vivax cool 2014.pdf

Upload: feritfazliu

Post on 01-Jun-2018

245 views

Category:

Documents


3 download

TRANSCRIPT

  • 8/9/2019 VIVAX cool 2014.pdf

    1/36

    We reserve the right of eventual printing errors.1

    A i  r   c  o n d i t i oners  c a t a l o

     g  u e

     

       2   0

        1   4

    A + + 

       1  W 

     s  t a  n d

      b  y

     G 10  t ehno l o g y

          L  o   w

     

         n    o      i    s

        e

           I        F    e    e      l

         7    -

           f     a     n

          s

         p        e       e        d       s

            L     o     w

     

           h      e

          a        t          i     n      g 

       -      2       0     °      C

         L     o      w     c

          o      o      l      i     n

        g    -      1

          5    °      C

  • 8/9/2019 VIVAX cool 2014.pdf

    2/36

    We reserve the right of eventual printing errors.2

    model: ACP-18CC50GEEI

  • 8/9/2019 VIVAX cool 2014.pdf

    3/36

    We reserve the right of eventual printing errors.3

    2. Functions

    4. Vivax technology

    6. Function description

    7. Vivax multi split - DC inverter systems – introduction

    8. Products Overview

    10. WALL SPLIT SYSTEM - GEYI series

      GEEI series

      AELI series

    14. MOBILE AIR CONDITIONERS - AEH series

    15. FLOOR SPLIT SYSTEMS - CT-GEEI series

    16. FLOOR CEILING SPLIT SYSTEM - CF-GEEI series

    17. CASSETTE SPLIT SYSTEM - CC-GEEI series

    18. DUCT SPLIT SYSTEM - DT-GEEI series19. OUTDOOR UNITS CC/CF/DT-GEEI series

    20. DUAL SPLIT SYSTEM with two indoor units - AEEI series

    22. MULTI SPLIT SYSTEM - CIFM-GEEI series (wall)

      CTIFM-GEEI series (floor)

      CCIFM-GEEI series (cassette)

      DTIFM-GEEI series (duct)

      COFM-GEEI series (outdoor units)

    29. MULTI SPLIT SYSTEM - combination

    30. MULTI SPLIT SYSTEM - SUPER FREE MATCH

    31. MULTI SPLIT SYSTEM - SUPER FREE MATCH

    Distributor box, Branch pipe, Smart Zone Controller SZC-16

    32. MULTI SPLIT SYSTEM - SUPER FREE MATCH

    Allowable Length/Height Difference of Refrigerant Piping33. SUPER FREE MATCH - combinations

    Contents

  • 8/9/2019 VIVAX cool 2014.pdf

    4/36We reserve the right of eventual printing errors.2

    Function

    RELIABILITY

    COMFORT

    -15°C/-20°C HEATING

     The device can be used for heating at low outdoortemperatures with high efficiency.

    LOW AMBIENT KITAllows operation of the unit in cooling mode at low outdoor

    temperature.

    PTC HEATERAdditional heaters, one heater is used for heating oil in the

    compressor, and second one improves defrosting of the

    outdoor unit. Heater operation is controlled by the main

    processor. This management control enables a smooth and

    safe operation when the outdoor temperature reaches -15 °C.

    LOW TEMPERATURE STARTUP

     The device is functioning normally and begins to work andheat, even when outdoor temperature is lower than -15 ° C.

    LOW VOLTAGE STARTUP

     The unit could operate from 170V to 265V which is suitable

    for unstable power supply areas.

    INTELLIGENT DEFROSTING

    I-defrosting is only performed when needed, which reduces

    energy waste by eliminating the unnecessary defrostingprocess.

    SELF DIAGNOSIS DISPLAYING

    Display the error description on LED display for faster and

    easier solutions of the resulting problems.

    VALVE PROTECTION COVEROutdoor unit valves protection.

    REFRIGERANT LEAKAGE DETECT 

     The indoor unit will display error code “EC” when the

    system detects refrigerant leakage. This new technology

    can better protect the compressor.

    8°C HEATINGMaintain the room temperature steadily at 8° C and prevent

    the room from freezing by heating operation when nobody

    is at home for long in severe winter.

    7-FAN SPEEDS

    A large variety of different fan speeds of indoors unit enables

    quieter operation device which makes the stay in the areaenjoyable.

    3-FAN SPEEDS

     Three fan speeds of the indoor unit.

    I FEEL (follow me) The mini sensor in the remote controller can sense its

    surrounding temperature, and transmit the signal back

    to the indoor unit. So, the unit can adjust the air flow

    volume and temperature accordingly so as to provide

    maximum comfort.

    TURBO

    With this function, the air conditioner will maximize the

    output of cooling or heating capacity, make the room

    cool down or heat up rapidly, and attain the desired

    temperature in the shortest time.

    INTELLIGENT ANTI-COLD-AIR FUNCTION

    Conventional anti-cold-air function works only

    by evaporator temperature. Vivax intelligent anti-

    cold-air function works by both evaporator and

    ambient temperature, more accurate control ensure

    comfortable feeling.

    QUIET DESIGN

     The special design of the air blower provides dampingand noise reduction during operation.

    CLOCK DISPLAY

    Digital clock display is enabled on LED display of device.

    TEMPERATURE COMPENSATION 

     Temperature Compensation.

    12 GRADE INDOOR FAN SPEED AELI SERIES

    9,12,18K

    Improve indoor fan speeds from 6 grades (SH/H/M/L/S/SS) to 12 grades (SH/H+/H/H-/M+/M/M-/L+/L/L-

     /S/SS), ensure more accurate control and bring more

    comfortable air flow.

    5 GRADES OUTDOOR FAN SPEED AELI SERIES

    9,12,18K

    Upgrade outdoor fan speeds from 3 grades to 5 grades.

    According to the temperature difference, the outdoor

    unit can change the outdoor fan speed automatically

    to realize high heat exchange efficiency and save

    energy.

  • 8/9/2019 VIVAX cool 2014.pdf

    5/36We reserve the right of eventual printing errors.3

    HEALTH

    PRACTICALITY

    ENERGY SAVING

    SELF CLEANING

    By pressing the button “CLEAN” on the remote control, the devicewill automatically start with cleaning the indoor unit. This function

    will eliminate the bacteria and their reproduction, and the air

    becomes cleaner and fresher.

    DRY MOULD PROOF The fan remains to work after turning off the device in order to dry

    up the moisture that remains in the indoor unit.

    COLD CATALYST FILTER

    AUTO OPERATION

     The device offers the possibility of adjusting the automatic mode.

    By selecting this function, the device automatically determines

    the fan speed of the indoor unit and mode, comparing the set

    temperature and current conditions in the area.

    MEMORY FUNCTIONWhen the power is off and then on, the unit automatically restores

    the previous function settings.

    LED DISPLAY

    LED display functions overview.

    TIMER Timer allows initiation and termination of devices from within a

    period of 24 hours.

    WIDE ANGLE LOUVERS SYSTEM

    Distributes a stream of air to a wider area , to every corner of theworkspace.

    COMFORTABLE SLEEP FUNCTION

     Temperature is slightly rising or fallingautomatically in order to preserve the pleasant

    room temperature, and also reduce energyconsumption.

    1W STANDBY

     0,5W STANDBY

  • 8/9/2019 VIVAX cool 2014.pdf

    6/36We reserve the right of eventual printing errors.4

    Commission Delegated Regulation (EU) No 626/2011

    Technological developments in the energy efficiency improvement of air conditioners have been very rapid in recent years. This has allowed European

    Authority to introduce stringent minimum energy efficiency requirements and led to a process of introducing new energy labelling schemes based onseasonal performance. Today’s appliances, excluding single and double duct air conditioners, that achieve the highest efficienc y levels have largely surpassedthe A efficiency levels established by Directive 2002/31/EC.

    This Regulation introduces two energy efficiency scales based on the primary function and on specific aspects important to consumer. Given that airconditioners are used mainly in part-load conditions, the efficiency testing should be changed to a seasonal efficiency measurement method, except forsingle and double duct air conditioners. The seasonal measurement method takes better into account the benefits of the inverter driven technology and theconditions in which these appliances are used. The new efficiency calculation method with an Ecodesign implementing measure setting minimum energyefficiency requirements higher than the current A level, will lead to a reclassification of these appliances. Consequently, split, window and wall air conditionersshould have a new A-G energy efficiency class scale with a “+” added on the top of the scale every two years until the A+++ class has been reached.

    Vivax technologyHIGH EFFICIENCYVivax models from residential tocommercial are reaching New classA ranking, the highest level thatis now shown on energy label in

    European union.

    New Energy Labelling Requirement(EU) 626/2011

    • Three climate zones for heating(Average zone is mandatory, warmerand colder zone are voluntary)• Seasonal eciency (performancebased on multiple part loadscalculation)Sound power level• Rated eciency indicates

    performance only data ratedcondition.Seasonal efficiency indicatesperformance at an entire coolingand heating season, which bettermatches the actual operation.

    0.5W StandbyIntelligent on-off technology enables Vivaxproducts automatically enter energy-savingmode when on standby mode, cut energyconsumption from conventional 5W to 0.5Wwhich counts 90% of saving.

    Intelligent Anti-cold-air FunctionConventional anti-cold-air function worksonly by evaporator temperature. Vivaxintelligent anti-cold-air function works by

    both evaporator and ambient temperature,more accurate control ensure comfortablefeeling.

    Wide Operation RangeUp to 25 stages (F1-F25) of compressor frequency, andfrequency range increased around 70%. More comfortableand energy saving due to smooth and accurate control.With advanced frequency-adjusting technology,compressor preheating function and the electrical heatingbelts, the unit can operate heating as low as -20°C.

    Power Factor Correction(PFC) Technology

    With advanced partialactive PFC control, theinput current waveform andvoltage waveform get phasesynchronization, more than97% of the input powersupply is used effectively,which greatly improve powertransformation efficiency.

    Brushless DC Fan Motor

     The brushless DC fan motorallows fine rotation control,which reduces energyconsumption. The efficiencyof brushless DC motor is upto 35% higher than that of

    the equivalent AC motor.

  • 8/9/2019 VIVAX cool 2014.pdf

    7/36We reserve the right of eventual printing errors.5

    quickly

    reaches

    the desired

    temperature

    for 

    Inverter 

    ne-inverter 

    fix-speedhot

    hot

    comfortable

    cold

    cold

    Ultra low frequency torque control

    High-speed DSP chip

    Environment-friendly R410A

    refrigerant

    Ultra-low noise control

    Automatic voltage adaptation

    High reliability

    Wide frequency precise control

    UHF flux-weakening control

    Computer simulation control

    Power factor correction technology

    Innovative DC inverter technology precisely and in

    every given moment and in all working conditions

    ensures cooling and heating capacity according to

    given space conditions. With the purpose to improve

    efficiency in heating mode, Vivax DC inverter air conditioner has developed technology that

    enables undisturbed work even up to -20 °C – G10 Inverter technology.

    Owing to a special type of oils that are not losing attributes (primarily viscosity) at low

    temperatures functionality of air conditioning goes seamlessly even at low temperatures.

    Besides G10 Inverter technology Vivax DC inverter air conditioners have retained the possibility

    to work in heating mode under low temperatures (up to -15 °C) due to additional heaters, it

    depends on the air conditioner series whether the heaters are installed into compressor or

    into condenser. One heater heats oil in the compressor while other improves defrosting of

    outdoor unit. Operation of those heaters is controlled by a main processor which receivesdata from outdoor unit sensor important for normal operation. Standard air conditioners

    have compressors that usually operate under constant speed. Inverter technology is the only

    technology that follows speed operation electronically. Compressor is operating under the

    highest speed if there is a big difference between default temperature and room temperature.

    When default temperature is reached compressor slows down. Inverter operation system

    saves up to 50% of energy. If the room temperature is high, air conditioner will operate under

    full power until default temperature is reached. Once default temperature is reached the

    operational power is decreased sufficiently enough to evenly maintain default temperature.

     Thereby, sudden changes in room temperature are being avoided and significant energy

    savings is accomplished. There is no frequent turning on and turning off of device that is

    additionally overloading electricity grid, therefore, “draft” syndrome is being avoided.

    ADVANTAGES-precise regulation of default temperature

    -fast reaching of default temperature-reduced temperature variation

    -higher comfort of conditioned space

    -possibility of heating even on -20°C

    -saving energy-no power strokes

  • 8/9/2019 VIVAX cool 2014.pdf

    8/36We reserve the right of eventual printing errors.6

    Funtions for Low Ambient Temperature

    8°C Heating

    Maintain the room temperature steadily at 8°C and prevent theroom from freezing by heating operation when nobody is athome for long in severe winter.

    3 Sleep Curves

     • Mod 1: indoor temperature automatically rises (when

    cooling) or drops (when heating)• Mod 2: featuring unique refreshment function, the

    temperature is automatically adjusted to be a little lower

    before you wake up.

    • Mod 3: You could design your own sleep curve under DIY

    mode.

    Function description

    Time

    Temperature

    Sleep Curve for Cooling

    Intelligent Defrosting

      Vivax intelligent defrosting Generally defrost

    Maximize warm comfort with shorter defrosting time. Traditional defrosting works by setting time. E.g. defrosting process is onfor 10mins for every 50 mins. VIVAX I-Defrosting is only performen whenneeded, which redusces energy waste by eliminating the unnecessarydefrosting process.

     

    -15°C Cooling

    Cooling at -15°C while keep a reliable operation. As the outdoortemperature changes, the frequency of compressor and thespeed of fan adjustus accordingly.

    -20°C Heating

    Operate finely when heating at -20°C. It is supported by VIVAX’selectrical heating chassis, preheating technology and frequency-adjusting compressor.

  • 8/9/2019 VIVAX cool 2014.pdf

    9/36We reserve the right of eventual printing errors.7

    Bio filtar IonizatorCatechin filtar Active carbon filter

    In this year Vivax presents you the forth generation of multi split DC

    inverter air conditioners which are ideal solution for conditioning of

    your business or residential spaces.

    All devices are designed to please users and space requests regarding

    cooling and heating. New technological solutions enable high power

    efficiency of one device under all climate conditions whether used for

    cooling or for heating.

    Vide capacity range of outdoor units (from 5.00 – 16.50 kW) and

    possibility to connect maximum 9 indoor units allows far-reaching

    of this devices by emphasising commercial and residential premises.

