chart.............................A-19

5.0 ImageProcess ....................A-225.1 OpenIRFile .......................A-225.2 IsothermalArea ....................A-225.3 ImageAdjustment...................A-235.4 AreaAdjusting......................A-235.5 IRImageSwitch ....................A-245.6 Fusion ............................A-245.7 Snapshot..........................A-25

6.0 Report........................... A-256.1 GeneratingReport....................A-256.2 ReportBuild .......................A-256.3 SaveReport .......................A-266.4 OpenIRTFile.......................A-266.5 SaveIRTFile.......................A-266.6 Print..............................A-26

7.0 FileProcessing ...................A-267.1 Preview ..........................A-267.2 Merge............................A-277.3 Edit.............................. A-27

8.0 Monitoring............................. A-278.1. USB-Monitoring......................A-278.2. NET-Monitoring......................A-288.3. MonitoringScreen....................A-28

9.0 IRrecording...................... A-29

10.0Recordplay...................... A-29

11.0Imagemerging.................... A-30

12.0Systemsettings................... A-3112.1SaveFile..........................A-3112.2Snapshot..........................A-3112.3Record............................A-3112.4Re-record.........................A-3212.5DataExport........................A-3212.6OpenFile..........................A-3312.7System............................A-3312.8TemperatureCalibration...............A-33

13.0Versioncomparsion................ A-35Thispublicationreplacesallpreviousannouncements.Nopartofthispublicationmaybereproduced,processedusingelectronicsystems,replicatedordistributedinanyform,withoutourwrittenauthorisation.Subjecttotechnicalchanges.Allrightsreserved.Namesofgoodsareusedwithoutguaranteeoffreeusagekee-pingtothemanufacturer‘ssyntax.Thenamesofgoodsusedareregisteredandshouldbeconsideredassuch.Wereservetherighttomodifydesignintheinte-restofongoingproductimprovement,suchasshapeandcolourmodifications.Thescopeofdeliverymayvaryfromthatintheproductdescription.Allduecarehasbeentakenincompilingthisdocument.Weacceptnoliabilityforerrorsoromissions.©TROTEC®

1.0 INSTALLATION

1.1 SystemRequirement

Windows-XP(only32Bit-Version):

SP2above,Memory512MBabove,CPU700Hzabove,Framework2.0above,MonitorResolution1024x768above

Windows-Vista(only32Bit-Version):

SP1 above, Memory 1GB above, CPU 1GHz above,Framework2.0above,MonitorResolution1024x768above

Page 3: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

G Operating manual – IR Software B - 2

m The IC-Report DuoVision does not support USB real time monitoring on Vista currently

1.2 InstallIC-ReportDuoVision

-Findtheinstallationprogramanddoubleclick theprogramfileicon.

-ClicktheNextbuttontocontinuetheinstallationor

Cancelbuttontoterminatetheinstallation.

-OntheLicenseAgreementscreen,clickYesbutton tocontinuetheinstallationorNobuttontoterminatetheinstallation.

-Chooseaninstallationharddriveandfilepathby clickingtheBrowsebuttonorusethedefaultdriver andfilepath(Pleaseensurethereisenoughspace ontheselecteddrive).

-ThenclicktheNextbutton.

-ConfirmtheprogramfolderandclickNext.

-ThiswilltakeyoutotheStartCopyingFilesdialogue box.ClicktheNextbutton.

Page 4: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

B - 3 Operating manual – IR Software G

-Click the Finish button. If your computer does nothaveMicrosoftFramework2.0(oralaterversion)ins-talled,theprogramwillpromptyouwithamessagetoinstallFramework2.0.ClicktheOkbuttonandfollowthe installation instruction on the screens to installFramework2.0software.

If you see “Setup cannot continue because this version of the .Net Framework is in-compatible with a previously installed one” message during the Framework installation, please go to Control Panel, double click Add or Remove Programs in XP or Programs and Features in Vista to remove previous versi-on of the Framework and uninstall the IC-Report DuoVisionXXX software (See section 1.2, where XXX is version name, such as Std, Pro, USB, NET). Follow the above steps to re-install the application.

-ClicktheYesbuttontorestartyourcomputerafter theinstallationiscompleted.

1.3 UninstallIC-ReportDuoVision

-ClickStartatthebottomleftoftheWindows’s desktop.UndertheIC-ReportDuoVisionXXXof AllProgramsclickUninstallIC-ReportDuoVisi onXXXandfollowingtheinstructionstoremove theIC-ReportDuoVisionXXXsoftware.

m

Page 5: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

G Operating manual – IR Software B - 4

2.0 GETTING STARTED

2.1 LaunchApplication

Therearetwosimplewaysyoucanlaunchthepro-gram.ClickStartatthebottomleftoftheWindows’sdesktopandundertheIC-ReportDuoVisionXXXoftheAllProgramsselectIC-ReportDuoVisionXXX.YoucanalsosimplydoubleclicktheIC-ReportDuoVisionXXXicononyourWindowsDesktop.

Note:For theprofessionalversion,usermustplugadongleassociatedwiththesoftwareontothecompu-ter.Otherwise,theprogramwillbeterminated.

2.2 TerminateApplication

Usercan terminate theapplicationbyselectingExitfromtheFilemenuorclickingthetoprightbutton.

3.0 INTRODUCTION

3.1 Interfaces

TheFigureshowsthemaininterfaceoftheapplication,whichhasmenus,atoolbar,anIRanalysisarea,andin-formationareas.Operationalfunctionscanbeselectedusingthemenus,toolbar,orbyrightclickingthemouseontheimageitself.TheIRanalysisareaisacontainerfordisplayinganalysisofthermaland/orCCDimages.Theinformationareasdisplayanalysisdata,status,andresults.

3.2 Functions

- Filter Setatemperaturerangeasafileopenfilter,whichonlyopensthermalimagesinwhichthe maximumtemperaturevaluefallsintoaspecified temperaturerange.

Examples: -Openthermalimagefile(s)inwhichthemaximum temperatureislessthanorequalto60degreeCel sius.

-Openthermalimagefile(s)inwhichthemaximum temperatureisgreatthanorequalto60degree Celsius.

Page 6: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

B - 5 Operating manual – IR Software G

-Openthermalimagefile(s)inwhichthemaximumtemperaturesisbetween40and60degreeCelsius.

-Openthermalimagefile(s)inwhichtheminimum temperatureisgreatthanorequalto40degreeCelsius.

-Openthermalimagefile(s)inwhichthemaximum temperatureislessthanorequalto40degreeCel- sius.

- Open IR File YoucanopenoneormultiplethermalimagesinSAT, JPGwiththermaldata,andBMPwiththermaldatafor- matfiles.Youcanalsoopenassociateddigitalimage inCCDformatforfusionwork. Action:menuFile=>OpenIRFileorclicktheOpen IRFileshortcut.

- Open Image OpenoneormultipledigitalimageinJPGorBMP format.Thedigitalimagecanbeusedforanalysis reportingandimagefusionwithathermalimage. Action:menuFile=>OpenImageorclicktheOpen Imageshortcut.

Page 7: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

G Operating manual – IR Software B - 6

- Save Report InReportMode,savethecurrentanalysisresults intoaWordformatfile(.doc). Action:menuFile=>SaveReport=>selectfile nameandpath=>ClickSavebutton.

- Batch Report ForPro,USB,orNETversion,usercanselecta reporttemplateandmultiplethermalimagestogenerateWordformatreports(.doc)ornewreport templates(.irt).BatchReportusesselectedthermal imagestoreplacethethermalimage(s)inthereport templateandrecalculateanalysisresults.

Action:menuFile=>BatchReport

-SelectSingleFileorSeparateFileforthereport generating.SingleFilewillsaveallreportsintoa

singleWordfileandSeparateFilewillsavethe reportsintoseparatefiles.

