· web viewkaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide...

90
TASNİF DIŞI T.Ş. NU. : 73401242-BYD- TŞ-2016/18 T.C. DENİZ KUVVETLERİ KOMUTANLIĞI İSTANBUL TERSANESİ KOMUTANLIĞI PENDİK/İSTANBUL GALVANİZ BİNASININ TADİL EDİLEREK AMBAR/ATÖLYE HALİNE GETİRİLMESİ PROJE HİZMET ALIMI İŞİ TEKNİK ŞARTNAMESİ TEKNİK ŞARTNAME NO : 73401242-BYD-TŞ-2016/18 TASNİF DIŞI 0

Upload: others

Post on 25-Dec-2019

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

T.C.DENİZ KUVVETLERİ KOMUTANLIĞI

İSTANBUL TERSANESİ KOMUTANLIĞIPENDİK/İSTANBUL

GALVANİZ BİNASININTADİL EDİLEREK

AMBAR/ATÖLYE HALİNE GETİRİLMESİPROJE HİZMET ALIMI

İŞİTEKNİK ŞARTNAMESİ

TEKNİK ŞARTNAME NO : 73401242-BYD-TŞ-2016/18

TASNİF DIŞI 0

Page 2:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

TEKNİK ŞARTNAMEA- İŞİN ADI :

Galvaniz Binasının Tadil Edilerek Ambar/Atölye Haline Getirilmesi Proje Hizmet Alımı.

B- İŞİN KAPSAMI :

İstanbul Tersanesi Komutanlığı İşletme Müdürlüğü bağlısı 67A / 67B / 67C Elektronik Atölyelerinin, 51 m x 22 m ebadında eski Galvaniz Atölyesi binası içerisine konuşlandırılması için, ilgili mevzuata uygun olacak şekilde ve tadilata yönelik olarak;

• Binanın mevcut durumunu ifade eden ve kullanım mahallerinin belirlendiği rölöve projelerinin ve ön projelerinin hazırlanması,

• Mimari, statik, mekanik ve elektrik uygulama projelerinin hazırlanması,

• Tadilat işine yönelik, teknik şartnameler ile mahal listelerinin ve metraj çalışmalarının yapılması,

• Tadilat işine yönelik yaklaşık maliyetin tespit edilmesi,

bu işin kapsamıdır.

C- GENEL HUSUSLAR :

1. Bu iş kapsamında yapılacak işlere dair;

a. Tadilat Projesi İhtiyaç Listesi EK-A’da,

b. Tadilat Projesi Hazırlama Kriterleri EK-B’de,

c. Kullanıcı Birliğe ait Mahal Krokileri EK-C’de,

ç. Kullanıcı Müdürlük İstek Raporu EK-Ç’de,

d. Zemin Etütleri Kontrol Listesi EK-D’de,

e. Örnek Proje Anteti EK-E’de,

f. Örnek Yeni Fiyat Analizi Formatı EK-F’da,

g. Teknik Şartname Formatı EK-G’de ,

ğ. Ödeme Pursantaj Tablosu EK-Ğ’de bulunmaktadır.

2. Proje Hizmet Alımı kapsamında, EK-A’da listelenen proje, doküman, rapor, belge vs.’nin hazırlanması istenmektedir. Projeler, EK-B’deki Tadilat Projesi Hazırlama Kriterlerine ve

TASNİF DIŞI 1

Page 3:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

yürürlükteki mevzuata (Anayasa, kanun, kanun hükmünde kararname, tüzük, yönetmelik, tebliğ) uygun olarak hazırlanacaktır.

3. Elektronik Atölyeleri mahalleri, Kullanıcı Birlik tarafından hazırlanmış ve EK-C’de verilen krokide gösterilen mahaller dikkate alınarak eski Galvaniz Atölyesi Binasının içinde konuşlanacaktır.

4. Eski Galvaniz Atölyesinin tadil edilmesi ile oluşacak Elektronik Atölyeleri Binası, EK-Ç’de sunulan Kullanıcı Müdürlük İstek Raporuna (Teknik, fen ve yürürlükteki mevzuatın öngördüğü sınırlar içinde) tasarlanacaktır. Ayrıca;

a. Mevcut bina içerisinde yapılacak olan onarımların düzeyi ve onarıma yönelik imalatın uygulama biçimi idarenin görevlendirdiği proje kontrol mühendisleri ile birlikte yerinde tespit edilecektir.

b. Onarım düzeyinin tespiti konusunda değerlendirilen inşai imalatlar ile birlikte mekanik ve elektrik tesisatına yönelik hususlar için tespitlerde bulunacaktır.

c. İş kapsamında hazırlanacak olan projelerde, kullanılacak taşıyıcı sistem dizaynında, ofis kısımlarının çelik konstrüksiyon çerçeve sistem olarak, zemin kısmında betonarme taşıyıcı olacak şekilde dizayn edilmesine dikkat edilecektir.

d. Kullanılacak çelik konstrüksiyon ve betonarme taşıyıcı sistemlerine ait statik ve dinamik hesap dosya çıktıları, düğüm noktası hesapları vb. tüm hesaplar kitapçık haline getirilerek statik projesi ile birlikte sunulacaktır.

e. Mimari projelerin içeriğinde uygulama detayları ve görünüşler yürürlükteki mimari proje hazırlama esaslarına göre düzenlenecektir.

f. Elektrik ve Mekanik tesisatına ilişkin uygulama projelerin hazırlanmasında mevcut binanın beslendiği altyapılar göz önünde bulundurularak gerekli bağlantı ve dağıtımlar yapılacaktır.

g. Çelik konstrüksiyon projelerin hazırlanma esaslarını içeren yürülükteki mevzuatın içeriğinden proje müellifi sorumlu olacak ve projelerini bu doğrultuda hazırlayacaktır.

5. Zemin Etüt Raporlarında olması gereken hususlara dair “Kontrol Listesi” EK-D’de olup, yüklenici tarafından teslim edilecek zemin etüt raporları İstanbul Tersanesi Komutanlığı Kontrol Teşkilatınca bu kontrol listesine göre incelenecektir. Aynı zamanda söz konusu zemin etüt raporları yasal mevzuat gereği Jeofizik Mühendisine imzalatılacak ve Jeofizik Mühendisleri Odasına onaylattırılacaktır.

6. Projeler, hesap raporları ve zemin etüt raporları Mart 2007 Deprem Bölgelerinde Yapılacak Binalar Hakkındaki Yönetmelik(DBYBHY) 2.13 maddesinde belirtilen “Deprem Hesap Raporlarına”, 3.13 maddesinde belirtilen “Betonarme Uygulama Projesi Çizimlerine İlişkin Kurallar“, 4.10 maddesinde belirtilen “Proje Hesap Raporu ve Uygulama Projelerine İlişkin Kurallar” ile 6.2 maddesinde belirtilen “Zemin Koşullarının Belirlenmesi” başlıkları önde gelmek üzere DBYBHY‘ye uygun olarak tanzim edilecektir.

7. Proje müellifinin hazırlayacağı projeler konusunda yetkili olduğuna dair büro tescil belgesi idareye teslim edilecektir.

TASNİF DIŞI 2

Page 4:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

8. Proje Antetleri EK-E’deki örneğe uygun olarak hazırlanacaktır ve her paftanın başında yer alacaktır. Antet üzerinde proje müellifinin adı, soyadı, unvanı, oda sicil numarası ve imzası bulunacaktır. İdarenin imzalayacağı haneler daha sonra kaşelenmek üzere boş bırakılacaktır.

9. Proje ozalitlerinin katlanmış durumdaki boyutları (30x21) cm. olacaktır. Projelerin hesap raporları, sayfa ekleme veya çıkartmaya imkân tanımayacak şekilde ciltli olarak hazırlanacaktır. Hesap raporlarının kapak sayfasında proje müellifinin firma ismi ile yapan personelin adı-soyadı, imzası bulunacaktır.

10. İş programı , Yer Tesliminden İtibaren 5 takvim günü içerisinde 4 nüsha halinde İdarenin onayına sunulacaktır.

11. Proje üretiminin iş programına uygun olması sağlanacak, işte süre uzatımı olması halinde revize iş programı tekrar hazırlanıp, idare onayına sunulacaktır.

12. Projeler İstanbul Tersanesi Komutanlığına ilk etapta tek nüsha olarak üst yazı ile teslim edilecektir. Teslim edilen projelerde idare tarafından yapılan düzeltme/değişiklikler projelere işlenerek, düzeltilmiş projeler muntazam dosyalar içinde İstanbul Tersanesi Komutanlığına onay için teslim edilecektir.

13. İdarece ve yüklenici tarafından üretilen proje/dokümanlarda değişiklik yapılması gerekli görüldüğü ve/veya verilen bilgiler yeterli görülmediği takdirde, projelerde ve ilgili dokümanlarda istenen değişikliklerin yapılması ve/veya eksik bilgilerin tamamlanması için proje/dokümanlar, istenenlere uygun şekle getirilmek üzere yükleniciye iade edilecektir. Söz konusu değişiklikler için yükleniciye ayrıca bir ödeme yapılmayacaktır.

14. Projelendirme çalışmaları esnasında tespiti mümkün olmayan ve/veya yüklenici tarafından, tespit edilemeyen hususların imalat aşamasında ortaya çıkması durumunda; anılan projeler tespit edilen yeni hususları da kapsayacak şekilde proje müellifi tarafından bedelsiz revize edilecek ve gerekli görüldüğü takdirde yeni proje ve detaylar üretilerek idarenin onayına sunulacaktır.

15. Yüklenici, tüm etüt, analiz, projelendirme ve detay çalışmaları yürürlükte olan kanun, yönetmelik, standartlar ve tüm teknik icaplara uygun olarak hazırlamak zorundadır. Yüklenici, yapacağı proje ve hesapların eksiklik ve yanlışlıklarından ve bunların sonuçlarından sorumludur. Yüklenici, projelerin ve hesapların hazırlanabilmesi için gerekli her türlü bilimsel, teknik ve ekonomik bilgiye vakıf olduğunu ve ehliyetli personel çalıştırdığını taahhüt eder. Hazırlanan proje, hesap ve dokümanların teknik icaplara uygun olmaması ve idarenin ihtiyacına elverişli olmaması durumunda, hata veya kusurun düzeltilmemesi ve eksikliklerin tamamlanmaması halinde yüklenici, idarenin müspet ve menfi zararlarını tazmin etmekle yükümlüdür.

16. Yüklenicinin hizmet aldığı uzmanlarından herhangi biri, işin herhangi bir safhasında kendisine ait hizmetleri yapmaktan sarfı nazar ettiği takdirde yüklenici aynı hizmeti idarenin kabul edeceği başka bir uzmana yaptırmaya mecburdur. Aksi halde idare, sözleşmeyi feshe ve gereğini ilgili mevzuat hükümlerine göre yapmaya yetkilidir.

17. Mimari uygulama projeleri, metraj hazırlanırken kullanılacak imalat pozları öncelikle Çevre ve Şehircilik Bakanlığına ve Milli Savunma Bakanlığına (MSB) ait pozlar olacak, ilgili imalatın karşılığının bu pozlar arasında bulunamaması halinde diğer kamu kurum ve kuruluşların pozları esas alınacaktır. İmalatın kamu kurumları tarafından yayımlanan pozlar arasında bulunmaması halinde, idarenin göstereceği formata uygun olarak, işin uzmanı 3 firmadan alınacak rayiç proforma faturalarla, EK-F’deki formatta, yürürlükteki mevzuat paralelinde yeni fiyat analizleri hazırlanıp, idarenin onayına sunulacaktır.

TASNİF DIŞI 3

Page 5:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

18. Altyapı Projeleri (Elektrik, Su Drenaj, Isı Merkezi, Basınçlı Hava, Bağlantı Yolu, Trafo, Jeneratör Binası, İhtiyaç varsa Su Deposu ve havuzu, Kanalizasyon Bağlantısı, Kanalizasyon hattı yoksa Fosseptik veya Arıtma Tesisi Yapılması), proje müellifi, İstanbul Tersanesi Komutanlığı Kullanıcı Müdürlüğü ve Kontrol Teşkilatı arasında yapılacak koordineleri içeren 3 nüsha tutanak doğrultusunda hazırlanacaktır. Hazırlanan tutanakların 1 nüshası Kullanıcı Müdürlüğe verilecek, 1 nüshası Kontrol Teşkilatınca muhafaza edilecek, kalan 1 nüshası proje müellifine ait olacaktır.

19. İhtiyaç olduğu takdirde ,altyapı projeleri ilgili kurum ve kuruluşların (Çevre ve Şehirçilik Bakanlığı, İller Bankası, TEDAŞ vb.) teknik şartnamesine göre hazırlanacaktır. Binanın kurulu gücünün belirlenmesini müteakip gerekli olduğu takdirde enerji getirme projeleri kapsamında trafo projeleri hazırlanarak ilgili enerji dağıtım şirketine (TEDAŞ vs.) onaylatılacaktır.