     The maximum length of installation is 145m* which allows easy

    positioning of device regarding relation outdoor unit and external

    object dimensions, therefore it is now very simple to position outdoor

    unit on the roof or on the backyard side without disturbing external

    appearance. Indoor units come in three different types: wall mounted,

    cassette, floor and it is possible to choose between 8 different indoor

    units with capacity range: 2.10 - 7.10 kW. Attractive design and low

    noise level will provide comfortable atmosphere.

    Apartments, flats, family houses, office space, shops, restaurants and

    special purpose facilities are just a part of spaces that Vivax multi split

    DC Inverter devices can heat or cool.

    Durability of this device, acceptable price and A class of energy

    efficiency are the guarantee of the best choice which pust Vivax multi

    split DC Inverter among the leading air conditioners in this segment.

    Bacteria Dust NH3

    HCHO Fungi Microbes Smoke Pollen Anions

    ACTIVE CARBON FILTARActive carbon filter is produced out of activated carbonl

    and electrostatic fibre material. It absorbs different kinds

    of materials either in gas or in liquid form. This filter has big

    capacity, capability of fast absorption of harmful gasses

    (such as ammonium and hydrogen sulphide) and other

    odours. Electrostatic fibre filter collects small particles of

    dust, smoke and animal hairs to prevent allergic reactions

    by forming a specific position on the surface of the filter.

    BIO FILTERBio filter consists of special biological enzymes and eco

    filters. Eco filter collects small particles of dust, bacteria,

    fungus and microbes. Biological enzymes remove bacteria

    by dissolving their cell walls and remove the possibility to

    re-pollute the air in the room.

    IONIZERAnions are taking care of your body by stimulating

    circulation, improvement of your lungs capacity and

    preventing airway diseases (e.g. asthma). Negative ions

    are eliminating dust and smoke, when air circulates

    through the ionizer, anions automatically start to act. The

    amount of anions can reach maximum of 1.000.000 cm3.

    Anions are removing chemical gases and dust particles.

    WARRANTY

    Warranty period for VIVAX COOL air conditions is 36 months with obligatory annual service performed by authorised servicecentre. Detailed information regarding warranty and list of authorised service centres can be found on www.vivax.com

    I FEELDevices with this function have built in sensor on

    the remote control. This sensor enables temperature

    measuring in a direct vicinity of the remote control and

    such information is being sent to the indoor unit which

    then starts to heat or cool. Such temperature control

    enables precise and more comfortable environment as

    well as energy saving. If during heating or cooling mode

    remote control registers that the temperature is higher/

    lower than default temperature, the device will start

    adjusting and creating more comfortable environment.

    If during heating/cooling mode the remote control

    registers that the temperature is higher/lower from

    default temperature, it will automatically shut down the

    compressor with the purpose to save energy.

    DRY MOULD PROOFIf your device has this function and you turn off the wholedevice, regardless of the mode heating/cooling, indoor

    fan will continue to rotate in low speed to dry out internal

    components and parts. This function keeps interior clean

    and dry and it prevents emergence of mould and odours

    CATECHIN FILTERFilter is produced out of durable fibre net that collects

    dust form the air and prevents spreading of bacteria and

    viruses. Filter efficiency is ≥ 95%.

    Filter options

    *model ACP-56COFM164GEEI

    VIVAX multi split

    DV inverter systems

  • 8/9/2019 VIVAX cool 2014.pdf

    10/36

    We reserve the right of eventual printing errors.8

    FLOOR

    SPLIT SYSTEMS CT-GEEI3.5k W 5.2kW

    FLOOR CEILING

    SPLIT SYSTEMSCF-GEEI 5.0k W 10.0kW7.0kW

    CASSETTE

    SPLIT SYSTEM CC-GEEI

    3.5kW

    11kW

    5.0kW

    14kW 16kW

    DUCT

    SPLIT SYSTEMDT-GEEI 7.0kW 10.0kW 11.5W

    DUAL SPLIT SYSTEM AEEI2x

    2.6kW

    Products Overview

    14kW 16kW

    7kW 10kW

    14kW 16kW

    Photo Series Capacity

    WALL

    SPLIT SYSTEM

    GEYI 3.5kW 5.3kW

    GEEI 5.2kW3.5kW 6.4kW

    AELI 2.8kW 5.3kW3.5kW

    MOBILE AIR

    CONDITIONERSAEH 2.6kW 3.5kW

    2.7kW

  • 8/9/2019 VIVAX cool 2014.pdf

    11/36

    We reserve the right of eventual printing errors.9

      VIVAX cool 2014.

    Photo Series Capacity

        M    U    L    T    I    S    P    L

        I    T    S    Y    S    T    E    M    S

    Wall mounted

    indoor unitCIFM-GEEI

    2.1kW

    3.5kW

    2.6kW

    5.3kW

    Floor mounted

    indoor unitCTIFM-GEEI 2.6k W 3.5kW 5.3kW

    Cassette

    indoor unit

    CCIFM-GEEI 3.5kW 4.5kW

    Duct

    indoor unitsDTIFM-GEEI 5.0kW 7.1kW

    Outdoor unit COFM-GEEI5.0kW

    8.0kW

    7.1kW

    12.1kW

    Outdoor unit

    COFM-GEEI

    SUPER FREE

    MATCHI

    14kW 16kW

  • 8/9/2019 VIVAX cool 2014.pdf

    12/36

    We reserve the right of eventual printing errors.10

    High Efficiency

    Ionizer

    G10 tehnology

    1W standbyI feel

    Heating operating temperature range -20°C

    Cooling operating temperature range -15°C

    Condenser and compressor’s heaters

    Intelligent defrosting

    7-fan speeds indoor unit

    Bio filter

    WALL SPLIT SYSTEMDC inverter 

    GEYI series

    ACP-18CH50GEYIACP-12CH35GEYI

    Energyefficiencyclass

    Model ACP-12CH35GEYI ACP-18CH50GEYI

    Capacity Cooling 3500(700-4500) W 5275(1260~6600) WHeating 3650(720~5500) W 5800(1120~6800) W

    Refrigerant R410A R410AEnergy efficiency class Cooling A++ A+

    Heating A++ AEnergy Efficiency SEER 7.0 5.6

    SCOP 4.6 3.8Design load for heating (Pdesignh) 3800 W 4500 WInput power Cooling 900 W 1514 W

    Heating 895 W 1600 WAirflow ≤770 m³/h ≤850 m³/hDehumidifying capacity 1.4 L/h 1.8 L/hSound pressure level Indoor unit ≤43 dB(A) ≤48 dB(A)

    Outdoor unit ≤50 dB(A) ≤56 dB(A)Sound power level Indoor unit ≤59 dB ≤58 dB

    Outdoor unit ≤63 dB ≤65 dBOuter Diameter of Liquid Pipe 1/4” 1/4”Outer Diameter of Gas Pipe 3/8” 1/2”Connection wire 4x1.5 mm² 4x2.5 mm²Power supply ~220-240V/1/50Hz; indoor unitMax. length of pipe 20 m 25 mMax elevation 10 m 10 mStandard length 5 m 5 mAdditional refrigerant 20 g/m 20 g/mWall bracket distance(outdoor) 550 mm 560 mmWorking range -20°C≤T≤43°C -20°C≤T≤43°C

    Net dimensions Indoor unit 866x292x209 mm 940×298×200 mmOutdoor unit 899x596x378 mm 955×700×396 mm

    Net weight Indoor unit 11.0 kg 13.0 kgOutdoor unit 43.0 kg 45.0 kg

    3 Sleep Curves

     • Mod 1: indoor temperature automatically rises (when

    cooling) or drops (when heating)

    • Mod 2: featuring unique refreshment function, the

    temperature is automatically adjusted to be a little lower

    before you wake up.

    • Mod 3: You could design your own sleep curve under DIY

    mode.

    Time

    Temperature

    Sleep Curve for Cooling

  • 8/9/2019 VIVAX cool 2014.pdf

    13/36

    We reserve the right of eventual printing errors.11

    model: ACP-18CH50GEYI

  • 8/9/2019 VIVAX cool 2014.pdf

    14/36

    We reserve the right of eventual printing errors.12

    GEEI series

    High Efficiency

    Heating operating temperature range -15°C

    Cooling operating temperature range -15°C

    Intelligent defrosting

    G10 tehnology

    Ionizer

    Bio filter

    1W standby

    I feel

    ACP-22CH65GEEI

    WALL SPLIT SYSTEMDC inverter 

     ACP-18CH50GEEI

    Energyefficiencyclass

    ACP-12CH35GEEI

    ACP-09CH25GEEI

    Model ACP-09CH25GEEI ACP-12CH35GEEI ACP-18CH50GEEI ACP-22CH65GEEI

    Capacity Cooling 2700 (600-3200) W 3500 (600-3900) W 5275 (1260-6600) W 6450 (2530-6800) WHeating 2800 (800-3600) W 4000 (880-4400) W 5800 (1120-6800) W 7000 (2530-7600) W

    Refrigerant R410A R410A R410A R410AEnergy efficiency class Cooling A+ A++ A+ A

    Heating A A+ A AEnergy Efficiency SEER 5.6 6.1 5.6 5.1

    SCOP 3.8 4.0 3.8 3.8Design load for heating (Pdesignh) 2800 W 3200 W 4500 W 5800 WInput power Cooling 870 W 1170 W 1625 W 2180 W

    Heating 900 W 1200 W 1760 W 2220 WAirflow ≤600 m³/h ≤600 m³/h ≤850 m³/h ≤1000 m³/hDehumidifying capacity 0.8 L/h 1.40 L/h 1.8 L/h 2.0 L/hSound pressure level Indoor unit ≤41 dB(A) ≤42 dB(A) ≤48 dB(A) ≤51 dB(A)

    Outdoor unit ≤51 dB(A) ≤53 dB(A) ≤56 dB(A) ≤58 dB(A)Sound power level Indoor unit ≤54 dB ≤54 dB ≤58 dB ≤63 dB

    Outdoor unit ≤63 dB ≤63 dB ≤63 dB ≤68 dBOuter Diameter of Liquid Pipe 1/4” 1/4” 1/4” 1/4”Outer Diameter of Gas Pipe 3/8” 3/8” 1/2” 5/8”Connection wire 4*1.5 mm ² 4*1.5 mm ² 4*1.5 mm ² 4*1.5 mm ²Power supply ~220-240V/1/50Hz; indoor unitMax. length of pipe 15 m 15 m 25 m 25 mMax elevation 10 m 10 m 10 m 10 mStandard length 5 m 5 m 5 m 5 mAdditional refrigerant 20 g/m 20 g/m 20 g/m 50 g/mWall bracket distance(outdoor) 510 mm 510 mm 560 mm 610 mmWorking range -15°C≤T≤43°C - 15°C≤T≤43°C -15°C≤T≤43°C - 15°C≤T≤43°C

    Net dimensions Indoor unit 845X180X275 845X180X275 940×298×200 1007×315×219Outdoor unit 776x540x320 776x540x320 955x700x396 980×427×790

    Net weight Indoor unit 9 kg 9 kg 13 kg 14 kgOutdoor unit 28 kg 29 kg 45 kg 60 kg

  • 8/9/2019 VIVAX cool 2014.pdf

    15/36

    We reserve the right of eventual printing errors.13

    Bio filter

    1W standby

    Heating operating temperature

    range -15°C

    12-fan speeds indoor unit (Quietdesign)

    Refrigerant Leakage Detect

     Temp compensation

    Automatic defrosting

     Turbo mode

    Sleep mode

    24h timer

    LED display

    Self Diagnosis displaying

    WALL SPLIT SYSTEMDC inverter 

    ACP-09CH25AELIACP-12CH35AELI ACP-18CH50AELI

    Energyefficiencyclass

    AELI series

    Power Factor Correction (PFC) TechnologyWith advanced partial active PFC control, the input

    current waveform and voltage waveform get phasesynchronization, more than 97% of the input powersupply is used effectively, which greatly improve power

    transformation efficiency.

    Model ACP-09CH25AELI ACP-12CH35AELI ACP-18CH50AELI

    Capacity Cooling 2638(1284-3218) W 3517(1202-3933) W 5275(1917-5730) WHeating 2931(803-3271) W 3810(1011-3998) W 5569(1386-6225) W

    Refrigerant R410A R410A R410AEnergy efficiency class Cooling A A A++

    Heating A A AEnergy Efficiency SEER 5.5 5.5 6.5

    SCOP 3.8 3.8 3.8Design load for heating (Pdesignh) 2200 W 2700 W 4700 WInput power Cooling 1240 W 1510 W 2200 W

    Heating 1170 W 1430 W 2220 WAirflow ≤400 m³/h ≤500 m³/h ≤850 m³/hDehumidifying capacity 1.0 L/h 1.1 L/h 1.7 L/hSound pressure level Indoor unit ≤37 dB(A) ≤40 dB(A) ≤41 dB(A)

    Outdoor unit ≤56 dB(A) ≤55 dB(A) ≤58 dB(A)Sound power level Indoor unit ≤55 dB ≤54dB ≤56 dB

    Outdoor unit ≤63 dB ≤63dB ≤65 dBOuter Diameter of Liquid Pipe 1/4” 1/4” 1/4”Outer Diameter of Gas Pipe 3/8” 3/8” 1/2”Connection wire 5*1.5 mm ² 5*1.5 mm ² 5*2.5 mm ²Power supply ~220-240V/1/50Hz; outdoor unitMax. length of pipe 25 m 25 m 30 mMax elevation 10 m 10 m 20 mStandard length 5 m 5 m 5 mAdditional refrigerant 15 g/m 15 g/m 15 g/mWall bracket distance(outdoor) 549 mm 549 mm 530 mmWorking range -15°C≤T≤50°C -15°C≤T≤50°C -15°C≤T≤50°C

    Net dimensions Indoor unit 710x190x250 mm 790x198x265 mm 920x223x292 mmOutdoor unit 780x250x540 mm 780x250x540 mm 760x285x590 mm

    Net weight Indoor unit 6.5 kg 8 kg 11 kgOutdoor unit 29.5 kg 29.5 kg 35 kg

  • 8/9/2019 VIVAX cool 2014.pdf

    16/36

    We reserve the right of eventual printing errors.14

    0,5W standby

    Memory function (auto restart)

    Anti Cool Air design

    Automatic defrosting

    Dehumidifying

    Sleep mode

    24h timer

    LED displaySelf Diagnosis displaying

    MOBILE AIR CONDITIONERSMobile air conditioners

    Energyefficiencyclass

    AEH series

    0.5W Standby

    Intelligent on-off technology enables Vivax

    products automatically enter energy-saving

    mode when on standby mode, cut energy

    consumption from conventional 5W to 0.5W

    which counts 90% of saving.