-Choosereporttemplatemethods:1)searchatem- plate(.irtfile)fromfilebrowseofleftside,drag anddropthethumbnailofthetemplateintothe TemplateNameboxontherightside,2)directly typethepathandtemplatenameintothe TemplateNameboxontherightside,3)click BrowsebuttonontherightofTemplateNamebox, selectatemplate.

-Choosethermalimagemethods:searchthermal images(.sator.jpgwiththermaldatafile)from filebrowseofleftside,1)draganddropthesel- ectedthumbnailsofthermalimagefilesintothe SelectedImageboxontherightside,2)clickAdd button.Theprogramusestheselectedthermal imagesinone-by-oneordertoreplacethermal imagesinthetemplate.Whenthelastthermalimage isreplaced,anewpageorreportwillbe generated.Ifresidueislessthanthenumberof imagesinthetemplate,therestthermalimages willkeepunchanged.

- Choosepathandfilenamethatthereportwill besaved;

- Selectfiletypeofthegeneratedreport;

- ClickGeneratebutton

- Open IRW File -Openananalysisworkingfile(.irw).TheIRW includesallanalysisobjectsandresultssaved fromananalysissession,whichallowyouto continuelastanalysissession.

Page 8: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

B - 7 Operating manual – IR Software G

IRW File is available for the PRO, USB, or NET version.

Action:menuFile=>OpenIRWFile=>select aworkingtemplatefileinExplore=>ClickOpen button.

- Save IRW File -Inanalysismode,youcansaveallanalysis contentsexceptFusionandImageMerging windows/containersintoaworkingfile(.irt)and openitlatertocontinueanalysis.

IRW File is available for the PRO, USB, or NET version

Action:menuFile=>SaveIRWFile=>specify workingtemplatefilename=>ClickSavebutton

- Open IRT File -Openareporttemplatefile(.irt)intoreportmode forediting.TheIRTisaformattedreporttemplate filethatcanbeusedtogeneratebatchreports(see 3.2.5BatchReport). Action:menuFile=>OpenIRTFile=>selecta reporttemplatefileinExplore=>ClickOpenbutton.

- 9. Save IRT File -Inreportmode,youcansavethecurrentformatted contentsexceptFusionandImageMergingwindows/ containersasareportingtemplateintoafile(.irt). Thetemplateisusedtogeneratebatchreport,which usesselectedthermalimageandanalysisdatainthe templateformattoformanalysisreports(see3.2.5 BatchReport). Action:menuFile=>SaveIRTFile=>specify reporttemplatefilename=>ClickSavebutton.

m

m

Page 9: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

G Operating manual – IR Software B - 8

- 10. Save IR As -Yousaveanopenedthermalimageormultiple thermalimagesintofile(s)inaspecifiedformat. Action:menuFile=>SaveIRAs=>specifyimage(s), type,temperaturescale,temperaturedata,path =>ClickOK.

ChoosingtheCurrentImagemeanstosavethe currentselectedthermalimageintoafi le. ChoosingtheAllImagesmeanssaveallthermal imagesinAnalysisorReportwindowintofiles. Youcanspecifyafiletype(JPG,BMP,orSAT).For JPGandBMPtypes,youcanspecifywhetheror notincludesthetemperaturescaleofthethermal image.ForJPGtype,youcanspecifywhether ornotincludestemperaturedataofthethermal image.IfanimageissavedinJPGformatwith temperaturedata,youcanopenitasathermal imageandperformanalysisasanimageinthe SATformat.

No Temperature Data option for Standard ver-sion.

SpecifyfilepathandnamethroughtheBrowse andclickOK.ClickCanceltoaborttheoperation. UncheckShowThisDialoguemeansthisdialogue windowwillnotbeshownwhenyouperformSaveIR Asoperation.Youcancheckoruncheckthisoptionbox inSystem=>Settings=>SaveFileaswell- Print Preview Underreportmode,previewformatofthecurrent reportbeforeprinting. Action:menuFile=>PrintPrevieworclickprint previewshortcut.- Print Underreportmode,sendthecurrentreportto printerdirectly. Action:menuFile=>Printorclickprintshortcut.- 13. Exit Terminatetheapplication. Action:menuFi le=>Exit orcl icktopr ight button.- Restore Tools InAnalysisMode,youcanrestoredeleteddrawings/ toolsinabackwardorder.Thatmeanslastdeleted andfirstrestored. Action:menuAction=>RestoreToolsorclickthe RestoreToolsshortcut.- Undo InReportMode,youcanrestoredeleteddrawings andanalysiscomponentssuchaschart,table, andtextinabackwardorder. Action:menuAction=>UndoorclicktheUndo shortcut.

m

Page 10: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

B - 9 Operating manual – IR Software G

- Redo InReportMode,youcanrestorelastUndowork. Forexample,afteryouundoadeletedchart,the redowilldeletethischartagain. Action:menuAction=>RedoorclicktheRedo shortcut.- Zoom out Enlargethecurrentthermalimage.Youcanuse mousetodragedgeofathermalimagetochangeits size. Action:menuAction=>ZoomoutorclicktheZoom outshortcut.- Zoom in Reducesizeofthecurrentthermalimage.Youcan usemousetodragedgeofathermalimagetochange itssize. Action:menuAction=>ZoominorclicktheZoom inshortcut.- Original SizeRestorethecurrentthermalimagetooriginalsize. Action:menuAction=>OriginalSizeorclickthe OriginalSizeshortcut.- Data Export Exporttemperaturevaluesofaselectedthermal imageinamatrixofrowsandcolumnsintoTxt, CSV,orMicrosoftExcelformatfile.Youcanspecify atemperaturerange,whichexportdatawillbe blankifatemperaturevalueisoutofthetempera- turerange.

A file in CSV format can be opened by a text edit tool and Microsoft Excel. Ex-porting data into CSV file is much faster than into Excel file. Therefore, using CSV file for data export is recommended.

Action:menuAction=>DataExport.

- Distribution Aftergenerateadistributionchart,youcanright clickonthedistributioncharttoexportthedistribu- tiondataintoafileinCSVformat.

- Trend ForthePRO,USB,orNETversion,youcanexporttrend dataofarecordorrealtimemonitor. Fortherecord,rightclickontherecordwindowand selectTrend.YoucanrightclickonTrendchartand selectStartExportDataandclickPlaytobegindata export.AndrightclickontheTrendchartandselect StopExportDatatoendofdataexport.Whenstopdata export,youcanspecifyaf i lenametostore exporteddata.TheexportdataissavedintheCSV formatthatcanbeopenedbytextedittoolorMicrosoft Excel.DataExportgeneratestwofilesthatoneis maximumtemperaturetrendandanotherisminimum temperaturetrend..

m

Page 11: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

G Operating manual – IR Software B - 10

Fortherealtimemonitor(USBandNETversions only),rightclickonthemonitorwindowandselect Trend.YoucanrightclickonTrendchartandselect StartExportDatatobegindataexport.Andright clickontheTrendchartandselectStopExportData toendofdataexport.Whenstopdataexport,you canspecifyafilenametostoreexporteddata.The exportdataissavedintheCSVformatthatcanbe openedbytextedittoolorMicrosoftExcel.Data Exportgeneratestwofilesthatoneismaximum temperaturetrendandanotherisminimumtempe- raturetrend.

- Partial Trend ForthePRO,USB,orNETversion,youcanexport wholeorpartialtrenddataofarecord.Rightclick ontherecordwindowandselectPartialTrend. Youcanexportthewholetrenddatabyrightclick andselectDataExportonthelefttrendchart.You canspecifyexportdata,minimumand/ormaximum. TheexportdataissavedintoaCSVformatfilethat canbeopenedbytextedittoolorMicrosoftExcel.

Youcanexportthepartialtrenddatabyrightclick andselectDataExportontherighttrendchart. Youcanspecifyexportdata,minimumand/or maximum.TheexportdataissavedintoaCSV formatfilethatcanbeopenedbytextedittoolor MicrosoftExcel.

