vivax cool 2014.pdf
TRANSCRIPT
-
8/9/2019 VIVAX cool 2014.pdf
1/36
We reserve the right of eventual printing errors.1
A i r c o n d i t i oners c a t a l o
g u e
2 0
1 4
A + +
1 W
s t a n d
b y
G 10 t ehno l o g y
L o w
n o i s
e
I F e e l
7 -
f a n
s
p e e d s
L o w
h e
a t i n g
- 2 0 ° C
L o w c
o o l i n
g - 1
5 ° C
-
8/9/2019 VIVAX cool 2014.pdf
2/36
We reserve the right of eventual printing errors.2
model: ACP-18CC50GEEI
-
8/9/2019 VIVAX cool 2014.pdf
3/36
We reserve the right of eventual printing errors.3
2. Functions
4. Vivax technology
6. Function description
7. Vivax multi split - DC inverter systems – introduction
8. Products Overview
10. WALL SPLIT SYSTEM - GEYI series
GEEI series
AELI series
14. MOBILE AIR CONDITIONERS - AEH series
15. FLOOR SPLIT SYSTEMS - CT-GEEI series
16. FLOOR CEILING SPLIT SYSTEM - CF-GEEI series
17. CASSETTE SPLIT SYSTEM - CC-GEEI series
18. DUCT SPLIT SYSTEM - DT-GEEI series19. OUTDOOR UNITS CC/CF/DT-GEEI series
20. DUAL SPLIT SYSTEM with two indoor units - AEEI series
22. MULTI SPLIT SYSTEM - CIFM-GEEI series (wall)
CTIFM-GEEI series (floor)
CCIFM-GEEI series (cassette)
DTIFM-GEEI series (duct)
COFM-GEEI series (outdoor units)
29. MULTI SPLIT SYSTEM - combination
30. MULTI SPLIT SYSTEM - SUPER FREE MATCH
31. MULTI SPLIT SYSTEM - SUPER FREE MATCH
Distributor box, Branch pipe, Smart Zone Controller SZC-16
32. MULTI SPLIT SYSTEM - SUPER FREE MATCH
Allowable Length/Height Difference of Refrigerant Piping33. SUPER FREE MATCH - combinations
Contents
-
8/9/2019 VIVAX cool 2014.pdf
4/36We reserve the right of eventual printing errors.2
Function
RELIABILITY
COMFORT
-15°C/-20°C HEATING
The device can be used for heating at low outdoortemperatures with high efficiency.
LOW AMBIENT KITAllows operation of the unit in cooling mode at low outdoor
temperature.
PTC HEATERAdditional heaters, one heater is used for heating oil in the
compressor, and second one improves defrosting of the
outdoor unit. Heater operation is controlled by the main
processor. This management control enables a smooth and
safe operation when the outdoor temperature reaches -15 °C.
LOW TEMPERATURE STARTUP
The device is functioning normally and begins to work andheat, even when outdoor temperature is lower than -15 ° C.
LOW VOLTAGE STARTUP
The unit could operate from 170V to 265V which is suitable
for unstable power supply areas.
INTELLIGENT DEFROSTING
I-defrosting is only performed when needed, which reduces
energy waste by eliminating the unnecessary defrostingprocess.
SELF DIAGNOSIS DISPLAYING
Display the error description on LED display for faster and
easier solutions of the resulting problems.
VALVE PROTECTION COVEROutdoor unit valves protection.
REFRIGERANT LEAKAGE DETECT
The indoor unit will display error code “EC” when the
system detects refrigerant leakage. This new technology
can better protect the compressor.
8°C HEATINGMaintain the room temperature steadily at 8° C and prevent
the room from freezing by heating operation when nobody
is at home for long in severe winter.
7-FAN SPEEDS
A large variety of different fan speeds of indoors unit enables
quieter operation device which makes the stay in the areaenjoyable.
3-FAN SPEEDS
Three fan speeds of the indoor unit.
I FEEL (follow me) The mini sensor in the remote controller can sense its
surrounding temperature, and transmit the signal back
to the indoor unit. So, the unit can adjust the air flow
volume and temperature accordingly so as to provide
maximum comfort.
TURBO
With this function, the air conditioner will maximize the
output of cooling or heating capacity, make the room
cool down or heat up rapidly, and attain the desired
temperature in the shortest time.
INTELLIGENT ANTI-COLD-AIR FUNCTION
Conventional anti-cold-air function works only
by evaporator temperature. Vivax intelligent anti-
cold-air function works by both evaporator and
ambient temperature, more accurate control ensure
comfortable feeling.
QUIET DESIGN
The special design of the air blower provides dampingand noise reduction during operation.
CLOCK DISPLAY
Digital clock display is enabled on LED display of device.
TEMPERATURE COMPENSATION
Temperature Compensation.
12 GRADE INDOOR FAN SPEED AELI SERIES
9,12,18K
Improve indoor fan speeds from 6 grades (SH/H/M/L/S/SS) to 12 grades (SH/H+/H/H-/M+/M/M-/L+/L/L-
/S/SS), ensure more accurate control and bring more
comfortable air flow.
5 GRADES OUTDOOR FAN SPEED AELI SERIES
9,12,18K
Upgrade outdoor fan speeds from 3 grades to 5 grades.
According to the temperature difference, the outdoor
unit can change the outdoor fan speed automatically
to realize high heat exchange efficiency and save
energy.
-
8/9/2019 VIVAX cool 2014.pdf
5/36We reserve the right of eventual printing errors.3
HEALTH
PRACTICALITY
ENERGY SAVING
SELF CLEANING
By pressing the button “CLEAN” on the remote control, the devicewill automatically start with cleaning the indoor unit. This function
will eliminate the bacteria and their reproduction, and the air
becomes cleaner and fresher.
DRY MOULD PROOF The fan remains to work after turning off the device in order to dry
up the moisture that remains in the indoor unit.
COLD CATALYST FILTER
AUTO OPERATION
The device offers the possibility of adjusting the automatic mode.
By selecting this function, the device automatically determines
the fan speed of the indoor unit and mode, comparing the set
temperature and current conditions in the area.
MEMORY FUNCTIONWhen the power is off and then on, the unit automatically restores
the previous function settings.
LED DISPLAY
LED display functions overview.
TIMER Timer allows initiation and termination of devices from within a
period of 24 hours.
WIDE ANGLE LOUVERS SYSTEM
Distributes a stream of air to a wider area , to every corner of theworkspace.
COMFORTABLE SLEEP FUNCTION
Temperature is slightly rising or fallingautomatically in order to preserve the pleasant
room temperature, and also reduce energyconsumption.
1W STANDBY
0,5W STANDBY
-
8/9/2019 VIVAX cool 2014.pdf
6/36We reserve the right of eventual printing errors.4
Commission Delegated Regulation (EU) No 626/2011
Technological developments in the energy efficiency improvement of air conditioners have been very rapid in recent years. This has allowed European
Authority to introduce stringent minimum energy efficiency requirements and led to a process of introducing new energy labelling schemes based onseasonal performance. Today’s appliances, excluding single and double duct air conditioners, that achieve the highest efficienc y levels have largely surpassedthe A efficiency levels established by Directive 2002/31/EC.
This Regulation introduces two energy efficiency scales based on the primary function and on specific aspects important to consumer. Given that airconditioners are used mainly in part-load conditions, the efficiency testing should be changed to a seasonal efficiency measurement method, except forsingle and double duct air conditioners. The seasonal measurement method takes better into account the benefits of the inverter driven technology and theconditions in which these appliances are used. The new efficiency calculation method with an Ecodesign implementing measure setting minimum energyefficiency requirements higher than the current A level, will lead to a reclassification of these appliances. Consequently, split, window and wall air conditionersshould have a new A-G energy efficiency class scale with a “+” added on the top of the scale every two years until the A+++ class has been reached.
Vivax technologyHIGH EFFICIENCYVivax models from residential tocommercial are reaching New classA ranking, the highest level thatis now shown on energy label in
European union.
New Energy Labelling Requirement(EU) 626/2011
• Three climate zones for heating(Average zone is mandatory, warmerand colder zone are voluntary)• Seasonal eciency (performancebased on multiple part loadscalculation)Sound power level• Rated eciency indicates
performance only data ratedcondition.Seasonal efficiency indicatesperformance at an entire coolingand heating season, which bettermatches the actual operation.
0.5W StandbyIntelligent on-off technology enables Vivaxproducts automatically enter energy-savingmode when on standby mode, cut energyconsumption from conventional 5W to 0.5Wwhich counts 90% of saving.
Intelligent Anti-cold-air FunctionConventional anti-cold-air function worksonly by evaporator temperature. Vivaxintelligent anti-cold-air function works by
both evaporator and ambient temperature,more accurate control ensure comfortablefeeling.
Wide Operation RangeUp to 25 stages (F1-F25) of compressor frequency, andfrequency range increased around 70%. More comfortableand energy saving due to smooth and accurate control.With advanced frequency-adjusting technology,compressor preheating function and the electrical heatingbelts, the unit can operate heating as low as -20°C.
Power Factor Correction(PFC) Technology
With advanced partialactive PFC control, theinput current waveform andvoltage waveform get phasesynchronization, more than97% of the input powersupply is used effectively,which greatly improve powertransformation efficiency.
Brushless DC Fan Motor
The brushless DC fan motorallows fine rotation control,which reduces energyconsumption. The efficiencyof brushless DC motor is upto 35% higher than that of
the equivalent AC motor.
-
8/9/2019 VIVAX cool 2014.pdf
7/36We reserve the right of eventual printing errors.5
quickly
reaches
the desired
temperature
for
Inverter
ne-inverter
fix-speedhot
hot
comfortable
cold
cold
Ultra low frequency torque control
High-speed DSP chip
Environment-friendly R410A
refrigerant
Ultra-low noise control
Automatic voltage adaptation
High reliability
Wide frequency precise control
UHF flux-weakening control
Computer simulation control
Power factor correction technology
Innovative DC inverter technology precisely and in
every given moment and in all working conditions
ensures cooling and heating capacity according to
given space conditions. With the purpose to improve
efficiency in heating mode, Vivax DC inverter air conditioner has developed technology that
enables undisturbed work even up to -20 °C – G10 Inverter technology.
Owing to a special type of oils that are not losing attributes (primarily viscosity) at low
temperatures functionality of air conditioning goes seamlessly even at low temperatures.
Besides G10 Inverter technology Vivax DC inverter air conditioners have retained the possibility
to work in heating mode under low temperatures (up to -15 °C) due to additional heaters, it
depends on the air conditioner series whether the heaters are installed into compressor or
into condenser. One heater heats oil in the compressor while other improves defrosting of
outdoor unit. Operation of those heaters is controlled by a main processor which receivesdata from outdoor unit sensor important for normal operation. Standard air conditioners
have compressors that usually operate under constant speed. Inverter technology is the only
technology that follows speed operation electronically. Compressor is operating under the
highest speed if there is a big difference between default temperature and room temperature.
When default temperature is reached compressor slows down. Inverter operation system
saves up to 50% of energy. If the room temperature is high, air conditioner will operate under
full power until default temperature is reached. Once default temperature is reached the
operational power is decreased sufficiently enough to evenly maintain default temperature.
Thereby, sudden changes in room temperature are being avoided and significant energy
savings is accomplished. There is no frequent turning on and turning off of device that is
additionally overloading electricity grid, therefore, “draft” syndrome is being avoided.
ADVANTAGES-precise regulation of default temperature
-fast reaching of default temperature-reduced temperature variation
-higher comfort of conditioned space
-possibility of heating even on -20°C
-saving energy-no power strokes
-
8/9/2019 VIVAX cool 2014.pdf
8/36We reserve the right of eventual printing errors.6
Funtions for Low Ambient Temperature
8°C Heating
Maintain the room temperature steadily at 8°C and prevent theroom from freezing by heating operation when nobody is athome for long in severe winter.
3 Sleep Curves
• Mod 1: indoor temperature automatically rises (when
cooling) or drops (when heating)• Mod 2: featuring unique refreshment function, the
temperature is automatically adjusted to be a little lower
before you wake up.
• Mod 3: You could design your own sleep curve under DIY
mode.
Function description
Time
Temperature
Sleep Curve for Cooling
Intelligent Defrosting
Vivax intelligent defrosting Generally defrost
Maximize warm comfort with shorter defrosting time. Traditional defrosting works by setting time. E.g. defrosting process is onfor 10mins for every 50 mins. VIVAX I-Defrosting is only performen whenneeded, which redusces energy waste by eliminating the unnecessarydefrosting process.
-15°C Cooling
Cooling at -15°C while keep a reliable operation. As the outdoortemperature changes, the frequency of compressor and thespeed of fan adjustus accordingly.
-20°C Heating
Operate finely when heating at -20°C. It is supported by VIVAX’selectrical heating chassis, preheating technology and frequency-adjusting compressor.
-
8/9/2019 VIVAX cool 2014.pdf
9/36We reserve the right of eventual printing errors.7
Bio filtar IonizatorCatechin filtar Active carbon filter
In this year Vivax presents you the forth generation of multi split DC
inverter air conditioners which are ideal solution for conditioning of
your business or residential spaces.
All devices are designed to please users and space requests regarding
cooling and heating. New technological solutions enable high power
efficiency of one device under all climate conditions whether used for
cooling or for heating.
Vide capacity range of outdoor units (from 5.00 – 16.50 kW) and
possibility to connect maximum 9 indoor units allows far-reaching
of this devices by emphasising commercial and residential premises.
The maximum length of installation is 145m* which allows easy
positioning of device regarding relation outdoor unit and external
object dimensions, therefore it is now very simple to position outdoor
unit on the roof or on the backyard side without disturbing external
appearance. Indoor units come in three different types: wall mounted,
cassette, floor and it is possible to choose between 8 different indoor
units with capacity range: 2.10 - 7.10 kW. Attractive design and low
noise level will provide comfortable atmosphere.