    Model ACP-09PT25AEH ACP-12PT35AEH

    Capacity Cooling 2600 W 3500 WHeating 2500 W 2900 W

    Refrigerant R410A R410AEnergy efficiency class Cooling A A

    Heating A+ A+Energy Efficiency EER 2.6 2.6

    COP 2.6 2.6SEERSCOP

    Design load for heating (Pdesignh)Input power Cooling 1010 W 1350 W

    Heating 955 W 1130 WAirflow ≤370 m³/h ≤370 m³/hDehumidifying capacity 1.0 L/h 1.2 L/hSound pressure level Indoor unit ≤51 dB(A) ≤51 dB(A)

    Outdoor unit

    Sound power level Indoor unit ≤64 dB ≤65 dBNet dimensions Indoor unit 467x397x765 mm 467x397x765 mmNet weight Indoor unit 30.5 kg 34 kg

  • 8/9/2019 VIVAX cool 2014.pdf

    17/36

    We reserve the right of eventual printing errors.15

    8°C heating

    I feel

    Heating operating

    temperature range -15°CCooling operating temperature range -15°C

    Memory function (auto restart)

    Dry Mould Proof 

     Turbo mode

    24h timer

    Sleep modeLED display

    Self Diagnostis displaying

     

    FLOOR SPLIT SYSTEMSDC inverter 

    ACP-12CT35GEEI

    ACP-18CT50GEEI

    Energyefficiencyclass

    CT-GEEI series

    8°C Heating

    Maintain the room temperaturesteadily at 8°C and prevent the roomfrom freezing by heating operation

    when nobody is at home for long insevere winter.

     

    Model ACP-12CT35GEEI ACP-18CT50GEEI

    Capacity Cooling 3500 (600-3950) W 5200 (1260-6600) W

    Heating 3650 (600-4700) W 5500 (1120~6800) WRefrigerant R410A R410AEnergy efficiency class Cooling A++ A+

    Heating A AEnergy Efficiency SEER 6.1 5.6

    SCOP 3.8 3.8Design load for heating (Pdesignh) 3500 W 5200 WInput power Cooling 1100 W 1760 W

    Heating 1100 W 1600 WAirflow ≤600 m³/h ≤650 m³/hDehumidifying capacity 1.2 L/h 1.8 L/hSound pressure level Indoor unit ≤42 dB(A) ≤48 dB(A)

    Outdoor unit ≤53 dB(A) ≤56 dB(A)Sound power level Indoor unit ≤54 dB ≤58 dB

    Outdoor unit ≤63 dB ≤63 dBOuter Diameter of Liquid Pipe 1/4" 1/4"Outer Diameter of Gas Pipe 3/8" 1/2"Connection wire 4x1.5 mm² 4x1.5 mm²Power supply ~220-240V/1/50Hz; indoor unitMax. length of pipe 20 m 25 mMax elevation 10 m 10 mStandard length 5 m 5 mAdditional refrigerant 20 g/m 20 g/mWall bracket distance(outdoor) 540 mm 560 mmWorking range -15°C≤T≤48°C -15°C≤T≤48°C

    Net dimensions Indoor unit 700×215×600 mm 700x215x600 mmOutdoor unit 848×540×320 mm 955×700×396 mm

    Net weight Indoor unit 15.0 kg 15.0 kgOutdoor unit 33.0kg 46.0kg

  • 8/9/2019 VIVAX cool 2014.pdf

    18/36

    We reserve the right of eventual printing errors.16

    FLOOR CEILING SPLIT SYSTEMDC inverter 

    Additional wired controler

    8°C heating

    Heating operating

    temperature range -15°C

    Low Ambient Cooling

    Function

    Memory function (auto

    restart)

    24h timer

    1W standby

    Sleep mode

    LED display

    Self Diagnosis displaying

     

    Energyefficiencyclass

    CF-GEEI series

    Model ACP-18CF50GEEI ACP-24CF70GEEI ACP-36CF100GEEI ACP-48CF140GEEI ACP-60CF176GEEI

    Capacity Cooling 5000 (1600~5800) W 7000 (2400~8200) W 10000 (3200~11000) W 14000 (6000~14800) W 16000 (6350~16500) W

    Heating 5600 (1400~6800) W 8400 (2400~9000) W 12000 (2900~14000) W 16000 (5200-18000) W 17000 (5500~20000) W

    Refrigerant R410A R410A R410A R410A R410A

    Energy efficiency class Cooling A A A C C

    Heating A A A B A

    Energy efficiency EER 2.98 2.86

    COP 3.52 3.61

    SEER 5.1 5.1 5.1SCOP 3.8 3.8 3.8

    Design load for heating (Pdesignh) 4500 W 7000 W 9200 W 11800 W 13000 W

    Input power Cooling 1550 2180 3500 4800 W 5750 W

    Heating 1550 2210 3550 4300 W 4700 W

    Airflow ≤1000 m3/h ≤1200 m3/h ≤2000 m3/h ≤2300 m³/h ≤2500 m³/h

    Dehumidifying capacity 1.9 L/h 2.2 L/h 3.1 L/h 4.5 L/h 5.0 L/h

    Sound pressure level Indoor unit ≤ 42 dB (A) ≤ 47 dB (A) ≤ 53 dB (A) ≤ 56 dB (A) ≤ 58 dB (A)

    Outdoor unit ≤ 56 dB (A) ≤ 57 dB (A) ≤ 61 dB (A) ≤ 59 dB (A) ≤ 63 dB (A)

    Sound power level Indoor unit ≤ 58 dB ≤ 62 dB ≤ 65 dB ≤ 68 dB ≤ 71 dB

    Outdoor unit ≤ 64 dB ≤ 65 dB ≤ 70 dB ≤ 70 dB ≤ 75 dB

    Outer Diameter of Liquid Pipe 1/4 " 3/8 " 3/8 " 3/8“ 3/8"

    Outer Diameter of Gas Pipe 1/2 " 5/8 " 5/8 " 5/8 " 3/4"

    Connection wirepower supply OU: 3*1.5 mm ²;power supply IU: 3*1.0 mm ²;connection wire: 2*0.75 mm ²

    power supply OU: 3*2.5 mm ²;power supply IU: 3*1.0 mm ²;connection wire: 2*0.75 mm ²

    power supply OU: 3*2.5 mm ²;power supply IU: 3*1.0 mm ²;connection wire: 2*0.75 mm ²

    power supply OU: 3*5 mm ²;power supply IU: 3*1.0 mm ²;connection wire: 2*0.75 mm ²

    power supply OU: 5*2.5 mm ²;power supply IU: 3*1.0 mm ²;connection wire: 2*0.75 mm ²

    Power supply ~220-240V/1/50Hz; indoor & outdoor unit~380~415V; 50Hz;3ph;indoor & outdoor unit

    Max. length of pipe 20 m 30 m 30 m 50 m 50 m

    Max elevation 15 m 15 m 15 m 30 m 30 m

    Standard length 5 m 5 m 5 m 5 m 5 m

    Additional refrigerant 30 g/m 60 g/m 60 g/m 60 g/m 60 g/m

    Wall bracket distance(outdoor) 560 mm 610 mm 631 mm 572 mm 620 mm

    Working range -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C

    Net dimensions Indoor unit 1220*225*700 mm 1220*225*700 mm 1420*245*700 mm 1700*245*700 mm 1700*245*700 mm

    Outdoor unit 955*396*700 mm 980*427*790 mm 1107*440*1100 mm 958*412*1349 mm 1085*427*1365 mm

    Net weight Indoor unit 39 kg 40 kg 48 kg 56 kg 59 kg

    Outdoor unit 47 kg 67 kg 92 kg 105 kg 126 kg

    Workablewith SZC-16

  • 8/9/2019 VIVAX cool 2014.pdf

    19/36

    We reserve the right of eventual printing errors.17

    Additional wired controler8°C heating

    Built-in drain pump

    Heating operatingtemperature range -15°C

    Low Ambient Cooling

    Function

    Memory function

    (auto restart)

    24h timer

    1W standby

    LED display

    Self Diagnosis displaying

     

    CASSETTE SYSTEMDC inverter 

    CC-GEEI series

    Energyefficiencyclass

    Model ACP-12CC35GEEI ACP-18CC50GEEI ACP-24CC70GEEI ACP-36CC100GEEI ACP-42CC140GEEI ACP-48CC140GEEI ACP-60CC176GEEICapacity Cooling 3500 (900-3900) W 5000 (1600~5800) W 7000 (2400~8500) W 10000 (3200~11000) W 11000 (3300~12500) W 14000 (6000~14800) W 16000 (6500~16500) W

    Heating 3800 (900-4100) W 5500 (1400~6500) W 8000 (2400~9500) W 12000 (2900~14000) W 12500 (3600~15000) W 16000 (5200~18000) W 17000 (5200~20000) WRefrigerant R410A R410A R410A R410A R410A R410A R410AEnergy efficiency class Cooling A A A A A

    Heating A A A A A A

    Energy efficiency EER 2.98 2.86

    COP 3.52 3.61SEER 5.1 5.1 5.1 5.1 5.1 5.1 5.1SCOP 3.8 3.8 3.8 3.8 3.8

    Design load for heating (Pdesignh) 3000 W 4600 W 7200 W 9200 W 9500 W 12000 W 13000 WInput power Cooling 1090 W 1550 W 2180 W 3500 W 3900 W 4600 W 5700 W

    Heating 1050 W 1524 W 2210 W 3550 W 3800 W 4500 W 4700 WAirflow ≤ 550 m3/h ≤ 760 m3/h ≤ 1300 m3/h ≤ 1660 m3/h ≤1660 m3/h ≤2300 m3/h ≤2400 m3/hDehumidifying capacity 1.2 L/h 1.8 L/h 2.4 L/h 3.2 L/h 3.7 L/h 4.5L/h 5.0L/hSound pressure level Indoor unit ≤ 47 dB(A) ≤ 47 dB (A) ≤ 47 dB (A) ≤ 53dB (A) ≤ 54dB (A) ≤ 53dB (A) ≤ 55dB (A)

    Outdoor unit ≤54 dB(A) ≤ 56 dB (A) ≤ 57 dB (A) ≤ 61dB (A) ≤ 61dB (A) ≤ 59dB (A) ≤ 63dB (A)Sound power level Indoor unit ≤ 57 dB ≤ 60 dB ≤ 62 dB ≤ 64 dB ≤ 64 dB ≤ 64dB ≤ 66dB

    Outdoor unit ≤ 62 dB ≤ 64 dB ≤ 65 dB ≤ 68 dB ≤ 70dB ≤ 70dB ≤ 75dBOuter Diameter ofLiquid Pipe

    1/4" 1/4" 3/8" 3/8" 3/8" 3/8 " 3/8"

    Outer Diameter ofGas Pipe

    3/8" 1/2" 5/8" 5/8" 5/8" 5/8 " 3/4"

    Connection wire

    power supply OU: 3*1.5 mm ²;

    power supply IU: 3*1.0 mm ²,connection wire: 2*0.75 mm ²

    power supply OU: 3*1.5 mm ²;

    power supply IU: 3*1.0 mm ²,connection wire: 2*0.75 mm ²

    power supply OU: 3*2.5 mm ²;

    power supply IU: 3*1.0 mm ²,connection wire: 2*0.75 mm ²

    power supply OU: 3*2.5 mm ²;

    power supply IU: 3*1.0 mm ²,connection wire: 2*0.75 mm ²

    power supply OU: 3*5 mm ²;

    power supply IU: 3*1.0 mm ²,connection wire: 2*0.75 mm ²

    power supply OU: 3*5 mm ²;

    power supply IU: 3*1.0 mm ²,connection wire: 2*0.75 mm ²

    power supply OU: 5*2.5 mm ²;

    power supply IU: 3*1.0 mm ²,connection wire: 2*0.75 mm ²

    Power supply ~220-240V/1/50Hz; indoor & outdoor unit~380~415V; 50Hz;3ph; indoor& outdoor unit

    Max. length of pipe 20m 20m 30m 30m 50m 50m 50mMax elevation 15m 15m 15m 15m 30m 30m 30mStandard length 5m 5m 5m 5m 5m 5m 5mAdditional refrigerant 30g/m 30g/m 60g/m 60 g/m 60g/m 60g/m 60g/mWall bracketdistance(outdoor)

    540mm 560mm 610mm 631mm 572mm 572mm 620mm

    Working range -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C

    Net dimensions Indoor unit 596*592*240 596*592*240 840*780*240 840*892*320 840*892*320 910*842*290 mm 910*842*290 mm

    Panel 670*670*65 670*670*65 952*952*65 952*952*65 952*952*65 1040*1040*65 1040*1040*65Outdoor unit 848*320*540 955*396*700 980*427*790 1107*440*1100 958*412*1349 958*412*1349 mm 1085*427*1365 mmNet weight Indoor unit 20 kg 20 kg 26 kg 31 kg 31 kg 43 kg 43 kg

    Panel 3.5 kg 3.5 kg 7 kg 7 kg 7 kg 8 kg 8 kgOutdoor unit 34 kg 47 kg 67 kg 92 kg 95 kg 105 kg 126 kg

    Workable

    with SZC-16

  • 8/9/2019 VIVAX cool 2014.pdf

    20/36

    We reserve the right of eventual printing errors.18

    DUCT SYSTEMDC inverter 

    DT-GEEI series

    Additional wired controler

    8°C heating

    Built-in drain pump (except

    model ACP-60DT176GEEI)Heating operating temperature

    range -15°C

    Low Ambient Cooling Function

    Memory function (auto restart)

    24h timer

    1W standby

    LED display

    Self Diagnosis displaying

    Energyefficiency

    class

    Workablewith SZC-16

    Model ACP-24DT70GEEI ACP-36DT100GEEI ACP-42DT140GEEI ACP-48DT140GEEI ACP-60DT176GEEI

    Capacity Cooling 7000 (2400~8500) W 10000( 3200~11000) W 11500 (3600~13000) W 14000 (6000~14500) W 16000 (6800~17500) W