- Snapshot Takeasnapshotofthecurrentthermalimageand saveitasanewimagefileinSAT,BMP,orJPGformat. YoucanopentheJPGsnapshotfileusingOpenIR FileasathermalimageorOpenImageasadigital image. Action:menuAction=>Snapshotorclickthesnapshotshortcut =>specifytypeandfile name=>Save

Page 12: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

B - 11 Operating manual – IR Software G

- File Processing ForthePRO,USB,orNETversion,youcaneditther- malrecordfile,suchasconcatenatefilesordelete selectedimages. Action:menuAction=>FileProcessingorclickthe FileProcessingshortcut .- Play Audio Listentovoicerecordinathermalimagefile.If thethermalimagedoesnothavevoicerecord,the shortcutisdisabled. Action:menuAction=>PlayAudioorclickthePlay Audio shortcut .- Fusion BlendathermalimagewithaBMP,CCD,orJPG image. Action:menuAction=>FusionorclicktheFusion shortcut =>selectthermalandCCDimage =>Ok.- Image Subtraction ForthePRO,USB,orNETversion,calculatetempera- turevaluedifferenceatthesamepointoftwother- malimagesandgenerateatemperaturedifference image.Imagesubtractioncanbeusedtoanalyze temperaturechangesofthesameviewofthermal imagesthatistakenatdifferenttime. Action:menuAction=>ImageSubtraction=> selectthermalimages=>OkorApply.

Forexample,therightimageshowstemperature differenceoftwoleftthermalimage.Theimage generatedbysubtractionisathermalimageas well.Therefore,youcandoanalysisonit.

- 26. Image Merging ForthePRO,USB,orNETversion,Adjoinspecified thermalimageand/orareaintoonethermalimage. Action:menuAction=>ImageMergingorclick imagemergingshortcut .- Close current IR image ClosethecurrentIRimagewindow. Action:menuAction=>ClosecurrentIRimage orclicktopright buttonoftheIRimagewindow.- Close All Analysis Windows Closeallopenedanalysiswindows. Action:menuAction=>CloseAllAnalysisWindows orclickCloseAllAnalysisWindowsshortcut- Tools Plotapoint,line,vernier,circle,rectangle,polygon, orpoly-lineonthecurrentthermalimageformore detailedanalysis. Action:menuTools=>selectadrawtypeorclick oneofdrawingshortcuts- Max Temperature Showthemaximumtemperatureandcoordinateof thecurrentthermalimage Action:clicktheMaxTemperatureshortcut- Min Temperature Showtheminimumtemperatureandcoordinateof thecurrentthermalimage. Action:clicktheMinTemperatureshortcut

Page 13: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

G Operating manual – IR Software B - 12

- Cursor Showthetemperatureandcoordinateatthecursor pointofthecurrentthermalimage. Action:clicktheCursorshortcut- Isothermal Area Paintanimage’spixelsthatdenotetemperatures fallingwithinaspecifiedtemperaturerangeusinga selectedcolor. Action:menuTools=>IsothermalAreaorclick IsothermalArea shortcut orrightclickmouse andselectathermalimage=>IsothermalArea- Delete tool Deleteaselecteddrawing Action:menuTools=>Deletetoolorclickthe DeleteDrawingsshortcut ,thenclickaselec- teddrawing.- Clear all tools Clearalldrawingsonthecurrentthermalimage window. Action:menuTools=>Clearalltoolsorrightclick mouseonathermalimage=>Clearalltools.- Temperature Range FortheUSBorNETversion,youcanselecta calibratedtemperaturerangeforcalculation.When thetemperaturerangechange,systemwillalso sendacommandthroughRS232lineorEthernetto changeIRcamera’stemperaturemeasurement range(PleasecheckIRcamera’susermanualto seeifyourIRcamerahasswitchingtemperature rangefunction). Action:menuMonitororrightclickmouseonathermal image=>TemperatureRange=>selectarange

- USB Monitor FortheUSBversion,throughUSBtoconnectanIR camera,performrealtimemonitorandanalysisof thermalimage.ThefunctionisavailableforUSB versiononly.SeeIRcameramanualaboutUSB connection. Menü Monitor => USB Monitor or left click USB- MonitorIcon- NET Monitor FortheNETversion,throughEthernettoconnect oneormultipleNetIRcameras,performrealtime monitorandanalysisofthermalimage. Note:thefunctionisavailablefornetworkversion only.SeeIRcameramanualaboutEthernetconnection. Menü Monitor => NET-Monitor or left click the NET-MonitorIcon-IRCameraModel SelectanIRCameraModelifyoupurchasesoftware versionthatsupportsmultipletypesofcameras.-DualVisionPlayer FortheNETversion,theplayercanplaydualvision (CCDandIR)recordfile. GehenSiewiefolgtvor:MenüMonitor=>IRKamera Modell oder klicken Sie auf das Symbol => öffnen SieeineDuoVision-Aufnahme.

Opendualvisionrecordfile First Previous Play Next Last Replay- Language

Page 14: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

B - 13 Operating manual – IR Software G

Allowusertoselectanavailablelanguageforthe applicationinterface. Action:menuSystem=>Language- Temperature Scale SelecttheCelsiusorFahrenheittemperaturescale. Action:menuSystem=>TemperatureScale- Temperature Settings Setparametersoftemperaturecalculationfora thermalimageoraselectedarea. Action:menuSystemorrightclickmouseona thermalimage=>TemperatureSettingsorclick TemperatureSettingsshortcut

- Palette Selectapalettetomaptemperaturevaluesofa thermalimage.Theapplicationprovidesseven palettesandeachonecanbereversed. Action:menuSystemorrightclickmouseona thermalimage=>PaletteorclickPaletteshortcut- Image Adjusting Specifyatemperaturevaluerangeofthecurrent imageasacolormappingspan.Ifthetemperature valuesoftheimagefalloutsidethisrange,theywill bemappedtoeitherupperorlowerendofthe palette.Theimageadjustmentcanhighlightordetail certainpartsofthethermalimage.

When you see, for example, >> 19.2, or << 3, on the palette scale, it means that the tem-perature values of the image that are greater than >> 19.2, or less than << 3, are mapped with upper end or lower end colors.

Action:menuSystemorrightclickonathermal image=>ImageAdjustingorclickImageAdjusting shortcut- Initial Settings Setsysteminitialparameters. Action:menuSystem=>InitialSettings- Emissivity Allowusertomanageemissiondatausedfor temperaturecalculation. Action:menuSystem=>Emissivity- Generating Report Enterfreestylereportingmode.Youcanbuildor editatemplateforbatchreport. Action:clickReportshortcut

- Analysis Mode EnterAnalysisModefromReportMode. Action:clickAnalysisModeshortcut

When you click Analysis Mode shortcut, the Report Mode window is minimized. You can go back to the Report Mode by click Maximize button on top right of the Report Mode win-dow.

