    L2 Plumbing Unit 6 Apply domestic cold-water system installation and maintenance techniques

    Unit 6: Activity Sheet 6.6

    Learner: Date:

    Maintenance and decommissioning

    Aims and objectives

    At the end of activities 6.6A and 6.6B, learners should be able to:

    describe the maintenance requirements for a:

    1 stop tap

    2 hot- and cold-water tap

    3 float-operated valve

    4 shower mixer valve describe the procedures for decommissioning hot- and cold-water systems.

    Pearson Education Ltd 2011. Copying permitted for purchasing institution only. This material is not copyright free.1

  • 7/29/2019 v031176_u6_asl6.6

    2/5

    L2 Plumbing Unit 6 Apply domestic cold-water system installation and maintenance techniques

    Unit 6: Activity Sheet 6.6

    Learner: Date:

    Activity 6.6A Maintenance and decommissioning

    Answer the following questions.

    1 The principles of maintenance and servicing are quite simple. What are the sixthings you need to know?

    2 What are the common faults on the following taps and valves? How or where doyou isolate the faults?

    a Stop taps

    Common faults include:

    Isolate:

    Pearson Education Ltd 2011. Copying permitted for purchasing institution only. This material is not copyright free.2

  • 7/29/2019 v031176_u6_asl6.6

    3/5

    L2 Plumbing Unit 6 Apply domestic cold-water system installation and maintenance techniques

    Learner: Date:

    b Hot- and cold-water taps

    Common faults include:

    Isolate:

    c Float-operated valves:

    Common faults include:

    Isolate:

    d Shower mixer valves:

    Common faults include:

    Isolate:

    Pearson Education Ltd 2011. Copying permitted for purchasing institution only. This material is not copyright free.3

  • 7/29/2019 v031176_u6_asl6.6

    4/5

    L2 Plumbing Unit 6 Apply domestic cold-water system installation and maintenance techniques

    Learner: Date:

    3 What are the common faults on a full-way gate valve?

    4 What does decommissioning mean?

    5 Explain what the water regulations require you to do to dead legs whenpermanently decommissioning.

    Pearson Education Ltd 2011. Copying permitted for purchasing institution only. This material is not copyright free.4

  • 7/29/2019 v031176_u6_asl6.6

    5/5

    L2 Plumbing Unit 6 Apply domestic cold-water system installation and maintenance techniques

    Learner: Date:

    Activity 6.6B Maintenance and decommissioning

    Answer the questions below.

    1 Imagine you have decommissioned an indirect cold-water system in an olddomestic property, in preparation for demolition. The indirect system fed a bath,washbasin and WC; the rising main fed the sink and CWSC.

    Write a short report on how you did the job, including how you liaised with othersite workers.

    2 How would you remove a circlip from a spindle?

    a Use a chisel to prize it off.

    b Use a small screwdriver to push it out.

    c Use circlip pliers to open and pull off.

    d Taps do not have circlips they have SOM clips.

    3 If you have a water hammer problem how can this be solved?

    a Replace float valve with equilibrium valve.

    b Replace float valve with Portsmouth pattern valve.

    c Increase pressure to system by opening stop-tap so it is fully open.

    d Remove float from arm of float valve.

    Note: point d would stop the water hammer but it would cause massive floodingof the house so not a recommended option!)

    General point

    Discuss the report with your tutor and your classmates.

    Pearson Education Ltd 2011. Copying permitted for purchasing institution only. This material is not copyright free.5