uitgezocht design proposal erf 54 ıuitgezochtestate.com/images/documents/54-plans.pdf · sans...

5
UITGEZOCHT DESIGN PROPOSAL ERF 54 294 MAIN ROAD ı PAARL P.O. BOX 7158 ı 7646 t: 021 872 4536 ı f: 021 872 4100 ı m: 082 771 5902 ı e: [email protected] PrArch SACAP reg. no. 7685

Upload: others

Post on 14-Mar-2021

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: UITGEZOCHT DESIGN PROPOSAL ERF 54 ıuitgezochtestate.com/images/documents/54-plans.pdf · SANS 10142-1. - Plumbing installation to comply with local authority requirements and SANS

UITGEZOCHT DESIGN PROPOSALERF 54

294 MAIN ROAD ı PAARLP.O. BOX 7158 ı 7646

t: 021 872 4536 ı f: 021 872 4100 ı m: 082 771 5902 ı e: [email protected]

PrArch • SACAP reg. no. 7685

Page 2: UITGEZOCHT DESIGN PROPOSAL ERF 54 ıuitgezochtestate.com/images/documents/54-plans.pdf · SANS 10142-1. - Plumbing installation to comply with local authority requirements and SANS

UITGEZOCHT DESIGN PROPOSALERF 54

294 MAIN ROAD ı PAARLP.O. BOX 7158 ı 7646

t: 021 872 4536 ı f: 021 872 4100 ı m: 082 771 5902 ı e: [email protected]

PrArch • SACAP reg. no. 7685

Page 3: UITGEZOCHT DESIGN PROPOSAL ERF 54 ıuitgezochtestate.com/images/documents/54-plans.pdf · SANS 10142-1. - Plumbing installation to comply with local authority requirements and SANS

294 MAIN ROAD ı PAARLP.O. BOX 7158 ı 7646

t: 021 872 4536 ı m: 082 771 5902 ı e: [email protected]

PrArch • SACAP reg. no. 7685

DRAWING NO. 54UIT-C002

SKETCH COUNCIL CONSTRUCTION

SCALE:

●●

PROJECT REF. 62-54UIT- 54 UITGEZOCHT

DRAWN: CHECKED:A. J v VUURENCANT 21888

A. MARAISPR.ARCH 7685

AS SHOWN DATE: 27.06.2016

PROJECT:PROPOSED NEW DWELLINGFarm 811 portion 54CLIENT:UITGEZOCHT ESTATE PTY. LTD.

NOTES

NOTES

- THE DESIGN ON THIS DRAWING IS COPYRIGHT AND REMAINS THE PROPERTY OF ABRÉ MARAIS ARCHITECTS.- ALL WORK IS TO BE CARRIED OUT IN ACCORDANCE WITH THE N.B.R SANS 10400 AND LOCAL AUTHORITY REGULATIONS.- CONTRACTOR, SUB-CONTRACTORS & SPECIALIST SUB-CONTRACTORS TO CHECK ALL DIMENSIONS AND LEVELS ON SITE PRIOR TO ANY CONSTRUCTION.- ANY DISCREPANCIES TO BE IMMEDIATELY REPORTED TO THE ARCHITECT FOR CLARIFICATION.- USE FIGURED DIMENSIONS, DO NOT SCALE.- SETTING OUT TO BE DONE FROM THE SURVEYOR'S PEGS.- CONTRACTOR, SUB-CONTRACTORS & SPECIALIST SUB-CONTRACTORS TO ENSURE WORKS TENDERED UPON COMPLY WITH ALL RELEVANT SAFETY AND/OR HEALTH STANDARDS. ANY DEVIATIONS REQUIRED TO ARCHITECTS DESIGN AND DETAIL DRAWINGS TO ENSURE LEGAL/SAFETY COPLIANCE ARE TO BE QUALIFIED AT TENDER STAGE.

ENERGY SAVING NOTES

- Geyser to be coupled to solar panels, to be wrapped with Isover non- combustable geyser insulation. Insulate hotwater piping where not built into wall, insulate all exposed hotwater pipes with Isover to a minimum R-value of 1.00.- Water saving - water saving or low flow shower heads, dual flush toilets, tap aerators. Energy saving bulbs to be used in house.- Isotherm to be provided to specialist contractor as per SANS 10400-XA.- All roofs to be insulated so that a min. R-value of 3.7 is achieved (to comply with SANS 10400-XA:2011: 4.4.5.1.). Type of insulation to be flexible polyester blanket (Isotherm or similar approved) with a density of 11.5kg/m³ installed as per SANS 204:2011 thickness min. 160mm and R- value of a min. 3.3 (for main roof) and min. 3.35 (for lean-to roofs).- Electrical installation to comply with local authority requirements and SANS 10142-1.- Plumbing installation to comply with local authority requirements and SANS 10400.- Natural ventilation to comply with municipal regulations and SABS0400 in terms of min. 5% floor area.- Natural light to comply with municipal regulations and SABS 0400 in terms of min. 10% floor area.

60010

0 700

1 40

0 2 20

5

min

. 1 0

00

1 24

5

2 10

0

1 80

0

255

300

1 80

01

410

1 20

0

600

1 20

0

7 50

0

ROOF CONSTRUCTION 1: 45o

Roof pitch: Main building.

ROOF CONSTRUCTION 2: 3o Roofpitch: Covered Stoep with Braai:

WATER PROOFING CONSTRUCTION:

D04

V01 V01

W01

6.260 ▼

3.060 ▼

FCL: 142.300

boun

dary

line

boun

dary

line

▼ 6.260

▼ 3.060

FCL: 142.300B

NQ

F

600x200concrete foundation

F F

existing foundation

exis

ting

boun

dary

wal

l

Q

ANGL: 141.3401.000 ▲ ▲ 1.000

Fascia, gutters, down pipes & bargeboards as per GENERAL NOTES:

TIMBER COLUMN CONSTRUCTION:

Aluminium louvre vent asper WINDOW SCHEDULE:

Recess in wall 15mmdeep. Wall painted as per

Uitgezocht Guidelines:

Tophung Aluminiumwindow as per WINDOW

SCHEDULE:

Fascia, gutters, down pipes & bargeboards as per GENERAL NOTES:

concrete pavers as per client.

Walls plastered & painted asper Uitgezocht Guidelines:

Walls plastered & painted as perUitgezocht Guidelines:

Boundary walls plastered &painted as per Uitgezocht

Guidelines:

Aluminium Door as per DOOR SCHEDULE:

Turbo Cowl to be installed by specialistmin 1000mm from roof finish, all tocomply with SANS 10400, Part T.

chimney plastered and paintedas per GENERAL NOTES:

80mm thick (15mm deep) recess inchimney 150mm from top of brickwork.

1 20

090

0

600

1 50

0

525

600

1 50

096

0

1 80

02 18

0

5 74

5

6 26

5

410

240

690

ROOF CONSTRUCTION 1: 45o Roof pitch: Main building.

steel roof capping, 90o profile, with toe closures.

ROOF CONSTRUCTION 2: 3o Roofpitch: Covered stoep with braai.

G01

D05 W04 W03W02W02

900x200concrete foundation

6.260 ▼

3.060 ▼

FCL: 142.300

▼ 6.260

▼ 3.060

FCL: 142.300

existing foundation

boun

dary

line

Q

exis

ting

boun

dary

wal

l

F

UANGL: 141.340

600x200concrete foundation

600x200concrete foundation

1.000 ▲ ▲ 1.000

7 50

0

Tophung Aluminium window as per WINDOW SCHEDULE:

Fascia, gutters, down pipes & barge boards as per GENERAL NOTES:

concrete pavers as per client.

Walls plastered & painted as perUitgezocht Guidelines:

80mm thick (15mm deep) recess inchimney 255mm from top of brickwork.

Tophung Aluminium window as per WINDOW SCHEDULE:

38x38mm hardwood timber slats fixedto angle irons, fixed to walls.