Apartments, flats, family houses, office space, shops, restaurants and
special purpose facilities are just a part of spaces that Vivax multi split
DC Inverter devices can heat or cool.
Durability of this device, acceptable price and A class of energy
efficiency are the guarantee of the best choice which pust Vivax multi
split DC Inverter among the leading air conditioners in this segment.
Bacteria Dust NH3
HCHO Fungi Microbes Smoke Pollen Anions
ACTIVE CARBON FILTARActive carbon filter is produced out of activated carbonl
and electrostatic fibre material. It absorbs different kinds
of materials either in gas or in liquid form. This filter has big
capacity, capability of fast absorption of harmful gasses
(such as ammonium and hydrogen sulphide) and other
odours. Electrostatic fibre filter collects small particles of
dust, smoke and animal hairs to prevent allergic reactions
by forming a specific position on the surface of the filter.
BIO FILTERBio filter consists of special biological enzymes and eco
filters. Eco filter collects small particles of dust, bacteria,
fungus and microbes. Biological enzymes remove bacteria
by dissolving their cell walls and remove the possibility to
re-pollute the air in the room.
IONIZERAnions are taking care of your body by stimulating
circulation, improvement of your lungs capacity and
preventing airway diseases (e.g. asthma). Negative ions
are eliminating dust and smoke, when air circulates
through the ionizer, anions automatically start to act. The
amount of anions can reach maximum of 1.000.000 cm3.
Anions are removing chemical gases and dust particles.
WARRANTY
Warranty period for VIVAX COOL air conditions is 36 months with obligatory annual service performed by authorised servicecentre. Detailed information regarding warranty and list of authorised service centres can be found on www.vivax.com
I FEELDevices with this function have built in sensor on
the remote control. This sensor enables temperature
measuring in a direct vicinity of the remote control and
such information is being sent to the indoor unit which
then starts to heat or cool. Such temperature control
enables precise and more comfortable environment as
well as energy saving. If during heating or cooling mode
remote control registers that the temperature is higher/
lower than default temperature, the device will start
adjusting and creating more comfortable environment.
If during heating/cooling mode the remote control
registers that the temperature is higher/lower from
default temperature, it will automatically shut down the
compressor with the purpose to save energy.
DRY MOULD PROOFIf your device has this function and you turn off the wholedevice, regardless of the mode heating/cooling, indoor
fan will continue to rotate in low speed to dry out internal
components and parts. This function keeps interior clean
and dry and it prevents emergence of mould and odours
CATECHIN FILTERFilter is produced out of durable fibre net that collects
dust form the air and prevents spreading of bacteria and
viruses. Filter efficiency is ≥ 95%.
Filter options
*model ACP-56COFM164GEEI
VIVAX multi split
DV inverter systems
-
8/9/2019 VIVAX cool 2014.pdf
10/36
We reserve the right of eventual printing errors.8
FLOOR
SPLIT SYSTEMS CT-GEEI3.5k W 5.2kW
FLOOR CEILING
SPLIT SYSTEMSCF-GEEI 5.0k W 10.0kW7.0kW
CASSETTE
SPLIT SYSTEM CC-GEEI
3.5kW
11kW
5.0kW
14kW 16kW
DUCT
SPLIT SYSTEMDT-GEEI 7.0kW 10.0kW 11.5W
DUAL SPLIT SYSTEM AEEI2x
2.6kW
Products Overview
14kW 16kW
7kW 10kW
14kW 16kW
Photo Series Capacity
WALL
SPLIT SYSTEM
GEYI 3.5kW 5.3kW
GEEI 5.2kW3.5kW 6.4kW
AELI 2.8kW 5.3kW3.5kW
MOBILE AIR
CONDITIONERSAEH 2.6kW 3.5kW
2.7kW
-
8/9/2019 VIVAX cool 2014.pdf
11/36
We reserve the right of eventual printing errors.9
VIVAX cool 2014.
Photo Series Capacity
M U L T I S P L
I T S Y S T E M S
Wall mounted
indoor unitCIFM-GEEI
2.1kW
3.5kW
2.6kW
5.3kW
Floor mounted
indoor unitCTIFM-GEEI 2.6k W 3.5kW 5.3kW
Cassette
indoor unit
CCIFM-GEEI 3.5kW 4.5kW
Duct
indoor unitsDTIFM-GEEI 5.0kW 7.1kW
Outdoor unit COFM-GEEI5.0kW
8.0kW
7.1kW
12.1kW
Outdoor unit
COFM-GEEI
SUPER FREE
MATCHI
14kW 16kW
-
8/9/2019 VIVAX cool 2014.pdf
12/36
We reserve the right of eventual printing errors.10
High Efficiency
Ionizer
G10 tehnology
1W standbyI feel
Heating operating temperature range -20°C
Cooling operating temperature range -15°C
Condenser and compressor’s heaters
Intelligent defrosting
7-fan speeds indoor unit
Bio filter
●
●
●
●
●
●
●
●
●
●
●
WALL SPLIT SYSTEMDC inverter
GEYI series
ACP-18CH50GEYIACP-12CH35GEYI
Energyefficiencyclass
Model ACP-12CH35GEYI ACP-18CH50GEYI
Capacity Cooling 3500(700-4500) W 5275(1260~6600) WHeating 3650(720~5500) W 5800(1120~6800) W
Refrigerant R410A R410AEnergy efficiency class Cooling A++ A+
Heating A++ AEnergy Efficiency SEER 7.0 5.6
SCOP 4.6 3.8Design load for heating (Pdesignh) 3800 W 4500 WInput power Cooling 900 W 1514 W
Heating 895 W 1600 WAirflow ≤770 m³/h ≤850 m³/hDehumidifying capacity 1.4 L/h 1.8 L/hSound pressure level Indoor unit ≤43 dB(A) ≤48 dB(A)
Outdoor unit ≤50 dB(A) ≤56 dB(A)Sound power level Indoor unit ≤59 dB ≤58 dB
Outdoor unit ≤63 dB ≤65 dBOuter Diameter of Liquid Pipe 1/4” 1/4”Outer Diameter of Gas Pipe 3/8” 1/2”Connection wire 4x1.5 mm² 4x2.5 mm²Power supply ~220-240V/1/50Hz; indoor unitMax. length of pipe 20 m 25 mMax elevation 10 m 10 mStandard length 5 m 5 mAdditional refrigerant 20 g/m 20 g/mWall bracket distance(outdoor) 550 mm 560 mmWorking range -20°C≤T≤43°C -20°C≤T≤43°C
Net dimensions Indoor unit 866x292x209 mm 940×298×200 mmOutdoor unit 899x596x378 mm 955×700×396 mm
Net weight Indoor unit 11.0 kg 13.0 kgOutdoor unit 43.0 kg 45.0 kg
3 Sleep Curves
• Mod 1: indoor temperature automatically rises (when
cooling) or drops (when heating)
• Mod 2: featuring unique refreshment function, the
temperature is automatically adjusted to be a little lower
before you wake up.
• Mod 3: You could design your own sleep curve under DIY
mode.
Time
Temperature
Sleep Curve for Cooling
-
8/9/2019 VIVAX cool 2014.pdf
13/36
We reserve the right of eventual printing errors.11
model: ACP-18CH50GEYI
-
8/9/2019 VIVAX cool 2014.pdf
14/36
We reserve the right of eventual printing errors.12
GEEI series
●
●
●
●
●
●
●
●
●
High Efficiency
Heating operating temperature range -15°C
Cooling operating temperature range -15°C
Intelligent defrosting
G10 tehnology
Ionizer
Bio filter
1W standby
I feel
ACP-22CH65GEEI
WALL SPLIT SYSTEMDC inverter
ACP-18CH50GEEI
Energyefficiencyclass
ACP-12CH35GEEI
ACP-09CH25GEEI
Model ACP-09CH25GEEI ACP-12CH35GEEI ACP-18CH50GEEI ACP-22CH65GEEI
Capacity Cooling 2700 (600-3200) W 3500 (600-3900) W 5275 (1260-6600) W 6450 (2530-6800) WHeating 2800 (800-3600) W 4000 (880-4400) W 5800 (1120-6800) W 7000 (2530-7600) W
Refrigerant R410A R410A R410A R410AEnergy efficiency class Cooling A+ A++ A+ A
Heating A A+ A AEnergy Efficiency SEER 5.6 6.1 5.6 5.1
SCOP 3.8 4.0 3.8 3.8Design load for heating (Pdesignh) 2800 W 3200 W 4500 W 5800 WInput power Cooling 870 W 1170 W 1625 W 2180 W
Heating 900 W 1200 W 1760 W 2220 WAirflow ≤600 m³/h ≤600 m³/h ≤850 m³/h ≤1000 m³/hDehumidifying capacity 0.8 L/h 1.40 L/h 1.8 L/h 2.0 L/hSound pressure level Indoor unit ≤41 dB(A) ≤42 dB(A) ≤48 dB(A) ≤51 dB(A)
Outdoor unit ≤51 dB(A) ≤53 dB(A) ≤56 dB(A) ≤58 dB(A)Sound power level Indoor unit ≤54 dB ≤54 dB ≤58 dB ≤63 dB
Outdoor unit ≤63 dB ≤63 dB ≤63 dB ≤68 dBOuter Diameter of Liquid Pipe 1/4” 1/4” 1/4” 1/4”Outer Diameter of Gas Pipe 3/8” 3/8” 1/2” 5/8”Connection wire 4*1.5 mm ² 4*1.5 mm ² 4*1.5 mm ² 4*1.5 mm ²Power supply ~220-240V/1/50Hz; indoor unitMax. length of pipe 15 m 15 m 25 m 25 mMax elevation 10 m 10 m 10 m 10 mStandard length 5 m 5 m 5 m 5 mAdditional refrigerant 20 g/m 20 g/m 20 g/m 50 g/mWall bracket distance(outdoor) 510 mm 510 mm 560 mm 610 mmWorking range -15°C≤T≤43°C - 15°C≤T≤43°C -15°C≤T≤43°C - 15°C≤T≤43°C
Net dimensions Indoor unit 845X180X275 845X180X275 940×298×200 1007×315×219Outdoor unit 776x540x320 776x540x320 955x700x396 980×427×790
Net weight Indoor unit 9 kg 9 kg 13 kg 14 kgOutdoor unit 28 kg 29 kg 45 kg 60 kg
-
8/9/2019 VIVAX cool 2014.pdf
15/36
We reserve the right of eventual printing errors.13
●
●
●
●
●
●
●
●
●
●
●
●
Bio filter
1W standby
Heating operating temperature
range -15°C
12-fan speeds indoor unit (Quietdesign)
Refrigerant Leakage Detect
Temp compensation
Automatic defrosting
Turbo mode
Sleep mode
24h timer
LED display
Self Diagnosis displaying
WALL SPLIT SYSTEMDC inverter
ACP-09CH25AELIACP-12CH35AELI ACP-18CH50AELI
Energyefficiencyclass
AELI series
Power Factor Correction (PFC) TechnologyWith advanced partial active PFC control, the input
current waveform and voltage waveform get phasesynchronization, more than 97% of the input powersupply is used effectively, which greatly improve power
transformation efficiency.
Model ACP-09CH25AELI ACP-12CH35AELI ACP-18CH50AELI
Capacity Cooling 2638(1284-3218) W 3517(1202-3933) W 5275(1917-5730) WHeating 2931(803-3271) W 3810(1011-3998) W 5569(1386-6225) W
Refrigerant R410A R410A R410AEnergy efficiency class Cooling A A A++
Heating A A AEnergy Efficiency SEER 5.5 5.5 6.5
SCOP 3.8 3.8 3.8Design load for heating (Pdesignh) 2200 W 2700 W 4700 WInput power Cooling 1240 W 1510 W 2200 W
Heating 1170 W 1430 W 2220 WAirflow ≤400 m³/h ≤500 m³/h ≤850 m³/hDehumidifying capacity 1.0 L/h 1.1 L/h 1.7 L/hSound pressure level Indoor unit ≤37 dB(A) ≤40 dB(A) ≤41 dB(A)
Outdoor unit ≤56 dB(A) ≤55 dB(A) ≤58 dB(A)Sound power level Indoor unit ≤55 dB ≤54dB ≤56 dB
Outdoor unit ≤63 dB ≤63dB ≤65 dBOuter Diameter of Liquid Pipe 1/4” 1/4” 1/4”Outer Diameter of Gas Pipe 3/8” 3/8” 1/2”Connection wire 5*1.5 mm ² 5*1.5 mm ² 5*2.5 mm ²Power supply ~220-240V/1/50Hz; outdoor unitMax. length of pipe 25 m 25 m 30 mMax elevation 10 m 10 m 20 mStandard length 5 m 5 m 5 mAdditional refrigerant 15 g/m 15 g/m 15 g/mWall bracket distance(outdoor) 549 mm 549 mm 530 mmWorking range -15°C≤T≤50°C -15°C≤T≤50°C -15°C≤T≤50°C
Net dimensions Indoor unit 710x190x250 mm 790x198x265 mm 920x223x292 mmOutdoor unit 780x250x540 mm 780x250x540 mm 760x285x590 mm
Net weight Indoor unit 6.5 kg 8 kg 11 kgOutdoor unit 29.5 kg 29.5 kg 35 kg
-
8/9/2019 VIVAX cool 2014.pdf
16/36
We reserve the right of eventual printing errors.14
0,5W standby
Memory function (auto restart)
Anti Cool Air design
Automatic defrosting
Dehumidifying
Sleep mode
24h timer
LED displaySelf Diagnosis displaying
●
●
●
●
●
●
●
●
●
MOBILE AIR CONDITIONERSMobile air conditioners
Energyefficiencyclass
AEH series
0.5W Standby
Intelligent on-off technology enables Vivax
products automatically enter energy-saving
mode when on standby mode, cut energy
consumption from conventional 5W to 0.5W
which counts 90% of saving.