    Heating 8000 (2400~9500) W 12000 (2900~14000) W 13500 (3900~15000) W 15500 (5200~17000) W 16500 (5300~18800) W

    Refrigerant R410A R410A R410A R410A R410A

    Energy efficiency class Cooling A A A C C

    Heating A A A B A

    Energy efficiency EER 2.98 2.86

    COP 3.52 3.61

    SEER 5.1 5.1 5.1 - -SCOP 3.8 3.8 3.8 - -

    Design load for heating (Pdesignh) 7200 W 10400 W 10000 W 11800 W 13000 W

    Input power Cooling 2180 W 3500 W 4000 W 4700 W 5600 W

    Heating 2210 W 3500 W 3900 W 4400 W 4570 W

    Airflow ≤1400 m3/h ≤2000 m3/h ≤2300 m3/h ≤2400 m3/h ≤3000 m3/h

    Dehumidifying capacity 2.0 L/h 2.8 L/h 3.2 L/h 4.5 L/h 5.0 L/h

    Sound pressure level Indoor unit ≤ 47dB (A) ≤ 53 dB (A) ≤ 53dB (A) ≤ 55 dB (A) ≤ 57 dB (A)

    Outdoor unit ≤ 57dB (A) ≤ 61dB (A) ≤ 61dB (A) ≤ 59 dB (A) ≤ 63 dB (A)

    Sound power level Indoor unit ≤ 64 dB ≤ 64 dB ≤ 64 dB ≤ 68 dB ≤ 71 dB

    Outdoor unit ≤ 65 dB ≤ 68 dB ≤ 70 dB ≤ 70 dB ≤ 75 dB

    Outer Diameter of Liquid Pipe 3/8" 3/8" 3/8" 3/8" 3/8"

    Outer Diameter of Gas Pipe 5/8" 5/8" 5/8" 5/8" 3/4"

    Connection wirepower supply OU: 3*1.5 mm ²;power supply IU: 3*1.0 mm ²,wire: 2*0.75 mm ²

    power supply OU: 3*2.5 mm ²;power supply IU: 3*1.0 mm ²,wire: 2*0.75 mm ²

    power supply OU: 3*2.5 mm ²;power supply IU: 3*1.0 mm ²,wire: 2*0.75 mm ²

    power supply OU: 3*2.5 mm ²;power supply IU: 3*1.0 mm ²,wire: 2*0.75 mm ²

    power supply OU: 5*2.5 mm ²;power supply IU: 3*1.0 mm ²,wire: 2*0.75 mm ²

    Power supply ~220-240V/1/50Hz; indoor & outdoor unit~380~415V; 50Hz;3ph;indoor & outdoor unit

    Max. length of pipe 30 m 30 m 50 m 50 m 50 m

    Max elevation 15 m 15 m 30 m 30 m 30 m

    Standard length 5 m 5 m 5 m 5 m 5 m

    Additional refrigerant 60 g/m 60 g/m 60 g/m 60 g/m 60 g/m

    Wall bracket distance(outdoor) 610 mm 631 mm 572 mm 572 mm 620 mm

    Working range -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C

    Net dimensions Indoor unit 1239*558*268 mm 1226*775*290 mm 1226*775*290 mm 1340*750*350 mm 1340*750*350 mmOutdoor unit 980*427*790 mm 1107*440*1100 mm 958*412*1349 mm 958*412*1349 mm 1085*427*1365 mm

    Net weight Indoor unit 34 kg 46 kg 46 kg 56 kg 57 kg

    Outdoor unit 68 kg 92 kg 95 kg 105 kg 126 kg

  • 8/9/2019 VIVAX cool 2014.pdf

    21/36

    We reserve the right of eventual printing errors.19

    8°C HeatingMaintain the room temperature steadily at 8°C and prevent the room from

    freezing by heating operation when nobody is at home for long in severe winter.

     -15°C CoolingCooling at -15°C while keep a reliable operation. As the outdoor temperature

    changes, the frequency of compressor and the speed of fan adjustus accordingly.

    -15°C Heating

    Operate finely when heating at -15°C. It is supported by VIVAX’s electricalheating chassis, preheating technology and frequency-adjusting compressor.

    Funtions for Low Ambient Temperature

    Outdoor units -CC-GEEI/CF-GEEI/DT-GEEI series :

    Model ACP-12CC35GEEI ACP-18CC50GEEIACP-18CF50GEEI

    ACP-24CF70GEEIACP-24CC70GEEIACP-24DT70GEEI

    ACP-36CF100GEEIACP-36CC100GEEIACP-36DT100GEEI

    ACP-42CC140GEEIACP-42DT140GEEIACP-48CF140GEEIACP-48CC140GEEIACP-48DT140GEEI

    ACP-60CF176GEEIACP-60CC176GEEIACP-60DT176GEEI

    Netdimensions 848*320*540 955*396*700 980*427*790 mm 1107*440*1100 mm 958*412*1349 mm 1085*427*1365 mm

    Net weight 34 47 68 kg 92 kg 105 kg 126 kg

    Wall bracketdistance 540 mm 560 mm 610 mm 631 mm 572 mm 620mm

    Power supply ~220-240V/1/50Hz; indoor & outdoor unit ~380~415V; 50Hz;3ph;indoor & outdoor unit

    1W STANDBY

  • 8/9/2019 VIVAX cool 2014.pdf

    22/36

    We reserve the right of eventual printing errors.20

    LOW AMBIENT COOLING KIT

    Allows operation of the unit in cooling modeat low outdoor temperature.

    DUAL SPLIT SYSTEM with two indoor unitsMulti system

    AEEI series

    Model ACP-18COFM50AEEI ACP-09CIFM25AEEI

    Capacity Cooling 5274(2051~5274) W 2600 W

    Heating 5860(2344~6153) W 2800 WRefrigerant R410 R410AEnergy efficiency class Cooling A

    Heating A+

    Energy Efficiency SEER 5.2SCOP 4.1

    Design load for heating (Pdesignh) 5391 WInput power Cooling 1600 W

    Heating 1700 WAirflow ≤500 m³/hDehumidifying capacity 0.8 L/hSound pressure level Indoor unit ≤40 dB(A)

    Outdoor unit ≤61 dB(A)Sound power level Indoor unit ≤55 dB

    Outdoor unit ≤63 dBOuter Diameter of Liquid Pipe 1/4" 1/4"Outer Diameter of Gas Pipe 3/8" 3/8"Connection wire 4*1.0 mm ² 4*1.0 mm ²Power supply ~220-240V/1/50Hz; outdoor unitMax. length of pipe 20 mMax elevation 10 mStandard length 5 mAdditional refrigerant 15 g/mWall bracket distance(outdoor) 560 mmWorking range -15°C≤T≤50°C -15°C≤T≤50°C

    Net dimensions Indoor unit 710x190x250 mmOutdoor unit 845x320x700 mmNet weight Indoor unit 6.5 kg

    Outdoor unit 48 kgACP-18COFM50AEEI

    Energyefficiencyclass

    ACP-09CIFM25AEEII Feel (follow me)

    Ionizer

    24h timerActive carbon filter

    Auto restart (memory function)

    Sleep mode

    Auto Swing

    Dust filtar

    LED display

    Self Diagnosis displaying

    ACP-18COFM50AEEIAuto restart (memory function)

    Condenser and compressor’s heatersLow voltage start up

    Heating operating temperature

    range -15°C

    Cooling operating temperature

    range -15°C

    Soft Start

    Self Diagnosis displaying

    I FEEL (follow me)

     The mini sensor in the remote controller

    can sense its surrounding temperature, and

    transmit the signal back to the indoor unit.

    So, the unit can adjust the air flow volume

    and temperature accordingly so as to

    provide maximum comfort.

    d l ACP CIFM AEEI

  • 8/9/2019 VIVAX cool 2014.pdf

    23/36

    We reserve the right of eventual printing errors.21

    model: ACP-09CIFM25AEEI

    MULTI SPLIT SYSTEM

  • 8/9/2019 VIVAX cool 2014.pdf

    24/36

    We reserve the right of eventual printing errors.22

    I feel

    Ionizer

    1W standby

    Memory function (auto restart)Dry Mould Proof 

     Turbo mode

    24h timer

    Sleep mode

    LED display

    Self Diagnosis displaying

    MULTI SPLIT SYSTEMwall mounted indoor unit - DC inverter 

    CIFM-GEEI series

    Energy

    efficiencyclass

    IONIZERAnions are taking care of your body by stimulating circulation,improvement of your lungs capacity and preventing airway diseases

    (e.g. asthma). Negative ions are eliminating dust and smoke, when

    air circulates through the ionizer, anions automatically start to act.

     The amount of anions can reach maximum of 1.000.000 cm3. Anions

    are removing chemical gases and dust particles.

    Model ACP-12CIFM35GEEI ACP-18CIFM50GEEI

    Capacity Cooling 3500 W 5300 WHeating 3800 W 5800 W

    Refrigerant R410A R410A

    Airflow ≤630 m³/h ≤850 m³/h

    Dehumidifying capacity 1.4 L/h 1.8 L/h

    Sound pressure level Indoor unit ≤42 dB(A) ≤45 dB(A)

    Sound power level Indoor unit ≤57 dB ≤60 dB

    Outer Diameter of Liquid Pipe 1/4” 1/4”

    Outer Diameter of Gas Pipe 3/8” 1/2”

    Connection wire 4*0.75 mm² 4*0.75 mm²

    Power supply ~220-240V/1/50Hz; outdoor unit

    Net dimensions Indoor unit 848x189x274 mm 945x298x208 mm

    Net weight Indoor unit 10.0 kg 13.0 kg

    Model ACP-07CIFM21GEEI ACP-09CIFM25GEEI

    Capacity Cooling 2100 W 2600 W

    Heating 2600 W 2800 W

    Refrigerant R410A R410A

    Airflow ≤500 m³/h ≤500 m³/h

    Dehumidifying capacity 0.6 L/h 0.8 L/h

    Sound pressure level Indoor unit ≤40 dB(A) ≤40 dB(A)Sound power level Indoor unit ≤55 dB ≤55 dB

    Outer Diameter of Liquid Pipe 1/4” 1/4”

    Outer Diameter of Gas Pipe 3/8” 3/8”

    Connection wire 4*0.75 mm ² 4*0.75 mm ²

    Power supply ~220-240V/1/50Hz; outdoor unit

    Net dimensions Indoor unit 794x186x265 mm 794x186x265 mm

    Net weight Indoor unit 9.0 kg 9.0 kg

    I FEEL (follow me)

     The mini sensor in the remote controller

    can sense its surrounding temperature, and

    transmit the signal back to the indoor unit.

    So, the unit can adjust the air flow volume

    and temperature accordingly so as to

    provide maximum comfort.

    1W STANDBY

    model: ACP 09CIFM25GEEI

  • 8/9/2019 VIVAX cool 2014.pdf

    25/36

    We reserve the right of eventual printing errors.23

    model: ACP-09CIFM25GEEI

    CTIFM GEEI iMULTI SPLIT SYSTEM

  • 8/9/2019 VIVAX cool 2014.pdf

    26/36

    We reserve the right of eventual printing errors.24

    CTIFM-GEEI seriesMULTI SPLIT SYSTEMfloor mounted indoor unit - DC inverter 

    I feel

    1W standby

    Memory function (auto restart)Dry Mould Proof

     Turbo mode

    24h timer

    Sleep mode

    LED display

    Self Diagnosis displaying

     

    Energyefficiencyclass

    DRY MOULD PROOF

     The fan remains to work after turning off the

    device in order to dry up the moisture that

    remains in the indoor unit.

    Model ACP-09CTIFM25GEEI ACP-12CTIFM35GEEI ACP-18CTIFM50GEEI

    Capacity Cooling 2600 W 3500 W 5300 W

    Heating 2800 W 3800 W 5800 W

    Refrigerant R410A R410A R410A

    Airflow 480 m ³/h 550 m ³/h 650 m ³/h

    Dehumidifying capacity 0.8 L/h 1.4 L/h 1.8 L/hSound pressure level Indoor unit ≤42 dB(A) ≤42 dB(A) ≤48 dB(A)

    Sound power level Indoor unit ≤50 dB ≤52 dB ≤58 dB

    Outer Diameter of Liquid Pipe 1/4" 1/4" 1/4"

    Outer Diameter of Gas Pipe 3/8" 3/8" 1/2"

    Connection wire 4*1.0 mm ² 4*1.0 mm ² 4*1.0 mm ²

    Power supply ~220-240V/1/50Hz; outdoor unit

    Net dimensions Indoor unit 700x600x215 mm 700x600x215 mm 700x600x215 mm

    Net weight Indoor unit 15 kg 15 kg 15 kg

    I FEEL (follow me)

     The mini sensor in the remote controller

    can sense its surrounding temperature, and

    transmit the signal back to the indoor unit.

    So, the unit can adjust the air flow volume

    and temperature accordingly so as to

    provide maximum comfort.

    model: ACP-18CTIFM50GEEI 

  • 8/9/2019 VIVAX cool 2014.pdf

    27/36

    We reserve the right of eventual printing errors.25

    MULTI SPLIT SYSTEM CCIFM-GEEI series

  • 8/9/2019 VIVAX cool 2014.pdf

    28/36

    We reserve the right of eventual printing errors.26

    MULTI SPLIT SYSTEMcassette indoor unit - DC inverter 

    Additional wired controler

    I feel

    1W standbyBuilt-in drain pump

    Memory function

    (auto restart)

     Turbo mode24h timer

    Sleep mode

    LED display

    Self Diagnosis displaying

     

    Energyefficiencyclass

    CCIFM GEEI series

    Workable

    with SZC-16

    Model ACP-12CCIFM35GEEI ACP-18CCIFM50GEEI

    Capacity Cooling 3500 W 4500 W

    Heating 4000 W 5000 W

    Refrigerant R410A R410A

    Airflow ≤600 m³/h ≤600 m³/h

    Dehumidifying capacity 1.4 L/h 1.8 L/h

    Sound pressure level Indoor unit ≤46 dB(A) ≤46 dB(A)

    Sound power level Indoor unit ≤56 dB ≤56 dBOuter Diameter of Liquid Pipe 1/4" 1/4"

    Outer Diameter of Gas Pipe 3/8" 1/2"

    Connection wire 4*1.0 mm ² 4*1.0 mm ²

    Power supply ~220-240V/1/50Hz; outdoor unit

    Net dimensions Indoor unit 570x570x230 mm 570x570x230 mm

    Panel 650x650x50 mm 650x650x50 mm

    Net weight Indoor unit 18 kg 18 kg

    Panel 2.5 kg 2.5 kg

    I FEEL (follow me)

     The mini sensor in the remote controller

    can sense its surrounding temperature, and

    transmit the signal back to the indoor unit.

