vilas 215 - ptn dien - co dien viet nga - ba ria vung tau
DESCRIPTION
Viet NgaTRANSCRIPT
-
PH LC ATTACHMENT
(Km theo quyt nh s: 119.2012 / Q - VPCNCL ngy 14 thng 5 nm 2012 ca gim c Vn phng Cng nhn Cht lng)
AFL 01.09 Ln ban hnh: 5.10 Trang: 1/21
Tn phng th nghim: Phng th nghim k thut in
Laboratory: Electrotechnic Laboratory
C quan ch qun: X nghip C in Lin doanh Vit - Nga - VIETSOVPETRO
Organization: Mecanical and Energetic Divison VIETSOVPETRO
Lnh vc th nghim: in in t
Field of testing Electrical - Electronics
Ngi ph trch/ Representative: L Minh Trng
Ngi c thm quyn k/ Approved signatory: 1. L Minh Trng Tt c cc php th c cng nhn/ All accredited tests
2. ng Trng Phng Tt c cc php th c cng nhn/ All accredited tests
S hiu/ Code: VILAS 215
a ch/ Address: 13 L Quang nh, Phng Thng Nht, TP Vng Tu, B Ra - Vng Tu
a im/Location: 13 L Quang nh, Phng Thng Nht, TP Vng Tu, B Ra - Vng Tu
in thoi/ Tel: 064 3839871 - 3464 Fax: 064 3616755
E-mail: [email protected] Website: www.vietsov.com.vn
-
DANH MC PHP TH C CNG NHN LIST OF ACCREDITED TESTS
VILAS 215
AFL 01.09 Ln ban hnh: 5.10 Trang: 2/21
Lnh vc th nghim: in in t Field of Testing: Electrical - Electronic
TT
Tn sn phm, vt liu c th
Materials or products tested
Tn phng php th c th The name of specific tests
Gii hn pht hin (nuc)/Phm vi o Detection limit (if
any)/range of measurement
Phng php th Test methods
1.
My bin p in lc (cp in p ti 35kV)
Power transformer (voltage up to 35kV)
Kim tra nhm u dy
Check DYN of transformers
- phn gii resolution: 0,1mV
- Phm vi o / Range of measurement: 1mV 1000 Vac
TCVN 6306-1: 2006
IEC 60076-1: 2000
2. o t s bin in p
Measure ratio of transformers
- phn gii / Resolution: 0,0001
- Phm vi o / Range of measurement:
Autoranging; 0,80001500,0:1
TCVN 6306-1: 2006
IEC 60076-1: 2000
3.
o in tr ca cc cun dy bng dng in mt chiu.
Measure winding resistance of transformers by DC current
- Gii hn pht hin/ Detection limit: 1
- Phm vi o / Range of measurement: 10-5 106
TCVN 6306-1: 2006
IEC 60076-1: 2000
4. o tn hao dng khng ti
Measure loss with unload current
- phn gii / Resolution:
0,1V; 0,1A; 1,0 W(VA) - Phm vi o / Range of measurement:
1V 600V rms (AC+DC)
1A 1000A rms (AC+DC)
1W (VA) 600 kW (kVA) average
TCVN 6306-1: 2006
IEC 60076-1: 2000
-
DANH MC PHP TH C CNG NHN LIST OF ACCREDITED TESTS
VILAS 215
AFL 01.09 Ln ban hnh: 5.10 Trang: 3/21
TT
Tn sn phm, vt liu c th
Materials or products tested
Tn phng php th c th The name of specific tests
Gii hn pht hin (nuc)/Phm vi o Detection limit (if
any)/range of measurement
Phng php th Test methods
5.
My bin p in lc (cp in p ti 35kV)
Power transformer (voltage up to 35kV)
Th c cu iu chnh in p
Test the voltage adjusting mechanism
- phn gii / Resolution:
0,1 mV
- Phm vi o / Range of measurement:
1mV 1000 Vac
TCVN 6306-1: 2006
IEC 60076-1: 2000
6.
o thng s in mi ca cch in
Measuring dielectric parameter of insulation
- phn gii / Resolution:
10 k; 0,01 nA
- Phm vi o / Range of measurement:
100 k 5 T; 0,1 nA999 A
TCVN 6306-3: 2006
IEC 60076-3: 2000
7.
Th nghim bn in ca cch in bng in p xoay chiu tn s cng nghip
Test electric strength of insulation by A.C voltages at industrial frequency
- phn gii / Resolution:
0,1 kV; 0,1 mA
- Phm vi o / Range of measurement:
0,5 125kV; 1 mA 100 mA
TCVN 6306-3: 2006
IEC 60076-3: 2000
8.
o tn hao v in p ngn mch
Measuring losses and short-circuit voltage
- phn gii / Resolution:
0,1V; 0,1A; 1,0 W (VA) - Phm vi o / Range of measurement:
1V 600V rms (AC+DC)
1A 1000A rms (AC+DC)
1W (VA) 600 kW (kVA) average
TCVN 6306-5: 2006
IEC 60076-5: 2006
-
DANH MC PHP TH C CNG NHN LIST OF ACCREDITED TESTS
VILAS 215
AFL 01.09 Ln ban hnh: 5.10 Trang: 4/21
TT
Tn sn phm, vt liu c th
Materials or products tested
Tn phng php th c th The name of specific tests
Gii hn pht hin (nuc)/Phm vi o Detection limit (if
any)/range of measurement
Phng php th Test methods
9.