Model ACP-09PT25AEH ACP-12PT35AEH
Capacity Cooling 2600 W 3500 WHeating 2500 W 2900 W
Refrigerant R410A R410AEnergy efficiency class Cooling A A
Heating A+ A+Energy Efficiency EER 2.6 2.6
COP 2.6 2.6SEERSCOP
Design load for heating (Pdesignh)Input power Cooling 1010 W 1350 W
Heating 955 W 1130 WAirflow ≤370 m³/h ≤370 m³/hDehumidifying capacity 1.0 L/h 1.2 L/hSound pressure level Indoor unit ≤51 dB(A) ≤51 dB(A)
Outdoor unit
Sound power level Indoor unit ≤64 dB ≤65 dBNet dimensions Indoor unit 467x397x765 mm 467x397x765 mmNet weight Indoor unit 30.5 kg 34 kg
-
8/9/2019 VIVAX cool 2014.pdf
17/36
We reserve the right of eventual printing errors.15
8°C heating
I feel
Heating operating
temperature range -15°CCooling operating temperature range -15°C
Memory function (auto restart)
Dry Mould Proof
Turbo mode
24h timer
Sleep modeLED display
Self Diagnostis displaying
●
●
●
●
●
●
●
●
●
●
●
FLOOR SPLIT SYSTEMSDC inverter
ACP-12CT35GEEI
ACP-18CT50GEEI
Energyefficiencyclass
CT-GEEI series
8°C Heating
Maintain the room temperaturesteadily at 8°C and prevent the roomfrom freezing by heating operation
when nobody is at home for long insevere winter.
Model ACP-12CT35GEEI ACP-18CT50GEEI
Capacity Cooling 3500 (600-3950) W 5200 (1260-6600) W
Heating 3650 (600-4700) W 5500 (1120~6800) WRefrigerant R410A R410AEnergy efficiency class Cooling A++ A+
Heating A AEnergy Efficiency SEER 6.1 5.6
SCOP 3.8 3.8Design load for heating (Pdesignh) 3500 W 5200 WInput power Cooling 1100 W 1760 W
Heating 1100 W 1600 WAirflow ≤600 m³/h ≤650 m³/hDehumidifying capacity 1.2 L/h 1.8 L/hSound pressure level Indoor unit ≤42 dB(A) ≤48 dB(A)
Outdoor unit ≤53 dB(A) ≤56 dB(A)Sound power level Indoor unit ≤54 dB ≤58 dB
Outdoor unit ≤63 dB ≤63 dBOuter Diameter of Liquid Pipe 1/4" 1/4"Outer Diameter of Gas Pipe 3/8" 1/2"Connection wire 4x1.5 mm² 4x1.5 mm²Power supply ~220-240V/1/50Hz; indoor unitMax. length of pipe 20 m 25 mMax elevation 10 m 10 mStandard length 5 m 5 mAdditional refrigerant 20 g/m 20 g/mWall bracket distance(outdoor) 540 mm 560 mmWorking range -15°C≤T≤48°C -15°C≤T≤48°C
Net dimensions Indoor unit 700×215×600 mm 700x215x600 mmOutdoor unit 848×540×320 mm 955×700×396 mm
Net weight Indoor unit 15.0 kg 15.0 kgOutdoor unit 33.0kg 46.0kg
-
8/9/2019 VIVAX cool 2014.pdf
18/36
We reserve the right of eventual printing errors.16
FLOOR CEILING SPLIT SYSTEMDC inverter
Additional wired controler
8°C heating
Heating operating
temperature range -15°C
Low Ambient Cooling
Function
Memory function (auto
restart)
24h timer
1W standby
Sleep mode
LED display
Self Diagnosis displaying
●
●
●
●
●
●
●
●
●
●
Energyefficiencyclass
CF-GEEI series
Model ACP-18CF50GEEI ACP-24CF70GEEI ACP-36CF100GEEI ACP-48CF140GEEI ACP-60CF176GEEI
Capacity Cooling 5000 (1600~5800) W 7000 (2400~8200) W 10000 (3200~11000) W 14000 (6000~14800) W 16000 (6350~16500) W
Heating 5600 (1400~6800) W 8400 (2400~9000) W 12000 (2900~14000) W 16000 (5200-18000) W 17000 (5500~20000) W
Refrigerant R410A R410A R410A R410A R410A
Energy efficiency class Cooling A A A C C
Heating A A A B A
Energy efficiency EER 2.98 2.86
COP 3.52 3.61
SEER 5.1 5.1 5.1SCOP 3.8 3.8 3.8
Design load for heating (Pdesignh) 4500 W 7000 W 9200 W 11800 W 13000 W
Input power Cooling 1550 2180 3500 4800 W 5750 W
Heating 1550 2210 3550 4300 W 4700 W
Airflow ≤1000 m3/h ≤1200 m3/h ≤2000 m3/h ≤2300 m³/h ≤2500 m³/h
Dehumidifying capacity 1.9 L/h 2.2 L/h 3.1 L/h 4.5 L/h 5.0 L/h
Sound pressure level Indoor unit ≤ 42 dB (A) ≤ 47 dB (A) ≤ 53 dB (A) ≤ 56 dB (A) ≤ 58 dB (A)
Outdoor unit ≤ 56 dB (A) ≤ 57 dB (A) ≤ 61 dB (A) ≤ 59 dB (A) ≤ 63 dB (A)
Sound power level Indoor unit ≤ 58 dB ≤ 62 dB ≤ 65 dB ≤ 68 dB ≤ 71 dB
Outdoor unit ≤ 64 dB ≤ 65 dB ≤ 70 dB ≤ 70 dB ≤ 75 dB
Outer Diameter of Liquid Pipe 1/4 " 3/8 " 3/8 " 3/8“ 3/8"
Outer Diameter of Gas Pipe 1/2 " 5/8 " 5/8 " 5/8 " 3/4"
Connection wirepower supply OU: 3*1.5 mm ²;power supply IU: 3*1.0 mm ²;connection wire: 2*0.75 mm ²
power supply OU: 3*2.5 mm ²;power supply IU: 3*1.0 mm ²;connection wire: 2*0.75 mm ²
power supply OU: 3*2.5 mm ²;power supply IU: 3*1.0 mm ²;connection wire: 2*0.75 mm ²
power supply OU: 3*5 mm ²;power supply IU: 3*1.0 mm ²;connection wire: 2*0.75 mm ²
power supply OU: 5*2.5 mm ²;power supply IU: 3*1.0 mm ²;connection wire: 2*0.75 mm ²
Power supply ~220-240V/1/50Hz; indoor & outdoor unit~380~415V; 50Hz;3ph;indoor & outdoor unit
Max. length of pipe 20 m 30 m 30 m 50 m 50 m
Max elevation 15 m 15 m 15 m 30 m 30 m
Standard length 5 m 5 m 5 m 5 m 5 m
Additional refrigerant 30 g/m 60 g/m 60 g/m 60 g/m 60 g/m
Wall bracket distance(outdoor) 560 mm 610 mm 631 mm 572 mm 620 mm
Working range -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C
Net dimensions Indoor unit 1220*225*700 mm 1220*225*700 mm 1420*245*700 mm 1700*245*700 mm 1700*245*700 mm
Outdoor unit 955*396*700 mm 980*427*790 mm 1107*440*1100 mm 958*412*1349 mm 1085*427*1365 mm
Net weight Indoor unit 39 kg 40 kg 48 kg 56 kg 59 kg
Outdoor unit 47 kg 67 kg 92 kg 105 kg 126 kg
Workablewith SZC-16
-
8/9/2019 VIVAX cool 2014.pdf
19/36
We reserve the right of eventual printing errors.17
Additional wired controler8°C heating
Built-in drain pump
Heating operatingtemperature range -15°C
Low Ambient Cooling
Function
Memory function
(auto restart)
24h timer
1W standby
LED display
Self Diagnosis displaying
●
●
●
●
●
●
●
●
●
●
CASSETTE SYSTEMDC inverter
CC-GEEI series
Energyefficiencyclass
Model ACP-12CC35GEEI ACP-18CC50GEEI ACP-24CC70GEEI ACP-36CC100GEEI ACP-42CC140GEEI ACP-48CC140GEEI ACP-60CC176GEEICapacity Cooling 3500 (900-3900) W 5000 (1600~5800) W 7000 (2400~8500) W 10000 (3200~11000) W 11000 (3300~12500) W 14000 (6000~14800) W 16000 (6500~16500) W
Heating 3800 (900-4100) W 5500 (1400~6500) W 8000 (2400~9500) W 12000 (2900~14000) W 12500 (3600~15000) W 16000 (5200~18000) W 17000 (5200~20000) WRefrigerant R410A R410A R410A R410A R410A R410A R410AEnergy efficiency class Cooling A A A A A
Heating A A A A A A
Energy efficiency EER 2.98 2.86
COP 3.52 3.61SEER 5.1 5.1 5.1 5.1 5.1 5.1 5.1SCOP 3.8 3.8 3.8 3.8 3.8
Design load for heating (Pdesignh) 3000 W 4600 W 7200 W 9200 W 9500 W 12000 W 13000 WInput power Cooling 1090 W 1550 W 2180 W 3500 W 3900 W 4600 W 5700 W
Heating 1050 W 1524 W 2210 W 3550 W 3800 W 4500 W 4700 WAirflow ≤ 550 m3/h ≤ 760 m3/h ≤ 1300 m3/h ≤ 1660 m3/h ≤1660 m3/h ≤2300 m3/h ≤2400 m3/hDehumidifying capacity 1.2 L/h 1.8 L/h 2.4 L/h 3.2 L/h 3.7 L/h 4.5L/h 5.0L/hSound pressure level Indoor unit ≤ 47 dB(A) ≤ 47 dB (A) ≤ 47 dB (A) ≤ 53dB (A) ≤ 54dB (A) ≤ 53dB (A) ≤ 55dB (A)
Outdoor unit ≤54 dB(A) ≤ 56 dB (A) ≤ 57 dB (A) ≤ 61dB (A) ≤ 61dB (A) ≤ 59dB (A) ≤ 63dB (A)Sound power level Indoor unit ≤ 57 dB ≤ 60 dB ≤ 62 dB ≤ 64 dB ≤ 64 dB ≤ 64dB ≤ 66dB
Outdoor unit ≤ 62 dB ≤ 64 dB ≤ 65 dB ≤ 68 dB ≤ 70dB ≤ 70dB ≤ 75dBOuter Diameter ofLiquid Pipe
1/4" 1/4" 3/8" 3/8" 3/8" 3/8 " 3/8"
Outer Diameter ofGas Pipe
3/8" 1/2" 5/8" 5/8" 5/8" 5/8 " 3/4"
Connection wire
power supply OU: 3*1.5 mm ²;
power supply IU: 3*1.0 mm ²,connection wire: 2*0.75 mm ²
power supply OU: 3*1.5 mm ²;
power supply IU: 3*1.0 mm ²,connection wire: 2*0.75 mm ²
power supply OU: 3*2.5 mm ²;
power supply IU: 3*1.0 mm ²,connection wire: 2*0.75 mm ²
power supply OU: 3*2.5 mm ²;
power supply IU: 3*1.0 mm ²,connection wire: 2*0.75 mm ²
power supply OU: 3*5 mm ²;
power supply IU: 3*1.0 mm ²,connection wire: 2*0.75 mm ²
power supply OU: 3*5 mm ²;
power supply IU: 3*1.0 mm ²,connection wire: 2*0.75 mm ²
power supply OU: 5*2.5 mm ²;
power supply IU: 3*1.0 mm ²,connection wire: 2*0.75 mm ²
Power supply ~220-240V/1/50Hz; indoor & outdoor unit~380~415V; 50Hz;3ph; indoor& outdoor unit
Max. length of pipe 20m 20m 30m 30m 50m 50m 50mMax elevation 15m 15m 15m 15m 30m 30m 30mStandard length 5m 5m 5m 5m 5m 5m 5mAdditional refrigerant 30g/m 30g/m 60g/m 60 g/m 60g/m 60g/m 60g/mWall bracketdistance(outdoor)
540mm 560mm 610mm 631mm 572mm 572mm 620mm
Working range -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C
Net dimensions Indoor unit 596*592*240 596*592*240 840*780*240 840*892*320 840*892*320 910*842*290 mm 910*842*290 mm
Panel 670*670*65 670*670*65 952*952*65 952*952*65 952*952*65 1040*1040*65 1040*1040*65Outdoor unit 848*320*540 955*396*700 980*427*790 1107*440*1100 958*412*1349 958*412*1349 mm 1085*427*1365 mmNet weight Indoor unit 20 kg 20 kg 26 kg 31 kg 31 kg 43 kg 43 kg
Panel 3.5 kg 3.5 kg 7 kg 7 kg 7 kg 8 kg 8 kgOutdoor unit 34 kg 47 kg 67 kg 92 kg 95 kg 105 kg 126 kg
Workable
with SZC-16
-
8/9/2019 VIVAX cool 2014.pdf
20/36
We reserve the right of eventual printing errors.18
DUCT SYSTEMDC inverter
DT-GEEI series
Additional wired controler
8°C heating
Built-in drain pump (except
model ACP-60DT176GEEI)Heating operating temperature
range -15°C
Low Ambient Cooling Function
Memory function (auto restart)
24h timer
1W standby
LED display
Self Diagnosis displaying
●
●
●
●
●
●
●
●
●
●
Energyefficiency
class
Workablewith SZC-16
Model ACP-24DT70GEEI ACP-36DT100GEEI ACP-42DT140GEEI ACP-48DT140GEEI ACP-60DT176GEEI
Capacity Cooling 7000 (2400~8500) W 10000( 3200~11000) W 11500 (3600~13000) W 14000 (6000~14500) W 16000 (6800~17500) W
Heating 8000 (2400~9500) W 12000 (2900~14000) W 13500 (3900~15000) W 15500 (5200~17000) W 16500 (5300~18800) W
Refrigerant R410A R410A R410A R410A R410A
Energy efficiency class Cooling A A A C C
Heating A A A B A
Energy efficiency EER 2.98 2.86
COP 3.52 3.61
SEER 5.1 5.1 5.1 - -SCOP 3.8 3.8 3.8 - -
Design load for heating (Pdesignh) 7200 W 10400 W 10000 W 11800 W 13000 W
Input power Cooling 2180 W 3500 W 4000 W 4700 W 5600 W
Heating 2210 W 3500 W 3900 W 4400 W 4570 W
Airflow ≤1400 m3/h ≤2000 m3/h ≤2300 m3/h ≤2400 m3/h ≤3000 m3/h
Dehumidifying capacity 2.0 L/h 2.8 L/h 3.2 L/h 4.5 L/h 5.0 L/h
Sound pressure level Indoor unit ≤ 47dB (A) ≤ 53 dB (A) ≤ 53dB (A) ≤ 55 dB (A) ≤ 57 dB (A)
Outdoor unit ≤ 57dB (A) ≤ 61dB (A) ≤ 61dB (A) ≤ 59 dB (A) ≤ 63 dB (A)
Sound power level Indoor unit ≤ 64 dB ≤ 64 dB ≤ 64 dB ≤ 68 dB ≤ 71 dB
Outdoor unit ≤ 65 dB ≤ 68 dB ≤ 70 dB ≤ 70 dB ≤ 75 dB
Outer Diameter of Liquid Pipe 3/8" 3/8" 3/8" 3/8" 3/8"
Outer Diameter of Gas Pipe 5/8" 5/8" 5/8" 5/8" 3/4"
Connection wirepower supply OU: 3*1.5 mm ²;power supply IU: 3*1.0 mm ²,wire: 2*0.75 mm ²
power supply OU: 3*2.5 mm ²;power supply IU: 3*1.0 mm ²,wire: 2*0.75 mm ²
power supply OU: 3*2.5 mm ²;power supply IU: 3*1.0 mm ²,wire: 2*0.75 mm ²
power supply OU: 3*2.5 mm ²;power supply IU: 3*1.0 mm ²,wire: 2*0.75 mm ²
power supply OU: 5*2.5 mm ²;power supply IU: 3*1.0 mm ²,wire: 2*0.75 mm ²
Power supply ~220-240V/1/50Hz; indoor & outdoor unit~380~415V; 50Hz;3ph;indoor & outdoor unit
Max. length of pipe 30 m 30 m 50 m 50 m 50 m
Max elevation 15 m 15 m 30 m 30 m 30 m
Standard length 5 m 5 m 5 m 5 m 5 m
Additional refrigerant 60 g/m 60 g/m 60 g/m 60 g/m 60 g/m
Wall bracket distance(outdoor) 610 mm 631 mm 572 mm 572 mm 620 mm
Working range -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C
Net dimensions Indoor unit 1239*558*268 mm 1226*775*290 mm 1226*775*290 mm 1340*750*350 mm 1340*750*350 mmOutdoor unit 980*427*790 mm 1107*440*1100 mm 958*412*1349 mm 958*412*1349 mm 1085*427*1365 mm
Net weight Indoor unit 34 kg 46 kg 46 kg 56 kg 57 kg
Outdoor unit 68 kg 92 kg 95 kg 105 kg 126 kg
-
8/9/2019 VIVAX cool 2014.pdf
21/36
We reserve the right of eventual printing errors.19
8°C HeatingMaintain the room temperature steadily at 8°C and prevent the room from
freezing by heating operation when nobody is at home for long in severe winter.