    So, the unit can adjust the air flow volume

    and temperature accordingly so as to

    provide maximum comfort.

    TURBO MODE

    With this function, the air conditioner will

    maximize the output of cooling or heating

    capacity, make the room cool down or

    heat up rapidly, and attain the desired

    temperature in the shortest time.

    MULTI SPLIT SYSTEM DTIFM-GEEI series

  • 8/9/2019 VIVAX cool 2014.pdf

    29/36

    We reserve the right of eventual printing errors.27

    MULTI SPLIT SYSTEM duct indoor units - DC inverter 

    Additional wired controler

    I feel

    1W standbyBuilt-in drain pump

    Memory function

    (auto restart)

     Turbo mode24h timer

    Sleep mode

    LED display

    Self Diagnosis displaying

     

    Energyefficiencyclass

    DTIFM GEEI series

    Workable

    with SZC-16

    Model ACP-18DTIFM50GEEI ACP-24DTIFM70GEEI

    Capacity Cooling 5000 W 7100 W

    Heating 5500 W 8000 W

    Refrigerant R410A R410A

    Airflow ≤700 m³/h ≤1000 m³/h

    Dehumidifying capacity 1.8 L/h 2.5 L/h

    Sound pressure level Indoor unit ≤41 dB(A) ≤42 dB(A)Sound power level Indoor unit ≤50 dB ≤52 dB

    Outer Diameter of Liquid Pipe 1/4" 3/8"

    Outer Diameter of Gas Pipe 1/2" 5/8"

    Connection wire 4*1.0 mm ² 4*1.0 mm ²

    Power supply ~220-240V/1/50Hz; outdoor unit

    Net dimensions Indoor unit 900x200x615 mm 1100x200x615 mm

    Net weight Indoor unit 27 kg 31 kg

    I FEEL (follow me)

     The mini sensor in the remote controller

    can sense its surrounding temperature, and

    transmit the signal back to the indoor unit.

    So, the unit can adjust the air flow volume

    and temperature accordingly so as to

    provide maximum comfort.

    TURBO MODE

    With this function, the air conditioner will

    maximize the output of cooling or heating

    capacity, make the room cool down or

    heat up rapidly, and attain the desired

    temperature in the shortest time.

    MULTI SPLIT SYSTEM COFM-GEEI series

  • 8/9/2019 VIVAX cool 2014.pdf

    30/36

    We reserve the right of eventual printing errors.28

    MULTI SPLIT SYSTEM outdoor unit - DC inverter 

    Heating operating temperature

    range -15°C

    Cooling operating temperature

    range -15°C (18/24/28COFM) - LACfunction

    Cooling operating temperature

    range -5°C (41COFM) - LAC

    functionCompressor With Electric Heater

    (all models)

    Chassis With Electric Heater

    (models 18/24/28COFM)

    Memory function (auto restart)

    Automatic Defrosting

     

    ACP-18COFM50GEEI ACP-24COFM70GEEI

    ACP-28COFM80GEEI

    ACP-41COFM121GEEI

    Energyefficiencyclass

    LOW AMBIENT

    COOLING KIT

    Allows operation of the

    unit in cooling mode at low

    outdoor temperature.

    Model ACP-18COFM50GEEI ACP-24COFM70GEEI ACP-28COFM80GEEI ACP-41COFM121GEEI

    Capacity Cooling 5000(2050~6200) W 7100(2200~10000) W 8000(2200~10000) W 12100(2100~13600) WHeating 5600(2500~6650) W 8500(3600~11000) W 9300(2800~11000) W 13000(2600~14000) W

    Refrigerant R410A R410A R410A R410A

    Energy efficiency class Cooling A+ A A AHeating A A A A

    Energy Efficiency EER 3.37COP 3.66SEER 5.6 5.1 5.1SCOP 3.8 3.8 3.8

    Design load for heating (Pdesignh) 4600 W 7000 W 7000 WMaximum number of indoor units 2 3 4 5Input power Cooling 1550 W 2400 W 2490 W 3590 W

    Heating 1550 W 2350 W 2580 W 3545 WOutdoor unit ≤56 dB(A) ≤58 dB(A) ≤58 dB(A) ≤54 dB(A)

    Outdoor unit ≤63 dB ≤68 dB ≤68 dB ≤64 dBOuter Diameter of Liquid Pipe 1/4" 1/4" 1/4" 4*1/4"+3/8"Outer Diameter of Gas Pipe 3/8" 3/8" 3/8" 2*3/8"+2*1/2"+5/8"Connection wire 3*2.5 mm² 3*2.5 mm² 3*2.5 mm² 3*4.0 mm²Power supply ~220-240V/1/50Hz; outdoor unitMax. length of pipe 20 m 60 m 70 m 80 mMax elevation 10 m 20 m 20 m 25 mStandard length 5 m 5 m 5 m 50 mAdditional refrigerant 20 g/m 20 g/m 20 g/m 22 g/mWall bracket distance(outdoor) 550 mm 560 mm 560 mm 631 mmWorking range -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C

    Net dimensions Outdoor unit 955x396x700 mm 980x427x790 mm 980x427x790 mm 1015x440x1100 mmNet weight Outdoor unit 50 kg 69 kg 69 kg 102 kg

     

    COFM GEEI series

    Multi split system - combination

  • 8/9/2019 VIVAX cool 2014.pdf

    31/36

    We reserve the right of eventual printing errors.29

    Multi split system combination

         2     i    n     d    o    o    r    u    n     i    t

    2,1 + 2,12,1 + 2,62,1 + 3,52,6 + 2,62,6 + 3,53,5 + 3,5

    2,05 2,05 - - 4,1(2,05-4,7)2,30 2,50 - - 4,8(2,05-5,8)2,00 3,50 - - 5,5(2,15-6,3)2,50 2,50 - - 5,0(2,05-6,2)2,50 3,50 - - 6,0(2,15-6,3)3,00 3,00 - - 6,0(2,1-6,2)

    A B C D Total

    COOLING [kW]

    2,25 2,25 - - 4,5(2,5-6,0)2,45 2,75 - - 5,2(2,5-6,6)2,30 3,80 - - 6,1(2,6-6,65)2,80 2,80 - - 5,6(2,5-6,6)2,80 3,80 - - 6,3(2,6-6,65)3,15 3,15 - - 6,3(2,5-6,6 5)

    A B C D Total

    HEATING [kW]

    ACP-18COFM50GEEIUnit

    2,90 2,90 - - - 4,8(4,5-8,8)2,90 3,10 - - - 6,0(4,5-8,8)2,90 4,40 - - - 7,3(4,5-8,8)3,15 3,15 - - - 6,3(4,5-8,8 )3,15 4,35 - - - 7,5(4,5-8,8)3,75 3,75 - - - 7,5(4,5-8,8)2,75 6,15 - - - 8,9(4,5-9,9)3,85 6,15 - - - 10,0(4,5-11,0)5,90 5,90 - - - 11,8(4,5-12,5)

    2,80 2,80 2,80 - - 8,4(4,5-12,0)2,80 2,80 3,10 - - 8,7(4,5-12,0)2,70 3,00 3,00 - - 8,7(4,5-12,0)2,50 2,50 3,80 - - 8,8(4,5-12,0 )3,00 3,00 3,00 - - 9,0(4,5-12,0)

    2,50 2,70 3,70 - - 8,9(4,5-12,0)2,60 2,60 3,70 - - 8,9(4,5-12,0)2,90 2,90 6,00 - - 11,8(4,5-12 ,5)2,60 4,10 4,10 - - 10,8(4,5-11,0)3,10 3,90 3,90 - - 10,9(4,5-11,0)3,15 4,00 5,85 - - 13,0(4,5-13,2)2,40 5,00 5,00 - - 12,4(4,5-14,0)4,30 4,30 4,30 - - 12,9(4,5-14,0)4,00 4,00 5,00 - - 13,0(4,5-14,0)3,14 4,94 4,94 - - 13,0(4,5-14,0)4,34 4,34 4,34 - - 13,0(4,5-14,0)

    2,65 2,65 2,65 2,65 - 10,6(4,5-12,0)2,60 2,60 2,60 2,90 - 10,7(4,5-12,0)2,50 2,50 2,90 2,90 - 10,8(4,5-12,0)2,60 2,60 2,60 4,00 - 11,8(4,5-12,5)2,80 3,00 3,00 3,00 - 11,8(4,5-14,0)2,50 2,50 2,90 4,00 - 11,9(4,5-14,0)3,25 3,25 3,25 3,25 - 13,0(4,5-14,0)2,50 2,75 2,75 3,90 - 11,9(4,5-14,0)2,50 2,50 4,00 4,00 - 13,0(4,5-14,0)3,00 3,00 3,00 4,00 - 13,0(4,5-14,0)2,55 2,55 2,55 5,35 - 13,0(4,5-14,0)2,60 2,75 2,75 3,80 - 11,9(4,5-14,0)2,65 2,65 3,85 3,85 - 13,0(4,5-14,0)2,25 2,25 3,45 5,05 - 13,0(4,5-14,0)2,10 2,10 4,40 4,40 - 13,0(4,5-14,0)2,35 3,55 3,55 3,55 - 13,0(4,5-14,0)2,65 3,45 3,45 3,45 - 13,0(4,5-14,0)2,35 2,85 2,85 4,95 - 13,0(4,5-14,0)2,10 2,70 4,10 4,10 - 13,0(4,5-14,0)3,25 3,25 3,25 3,25 - 13,0(4,5-14,0)2,70 2,70 2,70 4,90 - 13,0(4,5-14,0)2,55 2,55 3,95 3,95 - 13,0(4,5-14,0)

    2,60 2,60 2,60 2,60 2,60 13,0(4,5-14,0)2,55 2,55 2,55 2,55 2,80 13,0(4,5-14,0)2,50 2,50 2,50 2,75 2,75 13,0(4,5-14,0)2,35 2,35 2,75 2,75 2,75 13,0(4,5-14,0)

    2,59 2,59 2,59 2,59 2,59 13,0(4,5-14,0)2,40 2,40 2,40 2,40 3,40 13,0(4,5-14,0)2,21 2,21 2,21 3,16 3,16 13,0(4,5-14,0)2,06 2,06 2,96 2,96 2,96 13,0(4,5-14,0)1,96 2,76 2,76 2,76 2,76 13,0(4,5-14,0)2,60 2,60 2,60 2,60 2,60 13,0(4,5-14,0)2,41 2,41 2,41 2,41 3,36 13,0(4,5-14,0)2,36 2,36 2,36 2,94 2,94 13,0(4,5-14,0)2,06 2,06 2,94 2,94 2,94 13,0(4,5-14,0)2,16 2,71 2,71 2,71 2,71 13,0(4,5-14,0)2,60 2,60 2,60 2,60 2,60 13,0(4,5-14,0)2,26 2,26 2,26 2,26 3,96 13,0(4,5-14,0)2,06 2,06 2,06 3,36 3,36 13,0(4,5-14,0)2,11 2,11 2,11 2,76 3,91 13,0(4,5-14,0)2,10 2,10 2,10 3,45 3,45 13,0(4,5-14,0)1,96 1,96 2,61 2,61 3,86 13,0(4,5-14,0)2,06 2,46 2,46 2,46 3,56 13,0(4,5-14,0)

    A B C D E Total

    2,30 2,30 - - - 4,6(3,5-8,0)2,30 2,50 - - - 4,8(3,5-8,0)2,30 3,50 - - - 5,8(3,5-8,0)2,50 2,50 - - - 5,5(3,5-8,0)2,50 3,50 - - - 6,0(3,5-9,0)3,50 3,50 - - - 7,0(3,5-9,0)2,20 4,90 - - - 7,1(3,5-9,0)3,10 4,90 - - - 8,0(3,5-9,0)4,75 4,75 - - - 9,5(3,5-11,0)

    2,30 2,30 2,30 - - 6,9(3,5-9,0 )2,25 2,25 2,50 - - 7,0(3,5-9,0)2,20 2,45 2,45 - - 7,1(3,5-9,0)2,00 2,00 3,10 - - 7,1(3,5-9,0)2,40 2,40 2,40 - - 7,2(3,5-9,0)

    2,00 2,10 3,00 - - 7,1(3,5-9,0)2,15 2,15 3,00 - - 7,3(3,5-9,0)2,35 2,35 4,80 - - 9,5(3,5-11,0)2,10 3,30 3,30 - - 8,7(3,5-9,6)2,50 3,10 3,10 - - 8,7(3,5-9,6 )2,50 3,20 4,70 - - 10,4(3,5-12 ,2)2,10 4,40 4,40 - - 11,6(3,5-13 ,6)3,50 3,50 3,50 - - 10,5(3,5-12 ,2)3,20 3,20 4,00 - - 10,4(3,5-12 ,2)2,80 4,40 4,40 - - 11,6(3,5-13,6)3,90 3,90 3,90 - - 11,7(3,5-13,6)

    2,15 2,15 2,15 2,15 - 8,6(3,5-9,6)2,10 2,10 2,10 2,30 - 8,6(3,5-9,6)2,00 2,00 2,30 2,30 - 8,6(3,5-9,6)2,10 2,10 2,10 3,20 - 9,5(3,5-11,0)2,30 2,40 2,40 2,40 - 9,5(3,5-11,0)2,00 2,00 2,30 3,20 - 9,5(3,5-11,0)2,60 2,60 2,60 2,60 - 10,4(3,5-12,2)2,00 2,20 2,20 3,10 - 9,5(3,5-11,0)2,00 2,00 3,20 3,20 - 10,4(3,5-12,2)2,40 2,40 2,40 3,20 - 10,4(3,5-12,2)2,30 2,30 2,30 4,70 - 11,6(3,5-13,6)2,00 2,20 2,20 3,10 - 9,5(3,5-11,0)2,10 2,10 3,10 3,10 - 10,4(3,5-12,2)2,00 2,00 3,10 4,50 - 11,6(3,5-13,6)1,90 1,90 3,90 3,90 - 11,6(3,5-13,6)2,00 3,20 3,20 3,20 - 11,6(3,5-13,6)2,30 3,10 3,10 3,10 - 11,6(3,5-13,6)2,10 2,55 2,55 4,40 - 11,6(3,5-13,6)1,90 2,40 3,65 3,65 - 11,6(3,5-13,6)2,90 2,90 2,90 2,90 - 11,6(3,5-13,6)2,45 2,45 2,45 4,25 - 11,6(3,5-13,6)2,30 2,30 3,50 3,50 - 11,6(3,5-13,6)