20. Proje müellifi, proje uygulamasından dolayı telif hakkı talebinde bulunamaz. Yapılan ihale, proje yaptırılması ve her türlü hakkının satın alınmasıdır.

21. İşe ait yapı ruhsatının yapım işinin yüklenicisi tarafından alınacağı, proje müellifi tarafından teknik şartnameye yazılacaktır.

22. Tadilat yapılarak Elektronik Fabrikası binası olarak revize edilen binaya Enerji Kimlik Belgesi düzenlenecektir. Enerji Kimlik Belgesi düzenlenmesi sonrası mevcut yönetmeliklere aykırı hususlar için ilgili bütün projelerde yeniden revize yapılacaktır.

23. İnşaatın yapılacağı alanı gösteren panoramik fotoğraflar proje müellifi tarafından idarenin isteyeceği sayıda çekilerek 4 takım fotoğraf albümü halinde idareye teslim edilecektir.

24. Projelendirme faaliyetleri 3 ana gruptan oluşacaktır;

• Röleve Proje Safhası

• Uygulama ve Detay Projeleri ile Mahal Listesi ve Teknik Şartname Safhası

• Metraj, Keşif ve Yaklaşık Maliyet Safhası

25. Röleve Proje Safhası kendi içinde;

• Mimari röleve projelerin ve öneri raporunun hazırlanması ( 1/100 )

• Makine tesisat öneri raporunun ve röleve projelerinin hazırlanması (1/100 )

• Elektrik tesisatı öneri raporunun ve röleve projelerinin hazırlanması (1/100) alt gruplarından oluşur.

26. Kesin Proje Safhası kendi içinde;(Kesin Proje bu iş kapsamında istenmemektedir.)

• Mimari kesin projelerin hazırlanması ( 1/100 )

• Makine tesisat kesin projelerin hazırlanması (1/100 )

• Elektrik tesisatı kesin proje hazırlanması ( 1/100 ) alt gruplarından oluşur.

27. Uygulama ve Detay Projeleri ile Mahal Listesi ve Teknik Şartname Safhası kendi içinde;

TASNİF DIŞI 4

Page 6:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

• Mimari uygulama ve detay projelerin hazırlanması ( 1/50-20-10-5-1 )

• Statik uygulama ve detay projelerinin hazırlanması ( 1/50-20-10-5-1 )

• Makine tesisat uygulama ve detay projelerinin hazırlanması (1/50-20-10-5-1 )

• Elektrik tesisatı uygulama ve detay projelerinin hazırlanması (1/50-20-10-5-1) alt gruplarından oluşur.

• Mahal Listesi hazırlanması

• Teknik Şartname hazırlanması

28. Metraj, Keşif ve Yaklaşık Maliyet Safhası kendi içinde;

• Metrajların hazırlanması,

• Yeni fiyat analizlerinin hazırlanması,

• Yaklaşık Maliyetin hazırlanması,

• İhale dökümanlarını içeren tüm konuları içeren dökümanların lisanslı Yaklaşık Maliyet hazırlama programı ile çıktı alınarak ve ihaleye esas olmak üzere elektronik ortamdaki CD’nin yüklenici ve idare için 4 (dört)'er takım halinde hazırlanması ve idareye teslim edilmesi, alt gruplarından oluşur.

Projeler hazırlanırken sadece “İhtiyaç Listesinde“ belirtilenler hazırlanacaktır.

29. İstanbul Tersanesi Komutanlığınca yaptırılan proje hizmet alımlarındaki koordine ve onay süreçleri ile ilgili olarak;

a. Röleve Proje Safhasındaki projelerin 1 takım hazırlanarak idareye teslimi sonrası, Kontrol Teşkilatınca incelenmeleri, varsa düzeltmelerin proje müellifince yapılması ve uygun görülmeleri halinde Röleve projesi düzenlenerek 4 takım halinde idareye teslim edilecek ve Uygulama Projesi Safhasına geçilecektir.

b. Uygulama ve Detay Projeleri ile Mahal Listesi ve Teknik Şartname Safhasındaki projelerin-dokümanların hazırlanarak 4 takım olarak idareye teslimi sonrası, Kontrol Teşkilatınca incelenmeleri, varsa düzeltmelerin proje müellifince yapılması ve uygun görülmeleri halinde İstanbul Tersanesi Komutanlığınca onaylanmasını müteakip, koordine ve onay alınması için MSB İstanbul İnşaat Emlak Bölge Başkanlığına gönderilecektir..

c. MSB İstanbul İnşaat Emlak Bölge Başkanlığınca projelerde düzeltme ihtiyacı bulunması halinde söz konusu düzeltmeler proje müellifince derhal yapılacaktır. Düzeltmelerin niteliği projenin özüne tesir edecek düzeyde olması halinde düzeltme sonrası uygulama ve detay projeleri ile mahal listesi ve teknik şartname yeniden MSB İstanbul İnşaat Emlak Bölge Başkanlığına koordine için sevk edilecektir. Düzeltmelerin projenin özüne tesir edip etmediğine dair karar Kontrol Teşkilatınca verilecektir.

ç. Düzeltme bulunmaması halinde/Düzeltmeler sonrası, Metraj, Keşif ve Yaklaşık maliyet Safhasına geçilecektir.

TASNİF DIŞI 5

Page 7:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

30. Her safhada istenen projelerin hazırlanarak İstanbul Tersanesi Komutanlığına sunulması sonrası, sunulan projelerin Kontrol Teşkilatınca incelenmeleri süresi 10 gündür. Bu süreye her safhada tespit edilen düzeltme ihtiyaçlarının proje müellifince giderilmesi süresi dahil değildir. Uygulama ve Detay Projeleri ile Mahal Listesi ve Teknik Şartname Safhasındaki MSB İstanbul İnşaat Emlak Bölge Başkanlığına koordine süreci 30 gündür. Bu süre evrağın İstanbul Tersanesi Komutanlığından çıkış tarihinden itibaren MSB İstanbul İnşaat Emlak Bölge Başkanlığının koordinesinden sonra İstanbul Tersanesi Komutanlığına evrağın girdiği zamana kadar geçen süredir. MSB İstanbul İnşaat Emlak Bölge Başkanlığının koordine süreci ile her safhanın Kontrol Teşkilatınca koordine edilmesi süreçlerinin belirlenen zamanları aşması ve proje müellifinin süre uzatımı talep etmesi halinde, idare tarafından süre uzatımı verilebilir.

31. Her safhadaki projelerin/dokümanların tamamının (Mimari, Statik, Makine, Elektrik) İstanbul Tersanesi Komutanlığına teslim edildiği (Yüklenici dilekçesinin Genel Evrak’a giriş tarihi) en son tarih giriş tarihidir.(Örneğin, Röleve Proje Safhasından en son makine röleve projeleri teslim edilmiş ise makine röleve projelerinin genel evrak giriş tarihi, Röleve Proje Safhasının idareye teslim tarihidir.)

32. Her Safhadaki Projelerin (Mimari, Statik, Makine, Elektrik) koordine/onay için gönderilen, MSB İstanbul İnşaat Emlak Bölge Başkanlığından en son gelen ve/veya Kontrol Teşkilatınca koordine edilerek İstanbul Tersanesi Komutanlığınca proje müellifince bildirilen üst yazı tarihi bildirim tarihi olarak kabul edilecektir. (Örneğin, Uygulama Proje Safhasındaki MSB İstanbul İnşaat Emlak Bölge Başkanlığınca koordine edilerek gelen en son elektrik uygulama projesinin İstanbul Tersanesi Komutanlığınca proje müellifine bildirim tarihi Uygulama Proje Safhası için proje müellifine bildirim tarihidir.)

33. Proje Hizmet Alımı işinin Hizmet Kabulünün yapılmasından sonra hakediş ödemesi tek seferde yapılacaktır.

34. Mimari projeler hazırlanırken planlar, kesitler ve görünüşlerde tüm imalat kalemleri pozlandırılarak detaylı bir biçimde paftalara işlenecektir.

35. Tadil edilecek bina/tesislerin 4 takım halinde 1/100 ölçeğinde Mimari Röleve Projeleri hazırlanarak İstanbul Tersanesi Komutanlığına onay için sunulacaktır.

Mimari Röleve Proje hazırlanırken EK-B Mimari Röleve Proje Hazırlama Esaslarında belirtilen hususlar göz önüne alınacaktır. Röleve proje kapsamında binanın mevcut durumu, vaziyet planı, kat planları ile kesit ve görünüşleri, cepheleri ve çatı sistemi bulunacaktır.

36. Kontrol heyeti tarafından gerekli düzeltmeler yapılarak onaylanan Röleve projeler doğrultusunda 1/50-1/20-1/10-1/5-1/1 ölçeklerinden uygun olanlarıyla Uygulama ve Detay Projeleri EK-B doğrultusunda düzenlenerek 4 takım halinde İstanbul Tersanesi Komutanlığının onayına sunulacaktır. Uygulama projeleri hazırlanırken Milli Savunma Bakanlığınca verilen münferit emirler doğrultusunda tip kesit / detay / uygulamalara göre hareket edilerek planlarda, kesitlerde ve görünüşlerde tüm imalat kalemleri pozlandırılarak detaylı bir şekilde paftalara işlenecektir. Yüklenici uygulama projelerini esas alarak metraj ve tanımı belli olmayan işler için imalat tarifi / analizler hazırlayacaktır.

37. İhtiyaç listesinde belirtilen “Yüklenici CD’ sinin” içinde işe ait teknik şartname ile uygulama projeleri ve mahal listesi olacaktır. Yine ihtiyaç listesinde belirtilen “İdare CD’sinin” içinde işe ait teknik şartname, Röleve ve uygulama projeleri ile detay projeleri, teknik şartname, mahal listesi, işin metrajı, içinde bulunan yılın fiyatlarıyla hazırlanmış keşfi (işin maliyeti) bulunacaktır.

TASNİF DIŞI 6

Page 8:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

38. Bu iş kapsamında yüklenici firma tarafından 1(bir) adet mimar, 1(bir) adet inşaat mühendisi, 1(bir) adet makine mühendisi ve 1(bir) adet elektrik mühendisi teknik personel olarak istenmektedir.39. Yüklenici, proje konusu iş ile ilgili beyan ettiği teknik personelin(Mimar, İnşaat Mühendisi, Makine Mühendisi, Elektrik Mühendisi vb. ilgili mühendislik odalarına kayıtlı olduğunu belgelendirilecektir.

40. Yukarıda istenen teknik personelin işin süresi boyunca SGK primlerinin yattığına dair belge ibraz edildikten sonra hakediş ödenecektir.

EKLER :EK-A ( Tadilat Projesi İhtiyaç Listesi)EK-B ( Tadilat Projesi Hazırlama Kriterleri)EK-C ( Kullanıcı Birliği ait Mahal krokileri)EK-Ç ( Kullanıcı Müdürlük İstek Raporu)EK-D ( Zemin Etütleri Kontrol Listesi) EK-E ( Örnek Proje Antetleri)EK-F ( Örnek Yeni Fiyat Analizi Formatı)EK-G ( Teknik Şartname Formatı)EK-Ğ ( Ödeme Pursantaj Tablosu)

HAZIRLAYANLAR TETKİK EDENLER

TASNİF DIŞI 7

(İ M Z A L I)

Emine AKTAŞ Mimar

(İ M Z A L I)

Sevim BEEL Elk.Müh.

(İ M Z A L I)

Müşfik ÜSTÜNAY Mak.Müh

(İ M Z A L I)

Bahadır DOĞRUSÖZ İnş.Yük.Müh.

(İ M Z A L I)

Alp SEZENER İnş.Yük.Müh.

(İ M Z A L I)

M.Göksel KAVAS Müh.Bnb. Plan Keşif Amiri

(İ M Z A L I)

Ceyhan TEZCAN Deniz Albay Bayındırlık Müfürü

(İ M Z A L I )

Ahmet ÇAKIR

Tümamiral

İstanbul Tersanesi Komutanı

ONAY 09/01/2017

Page 9:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

EK-ATADİLAT PROJESİ İHTİYAÇ LİSTESİ

GALVANİZ BİNASININ TADİL EDİLEREK AMBAR/ ATÖLYE HALİNE GETİRİLMESİ PROJE HİZMET ALIMI

1. RÖLEVE PROJELERGalvaniz Binasının Tadil Edilerek Ambar/Atölye Haline Getirilmesi Röleve Projelerin

Hazırlanması (1/100 ölçekli) (4 Takım)

a. Mimari Röleve projelerin hazırlanması

(1)Vaziyet Planı (1/200 ölçekli)(4 Takım)

(2)Plankote (1/100 ölçekli)(4 Takım)

(3)Mimari Rölöve Proje (1/100 ölçekli)(4 Takım)

Rölöve Çatı Planı Rölöve Kat Planı Rölöve Kesit ve Görünüşler Rölöve Mahal Listesi

b. Makine tesisat röleve projelerinin ve öneri raporunun hazırlanması(1)Makine Tesisatı Rölöve Projesi (1/100 ölçekli)(4 Takım)

• Tavan Kreyn Rölöve Projesi • Havalandırma Rölöve Projesi • Isıtma Sistemi Rölöve Projesi (2)Makine Tesisatı Öneri Raporu

Raporda, mevcut mekanik tesisatının durumu hakkında inceleme sonuçları resimli olarak anlatılacak ve tadilat kapsamında ihtiyaç duyulan makine tesisatına yönelik yapılması gereken işlemler, öneriler(onarım, yeni tesisat çekimi, vb.) sunulacaktır.