-15°C CoolingCooling at -15°C while keep a reliable operation. As the outdoor temperature
changes, the frequency of compressor and the speed of fan adjustus accordingly.
-15°C Heating
Operate finely when heating at -15°C. It is supported by VIVAX’s electricalheating chassis, preheating technology and frequency-adjusting compressor.
Funtions for Low Ambient Temperature
Outdoor units -CC-GEEI/CF-GEEI/DT-GEEI series :
Model ACP-12CC35GEEI ACP-18CC50GEEIACP-18CF50GEEI
ACP-24CF70GEEIACP-24CC70GEEIACP-24DT70GEEI
ACP-36CF100GEEIACP-36CC100GEEIACP-36DT100GEEI
ACP-42CC140GEEIACP-42DT140GEEIACP-48CF140GEEIACP-48CC140GEEIACP-48DT140GEEI
ACP-60CF176GEEIACP-60CC176GEEIACP-60DT176GEEI
Netdimensions 848*320*540 955*396*700 980*427*790 mm 1107*440*1100 mm 958*412*1349 mm 1085*427*1365 mm
Net weight 34 47 68 kg 92 kg 105 kg 126 kg
Wall bracketdistance 540 mm 560 mm 610 mm 631 mm 572 mm 620mm
Power supply ~220-240V/1/50Hz; indoor & outdoor unit ~380~415V; 50Hz;3ph;indoor & outdoor unit
1W STANDBY
-
8/9/2019 VIVAX cool 2014.pdf
22/36
We reserve the right of eventual printing errors.20
LOW AMBIENT COOLING KIT
Allows operation of the unit in cooling modeat low outdoor temperature.
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
DUAL SPLIT SYSTEM with two indoor unitsMulti system
AEEI series
Model ACP-18COFM50AEEI ACP-09CIFM25AEEI
Capacity Cooling 5274(2051~5274) W 2600 W
Heating 5860(2344~6153) W 2800 WRefrigerant R410 R410AEnergy efficiency class Cooling A
Heating A+
Energy Efficiency SEER 5.2SCOP 4.1
Design load for heating (Pdesignh) 5391 WInput power Cooling 1600 W
Heating 1700 WAirflow ≤500 m³/hDehumidifying capacity 0.8 L/hSound pressure level Indoor unit ≤40 dB(A)
Outdoor unit ≤61 dB(A)Sound power level Indoor unit ≤55 dB
Outdoor unit ≤63 dBOuter Diameter of Liquid Pipe 1/4" 1/4"Outer Diameter of Gas Pipe 3/8" 3/8"Connection wire 4*1.0 mm ² 4*1.0 mm ²Power supply ~220-240V/1/50Hz; outdoor unitMax. length of pipe 20 mMax elevation 10 mStandard length 5 mAdditional refrigerant 15 g/mWall bracket distance(outdoor) 560 mmWorking range -15°C≤T≤50°C -15°C≤T≤50°C
Net dimensions Indoor unit 710x190x250 mmOutdoor unit 845x320x700 mmNet weight Indoor unit 6.5 kg
Outdoor unit 48 kgACP-18COFM50AEEI
Energyefficiencyclass
ACP-09CIFM25AEEII Feel (follow me)
Ionizer
24h timerActive carbon filter
Auto restart (memory function)
Sleep mode
Auto Swing
Dust filtar
LED display
Self Diagnosis displaying
ACP-18COFM50AEEIAuto restart (memory function)
Condenser and compressor’s heatersLow voltage start up
Heating operating temperature
range -15°C
Cooling operating temperature
range -15°C
Soft Start
Self Diagnosis displaying
I FEEL (follow me)
The mini sensor in the remote controller
can sense its surrounding temperature, and
transmit the signal back to the indoor unit.
So, the unit can adjust the air flow volume
and temperature accordingly so as to
provide maximum comfort.
d l ACP CIFM AEEI
-
8/9/2019 VIVAX cool 2014.pdf
23/36
We reserve the right of eventual printing errors.21
model: ACP-09CIFM25AEEI
MULTI SPLIT SYSTEM
-
8/9/2019 VIVAX cool 2014.pdf
24/36
We reserve the right of eventual printing errors.22
I feel
Ionizer
1W standby
Memory function (auto restart)Dry Mould Proof
Turbo mode
24h timer
Sleep mode
LED display
Self Diagnosis displaying
●
●
●
●
●
●
●
●
●
●
MULTI SPLIT SYSTEMwall mounted indoor unit - DC inverter
CIFM-GEEI series
Energy
efficiencyclass
IONIZERAnions are taking care of your body by stimulating circulation,improvement of your lungs capacity and preventing airway diseases
(e.g. asthma). Negative ions are eliminating dust and smoke, when
air circulates through the ionizer, anions automatically start to act.
The amount of anions can reach maximum of 1.000.000 cm3. Anions
are removing chemical gases and dust particles.
Model ACP-12CIFM35GEEI ACP-18CIFM50GEEI
Capacity Cooling 3500 W 5300 WHeating 3800 W 5800 W
Refrigerant R410A R410A
Airflow ≤630 m³/h ≤850 m³/h
Dehumidifying capacity 1.4 L/h 1.8 L/h
Sound pressure level Indoor unit ≤42 dB(A) ≤45 dB(A)
Sound power level Indoor unit ≤57 dB ≤60 dB
Outer Diameter of Liquid Pipe 1/4” 1/4”
Outer Diameter of Gas Pipe 3/8” 1/2”
Connection wire 4*0.75 mm² 4*0.75 mm²
Power supply ~220-240V/1/50Hz; outdoor unit
Net dimensions Indoor unit 848x189x274 mm 945x298x208 mm
Net weight Indoor unit 10.0 kg 13.0 kg
Model ACP-07CIFM21GEEI ACP-09CIFM25GEEI
Capacity Cooling 2100 W 2600 W
Heating 2600 W 2800 W
Refrigerant R410A R410A
Airflow ≤500 m³/h ≤500 m³/h
Dehumidifying capacity 0.6 L/h 0.8 L/h
Sound pressure level Indoor unit ≤40 dB(A) ≤40 dB(A)Sound power level Indoor unit ≤55 dB ≤55 dB
Outer Diameter of Liquid Pipe 1/4” 1/4”
Outer Diameter of Gas Pipe 3/8” 3/8”
Connection wire 4*0.75 mm ² 4*0.75 mm ²
Power supply ~220-240V/1/50Hz; outdoor unit
Net dimensions Indoor unit 794x186x265 mm 794x186x265 mm
Net weight Indoor unit 9.0 kg 9.0 kg
I FEEL (follow me)
The mini sensor in the remote controller
can sense its surrounding temperature, and
transmit the signal back to the indoor unit.
So, the unit can adjust the air flow volume
and temperature accordingly so as to
provide maximum comfort.
1W STANDBY
model: ACP 09CIFM25GEEI
-
8/9/2019 VIVAX cool 2014.pdf
25/36
We reserve the right of eventual printing errors.23
model: ACP-09CIFM25GEEI
CTIFM GEEI iMULTI SPLIT SYSTEM
-
8/9/2019 VIVAX cool 2014.pdf
26/36
We reserve the right of eventual printing errors.24
CTIFM-GEEI seriesMULTI SPLIT SYSTEMfloor mounted indoor unit - DC inverter
I feel
1W standby
Memory function (auto restart)Dry Mould Proof
Turbo mode
24h timer
Sleep mode
LED display
Self Diagnosis displaying
●
●
●
●
●
●
●
●
●
Energyefficiencyclass
DRY MOULD PROOF
The fan remains to work after turning off the
device in order to dry up the moisture that
remains in the indoor unit.
Model ACP-09CTIFM25GEEI ACP-12CTIFM35GEEI ACP-18CTIFM50GEEI
Capacity Cooling 2600 W 3500 W 5300 W
Heating 2800 W 3800 W 5800 W
Refrigerant R410A R410A R410A
Airflow 480 m ³/h 550 m ³/h 650 m ³/h
Dehumidifying capacity 0.8 L/h 1.4 L/h 1.8 L/hSound pressure level Indoor unit ≤42 dB(A) ≤42 dB(A) ≤48 dB(A)
Sound power level Indoor unit ≤50 dB ≤52 dB ≤58 dB
Outer Diameter of Liquid Pipe 1/4" 1/4" 1/4"
Outer Diameter of Gas Pipe 3/8" 3/8" 1/2"
Connection wire 4*1.0 mm ² 4*1.0 mm ² 4*1.0 mm ²
Power supply ~220-240V/1/50Hz; outdoor unit
Net dimensions Indoor unit 700x600x215 mm 700x600x215 mm 700x600x215 mm
Net weight Indoor unit 15 kg 15 kg 15 kg
I FEEL (follow me)
The mini sensor in the remote controller
can sense its surrounding temperature, and
transmit the signal back to the indoor unit.
So, the unit can adjust the air flow volume
and temperature accordingly so as to
provide maximum comfort.
model: ACP-18CTIFM50GEEI
-
8/9/2019 VIVAX cool 2014.pdf
27/36
We reserve the right of eventual printing errors.25
MULTI SPLIT SYSTEM CCIFM-GEEI series
-
8/9/2019 VIVAX cool 2014.pdf
28/36
We reserve the right of eventual printing errors.26
MULTI SPLIT SYSTEMcassette indoor unit - DC inverter
Additional wired controler
I feel
1W standbyBuilt-in drain pump
Memory function
(auto restart)
Turbo mode24h timer
Sleep mode
LED display
Self Diagnosis displaying
●
●
●
●
●
●
●
●
●
●
Energyefficiencyclass
CCIFM GEEI series
Workable
with SZC-16
Model ACP-12CCIFM35GEEI ACP-18CCIFM50GEEI
Capacity Cooling 3500 W 4500 W
Heating 4000 W 5000 W
Refrigerant R410A R410A
Airflow ≤600 m³/h ≤600 m³/h
Dehumidifying capacity 1.4 L/h 1.8 L/h
Sound pressure level Indoor unit ≤46 dB(A) ≤46 dB(A)
Sound power level Indoor unit ≤56 dB ≤56 dBOuter Diameter of Liquid Pipe 1/4" 1/4"
Outer Diameter of Gas Pipe 3/8" 1/2"
Connection wire 4*1.0 mm ² 4*1.0 mm ²
Power supply ~220-240V/1/50Hz; outdoor unit
Net dimensions Indoor unit 570x570x230 mm 570x570x230 mm
Panel 650x650x50 mm 650x650x50 mm
Net weight Indoor unit 18 kg 18 kg
Panel 2.5 kg 2.5 kg
I FEEL (follow me)
The mini sensor in the remote controller
can sense its surrounding temperature, and
transmit the signal back to the indoor unit.