    2,08 2,08 2,08 2,08 2,08 10,4(3,5-12,2)2,05 2,05 2,05 2,05 2,20 10,4(3,5-12,2)2,00 2,00 2,00 2,20 2,20 10,4(3,5-12,2)1,90 1,90 2,20 2,20 2,20 10,4(3,5-12,2)

    2,30 2,45 2,45 2,45 2,45 12,1(3,5-13,6)1,95 1,95 1,95 1,95 2,60 10,4(3,5-12,2)2,10 2,10 2,10 2,90 2,90 12,1(3,5-13,6)2,00 2,00 2,70 2,70 2,70 12,1(3,5-13,6)1,90 2,55 2,55 2,55 2,55 12,1(3,5-13,6)2,42 2,42 2,42 2,42 2,42 12,1(3,5-13,6)2,25 2,25 2,25 2,25 3,10 12,1(3,5-13,6)2,20 2,20 2,20 2,75 2,75 12,1(3,5-13,6)2,00 2,00 2,70 2,70 2,70 12,1(3,5-13,6)2,10 2,50 2,50 2,50 2,50 12,1(3,5-13,6)2,42 2,42 2,42 2,42 2,42 12,1(3,5-13,6)2,10 2,10 2,10 2,10 3,70 12,1(3,5-13,6)2,00 2,00 2,00 3,05 3,05 12,1(3,5-13,6)2,00 2,00 2,00 2,55 3,55 12,1(3,5-13,6)2,00 2,00 2,00 3,05 3,05 12,1(3,5-13,6)1,85 1,85 2,45 2,45 3,50 12,1(3,5-13,6)1,85 2,35 2,35 2,35 3,20 12,1(3,5-13,6)

    A B C D E Total

         2     i    n     d    o    o    r    u    n     i    t

         3     i    n     d    o    o    r    u    n     i    t

         4     i    n     d    o    o    r    u    n     i    t

    2,1 + 2,12,1 + 2,62,1 + 3,52,6 + 2,62,6 + 3,53,5 + 3,52,6 + 5,03,5 + 5,05,0 + 5,0 2,1+ 2,1 + 2,12,1 + 2,1 + 2,62,1 + 2,6 + 2,62,1 + 2,1 + 3,52,6 + 2,6 + 2,6

    2,1 + 2,6 + 3,52,6 + 2,6 + 3,52,6 + 2,6 + 5,02,1 + 3,5 + 3,52,6 + 3,5 + 3,52,6 + 3,5 + 5,02,6 + 5,0 + 5,03,5 + 3,5 + 3,53,5 + 3,5 + 5,03,5 + 5,0 + 5,0

    5,0 + 5,0 + 5,0

    2,1 + 2,1 + 2,1 + 2,12,1 + 2,1 + 2,1 + 2,62,1 + 2,1 + 2,6 + 2,62,1 + 2,1 + 2,1 + 3,52,1 + 2,6 + 2,6 + 2,62,1 + 2,1 + 2,6 + 3,52,6 + 2,6 + 2,6 + 2,6

    2,1 + 2,6 + 2,6 + 3,52,1 + 2,1 + 3,5 + 3,52,6 + 2,6 + 2,6 + 3,52,6 + 2,6 + 2,6 + 5,02,1 + 2,6 + 3,5 + 3,52,6 + 2,6 + 3,5 + 3,52,6 + 2,6 + 3,5 + 5,02,6 + 2,6 + 5,0 + 5,02,1 + 3,5 + 3,5 + 3,52,6 + 3,5 + 3,5 + 3,52,6 + 3,5 + 3,5 + 5,02,6 + 3,5 + 5,0 + 5,03,5 + 3,5 + 3,5 + 3,53,5 + 3,5 + 3,5 + 5,03,5 + 3,5 + 5,0 + 5,0

    2,1 + 2,1 + 2,1 + 2,1 + 2,12,1 + 2,1 + 2,1 + 2,1 + 2,62,1 + 2,1 + 2,1 + 2,6 + 2,62,1 + 2,1 + 2,6 + 2,6 + 2,6

    2,1 + 2,6 + 2,6 + 2,6 + 2,62,1 + 2,1 + 2,1 + 2,1 + 3,52,1 + 2,1 + 2,1 + 3,5 + 3,52,1 + 2,1 + 3,5 + 3,5 + 3,52,1 + 3,5 + 3,5 + 3,5 + 3,52,6 + 2,6 + 2,6 + 2,6 + 2,62,6 + 2,6 + 2,6 + 2,6 + 3,52,6 + 2,6 + 2,6 + 3,5 + 3,52,6 + 2,6 + 3,5 + 3,5 + 3,52,6 + 3,5 + 3,5 + 3,5 + 3,53,5 + 3,5 + 3,5 + 3,5 + 3,52,6 + 2,6 + 2,6 + 2,6 + 5,02,6 + 2,6 + 2,6 + 5,0 + 5,02,6 + 2,6 + 2,6 + 3,5 + 5,02,6 + 2,6 + 2,6 + 5,0 + 5,02,6 + 2,6 + 3,5 + 3,5 + 5,02,6 + 3,5 + 3,5 + 3,5 + 5,0

    COOLING [kW] HEATING [kW]

    ACP-41COFM121GEEIUnit

         5     i    n     d    o    o    r    u    n     i    t

        2 

        i   n    d   o   o   r   u

       n    i    t

    2,1 + 2,12,1 + 2,6

    2,1 + 3,52,6 + 2,62,6 + 3,53,5 + 3,52,1 + 5,02,6 + 5,0

    2,1+ 2,1 + 2,12,1 + 2,1 + 2,62,1 + 2,6 + 2,62,1 + 2,1 + 3,52,6 + 2,6 + 2,62,1 + 2,6 + 3,52,6 + 2,6 + 3,52,1 + 3,5 + 3,52,6 + 3,5 + 3,53,5 + 3,5 +3,5

    2,30 2,30 - - 4,6(2,3-7,8)2,30 2,50 - - 4,8(2,3-7,8)

    2,20 3,60 - - 5,8(2,1-8,0)2,50 2,50 - - 5,0(2,0-7,8)2,60 3,60 - - 6,2(2,1-8,0)3,50 3,50 - - 7,0(2,2-8,2)2,00 5,00 - - 7,0(2,2-8,2)2,30 4,70 - - 7,0(2,3-8,2)

    2,30 2,30 2,30 - 6,9(2,2-9,0)2,25 2,25 2,50 - 7,0(2,2-9,2)2,20 2,45 2,45 - 7,1(2,2-9,4)2,00 2,00 3,10 - 7,1(2,2-9,4)2,36 2,36 2,36 - 7,1(2,2-9,5)2,00 2,15 2,95 - 7,1(2,2-9,5)2,10 2,10 2,90 - 7,1(2,2-9,5)1,90 2,60 2,60 - 7,1(2,2-9,6)1,90 2,60 2,60 - 7,1(2,2-9,6)2,36 2,36 2,36 - 7,1(2,2-9,6)

     A B C D Total

    3,00 3,00 - - 6,0(3,0-8,0)3,00 3,20 - - 6,2(2,5-8,5)

    3,00 4,00 - - 7,0(3,4-9,0)3,20 3,20 - - 6,4(3,2-8,5)3,20 4,00 - - 7,2(3,5-9,3)3,85 3,85 - - 7,7(3,5-9,5)2,20 5,50 - - 7,7(3,6-9,6)2,60 5,10 - - 7,7(3,7-9,9)

    2,70 2,70 2,70 - 8,1(3,5-9,9)2,50 2,50 3,10 - 8,1(3,5-9,9)2,40 3,05 3,05 - 8,5(3,6-9,9)2,30 2,30 3,90 - 8,5(3,7-9,9)2,85 2,85 2,85 - 8,5(3,7-9,9)2,10 2,75 3,65 - 8,5(3,7-9,9)2,55 2,55 3,40 - 8,5(3,8-9,9)2,00 3,25 3,25 - 8,5(3,8-9,9)2,20 3,05 3,05 - 8,5(3,8-9,9)2,85 2,85 2,85 - 8,5(3,8-9,9)

     A B C D Total

    ACP-24COFM70GEEI

    Unit

         3     i    n     d    o    o    r    u    n     i    t

        2 

        i   n    d   o   o   r   u   n    i    t 2,1 + 2,1

    2,6 + 3,53,5 + 3,52,6 + 5,03,5 + 5,05,0 + 5,0

    2,1+ 2,1 + 2,12,1 + 2,1 + 2,62,1 + 2,6 + 2,62,6 + 2,6 + 2,62,6 + 2,6 + 3,52,6 + 3,5 + 3,53,5 + 3,5 + 3,52,6 + 2,6 + 5,0

    2,6 + 3,5 + 5,03,5 + 5,0 + 5,0

    2,1 + 2,1 + 2,1 + 2,12,1 + 2,1 + 2,1 + 2,62,1 + 2,1 + 2,6 + 2,62,1 + 2,1 + 2,1 + 3,52,1 + 2,6 + 2,6 + 2,62,1 + 2,1 + 2,6 + 3,52,6 + 2,6 + 2,6 + 2,62,1 + 2,6 + 2,6 + 3,52,1 + 2,1 + 3,5 + 3,52,6 + 2,6 + 2,6 + 3,52,1 + 2,6 + 3,5 + 3,52,6 + 2,6 + 3,5 + 3,52,1 + 3,5 + 3,5 + 3,52,6 + 3,5 + 3,5 + 3,5

    2,50 2,50 - - 5,0(2,2-6,7)2,50 3,50 - - 6,0(2,2-7,8)3,50 3,50 - - 7,0(2,7-8,2)2,60 4,50 - - 7,1(2,7-9,5)3,10 4,00 - - 7,1(2,7-9,5)3,60 3,60 - - 7,1(2,7-9,5)

    2,30 2,30 2,30 - 6,9(2,2-9,0)2,25 2,25 2,50 - 7,0(2,2-9,2)2,20 2,45 2,45 - 7,1(2,2-9,4)2,36 2,36 2,36 - 7,1(2,2-9,5)2,10 2,10 2,90 - 7,1(2,2-9,5)1,90 2,60 2,60 - 7,1(2,2-9,6)2,36 2,36 2,36 - 7,1(2,2-9,6)2,20 2,20 2,70 - 7,1(2,2-9,6)

    2,10 2,30 2,70 - 7,1(2,2-9,6)2,30 2,30 2,50 - 7,1(2,2-9,6)

    1,90 1,90 1,90 1,90 7,6(2,2-9,6)1,95 1,95 1,95 2,15 8,0(2,2-9,6)1,90 1,90 2,10 2,10 8,0(2,2-9,6)1,75 1,75 1,75 2,75 8,0(2,2-9,6)1,85 2,05 2,05 2,05 8,0(2,2-9,6)1,70 1,70 1,85 2,75 8,0(2,2-9,6)2,00 2,00 2,00 2,00 8,0(2,2-9,6)1,55 1,85 1,85 2,75 8,0(2,2-9,6)1,70 1,70 2,30 2,30 8,0(2,2-9,6)1,75 1,75 1,75 2,75 8,0(2,2-9,6)1,40 2,00 2,30 2,30 8,0(2,2-9,6)1,50 1,50 2,50 2,50 8,0(2,2-10,0)1,40 2,20 2,20 2,20 8,0(2,2-10,0)1,70 2,10 2,10 2,10 8,0(2,2-10,0)

     A B C D Total

    3,20 3,20 - - 6,2(2,5-8,2)3,20 4,00 - - 7,2(2,5-8,5)3,90 3,90 - - 7,8(3,0-9,3)2,90 5,00 - - 7,9(3,0-9,3)3,60 4,50 - - 8,1(3,1-9,9)3,90 3,90 - - 7,8(3,0-9,3)

    2,70 2,70 2,70 - 8,1(3,1-9,9)2,60 2,60 2,80 - 8,1(3,1-9,9)2,40 2,85 2,85 - 8,1(3,1-9,9)2,70 2,70 2,70 - 8,1(3,1-9,9)2,50 2,50 3,10 - 8,1(3,1-9,9)2,20 3,05 3,05 - 8,3(3,1-9,9)2,85 2,85 2,85 - 8,5(3,1-9,9)2,35 2,35 3,40 - 8,1(3,1-9,9)

    2,20 2,70 3,20 - 8,1(3,1-9,9)1,62 3,24 3,24 - 8,1(3,1-9,9)

    2,30 2,30 2,30 2,30 9,2(3,3-11,0)2,25 2,25 2,25 2,55 9,3(3,3+11,0)2,10 2,10 2,55 2,55 9,3(3,3-11,0)2,10 2,10 2,10 3,00 9,3(3,3-11,0)2,10 2,40 2,40 2,40 9,3(3,3-11,0)2,20 2,20 2,20 2,80 9,4(3,3-11,0)2,35 2,35 2,35 2,35 9,4(3,3-11,0)2,10 2,30 2,30 2,90 9,6(3,3-11,0)2,10 2,30 2,30 2,90 9,6(3,3-11,0)2,20 2,20 2,20 3,00 9,6(3,3-11,0)2,00 2,20 2,70 2,70 9,6(3,3-11,0)2,10 2,10 2,70 2,70 9,6(3,3-11,0)2,10 2,50 2,50 2,50 9,6(3,3-11,0)1,80 2,60 2,60 2,60 9,6(3,3-11,0)

     A B C D Total

    ACP-28COFM80GEEIUnit

         3     i    n     d    o    o    r    u    n     i    t

         4     i    n     d    o    o    r    u    n     i    t

    MULTI SPLIT SYSTEM - SUPER FREE MATCH

    COFM-GEEI series

  • 8/9/2019 VIVAX cool 2014.pdf

    32/36

    We reserve the right of eventual printing errors.30

    Heating operating temperature range -15°C

    Compressor With Electric Heater

    Memory function (auto restart)Automatic Defrosting

    Workable with SZC-16

    Workable

    with SZC-16

     

    outdoor unit - DC inverter

    Model ACP-48COFM140GEEI ACP-56COFM164GEEI

    Capacity Cooling 14000 (1000-16000) W 16000 (1000-18000) WHeating 16000 (1200-17400) W 18000 (1200-19000) W

    Refrigerant R410A R410AEnergy Efficiency EER 2.90 2.80

    COP 3.22 3.5Maximum number of indoor units 8 9Input power Cooling 4400 W 5000 W

    Heating 4250 W 4700 WOutdoor unit ≤58 dB(A) ≤58 dB(A)

    Sound power level Indoor unitOutdoor unit ≤68 dB(A) ≤68 dB(A)Outer Diameter of Liquid Pipe 3/8" 3/8"Outer Diameter of Gas Pipe 5/8" 3/4"Connection wire 5*2.5 mm² 5*2.5 mm²Power supply ~380~415V; 50Hz;3ph; outdoor unitMax. length of pipe 135 m 145 mMax elevation 30 m 30 mStandard length 30 m 30 mAdditional refrigerant 22 g/m (1/4”) + 50 g/m (3/8”) 22 g/m (1/4”) + 50 g/m (3/8”)Wall bracket distance(outdoor) 572 mm 572 mm

    Working range -15°C≤T≤48°C -15°C≤T≤48°CNet dimensions Outdoor unit 900×1345×340 mm 900×1345×340 mmNet weight Outdoor unit 116 kg 116 kg

    ACP-48COFM140GEEIACP-56COFM164GEEI

    Distributor box

  • 8/9/2019 VIVAX cool 2014.pdf

    33/36

    We reserve the right of eventual printing errors.31

    If two or three BU modules used, Y-type branch pipe of FQ01A/A will be chosen.