My bin p o lng Voltage transformer
o t s bin in p v sai lch pha
Measure ratio of transformers and incorrect phases
- phn gii / Resolution:
0,0001
- Phm vi o / Range of measurement:
Autoranging; 0,80001500,0:1
TCVN 7697-2: 2007
IEC 60044-2: 2003
10.
Th nghim in p tn s cng nghip trn cun s cp, gia cc phn v trn cun th cp
Test electric strength of insulation by A.C voltage at industrial frequency for primary windings, among the part of trasformer and secondary windings
- phn gii / Resolution:
0,1 kV; 0,1 mA
- Phm vi o / Range of measurement:
0,5 125kV; 1 mA 100 mA
TCVN 7697-2: 2007
IEC 60044-2: 2003
11.
My bin dng Current transformer
o t s bin dng in v sai lch pha
Measure ratio of current transformers and incorrect phases
- phn gii / Resolution:
0,0001
- Phm vi o / Range of measurement:
Autoranging; 0,80001500,0:1
TCVN 7697-1: 2007
IEC 60044-1: 2003
12.
Th nghim in p tn s cng nghip trn cun s cp v cun th cp
Test electric strength of insulation by A.C voltage at industrial frequency for primary winding and secondary windings
- phn gii / Resolution:
0,1 kV; 0,1 mA
- Phm vi o / Range of measurement:
0,5 125kV; 1 mA 100 mA
TCVN 7697-1: 2007
IEC 60044-1: 2003
-
DANH MC PHP TH C CNG NHN LIST OF ACCREDITED TESTS
VILAS 215
AFL 01.09 Ln ban hnh: 5.10 Trang: 5/21
TT
Tn sn phm, vt liu c th
Materials or products tested
Tn phng php th c th The name of specific tests
Gii hn pht hin (nuc)/Phm vi o Detection limit (if
any)/range of measurement
Phng php th Test methods
13.
My in quay Rotating electrical
machine
o in tr ca cc cun dy bng dng in mt chiu trng thi ngui thc t.
Measure resistance of windings by DC current at reality cool state
- Gii hn pht hin/ Detection limit:
1
- Phm vi o / Range of measurement:
10-5 106
TCVN 6627-1: 2008
IEC 60034-1: 2004
IEC 60034-1: 2010
14.
o in tr cch in ca cc cun dy i vi v my v gia cc cun dy
Measure insulation resistance by DC voltage between windings and frame, one winding and other windings
- phn gii / Resolution:
10 k; 0,01nA
- Phm vi o / Range of measurement:
100 k 5 T; 0,1nA999 A
TCVN 6627-1: 2008
IEC 60034-1: 2004
IEC 60034-1: 2010
15.
Th bn in ca cch in ca cc cun dy i vi v my v gia cc cun dy vi nhau
Test electric strength of insulation by A.C voltage at industrial frequency between windings and frame, one winding and other windings
- phn gii / Resolution:
0,1 kV; 0,1 mA
- Phm vi o / Range of measurement:
0,5 125kV; 1 mA 100 mA
TCVN 6627-1: 2008
IEC 60034-1: 2004
IEC 60034-1: 2010
16. o rung my in
Measure vibration of machines
- Gii hn pht hin / Detection limit:
0,1 m/s2 Peak
0,1 mm/s RMS
0,001mm P-P
- Phm vi o / Range of measurement:
1 199,9 m/s2 Peak
1 199,9 mm/s RMS
0,01 1,999 mm P-P
TCVN 6627-14: 2008
IEC 60034-14: 2003 (with amendment 1: 2007) IEC 60034-14: 2007
-
DANH MC PHP TH C CNG NHN LIST OF ACCREDITED TESTS
VILAS 215
AFL 01.09 Ln ban hnh: 5.10 Trang: 6/21
TT
Tn sn phm, vt liu c th
Materials or products tested
Tn phng php th c th The name of specific tests
Gii hn pht hin (nuc)/Phm vi o Detection limit (if
any)/range of measurement
Phng php th Test methods
17. My in quay
Rotating electrical machine
o mc n my in
Measure noise of machines
- Gii hn pht hin / Detection limit:
1 dB
- Phm vi o / Range of measurement:
30 dB 130 dB
TCVN 6627-9: 2011
IEC 60034-9: 2007
18.