So, the unit can adjust the air flow volume
and temperature accordingly so as to
provide maximum comfort.
TURBO MODE
With this function, the air conditioner will
maximize the output of cooling or heating
capacity, make the room cool down or
heat up rapidly, and attain the desired
temperature in the shortest time.
MULTI SPLIT SYSTEM DTIFM-GEEI series
-
8/9/2019 VIVAX cool 2014.pdf
29/36
We reserve the right of eventual printing errors.27
MULTI SPLIT SYSTEM duct indoor units - DC inverter
Additional wired controler
I feel
1W standbyBuilt-in drain pump
Memory function
(auto restart)
Turbo mode24h timer
Sleep mode
LED display
Self Diagnosis displaying
●
●
●
●
●
●
●
●
●
●
Energyefficiencyclass
DTIFM GEEI series
Workable
with SZC-16
Model ACP-18DTIFM50GEEI ACP-24DTIFM70GEEI
Capacity Cooling 5000 W 7100 W
Heating 5500 W 8000 W
Refrigerant R410A R410A
Airflow ≤700 m³/h ≤1000 m³/h
Dehumidifying capacity 1.8 L/h 2.5 L/h
Sound pressure level Indoor unit ≤41 dB(A) ≤42 dB(A)Sound power level Indoor unit ≤50 dB ≤52 dB
Outer Diameter of Liquid Pipe 1/4" 3/8"
Outer Diameter of Gas Pipe 1/2" 5/8"
Connection wire 4*1.0 mm ² 4*1.0 mm ²
Power supply ~220-240V/1/50Hz; outdoor unit
Net dimensions Indoor unit 900x200x615 mm 1100x200x615 mm
Net weight Indoor unit 27 kg 31 kg
I FEEL (follow me)
The mini sensor in the remote controller
can sense its surrounding temperature, and
transmit the signal back to the indoor unit.
So, the unit can adjust the air flow volume
and temperature accordingly so as to
provide maximum comfort.
TURBO MODE
With this function, the air conditioner will
maximize the output of cooling or heating
capacity, make the room cool down or
heat up rapidly, and attain the desired
temperature in the shortest time.
MULTI SPLIT SYSTEM COFM-GEEI series
-
8/9/2019 VIVAX cool 2014.pdf
30/36
We reserve the right of eventual printing errors.28
MULTI SPLIT SYSTEM outdoor unit - DC inverter
Heating operating temperature
range -15°C
Cooling operating temperature
range -15°C (18/24/28COFM) - LACfunction
Cooling operating temperature
range -5°C (41COFM) - LAC
functionCompressor With Electric Heater
(all models)
Chassis With Electric Heater
(models 18/24/28COFM)
Memory function (auto restart)
Automatic Defrosting
●
●
●
●
●
●
●
ACP-18COFM50GEEI ACP-24COFM70GEEI
ACP-28COFM80GEEI
ACP-41COFM121GEEI
Energyefficiencyclass
LOW AMBIENT
COOLING KIT
Allows operation of the
unit in cooling mode at low
outdoor temperature.
Model ACP-18COFM50GEEI ACP-24COFM70GEEI ACP-28COFM80GEEI ACP-41COFM121GEEI
Capacity Cooling 5000(2050~6200) W 7100(2200~10000) W 8000(2200~10000) W 12100(2100~13600) WHeating 5600(2500~6650) W 8500(3600~11000) W 9300(2800~11000) W 13000(2600~14000) W
Refrigerant R410A R410A R410A R410A
Energy efficiency class Cooling A+ A A AHeating A A A A
Energy Efficiency EER 3.37COP 3.66SEER 5.6 5.1 5.1SCOP 3.8 3.8 3.8
Design load for heating (Pdesignh) 4600 W 7000 W 7000 WMaximum number of indoor units 2 3 4 5Input power Cooling 1550 W 2400 W 2490 W 3590 W
Heating 1550 W 2350 W 2580 W 3545 WOutdoor unit ≤56 dB(A) ≤58 dB(A) ≤58 dB(A) ≤54 dB(A)
Outdoor unit ≤63 dB ≤68 dB ≤68 dB ≤64 dBOuter Diameter of Liquid Pipe 1/4" 1/4" 1/4" 4*1/4"+3/8"Outer Diameter of Gas Pipe 3/8" 3/8" 3/8" 2*3/8"+2*1/2"+5/8"Connection wire 3*2.5 mm² 3*2.5 mm² 3*2.5 mm² 3*4.0 mm²Power supply ~220-240V/1/50Hz; outdoor unitMax. length of pipe 20 m 60 m 70 m 80 mMax elevation 10 m 20 m 20 m 25 mStandard length 5 m 5 m 5 m 50 mAdditional refrigerant 20 g/m 20 g/m 20 g/m 22 g/mWall bracket distance(outdoor) 550 mm 560 mm 560 mm 631 mmWorking range -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C -15°C≤T≤48°C
Net dimensions Outdoor unit 955x396x700 mm 980x427x790 mm 980x427x790 mm 1015x440x1100 mmNet weight Outdoor unit 50 kg 69 kg 69 kg 102 kg
COFM GEEI series
Multi split system - combination
-
8/9/2019 VIVAX cool 2014.pdf
31/36
We reserve the right of eventual printing errors.29
Multi split system combination
2 i n d o o r u n i t
2,1 + 2,12,1 + 2,62,1 + 3,52,6 + 2,62,6 + 3,53,5 + 3,5
2,05 2,05 - - 4,1(2,05-4,7)2,30 2,50 - - 4,8(2,05-5,8)2,00 3,50 - - 5,5(2,15-6,3)2,50 2,50 - - 5,0(2,05-6,2)2,50 3,50 - - 6,0(2,15-6,3)3,00 3,00 - - 6,0(2,1-6,2)
A B C D Total
COOLING [kW]
2,25 2,25 - - 4,5(2,5-6,0)2,45 2,75 - - 5,2(2,5-6,6)2,30 3,80 - - 6,1(2,6-6,65)2,80 2,80 - - 5,6(2,5-6,6)2,80 3,80 - - 6,3(2,6-6,65)3,15 3,15 - - 6,3(2,5-6,6 5)
A B C D Total
HEATING [kW]
ACP-18COFM50GEEIUnit
2,90 2,90 - - - 4,8(4,5-8,8)2,90 3,10 - - - 6,0(4,5-8,8)2,90 4,40 - - - 7,3(4,5-8,8)3,15 3,15 - - - 6,3(4,5-8,8 )3,15 4,35 - - - 7,5(4,5-8,8)3,75 3,75 - - - 7,5(4,5-8,8)2,75 6,15 - - - 8,9(4,5-9,9)3,85 6,15 - - - 10,0(4,5-11,0)5,90 5,90 - - - 11,8(4,5-12,5)
2,80 2,80 2,80 - - 8,4(4,5-12,0)2,80 2,80 3,10 - - 8,7(4,5-12,0)2,70 3,00 3,00 - - 8,7(4,5-12,0)2,50 2,50 3,80 - - 8,8(4,5-12,0 )3,00 3,00 3,00 - - 9,0(4,5-12,0)
2,50 2,70 3,70 - - 8,9(4,5-12,0)2,60 2,60 3,70 - - 8,9(4,5-12,0)2,90 2,90 6,00 - - 11,8(4,5-12 ,5)2,60 4,10 4,10 - - 10,8(4,5-11,0)3,10 3,90 3,90 - - 10,9(4,5-11,0)3,15 4,00 5,85 - - 13,0(4,5-13,2)2,40 5,00 5,00 - - 12,4(4,5-14,0)4,30 4,30 4,30 - - 12,9(4,5-14,0)4,00 4,00 5,00 - - 13,0(4,5-14,0)3,14 4,94 4,94 - - 13,0(4,5-14,0)4,34 4,34 4,34 - - 13,0(4,5-14,0)
2,65 2,65 2,65 2,65 - 10,6(4,5-12,0)2,60 2,60 2,60 2,90 - 10,7(4,5-12,0)2,50 2,50 2,90 2,90 - 10,8(4,5-12,0)2,60 2,60 2,60 4,00 - 11,8(4,5-12,5)2,80 3,00 3,00 3,00 - 11,8(4,5-14,0)2,50 2,50 2,90 4,00 - 11,9(4,5-14,0)3,25 3,25 3,25 3,25 - 13,0(4,5-14,0)2,50 2,75 2,75 3,90 - 11,9(4,5-14,0)2,50 2,50 4,00 4,00 - 13,0(4,5-14,0)3,00 3,00 3,00 4,00 - 13,0(4,5-14,0)2,55 2,55 2,55 5,35 - 13,0(4,5-14,0)2,60 2,75 2,75 3,80 - 11,9(4,5-14,0)2,65 2,65 3,85 3,85 - 13,0(4,5-14,0)2,25 2,25 3,45 5,05 - 13,0(4,5-14,0)2,10 2,10 4,40 4,40 - 13,0(4,5-14,0)2,35 3,55 3,55 3,55 - 13,0(4,5-14,0)2,65 3,45 3,45 3,45 - 13,0(4,5-14,0)2,35 2,85 2,85 4,95 - 13,0(4,5-14,0)2,10 2,70 4,10 4,10 - 13,0(4,5-14,0)3,25 3,25 3,25 3,25 - 13,0(4,5-14,0)2,70 2,70 2,70 4,90 - 13,0(4,5-14,0)2,55 2,55 3,95 3,95 - 13,0(4,5-14,0)
2,60 2,60 2,60 2,60 2,60 13,0(4,5-14,0)2,55 2,55 2,55 2,55 2,80 13,0(4,5-14,0)2,50 2,50 2,50 2,75 2,75 13,0(4,5-14,0)2,35 2,35 2,75 2,75 2,75 13,0(4,5-14,0)
2,59 2,59 2,59 2,59 2,59 13,0(4,5-14,0)2,40 2,40 2,40 2,40 3,40 13,0(4,5-14,0)2,21 2,21 2,21 3,16 3,16 13,0(4,5-14,0)2,06 2,06 2,96 2,96 2,96 13,0(4,5-14,0)1,96 2,76 2,76 2,76 2,76 13,0(4,5-14,0)2,60 2,60 2,60 2,60 2,60 13,0(4,5-14,0)2,41 2,41 2,41 2,41 3,36 13,0(4,5-14,0)2,36 2,36 2,36 2,94 2,94 13,0(4,5-14,0)2,06 2,06 2,94 2,94 2,94 13,0(4,5-14,0)2,16 2,71 2,71 2,71 2,71 13,0(4,5-14,0)2,60 2,60 2,60 2,60 2,60 13,0(4,5-14,0)2,26 2,26 2,26 2,26 3,96 13,0(4,5-14,0)2,06 2,06 2,06 3,36 3,36 13,0(4,5-14,0)2,11 2,11 2,11 2,76 3,91 13,0(4,5-14,0)2,10 2,10 2,10 3,45 3,45 13,0(4,5-14,0)1,96 1,96 2,61 2,61 3,86 13,0(4,5-14,0)2,06 2,46 2,46 2,46 3,56 13,0(4,5-14,0)
A B C D E Total
2,30 2,30 - - - 4,6(3,5-8,0)2,30 2,50 - - - 4,8(3,5-8,0)2,30 3,50 - - - 5,8(3,5-8,0)2,50 2,50 - - - 5,5(3,5-8,0)2,50 3,50 - - - 6,0(3,5-9,0)3,50 3,50 - - - 7,0(3,5-9,0)2,20 4,90 - - - 7,1(3,5-9,0)3,10 4,90 - - - 8,0(3,5-9,0)4,75 4,75 - - - 9,5(3,5-11,0)
2,30 2,30 2,30 - - 6,9(3,5-9,0 )2,25 2,25 2,50 - - 7,0(3,5-9,0)2,20 2,45 2,45 - - 7,1(3,5-9,0)2,00 2,00 3,10 - - 7,1(3,5-9,0)2,40 2,40 2,40 - - 7,2(3,5-9,0)
2,00 2,10 3,00 - - 7,1(3,5-9,0)2,15 2,15 3,00 - - 7,3(3,5-9,0)2,35 2,35 4,80 - - 9,5(3,5-11,0)2,10 3,30 3,30 - - 8,7(3,5-9,6)2,50 3,10 3,10 - - 8,7(3,5-9,6 )2,50 3,20 4,70 - - 10,4(3,5-12 ,2)2,10 4,40 4,40 - - 11,6(3,5-13 ,6)3,50 3,50 3,50 - - 10,5(3,5-12 ,2)3,20 3,20 4,00 - - 10,4(3,5-12 ,2)2,80 4,40 4,40 - - 11,6(3,5-13,6)3,90 3,90 3,90 - - 11,7(3,5-13,6)