Mevcut Kreynin durumu resimli olarak raporda anlatılacak, onarım veya yenisinin imalinden hangisinin efektif olacağı hakkında tetkik yapılacak ve öneri raporunda bildirilecektir.

c. Elektrik tesisatı öneri raporunun hazırlanması

(1)Elektrik Tesisatı Rölöve Projesi (1/100 ölçekli)(4 Takım) Aydınlatma Tesisatı Planı Priz Tesisatı Planı Mekanik Tesisat Kuvvet Planı Tablo ve Pano Besleme Planı Kablo Taşıma Planı (PVC ve Tava) Topraklama ve Yıldırımdan Koruma Tesisatı Planı

TASNİF DIŞI A-1

Page 10:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(2)Elektrik Tesisatı Öneri RaporuRaporda, mevcut elektrik tesisatının durumu hakkında inceleme sonuçları resimli

olarak anlatılacak ve tadilat kapsamında ihtiyaç duyulan elektrik tesisatına yönelik yapılması gereken işlemler, öneriler(onarım, yeni tesisat çekimi, vb.) sunulacaktır.

Mevcut faraday kafesli yıldırımdan koruma tesisatının durumu resimli olarak raporda anlatılacak, onarım veya yenisinin yapılmasından hangisinin efektif olacağı hakkında tetkik yapılacak ve öneri raporunda bildirilecektir.

2. UYGULAMA VE DETAY PROJELERİ İLE MAHAL LİSTESİ VE TEKNİK ŞARTNAME

a. Mimari Uygulama ProjeleriGalvaniz Binasının Tadil Edilerek Ambar/Atölye Haline Getirilmesi Mimari Uygulama

projelerinin hazırlanması

(1)Mimari Uygulama ve Detay Projelerin Hazırlanması (1/50, 1/20, 1/5, 1/1 ölçeklerinden uygunu) (4 Takım)

(a) Kat Planlarının Hazırlanması (1/50 ölçeğinde)

(b) Kesitlerin Hazırlanması (1/50 ölçeğinde)

(c) Görünüşlerin Hazırlanması (1/50 ölçeğinde)

(ç) Çatı Projelerinin Hazırlanması (1/50)

(d)Mahal Listenin Hazırlanması (Poz Numaraları üzerine yazılı vaziyette)

(e) Detayların Hazırlanması (1/20, 1/5, 1/1 ölçeklerinden uygunu)

Sistem Detayların Hazırlanması (1/20, 1/5, ölçeklerinden uygunu)

Islak Hacim Detaylarının Hazırlanması (1/20, 1/5 ölçeklerinden uygunu)

Doğrama Detaylarının Hazırlanması (1/20, 1/5 ölçeklerinden uygunu)

Çatı Detaylarının Hazırlanması ( 1/50, 1/20, 1/5 ölçeklerinden uygunu)

Mantolama Detaylarının Hazırlanması (1/20, 1/5, 1/1 ölçeklerinden uygunu)

Merdiven Detayların Hazırlanması (1/20, 1/5, 1/1 ölçeklerinden uygunu)

Ana Bina Çatı Kaplaması ve Dere detaylarına ait imalat nokta detaylarının

Hazırlanması (1/20-1/10-1/5-1/2-1/1 uygun olan ölçeklerde)

İzolasyon, döşeme detaylarının hazırlanması (1/50, 1/20, 1/5, 1/1

ölçeklerinden uygunu)

(2) Çevre Tanzim Projelerin Hazırlanması (üzerinde 1/20 sistem detayları ile 1/5, 1/1 nokta detayları da bulunacaktır.) ( 1/500, 1/200 ölçeklerinde) (4 Takım)

TASNİF DIŞI A-2

Page 11:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

• Bina giriş ve çıkışlarını kumanda eden yollar ile bu yolların altyapısını oluşturan proje paftalarının hazırlanması. (1/100-1/50-1/20-1/5-1/1 ölçeklerinden uygun olan seçilerek)

• Çevre düzenlenmesi projelerinin hazırlanması (1/100-1/50-1/20-1/5-1/1 ölçeklerinden uygun olan seçilerek)

(3)İnşaat Teknik Şartnamesinin HazırlanmasıMimari ve inşai imalatların poz numaralarını içeren ve imalat kalemlerinin bulunduğu

detaylı şekilde tariflerin yapıldığı, ihtiyaç duyulduğu takdirde imalat tip şekillerin gösterildiği İnşaat Teknik Şartnamesi hazırlanacaktır.

b. Statik ve Altyapı ProjeleriGalvaniz Binasının Tadil Edilerek Ambar/Atölye Haline Getirilmesi Statik ve Altyapı

Projelerin hazırlanması (1/50-1/10-1/5-1/2 ölçekli) (4 Takım)

(1)Zemin etütlerinin yapılması ve rapor haline getirilmesi 5 (beş) adet 12m boyunda sondaj yapılarak, bunlara ait testlerin laboratuvarda

yaptırılması, rapor haline getirilip yasal mevzuatta yer alan mühendislerin ve ilgili meslek odalarının ve üniversitelerin ilgili bölümlerinden onay alınması işlerini kapsar. (4 Takım)

(2)Statik Projelerin Hazırlanması (1/50 ölçekli) (4 Takım)Statik Uygulama Projelerinin ana ölçeği 1/50 olacaktır.Ancak detayların anlaşılabilir

olmasına bağlı olarak 1/20-1/10-1/5-1/2-1/1 ölçekleride kullanılabilecektir.

(a) Statik Hesap Raporunun Hazırlanması (4 Takım)

Mevcut ana binanın temel onarımını içeren statik hesap raporları

Mevcut ana binanın çatı konstrüksiyonunun onarımını içeren statik hesap raporları

İç kısıma yapılacak olan mahallerin taşıyıcı sisteminin statik hesap raporları

Çelik Konstrüksiyon (kaynak-bulon-perçin vb ) düğüm noktası hesaplarının raporları

(b) Temel Kalıp Planının Hazırlanması (1/50 ölçekli)

(c) Temel Donatı Planının Hazırlanması (1/50 ölçekli)

(d) Çelik Kolon Aplikasyon Planının Hazırlanması (1/50 ölçekli)

(e) Çelik Konstrüksiyon Kolon-Kiriş-Döşeme Planının Hazırlanması (1/50 ölçekli)

(f) Çelik Konstrüksiyon Kiriş- Betonarme Döşeme Kalıp Planının Hazırlanması (1/50 ölçekli)

(g) Betonarme Döşeme Donatı Planının Hazırlanması (1/50 ölçekli)

(h) Betonarme Döşeme-Çelik Konstrüksiyon Kiriş Bağlantı Detaylarının Hazırlanması (1/50 )

(i) Çelik Konstrüksiyon Kiriş Bağlantı Detaylarının Hazırlanması (1/50 ölçekli)

(j) Çelik Kolon Bağlantı Detaylarının Hazırlanması (1/50 ölçekli)

TASNİF DIŞI A-3

Page 12:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(k) Çatı Konstrüksiyonu Planının ve nokta ve kesit detaylarının Hazırlanması (1/50 ölçekli)

(3)Altyapı Projesi Hazırlanması Binaya getirilecek elektrik besleme, telefon, data, su, kanalizasyon, yağmur suyu

hatları ve rögarları, ısı, doğalgaz hatları için gerekli beton/betonarme galeri ve/veya toprakaltı baca, rögar gibi yapıların en/boy/ kesit ve detaylarını kapsar. (1/500, 1/200, 1/50, 1/20, 1/5, 1/1 ölçekli) (4 Takım)

c. Makine Tesisat Uygulama Projelerinin HazırlanmasıGalvaniz Binasının Tadil Edilerek Ambar/Atölye Haline Getirilmesi Mekanik Tesisat

Uygulama ve Detay Projelerin Hazırlanması (1/50 ölçekli) (4 Takım)

(1)Sıhhi Tesisat (Temiz Su Tesisatı, Pis Su Tesisatı, Kullanma Sıcak Su Tesisatı) Projesinin Hazırlanması

(2)Isı Yalıtımı Hesabının Yapılması, Isıtma Tesisatı (Kalorifer Tesisatı) Projesinin Hazırlanması

(3)Yangın Tesisatı Projesinin Hazırlanması

(4)Havalandırma Projesinin Hazırlanması

(5)Vaziyet Planında Altyapı Bağlantılarının Gösterilmesi (Isı, temiz su, pis su, yangın, basınçlı hava vb. )

(6) Basınçlı Hava Tesisatının Hazırlanması (Tesisatta kurutucu düşünülecektir.)

(7)Hesap Raporunun Hazırlanması

(8)Mevcut Kreynin bakım ve onarımına ait teknik rapor neticesi yapılacak işlemin teknik şartnameye ve yaklaşık maliyete eklenmesi, onarım projesinin veya gerek duyulması halinde yeni kreyn projesi ve maliyeti hazırlanması (Konstrüksiyon ve raylar dahil)

(9)Makine Teknik Şartnamesinin Hazırlanması

ç. Elektrik Tesisat Uygulama Projelerinin HazırlanmasıGalvaniz Binasının Tadil Edilerek Ambar/Atölye Haline Getirilmesi Elektrik Tesisat

Uygulama ve Detay Projelerin Hazırlanması (1/50 ölçekli) (4 Takım)

(1)Elektrik Kuvvetli Akım Tesisatı Projesi (1/50 ölçekli) Aydınlatma Tesisatı Planı Priz ve UPS Tesisatı Planı Mekanik Tesisat Kuvvet Planı Priz Kutusu Tesisat Planı Tablo ve Pano Besleme Planı AP-380/220V 50 Hz Panosu Kolon Şeması AP-115/65V 400 Hz Panosu Kolon Şeması (Mevcut Jenaratör/İnverter/Konverter

Kullanılacak Şekilde)

TASNİF DIŞI A-4

Page 13:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

Kablo Taşıma Planı (PVC ve Tava) Ana Kolon ve Tek Hat Şeması, Yükleme Cetveli

(2)Topraklama ve Yıldırımdan Korunma Tesisatı Projesi (1/50 ölçekli) Topraklama Tesisat Planı (Bina İçi Her Kullanıcı Masasına Olacak Şekilde) Topraklama ve Paratoner Tesisat Planı

(3)Zayıf Akım Tesisatı Projesi (1/50 ölçekli) İnternet, İntranet ve Telefon Tesisat Planı Yangın Algılama ve İhbar Tesisatı Planı Zayıf Akım Kolon Şeması

(4)Vaziyet Planı-Enerji Getirme Projesi (1/50 ölçekli) Vaziyet Elektrik Tesisat Planı Vaziyet Elektrik Kablo Güzergah Planı

(5)Elektrik Tesisat Teknik Şartnamesinin Hazırlanması

(6)Hesap Raporlarının Hazırlanması

3. METRAJ, KEŞİF VE YAKLAŞIK MALİYETGalvaniz Binasının Tadil Edilerek Ambar/Atölye Haline Getirilmesi Metraj, Keşif ve Yaklaşık Maliyet hazırlanması (4 Takım)

a. Metrajların Hazırlanması ( 4 Nüsha )

(1) İnşaat Metrajının Hazırlanması

• Kazı ve dolgu işine ait metraj listesi

• Yıkım ve söküm işine ait metraj listesi

• Tamir ve onarım işine ait metraj listesi

• Yeni yapım işine ait metraj listesi

(2) Makine Tesisat Metrajının Hazırlanması

(3) Elektrik Tesisat Metrajının Hazırlanması

b. Keşiflerin Hazırlanması ( 4 Nüsha )

(1) İnşaat Keşfinin Hazırlanması

(2) Makine Tesisat Keşfinin Hazırlanması

(3) Elektrik Tesisat Keşfinin Hazırlanması

c. CD Hazırlanması ( 4’er Adet)

(1)Yüklenici CD’sinin Hazırlanması

TASNİF DIŞI A-5

Page 14:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(2)İdare CD’sinin Hazırlanması

TASNİF DIŞI A-6

Page 15:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

EK-B

PROJE HAZIRLAMA KRİTERLERİ

Proje hizmet işlerinde uyulacak genel kriterler bu bölümde anlatılmış olup, proje hizmet alımlarında İhtiyaç Listesindeki(EK-A) istenen projeler hazırlanacaktır.Projelerin Düzenlenmesinde Dikkat Edilecek Hususlar:

1. Mimari Projelerin Hazırlanma Esasları2. Statik Projelerin Hazırlanma Esasları3. Elektrik Tesisatı Projelerin Hazırlanma Esasları4. Mekanik Projelerin Hazırlanma Esasları

1. Mimari Projelerin Hazırlanma Esasları

a. Mimari Avan Proje (Ön Proje) Hazırlama Esasları: Avan Proje aksi belirtilmedikçe 1/200 ölçekte hazırlanır.