- Area Adjusting For the PRO, USB, or NET version, use temperature valuerangewithinaselectedareaascolormapping-

m m

Page 15: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

G Operating manual – IR Software B - 14

span.Ifthetemperaturevaluesoftheimagefallout- sidethisrange,theywillbemappedtoeitherupper orlowerendcolorofthepalette.Theimageadjust- mentcanhighlightordetailcertainpartsofthe thermalimage. . Action:rightclickmouseonathermalimage =>AreaAdjusting- Three Dimension Showthecurrentthermalimageinathreedimensionview. Action:rightclickmouseonathermalimage =>ThreeDimension- Copy to Clipboard Copythecurrentthermalimageintosystem’sclip- boardsoyoucanpastetheimageintootherapplica- tionsuchasWorddocument. Action:rightclickmouseonathermalimage =>CopytoClipboard- IR Image Switch Youcanreplacethecurrentthermalimagewithano- therthermalimage. Action:rightclickmouseonathermalimage=> IRImageSwitch.- Temperature Label Enableordisabletemperaturevalueand/orcoordi- natedisplayatthecursorpoint,maximumtempera- turepoint,minimumtemperaturepoint,and/ortem- peraturedifference. Action:rightclickmouseonathermalimage =>TemperatureLabel- Histogram Displayastatisticalgraphofafrequencydistribution oftemperaturetakenfromaselectedcircle,rectangle, orpolygonareaofathermalimage. Action:movemousecursorontoanarea=> rightclickmouseonathermalimage=> Histogram

-Distribution Displaydistributionoftemperaturesofaselected lineorploy-lineofathermalimage. Action:movemousecursorontoalineorpoly-line =>rightclickmouseonathermalimage=> Distribution- Partial Trend ForthePRO,USB,orNETversion,youcangenerate wholetrendswithitspartialtrendsofmaximumand minimumtemperaturefromathermalrecordor monitor. Action:rightclickmouseonathermalimage=> PartialTrend- Trend ForthePRO,USB,orNETversion,youcangenerate trendsofmaximumandminimumtemperaturefrom asequentialthermalimages,record,ormonitor. Youalsocangeneratetrendsofmaxandmintem- peratureofawholeimages,points,lines,orareas fromathermalrecordormonitor. Action:rightclickmouseonathermalimage =>Trend- Multiple Trends ForthePRO,USB,orNETversion,youcangenerate trendsofmax,min,and/oraveragetemperature usingsequentialthermalimages.Youalsocange- neratetrendsofmax,min,and/oraveragetempe- ratureofawholeimages,points,lines,orareasfrom multiplethermalrecordormonitorwindowsintoone trendchart. Action:menuAction=>MultipleTrendsorclick shortcut

Page 16: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

B - 15 Operating manual – IR Software G

- Multiple Distributions ForthePRO,USB,orNETversion,youcanproduce temperaturedistributionsoflinesorpoly-linesfrom multiplethermalimageswindowsintoonedistribu- tionchart. Action:menuAction=>MultipleDistributionsor clickshortcut-Apply ClickingApplybuttonmakessettingseffectiveand staysinthesamewindow.-OK ClickingOkbuttonmakessettingseffectiveand exitsthecurrentwindow.-Cancel ClickingCancelbuttoncancelsasettingoroperati- on.

4.0 THERMAL ANALYSIS

4.1 OpenIRFile

Byclicking theOpen IRFileshortcut orOpen IRFilefromthemenu,youcanexploreandopenoneormulti-plethermalimagefilesatonce(SeeFig.4.1.1).Theap-plicationsupportsSAT(.sat),JPGwiththermaldata,andBMPwiththermaldataformatfiles.ItcanalsoopenCCDformat(.ccd)imagefiles.

Fig.4.1.2showsopenedthermalimagesintheanaly-sisarea.Theinformationareaontherightsideoftheanalysisareawilllisttemperatureinformationofeachthermal image and associated drawings displayingfile or drawing name, maximum temperature, mini-mum temperature, average temperature, emissivity,ambienttemperature,relativehumidity,effectivedis-tance,andtemperaturecorrection.

4.2 OpenImage

By clicking the Open Image shortcut or OpenImage from themenu,youcanexploreandopenoneormultipleimagefilesatonce.TheapplicationsupportsJPGandBMPimagefiles.

4.3 CloseImages

Youcanclick onthetoprightofadisplaywindowtocloseanimageorclicktheshortcut to close allopenedimagewindowsintheanalysisarea.

4.4 Drawing

Youcanusedrawing toolplot linesorareas toanaly-ze temperature changes at certain parts of a thermalimage.

- Point

Click the short- cuttobeginplottingpoint(s)on a thermal image.Click the shortcut againorright clickmouseonthethermalimagetoendthedrawing function(SeeFig.4.4.1).

Page 17: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

G Operating manual – IR Software B - 16

- Line

Click the shortcut tobegindrawingline(s)on

athermalimage.Toendthedrawingfunction,clickthe shortcut againorrightclickmouse.

- Vernier

Click the shortcut to begin drawing a vernier on aselectedlineinathermalimage.Clicktheshort-

cutagainorrightclickmousetoendthedrawing function.You can change the vernier locationby placinglocationbyplacingyourcursoratadesired locationonthelineandclicking,whichisusefulwhen youwanttoviewtemperatureatdifferentpointona lineinthedistributionchart.

- Circle

Click the shortcut toplotcircle(s)onathermal image.Toturnoffthisfeature,clicktheshortcutagainor rightclickbutton.

- Rectangle Click the shortcut toplotrectangle(s)onathermal image.Click theshortcut againorrightclick mousetoendthedrawingfunction.

- Polygon Clicktheshortcut tobeginplottingpolygon(s)on athermalimage,singleclickingtocompletetheedges ofapolygonandfinallydoubleclickingtocompletethe lastedgeandclosethepolygon.Youcanclickthe

shortcutagainorrightclickmousetoendthe drawingfunction.

- Poly-line Clicktheshortcut toplotpoly-line(s)ona thermalimage,singleclickingtocompletealine ofapoly-lineanddoubleclickingtocompletethe last l ineof thepoly- l ine.Youcancl ickthe shortcut againorrightclickmousetoendthe drawingfunction.

Page 18: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

B - 17 Operating manual – IR Software G

- Changes Placecursoronadrawing(e.g.point, l ine, circle,rectangle,polygon,orpoly-line)toresizeit orchangeitslocationwhennodrawingshortcutis selectedorclicked.Thefollowingshapesofmouse cursorindicatewhatoperationyoucanperformon aselecteddrawing.

MovePoint–pressandholdleftbuttonofmousetomovetheselectedpoint.Releasethebuttonwhenthepointismovedtodesiredlocation.

MoveLine–pressandholdleftbuttonofmouseto move the selected line. Release the buttonwhenthelineismovedtodesiredlocation.

Rotate/ResizeLine–pressandholdleftbuttonof mouse to rotate or resize the selected line.Releasethebuttonwhenthechangeisdone.

MoveRectangle–pressandholdleftbuttonofmousetomovetheselectedrectangle.Releasethebuttonwhentherectangleismovedtodesi-redlocation.

ResizeRectangle–pressandholdleftbuttonofmousetochangetheselectedrectanglesizeinthearrowpointeddirection.Releasethebuttonwhentheoperationisdone.

Move Circle – press and hold left button ofmousetomovetheselectedcircle.Releasethebuttonwhenthecircle ismovedtodesired lo-cation.

Resize Circle – press and hold left button ofmouse to change the selected circle size inthearrowpointeddirection.Releasethebuttonwhentheoperationisdone.

Move Polygon – press and hold left button ofmouse to move the selected polygon. Releasethebuttonwhenthepolygonismovedtodesiredlocation.

MoveVertex of Polygon – press and hold leftbuttonofmousetomovetheselectedvertexofthepolygon.Releasethebuttonwhenthevertexismovedtodesiredlocation.

AddVertextoPolygon–pressandholdleftbut-tonatapointof theselectededgewhereyouwanttoaddanewvertex,movecursortomovethenewvertextoadesiredlocation.Releasethebuttonwhenthevertexissettled.

Move Poly-line – press and hold left button ofmouse to move the selected poly-line. Releasethebuttonwhenthepoly-lineismovedtodesiredlocation.

MoveVertex of Poly-line– press andhold leftbuttonofmousetomovetheselectedvertexofthepoly-line.Releasethebuttonwhenthever-texismovedtodesiredlocation.

AddVertextoPoly-line–pressandholdleftbut-ton at a point of the selected edge where youwanttoaddanewvertex,movecursortomovethenewvertextoadesiredlocation.Releasethebuttonwhenthevertexissettled.