2,15 2,15 2,15 2,15 - 8,6(3,5-9,6)2,10 2,10 2,10 2,30 - 8,6(3,5-9,6)2,00 2,00 2,30 2,30 - 8,6(3,5-9,6)2,10 2,10 2,10 3,20 - 9,5(3,5-11,0)2,30 2,40 2,40 2,40 - 9,5(3,5-11,0)2,00 2,00 2,30 3,20 - 9,5(3,5-11,0)2,60 2,60 2,60 2,60 - 10,4(3,5-12,2)2,00 2,20 2,20 3,10 - 9,5(3,5-11,0)2,00 2,00 3,20 3,20 - 10,4(3,5-12,2)2,40 2,40 2,40 3,20 - 10,4(3,5-12,2)2,30 2,30 2,30 4,70 - 11,6(3,5-13,6)2,00 2,20 2,20 3,10 - 9,5(3,5-11,0)2,10 2,10 3,10 3,10 - 10,4(3,5-12,2)2,00 2,00 3,10 4,50 - 11,6(3,5-13,6)1,90 1,90 3,90 3,90 - 11,6(3,5-13,6)2,00 3,20 3,20 3,20 - 11,6(3,5-13,6)2,30 3,10 3,10 3,10 - 11,6(3,5-13,6)2,10 2,55 2,55 4,40 - 11,6(3,5-13,6)1,90 2,40 3,65 3,65 - 11,6(3,5-13,6)2,90 2,90 2,90 2,90 - 11,6(3,5-13,6)2,45 2,45 2,45 4,25 - 11,6(3,5-13,6)2,30 2,30 3,50 3,50 - 11,6(3,5-13,6)
2,08 2,08 2,08 2,08 2,08 10,4(3,5-12,2)2,05 2,05 2,05 2,05 2,20 10,4(3,5-12,2)2,00 2,00 2,00 2,20 2,20 10,4(3,5-12,2)1,90 1,90 2,20 2,20 2,20 10,4(3,5-12,2)
2,30 2,45 2,45 2,45 2,45 12,1(3,5-13,6)1,95 1,95 1,95 1,95 2,60 10,4(3,5-12,2)2,10 2,10 2,10 2,90 2,90 12,1(3,5-13,6)2,00 2,00 2,70 2,70 2,70 12,1(3,5-13,6)1,90 2,55 2,55 2,55 2,55 12,1(3,5-13,6)2,42 2,42 2,42 2,42 2,42 12,1(3,5-13,6)2,25 2,25 2,25 2,25 3,10 12,1(3,5-13,6)2,20 2,20 2,20 2,75 2,75 12,1(3,5-13,6)2,00 2,00 2,70 2,70 2,70 12,1(3,5-13,6)2,10 2,50 2,50 2,50 2,50 12,1(3,5-13,6)2,42 2,42 2,42 2,42 2,42 12,1(3,5-13,6)2,10 2,10 2,10 2,10 3,70 12,1(3,5-13,6)2,00 2,00 2,00 3,05 3,05 12,1(3,5-13,6)2,00 2,00 2,00 2,55 3,55 12,1(3,5-13,6)2,00 2,00 2,00 3,05 3,05 12,1(3,5-13,6)1,85 1,85 2,45 2,45 3,50 12,1(3,5-13,6)1,85 2,35 2,35 2,35 3,20 12,1(3,5-13,6)
A B C D E Total
2 i n d o o r u n i t
3 i n d o o r u n i t
4 i n d o o r u n i t
2,1 + 2,12,1 + 2,62,1 + 3,52,6 + 2,62,6 + 3,53,5 + 3,52,6 + 5,03,5 + 5,05,0 + 5,0 2,1+ 2,1 + 2,12,1 + 2,1 + 2,62,1 + 2,6 + 2,62,1 + 2,1 + 3,52,6 + 2,6 + 2,6
2,1 + 2,6 + 3,52,6 + 2,6 + 3,52,6 + 2,6 + 5,02,1 + 3,5 + 3,52,6 + 3,5 + 3,52,6 + 3,5 + 5,02,6 + 5,0 + 5,03,5 + 3,5 + 3,53,5 + 3,5 + 5,03,5 + 5,0 + 5,0
5,0 + 5,0 + 5,0
2,1 + 2,1 + 2,1 + 2,12,1 + 2,1 + 2,1 + 2,62,1 + 2,1 + 2,6 + 2,62,1 + 2,1 + 2,1 + 3,52,1 + 2,6 + 2,6 + 2,62,1 + 2,1 + 2,6 + 3,52,6 + 2,6 + 2,6 + 2,6
2,1 + 2,6 + 2,6 + 3,52,1 + 2,1 + 3,5 + 3,52,6 + 2,6 + 2,6 + 3,52,6 + 2,6 + 2,6 + 5,02,1 + 2,6 + 3,5 + 3,52,6 + 2,6 + 3,5 + 3,52,6 + 2,6 + 3,5 + 5,02,6 + 2,6 + 5,0 + 5,02,1 + 3,5 + 3,5 + 3,52,6 + 3,5 + 3,5 + 3,52,6 + 3,5 + 3,5 + 5,02,6 + 3,5 + 5,0 + 5,03,5 + 3,5 + 3,5 + 3,53,5 + 3,5 + 3,5 + 5,03,5 + 3,5 + 5,0 + 5,0
2,1 + 2,1 + 2,1 + 2,1 + 2,12,1 + 2,1 + 2,1 + 2,1 + 2,62,1 + 2,1 + 2,1 + 2,6 + 2,62,1 + 2,1 + 2,6 + 2,6 + 2,6
2,1 + 2,6 + 2,6 + 2,6 + 2,62,1 + 2,1 + 2,1 + 2,1 + 3,52,1 + 2,1 + 2,1 + 3,5 + 3,52,1 + 2,1 + 3,5 + 3,5 + 3,52,1 + 3,5 + 3,5 + 3,5 + 3,52,6 + 2,6 + 2,6 + 2,6 + 2,62,6 + 2,6 + 2,6 + 2,6 + 3,52,6 + 2,6 + 2,6 + 3,5 + 3,52,6 + 2,6 + 3,5 + 3,5 + 3,52,6 + 3,5 + 3,5 + 3,5 + 3,53,5 + 3,5 + 3,5 + 3,5 + 3,52,6 + 2,6 + 2,6 + 2,6 + 5,02,6 + 2,6 + 2,6 + 5,0 + 5,02,6 + 2,6 + 2,6 + 3,5 + 5,02,6 + 2,6 + 2,6 + 5,0 + 5,02,6 + 2,6 + 3,5 + 3,5 + 5,02,6 + 3,5 + 3,5 + 3,5 + 5,0
COOLING [kW] HEATING [kW]
ACP-41COFM121GEEIUnit
5 i n d o o r u n i t
2
i n d o o r u
n i t
2,1 + 2,12,1 + 2,6
2,1 + 3,52,6 + 2,62,6 + 3,53,5 + 3,52,1 + 5,02,6 + 5,0
2,1+ 2,1 + 2,12,1 + 2,1 + 2,62,1 + 2,6 + 2,62,1 + 2,1 + 3,52,6 + 2,6 + 2,62,1 + 2,6 + 3,52,6 + 2,6 + 3,52,1 + 3,5 + 3,52,6 + 3,5 + 3,53,5 + 3,5 +3,5
2,30 2,30 - - 4,6(2,3-7,8)2,30 2,50 - - 4,8(2,3-7,8)
2,20 3,60 - - 5,8(2,1-8,0)2,50 2,50 - - 5,0(2,0-7,8)2,60 3,60 - - 6,2(2,1-8,0)3,50 3,50 - - 7,0(2,2-8,2)2,00 5,00 - - 7,0(2,2-8,2)2,30 4,70 - - 7,0(2,3-8,2)
2,30 2,30 2,30 - 6,9(2,2-9,0)2,25 2,25 2,50 - 7,0(2,2-9,2)2,20 2,45 2,45 - 7,1(2,2-9,4)2,00 2,00 3,10 - 7,1(2,2-9,4)2,36 2,36 2,36 - 7,1(2,2-9,5)2,00 2,15 2,95 - 7,1(2,2-9,5)2,10 2,10 2,90 - 7,1(2,2-9,5)1,90 2,60 2,60 - 7,1(2,2-9,6)1,90 2,60 2,60 - 7,1(2,2-9,6)2,36 2,36 2,36 - 7,1(2,2-9,6)
A B C D Total
3,00 3,00 - - 6,0(3,0-8,0)3,00 3,20 - - 6,2(2,5-8,5)
3,00 4,00 - - 7,0(3,4-9,0)3,20 3,20 - - 6,4(3,2-8,5)3,20 4,00 - - 7,2(3,5-9,3)3,85 3,85 - - 7,7(3,5-9,5)2,20 5,50 - - 7,7(3,6-9,6)2,60 5,10 - - 7,7(3,7-9,9)
2,70 2,70 2,70 - 8,1(3,5-9,9)2,50 2,50 3,10 - 8,1(3,5-9,9)2,40 3,05 3,05 - 8,5(3,6-9,9)2,30 2,30 3,90 - 8,5(3,7-9,9)2,85 2,85 2,85 - 8,5(3,7-9,9)2,10 2,75 3,65 - 8,5(3,7-9,9)2,55 2,55 3,40 - 8,5(3,8-9,9)2,00 3,25 3,25 - 8,5(3,8-9,9)2,20 3,05 3,05 - 8,5(3,8-9,9)2,85 2,85 2,85 - 8,5(3,8-9,9)
A B C D Total
ACP-24COFM70GEEI
Unit
3 i n d o o r u n i t
2
i n d o o r u n i t 2,1 + 2,1
2,6 + 3,53,5 + 3,52,6 + 5,03,5 + 5,05,0 + 5,0
2,1+ 2,1 + 2,12,1 + 2,1 + 2,62,1 + 2,6 + 2,62,6 + 2,6 + 2,62,6 + 2,6 + 3,52,6 + 3,5 + 3,53,5 + 3,5 + 3,52,6 + 2,6 + 5,0
2,6 + 3,5 + 5,03,5 + 5,0 + 5,0
2,1 + 2,1 + 2,1 + 2,12,1 + 2,1 + 2,1 + 2,62,1 + 2,1 + 2,6 + 2,62,1 + 2,1 + 2,1 + 3,52,1 + 2,6 + 2,6 + 2,62,1 + 2,1 + 2,6 + 3,52,6 + 2,6 + 2,6 + 2,62,1 + 2,6 + 2,6 + 3,52,1 + 2,1 + 3,5 + 3,52,6 + 2,6 + 2,6 + 3,52,1 + 2,6 + 3,5 + 3,52,6 + 2,6 + 3,5 + 3,52,1 + 3,5 + 3,5 + 3,52,6 + 3,5 + 3,5 + 3,5
2,50 2,50 - - 5,0(2,2-6,7)2,50 3,50 - - 6,0(2,2-7,8)3,50 3,50 - - 7,0(2,7-8,2)2,60 4,50 - - 7,1(2,7-9,5)3,10 4,00 - - 7,1(2,7-9,5)3,60 3,60 - - 7,1(2,7-9,5)
2,30 2,30 2,30 - 6,9(2,2-9,0)2,25 2,25 2,50 - 7,0(2,2-9,2)2,20 2,45 2,45 - 7,1(2,2-9,4)2,36 2,36 2,36 - 7,1(2,2-9,5)2,10 2,10 2,90 - 7,1(2,2-9,5)1,90 2,60 2,60 - 7,1(2,2-9,6)2,36 2,36 2,36 - 7,1(2,2-9,6)2,20 2,20 2,70 - 7,1(2,2-9,6)
2,10 2,30 2,70 - 7,1(2,2-9,6)2,30 2,30 2,50 - 7,1(2,2-9,6)
1,90 1,90 1,90 1,90 7,6(2,2-9,6)1,95 1,95 1,95 2,15 8,0(2,2-9,6)1,90 1,90 2,10 2,10 8,0(2,2-9,6)1,75 1,75 1,75 2,75 8,0(2,2-9,6)1,85 2,05 2,05 2,05 8,0(2,2-9,6)1,70 1,70 1,85 2,75 8,0(2,2-9,6)2,00 2,00 2,00 2,00 8,0(2,2-9,6)1,55 1,85 1,85 2,75 8,0(2,2-9,6)1,70 1,70 2,30 2,30 8,0(2,2-9,6)1,75 1,75 1,75 2,75 8,0(2,2-9,6)1,40 2,00 2,30 2,30 8,0(2,2-9,6)1,50 1,50 2,50 2,50 8,0(2,2-10,0)1,40 2,20 2,20 2,20 8,0(2,2-10,0)1,70 2,10 2,10 2,10 8,0(2,2-10,0)
A B C D Total
3,20 3,20 - - 6,2(2,5-8,2)3,20 4,00 - - 7,2(2,5-8,5)3,90 3,90 - - 7,8(3,0-9,3)2,90 5,00 - - 7,9(3,0-9,3)3,60 4,50 - - 8,1(3,1-9,9)3,90 3,90 - - 7,8(3,0-9,3)
2,70 2,70 2,70 - 8,1(3,1-9,9)2,60 2,60 2,80 - 8,1(3,1-9,9)2,40 2,85 2,85 - 8,1(3,1-9,9)2,70 2,70 2,70 - 8,1(3,1-9,9)2,50 2,50 3,10 - 8,1(3,1-9,9)2,20 3,05 3,05 - 8,3(3,1-9,9)2,85 2,85 2,85 - 8,5(3,1-9,9)2,35 2,35 3,40 - 8,1(3,1-9,9)
2,20 2,70 3,20 - 8,1(3,1-9,9)1,62 3,24 3,24 - 8,1(3,1-9,9)
2,30 2,30 2,30 2,30 9,2(3,3-11,0)2,25 2,25 2,25 2,55 9,3(3,3+11,0)2,10 2,10 2,55 2,55 9,3(3,3-11,0)2,10 2,10 2,10 3,00 9,3(3,3-11,0)2,10 2,40 2,40 2,40 9,3(3,3-11,0)2,20 2,20 2,20 2,80 9,4(3,3-11,0)2,35 2,35 2,35 2,35 9,4(3,3-11,0)2,10 2,30 2,30 2,90 9,6(3,3-11,0)2,10 2,30 2,30 2,90 9,6(3,3-11,0)2,20 2,20 2,20 3,00 9,6(3,3-11,0)2,00 2,20 2,70 2,70 9,6(3,3-11,0)2,10 2,10 2,70 2,70 9,6(3,3-11,0)2,10 2,50 2,50 2,50 9,6(3,3-11,0)1,80 2,60 2,60 2,60 9,6(3,3-11,0)
A B C D Total
ACP-28COFM80GEEIUnit
3 i n d o o r u n i t
4 i n d o o r u n i t
MULTI SPLIT SYSTEM - SUPER FREE MATCH
COFM-GEEI series
-
8/9/2019 VIVAX cool 2014.pdf
32/36
We reserve the right of eventual printing errors.30
Heating operating temperature range -15°C
Compressor With Electric Heater
Memory function (auto restart)Automatic Defrosting
Workable with SZC-16
●
●
●
●
●
Workable
with SZC-16
outdoor unit - DC inverter
Model ACP-48COFM140GEEI ACP-56COFM164GEEI
Capacity Cooling 14000 (1000-16000) W 16000 (1000-18000) WHeating 16000 (1200-17400) W 18000 (1200-19000) W
Refrigerant R410A R410AEnergy Efficiency EER 2.90 2.80
COP 3.22 3.5Maximum number of indoor units 8 9Input power Cooling 4400 W 5000 W
Heating 4250 W 4700 WOutdoor unit ≤58 dB(A) ≤58 dB(A)
Sound power level Indoor unitOutdoor unit ≤68 dB(A) ≤68 dB(A)Outer Diameter of Liquid Pipe 3/8" 3/8"Outer Diameter of Gas Pipe 5/8" 3/4"Connection wire 5*2.5 mm² 5*2.5 mm²Power supply ~380~415V; 50Hz;3ph; outdoor unitMax. length of pipe 135 m 145 mMax elevation 30 m 30 mStandard length 30 m 30 mAdditional refrigerant 22 g/m (1/4”) + 50 g/m (3/8”) 22 g/m (1/4”) + 50 g/m (3/8”)Wall bracket distance(outdoor) 572 mm 572 mm
Working range -15°C≤T≤48°C -15°C≤T≤48°CNet dimensions Outdoor unit 900×1345×340 mm 900×1345×340 mmNet weight Outdoor unit 116 kg 116 kg
ACP-48COFM140GEEIACP-56COFM164GEEI
Distributor box
-
8/9/2019 VIVAX cool 2014.pdf
33/36
We reserve the right of eventual printing errors.31
If two or three BU modules used, Y-type branch pipe of FQ01A/A will be chosen.