Verilen ihtiyaç programı doğrultusunda Kullanıcı Müdürlükle koordineli olarak hazırlanıp, onay için 4 takım İstanbul Tersanesi Komutanlığına verilir.

Avan Proje, projenin yapıldığı yerdeki mevcut tesisler ile master planında bulunan tesisler göz önüne alınarak hazırlanır.

Avan Proje kapsamında Vaziyet Planı, Plankote, Kat Planları ile Kesit ve Görünüşler bulunur.

(1)Vaziyet Planlarını Hazırlama Esasları:(a)Yeni yapılacak bina ve tesislere ait Vaziyet Planı, yeni yapılacak bina ve tesislerin

etrafında bulunan binaları ve binalar arasındaki mesafeleri de gösterecek şekilde düzenlenir.

(b)Korunması gerekli görülen yeşil alan, ağaç, yol, duvar vb. ile arazide mevcut olan tüm yapı ve elemanların cins ve özellikleri, alt yapıya ait tüm bilgiler (kanal, boru, elektrik vb.) vaziyet planında gösterilir.

(c)Vaziyet Planı, yapılacak inşaatın veya tesisin özelliğine göre1/100-1/200- 1/500-1/1000 ölçekli olarak (temin edilebildiği takdirde) arazinin genel durumunu gösterir panaromik fotoğraflar ile korunması gerekli tesislere ait yakın mesafeden çekilen fotoğraflarla birlikte İdareye sunulur.

(d)Vaziyet Planlarında yön belirtilmesine mutlaka dikkat edilerek, teknik resim çizim standartlarına uygun sembol ile yön vaziyet planı üzerinde işaretlenir.

(e)Vaziyet Planlarında bölgede daha sonra yapılması düşünülen tesislerin de gösterilmesine, yerlerinin ve yaklaşık yapı izlerinin işaretlenmesi ile özelliklerinin belirtilmesine dikkat edilir.

(2)Plankote Hazırlama Esasları:(a)Plankote vaziyet planına uygun olarak hazırlanır. Yeni yapılacak tesisin inşaat

sahasında kalan mevcut yapı, yol, alt yapı tesisleri vb. plankotede mutlaka belirtilir. Röper noktası olarak yakın çevrede mevcut bulunan ve korunması gerekli herhangi bir yapıdan veya sabit bir noktadan yararlanılarak, yeni

TASNİF DIŞI B-1

Page 16:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

yapılacak inşaata, arazinin doğal durumuna ve mevcut tesislere uygun kot verilmesi sağlanır.

(b)İnşa edilecek bina için yer teslimi yapılan arazide siyah kotlar (doğal kotlar) sabit bir röper noktasına bağlanarak, arazi eğimi fazla olan yerlerde ara mesafeleri 2.5 m. olan karelajlar, arazi eğimi az olan yerlerde ara mesafeleri 5 m.lik karalejlar yapılarak yeterli bir uzaklığa kadar ihale bünyesinde yapılan tüm imalatları kapsayacak şekilde arazinin bütün kotları belirlenerek, arazinin büyüklüğüne bağlı olarak 1/100 veya 1/200 ölçeğinde düzenlenir. Plankotelerde vaziyet planına uygun olarak yön işareti mutlaka bulunur.

(c)Plankotelerde, bina girişleri, yol ve çevre kotları, zemin tesviye kotu (bitmiş imalat üst kotu), su basman kotu, zemin tesviye sınırı ile röper noktasının belirtilmesine özellikle dikkat edilir. Binaların birbirlerine olan uzaklıkları ile yola mesafeleri gösterilir.

(d)Plankotelerde; yol kotu, yer altı su kotu, kanalizasyon bağlantı kotu, içme suyu bağlantı kotu ve arazi eğimi göz önüne alınarak zemin tesviye ve kotu ile subasman kotu tespit edilir. Eğimi fazla olan arazilerde bina çevresinde kademeli hafriyat yapılması durumunda zemin tesviyesinden dolayı oluşacak istinat duvarları yükseklikleri belirtilerek plankoteye işaretlenir. (d) Belirlenen subasman kotu, tasdikli temel aplikasyon projesi ve zemin cinsine göre temel altı hafriyat kırmızı kotu tayin edilerek, hafriyat planı (şev durumu dahil) düzenlenir.

(e)Büyük arazi üzerine çok sayıda tesis yapılacaksa arazinin tümüne ait tesviye eğrili haritası çıkarılır.

(f) Plankotedeki tüm kotlar Harita Mühendisi tarafından alınıp paftaya işlenir. Proje müellifi mimar, yapılacak imalatlara göre araziyi değerlendirip, yapılacak imalat ve inşaat için Zemin Tesviye Kotu, Zemin Tesviye Sınırı ve Subasman Kotunu belirler.

(3)Çevre Tanzimi Projelerini Hazırlama Esasları:

(a)Tek bir binanın çevre tanzimi projesinde, binanın çevresindeki yollar ile ilişkisi vaziyet planına uygun olarak gösterilerek, arazi boyutları ile inşa edilecek binanın boyutları, yol genişlikleri ve bina ara mesafeleri belirtilir.

(b)Kuzey yönü kesinlikle belirtilir. Çizim standartlarına göre paftanın üst tarafı kuzey olacak şekilde, çevre tanzimi projesi düzenlenir.

(c)0.00 kotu, Araç ve yaya yolları, arazi ve bina köşe kotları ve tesviye kotu ayrı ayrı belirtilir.

(d)Yol durumu, bina veya tesislerde giriş çıkışlar, otopark, ağaçlık, yeşil alan, korunması gerekli kültür değerleri ve diğer sabit elemanlar gösterilir.

(e)Yeni yapılacak veya mevcut olan istinat ve ihata duvarlarının yükseklik, uzunluk ve özellikleri belirtilir.

(f) Çevre tanzimi detaylarında kullanılacak olan malzemelerin poz numaraları, cinsi ve yapılacak imalatın tarifleri mutlaka belirtilir.

(g)Çevre tanzim projesi, onaylı plankote göz önünde bulundurularak, kazı ve dolgular minimum tutulacak şekilde düzenlenir.

TASNİF DIŞI B-2

Page 17:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(h)Çevre tanzimi projeleri, ataşman kayıtlarına ihtiyaç bırakmayacak tarzda vaziyet planı ve plankoteye uygun olarak 1/200-1/500 ölçeğinde hazırlanır. Ayrıca 1/20-1/10 ve 1/5 ölçeğinde nokta detaylarını da ihtiva etmesi sağlanır.

a. Mimari Kesin Projelerin Hazırlanma Esasları:

Kesin projeler aksi belirtilmedikçe 1/100 ölçekte hazırlanır.

İstanbul Tersanesi Komutanlığınca onaylanmış Avan Proje doğrultusunda hazırlanır.

Kesin projede yapı sistemi, aks sistemi ve yapı elemanları belirlenmiş olmalıdır.

Kesin Projenin İstanbul Tersanesi Komutanlığı Kontrol Teşkilatınca incelenmesine müteakip koordine almak amacıyla Kullanıcı Müdürlüğe gönderilir. Uygun bulunan projeler İstanbul Tersanesi Komutanlığınca onaylanmasına müteakip Uygulama ve Detay Projeleri ile Mahal Listesi ve Teknik Şartname Safhası geçilir.

Kesin Proje kapsamında Vaziyet Planı, Kat Planları, Çatı Planı, Kesit ve Görünüşler ile Mahal Listesi bulunur.

b. Mimari Uygulama Projelerini Hazırlama Esasları:Yapının; inşa edilebilmesi için, statik projesinin tüm inşa ölçülerini, tesisat projesinin

inşaatı etkileyen bütün elemanlarını, imalat detaylarına uygun ölçü ve karakterde mimari elemanları, detaylarla ilgili referansları ve tüm detayları kendi çizim teknikleri ile eksiksiz ihtiva eden, gerekli bütün ölçülerin ve malzemenin ve açılımının yazıldığı; büro ve şantiyede her türlü çalışma ve imalat safhasında kullanılabilecek nitelikte ve kolayca anlaşılabilir çizim tekniği ile hazırlanmış, 1/50-1/20-1/10-1/5-1/1 ölçekli projesidir .

(1)Kat Planları:

(a)Zemin kat planında, yakın çevre ilişkileri gösterilir.

(b)Yapıdaki giriş ve çıkışlar (yangın, servis, kazan dairesi vs.) işaretlenerek kotlar yazılır.

(c)En ve boy kesitlerinin geçtiği yerler belirtilir. Binanın değişik bölgelerinden yeterli miktarda kesitler geçirilir.

(d)Taşıyıcı sistem aksları harfler ve rakamlar ile her iki yönde gösterilir.

(e)Dilatasyon olan kısımlara da aks numarası verilir.

(f) Bütün iç ölçüler, aralıklar ve kalınlıklar (duvar kalınlıkları, baca boyutları) belirtilir.

(g)Bütün dış ölçüler (doluluk, boşluk, cephe hareketleri ve blok ölçüleri) taşıyıcı akslar (yığma yapılar hariç) arası mesafesi belirtilerek gösterilir.

(h)0.00 kotuna göre her kat planı kotlandırılarak, varsa düşük döşeme kotları belirtilir.

(i) Merdiven sahanlıkları kotlandırılarak, merdiven çıkış yönü gösterilir. Ayrıca basamak adedi, rıht yüksekliği ve basamak genişliği paftaya yazılır. Merdiven küpeştesi iz olarak belirtilir.

TASNİF DIŞI B-3

Page 18:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(j) Denizlik ve parapet genişlikleri sıvadan 5 cm. sonra damlalık olacak şekilde belirtilir.

(k)Bütün mekanların isimlendirilmesi yapılarak, mahal numaraları verilir. Her mekanda iki yönde (enden ve boydan ayrı ayrı) iki ayrı ölçü çizgisi gösterilir. Birinci çizgide doluluk ve boşluklar ile hareketlilik ölçülendirilir. İkinci çizgide tam ölçü verilir.

(l) Kapı ve pencere boyutları gösterilerek, doğramaların bölümleri, açılan kısımları ve açılma yönleri ile kapıların açılış yönleri işaretlenir.

(m) Ofis, mutfak, banyo, lavabo ve WC’deki sabit ekipmanlar planlarda gösterilir.

(n)Binada tesis edilen bacaların bağlantı yönleri ve kesit ebatları belirtilir.

(o)Farklı yapı elemanları (kolon duvarı, perde, pano vb.) farklı çizim karakteri ile gösterilir.

(p)Isı Bölgeleri esas alınarak TS 825 Isı Yalıtım Yönetmeliğine uygun olarak Makine Tesisat Projesi ile koordineli şekilde yalıtım kalınlık ve cinsi tespit edilerek projelere işlenir.

(2) Kesitler:

Binanın en ve boy yönünde olmak üzere en az iki adet düşey kesiti çizilir. Bu kesitlerden en az biri merdiven veya kat arası düşey sirkülasyon elemanlarından geçmek üzere, bina genişliğince veya derinliğince ve bütün bina yüksekliğince (bodrum, normal çekme, tesisat katı ve çatı arası, asansör kulesi vb. dahil) çizilir. Kesitlerde, tüm kesit kotları eksiksiz olarak belirtilir.

(a)Taşıyıcı sistem farklı karakterde çizim ile gösterilir.

(b)Binaya ait özellikler (Çatı kaplaması, çatı arası imalat, döşeme, tavan, duvar kaplamaları ve açılımları) belirtilir.

(c)Binanın arsa üzerine oturduğu noktalardaki kotlar gösterilir.

(d)Kaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir.

(e)Sabit röpere göre görünüşe akseden pencere üstü, parapet, balkon korkulukları, merdiven sahanlıkları, saçak, çatı mahyası, baca, tretuvar vb. kotları gösterilir.

(f) Doğal zemin ve tesviye edilmiş zemin kotları belirtilerek, iki zemin farklı çizim karakteri ile gösterilir.

(g)Kat yükseklikleri ve kapı yükseklikleri ölçülendirilir.

(h)Pencere yükseklikleri ile pencerenin döşeme ve tavandan mesafelerinin ölçülendirilmesi ayrı boyut çizgisi üzerinde yapılır.

(i) Pencere parapet ve denizlikleri gösterilir.

TASNİF DIŞI B-4

Page 19:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(j) Çatı eğimi belirtilir.

(k)Zemine oturan döşemelerde duvarlarda ve tavanda TS 825 Isı Yalıtım Yönetmeliğine göre belirlenecek detay ve malzeme türleri paftaya işlenir.

(l) Bacaların, mahyadan yükseklikleri verilir. Isı merkezlerinin baca yükseklikleri Makine Tesisat Projelerinden alınır.

(m) Proje kapsamındaki tesisat boşlukları, aydınlık ve kanallar mutlaka gösterilir.

(n)Kesitlerde, dilatasyonların geçtiği yerler mutlaka belirtilir.