My in ng b Synchronous
Electrical machine
o in tr cch in ca cc cun dy i vi v my v gia cc cun dy
Measure insulation resistance by DC voltage between windings and frames, one winding and other windings
- phn gii / Resolution:
10 k; 0,01nA
- Phm vi o / Range of measurement:
100 k 5 T; 0,1nA999 A
TCVN 6627-1: 2008
IEC 60034-1: 2004
IEC 60034-1: 2010
19.
o in tr cun dy bng dng mt chiu trng thi ngui
Measure resistance of windings by DC current at reality cool state
- Gii hn pht hin/ Detection limit:
1
- Phm vi o / Range of measurement:
10-5 106
TCVN 6627-1: 2008
IEC 60034-1: 2004
IEC 60034-1: 2010
20.
Th bn in ca cch in ca cun dy i vi v my v gia cc cun dy
Test electric strength of insulation by A.C voltage at industrial frequency between windings and frame, one winding and other windings
- phn gii / Resolution:
0,1 kV; 0,1 mA
- Phm vi o / Range of measurement:
0,5 125kV; 1 mA 100 mA
TCVN 6627-1: 2008
IEC 60034-1: 2004
IEC 60034-1: 2010
-
DANH MC PHP TH C CNG NHN LIST OF ACCREDITED TESTS
VILAS 215
AFL 01.09 Ln ban hnh: 5.10 Trang: 7/21
TT
Tn sn phm, vt liu c th
Materials or products tested
Tn phng php th c th The name of specific tests
Gii hn pht hin (nuc)/Phm vi o Detection limit (if
any)/range of measurement
Phng php th Test methods
21.
My in ng b Synchronous
Electrical machine
Xc c tnh khng ti v tnh i xng ca in p
Determine unload characteristic and symmetry of voltage
- phn gii / Resolution:
0,1V; 0,1A; 1,0W (VA) - Phm vi o / Range of measurement:
1V 600V rms (AC+DC)
1A 1000A rms (AC+DC)
1W (VA) 600 kW (kVA) average
TCVN 6627-1: 2008
IEC 60034-1: 2004
IEC 60034-1: 2010
22.
Th dng in qu ti ngn hn
Test overload current short-term
- phn gii / Resolution:
0,1 A
- Phm vi o / Range of measurement:
1A 3000 A
TCVN 6627-1: 2008
IEC 60034-1: 2004
IEC 60034-1: 2010
23. ng c in khng ng b ba pha cng sut t 100W tr ln
Three phase asynchronous electric
motors from 100W and higher power
o in tr cch in ca cc cun dy vi v my v gia cc cun dy
Measure insulation resistance by DC voltage between windings and frames, one winding and other windings
- phn gii / Resolution:
10 k; 0,01nA
- Phm vi o / Range of measurement:
100 k 5 T; 0,1nA999 A
TCVN 6627-1: 2008
IEC 60034-1: 2004
IEC 60034-1: 2010
24.
o in tr ca cc cun dy bng dng in mt chiu trng thi ngui
Measure resistance of windings by DC current at reality cool state
- Gii hn pht hin / Detection limit:
1
- Phm vi o / Range of measurement:
10-5 106
TCVN 6627-1: 2008
IEC 60034-1: 2004
IEC 60034-1: 2010
-
DANH MC PHP TH C CNG NHN LIST OF ACCREDITED TESTS
VILAS 215
AFL 01.09 Ln ban hnh: 5.10 Trang: 8/21
TT
Tn sn phm, vt liu c th
Materials or products tested
Tn phng php th c th The name of specific tests
Gii hn pht hin (nuc)/Phm vi o Detection limit (if
any)/range of measurement
Phng php th Test methods
25.
ng c in khng ng b ba pha cng sut t 100W tr ln
Three phase asynchronous electric
motors from 100W and higher power
o dng in v tn hao khng ti
Measure unload current and losses of motors
- phn gii / Resolution:
0,1V; 0,1A; 1,0 W(VA) - Phm vi o / Range of measurement:
1V 600V rms (AC+DC)
1A 1000A rms (AC+DC)
1W (VA) 600 kW (kVA) average
TCVN 6627-1: 2008
IEC 60034-1: 2004
IEC 60034-1: 2010
26.
Th bn in ca cch in ca cun dy i vi v my v gia cc cun dy
Test electric strength of insulation by A.C voltage at industrial frequency between windings and frame, one winding and other windings
- phn gii / Resolution:
0,1 kV; 0,1 mA
- Phm vi o / Range of measurement:
0,5 125kV; 1 mA 100 mA
TCVN 6627-1: 2008
IEC 60034-1: 2004
IEC 60034-1: 2010
27. ng c in khng ng b ba pha rotor ngn mch c cng sut t 0.55 kW tr
ln Three phase
asynchronous squirrel cage electrical motors
from 0.55kW and higher power
o in tr ca cc cun dy bng dng in mt chiu trng thi ngui
Measure resistance of windings by DC current at cool state
- Gii hn pht hin / Detection limit:
1
- Phm vi o / Range of measurement:
10-5 106
TCVN 6627-1: 2008
IEC 60034-1: 2004
IEC 60034-1: 2010
28.