TIMBER COLUMN CONSTRUCTION:

Turbo Cowl to be installed by specialist min 1000mm fromroof finish, all to comply with SANS 10400, Part T.

chimney plastered and painted as per GENERAL NOTES: Aluminium single hung door as perDOOR SCHEDULE:

WALL CONSTRUCTION 3:

boun

dary

line

900

2 10

0

900

1 20

0

3 06

02

200

1 97

080

150

8025

5

4 30

5

200

200

240

7 50

0

ROOF CONSTRUCTION 1: 45o Roof pitch: Main building.

steel roof capping, 90o profile, with toe closures.

ROOF CONSTRUCTION 2: 3o Roofpitch: Covered stoep with braai.

W01W03 W02 W02W02

6.260 ▼

3.060 ▼

FCL: 142.300

▼ 6.260

▼ 3.060

FCL: 142.300

existing foundation

boun

dary

line

boun

dary

line

exis

ting

boun

dary

wal

l

900x200concrete foundation

12

3

U ANGL: 141.340600x200concrete foundation1.000 ▲ ▲ 1.000

Walls plastered & painted as per Uitgezocht Guidelines:Tophung Aluminium window as per WINDOW SCHEDULE:

Fascia, gutters, down pipes & bargeboards as per GENERAL NOTES:

concrete pavers as per client.

80mm thick (15mm deep) recess inchimney 255mm from top of brickwork.

Tophung Aluminium window as per WINDOW SCHEDULE:

38x150mm hardwood timber slatsfixed to angle irons, fixed to walls.

TIMBER COLUMN CONSTRUCTION:

Walls plastered & painted as perUitgezocht Guidelines:

2 18

054

5

255

1 97

080

150

3 51

01

200

1 80

0 2 72

533

5

600

1 20

0

1 24

5

2 10

0

7 50

0

ROOF CONSTRUCTION 1: 45o Roof pitch: Main building.

D01D06

V01

V01

W01

6.260 ▼

3.060 ▼

FCL: 142.300

▼ 6.260

▼ 3.060

FCL: 142.300

boun

dary

line

boun

dary

line

N

Q

T

N

B

F

ANGL: 141.3401.000 ▲ ▲ 1.000

Fascia, gutters, down pipes & barge boards as per GENERAL NOTES:

Aluminium louvre vent as per WINDOW SCHEDULE:

Recess in wall 15mm deep. Wall painted as per Uitgezocht Guidelines:

Tophung Aluminium window as per WINDOW SCHEDULE:

Fascia, gutters, down pipes & barge boards as per GENERAL NOTES:

concrete pavers as per client.

Walls plastered & painted asper Uitgezocht Guidelines:

Walls plastered & painted as per Uitgezocht Guidelines:Boundary walls plastered & painted as per Uitgezocht Guidelines:

Aluminium Garage Door as per DOOR SCHEDULE:

Turbo Cowl to be installed by specialistmin 1000mm from roof finish, all tocomply with SANS 10400, Part T.

chimney plastered and paintedas per GENERAL NOTES: 80mm thick (15mm deep) recess in chimney 150mm from top of brickwork.

Aluminium Entrance Door as per DOOR SCHEDULE:

WALL CONSTRUCTION 3:

N

3 23

012

620

5 54

5

1 815

3 99

5

12 075

ERF 51

ERF 55

ERF

73 (S

TREE

T)

ERF 5334.330m BOUNDARY LINE

1 500 mm building line

1 50

0 m

m b

uild

ing

line

21.3

90m

BO

UND

ARY

LIN

E

31.390m BOUNDARY LINE

17.9

40m

BO

UND

ARY

LIN

E

4.790m

EXISTING BOUNDARY WALL

5 00

0 m

m G

ara

ge b

uild

ing

line

4 00

0 m

m M

ain

bui

ldin

g lin

e

EXIS

TING

BO

UND

ARY

WA

LL

1 500 mm building line

2m servitude line

NEW DWELLING(main house)

ERF 54covered

stoep

coveredentrance

timber slats

A58

A14

A55

A57

A54

dpc

dpc

45° 45°

525

600

1 50

098

5

2 10

0

2 10

0

4 80

5

2 94

5

1 00

0

1 01

5

7 50

0

ROOF CONSTRUCTION 1: 45o Roof pitch: Main building.

ROOF CONSTRUCTION 2: 3o Roofpitch: Covered Stoep with Braai:

WATER PROOFING CONSTRUCTION:CEILING CONSTRUCTION 1:

CEILING INSULATION 1:

WALL CONSTRUCTION 1:

WALL CONSTRUCTION 3:

WALL CONSTRUCTION 2:FOUNDATION WALL CONSTRUCTION:FOUNDATION CONSTRUCTION:

FLOOR CONSTRUCTION 1:

D04

V01

D02

V01

W02

FCL: 142.250

covered stoep with braai

mitek designrooftrusses

main bedroom

NGL

FCL: 142.300

▼ 3.0603.060 ▼

FCL: 142.300

▼ 6.2606.260 ▼

▼ 2.6052.605 ▼

700x250mm 700x250mm 450x150mm

existing foundation

B

N Q

600x200mm600x200mm

Q

FCL: 142.300

ANGL: 141.340▲ 1.0001.000 ▲

Fascia, gutters, down pipes & barge boards as per GENERAL NOTES:Aluminium louvre vent as per WINDOW SCHEDULE:

Tophung Aluminium window as per WINDOW SCHEDULE:

Interior walls plastered & painted as per client: Aluminium Door as per DOOR SCHEDULE:

Turbo Cowl to be installed by specialistmin 1000mm from roof finish, all tocomply with SANS 10400, Part T.

dpc

dpc dpc

dpc

45°45°

2 10

0

1 20

090

098

5

2 65

5

2 60

52

855

3 11

0

3 06

0

5 26

0

5 74

0

150150150150

7 50

0

ROOF CONSTRUCTION 1:45o Roof pitch: Main building.

ROOFCONSTRUCTION

3: 3o Concrete roof:

WATERPROOFING

CONSTRUCTION: CEILING CONSTRUCTION 1:CEILING INSULATION 1:

WALL CONSTRUCTION 1:

WALL CONSTRUCTION 3:FOUNDATION WALLCONSTRUCTION:FOUNDATION CONSTRUCTION:

FLOORCONSTRUCTION 1:

V01V01

D02 W03D03

NGLFCL: 142.300

▼ 3.0603.060 ▼

FCL: 142.300

▼ 6.2606.260 ▼

▼ 2.6052.605 ▼

FCL: 142.250 FCL: 142.300

double garage bedroom 1foyer

mitek designrooftrusses

mitek designrooftrusses

700x250mm 700x250mm 700x250mm 700x250mmexisting foundation

600x200mmANGL: 141.340

▲ 1.0001.000 ▲

1 80

0

Fascia, gutters, down pipes &barge boards as perGENERAL NOTES:

Tophung Aluminium window asper WINDOW SCHEDULE:Interior walls plastered &painted as per client:

Halfhour fireTimberDoor as per DOOR

SCHEDULE:

S O U T H E L E V A T I O NSCALE 1:100

N O R T H E L E V A T I O NSCALE 1:100

E A S T E L E V A T I O NSCALE 1:100

W E S T E L E V A T I O NSCALE 1:100

S I T E P L A NSCALE 1:200

S E C T I O N AASCALE 1:100

S E C T I O N BBSCALE 1:100

Page 4: UITGEZOCHT DESIGN PROPOSAL ERF 54 ıuitgezochtestate.com/images/documents/54-plans.pdf · SANS 10142-1. - Plumbing installation to comply with local authority requirements and SANS

294 MAIN ROAD ı PAARLP.O. BOX 7158 ı 7646

t: 021 872 4536 ı m: 082 771 5902 ı e: [email protected]

PrArch • SACAP reg. no. 7685

DRAWING NO. 54UIT-C001

SKETCH COUNCIL CONSTRUCTION

SCALE:

●●

PROJECT REF. 62-54UIT- 54 UITGEZOCHT

DRAWN: CHECKED:A. J v VUURENCANT 21888

A. MARAISPR.ARCH 7685

AS SHOWN DATE: 27.06.2016

PROJECT:PROPOSED NEW DWELLINGFarm 811 portion 54CLIENT:UITGEZOCHT ESTATE PTY. LTD.

