VSL MULTISTRAND SYSTEMS:
Strand and Tendon PropertiesStrand PropertiesStrand TypeNominal diameter Nominal area Nominal weight/mass Tensile strength Min. breaking load Youngs modulus Relaxation inch inch2 lbs/ft ksi kips ksi %
0.5 (13 mm)
0.6 (15 mm)
0.5 0.6 0.153 0.217 0.53 0.74 270 270 41.3 58.6 approx. 28,500 max 2.5
www.vsl.net 888-489-2687
Tendon Properties
Strands Type 0.5 (270 ksi)Number of Strands Per Tendon 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 Area of tendon inch2 0.15 0.31 0.46 0.61 0.77 0.92 1.07 1.22 1.38 1.53 1.68 1.84 1.99 2.14 2.30 2.45 2.60 2.75 2.91 3.06 3.21 3.37 3.52 3.67 3.83 3.98 4.13 4.28 4.44 4.59 4.74 4.90 5.05 5.20 5.36 5.51 5.66 5.81 5.97 6.12 6.27 6.43 6.58 6.73 6.89 7.04 7.19 7.35 7.50 7.65 7.80 7.96 8.11 8.26 8.42 Min breaking load kips 41.3 82.6 123.9 165.2 206.5 247.8 289.1 330.4 371.7 413.0 454.3 495.6 536.9 578.2 619.5 660.8 702.1 743.4 784.7 826.0 867.3 908.6 949.9 991.2 1032.5 1073.8 1115.1 1156.4 1197.7 1239.0 1280.3 1321.6 1362.9 1404.2 1445.5 1486.8 1528.1 1569.4 1610.7 1652.0 1693.3 1734.6 1775.9 1817.2 1858.5 1899.8 1941.1 1982.4 2023.7 2065.0 2106.3 2147.6 2188.9 2230.2 2271.5
Strands Type 0.6 (270 ksi)Number of Strands Per Tendon 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 Area of tendon inch2 0.22 0.43 0.65 0.87 1.09 1.30 1.52 1.74 1.95 2.17 2.39 2.60 2.82 3.03 3.26 3.47 3.69 3.91 4.12 4.34 4.56 4.78 4.99 5.21 5.43 5.64 5.86 6.08 6.29 6.51 6.73 6.94 7.16 7.38 7.60 7.81 8.03 8.25 8.46 8.68 8.90 9.11 9.33 9.55 9.77 9.98 10.20 10.42 10.63 10.85 11.07 11.28 11.50 11.72 11.94 Min breaking load kips 58.6 117.2 175.8 234.4 293.0 351.6 410.2 468.8 527.4 586.0 644.6 703.2 761.8 820.4 879.0 937.6 996.2 1054.8 1113.4 1172.0 1230.6 1289.2 1347.8 1406.4 1465.0 1523.6 1582.2 1640.8 1699.4 1758.0 1816.6 1875.2 1933.8 1992.4 2051.0 2109.6 2168.2 2226.8 2285.4 2344.0 2402.6 2461.2 2519.8 2578.4 2637.0 2695.6 2754.2 2812.8 2871.4 2930.0 2988.6 3047.2 3105.8 3164.4 3223.0
VSL US Technical Data and Dimensions Strand and Tendon Properties 0308 VStructural, LLC
VSL MULTISTRAND SYSTEMS:
Type ECI Stressing Anchorage
Dimensions (Inches) Tendon Unit 6-7 6-7 6-12 6-12 6-19 6-19 fci (psi) 3500 5500 3500 5500 3500 5500 A 8.54 8.54 9.88 9.88 B C D E F PT+ Duct 2.87 2.87 3.58 3.58 4.57 4.57 F Steel Duct 2.88 2.88 3.24 3.24 4.10 4.10 F SCH 40 Pipe 3.00 3.00 3.50 3.50 4.50 4.50 G H K PT+ Duct K Steel Duct K SCH 40 Pipe L #4 #4 #5 #4 #5 #5 n 6.50 6.50 7.00 7.00 11.50 10.50 P 3.00 3.00 3.00 3.00 2.00 2.00 Q 7.40 7.40 8.66 8.66 10.24 10.24 R 4.17 4.17 4.90 4.90 5.63 5.63 X 13.00 13.00 15.00 15.00 19.00 17.00
6.69 2.37 5.33 3.31 6.69 2.37 5.33 3.31 8.66 3.00 6.85 4.62 8.66 3.00 6.85 4.62
11.00 12.00 11.00 12.00 13.00 14.00 13.00 13.50 17.00 19.00 15.00 17.00
No Trumpet on 6-7 No Trumpet on 6-12 15.19 15.19 12.09 12.09 9.29 9.29
11.42 6.91 3.75 8.13 5.90 11.42 6.91 3.75 8.13 5.90