o in tr cch in ca cc cun dy vi v my v gia cc cun dy
Measure insulation resistance by DC voltage between windings and frames, one winding and other windings
- phn gii / Resolution:
10 k; 0,01nA
- Phm vi o / Range of measurement:
100 k 5 T; 0,1nA999 A
TCVN 6627-1: 2008
IEC 60034-1: 2004
IEC 60034-1: 2010
-
DANH MC PHP TH C CNG NHN LIST OF ACCREDITED TESTS
VILAS 215
AFL 01.09 Ln ban hnh: 5.10 Trang: 9/21
TT
Tn sn phm, vt liu c th
Materials or products tested
Tn phng php th c th The name of specific tests
Gii hn pht hin (nuc)/Phm vi o Detection limit (if
any)/range of measurement
Phng php th Test methods
29.
ng c in khng ng b ba pha rotor ngn mch c cng sut t 0.55 kW tr
ln Three phase
asynchronous squirrel cage electrical motors
from 0.55kW and higher power
Th bn in ca cch in ca cun dy i vi v my v gia cc cun dy
Test electric strength of insulation by A.C voltage at industrial frequency between windings and frame, one winding and other windings
- phn gii / Resolution:
0,1 kV; 0,1 mA
- Phm vi o / Range of measurement:
0,5 125kV; 1 mA 100 mA
TCVN 6627-1: 2008
IEC 60034-1: 2004
IEC 60034-1: 2010
30. o rung ca ng c in
Measure vibration of motors
- Gii hn pht hin / Detection limit:
0,1 m/s2 Peak
0,1 mm/s RMS
0,001 mm P-P
- Phm vi o / Range of measurement:
1 199,9 m/s2 Peak
1 199,9 mm/s RMS
0,01 1,999 mm P-P
TCVN 6627-14: 2008
IEC 60034-14: 2003 with amendment 1: 2007
IEC 60034-14: 2007
31. o n ca ng c in
Measure noise of electrical motors
- Gii hn pht hin / Detection limit:
1 dB
- Phm vi o / Range of measurement:
30 dB 130 dB
TCVN 6627-9: 2011
IEC 60034-9: 2007
-
DANH MC PHP TH C CNG NHN LIST OF ACCREDITED TESTS
VILAS 215
AFL 01.09 Ln ban hnh: 5.10 Trang: 10/21
TT
Tn sn phm, vt liu c th
Materials or products tested
Tn phng php th c th The name of specific tests
Gii hn pht hin (nuc)/Phm vi o Detection limit (if
any)/range of measurement
Phng php th Test methods
32.
ng c in khng ng b ba pha rotor ngn mch c cng sut t 0.55 kW tr
ln Three phase
asynchronous squirrel cage electrical motors
from 0.55kW and higher power
Xc nh dng in v tn hao khng ti
Determine unload current and losses of motors
- phn gii / Resolution:
0,1V; 0,1A; 1,0 W (VA) - Phm vi o / Range of measurement:
1V 600V rms (AC+DC)
1A 1000A rms (AC+DC)
1W (VA) 600 kW (kVA) average
TCVN 6627-1: 2008
IEC 60034-1: 2004
IEC 60034-1: 2010
33.
Aptmt cp in p ti 1000V
Circuit breakers for voltage up to 1000V
Th nghim c tnh ct bo v
Test trip characteristics for protection
- Gii hn pht hin / Detection limit:
0,1 A; 0,01 s
- Phm vi o / Range of measurement:
1A 15 kA;
0,1 99999,9 s; 99 h 59 min
TCVN 6592-2: 2009
IEC 60947-2: 2009
34.
Th nghim chc nng bo v ngn mch
Test function of short-circuit protectors
- Gii hn pht hin / Detection limit:
0,1 A; 0,01 s
- Phm vi o / Range of measurement:
1A 15 kA;
0,1 99999,9 s; 99 h 59 min
-
DANH MC PHP TH C CNG NHN LIST OF ACCREDITED TESTS
VILAS 215
AFL 01.09 Ln ban hnh: 5.10 Trang: 11/21
TT
Tn sn phm, vt liu c th
Materials or products tested
Tn phng php th c th The name of specific tests
Gii hn pht hin (nuc)/Phm vi o Detection limit (if
any)/range of measurement
Phng php th Test methods
35.