NOTES

NOTES

- THE DESIGN ON THIS DRAWING IS COPYRIGHT AND REMAINS THE PROPERTY OF ABRÉ MARAIS ARCHITECTS.- ALL WORK IS TO BE CARRIED OUT IN ACCORDANCE WITH THE N.B.R SANS 10400 AND LOCAL AUTHORITY REGULATIONS.- CONTRACTOR, SUB-CONTRACTORS & SPECIALIST SUB-CONTRACTORS TO CHECK ALL DIMENSIONS AND LEVELS ON SITE PRIOR TO ANY CONSTRUCTION.- ANY DISCREPANCIES TO BE IMMEDIATELY REPORTED TO THE ARCHITECT FOR CLARIFICATION.- USE FIGURED DIMENSIONS, DO NOT SCALE.- SETTING OUT TO BE DONE FROM THE SURVEYOR'S PEGS.- CONTRACTOR, SUB-CONTRACTORS & SPECIALIST SUB-CONTRACTORS TO ENSURE WORKS TENDERED UPON COMPLY WITH ALL RELEVANT SAFETY AND/OR HEALTH STANDARDS. ANY DEVIATIONS REQUIRED TO ARCHITECTS DESIGN AND DETAIL DRAWINGS TO ENSURE LEGAL/SAFETY COPLIANCE ARE TO BE QUALIFIED AT TENDER STAGE.

ENERGY SAVING NOTES

- Geyser to be coupled to solar panels, to be wrapped with Isover non- combustable geyser insulation. Insulate hotwater piping where not built into wall, insulate all exposed hotwater pipes with Isover to a minimum R-value of 1.00.- Water saving - water saving or low flow shower heads, dual flush toilets, tap aerators. Energy saving bulbs to be used in house.- Isotherm to be provided to specialist contractor as per SANS 10400-XA.- All roofs to be insulated so that a min. R-value of 3.7 is achieved (to comply with SANS 10400-XA:2011: 4.4.5.1.). Type of insulation to be flexible polyester blanket (Isotherm or similar approved) with a density of 11.5kg/m³ installed as per SANS 204:2011 thickness min. 160mm and R- value of a min. 3.3 (for main roof) and min. 3.35 (for lean-to roofs).- Electrical installation to comply with local authority requirements and SANS 10142-1.- Plumbing installation to comply with local authority requirements and SANS 10400.- Natural ventilation to comply with municipal regulations and SABS0400 in terms of min. 5% floor area.- Natural light to comply with municipal regulations and SABS 0400 in terms of min. 10% floor area.

N8

100

12 070

4 760

6 54

5

14 100

3 00

0

ROO

F C

ON

STRU

CTIO

N 2

:

3°45°45°45°

45°45°45°

45° 45° 45°

45° 45° 45°

ROOF CONSTRUCTION 1:

ROOF CONSTRUCTION 1:

ERF 54

ERF 55

timber slats shading

ERF 51

ERF

73 (s

treet

)

ERF 5334.330m BOUNDARY LINE

1 500 mm building line

1 50

0 m

m b

uild

ing

line

21.3

90m

BO

UND

ARY

LIN

E

31.390m BOUNDARY LINE

17.9

40m

BO

UND

ARY

LIN

E

4.790m BOUNDARY LINE

EXISTING BOUNDARY WALL

5 00

0 m

m G

ara

ge b

uild

ing

line

4 00

0 m

m M

ain

bui

ldin

g lin

e

1 500 mm building line

EXIS

TING

BO

UND

ARY

WA

LL

turbo cowl

turbo cowlconcrete roof to fall 1:50 towards fullbore outlet.

concrete roof to fall 1:50 towards fullbore outlets.

D06

W03

W01

W01

W01W03 W02 W02W02

D04

W04 W02D05

D01

D02D02

D02D02

D02

G01

W02

D03

G01

FW

MD

W

N

RG

280 3 900 110 1 800 110 3 600 110 2 100 110 1 500 110 3 490 280

11 690

280

6 88

028

03

900

280

440505

280 6 000 280 2 400 230 6 000 280

6 560 8 910 3 700 350 350

280

7 88

028

03

900

280

4 25

5

1 40

511

03

015

1 35

0

15 470 2 030

1 48

01

500

1 48

02

580

3 60

098

01

000

11 6

20

1 48

01

500

1 48

01

600

880

4 80

088

0

2 655 750 935 750 2 160 1 500 1 835 750 2 395 750 3 020 1 670

17 500

4 315 750 1 495210

600 900 7 200

500 300

230 630 1 200 570 230

110

1 13

011

0

600

230

1 66

528

0

230

1 00

060

011

02

191

280

3 83

03

545

3 54

5

440

2 04

044

0

17 7

7050

0

3 090 750

12 220 5009 915

8 10

0

4 46

06

560

12 6

20

A

A

BB

wc

bath

showerwc walk-in-

shower

linnen

bic

bicbic

bic

coun

ter

stov

e

braaishelves

hwb withvanity

2xhwb withvanity

B

B

C

C

A

A

II

N

N

P

Q

sfireplace

dres

sing

E

34.330m BOUNDARY LINE

1 500 mm building line

1 50

0 m

m b

uild

ing

line

21.3

90m

BO

UND

ARY

LIN

E

31.390m BOUNDARY LINE

17.9

40m

BO

UND

ARY

LIN

E

4.790m BOUNDARY LINE

Q

EXISTING BOUNDARY WALL

G01

RC beam as per Engineer'sdetails & specifications.

RC beam as per Engineer'sdetails & specifications.

F

ERF 54

NGL: 140.030

NGL: 142,400

NGL: 142.700

50mmstep

5 00

0 m

m G

ara

ge b

uild

ing

line

4 00

0 m

m M

ain

bui

ldin

g lin

e

NGL: 140.225

123

12

U

U

F

NGL: 142.700

EXIS

TING

BO

UND

ARY

WA

LL

2m servitude line

AVERAGE NGL:

140.225 +142.400 +142.700 +140.030 =565.355 / 4 =141.340

141.340 + 7.50 =148.840

STORMWATER,SEWERAGE &ELECTRICALLAYOUT on

DRAWING 54UIT-C003

Line fireplace with firebricks on walls andfloor. Built in Home Fires

steelhood in fireplace and finish withturbo cowl on chimney stack.

BATHROOM 1F: TilesA: 4,50 m2

FCL: 142 300

SCULLERYF: TilesA: 3,54 m2

FCL: 142 300

KITCHENF: TilesA: 10,21 m2

FCL: 142 300

LIVING AREAF: TilesA: 43,01 m2

FCL: 142 300

MAIN ENSUITEF: TilesA: 9,24 m2

FCL: 142 300

FOYERF: TilesA: 10,18 m2

FCL: 142 300

DOUBLE GARAGEF: ScreedA: 36,00 m2

FCL: 142 250

COVEREDSTOEP withBRAAIF: Non-slip TilesA: 26,96 m2

FCL: 142 250

BEDROOM 1F: CarpetA: 15,21 m2

FCL: 142 300

MAIN BEDROOMF: CarpetA: 17,68 m2

FCL: 142 300

BEDROOM 1F: CarpetA: 14,04 m2

FCL: 142 300

COVEREDENTRANCEF: Non-slip TilesA: 3,20 m2

FCL: 142 250

DRYING YARDF: pavementA: 16,39 m2

FFL: 142 100

DRIVE WAYF: pavementA: 29,18 m2

A58

A14

A55

A57

A54

A

B

C

I

L

M

Paving to fall away from building onto vegetation or nearestcatchpit to connect with stormwater disposal, to comply withSANS 10400, Part R.

Allow 50mm wheather step.

60 min. Firewall between Garage & dwelling. To comply withSANS 10400, Part T.