Page 19: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

G Operating manual – IR Software B - 18

- Entfernen Click the shortcut andusethecursortoselect adrawing.Whenthecursorischangedtoadeleting shape ( Point, L ine, Circle, Rectangle, Polygon, Poly-line),leftclickyourmouse to remove the drawing. Click the shortcut a secondtimetoendthedeletingoperation. OR Rightclickmouseonathermalimageandclick ClearAllDrawingsfromthepopupmenu,which allowsyoutoremovealldrawingsontheimageat once.

- 5. Restore Tools C l ick the shortcut to restoredeleted drawingsonthecurrentthermalimagewindow. Thedrawingswillberestoredinreversechronology (“lastdeletedfirstrestored”).

4.5. Temperature- Range Calibratedtemperaturerangeprovidedbythema- nufacturerisoneoftheparametersfortemperature calculationofinfrareddata.Aninfraredcameracan havemultiplecalibratedtemperaturerangesifitis equippedmultiplelensesand/orfilters.Forexample, ifaninfraredcameraisequippedwithonelens andhastwoembeddedfilters,itwillhavethreeca libratedtemperaturerangeswherethefirstrangeis forthelensonly,thesecondisforthelenswithone filtercovered,andthethirdisforthelenswithtwo filterscovered.Ifaninfraredcamerahasnofilter, thesecondandthirdrangeforalenswillbeassig- nedwiththefirstone(SeeexampleofFig.4.5.1).Du- ringrealtimemonitoring,youcanmeasuredifferent temperaturerangesbyselectingacalibratedtem- peraturerange. Rightclickmouseonathermalimage,click TemperatureRangefromthepopupmenu,andchoo- seacalibratedtemperaturerangebyclickingthe radiobuttoninthetemperaturerangelist(SeeFig. 4.5.1).Pleasereferenceinfraredcamerauserma-

nualabouthowtoselectacalibratedtemperature range.

Temperature Range feature is only available for the USB or NET version.

- Label First,rightclickmouseonathermalimageandclick TemperatureLabelfromthepopupmenu.Youcan setlabelswithtemperaturevalueandcoordinates forthemaximumtemperaturepoint,minimumtem peraturepoint,andcursorpointonathermalimage bycheckingorun-checkingoptionboxes(SeeFig. 4.5.2).Youcanalsoassignacommentasapartofa label. TempDiffshowsthedifferencebetweenmaximum andminimumtemperaturesofalineoranarea. TempDiffofEndsshowsthetemperaturedifference betweentwoendpointsofaline. YoualsocandoubleclickonthePointLabel,TempDiff,orTempDiffofEndstochangelabel’scolor.

m

Page 20: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

B - 19 Operating manual – IR Software G

For the STD version, you can only label tem-perature values for the whole thermal image. For the PRO, USB, or NET version, you can label temperature for the whole thermal image and analysis tools (e.g. point, line, etc.).

- Settings Besidesthecalibratedtemperaturerange,theemis- sivityofmaterial,ambienttemperature,relativehumi- dity,effectivedistance,andtemperaturecorrectionare parametersofthetemperaturecalculation.Youcan setparametersbyrightclickingonathermalimage andchoosingTemperatureSettingsfromthepopup menu.Youcansetparametersofthewholeimageand anyspecifieddrawing(e.g.point,line,circle,rectangle, poly-line,andpolygon).

Youcanenteremissionvalueorclick toselecta system provided value. Each material in the list has a range of emissivity and default emission value.When you select a row andclick Ok or Apply,thedefaultemissionvaluewillbeused. Whenyoudoubleclickanemissionvalue inaco- lumnofarow,thatvaluewillbeused.

4.6Chart

- Histogram Thechartcanshowtemperaturestatisticsofaspe- cifiedthermalarea.Forgeneratinghistogram,move cursorontoaselectedcircle,rectangle,orpolygon; rightclickmouseandclickHistogramfromthepo- pup menu. You can right click mouse on a chart windowtosetnumberoftemperaturesegmentsfor statistics and color scheme of the histogram (See Fig).You can move the area to view the statistics results.

For the PRO, USB, or NET version, you can edit Emissivity table and add emission data.

- Distribution Thechartshowstemperaturedistributionofaselec- tedlineorpoly-line.Forgeneratingdistributionchart, trghtclickmouseonaselectedlineorpoly-lineand choose Distribution Chart from the popup menu. showstemperaturedistributionchartsoflineL1with avernier,lineL2,andpoly-lineCur1.Ifavernieris onalinelikeL1,youcanmovetheverniertosee temperaturevalueandcoordinateofvernierposition.

Youalsocanviewthedistributionchangesbymoving alineorpoly-line.

m

m

Page 21: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

G Operating manual – IR Software B - 20

- Multiple Distributions ForthePRO,USB,orNETversion,youcangenerate multipledistributionsofdifferentlinesfromthe sameordifferentimagesintoasingledistribution chartforanalysisorcomparison.

Steps:MenuAction=>MultipleDistributionsor click shortcut .

RightclickontheMultipleStaticImageAnalysiswin- dow,chooseDistributionConnect.

Selectlinesfordistributioncharts,clickOK;

RightclickontheMultipleDistributionschartand selectDeletetoclosethechart.

- 6. Partial Trend

ForthePRO,USB,orNETversion,youcangetpartial trendsofminimumandmaximumtemperaturesof thecurrentthermalrecord.

Rightclickonathermalrecord=>selectPartial Trend.

InPartialTrendchartwindow,theleftchartshowsthe trendoftherecord,therightshowsapartialtrendbet- weentwoverticallinesintheleftchart.Youcanmove twoverticallinesintheleftcharttoselectasegment toviewpartialtrend.Thisfeatureisveryusefulfor trendanalysisofalengthyrecord.Youcanviewthe wholetrendanddetailsinpartialtrend.

Youcanmovetheverticallineintherightchartto viewsequentialnumber,maximumtemperature, andminimumtemperatureofarecordedimage.

- Trend

ForthePROversion,youcangettrendsofminimum andmaximumtemperaturesofathermalrecord.

Page 22: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

B - 21 Operating manual – IR Software G

FortheUSBorNETversion,youcangettrendsof minimumandmaximumtemperaturesofareal timemonitor.

Rightclickonathermalrecordormonitorwindow =>selectTrend=>ifitisrecord,clickPlay.

- Multiple Trends ForthePRO,USB,orNETversion,youcangenerate multiplemaximum,minimum,and/oraveragetempe- raturetrendsofdifferenttools(e.g.point,line,circle, rectangle,poly-line,andpolygon)andthermalimages intoasingletrendchartforanalysisorcomparison. ForthePROversion,onlycansequentialthermalima- gesandthermalrecordsbeusedtoproducemultiple trendanalysis.FortheUSBorNETversion,youcando multipletrendanalysisfromrealtimemonitors.

MenuAction=>MultipleTrendorclickshortcut =>rightclickontheTrendwindow=>clickTrend Connect.

Ifthecurrentwindowisastaticthermalimage,you cangeneratetrendsofminimum,average,and/or

maximumtemperatureofthewholeimageortools fromsequentialthermalimages.Forstaticimage trend,theremustbeatleasttwothermalimagesope- ned.Youcanarrangeorderofthestaticthermalima- gesandchooseatoolofonethermalimageasabase tocreatetrends.

Forexample,youopenedthermalimages(IR2–IR13) andsetinanorderofIR5,IR2,IR3,IR4,IR6,IR13,IR7, IR8,IR9,IR10,IR11,andIR12.UselineL1ofIR13asa trendbasetogeneratemaximumandaveragetem- peraturetrends.Inthiscase,thetrendsareproduced bythefollowingsteps: 1. GetL1positionoftheIR13image; 2. Calculatemaximumandaveragetemperatureva- luesforeachIRimagesintheorderbasedonthe L1position; 3. LinkmaximumtemperaturevalueoftheL1inor- derofIR5,IR2,IR3,IR4,IR6,IR13,IR7,IR8,IR9, IR10,IR11,andIR12; 4. LinkminimumtemperaturevalueoftheL1inor- derofIR5,IR2,IR3,IR4,IR6,IR13,IR7,IR8,IR9, IR10,IR11,andIR12.