Notes: Anchorage spacings are in accordance with test requirement of AASHTO (The Special Anchorage Device Acceptance Test Procedure, AASHTO 2000). For proper design and detailing of anchorage zones and related reinforcement, refer to the VSL Publication Detailing for Post-Tensioning. Dimensions are valid for: fci (psi) is the nominal minimum concrete cylinder strength at the time of stressing. Maximum prestressing force may be applied when concrete reaches a cylinder strength of 3,500 psi (24 MPa) and 5,500 psi (38 MPa) respectively. Temporary overstressing to 80% of Guaranteed Ultimate Tensile Strength. Yield strength of spiral reinforcement: Grade 60 (400 MPa). Tie one and one-half turns of spiral at both ends. Additional orthogonal reinforcement may be required in the local anchorage zone as determined by design. Spirals may be replaced by suitable orthogonal reinforcement. Information for other concrete strengths and conditions is available from your local VSL Representative. Spiral reinforcement shall be centered on the anchorage assembly and be placed directly behind the bearing plate as indicated above.VSL US Technical Data and Dimensions ECI Multistrand 1207 VStructural, LLC
www.vsl.net 888-489-2687
Multistrand Post-TensioningStressing Anchorage VSL Type ES
VSL
K (super) ~1.25" C K (std) H G A
D
E
Spiral reinforcement L x n turns (pitch = H/n)
J
X = Anchorage spacing XR = Clearence to edge XR = 1 X + required cover of 2 spiral reinforcing
B
Drawings not to scale
Tendon UnitA 5-12 5-19 5-31 5-43 5-55 6-7 6-12 6-19 6-22 6-31 6-37 8.74 10.16 12.60 15.35 16.54 8.74 10.16 11.81 12.60 15.35 16.54 Strand Type 0.5'' B 2.36 3.15 3.94 4.72 5.12 2.36 3.15 3.54 3.94 4.72 5.12 C 2.38 3.00 4.00 5.20 5.50 2.38 3.25 3.75 4.00 5.20 5.50 D 6.00 7.00 9.00 11.10 12.00 6.00 7.00 8.25 9.00 11.10 12.00 E 4.06 5.13 6.59 8.57 9.01 4.06 5.13 5.88 6.59 8.57 9.01
Dimensions InchesG 10.50 13.75 18.00 21.75 24.75 10.50 13.75 17.00 18.00 21.75 24.75 H 10.00 14.00 18.00 20.00 22.50 10.00 14.00 18.00 18.00 20.00 22.50 J 4.33 4.82 5.91 7.24 7.80 4.33 4.82 5.61 5.91 7.24 7.80 K(std)
K(super)
L #4 #5 #5 #5 #6 #4 #5 #5 #5 #5 #6
n 5 7 9 10 10 5 7 9 9 10 10
X 12.50 15.75 20.50 23.75 26.75 12.50 15.75 19.00 20.50 23.75 26.75
13.00 16.93 19.69 28.75 27.55 13.00 16.93 19.69 19.69 28.75 27.55
16.38 20.22 23.86 NA NA 16.38 20.22 22.13 23.86 NA NA
Strand Type 0.6''
Other sizes available on request Anchorage spacings are in accordance with test requirements of FIP (Recommendations for Acceptance of Post-Tensioning Systems: March 1992). For proper design and detailing of anchorage zones and related reinforcement, refer to the VSL Publication Detailing for Post-Tensioning. Dimensions are valid for: Nominal concrete cylinder strength at 28 days: 4,000 psi (28 MPa). Maximum prestressing force may be applied when concrete reaches a cylinder strength of 3,500 psi (24 MPa). Temporary overstressing to 80% of Guaranteed Ultimate Tensile Strength. Yield strength of spiral reinforcement: Grade 60 (400 MPa).
Subject to modification Additional orthogonal reinforcement may be required in the local anchorage zone as determined by design. Spirals may be replaced by suitable orthogonal reinforcement. Information for other concrete strengths and conditions are available from your local VSL Representative. Spiral reinforcement shall be centered on the anchorage assembly and be placed directly behind the bearing plate.