Kh c in in p n v trn 1000V
Eletrical apparatus for voltages up to 1000V
and above 1000V
Xc nh cc gi tr tc ng
Determine trip values
- Gii hn pht hin / Detection limit:
0,01 V
0,01 A
0,001 s
- Phm vi o / Range of measurement:
0,1 600,0 V (AC, DC) 0,1 250,0 A
0,01 99999,9 s
LowVoltage:
TCVN 6592-1: 2009
IEC 60947-1: 2007
TCVN 6592-2: 2009
IEC 60947-2: 2009
TCVN 6592-4-1:2009
IEC 60947-4-1: 2002
IEC 60947-4-1: 2009
HighVoltage:
IEC 62271-102: 2003
IEC 62271-105: 2002
IEC 62271-107: 2005
36. o in tr cch in
Measure insulation resistance
- phn gii / Resolution:
10 k; 0,01nA
- Phm vi o / Range of measurement:
100 k 5 T; 0,1nA999 A
LowVoltage:
TCVN 6592-1: 2009
IEC 60947-1: 2007
TCVN 6592-2: 2009
IEC 60947-2: 2009
TCVN 6592-4-1:2009
IEC 60947-4-1: 2002
IEC 60947-4-1: 2009
HighVoltage:
IEC 62271-102: 2003
IEC 62271-105: 2002
IEC 62271-107: 2005
-
DANH MC PHP TH C CNG NHN LIST OF ACCREDITED TESTS
VILAS 215
AFL 01.09 Ln ban hnh: 5.10 Trang: 12/21
TT
Tn sn phm, vt liu c th
Materials or products tested
Tn phng php th c th The name of specific tests
Gii hn pht hin (nuc)/Phm vi o Detection limit (if
any)/range of measurement
Phng php th Test methods
37.
Kh c in in p n v trn 1000V
Eletrical apparatus for voltages up to 1000V
and above 1000V
Th bn cch in bng in p xoay chiu tn s cng nghip
Test electric strength of insulation by A.C voltages at industrial frequency
- phn gii / Resolution:
0,1 kV; 0,1 mA
- Phm vi o / Range of measurement:
0,5 125kV; 1 mA 100 mA
LowVoltage:
TCVN 6592-1: 2009
IEC 60947-1: 2007
TCVN 6592-2: 2009
IEC 60947-2: 2009
TCVN 6592-4-1:2009
IEC 60947-4-1: 2002
IEC 60947-4-1: 2009
HighVoltage:
IEC 62271-102: 2003
IEC 62271-105: 2002
IEC 62271-107: 2005
38.
o in tr tip xc ca cc tip im
Measure resistance of contacts in closing position
- phn gii / Resolution:
0,1
- Phm vi o / Range of measurement:
1 999,9 m
LowVoltage:
TCVN 6592-1: 2009
IEC 60947-1: 2007
TCVN 6592-2: 2009
IEC 60947-2: 2009
TCVN 6592-4-1:2009
IEC 60947-4-1: 2002
IEC 60947-4-1: 2009
HighVoltage:
IEC 62271-102: 2003
IEC 62271-105: 2002
IEC 62271-107: 2005
-
DANH MC PHP TH C CNG NHN LIST OF ACCREDITED TESTS
VILAS 215
AFL 01.09 Ln ban hnh: 5.10 Trang: 13/21
TT
Tn sn phm, vt liu c th
Materials or products tested
Tn phng php th c th The name of specific tests
Gii hn pht hin (nuc)/Phm vi o Detection limit (if
any)/range of measurement
Phng php th Test methods
39.
Kh c in in p n v trn 1000V
Eletrical apparatus for voltages up to 1000V
and above 1000V
Th pht nng
Test exothermic level (by become hot) of apparatus
- Gii hn pht hin / Detection limit:
0,1 A; 0,001 s; 0,1 oC
- Phm vi o / Range of measurement:
0,5 15 kA; (- 40 310 ) oC
0,01 99999,9s; 99 h 59 min
LowVoltage:
TCVN 6592-1: 2009
IEC 60947-1: 2007
TCVN 6592-2: 2009
IEC 60947-2: 2009
TCVN 6592-4-1:2009
IEC 60947-4-1: 2002
IEC 60947-4-1: 2009
HighVoltage:
IEC 62271-102: 2003
IEC 62271-105: 2002
IEC 62271-107: 2005
40.
Rle dng in nhit Thermal relays
Th c tnh thi gian-dng in
Test characteristic of time-currents
- Gii hn pht hin / Detection limit:
0,1 A; 0,001 s; 0,1 oC
- Phm vi o / Range of measurement:
0,5 15 kA; (- 40 310 ) oC
0,01 99999,9s; 99 h 59 min
TCVN 7883-8:2008
IEC 60255-8:1990
41.
Th tr v ca h thng tip xc ca rle nhit cc i ca khng kh xung quanh v gi tr cc i ca dng chnh nh
Test aptitude reseting contacts at maximal enviroment temperature and at maximal seting value
- Gii hn pht hin / Detection limit:
0,1 A; 0,001 s; 0,1 oC
- Phm vi o / Range of measurement:
0,5 15 kA; (- 40 310 ) oC
0,01 99999,9s; 99 h 59 min
TCVN 7883-8:2008
IEC 60255-8:1990
-
DANH MC PHP TH C CNG NHN LIST OF ACCREDITED TESTS
VILAS 215
AFL 01.09 Ln ban hnh: 5.10 Trang: 14/21
TT
Tn sn phm, vt liu c th
Materials or products tested
Tn phng php th c th The name of specific tests
Gii hn pht hin (nuc)/Phm vi o Detection limit (if
any)/range of measurement
Phng php th Test methods
42.