    FQ01A/A (Gas pipe)FQ01A/A (Liquid pipe)

    Smart Zone Controller SZC-16

    Branch pipe

     This smart zone controller is intended for multi VRF units and CF/CC/DT/CCIFM/DTIFM-

    GEEI type units, capable of controlling up to 3 sets of multi VRF units and multi sets of

    duct/cassette type units with maximum 16 indoor units.

     Through this smart zone controller, it is available to view and control those running

    parameters of the indoor unit, including on/off, running mode, fan speed etc, and also

    perform the single control and centralized control, further, it also can set the weekly

    timer and long-distance shielding to realize convenient control to the air conditioning

    system.

    a. Single control: it is intended to control the runningparameters of a designated indoor unit individually.

    b. Centralized control: it is intended to control the running

    parameters of all indoor units at the same time.

    c. Shielding under single or centralized control: it is intended

    to shield the running parameter of the indoor unit.

    d. Weekly timer under single or centralized control: it is

    intended to set when to start/stop the unit through long-

    distance control.

    e. Clock: it is intended to set and display the weekday, hour

    and minute.

     The outdoor unit of ACP-48COFM140GEEI and ACP-56COFM164GEEI must only adopt

    the BU modules in the following table.

    Model DB-3IDUB-K DB-5IDUB-K

    Maximum numbers of connectable indoor units 3 5

    Power Supply V-Ph-Hz 220~240-1-50

    Connection port tooutdoor unit

    Gas pipe(inner diameter) inch 5/8" 5/8"Liquid pipe(inner diameter) inch 3/8" 3/8"

    Connection Method Flare Flare

    Connection port toindoor unit

    Gas pipe(inner diameter) 3/8" 3/8"

    Liquid pipe(inner diameter) 1/4" 1/4"

    Connection Method Flare Flare

    Drainage pipeExternal dia. mm Φ31 Φ31 mm Φ31 Φ31

    Thickness mm 3 3

    Dimension(WxDxH)

    Outline mm 617×410×193

    Package mm 676×473×275

    Net weight/Gross weight kg 8/10 9/11

    MULTI SPLIT SYSTEM - SUPER FREE MATCH COFM-GEEI series

  • 8/9/2019 VIVAX cool 2014.pdf

    34/36

    We reserve the right of eventual printing errors.32

    Outdoor unit

    L1

    H1

    1A

    A B C

    BU1 BU2

    BU31B 1C 2A 2B 2C

    H2

    L2 L3

    L5

    H3

    H4

    3A

    3B

    L4 The 1st branch

     The 2nd

    branch

    Indoor unit A

    A

    B

    B

    C

    The sorts The pipes Length (m)

    Maximumallowable length

    Between outdoor unit and BU L1+L2+L3+L4+L5 ≤55

    Total length betweenindoor unit and BU

    ACP-48COFM140GEEI1A+1B+1C+2A+2B+2C+ 3A+3B

    ≤80

    ACP-56COFM164GEEI ≤90

    Between indoor unit and BU module 1A;1B;1C;2A;2B;2C;3A;3B ≤15

    Between indoor unit and the 1st branch L4+1B;L2+L5+2A;L2+L3+3B ≤40

    Maximumallowable length

    Between outdoor and indoor units H1 ≤30

    Between outdoor units and BU H2 ≤30

    Between BU and BU modules H3 ≤15

    Between indoor and indoor units H4 ≤15

    Minimum allowable lengthBetween outdoor and the 1st branch L1 ≥5

    Between BU and the branch L3;L4;L5 as possible as short

     Allowable Length/Height Differenceof Refrigerant Piping 

    MULTI SPLIT SYSTEM - SUPER FREE MATCH - combination

  • 8/9/2019 VIVAX cool 2014.pdf

    35/36

    We reserve the right of eventual printing errors.33

         T    w    o    u    n     i    t    s 2.1+3.5 2.6+6.2 3.5+7.0 6.2+6.2

    2.1+6.2 2.6+7.0 5.3+3.5 6.2+7.0

    2.1+7.0 3.5+5.3 3.5+6.2 7.0+7.0

    2.6+3.5 3.5+6.2 5.3+7.0

         T     h    r    e    e    u    n     i    t    s

    2.1+2.1+5.3 2.1+5.3+5.3 2.6+3.5+3.5 3.5+3.5+3.5 5.3+5.3+5.3

    2.1+2.1+6.2 2.1+5.3+6.2 2.6+3.5+5.3 3.5+3.5+5.3 5.3+5.3+6.2

    2.1+2.1+7.0 2.1+5.3+7.0 2.6+3.5+6.2 3.5+3.5+6.2 5.3+5.3+7.0

    2.1+2.6+3.5 2.1+6.2+6.2 2.6+3.5+7.0 3.5+3.5+7.0 5.3+6.2+6.2

    2.1+2.6+5.3 2.1+6.2+7.0 2.6+5.3+5.3 3.5+5.3+5.3 5.3+6.2+7.0

    2.1+2.6+6.2 2.1+7.0+7.0 2.6+5.3+6.2 3.5+5.3+6.2 5.3+7.0+7.0

    2.1+2.6+7.0 2.6+2.6+3.5 2.6+5.3+7.0 3.5+5.3+7.0 6.2+6.2+6.2

    2.1+3.5+3.5 2.6+2.6+5.3 2.6+6.2+6.2 3.5+6.2+6.2 6.2+6.2+7.0

    2.1+3.5+3.5 2.6+2.6+6.2 2.6+6.2+7.0 3.5+6.2+7.0 6.2+7.0+7.0

    2.1+3.5+6.2 2.6+2.6+7.0 2.6+7.0+7.0 3.5+7.0+7.0 7.0+7.0+7.0

         F    o    u    r    u    n     i    t    s

    2.1+2.1+2.1+2.1 2.1+2.1+6.2+7.0 2.1+3.5+3.5+7.0 2.6+2.6+3.5+ 6.2 2.6+5.3+5.3+7.0

    2.1+2.1+2.1+2.6 2.1+2.1+7.0+7.0 2.1+3.5+3.5+5.3 2.6+2.6+3.5+7.0 2.6+5.3+6.2+6.2

    2.1+ 2.1+2.1+3.5 2.1+2.6+2.6+2.6 2.1+3.5+5.3+6.2 2.6+2.6+5.3+5.3 2.6+5.3+6.2+7.0

    2.1+2.1+2.1+5.3 2.1+2.6+2.6+3.5 2.1+3.5+5.3+7.0 2.6+2.6+5.3+6.2 2.6+6.2+6.2+6.2

    2.1+2.1+2.1+6.2 2.1+2.6+2.6+5.3 2.1+3.5+6.2+6.2 2.6+2.6+5.3+7.0 3.5+3.5+3.5+3.5

    2.1+2.1+2.1+7.0 2.1+2.6+2.6+6.2 2.1+3.5+6.2+7.0 2.6+2.6+6.2+6.2 3.5+3.5+3.5+5.3

    2.1+2.1+2.6+2.6 2.1+2.6+2.6+7.0 2.1+5.3+5.3+5.3 2.6+2.6+6.2+7.0 3.5+3.5+3.5+6.2

    2.1+2.1+2.6+ 2.6 2.1+2.6+3.5+3.5 2.1+3.5+3.5+6.2 2.6+2.6+7.0+7.0 3.5+3.5+3.5+7.0

    2.1+2.1+2.6+3.5 2.1+2.6+3.5+5.3 2.1+3.5+3.5+7.0 2.6+3.5+3.5+3.5 3.5+3.5+5.3+5.3

    2.1+2.1+2.6+5.3 2.1+2.6+3.5+6.2 2.1+5.3+6.2+6.2 2.6+3.5+3.5+3.5 3.5+3.5+ 5.3+6.2

    2.1+2.1+2.6+6.2 2.1+2.6+3.5+7.0 2.1+5.3+6.2+7.0 2.6+3.5+3.5+6.2 3.5+3.5+3.5+7.0

    2.1+2.1+2.6+7.0 2.1+2.6+5.3+5.3 2.1+5.3+7.0+7.0 2.6+3.5+3.5+7.0 3.5+3.5+6.2+ 6.22.1+2.1+3.5+3.5 2.1+2.6+5.3+6.2 2.1+6.2+6.2+6.2 2.6+3.5+5.3+5.3 3.5+3.5+6.2+7.0

    2.1+2.1+3.5+3.5 2.1+ 2.6+5.3+7.0 2.6+2.6+2.6+2.6 2.6+3.5+5.3+6.2 3.5+3.5+7.0+7.0

    2.1+2.1+3.5+6.2 2.1+2.6+6.2+6.2 2.6+ 2.6+2.6+3.5 2.6+3.5+5.3+7.0 3.5+5.3+5.3+5.3

    2.1+2.1+3.5+7.0 2.1+2.6+6.2+7.0 2.6+2.6+2.6+5.3 2.6+3.5+6.2+6.2 3.5+5.3+5.3+6.2

    2.1+2.1+5.3+5.3 2.1+2.6+ 7.0+7.0 2.6+2.6+2.6+6.2 2.6+3.5+6.2+7.0 3.5+5.3+5.3+7.0

    2.1+2.1+5.3+6.2 2.1+3.5+3.5+3.5 2.6+2.6+ 2.6+7.0 2.6+3.5+7.0+7.0 3.5+5.3+6.2+6.2

    2.1+2.1+5.3+7.0 2.1+3.5+3.5+ 3.5 2.6+2.6+3.5+3.5 2.6+5.3+5.3+5.3 5.3+5.3+5.3+5.3

    2 .1+ 2. 1+ 6.2 +6 .2 2. 1+ 3. 5+ 3. 5+ 6. 2 2. 6+ 2. 6+ 3. 5+ 3. 5 2. 6+ 3. 5+ 3. 5+ 6. 2

         F     i    v    e    u    n     i    t    s

    2.1-2.1+2.1+2.1+2.1 2.1+2.1+2.6+2.6+3.5 2.1+2.1+5.3+5.3+5.3 2.1+2.6+3.5+5.3+7.0 2.6+2.6+2.6+6.2+7.0

    2.1+2.1+2.1+2.1+2.6 2.1+2.1+2.6+2.6+3.5 2.1+2.1+5.3+5.3+6.2 2.1+2.6+3.5+6.2+6.2 2.6+2.6+3.5+3.5+3.5

    2.1+2.1+2.1+2.1+3.5 2.1+2.1+2.6+2.6+6.2 2.1+2.6+2.6+2.6+2.6 2.1+2.6+5.3+5.3+5.3 2.6+2.6+3.5+3.5+5.3

    2.1+2.1+2.1+2.1+5.3 2.1+2.1+2.6+2.6+7.0 2.1+2.6+2.6+2.6+3.5 2.1+3.5+3.5+3.5+3.5 2.6+2.6+3.5+3.5+6.2

    2.1+2.1+2.1+2.1+6.2 2.1+2.1+2.6+3.5+3.5 2.1+2.6+2.6+2.6+5.3 2.1+3.5+3.5+3.5+5.3 2.6+2.6+3.5+3.5+7.02.1+2.1+2.1+2.1+2-1 2.1+2.1+2.6+3.5+5.3 2.1+2.6+2.6+2.6+6.2 2.1+3.5+3.5+3.5+6.2 2.6+2.6+3.5+5.3+5.3

    2.1+2.1+2.1+2.6+2.6 2.1+2.1+2.6+3.5+6.2 2.1+2.6+2.6+2.6+7.0 2.1+3.5+3.5+3.5+7.0 2.6+2.6+3.5+5.3+6.2

    2.1+2.1+2.1+2.6+3.5 2.1+2.1+2.6+3.5+7.0 2.1+2.6+2.6+3.5+3.5 2.1+3.5+3.5+5.3+5.3 2.6+2.6+3.5+5.3+7.0

    2.1+2.1+2.1+2.6+5.3 2.1+2.1+2.6+5.3+5.3 2.1+2.6+2.6+3.5+5.3 2.1+3.5+3.5+5.3+6.2 2.6+2.6+3.5+6.2+6.2

    2.1+2.1+2.1+2.6+6.2 2.1+2.1+2.6+5.3+6.2 2.1+2.6+2.6+3.5+6.2 2.6+2.6+2.6+2.6+2.6 2.6+2.6+5.3+5.3+5.3

    2.1+2.1+2.1+2.6+7.0 2.1+2.1+2.6+5.3+7.0 2.1+2.6+2.6+3.5+7.0 2.6+2.6+2.6+2.6+3.5 2.6+3.5+3.5+3.5+3.5

    2.1+2.1+2.1+3.5+3.5 2.1+2.1+2.6+6.2+7.0 2.1+2.6+2.6+5.3+5.3 2.6+2.6+2.6+2.6+5.3 2.6+3.5+3.5+3.5+5.3