VSL/DSUS_Multi_SA_ES
1M 5/02 VStructural, LLC
www.vsl.net
2
Multistrand Post-TensioningStressing Anchorage VSL Type EC
VSL
~1.25" C B
H
G A
D
E
F
A
Spiral reinforcement L x n turns (pitch = H/n)
X = Anchorage spacing XR = Clearence to edge XR = 1 X + required cover of 2 spiral reinforcing
Tendon UnitA Strand Type 0.5'' 5-7 5-12 5-19 5-27 5-31 6.50 8.88 11.00 12.38 14.00 B 5.25 7.06 10.25 13.63 13.63 C 2.38 2.38 3.00 4.00 4.00 D 4.50 6.00 7.00 9.00 9.00
Dimensions InchesE 2.91 4.31 5.56 7.00 7.00 F 2.50 3.13 3.75 4.75 4.75 G 9.00 11.75 15.00 18.00 19.00 H 12.00 16.00 18.00 18.00 20.25 L #4 #4 #5 #6 #6 n 6 8 8 8 9 X 9.50 12.50 15.75 18.75 20.00
Other sizes available on request Anchorage spacings are in accordance with test requirements of FIP (Recommendations for Acceptance of Post-Tensioning Systems: March 1992). For proper design and detailing of anchorage zones and related reinforcement, refer to the VSL Publication Detailing for Post-Tensioning. Dimensions are valid for: Nominal concrete cylinder strength at 28 days: 4,000 psi (28 MPa). Maximum prestressing force may be applied when concrete reaches a cylinder strength of 3,500 psi (24 MPa). Temporary overstressing to 80% of Guaranteed Ultimate Tensile Strength.
Subject to modification Yield strength of spiral reinforcement: Grade 60 (400 MPa). Spirals may be replaced by suitable orthogonal reinforcement. Information for other concrete strengths and conditions are available from your local VSL Representative. Spiral reinforcement shall be centered on the anchorage assembly and be placed directly behind the bearing plate. Additional orthogonal reinforcement may be required in the local anchorage zone as determined by design.
VSL/DSUS_Multi_SA_EC
1M 5/02 VStructural, LLC
www.vsl.net
3
VSL MULTISTRAND SYSTEMS:
Type E Stressing AnchorageStressing Anchorage VSL Type E~1.25" C F H G A
D
E
B
Spiral reinforcement L x n turns (pitch = H/n)
X = Anchorage spacing XR = Clearance to edge XR =1 2X
+ required cover of spiral reinforcing
Bearing Plate (Steel)
Grout Hose Duct
Dimensions (Inches) Tendon Unit 5-1 5-3 5-4 5-7 5-12 5-19 5-22 5-31 5-37 5-43 5-55 6-1 6-2 6-3 6-4 6-7 6-12 6-19 6-22 6-31 6-37 6-43 6-55 A 2.76 4.53 5.12 6.89 9.06 11.42 12.40 14.57 15.94 17.32 19.69 2.95 4.33 5.31 6.30 8.07 10.63 13.39 14.57 17.13 18.90 20.47 22.83 B 0.59 0.79 0.79 0.98 1.38 1.57 1.77 2.17 2.36 2.36 2.76 0.59 0.59 0.79 0.98 1.38 1.57 1.97 2.17 2.56 2.76 2.95 3.54 C D E F 2.76 7.48 7.48 7.48 14.57 18.50 18.90 21.65 22.44 26.77 26.77 2.76 7.48 7.48 7.48 11.42 18.11 23.23 27.17 27.17 32.68 37.40 37.40 G 3.15 5.12 6.30 8.07 11.22 14.37 15.55 18.50 20.08 21.65 24.41 3.15 5.12 6.30 7.48 10.24 13.58 17.32 18.50 22.05 24.02 25.59 29.13 H 3.54 5.91 5.91 7.87 9.84 11.81 14.17 15.75 16.54 18.90 21.26 3.54 5.91 5.91 7.87 9.84 11.81 13.78 15.75 18.90 21.26 25.20 24.80 J 0.98 1.57 1.77 2.17 2.56 3.15 3.35 3.94 4.72 5.12 5.51 1.18 1.77 1.77 1.97 2.36 3.15 3.74 4.33 5.12 5.51 5.91 6.69 J 2) 1.18 1.17 1.97 2.36 2.83 3.43 3.62 4.21 5.00 5.39 5.91 1.38 1.97 1.97 2.17 2.64 3.43 4.02 4.61 5.39 5.91 6.30 7.09 L #3 #4 #4 #4 #4 #5 #6 #5 #7 #7 #7 #3 #4 #4 #4 #4 #5 #5 #6 #7 #7 #8 #8 n 2 3 3 4 5 6 6 8 7 8 9 2 3 3 4 5 6 9 8 8 9 8 9 X 3.54 6.10 7.09 9.25 12.01 15.16 16.34 19.29 21.06 22.83 25.79 4.13 5.91 7.28 8.27 11.02 14.37 18.11 19.49 23.23 25.20 27.17 30.71
0.5 Strand
Trumpet Anchor Head