Rle dng in nhit Thermal relays
o in tr cch in
Measure insulation resistance by DC voltage
- phn gii / Resolution:
10 k; 0,01nA
- Phm vi o / Range of measurement:
100 k 5 T; 0,1nA999 A
TCVN 7883-8: 2008
IEC 60255-8: 1990
43.
Th pht nng cc b phn rle
Test exothermic level of components
- Gii hn pht hin / Detection limit:
0,1 A; 0,001 s; 0,1 oC
- Phm vi o / Range of measurement:
0,5 15 kA; (- 40 310 ) oC
0,01 99999,9s; 99 h 59 min
TCVN 7883-8: 2008
IEC 60255-8: 1990
44.
Th cc tip im theo kh nng chuyn mch bng cch tin hnh ng v ct cc tip im bng c kh hoc in
Test switching aptitude of contacts by mechanical control or electrical control
- Gii hn pht hin / Detection limit:
0,1 A; 0,001 s; 0,1 oC
- Phm vi o / Range of measurement:
0,5 15 kA; (- 40 310 ) oC
0,01 99999,9s; 99 h 59 min
TCVN 7883-8: 2008
IEC 60255-8: 1990
-
DANH MC PHP TH C CNG NHN LIST OF ACCREDITED TESTS
VILAS 215
AFL 01.09 Ln ban hnh: 5.10 Trang: 15/21
TT
Tn sn phm, vt liu c th
Materials or products tested
Tn phng php th c th The name of specific tests
Gii hn pht hin (nuc)/Phm vi o Detection limit (if
any)/range of measurement
Phng php th Test methods
45.
Rle dng in nhit Thermal relays
Th chu nhit
Test withstand by temperature
- Gii hn pht hin / Detection limit:
0,1 A; 0,001 s; 0,1 oC
- Phm vi o / Range of measurement:
0,5 15 kA;
(- 40 310 ) oC 0,01 99999,9s; 99 h
59 min
TCVN 7883-8: 2008
IEC 60255-8: 1990
46.
Th tc ng 8 ln dng chnh nh
Test trip value at 8 times of the seting value
- Gii hn pht hin / Detection limit:
0,1 A; 0,001 s; 0,1 oC
- Phm vi o / Range of measurement:
0,5 15 kA; (- 40 310 ) oC
0,01 99999,9s; 99 h 59 min
TCVN 7883-8: 2008
IEC 60255-8: 1990
47.
My ct in t ng dng in n 6300A in p n v trn
1000V
Circuit- breakers of current up to 6300A and voltages up and
obove 1000V
Kim tra kh nng lm vic ch di hn khi dng in ti danh nh
Check aptitude for continuous operation at full load current
- Gii hn pht hin / Detection limit:
0,1 A; 0,001 s; 0,1 oC
- Phm vi o / Range of measurement:
0,5 15 kA; (- 40 310 ) oC
0,01 99999,9s; 99 h 59 min
Low-voltage:
TCVN 6592-2: 2009
IEC 60947-2: 2009
High-Voltage:
IEC 62271-100: 2008
-
DANH MC PHP TH C CNG NHN LIST OF ACCREDITED TESTS
VILAS 215
AFL 01.09 Ln ban hnh: 5.10 Trang: 16/21
TT
Tn sn phm, vt liu c th
Materials or products tested
Tn phng php th c th The name of specific tests
Gii hn pht hin (nuc)/Phm vi o Detection limit (if
any)/range of measurement
Phng php th Test methods
48.
My ct in t ng dng in n 6300A in p n v trn
1000V
Circuit- breakers of current up to 6300A and voltages up and
obove 1000V
Th bn in ca cch in
Test electric strength of insulation by A.C voltages at industrial frequency
- phn gii / Resolution:
0,1 kV; 0,1 mA
- Phm vi o / Range of measurement:
0,5 125kV; 1 mA 100 mA
Low-Voltage:
TCVN 6592-2: 2009
IEC 60947-2: 2009
High-Voltage:
IEC 62271-100: 2008
49. o in tr cch in
Measure insulation resistance by DC voltage
- phn gii / Resolution:
10 k; 0,01nA
- Phm vi o / Range of measurement:
100 k 5 T; 0,1nA999 A
Low-Voltage:
TCVN 6592-2: 2009
IEC 60947-2: 2009
High-voltage:
IEC 62271-100: 2008
50.
o in p ri hoc in tr ca mch chnh (in tr tip xc ca tip im lc) Measure the drop voltage or resistance of contacts in closing position
- phn gii / Resolution:
0,1
- Phm vi o / Range of measurement:
1 999,9 m
Low-Voltage:
TCVN 6592-2: 2009
IEC 60947-2: 2009
High-voltage:
IEC 62271-100: 2008
51.