    2.1+2.1+2.1+3.5+5.3 2.1+2.1+2.6+7.0+7.0 2.1+2.6+2.6+5.3+6.2 2.6+2.6+2.6+2.6+6.2 2.6+3.5+3.5+3.5+6.2

    2.1+2.1+2.1+3.5+6.2 2.1+2.1+3.5+3.5+3.5 2.1+2.6+2.6+5.3+7.0 2.6+2.6+2.6+2.6+7.0 2.6+3.5+3.5+3.5+7.0

    2.1+2.1+2.1+3.5+7.0 2.1+2.1+3.5+3.5+5.3 2.1+2.6+2.6+6.2+6.2 2.6+2.6+2.6+3.5+3.5 2.6+3.5+3.5+5.3+5.3

    2.1+2.1+2.1+5.3+5.3 2.1+2.1+3.5+3.5+6.2 2.1+2.6+2.6+6.2+7.0 2.6+2.6+2.6+3.5+5.3 2.6+3.5+3.5+5.3+6.2

    2.1+2.1+2.1+5.3+6.2 2.1+2.1+3.5+3.5+7.0 2.1+2.6+3.5+3.5+3.5 2.6+2.6+2.6+3.5+6.2 3.5+3.5+3.5+3.5+3.5

    2.1+2.1+2.1+5.3+7.0 2.1+2.1+3.5+5.3+5.3 2.1+2.6+3.5+3.5+5.3 2.6+2.6+2.6+3.5+7.0 3.5+3.5+3.5+3.5+5.32.1+2.1+2.1+6.2+6.2 2.1+2.1+3.5+3.5+6.2 2.1+2.6+3.5+3.5+6.2 2.6+2.6+2.6+5.3+5.3 3.5+3.5+3.5+3.5+6.2

    2.1+2.1+2.1+6.2+7.0 2.1+2.1+3.5+5.3+7.0 2.1+2.6+3.5+3.5+7.0 2.6+2.6+2.6+5.3+6.2 3.5+3.5+3.5+3.5+7.0

    2.1+2.1+2.1+7.0+7.0 2.1+2.1+3.5+6.2+6.2 2.1+2.6+3.5+5.3+5.3 2.6+2.6+2.6+5.3+7.0 3.5+3.5+3.5+5.3+5.3

    2.1+2.1+2.6+2.6+2.6 2.1+2.1+3.5+6.2+7.0 2.1+2.6+3.5+5.3+6.2 2.6+2.6+2.6+6.2+6.2

         S     i    x    u    n     i    t    s

    2.1+2.1+2.1+2.1+2.1+2.1 2.1+2.1+2.1+2.6+3.5+3.5 2.1+2.1+2.6+2.6+3.5+6.2 2.1+2.6+2.6+3.5+3.5+6.22.1+2.1+2.1+2.1+2.1+2.6 2.1+2.1+2.1+2.6+3.5+5.3 2.1+2.1+2.6+2.6+3.5+7.0 2.1+2.6+3.5+3.5+3.5+3.5

    2.1+2.1+2.1+2.1+2.1+3.5 2.1+2.1+2.1+2.6+3.5+6.2 2.1+2.1+2.6+2.6+5.3+5.3 2.1+2.6+3.5+3.5+3.5+5.3

    2.1+2.1+2.1+2.1+2.1+5.3 2.1+2.1+2.1+2.6+3.5+7.0 2.1+2.1+2.6+2.6+5.3+6.2 2.1+3.5+3.5+3.5+3.5+3.5

    2.1+2.1+2.1*2.1+2.1+6.2 2.1+2.1+2.1+2.6+5.3+5.3 2.1+2.1+2.6+3.5+3.5+3.5 2.6+2.6+2.6+2.6+2.6+2.6

    2.1+2.1+2.1+2.1+2.1+7.0 2.1+2.1+2.1+2.6+5.3+6.2 2.1+2.1+2.6+3.5+3.5+5.3 2.6+2.6+2.6+2.6+2.6+3.5

    2.1+2.1+2.1+2.1+2.6+2.6 2.1+2.1+2.1+2.6+5.3+7.0 2.1+2.1+2.6+3.5+3.5+6.2 2.6+2.6+2.6+2.6+2.6+5.3

    2.1+2.1+2.1+2.1+2.6+3.5 2.1+2.1+2.1+2.6+6.2+6.2 2.1+2.1+2.6+3.5+3.5+7.0 2.6+2.6+2.6+2.6+2.6+6.2

    2.1+2.1+2.1+2.1+2.6+5.3 2.1+2.1+2.1+3.5+3.5+3.5 2.1+2.1+2.6+3.5+5.3+5.3 2.6+2.6+2.6+2.6+2.6+7.0

    2.1+2.1+2.1+2.1+2.6+6.2 2.1+2.1+2.1+3.5+3.5+5.3 2.1+2.6+2.6+2.6+2.6+2.6 2.6+2.6+2.6+2.6+3.5+3.5

    2.1+2.1+2.1+2.1+2.6+7.0 2.1+2.1+2.1+3.5+3.5+6.2 2.1+2.6+2.6+2.6+2.6+3.5 2.6+2.6+2.6+2.6+3.5+5.3

    2.1+2.1+2.1+2.1+3.5+3.5 2.1+2.1+2.1+3.5+3.5+7.0 2.1+2.6+2.6+2.6+2.6+5.3 2.6+2.6+2.6+2.6+3.5+6.2

    2.1+2.1+2.1+2.1+3.5+5.3 2.1+2.1+2.1+3.5+5.3+5.3 2.1+2.6+2.6+2.6+2.6+6.2 2.6+2.6+2.6+2.6+3.5+7.0

    2.1+2.1+2.1+2.1+3.5+6.2 2.1+2.1+2.1+3.5+5.3+6.2 2.1+2.6+2.6+2.6+2.6+7.0 2.6+2.6+2.6+2.6+5.3+5.32.1+2.1+2.1+2.1+3.5+7.0 2.1+2.1+2.6+2.6+2.6+2.6 2.1+2.6+2.6+2.6+3.5+3.5 2.6+2.6+2.6+3.5+3.5+3.5

    2.1+2.1+2.1+2.1+5.3+5.3 2.1+2.1+2.6+2.6+2.6+3.5 2.1+2.6+2.6+2.6+3.5+5.3 2.6+2.6+2.6+3.5+3.5+5.3

    2.1+2.1+2.1+2.6+2.6+2.6 2.1+2.1+2.6+2.6+2.6+5.3 2.1+2.6+2.6+2.6+3.5+6.2 2.6+2.6+2.6+3.5+3.5+6.2

    2.1+2.1+2.1+2.6+2.6+3.5 2.1+2.1+2.6+2.6+2.6+6.2 2.1+2.6+2.6+2.6+3.5+7.0 2.6+2.6+3.5+3.5+3.5+3.5

    2.1+2.1+2.1+2.6+2.6+5.3 2.1+2.1+2.6+2.6+2.6+7.0 2.1+2.6+2.6+2.6+5.3+5.3 2.6+2.6+3.5+3.5+3.5+5.3

    2.1+2.1+2.1+2.6+2.6+6.2 2.1+2.1+2.6+2.6+3.5+3.5 2.1+2.6+2.6+3.5+3.5+3.5 2.6+3.5+3.5+3.5+3.5+3.5

    2.1+2.1+2.1+2.6+2.6+7.0 2.1+2.1+2.6+2.6+3.5+5.3 2.1+2.6+2.6+3.5+3.5+5.3 3.5+3.5+3.5+3.5+3.5+3.5

    2.1+2.1+2.1+2.6+3.5+3.5

         S    e    v    e    n    u    n     i    t    s

    2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .1 2 .1 +2 .1 +2 .1 +2 .1 +2 .6 +2 .6 +6 .2 2 .1 +2 .1 +2 .6 +2 .6 +2 .6 +2 .6 +3 .5

    2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .6 2 .1 +2 .1 +2 .1 +2 .1 +2 .6 +2 .6 +7 .0 2 .1 +2 .1 +2 .6 +2 .6 +2 .6 +2 .6 +5 .3

    2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +3 .5 2 .1 +2 .1 +2 .1 +2 .1 +2 .6 +3 .5 +3 .5 2 .1 +2 .1 +2 .6 +2 .6 +2 .6 +2 .6 +6 .2

    2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +5 .3 2 .1 +2 .1 +2 .1 +2 .1 +2 .6 +3 .5 +5 .3 2 .1 +2 .1 +2 .6 +2 .6 +2 .6 +3 .5 +3 .52 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +6 .2 2 .1 +2 .1 +2 .1 +2 .1 +2 .6 +3 .5 +6 .2 2 .1 +2 .1 +2 .6 +2 .6 +2 .6 +3 .5 +5 .3

    2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +7 .0 2 .1 +2 .1 +2 .1 +2 .1 +3 .5 +3 .5 +3 .5 2 .1 +2 .1 +2 .6 +2 .6 +3 .5 +3 .5 +3 .5

    2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .6 +2 .6 2 .1 +2 .1 +2 .1 +2 .1 +3 .5 +3 .5 +5 .3 2 .1 +2 .1 +2 .6 +3 .5 +3 .5 +3 .5 +3 .5

    2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .6 +3 .5 2 .1 +2 .1 +2 .1 +2 .6 +2 .6 +2 .6 +2 .6 2 .1 +2 .6 +2 .6 +2 .6 +2 .6 +2 .6 +2 .6

    2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .6 +5 .3 2 .1 +2 .1 +2 .1 +2 .6 +2 .6 +2 .6 +3 .5 2 .1 +2 .6 +2 .6 +2 .6 +2 .6 +2 .6 +3 .5

    2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .6 +6 .2 2 .1 +2 .1 +2 .1 +2 .6 +2 .6 +2 .6 +5 .3 2 .1 +2 .6 +2 .6 +2 .6 +2 .6 +2 .6 +5 .3

    2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .6 +7 .0 2 .1 +2 .1 +2 .1 +2 .6 +2 .6 +2 .6 +6 .2 2 .1 +2 .6 +2 .6 +2 .6 +2 .6 +3 .5 +3 .5

    2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +3 .5 +3 .5 2 .1 +2 .1 +2 .1 +2 .6 +2 .6 +2 .6 +7 .0 2 .1 +2 .6 +2 .6 +2 .6 +3 .5 +3 .5 +3 .5

    2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +3 .5 +5 .3 2 .1 +2 .1 +2 .1 +2 .6 +2 .6 +3 .5 +3 .5 2 .6 +2 .6 +2 .6 +2 .6 +2 .6 +2 .6 +2 .6

    2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +3 .5 +6 .2 2 .1 +2 .1 +2 .1 +2 .6 +2 .6 +3 .5 +5 .3 2 .6 +2 .6 +2 .6 +2 .6 +2 .6 +2 .6 +3 .5

    2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +3 .5 +7 .0 2 .1 +2 .1 +2 .1 +2 .6 +2 .6 +3 .5 +6 .2 2 .6 +2 .6 +2 .6 +2 .6 +2 .6 +2 .6 +5 .3

    2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +5 .3 +5 .3 2 .1 +2 .1 +2 .1 +2 .6 +3 .5 +3 .5 +3 .5 2 .6 +2 .6 +2 .6 +2 .6 +2 .6 +3 .5 +3 .5

         E     i    g     h    t    u    n     i    t    s

    2.1+2.1+2.1+2.1+2.1+2.1+2.1+2.1 2.1+2.1+2.1+2.1+2.1+2.1+2.6+6.2 2.1+2.1+2.1+2.6+2.6+2.6+2.6+2.62.1+2.1+2.1+2.1+2.1+2.1+2.1+2.6 2.1+2.1+2.1+2.1+2.1+2.1+3.5+3.5 2.1+2.1+2.1+2.6+2.6+2.6+2.6+3.5

    2.1+2.1+2.1+2.1+2.1+2.1+2.1+3.5 2.1+2.1+2.1+2.1+2.1+2.1+3.5+5.3 2.1+2.1+2.1+2.6+2.6+2.6+3.5+3.5

    2.1+2.1+2.1+2.1+2.1+2.1+2.1+5.3 2.1+2.1+2.1+2.1+2.1+2.6+2.6+2.6 2.1+2.1+2.6+2.6+2.6+2.6+2.6+2.6

    2.1+2.1+2.1+2.1+2.1+2.1+2.1+6.2 2.1+2.1+2.1+2.1+2.1+2.6+2.6+3.5 2.1+2.1+2.6+2.6+2.6+2.6+2.6+3.5

    2.1+2.1+2.1+2.1+2.1+2.1+2.6+2.6 2.1+2.1+2.1+2.1+2.1+2.6+2.6+5.3 2.6+2.6+2.6+2.6+2.6+2.6+2.6+2.6

    2.1+2.1+2.1+2.1+2.1+2.1+2.6+3.5 2.1+2.1+2.1+2.1+2.1+2.6+3.5+3.5

    2.1+2.1+2.1+2.1+2.1+2.1+2.6+5.3 2.1+2.1+2.1+2.1+2.1+3.5+3.5+3.5

         N     i    n    e    u    n     i    t    s

    2.1+2.1+2.1+2.1+2.1+2.1+2.1+2.1+2.1 2.1+2.1+2.1+2.1+2.1+2.1+2.1+2.6+3.5

    2.1+2.1+2.1+2.1+2.1+2.1+2.1+2.1+2.6 2.1+2.1+2.1+2.1+2.1+2.1+2.6+2.6+2.6

    2.1+2.1+2.1+2.1+2.1+2.1+2.1+2.1+3.5 2.1+2.1+2.1+2.1+2.1+2.1+2.6+2.6+3.5

    2.1+2.1+2.1+2.1+2.1+2.1+2.1+2.6+2.6 2.1+2.1+2.1+2.1+2.1+2.6+2.6+2.6+2.6

    ACP-56COFM164GEEIThe most common indoor units combinations.

     

  • 8/9/2019 VIVAX cool 2014.pdf

    36/36

    We reserve the right of eventual printing errors.34

    M SAN Grupa d.d.

    Exclusive distributor for Republic of CroatiaBuzinski prilaz 10, 10010 Buzin, Zagreb, CroatiaT +385 1 3654 900 | F +385 1 3654 [email protected]     V

        I    V    A    X    P

       a   r    t   n   e   r

    vivax.com