(3) Görünüşler:Görünüşler; ayrık nizamda bulunan binaların dört cephesi, bitişik nizamda buluna

binaların ise serbest kalan cepheleri esas alınarak plan ve kesitlerde belirtilmiş olan inşa esasları doğrultusunda hazırlanır. Paftalar; görünüş hareketlerini aksettirecek ve değişik malzemeleri farklı çizim tekniği ile ifade edecek şekilde çizilir. Görünüşlerde malzemelerin imalat tarifleri belirtilerek, tüm cephe kotları eksiksiz olarak gösterilir.

(a)Binanın zeminle irtibatını gösteren kotlar (pencere üstü, parapet, balkon korkulukları, saçak, çatı mahyası, baca vs.) plan ve kesitlerdeki değerlere uygun ve 0.00 kotuna bağlı olarak gösterilir.

(b)Doğal zemin ve tesviye edilmiş zemin kotlarının verilmesi ve her iki zeminin tüm görünüşlerde çizim farklılıkları ile belirtilmesi sağlanır.

(c)Zemin altında kalan kat döşemelerinin (bodrum, depo, sığınak vs.) ve farklılaşmaların çizim tekniklerine göre gösterilmesi ve kotlandırılması yapılır.

(d)Pencere, kapı, sabit kasa ve açılan kanatların doğramaları kat planlarına uygun şekilde ifade edilerek, açılma yönleri belirtilir.

(e)Tüm görünüş elemanları (korkuluk, denizlik, doğramaları cam, yağmur oluğu düşey yağmur boruları, baca vs.) gösterilir ve malzemelerin imalat tarifleri belirtilir.

(f) Planlara uygun olarak aks yerleri gösterilerek, aks numaraları ve dilatasyon yerleri işaretlenir.

(4) Sistem ve Nokta Detayları:

Mimari Uygulama Projelerinin tamamlanmasından sonra, imalatın projesi ve tekniğine uygun yapılabilmesi için ihtiyaç duyulan tüm noktalardaki (çatı, ıslak hacim, dilatasyon, merdiven, cephe, ısı yalıtım hesaplarına göre çatı, duvar, zemine oturan döşeme, kapı, pencere, dolap, tezgah vb.) detay çizimlerinin uygun ölçeklerde (1/20, 1/10, 1/5, 1/2, 1/1) yapılması gerekmektedir. Detay Çizimleri; plan, kesit ve görünüş çizimleri ile eksiksiz olarak tanımlanır.

TASNİF DIŞI B-5

Page 20:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(a)Yapının özellik ve karakteristiğini gösteren her bölümden plan, kesit ve görünüşlere uygun olarak 1/20 ölçeğinde sistem detayı verilir. (Cephe, giriş, ıslak hacim, merdiven vs.)

(b)Sistem detaylarında, tüm ölçüler plan kesit ve görünüşlere uygun olarak belirtilir. Yapıda kullanılan malzemeler, farklı çizim teknikleriyle gösterilerek ve malzeme cinsleri ve imalat tariflerine göre işlenir.

(c) Islak hacim sistem detayları plan-kesit-görünüş olarak hazırlanır. Kullanılan malzeme ve özellikleri tariflerine göre belirtilir. Duvar kaplamalarında kullanılan malzemelerin (fayans, seramik vb.) yükseklikleri çizim ile belirtilerek ayrıca üzerlerine ölçü verilir.

(d)Döşemelerde uygulanacak olan izolasyon vb. özellik arz eden imalatın cinsi belirtilir. Düşük döşemeler kesitlerde kot belirtilerek mutlaka gösterilir.

(e)Merdiven sistem detayları, yapının tüm katlarını kapsayacak şekilde plan ve kesit olarak hazırlanarak, basamak genişlikleri ile rıht yükseklikleri korkuluk yüksekliği, korkuluk malzemesi, ölçüleri (kalınlık, genişlik boy) ile cins ve özellikleri tam ve eksiksiz olarak belirtilir.

(f) Sistem detaylarında açık ve net olarak belirtilmeyen imalat için 1/10-1/5-1/2 ölçeğinde nokta detayları hazırlanır. Bu detaylarda tüm ölçüler gösterilerek, kullanılan malzemenin ve yapılacak imalatın özellikleri belirtilir.

(g)Çatı nokta ve sistem detaylarında ısı bölgelerine göre kullanılacak izolasyon malzemesinin cinsi ve kalınlığı mutlaka gösterilir. Saçak, baca dibi, sıva eteği, oluk vs. imalata ait kullanılan malzemenin ölçüleri ve imalat tarifleri açık ve net olarak belirtilir.

(h)Çatı Planı paftasına, yağmur iniş borusu hesabı yapılarak yağmur iniş borusu adedi ile yatay yağmur oluğu genişliği belirlenir.

(5) Mahal Listeleri:

(a)Mahal listeleri, mimari kat planlarına işlenen mahal numaralarına uygun olarak tüm mahalleri kapsayacak şekilde tablo halinde hazırlanır.

(b)Mahal listelerinde, döşeme, tavan ve duvarlarda kullanılan malzemelerin (kapı, pencere vs. özel imalat dahil) tümü eksiksiz olarak gösterilir.

2. Statik Projelerin Hazırlanma Esasları

a. Zemin Etütleri:

(1)Milli Savunma Bakanlığınca yaptırılmakta olan yapıların büyük bir çoğunluğunu askeri tesisler oluşturmaktadır. Bu tür yapılar I=1,4 yapı önem katsayısına sahiptir. Projeleri ihale usulüyle elde edilen veya farklı birimlerce projeleri hazırlattırılıp onay için gönderilen tüm işlerde Afet Bölgelerinde Yapılacak Yapılar Hakkında Yönetmelik uyarınca zemin etüdü yaptırılması zorunludur.

(2)İnşa edilecek yapılarda standardı sağlamak ve doğru zemin profilini tayin etmek için istenen kriterler hazırlanan şartnamelerde belirtilmelidir. Zemin profilinin çok değişmediği düz arazilerde iş kapsamında yer alan her bir bloğun oturma alanında ikiden az olmamak üzere kuru burgulu sistemle sondaj yapılır.

(3)Zemin Etütlerinde Uygulanacak Sondaj Derinliği ve Sondaj Sayısı için:

TASNİF DIŞI B-6

Page 21:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(a)Sondajda ana kayayla karşılaşıldığı takdirde bu tabakaya 3 m. girilecektir. Ana kaya çatlaklı bir özellik gösterirse, bu tabakada 5 m. ilerlenecektir.

(b)Sondaj zeminde devam ediyorsa, sondaj derinliği en az 12 m. olmak kaydıyla, 3 kez üst üste SPT-N > 50 değeri elde edilene kadar sondaja devam edilecektir. Sondaj derinliği hiçbir şekilde 12 metreden, bodrumlu binalarda 15 metreden, yapı yüksekliği on kat ve daha fazla ise 20 metreden az olamaz.

(c)Yukarıdaki şartlar geçekleşmezse sondaj derinliği bina kısa kenarının (B) 1,5 katı kadar olacaktır.

(d)Her bir sondaj kuyusuna, İdarenin kontrol edebilmesi maksadıyla, derinlik

boyunca delikli PVC boru bırakılacak ve her türlü dış etkiye karşı korunması için gerekli tedbir alınacaktır.

(e)Bina oturma alanı 500 m2 ve aşağısı ise 2 adet sondaj, 500 m2 ile 1000 m2 arası ise 3 adet sondaj, 1000 m2‟den fazla ise, alanın dört köşesinden 1‟er adet ve ortasından 1 adet olmak üzere toplam 5 adet sondaj yapılacaktır.

(f) Çok sayıda binanın oturduğu büyük alanlarda sondaj derinliği ve sayısına idare karar verecektir.

(4)Yapılacak laboratuvar çalışmaları sonucunda;

Zemin indeks özellikleri, (kuru, doygun ve doğal birim hacim ağırlıkları, içsel sürtünme açısı, kohezyonu, sıkışma yüzdesi, porozitesi, su muhtevası, atterberg limitleri ve diğer zemin karakteristikleri ile dane dağılımları.)

Zemin emniyet gerilmesi,

Afet Bölgelerinde Yapılacak Yapılar Hakkında Yönetmelik Hükümlerine göre zemin sınıfı ve grubu,

Zemin hakim periyodu,

Yatak katsayısı,

Yer altı suyunun maksimum ve minimum seviyesi,

Sıvılaşma potansiyeli,

Şev stabilitesi sorunu,

Oturma (tasman) hesaplarını ihtiva eden zemin etüt raporu hazırlanır.

(5)Bu rapor hafriyat sırasında alınacak önlemleri de (şevli kazı, iksa vb.) ihtiva etmelidir. Sondaj ve laboratuar deneyleri sonucu hazırlanan zemin etüt raporunun en az bir inşaat mühendisi tarafından imzalanması zorunludur. Hazırlanan zemin etüt raporları üniversitelerin İnşaat Mühendisliği Bölümlerinde görevli geoteknik alanında uzman öğretim üyelerince yorumlanacak ve ilave bir rapor hazırlanacaktır. Bu ilave raporda temel derinliği, temel tipi ve temel ebatları, hafriyattan çıkan zeminin dolguda kullanılıp kullanılamayacağı, zemin sınıfı, zemin emniyet gerilmesi, oturma miktarı, yer altı su seviyesi, zemin sıvılaşması olasılığı, zemin iyileştirmesi gerekip gerekmediği konularında ve zemin etüt raporunda belirtilen zemin parametreleri hakkındaki değerlendirmeleri mutlaka yer almalıdır. Zemin etüt raporu ve uzman geoteknikçi yorumu olmayan statik projeler onaylanmadan iade edilir.

TASNİF DIŞI B-7

Page 22:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(6)Zemin iyileştirilmesi önerilen yerlerde, yapılacak iyileştirme yöntemi teknik şartnamesi hazırlanarak, iyileştirmenin projedeki hedef değerleri sağlayıp sağlamadığı hususunda imalat sonrasında kullanılacak deney yöntemleri de bu şartnamede yer alır.

b. Betonarme Projeler:

(1)Betonarme ve Statik Projeler büro tescil belgesi olan bürolara yaptırılır. İstanbul Tersanesi Komutanlığı antedinde projeyi yapan, kontrol eden ve proje ihalesini üstlenen firma yetkililerinin imzaları yer alır.

(2)Statik projeler mutlaka İnşaat Mühendislerince hazırlanmalı ve yukarıda belirtilen bilgileri ihtiva eden “Zemin Etüt Raporu” ile birlikte incelenmelidir. Hesap raporunun sayfaları numaralanmalı, açılmayacak ve sayfa ilave edilmeyecek şekilde ciltlenmeli ve raporun en başına fihrist konulmalıdır.

(3)Statik hesap raporlarında hesaplar aşağıdaki sırada yer almalıdır.

(a)Binanın taşıyıcı sistemi hakkında genel teknik raporu,

(b)Düşey yüklerin analizi,

(c)Döşeme hesapları,

(d)Çerçeve çizimleri ve eleman boyutları,

(e)Yatay yüklerin bulunması, (deprem, rüzgar vb.)

(f) Kolon, perde ve kiriş hesapları,

(g)Merdivenler,

(h)Temeller,

(i) Özel elemanlar, (parapet veya prefabrik elemanlar vb.)

(j) İstinat perdeleri.

(4)Yapı taşıyıcı sisteminin düzenlenmesiyle ilgili rapor tanzim edilir. Rapor; sistem seçimini, eleman seçimini ve varsa özellik gerektiren durumlara da açıklık getirecek şekilde düzenlenir. Sistem seçiminde ekonomiklik ve emniyet ön planda tutulur. Taşıyıcı sistemin seçiminde aşağıdaki hususların yerine getirilip getirilmediği kontrol edilir.

(a)Sistemde zayıf kolon – güçlü kiriş yerine, güçlü kolon – zayıf kiriş seçilmelidir.

(b)Çerçeveli sistem yerine perdeli sistem tercih edilmelidir.

(c)Taşıyıcı sistem burulmaya imkan vermeyecek şekilde düzenlenmelidir.

(d)Ağır cephe panelleri kullanmaktan kaçınılmalıdır.

(e)Sistemde kısa kolon oluşmasına izin verilmemelidir.

(f) Zayıf kat oluşmasına olanak tanınmamalıdır.

(g)Binalar arasında binaların çarpmasına imkan vermeyecek şekilde boşluk bırakılmalıdır.

(h)Kolonların konsollara oturmasına kesinlikle izin verilmemelidir.

(5)Proje yükleri TS. 498’e uygun olarak seçilerek, yapı önem katsayısında “Afet Bölgelerinde Yapılacak Yapılar Hakkında Yönetmelik” esas alınır. Bu kaynaklarda bulunmayan değerler analiz ile bulunur. Özellik arz eden veya ağır iklim

TASNİF DIŞI B-8

Page 23:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

koşullarında inşa edilecek yapılardaki proje yükleri TS 498 standardındaki değerler, asgari değerler kabul edilerek, proje hazırlanmasından önce proje müellifine bildirilir.