40mm concrete-screed step for base of fireplace, finish as perowner.

230mm brick boundary wall @ max. 1 800mm from NGL withcontrol joints every 10m. Walls to be plastered and painted as perUitgezocht guidelines.

Extractor fan to be connected with light switch, to comply withSANS 10400, Part O.

New Bulkhead detail as per Section drawing.

New columns as per detailed drawing. Columns construction asper CONSTRUCTION NOTES:

New braai & Fireplace to comply with SANS 10400, Part V.

No obstruction on sidewalk.

Gate to be equiped with self closing selflatching mechanism, allto comply with SANS 10400, Part D.

Main Gate to be electronically opperated with self closing selflatching mechanism, all to comply with SANS 10400, Part D.

Stove Feature walls, ROK bricks with white grout cement infill. Asper Section.

230mm brick boundary wall @ max. 1 200mm from NGL withcontrol joints every 10m. Walls to be plastered and painted as perUitgezocht guidelines.

230mm brick wall retaining loose earth filling. Walls to beplastered and painted as per Uitgezocht guidelines.

N

P

Q

R

S

F

D

T

U

Armed AttackBurglary & VandalismHuman Impact

NOTE: Toughened safety glass is permanently marked. Refer matrix of glassmanufacturers for relevant identification markings.

Laminated glass is marked by etching, engraving or sand blasting. The markconsists of the glaziers name or initialsm together with the relevant glass code.

-Multi Laminate Bullet-Resisting Glass of-PVB and/or Resin

-Laminates-Any other glazing

materials complying with the reqirements of

SANS 1263 Part III.

-HI PVB Laminate-Any other glazing

materials complying with the reqirements of SANS 1263 Part II.

-NS PVB Laminate-HPR PVB Laminate

-Resin Laminate-Toughened Safety Glass

-Any other glazing materials complying with

the reqirements of SANS 1263 Part I.

Types of glazing materials

32

Glass CodeGlass Code

1

Glass Code

SANS 10137 - The installation of glazing in buildings:

5.5.2 Identification of safety and security glazing material:All safety glazing material (individual panes) shall be permanently marked.Such marking to be visible after installation (glazing).NOTE: The onus rests with the installer of the safety glazing material toensure that the permanent mark is applied.

5.5.6 Horizontal and sloped galzing (inter alia):Safety glazing materials are to be used in horizontal and sloped glazingapplications. Toughened safety glass or wired glass panes may be usedwhen individual panes are formed all round. Wired glass with two-edgesupport may be used in vertical glazing in saw-tooth roofs.NOTE: Wired glass is not a safety glass unless it conforms to SANS 1263-1

The permanent markings on safety glass materials:

Armed AttackBurglary & VandalismHuman Impact

NOTE: Toughened safety glass is permanently marked. Refer matrix of glassmanufacturers for relevant identification markings.

Laminated glass is marked by etching, engraving or sand blasting. The markconsists of the glaziers name or initialsm together with the relevant glass code.

-Multi Laminate Bullet-Resisting Glass of-PVB and/or Resin

-Laminates-Any other glazing

materials complying with the reqirements of

SANS 1263 Part III.

-HI PVB Laminate-Any other glazing

materials complying with the reqirements of SANS 1263 Part II.

-NS PVB Laminate-HPR PVB Laminate

-Resin Laminate-Toughened Safety Glass

-Any other glazing materials complying with

the reqirements of SANS 1263 Part I.

Types of glazing materials

32

Glass CodeGlass Code

1

Glass Code

SANS 10137 - The installation of glazing in buildings:

5.5.2 Identification of safety and security glazing material:All safety glazing material (individual panes) shall be permanently marked.Such marking to be visible after installation (glazing).NOTE: The onus rests with the installer of the safety glazing material toensure that the permanent mark is applied.

5.5.6 Horizontal and sloped galzing (inter alia):Safety glazing materials are to be used in horizontal and sloped glazingapplications. Toughened safety glass or wired glass panes may be usedwhen individual panes are formed all round. Wired glass with two-edgesupport may be used in vertical glazing in saw-tooth roofs.NOTE: Wired glass is not a safety glass unless it conforms to SANS 1263-1

The permanent markings on safety glass materials:

AREA OF PROPOSED DWELLING

ERF = 733.28 m²COVERAGE = 30.01 %

GROUND FLOOR = 148.95 m²DOUBLE GARAGE = 41.81 m²

GROUND FLOOR TOTAL = 190.76 m²

COVERED ENTRANCE = 3.20 m²STOEP with BRAAI = 26.96 m²

TOTAL FOOTPRINT m² = 220.92 m²

CONSTRUCTION NOTES:ROOF CONSTRUCTION 1: MAIN ROOF: 45° RoofpitchArmour grey Alumbond corrugated roof sheeting @ 45°, 0,5mm thick on 3 layerroofing underlay, on 76x50 SA Pine timber purlins @ max. 900mm centres fixed to152x38mm SA Pine, Mitek designed roof trusses @ max. 760mm centres fixed with a114x50mm wallplate tied down by hoop irons @ 750mm centres, 5 brick coursesdeep. All Roofs to comply with SANS 10400-L:2011.

ROOF CONSTRUCTION 2: GARAGE: 3° RoofpitchFinish: Roof sheeting to be Brownbuilt Klip-Lok 406 0,5mm thick light industrial Z275spelter galvanised steel sheeting with Globalcoat finish to one side and half coatGlobalcoat Grey other side and accessories, @ 3° pitch (colour: Armour Grey tomatch Main roof) fixed to 76x50mm SA pine timber purlins @ max. 1200mm centresfixed to 114x38 SA pine @ max. 900mm centres fixed to walls and fixed on228x50mm SA pine timber beam fixed on timber columns (elsewhere specified), all inaccordance with the manufacturer's recommendations. Ends wrapped in brickgrip. AllRoofs to comply with SANS 10400-L:2011.

ROOF CONSTRUCTION 3: CONCRETE ROOF:Concrete Roof as per engineer's details and specifications.Waterproofing: One layer derbigum SP4 waterproofing membrane, with 75mm sidelaps and 100mm end laps, sealed to primed surface to falls and crossfalls by "torch-fusion" finished with two coats bituminous aluminium paint. Waterproofing to beinstalled by an approved derbigum contractor under a ten year guarantee.Downpipes: Downpipe to be 100mmØ uPVC fixed in brick column with outlet intocatch pit.

CHIMNEY CONSTRUCTION:Line firebricks on concrete slab, against side- & back walls, stacked in stack bond.Built in Homefires steelhood in braai and fire place and finished with turbo cowl onchimney stack, all to comply with SANS 10400, Part T.

WATERPROOFING CONSTRUCTION: COVERED STOEP with BRAAI:Headwall - and Sidewall flashings with Counter flashings are to be counterflashedwith 150mm wide Geoflex acrylic coating, including white polypropylenereinforcement. Waterproofing to be installed by an Approved Derbigum Contractor.

CEILING INSULATION:Isover flexible 130mm thick Aerolite non-combustible lightweight fibreglass reinforcedinsulation blanket (Class 1 fire index rating), closely fitted with ends butted firmlybetween tie beams and laid loose on top of brandering between roof timbers, all inaccordance with manufacturer's recommendations.

CEILING CONSTRUCTION 1: MAIN ROOF:Finish: Gyproc 6,4mm RhinoCeil Value gypsum flush plastered ceiling with squareedged Rhinoboard fixed print side up with 32mm galvanised clout or semi-clout nails@ max. 150mm centres fixed to 38x38mm SA Pine timber battens @ max. 300mmcentres in one direction. All joints to be covered with Rhinotape fixed over joints andthen plastered with 3mm to 6mm thick Rhinolite gypsum skim plaster, all fixed totrusses, all in accordance with the manufacturer's recommendations. Ceiling to bepainted.Cornice: As per GENERAL NOTES.

CEILING CONSTRUCTION 2: CONCRETE ROOF:Ceiling to be finished with cement plaster and to be painted as per clientsspecifications.