Page 23: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

G Operating manual – IR Software B - 22

Thetrendofstaticimageallowsyoutoanalyzetem peraturechangesofthesameobjectfromimages thathavethesameviewbutweretakenatdifferent times. Iftheselectedwindowisathermalrecordormonitor, trendsofminimum,average,andmaximumtempera- turesofthewholeimageorselectedtoolsarepro- ducedbychoosingthermalimagesand/ortoolswith temperaturetype.

5.0 IMAGE PROCESS

5.1Palette

YoucanchangecolorschemeofwholethermalimagebyrightclickingonathermalimageordrawingareaandclickingPalettefromthepopupmenu.(SeeFig.)shows,beforeandafter,thechangesofcolorschemesfromaGreypalette.

Thesystemprovidessevenpalettesandtheirreversedsettings.YoucanchecktheReverseboxtogetacom-plementarypalettescheme.For thePRO,USB,orNET

version,youcansetapaletteforindividualtoolarea(e.g.circle,rectangle,andpolygon).

5.2IsothermalArea

Youcanmarkaspecifiedtemperaturerangebysettingisotherm.Two isothermal areas canbe set per image(SeeFig.).

Thefollowingisothermalsettingsareavailable.

• PaintObject–Selectthewholeimageoradrawing areatoperformisothermalanalysis(Note:forprofessi- onalversiononly).• Preview–Selectanisothermalrange1or2.• Color–Selectacolorfortheisothermalareaby doubleclickingcolorbox.• Top–Movetheisothermalrange1or2uptotop oftemperaturescale.• Bottom–Movetheisothermalrange1or2down tobottomoftemperaturescale.

Page 24: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

B - 23 Operating manual – IR Software G

• Semi-Trans–Painttheisothermalarea1or2 usingsemi-transparentcolorscheme.• Ratio–Displaypercentageoftheisothermalarea intheimage(SeeFig.5.2.1topleftcornerofthe rightthermalimage).• Select–Leftclickmouseontheisothermalrange boxtodisplayloweranduppertemperaturevalues.• Move–Movetheisothermalrangealongthetem- peraturescaleupanddownbyclickingandhol- dingtheleftbuttonofmouseontheisothermal rangebox.• Resize–Clickandwhileholdingdowntheleft buttonofmouseontheedgeoftheisothermal range,moveupordowntochangetherange. Youcanalsochangetherangebyenteringtempe- raturevaluesdirectlyintotheupperandlowertem- peratureboxes.

For the PRO, USB, or NET version, you can performisothermalanalysisonindividualtoolarea(e.g.circle,rectangle,andpolygon).

5.3 ImageAdjustment

Youcanchangethecontrastofthethermalimagebychoosingthetemperaturerangeasamappingrangeorspanontoapalette(SeeFigure).RightclickmouseonaselectedthermalimageandclickImageAdjustingfromthepopupmenu.IntheImageAdjustingwindow,clicktheManualradiobutton,adjustingthebluebuttononthescrollbartoselectthetemperaturerangethatyouwouldliketouseasthecolormappingspan.

Theimageadjustingwindowshowsthetemperaturedistributionofathermalimagewithaspecifiedpalettescheme,inwhichyoucanchooseatemperatureran-gebasedonthedistribution.Thehalvedbluetriangle

buttoncanbemovedindependently.Thebluetrianglebuttonisusedtomovetheentirespanleftorright(itmovestherangesetbybothendsofthehalvedbluetriangle buttons). You can also move Brightness orContrastbuttontoadjustimagecolormapping.

5.4 AreaAdjusting

For the PRO, USB, or NET version, you can changebrightness or contrast of a thermal image based ontemperature range within a tool area. (See Fig.) isbasedonarectangletomapcolorscheme.TheAreaadjustingallowsyoutogetaclearerviewofaselectedareayouaremostconcernedwith.

Fortheareaadjusting,rightclickmouseonaselecteddrawing area (e.g. circle, rectangle, or polygon) andclickAreaAdjustingfromthepopupmenu.RightclickmouseonaselecteddrawingareaandclickAreaAd-justingagaintoremovetheareaadjusting.

Page 25: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

G Operating manual – IR Software B - 24

5.5 IRImageSwitch

Youcanreplacethecurrentthermal imagewithano-ther thermal imageby right clicking on it and select“IRImageSwitch”.Thisfeatureisusefulforanalyzingdifferentthermalimageswiththesamesetofanalysistools.

5.6 Fusion

Thefusionfunctionallowsyoutoblendadigitalimage(BMP,CCD,orJPG)withaninfraredimage,whichcanassistinidentifyingobjectsofinfraredimages.

Stepsofmakingfusion:

1.Openathermalimage(.satfile)andadigitalimage (.bmp,.ccd,orjpgfile).

• Click the short- cut;

• Inthefusionsettingwindow,selectathermalimage andadigitalimage.

2.ClicktheOkbutton;

3.Adjustsizeofthedigitalimagewindowtomakeits objectmatchingthermalimage’sobject;

4.Movethethermalimagetomatchtheobjectofthe digitalimage.

5.Adjusttheblendingratiobymovingthescrollbar button;

6.Whenfusioniscompleted,youcansavetheblended imagebyclickingSavebutton.

IfclickYes,youcansavetheblendedimageasa BMPorJPGformatfileandtheblendedimageis showninanalysisorreportwindow.SincetheJPG fileissavedwithtemperaturedata,youcan analyzeitasathermalimageinthePRO,USB,or NETversion.IfclickNo,theblendedimageisshown inanalysisorreportwindow.

ClickCancelbuttontoterminatefusingoperation.

Page 26: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

B - 25 Operating manual – IR Software G

5.7 Snapshot

Youcantakeasnapshotonthecurrentthermal imageandsaveitasanewimagefileinSAT,BMP, orJPGformat.SincetheJPGfileissavedwith temperaturedata,youcananalyzeitasathermal image.

Stepsofsnapshot: - Movemousecursorontothethermalimage andleftclickmousetoselectitascurrent thermalimage; - Clicktheshortcut ; - Choosefiletype(.bmp,.jpg,or.sat)andfile path(SeeFig.5.6); - Giveafilename; - ClicktheSavebutton.

6.0 REPORT

6.1 GeneratingReport

Clicking the Generating Report shortcut entersreportmode.The reportmodeallowsyou tobuild re-portand/ortemplateinanA4papersizearea.Youcanaddthermalimages(.sator.jpgwithtemperaturedata),digitalimages(.ccd,.jpg,or.bmp),tableswithanalysisresults,textcomments,andsoon.

ForthePRO,USB,orNETversion,youcanrightclickandselectpageoperationfunctiontoaddordeleteapage.Note:theDeletePagefunctioncannotdeleteapageifthereisonlyonepage.

YoucanclicktheGeneratingReportshortcut againtoopenmultipletemplates.

Click the button onthetoprightofthedisplaywindowtoclosethereportmode.

6.2 ReportBuild

- Image Addthermalimagesand/ordigitalimagesintothe templateusingOpenIRFileandOpenImagefunctions.

- Text Youcaninserttextintothetemplateasatitleorcomment by clicking shortcut .Youusethe followingtoolstoedittexts.

- Table Clickshortcut toinsertatableintothetemplate. Youcanrightclickonthetabletodothefollowingoperations:

Page 27: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

G Operating manual – IR Software B - 26

a. Delete–deletethecurrenttable b. InsertRowAbove–insertarowabovethecurrentrow c. InsertRowBelow–insertarowbelowthecurrentrow d. DeleteCurrentRow–deletethecurrentrow e. InsertColumntotheLeft–insertacolumntothe leftofthecurrentcolumn f. InsertColumntotheRight–insertacolumntothe rightofthecurrentcolumn g. DeleteCurrentColumn–deletethecurrentcolumn h. AddFreeFormatData–addselectedanalysis dataintothecurrentcell.Afteraddedthedata,you canrightclicktochooseshowingdatavalueor formulafromthepopupmenu.

i. AddFixedFormatData–addselectedanalysis dataofaspecifiedIRimageintothetable.You canchoosetypesoftheanalysisresults.