1.77 1.65 0.59 1.97 3.54 1.97 1.97 3.74 2.17 2.17 4.33 2.91 2.36 5.91 4.09 2.95 7.09 5.31 3.35 7.48 5.91 3.74 9.06 6.77 4.13 9.45 7.40 4.33 10.24 8.50 5.12 11.42 9.06 1.97 1.97 1.97 2.17 2.36 2.95 3.74 3.94 4.72 5.31 5.71 6.30 2.09 3.54 3.74 4.33 5.31 6.69 7.87 8.66 10.24 11.02 11.81 13.39 0.71 1.97 2.20 2.56 3.31 4.65 5.91 6.77 7.56 8.46 9.69 10.04
www.vsl.net 888-489-2687
0.6 Strand
Notes: Other sizes available on request. Anchorage spacings are in accordance with test requirements of FIP (Recommendations for Acceptance of Post-Tensioning Systems: March 1992). For proper design and detailing of anchorage zones and related reinforcement, refer to the VSL Publication Detailing for Post-Tensioning. Dimensions are valid for: Nominal minimum concrete cylinder strength at 28 days: 4000 psi (28 MPa). Maximum prestressing force may be applied when concrete reaches a cylinder strength of 3,500 psi (24 MPa). Temporary overstressing to 80% of Guaranteed Ultimate Tensile Strength. Yield strength of spiral reinforcement: Grade 60 (400 MPa). Information for other concrete strength and conditions are available from your local VSL Representative. Large bearing plates are available where bearing stress is arbitrarily limited to 3,000 psi (21 MPa) with the tendon locked off at 70% Guaranteed Ultimate Tensile Strength. Spiral reinforcement shall be centered on the anchorage assembly and be placed directly behind the bearing plate. Additional orthogonal reinforcement may be required in the local anchorage zone as determined by design.VSL US Technical Data and Dimensions E Multistrand 0308 VStructural, LLC
A
VSL MULTISTRAND SYSTEMS:
Type K Coupler
Dimensions (Inches) Tendon Unit 5-3 5-7 5-12 5-19 5-22 5-31 5-37 5-42 5-55 6-2 6-3 6-4 6-7 6-12 6-19 6-22 6-31 6-37 A 16.93 21.65 25.59 29.13 32.68 44.88 51.97 50.79 53.94 14.96 19.29 20.47 24.80 28.74 33.86 36.61 42.91 54.72 B 5.51 5.51 5.51 5.51 5.51 5.51 7.09 7.09 7.87 5.91 6.30 6.30 6.30 6.30 6.30 6.30 7.09 7.87 C 1.57 2.36 2.36 3.15 3.54 3.54 4.72 5.12 5.91 1.18 2.36 2.36 2.76 3.15 3.54 3.54 5.12 5.12 D 5.12 6.69 7.87 9.45 10.24 13.78 15.35 15.55 16.54 5.51 5.91 6.30 7.48 9.45 11.02 12.20 14.17 16.93
0.5 Strand
0.6 Strand
Grout Hose Coupling Head K Trumpet
Bearing Plate Type EC, ES or E Duct
Notes: Tension ring required as shown. Refer to applicable systems data sheet for bearing plate data and dimensions. Use of couplers requires special procedures and detailing. Contact your local VSL Representative.
Tension Ring
Compression Fittings
www.vsl.net 888-489-2687VSL US Technical Data and Dimensions K Multistrand 0308 VStructural, LLC
VSL MULTISTRAND SYSTEMS:
Type T Dead-End Anchorage
C
G B
Spiral reinforcement L x n turns (pitch = H/n)
Tension Ring
X = Anchorage spacing XR = Clearance to edge XR = X + required cover of spiral reinforcing
Dimensions (Inches) Tendon Unit 0.5 Strand 5-12 5-19 5-31 6-7 6-12 6-19 A 6.60 11.00 16.00 6.75 6.75 9.00 B 8.80 11.00 11.00 6.75 6.00 11.25 C 36.00 36.00 36.00 36.00 36.00 36.00 G 11.75 15.00 19.00 X 12.50 15.75 20.00 12.50 15.75 20.00
0.6 Strand
Notes:Grout Hose Tension Ring
Anchorage spacings are in accordance with test requirement of AASHTO (The Special Anchorage Device Acceptance Test Procedure, AASHTO 2000). For proper design and detailing of anchorage zones and related reinforcement, refer to the VSL Publication Detailing for Post-Tensioning.