TIMBER COLUMN CONSTRUCTION:COLUMN: 2 x 152x38mm Hardwood timber column posts with 76x50mm timber blockpieces (top&bottom), fixed on 5mm thick galv.steel plate with 30mm turnup. 12mmØgalv. steel rod fixed to 10mm galv. steel plate bolted to concrete floor slab.

WALL CONSTRUCTION 1:R.O.K Bricks Cavity: 50mm The inner and outer cavity walls to be tied with pvsbutterfly wall ties; 5 per sqm. Cavity to be filled with concrete from foundations up toground floor dpm. Closed cavity 2 courses below wall plate. Stepped dpm: 375micronembossed Brick grip at floor level, horizontal and vertical to doors and windows.Provide weep holes @600mm c/c max.All Walls to comply with SANS 10400-K:2011.

WALL CONSTRUCTION 2:R.O.K Bricks single skin: laid in running bond to be plastered and painted as perClients needs and specifications. All Walls to comply with SANS 10400-K:2011.

WALL CONSTRUCTION 3:R.O.K Bricks double skin: laid in running bond to be plastered and painted as perClients needs and specifications. All Walls to comply with SANS 10400-K:2011.

PARAPET WALLS:All parapet walls with cavities higher than 500mm to be filled with concrete or brickforce in every 5th brick layer. All Walls to comply with SANS 10400-K:2011.

TIMBER SLATS @ covered entrance:Hardwood timber slats 32x32mm fixed into walls spaced 40mm apart. Laid indirection as shown on Roof Plan.

LINTELS: All Lintels to comply with SANS 10400-K:2011.-Precast prestressed concrete lintels, which comply with the relevant requirements ofSANS 1504, may bebuilt into walls compositely with masonry in accordance with table 27 and figure 30.-Secondary reinforcement in accordance with table 23 shall be provided in theuppermost bed joint.-Where the width of piers between adjacent openings is less than 750 mm, theprimary reinforcement, as given in table 28 shall be provided at the top of the linteland extend across at least half of the length of the openings on either side of the pier.-Lintels shall be set in mortar and have a minimum bearing ofa) lintel that supports masonry only: 150 mmb) lintel that supports roof trusses of1) span less than or equal to 1,5 m: 150 mm2) span between 1,5 m and 2,5 m: 250 mm3) span greater than or equal to 2,5 m: 350 mm-All openings with clear span bigger than 3.5m to receive a reinforced concretebeam as per Engineers details and specifications.

FLOOR CONSTRUCTION 1: GROUND FLOOR:Finish: Floor finish as shown, on 25mm screed on 100mm30MPa concrete slab to engineers details and specificationson Isoboard® insulation (elsewhere specified) on Gundle®API USB Green 170Hm damp proof membrane underconcrete surface beds conforming to SANS 952-1:2011 laidwith minimum 150mm overlaps and sealed with Gunplaspressure sensitive tape on 50mm sandbed on min. 150mmwell compacted filling. All compacted earth fill to becompacted to 98% mod AASHTO and not to exceed layerthickness of 150 mm. Provide 193 mesh where fillingexceeds more than 900mm. All floors to stoeps and patios tohave efficient fall away from building. All floors to stoeps andpatios to have efficient fall away from building. All externaltiles to be non-slip tiles.Skirting: As per GENERAL NOTES.

FOUNDATION WALL CONSTRUCTION:R.O.K Bricks Cavity: 50mm The inner and outer cavity wallsto be tied with pvs butterfly wall ties; 5 per sqm. Cavity to befilled with concrete from foundations up to ground floor dpm.All Walls to comply with SANS 10400-K:2011.

FOUNDATION CONSTRUCTION:Foundations are to be casted in sizes as per engineersdetails and specifications, consisting of 1 part Portlandcement, 4 parts clean sand and 6 parts 19mm coarseaggregate.All Foundations to comply with SANS 10400-H:2011.

GENERAL NOTES:FASCIAS, BARGE BOARDS, GUTTERS and DOWNPIPES:ROOF CONSTRUCTION 1: MAIN ROOF: 45° RoofpitchGUTTERS & DOWNPIPES: Watertite Guttering domestic Ogee profile aluminiumH3003h 14 seamless gutter, overall size 125x85x0,6mm thick coated internally andexternally with ColourTech G4 in colour Armour Grey including cut and mitred anglescovered with a mitre strip externally, stop ends crimped and all sealed on the insidewith Dow Corning 813 silicone sealer, secured to fibre cement fascia with 20x2,5mminternal hanger brackets @ 600mm centres using aluminium peeled rivets, with100x75mmØ corrugated downpipe complying with SABS 11, fixed to wall withholderbats, with downpipes riveted and silicone sealed to gutter outlets, including allnecessary bends, elbows, shoes etc. Downpipes painted to match colour of windows(armour grey).FASCIAS: Everite medium density plain ungrooved Nutec fascia boards, size220x15mm fixed to timber beam twice screwed with 12x40mm countersunk brassscrews with PVC H-profile fascia joiner between boards and at board ends, all inaccordance with the manufacturer's recommendations.

ROOF CONSTRUCTION 2: COVERED BRAAI STOEP: 3° RoofpitchGUTTERS & DOWNPIPES: Watertite Guttering domestic Ogee profile aluminiumH3003h 14 seamless gutter, overall size 125x85x0,6mm thick coated internally andexternally with ColourTech G4 in colour Armour Grey including cut and mitred anglescovered with a mitre strip externally, stop ends crimped and all sealed on the insidewith Dow Corning 813 silicone sealer, secured to fibre cement fascia with 20x2,5mminternal hanger brackets @ 600mm centres using aluminium peeled rivets, with100x75mmØ corrugated downpipe complying with SABS 11, fixed to wall withholderbats, with downpipes riveted and silicone sealed to gutter outlets, including allnecessary bends, elbows, shoes etc. Downpipes painted to match colour of windows(armour grey).FASCIAS: Everite medium density plain ungrooved Nutec fascia boards, size220x15mm fixed to timber beam twice screwed with 12x40mm countersunk brassscrews with PVC H-profile fascia joiner between boards and at board ends, all inaccordance with the manufacturer's recommendations.

ROOF CONSTRUCTION 3: CONCRETE ROOF:DOWNPIPES & OUTLETS:3 x Saint-Gobain 45° side roof outlet eared with dome grate.3 x 100mmØ pvc downpipes built into walls complying with SABS 11, fixed to wall withholderbats, with downpipes riveted and silicone sealed to fullbore outlets, including allnecessary bends, elbows, shoes etc.

TIMBER FINISHES:INTERIOR TIMBER DOORS and SKIRTINGS: Dulux Wash 'n Wear Matt adhesionpromoted pure acrylic paint to all interior timber. Sand with abrasive paper, leavingsurface clean and dust free. Prime surface with one coat Dulux Supergrip with anovercoating time of 12 hours and finish with two coats Dulux Wash 'n Wear Matt withan overcoating time of 4 hours.INTERIOR AND EXTERIOR WOOD: Woodgard Interior/Exterior Timbavarnish alkydevarnish to all interior and exterior wood. Sand with abrasive paper, leaving surfaceclean and dust free. Apply two coats Woodgard Interior/Exterior Timbavarnish with anovercoating time of 4 hours.

Internal Plaster: 10-15mm single coat of internal plaster shall be steel trowelled to asmooth, even and true finish.External Plaster: 10-15mm single coat shall be finished to a true and even surfacewith a wood float.All plaster surfaces shall be free from blemishes, cracks, blisters or other defects.Plaster shall turn into reveals and soffits of openings, and all angles shall be true andstraight with salient angles slightly rounded.