- IR Image Switch Youcanreplaceaselectedthermalimageusinga newthermalimagebyrightclickingmousebuttonon

athermalimageandselect“IRImageSwitch”fromthe popupmenu.Thenewthermalimagewilluseprevious analysistools.Thisisveryhelpfulforanalyzing differentimageswiththesameanalysismethod.

6.3 SaveReport YoucansavethecurrenttemplatetoaWordformatfile byselecting“SaveReport”inFilemenu.

6.4 OpenIRTFile Openareporttemplatefile(.irt)intoreportmodefor editingorreporting.

6.5 SaveIRTFile Inreportmode,youcansavethecurrentformatted contentsexceptFusionandImageMergingwindows/ containersasareportingtemplateintoafile(.irt). Thetemplatecanbeusedtogeneratebatchreport.

6.6 Print ClickPrintPreviewshortcut topreviewandprint thecurrentreport.

Click Print shortcut toprintthecurrentreport.

7.0 FILE PROCESSING

7.1 Preview Bysingleclickingonathumbnailofathermalrecord file,previewallimagesofthethermalrecord.Bydouble clickingathumbnailoffile,openthethermalimageor recordintoanalysismode.

Page 28: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

B - 27 Operating manual – IR Software G

7.2 Merge

Click Merge shortcut intofilemergingmodeto concatenatethermalrecordfiles.

Youcanselectthermalrecordfilesinordertoconca- tenatethemintoonenewrecordfile.Note:sincethe maximumfilesizeofWindowsXPis2GB,thesoftware willautomaticallysplitthemergingfileintoseveralse- quentialfilesifthemergedfilesizeisgreaterthan2GB. Thesoftwarecanplaythesplitrecordfilesasonefile, whichitcanautomaticallyplaythesplitfilesinorder.

7.3 Edit

ClickEditshortcut intofileeditmode.

You remove unwanted images by selecting imagesandcreateanewthermalrecordfile.

8.0 MONITORING

Real time monitoring is available for USB and NETversion.

8.1 USBMonitor

FortheUSBversion,throughUSBtoconnectanIRca-mera,performrealtimemonitorandanalysisofther-malimage.ThefunctionisavailableforUSBversiononly.See IR cameramanual aboutUSBconnection.Action: menu Monitor => USB Monitor or click theUSBMonitorshortcut:

If theapplicationcannotfindacorrespondingcalib-ratedtemperaturetablefile,itwillaskifyouwanttoaddone.YoucannotconnectaUSBcamerawithoutselectingacalibratedtemperaturetablefile.Choosecamera type and calibrated temperature table filepath,clickOK:

ConnectoneendoftheUSBcabletoyourPC.

PowerupthecameraandwaitseveralsecondsuntiltheverticalcolourbarsappearontheLCD.

ConnecttheotherendofyourUSBcabletotheUSBportofyourinfraredcamerawhilethecolourbarsarestillonthedisplay.

Assoonasthecamerahasbeenidentifiedyouwillbeautomaticallyrequestedtoinstallthedrivers.Proceedasdescribed in thecamera’sUser’sManual.Pleaserefer to your handbook to find more information onyourinfraredcamera.

Proceed as follows once the installation has beensuccessfullyperformed.

Menu Monitor => USB monitor or click on thesymbol

Iftheapplicationisunabletofindafilewithacorre-spondingcalibratedtemperaturetable,thenyouwillbeaskedifwishtoaddone.Thisisnormallyalwaysthe casewhen real-timesoftware is being installedfort hefirst time.You cannot connect aUSBcame-rawithoutfirstassigningittoafilewithacalibratedtemperaturetable.

Youwillfind thecorrespondingcalibrationcurve foryourcameraonthereal-timeCD.OperatingManual

Page 29: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

G Operating manual – IR Software B - 28

–IRSoftware

SaveontoyourPCandrememberthefilepathwhereitwasplaced.SelectthecameratypeandthefilepathforthecalibratedtemperaturetableandclickonOK.

You can update the calibrated temperature table filethroughSystem=>InitialSettings=>Systemtab

USB real time monitor only support Windows XP operation system. You only can connect one USB camera at one time.

8.2 NET-Monitor

For the NET version, through Ethernet to connect oneormultipleNet IRcameras,perform real time monitorandanalysisofthermalimage.Note:SeeIR cameramanualaboutEthernetconnection.

Action:menuMonitor=>NETMonitororclick the NETMonitorshortcut

EnterorselectIPaddressofaNetcameraandselect correspondingcalibrateddatafile,thenclickConnect.

YoucanconnectmultipleNetcamerasatthesame time.Theapplicationsupportssingleanddualvision IRcamera.

8.3 MonitoringScreen

On the monitoring screen, you can control focus andshutterworksthroughRS232orEthernet,take snapshot,adjustspeed,andrecord.

m

Page 30: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

B - 29 Operating manual – IR Software G

AutoFocus

Focusin

Focusout

ShutterWorks

Record

Stop

Snapshot–savecurrentimageintoaJPG,BMP,orSATfile.

Settings

Setplayspeed

9.0 IR RECORDING

ThisfeatureisonlyavailableinUSBandNET version.Recordingsteps: a. ClickSettingsshortcuttosetrecordingparameters.

Youcanspecifyrecordingtime,speed,temperature parameters,andfileformat(SATorAVI).ForAVIformat, youcandecideiftheanalysistoolsarerecorded.You canspecifyrecordingintervalandcycle. b. AdjustIRcamerafocus c. Click Record shortcut tostartrecording. YoucanclickStopshortcut toterminaterecord.

10.0 RECORD PLAY

ThisfeatureisonlyavailableinthePRO,USBand NETversion

Click Open IR File shortcut andselecta thermalrecordfile.

First

Previous

Play

Pause

Next

Last

Setplayspeed

Snapshot–savecurrentimageintoaJPG,BMP,orSATfile

Repeat

Re-record–editandrecordanewfile

Page 31: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

G Operating manual – IR Software B - 30

You can specify file format, compression, and seg-ment

11.0 IMAGE MERGING

TheImageMergingfunctionisavailableinthePRO, USB,andNETversion,whichyoucanmergemultiple thermalimagesortoolareas(e.g.rectangle,circle, andpolygon)intoasinglethermalimage.This functionisusefulforthermalanalysisofalargesite (i.e.wideview)orequipment(e.g.360degree).

Mergingsteps:

• Openthermalimagesthatyouwouldliketo performimagemerging.

• InmenuAction,selectImageMergingorclick Image Merging shortcut ;

• SelectIRcameratypeandmergingcontainersize;

• Onasourcethermalimage,selectthewhole imageoranarea(e.g.rectangle,circle,or polygon),rightclickmousebuttonandselect AddintoMergingFile,whichcopiestheselected wholeimageorareaintothemergingcontainer. Inthecontainer,youcanleftclickmousebutton onanareaandholdmousetomovearound thearea.

• RightclickinthecontainerandselectLayer Adjusting.UseTop,Up,Down,orBottombuttonto adjusttheorderoflayersoftheoverlappedimage areas.

• Todeleteanareafromthecontainer,clickDelete Toolsshortcut selectanareaandleftclick.

• Themergingcontainercannotbeusedforthermal analysis. For thermal analysis, you can save the mergedimageintoaSATorJPGwithtemperature dataformatfile. Rightclickonthemergingcon- tainerandselectSaveMerged Image,whichyou canchooseaSAT,JPG,orBMPformat.