Duct
Dimensions are valid for:
Seal Type T Anchorage
Nominal minimum concrete cylinder strength at 28 days: 4000 psi (28 MPa). Maximum prestressing force may be applied when concrete reaches a cylinder strength of 3,500 psi (24 MPa). Temporary overstressing to 80% of Guaranteed Ultimate Tensile Strength. Information for other concrete strength and conditions are available from your local VSL Representative.
www.vsl.net 888-489-2687VSL US Technical Data and Dimensions T Multistrand 0308 VStructural, LLC
A
VSL MULTISTRAND SYSTEMS:
Type Z Intermediate AnchorageStressing Jack Stressing Jack Curved stressing chair VSL Type Z Anchorage Curved stressing chair
VSL Type Z Anchorage
VSL Type Z Anchorage
D
C
Tendon #2 Curved stressing chair Tendon #2 Tension Ring Tension Ring
F+L F+L G+L G+L B
B
Tendon #1 Tendon #1
C
HTendon #2 Tendon #2
F+L G+L
L E Elongation of tendon #2 = = C/2 + required cover B Tendon #1 E = C/2 + required cover
C
L = Elongation of tendon #2
H
H
Stressing Jack
D
E
E
Tendon #2
A
Tendon #1
Dimensions (Inches)#2
Tendon Unit 5-2 1) 5-4 1) 5-6 5-8 5-12 5-22 6-2 1) 6-4 1) 6-6 6-12 6-22
A 5.12 6.30 7.87 8.62 11.02 13.78 5.51 6.69 8.27 11.81 15.75
B 2.36 2.76 3.54 4.12 5.51 6.69 2.76 3.15 3.94 6.30 7.48
C 3.15 3.54 5.12 4.50 5.51 7.87 3.54 3.94 5.51 6.30 9.84
D 2.36 2.56 3.35 3.00 3.54 4.72 2.56 2.76 3.54 3.94 5.71
F2 15.75 19.69 23.62 29.50 39.37 57.09 17.72 35.43 39.37 53.15 59.06
G2 22.05 28.35 35.04 46.38 56.69 81.50 24.41 44.49 51.97 75.20 90.16
H 6.69 7.87 9.45 10.25 12.60 15.35 7.09 8.27 9.84 13.39 17.32
0.5 Strand
0.6 Strand
Notes:Grout Hose Tension Ring with Anchors Duct
Tension ring required on #2 side of the anchorage. Blockout dimensions dependent upon the shape of the concrete surface and the tendon elongation. The values stated apply for surfaces which are not curved.
Anchor Head Type Z
Retainer Plate
www.vsl.net 888-489-2687VSL US Technical Data and Dimensions Z Multistrand 0308 VStructural, LLC
Multistrand Post-TensioningDead-End Anchorage VSL Type L
VSL
R
Hairpin bar reinforcement
Tendon UnitStrand Type 0.5'' 5-7 5-12 5-19 5-31 2.62 3.50 3.94 5.75
Dimensions InchesA Internal A External 2.88 3.75 4.19 6.00 R min. 24.00 36.00 36.00 36.00Subject to modification Yield strength of spiral reinforcement: Grade 60 (400 MPa). Custom size VSL Loops are available. Information for other concrete strengths and conditions are available from your local VSL Representative. Simultaneous stressing of both tendon ends is necessary.
Other sizes available on request For proper design and detailing of anchorage zones and related reinforcement, refer to the VSL Publication Detailing for Post-Tensioning. Dimensions are valid for: Nominal concrete cylinder strength at 28 days: 4,000 psi (28 MPa). Maximum prestressing force may be applied when concrete reaches a cylinder strength of 3,500 psi (24 MPa). Temporary overstressing to 80% of Guaranteed Ultimate Tensile Strength.