(6)Tasarımı yapılan bina için “Yürürlükteki Yönetmelik” hükümlerinde tanımlanan yapı düzensizlik türleri ayrıntılı olarak irdelenerek, eğer varsa, binada hangi tür düzensizliklerin bulunduğu açık olarak belirtilir. Düzensizlikler sonucu ilave tesirler yapı hesaplarında dikkate alınır. Mümkün olduğunca Afet Bölgelerinde Yapılacak Yapılar Hakkında Yönetmelikte belirtilen düzensizliklerden kaçınılır. R Katsayısı, süneklik düzeyine (yüksek, normal, karma) bağlı olarak seçilir. Deprem yük azaltma katsayısının seçim nedeni açıkça belirtilir.

(7)Donatı hesabında TS 500 ve Deprem Yönetmeliğinin önerdiği maksimum ve minimum koşullar göz önünde bulundurulur.

(8)Yapı hangi deprem bölgesinde yer alırsa alsın, yapının toplam kat alanının % 0,25’i veya taban alanının % 1,00’ inden büyük olanı kadar her iki yönde deprem perdeleri dizayn edilir. Binanın bulunduğu deprem bölgesi, bina yüksekliği ve taşıyıcı sistem düzensizlikleri göz önüne alınarak uygulanan deprem hesap yönteminin seçiliş nedeni açık olarak belirtilir.

(9)Elle veya bilgisayarla yapılan statik hesaplar kolaylıkla izlenebilir şekilde düzenlenir. Gerektiğinde şekil, plan ve tablolarla açıklamalar yapılır. Hesapta kullanılan bilgisayar yazılımının adı, müellifi ve versiyonu hesap raporunda açık olarak belirtilir. Proje kontrol makamının talep etmesi durumunda, bilgisayar yazılımının teorik açıklama kılavuzu, lisans sözleşme sureti hesap raporuna eklenir.

(10) Temel tipinin seçiminde zemin emniyet gerilmesi ve oturma hesapları esas alınır.

(11) Taşıyıcı yapı elemanlarının dizaynında rijitlik merkezi ile geometrik merkezin çakıştırılmasına özen gösterilir. Mimari nedenlerle bu çakışmanın sağlanamadığı hallerde burulma etkisi incelenir.

(12) Proje çizimleri, projenin uygulanırlığını sağlayacak şekilde tüm bilgi, boyut ve detayları içerecek şekilde hazırlanır.

(13) Binaların depremde sağlıklı davranış gösterebilmesi için bina yüksekliğinin 1/6’sı kadar yükseklikte bodrum kat planlanması tavsiye edilir. Bodrum kat yapılmıyorsa temel derinliğinin don derinliği ve sağlam zemin kotu da dikkate alınarak tek katlı yapılarda en az 1,2 m., çok katlı yapılarda en az 1,5 m. olması sağlanır.

(14) Temel iç dolgusu, zemin klasına ve kazıdan çıkan malzemenin dolguda kullanılıp kullanılamayacağı kriterlerine göre değerlendirilir. Kaya veya batak balçık gibi kazı malzemeleri bina içi dolgularında kullanılmaz.

(15) Sadece temel altlarında 10 cm. kalınlıkta 250 doz grobeton imalatı yapılır.

(16) Klasik bina hafriyat projeleri, en dıştaki temel ucundan itibaren 50 cm. çalışma mesafesi ve temel derinliği 1,75 metreden fazla ise klasa göre şevli olarak hazırlanır.

(17) Taşıyıcı sistemde boyuna donatı olarak düz yüzeyli donatı yerine, mutlaka nervürlü donatı kullanılır.

(18) Kolon, perde ve kiriş detayları ayrı ayrı verilmeli, özellikle kolon ve perdelerin mutlaka boy kesitleri bulunmalıdır. Binadaki tüm kolon kiriş birleşim bölgeleri için geçerli standart detaylarla yetinilmesi kabul edilmemeli, perde boyuna kesitinde kritik perde yüksekliği açık olarak belirtilmelidir. Bu yükseklik boyunca ve diğer perde kesimlerinde kullanılan enine donatıların çap, sayı ve aralıkları ile açılımları çizimler üzerinde açık olarak gösterilmelidir.

TASNİF DIŞI B-9

Page 24:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(19) Pas payları zeminle temas eden elemanlarda en az 6 cm., üst yapıda kiriş, kolon ve perdelerde 3 cm., döşemelerde 2 cm. alınır.

(20) En alt katta 19 cm. ve daha kalın duvar altlarına duvar altı perdeleri (DAP) projelendirilir.

(21) Her çeşit temelde, yüklerin bileşkesi ile temel taban alanının ağırlık merkezinin imkan nispetinde üst üste getirilmesine çalışılır. Bu mümkün olmadığı takdirde negatif taban gerilmesi yok edilecek şekilde boyutlandırma yapılır.

(22) İstinat duvarlarına ihtiyaç duyulup duyulmadığı konusu zemin etüt raporundaki zeminin kayma açısı ve zemin kotları irdelenerek karara bağlanır. Sadece arazi zemin kotlarına bağlı olarak istinat perdeleri oluşturulmuşsa, anılan türdeki istinat perdelerine ihtiyaç olup olmadığı titizlikle kontrol edilir.

(23) Kolonlarda filiz ve kirişlerde bindirme ve ankraj boylarının Deprem Yönetmeliğine uygun olup olmadığı kontrol edilir.

(24) Etriye ve Çirozların Deprem Yönetmeliğine uygun yapılıp yapılmadığı kontrol edilir.

c. Çelik Konstrüksiyon Projeleri:(1)Çelik konstrüksiyon projeleri Deprem Yönetmeliği ve TS 648 standartlarına uygun

olarak hazırlanacaktır

(2)Yük analizleri; TS 498, mimari proje ve detaylarına uygun olarak yapılacaktır. Şiddetli rüzgar yükü ve normalin üzerinde kar yükü gibi özellik arz eden veya ağır iklim koşullarında, inşa edilecek yapılarda proje yükleri TS 498 standardındaki değerler asgari değerler olarak kabul edilecektir. Son 50 yılın meteorolojik raporlarına ait değer ile TS 498 ‘de belirtilen ve asgari değer olarak kabul edilen yüklerin 2 (iki) katı alınacak ve karşılaştırma yapılacaktır. Hangi değer büyükse bu değer kar yükü olarak alınacak ve projeler bu kar yüküne göre tasarlanacaktır.

(3)Aşık aralıkları kaplama cinsine uyacak, makas aralıkları ise yapı boyunu tam olarak bölecektir. Makas elemanların verimli olarak çalıştıracak şekilde aşık aralıkları dizayn edilecektir.

(4)Çelik konstrüksiyon makaslar 1/10, detaylar 1/5 ölçekli olarak çizilecektir. Seçilen profiller, elemanların kesin boyları, düğüm noktaları birleşim detayları, kaynak kalınlık ve boyları detaylarda mutlaka gösterilecektir.

(5)Çelik projelerinde her eleman için mutlaka açık ve anlaşılır olacak şekilde hesaplar yapılacaktır. Ayrıca her elemanın kaynak hesapları ayrı ,ayrı ve ayrıntılı olarak gösterilecektir. Konstrüksiyonda kullanılan tüm eklere ait (aşık ekleri dahil) hesaplar ve birleşim elemanlarının tahkikleri hesap raporunda yer alacaktır.

(6)Düşey stabilite bağlantıları, makas açıklığı 15 metreden az olanlarda mahya düzleminde, 15 – 30 metre arasında olanlarda en az iki düzlemde; 30 metreden daha büyük olanlarda ise biri mahya düzleminde olmak üzere en az üç düzlemde oluşturulacaktır.

(7)Çatı düzlemi stabilite bağlantıları ilk ve son aksta mutlaka ve aralardaki 2 ile 5 makas aralarında bir düzenlenecektir.

(8)Aşık ve makaslarda gerekli sehim tahkikleri hesaplarda ifade edilecektir.

(9)Çelik çatı ve her türlü çelik yapılarda basınç elemanlarında narinlik oranı 200’den fazla olmayacaktır

TASNİF DIŞI B-10

Page 25:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(10) Geometrisi düzgün ve açıklığı 40 metreden az olan çatılarda düzlem çelik çatı makas sistemi tercih edilecektir. Çatı formu düzensiz veya açıklığı 40 metreden fazla olan sistemlerde ise uzay kafes sistemi tercih edilebilecektir.

(11) Çelik konstrüksiyon yapıların davranışlarında seçilen mesnet tipleri çok büyük önem arz etmektedir. Kayıcı bir mesnedin sabit mesnet olarak imali durumunda sistem davranışı değişmekte, çekme çubuklarında basınç gerilmeleri oluşarak, burkulma sonucunda sistem tahrip olabilmektedir. Bu nedenle seçilen mesnet türleri titizlikle değerlendirilmeli, gerek proje safhasında ve gerekse imalat aşamasında projede öngörülen detayların aynen uygulanması sağlanarak, mesnet hesaplarına ayrı bir önem verilecektir.

d. Altyapı Projeleri:

(1)Kanallar/Galeriler

(a)Ölçekli vaziyet planı üzerinde kanalların güzergahı gösterilecektir.

(b)Kanal ve galeri kesitleri çizilecektir. Borular ve konsollar gösterilecektir.

(c)Kanal ve galeri diplerine enine ve boyuna meyil verilecektir.

(d)Sabit ve hareketli mesnetlerin yerleri belirtilecek, detayları verilecektir.

(e)Kanalda suların birikme bölgesi ve deşarjının yapıldığı yer gösterilecektir.

(f) Malzeme sokma ve havalandırma menfezlerinin yerleri belirtilecek, kesit verilecek ve ölçümlendirilecektir.

(g)Elektrik ve telefon kablolarının, kanallar içinde konsollar üstünde ve/veya tavalar içinden geçirilmesi sağlanacaktır.

(h)Kanal boyutları tip projesine uygun olarak içinde tesisata müdahale edilebilir şekilde yapılacaktır.

(i) Kanalların mevcut sistemle bağlantısı varsa, vaziyet planında mevcut ve yeni yapılacak kısımlar gösterilecektir.

(2)Toprakaltı Hatlar

Toprakaltı çekilecek hatların güzergahı vaziyet planında gösterilecek ve hatta ait döşeme kesiti detaylı olarak belirtilecek.

(a)Kritik noktalara ait(köşe dönüşleri, bina bağlantı noktaları, hatların kesişme noktaları vb.) detay verilerek gösterilecektir.

(3)Kanalizasyon Projeleri

Kanalizasyon projeleri hazırlanırken;

TASNİF DIŞI B-11

Page 26:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(a)İller Bankası şartnamelerine uyulur. Öncelikle kişi başına ortaya çıkan atık su debisi ile personel sayısı dikkate alınarak toplam atık su debisi tespit edilir. Bu sonuçlara göre hesaplar yapılarak kanalizasyon boru çapı seçimi yapılır.

(b)Hattın güzergah planı hazırlanır. Bu plan üzerinde kanalizasyon hattı güzergahı, rögar yerleri ve rögar ara mesafeleri, rögar taban ve zemin kotları, bina çıkış yerleri ve kotları ile bu bölgelere ait tabii zemin kotları gösterilir.

(c)Hattın boy profili çıkarılar bu profilde rögar numaraları, ara mesafeleri, boru taban kotları, eğimler ve boru çapları gösterilir. Ayrıca boy profili üzerinde kazı derinlikleri belirtilir.

(d)Kanalizasyon hattı eğimleri İller Bankası şartnamelerindeki eğim sınırlarını aşmamalıdır. Aşma durumu söz konusu olduğu takdirde şüt (Düşüm bacaları) yapılır. Şüt yüksekliği 2 metreyi geçmemelidir.

(e)Muayene bacaları arasındaki mesafe hattın düz olarak geçtiği yerlerde en fazla 60 metre alınır.

(f) Kanalizasyon hatlarında maksimum hız 3 metre/sn, minimum hız 0,5 metre/sn olarak alınır.

(g)Kanalizasyon hattının kazı hacimlerini gösterecek tarzda tip kesiti hazırlanır.

(h)Hendek taban genişlikleri d+2x20 cm. olarak alınır. (d=boru çapı)

(i) Hendek taban genişlikleri, derinliği 1,5 metreden daha az hendeklerde 0,60 metre ve 1,5 metreden daha derin hendeklerde 0,80 metre alınır.

(j) Kanalizasyon hatlarının 10 santimetre kalınlıkta yataklanma dolgusu ile beraber boru üstünden 30 santimetre yukarıya kadar kısmı kum ile doldurulur. Hendeğin geri kalan kısmı hafriyattan çıkan malzeme ile doldurulur.

(k)Projeler hazırlanırken hesap raporunun başına hesap esaslarını özetleyen teknik bir rapor konulur.

(l) Kanalizasyon hattı mümkün olduğu kadar kısa tutularak en ekonomik güzergah seçilir.