WALL FINISHES:INTERIOR: Smooth plastered and painted. Dulux Wash 'n Wear Matt adhesionpromoted pure acrylic paint to interior cement plaster or gypsum plaster. Surface tobe clean, dry and dust free with a moisture content of less than 15%. Prime surfacewith one coat Dulux Primer for New Plaster (Code: D192-0802) with an overcoatingtime of 18 hours and finish with two coats Dulux Wash 'n Wear Matt (Code: D170-0734) with an overcoating time of 4 hours. (Paint colours as per estate guidelines)EXTERIOR: Smooth plastered and painted. Dulux Weatherguard Ultrasmoothadhesion promoted pure acrylic paint to all exterior cement plaster. Surface to beclean, dry and dust free with a moisture content of less than 15%. Apply one coatDurafill Fillercoat (Code: M370-2700) with an overcoating time of 4 hours and finishwith two coats Dulux Weatherguard Ultrasmooth (Code: D186-LINE) with anovercoating time of 4 hours. (Paint colours as per estate guidelines)

WALL TILES: Kitchen and Scullery: Wall tiles laid above cabinets and counters tounderside of wall mounted cupboards.Ensuites & Bathrooms: Wall tiles laid from Floor to Ceiling height. Wall Tiles as perclients specifications.

FLOOR FINISH: all external tiles at COVERED STOEP & COVERED STOEP withBRAAI, must be NON-SLIP.

CORNICES AND SKIRTINGS:Cornice: Creative cornicing, polystirene cornice cataloque number: CC013. to bepainted as per clients specifications.Skirtings: Pedross Skirtings, code: MFS 120, 120x18mm high skirting board to beinstalled as per manufacturers recommendations. Skirting to be painted as per clientsspecifications.

PAVERS & PAVING:Smartstone Ibanzi Pavers 1000x500mm, 40mm thick, laid loose on ground towardscovered entrance.Smartstone Square Pavers 500x500mm, 40mm thick, laid loose on ground arounddwelling in garden.DRIVE WAY: Smartsone Aztech Cobble paving, colour: Charcoal, size:148x148x50mm covering 150x150mm. To be used in driveway & drying yard.

G R O U N D S T O R E Y P L A NSCALE 1:100

R O O F / S I T E P L A NSCALE 1:100

Page 5: UITGEZOCHT DESIGN PROPOSAL ERF 54 ıuitgezochtestate.com/images/documents/54-plans.pdf · SANS 10142-1. - Plumbing installation to comply with local authority requirements and SANS

294 MAIN ROAD ı PAARLP.O. BOX 7158 ı 7646

t: 021 872 4536 ı m: 082 771 5902 ı e: [email protected]

PrArch • SACAP reg. no. 7685

DRAWING NO. 54UIT-C003

SKETCH COUNCIL CONSTRUCTION

SCALE:

●●

PROJECT REF. 62-54UIT- 54 UITGEZOCHT

DRAWN: CHECKED:A. J v VUURENCANT 21888

A. MARAISPR.ARCH 7685

AS SHOWN DATE: 27.06.2016

PROJECT:PROPOSED NEW DWELLINGFarm 811 portion 54CLIENT:UITGEZOCHT ESTATE PTY. LTD.

NOTES

NOTES

- THE DESIGN ON THIS DRAWING IS COPYRIGHT AND REMAINS THE PROPERTY OF ABRÉ MARAIS ARCHITECTS.- ALL WORK IS TO BE CARRIED OUT IN ACCORDANCE WITH THE N.B.R SANS 10400 AND LOCAL AUTHORITY REGULATIONS.- CONTRACTOR, SUB-CONTRACTORS & SPECIALIST SUB-CONTRACTORS TO CHECK ALL DIMENSIONS AND LEVELS ON SITE PRIOR TO ANY CONSTRUCTION.- ANY DISCREPANCIES TO BE IMMEDIATELY REPORTED TO THE ARCHITECT FOR CLARIFICATION.- USE FIGURED DIMENSIONS, DO NOT SCALE.- SETTING OUT TO BE DONE FROM THE SURVEYOR'S PEGS.- CONTRACTOR, SUB-CONTRACTORS & SPECIALIST SUB-CONTRACTORS TO ENSURE WORKS TENDERED UPON COMPLY WITH ALL RELEVANT SAFETY AND/OR HEALTH STANDARDS. ANY DEVIATIONS REQUIRED TO ARCHITECTS DESIGN AND DETAIL DRAWINGS TO ENSURE LEGAL/SAFETY COPLIANCE ARE TO BE QUALIFIED AT TENDER STAGE.

ENERGY SAVING NOTES

- Geyser to be coupled to solar panels, to be wrapped with Isover non- combustable geyser insulation. Insulate hotwater piping where not built into wall, insulate all exposed hotwater pipes with Isover to a minimum R-value of 1.00.- Water saving - water saving or low flow shower heads, dual flush toilets, tap aerators. Energy saving bulbs to be used in house.- Isotherm to be provided to specialist contractor as per SANS 10400-XA.- All roofs to be insulated so that a min. R-value of 3.7 is achieved (to comply with SANS 10400-XA:2011: 4.4.5.1.). Type of insulation to be flexible polyester blanket (Isotherm or similar approved) with a density of 11.5kg/m³ installed as per SANS 204:2011 thickness min. 160mm and R- value of a min. 3.3 (for main roof) and min. 3.35 (for lean-to roofs).- Electrical installation to comply with local authority requirements and SANS 10142-1.- Plumbing installation to comply with local authority requirements and SANS 10400.- Natural ventilation to comply with municipal regulations and SABS0400 in terms of min. 5% floor area.- Natural light to comply with municipal regulations and SABS 0400 in terms of min. 10% floor area.

FW

MD

W

RG

1.2

1.2

H

100x75mmr.d.p with CP.

100x75mmr.d.p with CP.

100x75mmr.d.p with CP.

100x75mmr.d.p with CP.

100mmØ r.d.pwith CP.

100mmØ r.d.pwith CP.

100mmØ r.d.pwith CP.

100x75mmr.d.p with CP.

GG

G tap

tap

CP with grid

110m

SW

P

110mmØ SWP

110mmØ SWP

110m

SW

P

110mmØ sewerage line

110mmØ sewerage line

RE1IE1

IE.5:cl :142.100il :141.650d :450mm

IE.2 to IE.3:9 620mm @ 10.2

940mm

IE.5 to IE.4:12 700mm @ 16.7

760mm

IE.3:cl :141.775il :140.115d :1 660mm

IE.3 to MH.1:7 280mm @ 16.7

435mm

IE.1 to IE.2:5 600mm @ 10.4

540mm

MH.1:cl :140.600il :139.600d :1000mm

IE.2:cl :141.870il :141.055d :815mm

IE5

IE.1:cl :142.045il :141.595d :450mm

connect to existing sewer system

1200

1200

1200

1200

700

1500

1500

300

300

300 300

300

300

300

300

300

300 300

300

1500 1500

1200

ceilingtrap

ceilingtrap

M

water meter to connectto existing municipalwater connection

NOTE: 1 x 150 Litre slimline 600i Dual geyser &1 x 100 Litre slimline 600i Dual geyser,coupled wih Kwiksol Indirect System installedas a split system.

150

Litre

100

Litre

Kwiksol Indirect Systeminstalled on concrete roof

IE.4:cl :141.775il :140.890d :885mm

110m

sew

erag

e lin

e

IE3IE2

IE4

pavement laid to fall toCP with grid.

CP with grid

pavement laid to fallto CP with grid.

IE.3

to IE

.4:

12 9

45m

m @

16.

777

5mm

MH.1

existing 2m servitude line110mmØ SWP to be laid through

ERF 51 in 2m servitute line, to connectwith existing stormwater channels.

RE2RE3

2

2

1 G

2

2

2

2

2

2

2

2

2

2 2

2

2

2

2

2

2 2

2

2 2

2DB

EWH

EWH

T

TSP

NOTE: SOLAR PANNELS to be hidden fromstreet views.HEAT PUMPS & AIRCON units to be hidden bywhite nutec board cladding where visible tosurrounding erven or street views.

