typical airlift pump configuration for the …
TRANSCRIPT
LL
AAiirr IInnjjeeccttiioonn DDeepptthh((SS == 44**LL))
AAiirr DDeelliivveerryy PPrreessssuurree((LL ++ SS))
TTaannkkWWaatteerr LLeevveell
AAiirr FFlloowwrraattee ((QQAAiirr == 00..227755**QQff))
SSccrreeeenn EElleevvaattiioonniiss 88”” bbeellooww TTaannkkWWaatteerr LLeevveell
HH
Filter ID
Flowrate (Qf, gpm)
Outlet Pipe Size (in)
FlowVelocity (ft/s)
FilterHeight (in)
Air Lift Requirement (in)
Air Injection Depth (in)
Air DeliveryPressure (in) Air Flowrate
(QAir, scfm) (Ddown) (Dup) (Vdown) (Vup) (H) (L) (S) (L+S)
PG-6000 45 (2) x 3 (2) x 3 1.02 1.02 47 8 32 40 12 PG-12000 90 (2) x 4 (2) x 4 0.97 0.97 54 8 32 40 25
QQff
DDddoowwnn
DDuupp
AAiirrlliifftt PPuummpp
PPoollyyGGeeyysseerr®® BBeeaadd FFiilltteerr
TYPICAL AIRLIFT PUMP CONFIGURATION FOR THE POLYGEYSER® 6OOO and 12OOO
AST Aquaculture Systems Technologies, LLC2120 North 3rd StreetBaton Rouge, LA 70802www.as�ilters.com
info@as�ilters.comPhone: 504.837.5575
Toll-Free:800.939.3659Fax: 504.837.5585