FQ01A/A (Gas pipe)FQ01A/A (Liquid pipe)
Smart Zone Controller SZC-16
Branch pipe
This smart zone controller is intended for multi VRF units and CF/CC/DT/CCIFM/DTIFM-
GEEI type units, capable of controlling up to 3 sets of multi VRF units and multi sets of
duct/cassette type units with maximum 16 indoor units.
Through this smart zone controller, it is available to view and control those running
parameters of the indoor unit, including on/off, running mode, fan speed etc, and also
perform the single control and centralized control, further, it also can set the weekly
timer and long-distance shielding to realize convenient control to the air conditioning
system.
a. Single control: it is intended to control the runningparameters of a designated indoor unit individually.
b. Centralized control: it is intended to control the running
parameters of all indoor units at the same time.
c. Shielding under single or centralized control: it is intended
to shield the running parameter of the indoor unit.
d. Weekly timer under single or centralized control: it is
intended to set when to start/stop the unit through long-
distance control.
e. Clock: it is intended to set and display the weekday, hour
and minute.
The outdoor unit of ACP-48COFM140GEEI and ACP-56COFM164GEEI must only adopt
the BU modules in the following table.
Model DB-3IDUB-K DB-5IDUB-K
Maximum numbers of connectable indoor units 3 5
Power Supply V-Ph-Hz 220~240-1-50
Connection port tooutdoor unit
Gas pipe(inner diameter) inch 5/8" 5/8"Liquid pipe(inner diameter) inch 3/8" 3/8"
Connection Method Flare Flare
Connection port toindoor unit
Gas pipe(inner diameter) 3/8" 3/8"
Liquid pipe(inner diameter) 1/4" 1/4"
Connection Method Flare Flare
Drainage pipeExternal dia. mm Φ31 Φ31 mm Φ31 Φ31
Thickness mm 3 3
Dimension(WxDxH)
Outline mm 617×410×193
Package mm 676×473×275
Net weight/Gross weight kg 8/10 9/11
MULTI SPLIT SYSTEM - SUPER FREE MATCH COFM-GEEI series
-
8/9/2019 VIVAX cool 2014.pdf
34/36
We reserve the right of eventual printing errors.32
Outdoor unit
L1
H1
1A
A B C
BU1 BU2
BU31B 1C 2A 2B 2C
H2
L2 L3
L5
H3
H4
3A
3B
L4 The 1st branch
The 2nd
branch
Indoor unit A
A
B
B
C
The sorts The pipes Length (m)
Maximumallowable length
Between outdoor unit and BU L1+L2+L3+L4+L5 ≤55
Total length betweenindoor unit and BU
ACP-48COFM140GEEI1A+1B+1C+2A+2B+2C+ 3A+3B
≤80
ACP-56COFM164GEEI ≤90
Between indoor unit and BU module 1A;1B;1C;2A;2B;2C;3A;3B ≤15
Between indoor unit and the 1st branch L4+1B;L2+L5+2A;L2+L3+3B ≤40
Maximumallowable length
Between outdoor and indoor units H1 ≤30
Between outdoor units and BU H2 ≤30
Between BU and BU modules H3 ≤15
Between indoor and indoor units H4 ≤15
Minimum allowable lengthBetween outdoor and the 1st branch L1 ≥5
Between BU and the branch L3;L4;L5 as possible as short
Allowable Length/Height Differenceof Refrigerant Piping
MULTI SPLIT SYSTEM - SUPER FREE MATCH - combination
-
8/9/2019 VIVAX cool 2014.pdf
35/36
We reserve the right of eventual printing errors.33
T w o u n i t s 2.1+3.5 2.6+6.2 3.5+7.0 6.2+6.2
2.1+6.2 2.6+7.0 5.3+3.5 6.2+7.0
2.1+7.0 3.5+5.3 3.5+6.2 7.0+7.0
2.6+3.5 3.5+6.2 5.3+7.0
T h r e e u n i t s
2.1+2.1+5.3 2.1+5.3+5.3 2.6+3.5+3.5 3.5+3.5+3.5 5.3+5.3+5.3
2.1+2.1+6.2 2.1+5.3+6.2 2.6+3.5+5.3 3.5+3.5+5.3 5.3+5.3+6.2
2.1+2.1+7.0 2.1+5.3+7.0 2.6+3.5+6.2 3.5+3.5+6.2 5.3+5.3+7.0
2.1+2.6+3.5 2.1+6.2+6.2 2.6+3.5+7.0 3.5+3.5+7.0 5.3+6.2+6.2
2.1+2.6+5.3 2.1+6.2+7.0 2.6+5.3+5.3 3.5+5.3+5.3 5.3+6.2+7.0
2.1+2.6+6.2 2.1+7.0+7.0 2.6+5.3+6.2 3.5+5.3+6.2 5.3+7.0+7.0
2.1+2.6+7.0 2.6+2.6+3.5 2.6+5.3+7.0 3.5+5.3+7.0 6.2+6.2+6.2
2.1+3.5+3.5 2.6+2.6+5.3 2.6+6.2+6.2 3.5+6.2+6.2 6.2+6.2+7.0
2.1+3.5+3.5 2.6+2.6+6.2 2.6+6.2+7.0 3.5+6.2+7.0 6.2+7.0+7.0
2.1+3.5+6.2 2.6+2.6+7.0 2.6+7.0+7.0 3.5+7.0+7.0 7.0+7.0+7.0
F o u r u n i t s
2.1+2.1+2.1+2.1 2.1+2.1+6.2+7.0 2.1+3.5+3.5+7.0 2.6+2.6+3.5+ 6.2 2.6+5.3+5.3+7.0
2.1+2.1+2.1+2.6 2.1+2.1+7.0+7.0 2.1+3.5+3.5+5.3 2.6+2.6+3.5+7.0 2.6+5.3+6.2+6.2
2.1+ 2.1+2.1+3.5 2.1+2.6+2.6+2.6 2.1+3.5+5.3+6.2 2.6+2.6+5.3+5.3 2.6+5.3+6.2+7.0
2.1+2.1+2.1+5.3 2.1+2.6+2.6+3.5 2.1+3.5+5.3+7.0 2.6+2.6+5.3+6.2 2.6+6.2+6.2+6.2
2.1+2.1+2.1+6.2 2.1+2.6+2.6+5.3 2.1+3.5+6.2+6.2 2.6+2.6+5.3+7.0 3.5+3.5+3.5+3.5
2.1+2.1+2.1+7.0 2.1+2.6+2.6+6.2 2.1+3.5+6.2+7.0 2.6+2.6+6.2+6.2 3.5+3.5+3.5+5.3
2.1+2.1+2.6+2.6 2.1+2.6+2.6+7.0 2.1+5.3+5.3+5.3 2.6+2.6+6.2+7.0 3.5+3.5+3.5+6.2
2.1+2.1+2.6+ 2.6 2.1+2.6+3.5+3.5 2.1+3.5+3.5+6.2 2.6+2.6+7.0+7.0 3.5+3.5+3.5+7.0
2.1+2.1+2.6+3.5 2.1+2.6+3.5+5.3 2.1+3.5+3.5+7.0 2.6+3.5+3.5+3.5 3.5+3.5+5.3+5.3
2.1+2.1+2.6+5.3 2.1+2.6+3.5+6.2 2.1+5.3+6.2+6.2 2.6+3.5+3.5+3.5 3.5+3.5+ 5.3+6.2
2.1+2.1+2.6+6.2 2.1+2.6+3.5+7.0 2.1+5.3+6.2+7.0 2.6+3.5+3.5+6.2 3.5+3.5+3.5+7.0
2.1+2.1+2.6+7.0 2.1+2.6+5.3+5.3 2.1+5.3+7.0+7.0 2.6+3.5+3.5+7.0 3.5+3.5+6.2+ 6.22.1+2.1+3.5+3.5 2.1+2.6+5.3+6.2 2.1+6.2+6.2+6.2 2.6+3.5+5.3+5.3 3.5+3.5+6.2+7.0
2.1+2.1+3.5+3.5 2.1+ 2.6+5.3+7.0 2.6+2.6+2.6+2.6 2.6+3.5+5.3+6.2 3.5+3.5+7.0+7.0
2.1+2.1+3.5+6.2 2.1+2.6+6.2+6.2 2.6+ 2.6+2.6+3.5 2.6+3.5+5.3+7.0 3.5+5.3+5.3+5.3
2.1+2.1+3.5+7.0 2.1+2.6+6.2+7.0 2.6+2.6+2.6+5.3 2.6+3.5+6.2+6.2 3.5+5.3+5.3+6.2
2.1+2.1+5.3+5.3 2.1+2.6+ 7.0+7.0 2.6+2.6+2.6+6.2 2.6+3.5+6.2+7.0 3.5+5.3+5.3+7.0
2.1+2.1+5.3+6.2 2.1+3.5+3.5+3.5 2.6+2.6+ 2.6+7.0 2.6+3.5+7.0+7.0 3.5+5.3+6.2+6.2
2.1+2.1+5.3+7.0 2.1+3.5+3.5+ 3.5 2.6+2.6+3.5+3.5 2.6+5.3+5.3+5.3 5.3+5.3+5.3+5.3
2 .1+ 2. 1+ 6.2 +6 .2 2. 1+ 3. 5+ 3. 5+ 6. 2 2. 6+ 2. 6+ 3. 5+ 3. 5 2. 6+ 3. 5+ 3. 5+ 6. 2
F i v e u n i t s
2.1-2.1+2.1+2.1+2.1 2.1+2.1+2.6+2.6+3.5 2.1+2.1+5.3+5.3+5.3 2.1+2.6+3.5+5.3+7.0 2.6+2.6+2.6+6.2+7.0
2.1+2.1+2.1+2.1+2.6 2.1+2.1+2.6+2.6+3.5 2.1+2.1+5.3+5.3+6.2 2.1+2.6+3.5+6.2+6.2 2.6+2.6+3.5+3.5+3.5
2.1+2.1+2.1+2.1+3.5 2.1+2.1+2.6+2.6+6.2 2.1+2.6+2.6+2.6+2.6 2.1+2.6+5.3+5.3+5.3 2.6+2.6+3.5+3.5+5.3
2.1+2.1+2.1+2.1+5.3 2.1+2.1+2.6+2.6+7.0 2.1+2.6+2.6+2.6+3.5 2.1+3.5+3.5+3.5+3.5 2.6+2.6+3.5+3.5+6.2
2.1+2.1+2.1+2.1+6.2 2.1+2.1+2.6+3.5+3.5 2.1+2.6+2.6+2.6+5.3 2.1+3.5+3.5+3.5+5.3 2.6+2.6+3.5+3.5+7.02.1+2.1+2.1+2.1+2-1 2.1+2.1+2.6+3.5+5.3 2.1+2.6+2.6+2.6+6.2 2.1+3.5+3.5+3.5+6.2 2.6+2.6+3.5+5.3+5.3
2.1+2.1+2.1+2.6+2.6 2.1+2.1+2.6+3.5+6.2 2.1+2.6+2.6+2.6+7.0 2.1+3.5+3.5+3.5+7.0 2.6+2.6+3.5+5.3+6.2
2.1+2.1+2.1+2.6+3.5 2.1+2.1+2.6+3.5+7.0 2.1+2.6+2.6+3.5+3.5 2.1+3.5+3.5+5.3+5.3 2.6+2.6+3.5+5.3+7.0
2.1+2.1+2.1+2.6+5.3 2.1+2.1+2.6+5.3+5.3 2.1+2.6+2.6+3.5+5.3 2.1+3.5+3.5+5.3+6.2 2.6+2.6+3.5+6.2+6.2
2.1+2.1+2.1+2.6+6.2 2.1+2.1+2.6+5.3+6.2 2.1+2.6+2.6+3.5+6.2 2.6+2.6+2.6+2.6+2.6 2.6+2.6+5.3+5.3+5.3
2.1+2.1+2.1+2.6+7.0 2.1+2.1+2.6+5.3+7.0 2.1+2.6+2.6+3.5+7.0 2.6+2.6+2.6+2.6+3.5 2.6+3.5+3.5+3.5+3.5
2.1+2.1+2.1+3.5+3.5 2.1+2.1+2.6+6.2+7.0 2.1+2.6+2.6+5.3+5.3 2.6+2.6+2.6+2.6+5.3 2.6+3.5+3.5+3.5+5.3
2.1+2.1+2.1+3.5+5.3 2.1+2.1+2.6+7.0+7.0 2.1+2.6+2.6+5.3+6.2 2.6+2.6+2.6+2.6+6.2 2.6+3.5+3.5+3.5+6.2