Full Element ID V01 W01 W02 W03 W04

View fromOpening Side

300

1 20

0

300

1 20

0

1 500

1 80

0

750

1 50

0

750

900

600

1 20

0

Home Story: First Storey First Storey Ground Storey Ground Storey Ground Storey Ground StoreyHead Height: 1 650 1 800 2 100 2 100 2 100 2 100Sill Height: 450 600 300 600 1 200 900Glazing Area 0,00 0,00 2,16 0,85 0,50 0,51ORIENTATION: 1 x WEST, 1 x EAST 1 x WEST, 1 x EAST 1xNORTH, 1xEASTH, 1xWEST 3 x NORTH 1 x NORTH, 1 SOUTH 1 x SOUTH

DESCRIPTION: Aluminium Louvre Vent. Aluminium Louvre Vent.

Purpose made aluminium doublewindow frame with transom sash &lower sash with divisions, 2 tophungs both sides with fixed glasspanels on main sashes.

Purpose made aluminiumwindow frame with transomsash & lower sash, 2 top hungswith fixed glass panel on lowersash.

Purpose made aluminium windowframe with lower sash, top hungwith fixed glass panel on lowersash.

Purpose made aluminium windowframe with transom sash, 2 tophung openings.

FINISH:Powder Coated Aluminium.Armour grey, to match roofcolour.

Powder Coated Aluminium.Armour grey, to match roofcolour.

Powder Coated Aluminium. Armourgrey, to match roof colour.

Powder Coated Aluminium.Armour grey, to match roofcolour.

Powder Coated Aluminium. Armourgrey, to match roof colour.

Powder Coated Aluminium. Armourgrey, to match roof colour.

GLAZING: - -

WINDOW GLAZING TO COMPLYWITH SANS 10400 PART N,SAGGA & AAAMSA, as perFenestration calculations.

WINDOW GLAZING TOCOMPLY WITH SANS 10400PART N, SAGGA & AAAMSAas per Fenestrationcalculations.

WINDOW GLAZING TO COMPLYWITH SANS 10400 PART N,SAGGA & AAAMSA as perFenestration calculations.

WINDOW GLAZING TO COMPLYWITH SANS 10400 PART N,SAGGA & AAAMSA as perFenestration calculations.

SILL:

EXTERNAL: 45° brick sill,plastered flush with wall.Plastered and painted asper Uitgezocht guidelines.INTERNAL: Plastered andpaintedas per client.

EXTERNAL: 45° brick sill,plastered flush with wall.Plastered and painted asper Uitgezocht guidelines.INTERNAL: Plastered andpaintedas per client.

EXTERNAL: 45° brick sill, plasteredflush with wall. Plastered andpainted as per Uitgezochtguidelines.INTERNAL: Plastered andpaintedas per client.

EXTERNAL: 45° brick sill,plastered flush with wall.Plastered and painted as perUitgezocht guidelines.INTERNAL: Plastered andpaintedas per client.

EXTERNAL: 45° brick sill, plasteredflush with wall. Plastered andpainted as per Uitgezochtguidelines.INTERNAL: Plastered andpaintedas per client.

EXTERNAL: 45° brick sill, plasteredflush with wall. Plastered andpainted as per Uitgezochtguidelines.INTERNAL: Plastered andpaintedas per client.

OTHER:

ALL VENTS to bepositioned acc. Toelevation dimensionsabove wallplate height ingable wall. Vent sizes accTO SUPPLIER.

ALL VENTS to bepositioned acc. Toelevation dimensionsabove wallplate height ingable wall. Vent sizes accTO SUPPLIER.

Window sizes acc TO SUPPLIER.Measurements to be made on site.

Window sizes acc TOSUPPLIER. Measurements tobe made on site.

Window sizes acc TO SUPPLIER.Measurements to be made on site.

Window sizes acc TO SUPPLIER.Measurements to be made on site.

GENERAL:

Insect gauge installed ininterior side of vent.Supplied and installed allin accordance with themanufacturer'srecommendations.

Insect gauge installed ininterior side of vent.Supplied and installed allin accordance with themanufacturer'srecommendations.

WINDOW and IRONMONGERY:Supplied and installed all inaccordance with the manufacturer'srecommendations.

WINDOW andIRONMONGERY: Suppliedand installed all in accordancewith the manufacturer'srecommendations.

WINDOW and IRONMONGERY:Supplied and installed all inaccordance with the manufacturer'srecommendations.

WINDOW and IRONMONGERY:Supplied and installed all inaccordance with the manufacturer'srecommendations.

Full Element ID D01 D02 D03 D04 D05 D06 G01

View from SideOpposite toOpening Side

1 500

2 10

0

925

2 10

0

925

2 10

0

3 600

2 10

0

900

2 10

0

4 880

2 23

0

985

1 80

0

Height 2 100 2 100 2 100 2 100 2 100 2 180 1 800GLAZING AREA: 1,85 0,00 0,00 5,37 0,00 0,00 0,00

Home Story Ground Storey Ground Storey Ground Storey Ground Storey Ground Storey Ground Storey Ground Storey

ORIENTATION: 1 x WEST 5 x Interior 1 x Interior 1 x EAST 1 x SOUTH 1 x exterior 1 x exterior

DESCRIPTIONFRAME:

Purpose made Aluminium door framewith side light, size as shown.

Swartland side hung timber door framesize as shown.

Swartland side hung timber door framesize as shown. Door to be fire ratedwith half an hour fire rating.

Purpose made aluminium fold-a-side stacking door 4 leaf configurationframe.

Purpose made Aluminium door framewith side light, size as shown.

Door hung on galvanised door gear comprising tracks, torsion bar and balance springs, hinge rollers,buffers, etc, with the vertical tracks fixed to concrete or brickwork and overhead track hung belowbrickwork soffit.

Frame to be 2 x 50x50mm steel posts(powder coated) fixed to walls.

DESCRIPTIONLEAF:

Purpose made Aluminium side hungdoor with fixed side light. Fixed glassfor both panels of door.

Swartland Cape Culture MDFHorizontal, Code: MDFHRZHIO,interior medium density fibre, heavyduty, size 813x2032mm(h), 44mmthick, interior door.

Swartland Cape Culture MDFHorizontal, Code: MDFHRZHIO,interior medium density fibre, heavyduty, size 813x2032mm(h), 44mmthick, interior door.

Purpose made aluminium fold-a-side stacking door 4 leaf configuration. 4doors stacking right. Size as shown and indicated on plan. All door paneswith 2 fixed glass pannels with devider.

Purpose made Aluminium side hungdoor with fixed side light. Fixed glassfor both panels of door.

Coroma Coroflute Aluminium 5 panel single (fluted) sectional electrically operated garage door tosuit opening size 2440 x 2180mm high with 220mm wide nibs to both sides of opening with 3400mmclear backspace behind door and 2535mm floor to ceiling.

Purpose made Swartland timber gate.Bilau timber horizontal slats spacedevenly with 20mm gaps.

FINISH: Powder coated aluminium frame,Armour grey, to match roof colour.

Sand down timber surface to a finesmooth finish and apply three coatsSwartland Maxicare qualitytimbersealant prior to installation, all inaccordance with the manufacturer'srecommendations. Painted.

Sand down timber surface to a finesmooth finish and apply three coatsSwartland Maxicare qualitytimbersealant prior to installation, all inaccordance with the manufacturer'srecommendations. Painted.

Powder coated aluminium frame, Armour grey, to match roof colour. Powder coated aluminium frame,Armour grey, to match roof colour. Powder Coated Aluminium. Armour grey, colour to match Roof and frames of windows and doors.

Sand down timber surface to a finesmooth finish and apply three coatsSwartland Maxicare qualitytimbersealant prior to installation, all inaccordance with the manufacturer'srecommendations. Painted.

GLAZING:ALL GLAZING TO COMPLY WITHSANS 10400 PART N, SAGGA &AAAMSA, as per FenestrationCalculations.

- - ALL GLAZING TO COMPLY WITH SANS 10400 PART N, SAGGA &AAAMSA, as per Fenestration Calculations.

ALL GLAZING TO COMPLY WITHSANS 10400 PART N, SAGGA &AAAMSA, as per FenestrationCalculations.