A
VSL/DSUS_Multi_DEA_L
1M 5/02 VStructural, LLC
www.vsl.net
8
VSL MULTISTRAND SYSTEMS:
Type AF Dead-End AnchorageF
G2nd injection
Overflow of 1st. injection
H
K
1st. injection
M
C
D
L
E
X = Anchorage spacing XR = Clearance to edge
ASpiral reinforcement L x n turns (pitch = H/n)
Dimensions (Inches) Tendon Unit 0.6 Strand 6-12 6-19 6-31 A 10.43 12.40 14.76 C 2.36 2.36 2.36 D 18.11 18.11 25.98 E 3.54 3.54 3.54 F Int. 3.74 4.72 5.91 F (2) Ext. 4.02 5.00 6.18 G 14.96 18.90 24.41 H 17.72 21.26 25.98 K 27.56 27.56 35.43 L #5 #6 #7 n 9.00 9.00 12.00 M 2.36 2.36 3.15 X 16.00 20.00 26.00
Duct
Notes: Anchorage spacings are in accordance with test requirement of AASHTO (The Special Anchorage Device Acceptance Test Procedure, AASHTO 2000). For proper design and detailing of anchorage zones and related reinforcement, refer to the VSL Publication Detailing for Post-Tensioning. Dimensions are valid for: Nominal minimum concrete cylinder strength at 28 days: 4000 psi (28 MPa). Maximum prestressing force may be applied when concrete reaches a cylinder strength of 3,500 psi (24 MPa). Temporary overstressing to 80% of Guaranteed Ultimate Tensile Strength. Yield strength of spiral reinforcement: Grade 60 (400 MPa). Spirals may be replaced by suitable orthogonal reinforcement. Information for other concrete strength and conditions are available from your local VSL Representative.
Cover Plate
Trumpet
Strand
www.vsl.net 888-489-2687VSL US Technical Data and Dimensions AF Multistrand 0308 VStructural, LLC
VSL MULTISTRAND SYSTEMS:
PT-Plus Duct
Ducts PT-Plus System
Polypropylene (PP) Plastic Duct
Ducts PTPlus System
www.vsl.net 888-489-2687ED
G0.88
H
Grout/vent connection
C
B
A
Type 59mm 76mm 100mm 115mm 130mm 150mm
Unit 0.6 6-7 6-12 6-19 / 22 6-27 6-31 / 37 6-43 / 55 A 2.28 2.99 3.94 4.53 5.12 5.91 B 2.48 3.19 4.17 4.76 5.35 6.18 C 2.87 3.58 4.57 5.16 5.75 6.57
Dimensions (Inches) D 0.10 0.10 0.12 0.12 0.12 0.14 E 1.65 2.00 2.00 2.36 2.00 2.36 F 3.23 3.94 4.84 5.43 6.14 6.89 G 4.25 4.57 4.96 5.00 5.47 4.96 H 4.17 4.88 5.79 5.83 6.97 7.28
Eccentricity of the Center of Gravity of Strands
Duct 59mm 76mm 100mm 100mm 115mm 130mm 130mm 150mm 150mm
System 6-7 6-12 6-19 6-22 6-27 6-31 6-37 6-43 6-55
Eccentricity 0.36 0.48 0.72 0.57 0.75 0.99 0.77 1.11 0.72
Offset 1 0.88 1.11 1.37 1.51 1.63 1.73 1.95 1.99 2.37
Offset 2 1.60 2.08 2.81 2.66 3.13 3.71 3.48 4.20 3.82
VSL US Technical Data and Dimensions Multistrand Duct 0708 VStructural, LLC
F
1.5
Multistrand Post-TensioningStrand proje ction B
VSL
Block Out Dimensions and Clearance Requirement
Concrete cover according to applicable standard
B
A
A
D
E
C
E
Jack TypeZPE-23FJ ZPE-30 ZPE-3 ZPE-60 ZPE-7A ZPE-12St2 ZPE-200 ZPE-19 ZPE-460/31 ZPE-500 ZPE-750 ZPE-1000 ZPE-1250
A min.1.18 1.18 1.18 1.18 1.97 1.97 1.97 2.36 3.15 3.15 3.15 3.54
B 12.00 24.00 22.00 26.00 32.00 28.00 44.00 34.00 28.00 46.00 54.00 52.00 54.00
C 47.25 43.50 39.50 43.50 47.25 51.25 82.75 59.25 59.25 78.75 90.75 86.75 88.75
D 4.57 5.51 7.87 7.09 11.81 12.20 12.99 15.35 19.09 23.03 22.44 31.10 25.98
E 3.50 4.00 6.00 5.50 8.00 8.00 8.25 10.00 12.00 13.00 14.50 17.75 14.75
Dimensions in inches.