3. Elektrik Tesisatı Projelerin Hazırlanma Esasları

a. Genel Hususlar:

Projeler, tescilli bürolar tarafından aşağıdaki dokümanlar esas alınmak suretiyle düzenlenir.

Bayındırlık ve İskan Bakanlığı Elektrik Mühendisliği Proje Düzenleme Esasları.

İller Bankası ve TEDAŞ tarafından yayımlanan Proje Rehberleri ve Tip Projeler.

Bayındırlık ve İskan Bakanlığı Yapı İşleri Elektrik Tesisatı Genel Teknik Şartnamesi.

Elektrik İç Tesisleri Yönetmeliği.

Elektrik Mühendisleri Odası tarafından yayımlanan ilgili Yönetmelikler.TASNİF DIŞI B-12

Page 27:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

Sanayi ve Ticaret Bakanlığı ile Enerji ve Tabii Kaynaklar Bakanlığı tarafından yayımlanan ilgili Yönetmelikler.

Türk Standartları Enstitüsü tarafından yayımlanan veya Uluslararası geçerliliği olan ilgili standartlar.

Millî Savunma Bakanlığı tarafından yayımlanan prensip emirleri, projelendirme standartları ve Tip Elektrik Tesisat Projeleri.

Elektrik Kuvvetli Akım Tesisleri Yönetmeliği.

Binaların Yangından Korunması Hakkında Yönetmelik.

Elektrik Tesislerinde Topraklamalar Yönetmeliği.

Asansör Yönetmeliği.

Elektrik Dağıtım Tesisleri Genel Teknik Şartnamesi.

Türk Silahlı Kuvvetlerince yayımlanan Yönergeler veya uyulması talep edilen Askeri Kriterler.

b. Elektrik Tesisatı Projeleri Hazırlık Safhaları:

Elektrik tesisatı ile ilgili her türlü imalat, uygulama projelerine göre yaptırılır. Uygulama projeleri aşağıda belirtilen safhalar gerçekleştirilerek hazırlanacaktır:

(1)Öneri Raporu Safhası: İnşa edilecek yapıya ait mimari, statik ve makine projelerinin elektrik tesisat projelerini etkileyecek özellikleri bu raporda açıklanır. Tesis edilecek yapının yerini ve civardaki diğer yapı ile tesisleri gösteren ölçekli vaziyet planı raporla birlikte verilir. Raporda; inşa edilecek yapının kullanım amacı, elektrik enerjisinin nasıl temin edileceği, telefon santraline ihtiyaç olup olmadığı, planlanan yangın ihbar sisteminin özellikleri, aydınlatma hesaplarında esas alınacak en az aydınlık düzeyleri, kışla bölgesinde mevcut bir itfaiye merkezi, enerji merkezi veya telefon santrali olup olmadığı ve kapasiteleri/özellikleri, dış yıldırımlık tesisatı için koruma düzeyinin seçim hesabı yer alır. Yapıda asansör kullanılması gerekiyorsa “Asansör Avan Projesi ve Hesapları” bu rapora eklenir. Ayrıca raporla beraber “Elektrik Tesisat Projesi İhtiyaç ve Koordinasyon Formu” tanzim edilerek ilgili Kullanıcı Birlik Komutanlığı, MSB. İnşaat Emlak Bölge Başkanlığı ve Proje Müellifi Firma yetkilileri tarafından imzalanır.

(2)1/100 Ölçekli Kesin Proje Safhası: 1/100 Ölçekli Mimari Projenin onayını müteakip elektrik tesisat projelerinin hazırlanması için gerekli bilgiler (Her mahal için talep edilen telefon prizi, tv prizi, network uç sayısı, data dağıtım kabinetlerinin yeri, kullanılacak network altyapı elemanlarının özellikleri, binanın jeneratörden beslenmesine gerek olup olmadığı, tesisatın TEMPEST kriterlerine uygun olarak yapılıp yapılmayacağı, aşırı güç veya değişik frekansla çalışan cihazların olup olmadığı, yapılması istenen güvenlik sistemlerinin özellikleri ve diğer talepler) İstanbul Tersanesi Komutanlığından alınır. 1/100 ölçekli proje üzerinde, kablo bağlantıları hariç diğer tüm elektrik tesisat elemanları alınan bu bilgiler doğrultusunda yerleştirilerek, TEMPEST kriterlerinin uygulanacağı mahaller gibi özellik arz eden yerlerde tesisatın nasıl yapılacağı hazırlanacak raporla izah edilir. Hazırlanacak 1/100 ölçekli elektrik tesisat projesi ve rapor, koordine maksadıyla ilgili Kullanıcı Müdürlüğe verilir. Ayrıca kesinleşen enerji ihtiyacı doğrultusunda ilgili TEDAŞ Müessese Müdürlüğüne enerji müsaadesi alınması maksadıyla İstanbul Tersanesi Komutanlığı tarafından gerekli müracaatlar yapılır. Alınacak enerji müsaadesi doğrultusunda proje müellifi firma, enerji getirme projelerini hazırlayarak İstanbul Tersanesi Komutanlığının uygun görüşünü müteakip, TEDAŞ Müessese

TASNİF DIŞI B-13

Page 28:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

Müdürlüğüne onaylatır. TELEKOM’a devredilecek telefon altyapısı ile ilgili projeler ilgili TELEKOM Md.lüğü ile koordine edilir.

(3)1/50 Ölçekli Uygulama Projesi Safhası (3 Tk.) :Tüm koordine işlemlerinin tamamlandığı ve kesin olarak ihtiyaçların belirlendiği 1/100 ölçekli proje safhasını müteakip, tesisteki sistemlere ait kablo bağlantılarını, sahaya ait zayıf ve kuvvetli akım dağıtımını, çevre tanzim projesine uygun yol ve emniyet aydınlatmalarını, yıldırımdan korunma tesisatını, temel topraklamasını gösteren projeler ile ihale kapsamında yapılmasına ihtiyaç duyulan diğer projeler bu safhada proje müellifi firma tarafından eksiksiz olarak idareye teslim edilir. Yapılması planlanan yapı ile mevcut tesisler arasında tesis edileceği belirtilen kablolara ait mesafeleri gösteren paftalar proje müellifi firma tarafından İstanbul Tersanesi Komutanlığına onaylatılır. Bu safhada, her paftada kullanılacak malzemeler ile ilgili tarifler verilerek, pano ve tablolar için detay proje hazırlanarak, ana pano odası, data dağıtım kabinetlerinin yerleşeceği odalar, TEMPEST kriterlerinin uygulanacağı mahaller gibi yerler için asma tavan, yükseltilmiş döşeme vs. özelliklerin de gösterildiği 1/20 ölçekli detay projeler hazırlanır. Projelerde inşaat kapsamında tedarik edilmeyecek olan cihazlar/sistemler kesikli çizgi ile gösterilerek bu cihazların İstanbul Tersanesi Komutanlığı tarafından tedarik edileceği özellikle belirtilir.

(4)Elektrik Metraj, Keşif ve Yaklaşık Maliyet Safhası:

İnşaatın uygulama projelerinin 1/50 uygulama safhası oluşturulurken keşif hazırlık çalışmaları başlatılır. 4734 Sayılı Kamu İhale Kanunu uyarınca yapı yaklaşık maliyetinin gizli tutulması esastır. İşlerin büyük bir bölümünün anahtar teslimi ile yaptırılacağı göz önüne alındığında yapı yaklaşık maliyetinin gerçekçi olarak tespiti önem arz etmektedir. Bu amaçla;

(a)Onaylı uygulama projelerine göre kesin metrajlar ve buna bağlı olarak keşifler hazırlanır.

(b)Her bir imalat kaleminin teknik şartnamesi ayrıntılı olarak hazırlanır ve keşif ekine konulur.

(c) İmalat kalemlerine ait teknik şartnamelerde firma marka ve modelini tarif eden ifadelere kesinlikle yer verilmez.

(d)İnşaat, makine ve elektrik imalatlarının birbirleri ile ilgili veya girişim yapma ihtimali olan imalat kalemlerinin keşif miktar ve fiyat tarifleri, ilgili mühendislerce koordineli olarak hazırlanır. Keşifler her bir yapı ve alt yapı ünitesi için ayrı ayrı yapılıp, sonuçlar genel icmal sayfasında birleştirilir.

(e)Metrajlar, fiyat tarifleri ve keşif özetleri, uygulama projeleri ve mahal listelerine bire bir uyumlu olarak hazırlanır.

(f) Keşiflerde yer alan fiyatlar günün rayiç değerlerine göre belirlenir.

(g)Ağırlık olarak ödenmesi tarif edilen imalat kalemlerinin ağırlık metraj tahkikleri hassasiyetle yapılarak metrajlara aksettirilir.

(h)Metraj ve keşif hazırlık çalışmaları gizlilik ilkelerine riayet edilerek yürütülür.

TASNİF DIŞI B-14

Page 29:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

c. Elektrik Tesisat Projelerinin Hazırlanması ve İmalat İle İlgili Dikkat Edilecek Hususlar:

(1)Genel Hususlar:

(xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx)Uygulama projeleri bilgisayar destekli çizim programları kullanılarak 1/50 ölçekli

olarak, detay projeleri ise 1/20, 1/10 veya 1/5 ölçekli olarak çizilir. Proje üzerine notlar “Arial 8, 10 veya 12“ karakteri ile yazılır.

(yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy)Pafta numaraları ”E-01/Toplam Pafta Sayısı” şeklinde verilerek, E-01 no.lu paftada

sembol cetveli, pafta listesi, tesisin vaziyet planı ve projenin genelini ilgilendiren notlar yer alır.

(zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz)Projeler asgari askeri ihtiyaçlar karşılanacak şekilde tasarlanır. Lüks ve ithal

malzeme kullanımından kaçınılarak, işletme ve idamesi kolay sistemler tercih edilir.

(aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa)Projeler imalat ile ilgili tereddüt yaratmayacak şekilde detaylı olarak hazırlanarak,

gerektiğinde yapılacak imalat proje üzerine yazılacak notlar ile de uygulayıcıya tarif edilir.

(bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb)Elektrik tesisat projelerinde, mimari projede belirtilen aks numaraları, mahal

numaraları, mahal isimleri, dilatasyon noktaları eksiksiz olarak gösterilir.

(cccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccccc)Elektrik tesisat projelerinde Elektrik Mühendisleri Odası veya Milli Savunma

Bakanlığı tarafından belirlenen semboller kullanılır.

(dddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddddd)Elektrik sistemlerinin işletilmesini açıklayan veya kazaları önlemek maksadıyla tesis

edilecek olan tüm uyarı işaretlerinin yerleri, yapıları ve muhteviyatları projelerde belirtilir, detayları verilir.

(eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee)Projelerden İlgili kuruluşa (AYEDAŞ, Türk Telekom, PTT, İSKİ vb.) onaylatılması

gerekli olanlar yüklenici tarafından onaylatılır.

(ffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffffff)Elektrik tesisat projelerinde projeyi hazırlayan mühendise ait SMM (Serbest Müşavir

Mühendis) Belgesi proje ekinde yer alır.

(2)Kuvvetli Akım Tesisatı:

(rrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrr)Binadaki bütün karakteristik mahaller için aydınlatma hesapları yapılarak bir çizelge

halinde projeye dahil edilir.

TASNİF DIŞI B-15

Page 30:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(ssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssssss)Kullanılan özel armatür tipleri için detay resimleri verilerek, özellikleri tarif edilir.

(tttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttt)Isı merkezi ve soğutma sistemlerinde kullanılan mekanik ekipman için otomatik

kumanda şemaları hazırlanır.

(uuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuu)Pano ve tablolardaki ekipmanların yerleşimi hazırlanacak detay projelerinde

gösterilir.

(vvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvvv)Ana pano odasının yapısı, elektrik kablo şaftının ölçüleri, yükseltilmiş döşeme, asma

tavan, kedi yolu gibi mimari projeyi etkileyecek ihtiyaçlar mimari projenin hazırlanması safhasında dikkate alınarak, ihtiyaçlar elektrik mühendisi ile koordine edilir.

(wwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww)“Enerji Tarifeleri Yönetmeliği”nde belirtilen tüm tesisler için kompanzasyon sistemi

yaptırılarak, buna dair proje ve hesaplar verilir.

(xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx)Restorasyon projelerinde önce röleve ve demontaj projesi hazırlanarak, demontaj ve

montaj edilecek malzemelerin listesi ayrı ayrı verilir.

(yyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyyy)Tüm yapılarda “Binaların Yangından Korunması Hakkında Yönetmelik” hükümleri

eksiksiz uygulanarak, yönetmeliğin zorunluluk getirdiği yerlerde acil aydınlatma ve yönlendirme armatürleri tesis edilerek yangın anında zehirli gaz çıkarmayan kablolar kullanılır.

(zzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzz)Telefon, Şebeke, Kesintisiz Güç Kaynağı, Bilgi İşlem vb. prizlere ait yerleşimler ile

birlikte mimari tefriş planı üzerinde gösterilen objeler (masa, dolap, etajer vb.) de gösterilecek şekilde projeler tanzim edilir.