2.1+2.1+2.1+3.5+6.2 2.1+2.1+3.5+3.5+3.5 2.1+2.6+2.6+5.3+7.0 2.6+2.6+2.6+2.6+7.0 2.6+3.5+3.5+3.5+7.0
2.1+2.1+2.1+3.5+7.0 2.1+2.1+3.5+3.5+5.3 2.1+2.6+2.6+6.2+6.2 2.6+2.6+2.6+3.5+3.5 2.6+3.5+3.5+5.3+5.3
2.1+2.1+2.1+5.3+5.3 2.1+2.1+3.5+3.5+6.2 2.1+2.6+2.6+6.2+7.0 2.6+2.6+2.6+3.5+5.3 2.6+3.5+3.5+5.3+6.2
2.1+2.1+2.1+5.3+6.2 2.1+2.1+3.5+3.5+7.0 2.1+2.6+3.5+3.5+3.5 2.6+2.6+2.6+3.5+6.2 3.5+3.5+3.5+3.5+3.5
2.1+2.1+2.1+5.3+7.0 2.1+2.1+3.5+5.3+5.3 2.1+2.6+3.5+3.5+5.3 2.6+2.6+2.6+3.5+7.0 3.5+3.5+3.5+3.5+5.32.1+2.1+2.1+6.2+6.2 2.1+2.1+3.5+3.5+6.2 2.1+2.6+3.5+3.5+6.2 2.6+2.6+2.6+5.3+5.3 3.5+3.5+3.5+3.5+6.2
2.1+2.1+2.1+6.2+7.0 2.1+2.1+3.5+5.3+7.0 2.1+2.6+3.5+3.5+7.0 2.6+2.6+2.6+5.3+6.2 3.5+3.5+3.5+3.5+7.0
2.1+2.1+2.1+7.0+7.0 2.1+2.1+3.5+6.2+6.2 2.1+2.6+3.5+5.3+5.3 2.6+2.6+2.6+5.3+7.0 3.5+3.5+3.5+5.3+5.3
2.1+2.1+2.6+2.6+2.6 2.1+2.1+3.5+6.2+7.0 2.1+2.6+3.5+5.3+6.2 2.6+2.6+2.6+6.2+6.2
S i x u n i t s
2.1+2.1+2.1+2.1+2.1+2.1 2.1+2.1+2.1+2.6+3.5+3.5 2.1+2.1+2.6+2.6+3.5+6.2 2.1+2.6+2.6+3.5+3.5+6.22.1+2.1+2.1+2.1+2.1+2.6 2.1+2.1+2.1+2.6+3.5+5.3 2.1+2.1+2.6+2.6+3.5+7.0 2.1+2.6+3.5+3.5+3.5+3.5
2.1+2.1+2.1+2.1+2.1+3.5 2.1+2.1+2.1+2.6+3.5+6.2 2.1+2.1+2.6+2.6+5.3+5.3 2.1+2.6+3.5+3.5+3.5+5.3
2.1+2.1+2.1+2.1+2.1+5.3 2.1+2.1+2.1+2.6+3.5+7.0 2.1+2.1+2.6+2.6+5.3+6.2 2.1+3.5+3.5+3.5+3.5+3.5
2.1+2.1+2.1*2.1+2.1+6.2 2.1+2.1+2.1+2.6+5.3+5.3 2.1+2.1+2.6+3.5+3.5+3.5 2.6+2.6+2.6+2.6+2.6+2.6
2.1+2.1+2.1+2.1+2.1+7.0 2.1+2.1+2.1+2.6+5.3+6.2 2.1+2.1+2.6+3.5+3.5+5.3 2.6+2.6+2.6+2.6+2.6+3.5
2.1+2.1+2.1+2.1+2.6+2.6 2.1+2.1+2.1+2.6+5.3+7.0 2.1+2.1+2.6+3.5+3.5+6.2 2.6+2.6+2.6+2.6+2.6+5.3
2.1+2.1+2.1+2.1+2.6+3.5 2.1+2.1+2.1+2.6+6.2+6.2 2.1+2.1+2.6+3.5+3.5+7.0 2.6+2.6+2.6+2.6+2.6+6.2
2.1+2.1+2.1+2.1+2.6+5.3 2.1+2.1+2.1+3.5+3.5+3.5 2.1+2.1+2.6+3.5+5.3+5.3 2.6+2.6+2.6+2.6+2.6+7.0
2.1+2.1+2.1+2.1+2.6+6.2 2.1+2.1+2.1+3.5+3.5+5.3 2.1+2.6+2.6+2.6+2.6+2.6 2.6+2.6+2.6+2.6+3.5+3.5
2.1+2.1+2.1+2.1+2.6+7.0 2.1+2.1+2.1+3.5+3.5+6.2 2.1+2.6+2.6+2.6+2.6+3.5 2.6+2.6+2.6+2.6+3.5+5.3
2.1+2.1+2.1+2.1+3.5+3.5 2.1+2.1+2.1+3.5+3.5+7.0 2.1+2.6+2.6+2.6+2.6+5.3 2.6+2.6+2.6+2.6+3.5+6.2
2.1+2.1+2.1+2.1+3.5+5.3 2.1+2.1+2.1+3.5+5.3+5.3 2.1+2.6+2.6+2.6+2.6+6.2 2.6+2.6+2.6+2.6+3.5+7.0
2.1+2.1+2.1+2.1+3.5+6.2 2.1+2.1+2.1+3.5+5.3+6.2 2.1+2.6+2.6+2.6+2.6+7.0 2.6+2.6+2.6+2.6+5.3+5.32.1+2.1+2.1+2.1+3.5+7.0 2.1+2.1+2.6+2.6+2.6+2.6 2.1+2.6+2.6+2.6+3.5+3.5 2.6+2.6+2.6+3.5+3.5+3.5
2.1+2.1+2.1+2.1+5.3+5.3 2.1+2.1+2.6+2.6+2.6+3.5 2.1+2.6+2.6+2.6+3.5+5.3 2.6+2.6+2.6+3.5+3.5+5.3
2.1+2.1+2.1+2.6+2.6+2.6 2.1+2.1+2.6+2.6+2.6+5.3 2.1+2.6+2.6+2.6+3.5+6.2 2.6+2.6+2.6+3.5+3.5+6.2
2.1+2.1+2.1+2.6+2.6+3.5 2.1+2.1+2.6+2.6+2.6+6.2 2.1+2.6+2.6+2.6+3.5+7.0 2.6+2.6+3.5+3.5+3.5+3.5
2.1+2.1+2.1+2.6+2.6+5.3 2.1+2.1+2.6+2.6+2.6+7.0 2.1+2.6+2.6+2.6+5.3+5.3 2.6+2.6+3.5+3.5+3.5+5.3
2.1+2.1+2.1+2.6+2.6+6.2 2.1+2.1+2.6+2.6+3.5+3.5 2.1+2.6+2.6+3.5+3.5+3.5 2.6+3.5+3.5+3.5+3.5+3.5
2.1+2.1+2.1+2.6+2.6+7.0 2.1+2.1+2.6+2.6+3.5+5.3 2.1+2.6+2.6+3.5+3.5+5.3 3.5+3.5+3.5+3.5+3.5+3.5
2.1+2.1+2.1+2.6+3.5+3.5
S e v e n u n i t s
2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .1 2 .1 +2 .1 +2 .1 +2 .1 +2 .6 +2 .6 +6 .2 2 .1 +2 .1 +2 .6 +2 .6 +2 .6 +2 .6 +3 .5
2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .6 2 .1 +2 .1 +2 .1 +2 .1 +2 .6 +2 .6 +7 .0 2 .1 +2 .1 +2 .6 +2 .6 +2 .6 +2 .6 +5 .3
2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +3 .5 2 .1 +2 .1 +2 .1 +2 .1 +2 .6 +3 .5 +3 .5 2 .1 +2 .1 +2 .6 +2 .6 +2 .6 +2 .6 +6 .2
2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +5 .3 2 .1 +2 .1 +2 .1 +2 .1 +2 .6 +3 .5 +5 .3 2 .1 +2 .1 +2 .6 +2 .6 +2 .6 +3 .5 +3 .52 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +6 .2 2 .1 +2 .1 +2 .1 +2 .1 +2 .6 +3 .5 +6 .2 2 .1 +2 .1 +2 .6 +2 .6 +2 .6 +3 .5 +5 .3
2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +7 .0 2 .1 +2 .1 +2 .1 +2 .1 +3 .5 +3 .5 +3 .5 2 .1 +2 .1 +2 .6 +2 .6 +3 .5 +3 .5 +3 .5
2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .6 +2 .6 2 .1 +2 .1 +2 .1 +2 .1 +3 .5 +3 .5 +5 .3 2 .1 +2 .1 +2 .6 +3 .5 +3 .5 +3 .5 +3 .5
2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .6 +3 .5 2 .1 +2 .1 +2 .1 +2 .6 +2 .6 +2 .6 +2 .6 2 .1 +2 .6 +2 .6 +2 .6 +2 .6 +2 .6 +2 .6
2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .6 +5 .3 2 .1 +2 .1 +2 .1 +2 .6 +2 .6 +2 .6 +3 .5 2 .1 +2 .6 +2 .6 +2 .6 +2 .6 +2 .6 +3 .5
2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .6 +6 .2 2 .1 +2 .1 +2 .1 +2 .6 +2 .6 +2 .6 +5 .3 2 .1 +2 .6 +2 .6 +2 .6 +2 .6 +2 .6 +5 .3
2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +2 .6 +7 .0 2 .1 +2 .1 +2 .1 +2 .6 +2 .6 +2 .6 +6 .2 2 .1 +2 .6 +2 .6 +2 .6 +2 .6 +3 .5 +3 .5
2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +3 .5 +3 .5 2 .1 +2 .1 +2 .1 +2 .6 +2 .6 +2 .6 +7 .0 2 .1 +2 .6 +2 .6 +2 .6 +3 .5 +3 .5 +3 .5
2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +3 .5 +5 .3 2 .1 +2 .1 +2 .1 +2 .6 +2 .6 +3 .5 +3 .5 2 .6 +2 .6 +2 .6 +2 .6 +2 .6 +2 .6 +2 .6
2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +3 .5 +6 .2 2 .1 +2 .1 +2 .1 +2 .6 +2 .6 +3 .5 +5 .3 2 .6 +2 .6 +2 .6 +2 .6 +2 .6 +2 .6 +3 .5
2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +3 .5 +7 .0 2 .1 +2 .1 +2 .1 +2 .6 +2 .6 +3 .5 +6 .2 2 .6 +2 .6 +2 .6 +2 .6 +2 .6 +2 .6 +5 .3
2 .1 +2 .1 +2 .1 +2 .1 +2 .1 +5 .3 +5 .3 2 .1 +2 .1 +2 .1 +2 .6 +3 .5 +3 .5 +3 .5 2 .6 +2 .6 +2 .6 +2 .6 +2 .6 +3 .5 +3 .5
E i g h t u n i t s
2.1+2.1+2.1+2.1+2.1+2.1+2.1+2.1 2.1+2.1+2.1+2.1+2.1+2.1+2.6+6.2 2.1+2.1+2.1+2.6+2.6+2.6+2.6+2.62.1+2.1+2.1+2.1+2.1+2.1+2.1+2.6 2.1+2.1+2.1+2.1+2.1+2.1+3.5+3.5 2.1+2.1+2.1+2.6+2.6+2.6+2.6+3.5
2.1+2.1+2.1+2.1+2.1+2.1+2.1+3.5 2.1+2.1+2.1+2.1+2.1+2.1+3.5+5.3 2.1+2.1+2.1+2.6+2.6+2.6+3.5+3.5
2.1+2.1+2.1+2.1+2.1+2.1+2.1+5.3 2.1+2.1+2.1+2.1+2.1+2.6+2.6+2.6 2.1+2.1+2.6+2.6+2.6+2.6+2.6+2.6
2.1+2.1+2.1+2.1+2.1+2.1+2.1+6.2 2.1+2.1+2.1+2.1+2.1+2.6+2.6+3.5 2.1+2.1+2.6+2.6+2.6+2.6+2.6+3.5
2.1+2.1+2.1+2.1+2.1+2.1+2.6+2.6 2.1+2.1+2.1+2.1+2.1+2.6+2.6+5.3 2.6+2.6+2.6+2.6+2.6+2.6+2.6+2.6
2.1+2.1+2.1+2.1+2.1+2.1+2.6+3.5 2.1+2.1+2.1+2.1+2.1+2.6+3.5+3.5
2.1+2.1+2.1+2.1+2.1+2.1+2.6+5.3 2.1+2.1+2.1+2.1+2.1+3.5+3.5+3.5
N i n e u n i t s
2.1+2.1+2.1+2.1+2.1+2.1+2.1+2.1+2.1 2.1+2.1+2.1+2.1+2.1+2.1+2.1+2.6+3.5
2.1+2.1+2.1+2.1+2.1+2.1+2.1+2.1+2.6 2.1+2.1+2.1+2.1+2.1+2.1+2.6+2.6+2.6
2.1+2.1+2.1+2.1+2.1+2.1+2.1+2.1+3.5 2.1+2.1+2.1+2.1+2.1+2.1+2.6+2.6+3.5
2.1+2.1+2.1+2.1+2.1+2.1+2.1+2.6+2.6 2.1+2.1+2.1+2.1+2.1+2.6+2.6+2.6+2.6
ACP-56COFM164GEEIThe most common indoor units combinations.
-
8/9/2019 VIVAX cool 2014.pdf
36/36
We reserve the right of eventual printing errors.34
M SAN Grupa d.d.
Exclusive distributor for Republic of CroatiaBuzinski prilaz 10, 10010 Buzin, Zagreb, CroatiaT +385 1 3654 900 | F +385 1 3654 [email protected] V
I V A X P
a r t n e r
vivax.com