VSL/DSUS_Multi_Block/Clear+
1M 5/02 VStructural, LLC
www.vsl.net 11
Multistrand Post-TensioningStressing Jack Data
VSL
Type I (ZPE-23FJ)
Type II (ZPE-19)
Type III (ZPE-500)
DesignationType Length (in) Diameter (in) Stroke (in) Piston area (in^2) Capacity (kips) Pressure (psi) Weight (lb) Used for 13 mm (0.5'') tendon types Used for 15 mm (0.6'') tendon types
ZPE-23FJ
ZPE-30
ZPE-3
ZPE-60
ZPE-7A
ZPE-12St2 ZPE-200
ZPE-19
ZPE-460/31 ZPE-500
ZPE-750
ZPE-1000
I 31.10 4.57 7.87 7.30 52 7078 51 5-1 6-1
III 28.35 5.51 9.84 9.04 72 7963 62 5-1 6-1
III 18.70 7.87 6.30 16.06 112 7005 104 5-2, 5-3 6-2
III
III
II
III
II 29.53 15.35 3.94 77.55 652 8412 648 5-18 5-19 6-12
II 22.83 19.09 3.94 124.62 1048 8412 959 5-22 5-31 6-18, 6-19
III 39.37 21.65 7.87 138.66 1124 8108 2346 5-22 5-31 6-18 to 6-22
II 46.65 20.47 5.91 193.29 1686 8717 2425 5-31 5-37 6-31
III 47.24 31.10 7.87 280.47 2248 8021 5049 5-37 to 5-55 6-31 to 6-43
24.21 27.17 21.65 37.80 7.09 11.02 12.20 12.40 9.84 6.30 3.94 11.81 19.59 31.56 47.96 50.48 142 239 416 450 7252 7585 8673 8905 163 254 333 672 5-2 5-6, 5-7 5-12 5-12 to 5-4 6-2, 6-3 6-4 6-6, 6-7 6-6, 6-7
Other sizes available on request
VSL/DSUS_Multi_Jacks
1M 5/02 VStructural, LLC
www.vsl.net 12
Bonded Slab Post-TensioningStressing Anchorage VSL Type SOGrout tube Wedges Strands Flat duct
VSL
Trumpet Anchorage body
Recess former
EGrout tube
X = Anchorage spacing XR = Clearence to edge XR = 1 X + required cover of 2 spiral reinforcing
L min. F H J NGeneral slab reinforcement Detail of reinforcement
D
B
K min.
For proper design and detailing of anchorage zones and related reinforcement, refer to the VSL Publication "Detailing for Post-Tensioning" The arrangement shown . here is common for slabs in buildings.
M 90 250
C
A
Type6-41
A13.00
B6.62
C11.25
L
D4.90
E3.00
F5.00
H2K-1.2
J3.00
Kmin4.75
L min31.5 x K
M#4
N#5
X13.88
Other sizes available on request For proper design and detailing of anchorage zones and related reinforcement, refer to the VSL Publication Detailing for Post-Tensioning. Dimensions in inches. Dimensions are valid for: Nominal concrete cylinder strength at 28 days: 4,000 psi (28 MPa). Maximum prestressing force may be applied when concrete reaches a cylinder strength of 80% of its nominal strength or 3,500 psi (24 MPa) whichever is less.
Subject to modification Temporary overstressing to 80% of Guaranteed Ultimate Tensile Strength. Information for other concrete strengths and conditions are available from your local VSL Representative. 1) Anchorage may be used with 0.5 (12.7 mm) or 6 (15.2 mm) strand. 2) Use actual K when calculating H. 3) L shall be the maximum permitted by the slab thickness and cover, whereas Lmm = 1.5 x K.
VSL/DSUS_Bonded_SA_SO
1M 5/02 VStructural, LLC
www.vsl.net 13
Bonded Slab Post-TensioningDimensions of Ductss
VSL
b B
Tendon unitPlastic duct PT-PLUSTM Plastic duct PT-PLUSTM Steel duct Dimensions in inches. 5-2, 6-2 5-4, 6-4 5-4, 6-4
h0.75 0.83 0.71
H1.18 1.38 0.83
H
h
b1.65 2.83 2.83
B2.09 3.39 2.95
s0.08 0.08 0.01
Coupler VSL Type SK
TypeSK 5-4 Dimensions in inches.
G16.06
H5.91
J5.51
K6.69
Dimensions are valid for nominal concrete strength: 20 MPa (cube), 16 MPa (cylinder), at the time of stressing, for a maximum stressing force of 80% of the tendon breaking load.
VSL/DSUS_Bonded_Duct/CoupSK
1M 5/02 VStructural, LLC
www.vsl.net 14
Bonded Slab Post-TensioningVSLAB + Stressing Anchorage
VSL
TypeVSLAB Dimensions in inches.
A5.12
B4.13
C3.27
D3.07
E4.02
F5.63
G4.72
H6.42
Dimensions are valid for nominal concrete strength: 3,000 psi (20 MPa) cylindrical strength, at the time of stressing, for a maximum stressing force of 80% of the tendon breaking load.