- -

GENERAL:Locksets & hinges to be specified andinstalled according to Manufacturersspecifications and recommendations.

Locksets & hinges to be specified andinstalled according to Manufacturersspecifications and recommendations.

Locksets & hinges to be specified andinstalled according to Manufacturersspecifications and recommendations.

Locksets & hinges to be specified and installed according to Manufacturersspecifications and recommendations.

Locksets & hinges to be specified andinstalled according to Manufacturersspecifications and recommendations.

Frame, Door & Ironmongery to be installed and supplied all in accordance with manufacturer'srecommendations.

Locksets & hinges to be specified andinstalled according to Manufacturersspecifications and recommendations.

OTHER:ALL DOORS TO BE IN LINE WITHLINTOL HEIGHT AS INDICATED, doorsizes acc TO SUPPLIER.

ALL DOORS TO BE IN LINE WITHLINTOL HEIGHT AS INDICATED , doorsizes acc TO SUPPLIER. TIMBERhorizontal slatted DOOR.

ALL DOORS TO BE IN LINE WITHLINTOL HEIGHT AS INDICATED , doorsizes acc TO SUPPLIER. TIMBERhorizontal slatted DOOR.

ALL DOORS TO BE IN LINE WITH LINTOL HEIGHT AS INDICATED, doorsizes acc TO SUPPLIER.

ALL DOORS TO BE IN LINE WITHLINTOL HEIGHT AS INDICATED ,door sizes acc TO SUPPLIER.

- -

300m

m

2D

300 0.9

1.2

V

H

M

1200

Tc

1

1 G

2

ELECTRICAL LEGEND

Light switch with dimmer

Electrical connection cable

FFL

Telephone connection

Wall mounted speakers / sound system

Ceiling mounted fan

CL

Light switch

Light switch - two way

Solar pannel.

40mm Speaker / sound system connection conduit

ELECTRICALEQUIPMENT

Surface mounted light fitting

Down light

Foot light / recessed brick light fitting at 300mm above FFL

0.9m Fluorescent tubes

Interior wall mounted light fitting

LIGHT FITTINGS

Recessed distribution board

Single 3p wall socket

Double 3p wall socket

Hight in mm above FFL

Hight in mm above FFL

TV antenna / dish socket connection

40mm Empty conduit with draw wire

LED Rope light (in bulkhead detail)

Electrical Water Heater.

Extraction fan activated by light switch

Surface mounted pendant luminaire

DB

1.2m Fluorescent tubes

Down light - vapour proof

Exterior wall mounted light fitting

Recessed waterproof ground light - outdoor

Submersible pool light (by specialist)

Garden spike light

SYMBOL DESCRIPTION SYMBOL DESCRIPTION

Exterior wall mounted light fitting - heat resistant

Socket in soffit for garage door automation

Motion sensor

Star light

EWH

SP

C

H

T

PV

WATER METERM

15cw

RED HW 15/22 BENEATHGROUND AND FLOOR LEVEL

BLUE CW 15EXTERNAL/INTERNAL

LEG

END

WAT

ER R

ETIC

ULA

TIO

N

15/22hw

COPPER PIPEOUTSIDE, INSIDEAND BENEATHGROUND

MIXER (TWO MANUALCONTROLS)

SHOWER

STOP VALVE

FLOAT VALVE

TAP (EXTERNAL)

TAP (INTERNAL)

NON-RETURN VALVE

TEMPERATURE ANDPRESSURE SAFETY VALVE(SAFETY VALVE)

VACUUM RELIEF VALVE

RISER PIPE (PLAN VALVE)

DROPPER PIPE (PLAN VIEW)

HEAT PUMP

PRESSURE RELIEF VALVE

NOTES:STORMWATER:All Stormwater Disposal to comply withSANS 10400-R:2011.All downpipes to dispose into catchpits and into mainstormwater system as indicated on the drawings.All stormwater disposal as per specialist, supplied andinstalled all in accordance with the manufacturer'srecommendations.

DRAINAGE:All Drainage to comply with SANS 10400-P:2011.Soil and vent pipes and fittings to be Marley uPVC(SABS 967) of 75mm or 110mm diameter as indicated onthe drawings.Waste pipes and fittings to be Marley uPVC (SABS 967)of 40mm or 50mm diameter as indicated on the drawings.All exposed fittings to be access fittings.All sanitary ware on First Floor to be fitted with deepseal traps.All drainage as per specialist, supplied and installed all inaccordance with the manufacturer's recommendations.

HEADWALL FLASHING 305 GIRTHnot to scale

SIDEWALL FLASHING 305 GIRTHnot to scale

DOOR AND WINDOW NOTE:

THE CONTRACTOR MUST CHECK ALL MEASUREMENTS AND LEVELS ON SITE AND ANY DISCREPENCIES MUSTBE REPORTED IMMEDIATLY TO THE DESIGNER BEFORE MANUFACTURING AND INSTALLATION PROCEEDS.

GLAZED IN ACCORDANCE WITH SANS 10160:2010, SANS 10137:2002, SANS 10400:2010 (Part N of Section 3) ANDSANS 1263-1:2006 AND AAAMSA SELECTION GUIDE FOR SAFETY GLAZING MATERIALS. NAME OFMANUFACTURER PERMANENTLY MARKED ON EACH PANE VISIBLE AFTER GLAZING, IN ACCORDANCE WITHNBR PART N SCHEDULE 1 AND SANS 10137:2002.

SAFETY GLAZING AS PER SAFETY GLAZING REQUIREMENTS.ALL ALUMINIUM WINDOW CASEMENT TO BE 38mm FRAMES.

ALL ALUMINIUM WINDOWS AND EXTERNAL ALUMINIUM DOORS PROFILES AND INSTALLATION MUST BECOMPLYING WITH AAAMSA PERFORMANCE CRITERIA IN ACCORDANCE WITH SANS 613.

ALL ALUMINIUM WINDOWS AND EXTERNAL ALUMINIUM DOORS TO BE POWDER COATED AND PAINTEDARMOUR GREY TO MATCH ROOF COLOUR, GLAZINGSHALL BE EXECUTED STRICTLY IN CONFORMANCE WITH GLASS MANUFACTURER'S RECOMMENDATIONS ANDALL IN ACCORDANCE WITH THE NATIONAL BUILDING REGULATIONS PARTS B, N, T, SANS 10137, SANS 10400AND SANS 1263, FITTED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.

FIT 30x30mm ALUM. ANGLE FIXED UNDER FRAME OF ALL EXTERNAL DOOR FRAMES. TO BE WATERPROOFEDBY SPECIALIST.FIT CABIN HOOKS TO ALL EXTERNAL SIDE HUNG DOORS.FIT DOOR STOPS TO ALL NECESSARY DOORS.

ALL WINDOWS AND EXTERNAL DOORS AS VIEWED FROM OUTSIDE. THE CONTRACTOR MUST CHECK ALLINTERNAL DOORS OPENING DIRECTIONS TO BE AS PER FLOORPLANS.FLOOR FINISH TO BE ADJACENT TO BOTTOM FRAME OF ALL WINDOW SILLS WITH 0mm SILL HEIGHT FROMFFL.ALL SHOWER DOORS TO BE PURPOSE MADE FRAMELESS SHOWER CUBICLES AS PER "SHOWER CONCEPTS"OR SIMILAR APPROVED TO MANUFACTURERS SPECIFICATIONS.

HEADWALL FLASHING 305 GIRTH

COUNTER FLASHINGbuilt into wall

TOE CLOSURE

ROOF SHEETSIDEWALL FLASHING 305 GIRTH

COUNTER FLASHINGbuilt into wall

ROOF SHEET

COUNTER FLASHINGbuilt into wall

E L E C T R I C A L / S T O R M W A T E R / S E W E R A G E - L A Y O U TSCALE 1:100

W I N D O W S C H E D U L ESCALE 1:50

D O O R S C H E D U L ESCALE 1:50