Page 32: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

B - 31 Operating manual – IR Software G

12.0 SYSTEM SETTINGS

12.1SaveFile

- Default Parameters Objectisusedtoselectsavingthecurrentthermal imageorallopenedthermalimagesintofile(s). Temperature Data is for saving temperature data intoJPGformatfileifYesisselected.Italwayssaves thermaldataintoSATformatfile. AnalysisToolsisdeterminedwhetherornottosave analysistoolsordrawingsonthethermalimageinto theJPGandBMPformatfile.Youcannotsaveanalysis toolsintotheSATformatfile. ShowSavingDialogueWindowindicatesthesystem willpopupasavingdialoguewindowforspecifying filenameandpathifitischecked. SaveSettingsistospecifysavingpathforeachfile typeanddefaultfiletype. Default saves the parameters as permanent initial defaultvaluesifitischecked.

12.2Snapshot- Default Parameters:

ObjectofSnapshotchoosestakingsnapshot(s)either from the current thermal imageor fromall opened thermalimages.

NumberofSnapshotchooseshowmanysnapshots totakeononeclick.Thisfunctionisusefulforthermal analysisofrealtimemonitor.

Temperature Data determines whether or not save temperaturedataintoJPGformatfile.Italwayssaves thermaldataintoSATformatfile.

AnalysisToolsdetermineswhetherornotsaveanalysis toolsordrawingsonthethermalimageintotheJPG andBMPformatfile.Youcannotsaveanalysistools intotheSATformatfile.

ShowSavingDialogueWindowshowsasavingdia- loguewindowforspecifyingfilenameandpath.

SaveSettingsspecifiessavingpathforeachfiletype anddefaultfiletype.

Defaultsavestheparametersaspermanentinitialde- faultvaluesifitischecked

12.3Record- Default Parameters:

RecTimesetsdefaultoftotalrecordingtime.

RecSpeedspecifiesnumberofframespersecondto record.

AVISettingsetsdefaultofrecordingformatasAVIformat andfilepath.IfSaveToolsischecked,theanalysistools onthethermalimagewillbesavedintotherecord.

Page 33: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

G Operating manual – IR Software B - 32

SATSettingsetsdefaultofrecordingformatasSATfor-mat,defaultfilepath,andparametersoftemperaturecalculation.

Defaultsavestheparametersaspermanentinitialde-faultvaluesifitischecked.

12.4Re-record- Default Parameters:

AVISettingsetsdefaultof recording formatasAVI formatandfilepath.IfSaveToolsischecked,save analysistoolsintotherecord.IfCompressionische- cked,recordedfilewillbecompressed.

SATSettingsetsdefaultofrecordingformatasSAT format,defaultfilepath,andcompressionoption.

Default saves the parameters as permanent initial defaultvaluesifitischecked.

12.5DataExport- Default Parameters: ExportSettingspecifiesdefaultoffiletypeandpath.

Show Saving Dialogue Window shows a dialogue windowforspecifyingpathandfilename.Otherwise, export data will be saved into a file that name is generatedusingsystemdateandtime. Default saves the parameters as permanent initial defaultvaluesifitischecked.

Page 34: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

B - 33 Operating manual – IR Software G

12.6OpenFile- Default Parameters: Enable Filter set default that enables filter feature whenopenthermalimages. FilterTypespecifiesaruletofilteropenedfiles.

Temperature Setting specifies a temperature range ofthefilter. AdvancedSettingspecifiesadefaultofimageadjust- mentmethod,whetherdisplayminimumormaximum temperatureonthescreen,anddefaultpalette. Defaultsavestheparametersaspermanentinitialde- faultvaluesifitischecked.

12.7System- Default Parameters: SystemSettingspecifiesdefaultofworkingdirectory andcolors. Defaultsavestheparametersaspermanentinitialde- faultvaluesifitischecked.

12.8TemperatureCalibrationEach IRcamerahas its calibrated temperature table.Thetableisrequiredfortemperaturecalculation.Thetablefile(dataload.bin)isprovidedonthesoftwareCDprovidedbyIRcameramanufacturer.ForUSBmonitor, ifthetableofthecurrentcameraisfound,youneedtoaddthetablebeforeyoucanper-formmonitoring.

- Default Parameters: ForNETmonitor,anIPaddressisassociatedwithanIR Camera.ForeachIRcamera,youmustspecifyitstem- peraturecalibrationtablefile.

Page 35: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

G Operating manual – IR Software B - 34

- Default Parameters: UpdateCalibrationallowsusertoupdatetemperature calibrationtableifitischecked. CameraTypespecifiesanIRcameratypeforupdating calibrationtable. CalibrationPathspecifieslocationofacalibrationfile. Applyusesselectedcalibrationtabletoreplacecur- rentone. Defaultsavestheparametersaspermanent initialde- faultvaluesifitischecked.

Page 36: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

B - 35 Operating manual – IR Software G

13.0 VERSION COMPARISON

VERSION FEATURE

PRE STD PRO USB NET

Add into Merging File

Area Adjusting

Batch Report (Using IRT template to generate reports)

Copy to Clipboard

Cursor (Temperature)

Data Export (Trend chart)

Data Export (Whole IR Image)

Distribution (Line)

Drawings (Point, Line, Vernier, Circle, Poly-line, Polygon, Rectangle)

Emissivity (Customize)

Emissivity (List)

File Processing (IR record file merging and editing)

Filter (File open)

Fusion (IR image and digital image)

Generating Report (Single page for STD version)

Histogram (Drawing area)

Image Adjustment

Image Merging

Image Subtarction

IR Camera Model

IR Image Switch

Isothermal Area (Drawing area)

Isothermal Area (Whole IR Image)

Language

Max Temperature

Min Temperature

Multiple Distributions

Multiple Trends

NET Monitor

Open Image (JPG, BMP)

Open IR File (CCD, JPG, SAT)

Open IRT File (Open a report template)

Open IRW File (Open a saved analysis working space)

Original Size

Partial Trend (Record)

Palette (Drawing area)

Palette (Whole IR image)

Play (Record)

Play Audio

Record (SAT, AVI)

Page 37: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

G Operating manual – IR Software B - 36

13.0 VERSIONSVERGLEICH

VERSION FEATURE

PRE STD PRO USB NET

Add into Merging File

Area Adjusting

Batch Report (Using IRT template to generate reports)

Copy to Clipboard

Cursor (Temperature)

Data Export (Trend chart)

Data Export (Whole IR Image)

Distribution (Line)

Drawings (Point, Line, Vernier, Circle, Poly-line, Polygon, Rectangle)

Emissivity (Customize)

Emissivity (List)

File Processing (IR record file merging and editing)

Filter (File open)

Fusion (IR image and digital image)

Generating Report (Single page for STD version)

Histogram (Drawing area)

Image Adjustment

Image Merging

Image Subtarction

IR Camera Model

IR Image Switch

Isothermal Area (Drawing area)

Isothermal Area (Whole IR Image)

Language

Max Temperature

Min Temperature

Multiple Distributions

Multiple Trends

NET Monitor

Open Image (JPG, BMP)

Open IR File (CCD, JPG, SAT)

Open IRT File (Open a report template)

Open IRW File (Open a saved analysis working space)

Original Size

Partial Trend (Record)

Palette (Drawing area)

Palette (Whole IR image)

Play (Record)

Play Audio

Record (SAT, AVI)

Page 38: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52
Page 39: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52
Page 40: tro tr ba irreport 01 10 GB - trotec.com - TROTEC · TROTEC® GmbH & Co. KG • Grebbener Straße 7 • D-52525 Heinsberg Tel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52

TROTEC®GmbH&Co.KG • Grebbener Straße 7 • D-52525 HeinsbergTel.: +49 (0) 24 52 / 962 - 400 • Fax: +49 (0) 24 52 / 962 - 200www.trotec.de • E-Mail: [email protected]