VSLAB + Intermediate Anchorage
1.65"3.35" Coupler
3.07" 13.19" 0.9" 2.75" Coupler Depth A
VSL/DSUS_Bonded_VSLAB
1M 5/02 VStructural, LLC
www.vsl.net 15
Bonded Slab Post-TensioningStressing Anchorage VSL Type SA
VSL
TypeSA5-4 SA5-5 SA6-4Other sizes available on request
A10.42 10.42 10.42
B3.70 3.70 3.70
C8.50 8.50 8.50
D9.75 9.75 9.75
E1.75 1.75 2.24
F1.96 1.96 2.64
G6.75 8.25 7.51
R4.33 4.33 4.33
Subject to modification Maximum prestressing force may be applied when concrete reaches a cylinder strength of 80% of its nominal strength or 3,000 psi (20 MPa) whichever is less. Temporary overstressing to 80% of Guaranteed Ultimate Tensile Strength. Information for other concrete strengths and conditions are available from your local VSL Representative.
For proper design and detailing of anchorage zones and related reinforcement, refer to the VSL Publication Detailing for Post-Tensioning. Dimensions in inches. Dimensions are valid for: Nominal concrete cylinder strength at 28 days: 4,000 psi (28 MPa).
VSL/DSUS_Bonded_SA_SA
1M 5/02 VStructural, LLC
www.vsl.net 16
VSL BONDED SLAB POST-TENSIONING SYSTEMS:
Type N Stressing Anchorage
Dimensions (Inches) Type N 5-4 N 5-5 N 6-4 Vertical A 9.75 12.25 14.00 B 5 5 6 C 36 36 36
Grout Hose
Notes: Other sizes available on request. For proper design and detailing of anchorage zones and related reinforcements, refer to the VSL Publication Detailing for Post-Tensioning. Tension ring required. Dimensions are valid for: Nominal concrete cylinder strength at 28 days: 4000 psi (28 MPa). Maximum prestressing force may be applied when concrete reaches a cylinder strength of 80% of its nominal strength or 3,000 psi (20 MPa) whichever is less. Temporary overstressing to 80% of Guaranteed Ultimate Tensile Strength. Information for other concrete strength and conditions are available from your local VSL Representative.Flat Duct
Tension Ring
www.vsl.net 888-489-2687VSL US Technical Data and Dimensions N Bonded Slab 0308 VStructural, LLC
VSL MONOSTRAND POST-TENSIONING SYSTEMS:
Type S5N / S6N Anchorages
Anchorages
Dimensions (Inches) Type S5N S6N A 5.00 4.63 B 2.25 3.50 C 1.50 1.88
Standard Pocket Formers
VSL US Technical Data and Dimensions S5N / S6N Monostrand 0308 VStructural, LLC
Monostrand Post-TensioningStressing Anchorage VSL Type S-6*
VSL
TypeS-6
A4.13
B2.95
C4.33
D4.53
E0.91
F1.57
G0.79
H6.25
* for 0.79 cover, to be adjusted for other values as needed. Dimensions in inches. Dimensions are valid for nominal concrete strength: 3,000 psi (20 MPa), at the time of stressing, for a maximum stressing force of 80% of the tendon breaking load.
Dead-End Anchorage VSL Type SF-6
TypeSF-6 Dimensions in inches.
A4.13
B2.95
C3.74
D4.53
E0.91
H6.25
Dimensions are valid for nominal concrete strength: 3,000 psi (20 MPa), at the time of stressing, for a maximum stressing force of 80% of the tendon breaking load.VSL/DSUS_Mono_SA_S6/DEA_SF6 1M 5/02 VStructural, LLC
www.vsl.net 18
Monostrand Post-TensioningCoupler VSL Type SK-6
VSL
TypeSK-6 Dimensions in inches.
A4.13
B2.95
C4.33
D2.56
E4.53
F4.53
G6.25
Dimensions are valid for nominal concrete strength: 3,000 psi (20 MPa), at the time of stressing, for a maximum stressing force of 80% of the tendon breaking load.
VSL/DSUS_Mono_Coup_SK6
1M 5/02 VStructural, LLC
www.vsl.net 19
Monostrand Post-TensioningAnchorage VSL Type S5CP+
VSL
End Cap
Intermediate Cap
Pocket Former
Split Pocket Former
TypeCP+
A5.00
B2.25
C2.50
D15
E1.50
F2.5
G4
H2.5
I2.5
J2.81
VSL/DSUS_Mono_Anchor_S5CP+
1M 5/02 VStructural, LLC
www.vsl.net 21