Kim tra hot ng ca b phn nh khp
Check the operation of release mechanism
- Gii hn pht hin / Detection limit:
0,01 V
0,01 A
0,001 s
- Phm vi o / Range of measurement:
0,1 600,0 V (AC, DC) 0,1 250,0 A
0,01 99999,9 s
Low-Voltage:
TCVN 6592-2: 2009
IEC 60947-2: 2009
High-Voltage:
IEC 62271-100: 2008
-
DANH MC PHP TH C CNG NHN LIST OF ACCREDITED TESTS
VILAS 215
AFL 01.09 Ln ban hnh: 5.10 Trang: 17/21
TT
Tn sn phm, vt liu c th
Materials or products tested
Tn phng php th c th The name of specific tests
Gii hn pht hin (nuc)/Phm vi o Detection limit (if
any)/range of measurement
Phng php th Test methods
52.
My ct in t ng dng in n 6300A in p n v trn
1000V
Circuit- breakers of current up to 6300A and voltages up and
obove 1000V
Kim tra hot ng ca cc tip im t do
Check the operation of free contacts
- Gii hn pht hin / Detection limit:
0,01 V
0,01 A
0,001 s
- Phm vi o / Range of measurement:
0,1 600,0 V (AC, DC) 0,1 250,0 A
0,01 99999,9 s
Low-Voltage:
TCVN 6592-2: 2009/
IEC 60947-2: 2009
High-voltage:
IEC 62271-100: 2008
53.
Kim tra hot ng ca b truyn
Check the operation of actuating mechanism
- Gii hn pht hin / Detection limit:
0,01 V
0,01 A
0,001 s
- Phm vi o / Range of measurement:
0,1 600,0 V (AC, DC) 0,1 250,0 A
0,01 99999,9 s
Low-Voltage:
TCVN 6592-2: 2009
IEC 60947-2: 2009
High-voltage:
IEC 62271-100: 2008
54.
Cp, dy dn v dy dn mm
Cables, wires and cords
o in tr ca rut dy dn in
Measure resistance of cable core, wire core and cord core
- Gii hn pht hin / Detection limit:
1
- Phm vi o / Range of measurement:
10-5 106
TCVN 6612: 2007
IEC 60228:2004
TCVN 6610-2: 2007
IEC 60227-2:2003
-
DANH MC PHP TH C CNG NHN LIST OF ACCREDITED TESTS
VILAS 215
AFL 01.09 Ln ban hnh: 5.10 Trang: 18/21
TT
Tn sn phm, vt liu c th
Materials or products tested
Tn phng php th c th The name of specific tests
Gii hn pht hin (nuc)/Phm vi o Detection limit (if
any)/range of measurement
Phng php th Test methods
55.
Cp, dy dn v dy dn mm
Cables, wires and cords
o in tr cch in v in tr ca lp v bo v ca dy cp, dy dn v dy dn mm bng in p mt chiu
Measure insulation resistance by DC voltage and resistance of protective cover of wires, cords and cables
- phn gii / Resolution:
10 k; 0,01nA
- Phm vi o / Range of measurement:
100 k 5 T; 0,1nA999 A
TCVN 6610-1:2007
IEC 60227-1:1998
TCVN 6610-2: 2007
IEC 60227-2:2003
56.
Cp in lc n 35 kV
Power cable with voltage up to 35kV
o in tr bng dng in mt chiu ca rut dy dn
Measure resistance of wire and cable core by DC current
- Gii hn pht hin / Detection limit:
1
- Phm vi o / Range of measurement:
10-5 106
TCVN 6612: 2007
IEC 60228:2004
57.
o in tr cch in
(PP. ngm trong nc ) Measure insulation resistance by DC voltage (cables soak in water)
- phn gii / Resolution:
10 k; 0,01nA
- Phm vi o / Range of measurement:
100 k 5 T; 0,1nA999 A
IEC 60502-1: 2004
IEC 60502-2: 2005
58.
Th bn in ca cch in bng in p cao AC v DC
Test electric strength of insulation by A.C voltage at industrial frequency and DC voltage
- phn gii / Resolution:
0,1 kV; 0,1 mA
- Phm vi o / Range of measurement:
0,5 125kV; 1 mA 100 mA
IEC 60502-1: 2004
IEC 60502-2: 2005
-
DANH MC PHP TH C CNG NHN LIST OF ACCREDITED TESTS
VILAS 215
AFL 01.09 Ln ban hnh: 5.10 Trang: 19/21
TT
Tn sn phm, vt liu c th
Materials or products tested
Tn phng php th c th The name of specific tests
Gii hn pht hin (nuc)/Phm vi o Detection limit (if
any)/range of measurement
Phng php th Test methods
59.
Vt liu cch in dng cho my in,
my bin p v kh c in
Electrical insulating materials for electrical
machinery, transformers and
apparatus
Th bn in cch in bng in p cao
Test electric strength of insulation by high voltage
- phn gii / Resolution:
0,1 kV; 10 A
- Phm vi o / Range of measurement:
0,5 80 kV; 0,1 50 mA
TCVN 6099-1: 2007
IEC 60060-1: 1989
60. So cch in
Dielectric- handle rod Th bn in bng in p xoay chiu tn s cng nghip (n 70kVac v dc) Test electric strength of insulation by A.C voltages at industrial frequency (up to 70kV AC and DC)
- phn gii / Resolution:
0,1 kV; 10 A
- Phm vi o / Range of measurement:
0,5 80 kV; 0,1 50 mA
TCVN 5587: 2008
IEC 60855: 1985
IEC 60855-1: 2009
61. ng cch in
Dielectric- gloves
TCVN 8084: 2009
IEC 60903: 2002
62. Thm cch in Dielectric- gloves
TCVN 8084: 2009
IEC 60903: 2002
63. Gng tay cch in
Dielectric- gloves
TCVN 8084: 2009
IEC 60903: 2002
64.
c quy kim st- niken, c quy axt-ch
Alkaline nikel-iron, lead-acid batteries
Th phng in 20oC
Test discharge of batteries at 20oC
- phn gii / Resolution:
0,1 V
0,1 A
1 min
0,1 Ah
- Phm vi o / Range of measurement:
1 280 V
1 300 A
1 min 99 h 59 min
1 9999,9 Ah
TCVN 7916-1: 2008 TCVN 6473: 1999
-
DANH MC PHP TH C CNG NHN LIST OF ACCREDITED TESTS
VILAS 215
AFL 01.09 Ln ban hnh: 5.10 Trang: 20/21
TT
Tn sn phm, vt liu c th
Materials or products tested
Tn phng php th c th The name of specific tests
Gii hn pht hin (nuc)/Phm vi o Detection limit (if
any)/range of measurement
Phng php th Test methods
65.
c quy kim st- niken, c quy axt-ch
Alkaline nikel-iron, lead-acid batteries
Th tui th theo chu k phng np
Test the lifetime of batteries following discharge and charge cycle
- phn gii / Resolution:
1 Siemens; 0,01 V
- Phm vi o / Range of measurement:
100 19990 Siemens
1,000 19,999 V DC
TCVN 7916-1: 2008
TCVN 6473: 1999
66.
Pin thng thng Primary Batteries
o in p ca pin
Measuring voltage of batteries
- phn gii / Resolution:
0,01V
- Phm vi o / Range of measurement: 0,1
1000 V DC
IEC 60086-1: 2006
67.
Xc nh thi gian phng in ca pin
Determine discharge time of batteries
- Gii hn pht hin / Detection limit:
0,01 V
0,01 A
0,01 s
- Phm vi o / Range of measurement:
0,1 600,0 V (AC, DC) 0,1 6,000 A (AC, DC)
0,1 99999,9 s
IEC 60086-2: 2006
68. Mi trng lm vic
Working Environment
o mc ting n ti ch lm vic
Measure noise at working place
- Gii hn pht hin / Detection limit:
1 dB
- Phm vi o / Range of measurement:
30 dB 130 dB
TCVN 3985:1999
69. o mc n ca my in quay
Measure noise of machines TCVN 6627-9: 2011
IEC 60034-9:2007
-
DANH MC PHP TH C CNG NHN LIST OF ACCREDITED TESTS
VILAS 215
AFL 01.09 Ln ban hnh: 5.10 Trang: 21/21
TT
Tn sn phm, vt liu c th
Materials or products tested
Tn phng php th c th The name of specific tests
Gii hn pht hin (nuc)/Phm vi o Detection limit (if
any)/range of measurement
Phng php th Test methods
70.
Rle tng t,
k thut s a chc nng
Multi-function relays, analog relays and
digital relays
Kim tra cc chc nng hot ng ca rle
Check all functions of relay
- phn gii / Resolution:
10 mV; 1 mA; 1 mHz; 0,1o ; 0,1 ms
- Phm vi o / Range of measurement:
1 150 V (4 pha AC) 1 300 V (1 pha AC)
1 180 V DC
10mA 15 A (3 pha AC)
10mA 45 A (1 pha AC)
10mA 15 A DC
DC 2000Hz
0,5 360o
1 ms 15264 h
IEC 60255-1: 2009
IEC 60255-8: 1990
IEC 60255-12: 1980
IEC 60255-13: 1980
IEC 60255-16: 1982
IEC 60255-127: 2010
IEC 60255-151: 2009
71. Kim tra cch in
Measure insulation resistance
- phn gii / Resolution:
10 k; 0,01nA
- Phm vi o / Range of measurement:
100 k 5 T; 0,1nA999 A
IEC 60255-5: 2000
72. Kim tra tin cy ca cc tip im
Check faith of contacts
- phn gii / Resolution:
0,1
- Phm vi o / Range of measurement:
0,5 40,00 M
IEC 60255-1: 2009