(3)Zayıf Akım Tesisatı:

(a)İnşaat ihaleleri kapsamından çıkarılarak İstanbul Tersanesi Komutanlığı tarafından tedarik edilmesi uygun görülen malzemelere ait altyapı ihtiyaçları Kullanıcı Müdürlük ile koordine edilerek, bu malzemelerin yerleşimleri ve özellikleri projelerde kesikli çizgi ile gösterilir.

(b)Tüm yapılar için, “Binaların Yangından Korunması Hakkında Yönetmelik” hükümlerine uygun tipte yangın algılama ve uyarı sistemi projelendirilir.

(c)TV dağıtım sistemi projeleri ile birlikte sinyal kayıplarını gösteren hesaplar verilir.

(4)Asansör Tesisatı:

(a)Asansörlerin projelendirilmesi ve tesis faaliyetleri “Asansör Yönetmeliği” ne uygun olarak yaptırılır.

(b)Tüm asansörler emniyet ile ilgili hususlar açısından TS 10922‟ye ve yürürlükteki

diğer ilgili Türk Standartlarına uygun olarak projelendirilir ve tesis edilir. TASNİF DIŞI B-16

Page 31:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(c)Asansörler için, Belediye sınırları içinde ilgili Belediyeden, Belediye hudutları dışındaki yapılar için Valiliklerden işletme ruhsatı alınır.

(d)Yapımı tamamlanan asansörler için TSE‟den uygunluk raporu alınır.

(e)Asansörün yapısını ilgilendiren mukavemet (makine dairesine, kuyu dibine, ray tespit yerlerine, gelecek yüklerin miktarı ve cinsini gösteren) hesapları, asansörün imalatını ilgilendiren mukavemet hesapları ve asansöre ait mekanik hesaplar Makine Mühendisleri tarafından kontrol edilir.

(f) Yapıda asansör kullanılmasının gerekip gerekmediği Mimari Projenin 1/200 Proje Raporunda belirtilerek, söz konusu rapor ekinde “Asansör Avan Projesi ve Hesapları” yer alır. Bu aşamada asansör trafik hesabı, asansör kuvvet hesapları, asansör motor gücü hesabı, asansör kuyu tabanı ve raylara gelen kuvvetler, kuyu ve makine dairesi kesitleri hazırlanır.

(g)Asansör ile ilgili tüm yapısal ve teknik özellikler ( frekans kontrollü olup olmayacağı, toplamalı kumanda donanımı, grup kumanda donanımı, kabin içerisinin paslanmaz çelik ile kaplanması, ışın perdesi, acil kurtarma güç tertibatı vs.) projede detaylı olarak yer alır.

(h)Asansör kuyusu duvarları betonarme perde duvar olacak şekilde projelendirilir.

(i) Makine dairesiz veya hidrolik asansör zorunlu kalınmadıkça yaptırılmaz.

(5)Yedek Elektrojen Grupları ve Kesintisiz Güç Kaynakları:

(a)Yaptırılan tesisin büyüklüğüne, önem derecesine ve ihtiyaç durumuna göre yedek diesel-elektrojen grubu sistemine ait kapasite ve alt yapı projeleri hazırlanır.

(b)Birden fazla jeneratörün kullanıldığı tesislerde jeneratörler, otomatik olarak devreye girecek ve tesisin önemine göre tercihen birbirleriyle paralel olarak çalışabilecek şekilde projelendirilerek, sistemin çalışması ile ilgili detaylar (Yük alma ve yük atmada öncelik sırası, sistemin çalışma senaryosu vs.) açıklanır.

(c)Kesintisiz enerji istenen bilgisayar merkezleri, ameliyathaneler, muhabere sistemleri vb. yerlerde kesintisiz güç kaynağı sistemine ait kapasite ve altyapı projeleri hazırlanır.

(d)Jeneratörün tesis edileceği mahal için yerleşim detayları (jeneratörün kaidesi, egzost bacasının bağlantısı, temiz hava panjurunun boyutları, yakıt tankının yeri ve ölçüleri, kablo kanallarının yapısı, panoların yerleşimi vs.) 1/20, 1/10 veya 1/5 ölçekli olarak verilir. Ayrıca mahal içerisindeki cihazların yerleşimleri ve yüksekliklerini gösteren kesit ve görünüşler de projeye eklenir.

(6)Yıldırımdan Korunma ve Topraklama Tesisatı:

(a)Yıldırımdan korunma tesisatı, toprak özgül direnci ilgili kuruluş veya yetkili mühendis tarafından yerinde ölçülerek tesisin TS EN 62305-1, TS EN 62305-2, TS EN 62305-3, TS EN 62305-4 standartlarına göre yapılan Yıldırımdan Korunma Risk Analizi sonuçlarına göre projelendirilecektir. EN 62305-1, TS EN 62305-2, TS EN 62305-3, TS EN 62305-4 Türk Standartları, konuyla ilgili IEC Standartları ve Yapı İşleri Elektrik Tesisatı Genel Teknik Şartnamesinin ilgili bölümlerinde belirtilen hesaplar dahilinde projelendirilir. Yeni yapılacak tüm binalarda “Faraday Kafesli Yıldırımdan Korunma Tesisatı” projelendirilir.

TASNİF DIŞI B-17

Page 32:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

Projelerde çatı üzerindeki tüm yükseklikler ölçüleri verilmek suretiyle belirtilerek, tasarım; onaylı çatı planı projesine göre yapılacak, iniş iletkenlerinin yapılış şekli ile ilgili cepheden görünüş resimleri, test klemensi detayı ve topraklama çubuklarına ait menhol detayı verilir. Termokaynak (Cadweld) eki yapılan noktalar proje üzerinde özel bir sembol ile işaretlenerek belirtilir.

(b) Radyoaktif ve aktif paratoner sistemi kullanılamaz.

(c)Tüm yeni yapılarda temel topraklaması yapılır. Projelerdeki hesaplar ve uygulamalar "Elektrik Tesislerinde Topraklamalar Yönetmeliği”ne uygun olacak şekilde yapılarak, iletkenlerin döşenme biçimi, ek noktalarındaki uygulamalar, bağlantı filizlerinin yerleri, dilatasyon noktasındaki geçişler, temel donatısı ile yapılacak irtibatlar için 1/20, 1/10 veya 1/5 detay projeler verilir.

(7)Elektrik Altyapı Projeleri:

(a)Altyapı projeleri, Garnizon Ana Yerleşim (Master) Planları göz önüne alınarak, ihtiyaçların bir merkezden karşılanacağı tarzda tasarım yapılır.

(b)Sahaya ait kablolama altyapı projelerinde mesafeler, yerinde yapılacak ölçümler ile tespit edilir. Bu konudaki projelerin uygunluğu İstanbul Tersanesi Komutanlığı tarafından kontrol edilir. Kabloların geçirilmesi planlanan güzergah üzerindeki mevcut altyapı tesisleri (Yollar, beton kaplı sahalar, doğal gaz hatları ve elektrik kabloları, ısı kanalları vs.) vaziyet planları üzerinde gösterilerek bu tesisler ile ilgili yapılması gereken demontaj/montaj işleri detaylı olarak tarif edilir.

(c)Isı kanalı bulunan yerlerde kablolar kuvvetli ve zayıf akım olarak ayrı ayrı galvanizli tavalarla ısı kanalı içerisinden geçirilir. Galvanizli tavalar uygun şekilde topraklanır, ısı kanalı içerisi aydınlatılır ve belirli aralıklar ile priz kutuları (monofaze+trifaze) tesis edilir. Isı kanalındaki kablo kanallarının ve kabloların yerleşimi kanal kesiti üzerinde gösterilecek şekilde projelendirilir.

(d)Kabloların doğrudan toprağa gömülmesi durumunda kanallar “Elektrik Dağıtım Tesisleri Genel Teknik Şartnamesi” ve “Elektrik Kuvvetli Akım Tesisleri Yönetmeliği” hükümlerine uygun olarak projelendirilir.

(e)Onaylı çevre tanzim projesine uygun olarak çevre aydınlatma projesi hazırlanır. Projelerde ölçekli direk detayı verilerek, ağırlık analizi yapılır. Sahada mevcut direkler varsa proje üzerinde yerleri ve tipleri gösterilir. Topraklama iletkenlerinin kesitleri, topraklama çubuklarının yerleri, gerilim düşümü ve ısınma tahkiki hesapları yapılır.

(f)Yer altı kablolarına (zayıf akım ve kuvvetli akım) ait kablo kanal kesitleri, menhol yerleri, ek noktaları ve kablo güzergahını işaretlemek için kullanılan levha yerleri vaziyet planı üzerinde gösterilir.

(g)Enerji getirme projelerinde enerji nakil hattının profili verilerek, yol, vadi, dere yatağı, petrol boru hattı ve güzergah üzerindeki mevcut yapılar gösterilir.

d. İnşaat Kapsamında Yapılması Talep Edilebilecek Elektrik Tesisat Projeleri ListesiTASNİF DIŞI B-18

Page 33:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(1)Aydınlatma Tesisatı Projeleri

Bina İçi Aydınlatma Tesisatı Projesi

Çevre Aydınlatma Tesisatı Projesi

Acil Aydınlatma ve Yönlendirme Armatürleri Yerleşim Projesi

Priz Tesisatı Projesi

Kesintisiz Güç Kaynağı Priz Tesisat Projesi

Mekanik Ekipman Enerji Besleme Projesi

Mekanik Ekipman Otomatik Kontrol Projesi

Ameliyathane / Tıbbi Cihazlar Kuvvet Projesi

Enerji Getirme Projesi

Temel Topraklama Projesi

Bina İçi/ Bina Dışı Kablo Kanalları Projesi

Elektrik Pano/Tablo Detayları Projesi

(2)Zayıf Akım Tesisatı Projeleri

Yapısal Kablolama (Network Altyapı) Projesi

Merkezi Saat Tesisatı Projesi

TV/Radyo Dağıtım Altyapı Projesi

Hemşire Çağrı Sistemi Projesi

Yangın Algılama ve İhbar Sistemi Projesi

Müzik/Anons ve Ses Sistemleri Projesi

Bina İçi Telefon Sistemi Projesi

Bina Dışı Telefon Dağıtımı Altyapı Projesi

(3)Güvenlik Sistemleri Projeleri

CCTV Sistemi Projesi

Kontrollü Giriş Sistemleri Projesi

Hırsız ve İllegal Geçişlere Karşı Güvenlik Sistemleri Projesi

(4) Enerji Altyapısı ve Diğer Projeler

TASNİF DIŞI B-19

Page 34:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

Trafo/Jeneratör ve Enerji Getirme Projesi

Saha Alçak Gerilim Dağıtım Projesi

Arıza Uyarı ve Yük Yönetim Sistemleri Projesi

Temel Topraklama Projesi

Yıldırımdan Korunma Tesisatı Projesi

Potansiyel Dengeleme Sistemi Projesi

Asansör Sistemleri Projesi

Bina İçi/ Bina Dışı Kablo Kanalları Projesi

Statik/Dinamik Konvertör Beslemeleri Altyapı Projesi

Elektrik Pano/Tablo Detayları Projesi

TEMPEST Uygulama Projesi

4. Mekanik Projelerin Hazırlanma Esasları

a. Makine Tesisatı Projelerini Hazırlama Esasları

Genel Esaslar

(1)Makine Tesisat Projelerinde yer alacak dokümanlar aşağıda sıralanmıştır:

(a)Sıhhi Tesisat,

Temiz su tesisatı

Pis su tesisatı

Kullanma sıcak su tesisatı

Su deposu ve hidrofor tesisatı

Bahçe sulama tesisatı

(b)Isıtma Tesisatı,

Kalorifer tesisatı

Brülör tesisatı

Uzaktan ısıtma tesisatı

Yer üstü ve yer altı yakıt tankı tesisatı

(c) Isı Yalıtımı,

TASNİF DIŞI B-20

Page 35:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

Özgül ısı kaybı hesabı

Yıllık ısıtma enerjisi hesabı

Yoğuşma tablosu

Isı iletim katsayıları hesabı

Isı kaybı hesabı

Radyatör hesabı

Boru direnç hesabı

(d)Otomatik Kontrol tesisatı

(e)Soğutma tesisatı

(f) Havalandırma tesisatı

(g)Klima tesisatı

(h)Doğal Gaz tesisatı

(i) LPG tesisatı

(j) Basınçlı Hava tesisatı

(k)Mutfak tesisatı

(l) Çamaşırhane tesisatı

(m) Arıtma tesisatı

(n)Havuz tesisatı

(o)Kızgın Sulu, Kızgın Yağlı Isıtma Sistemleri

(p)Buharlı Isıtma Sistemleri

(q)Medikal Gaz tesisatı

(r) Yangın tesisatı

(2)İdarenin ihtiyaç duyduğu bina tesisatı ile ilgili olup açıkça yaptırılacağı belirtilmemiş Etüt ve Proje işleri de, bu hizmetlerin kapsamında kabul edilecektir.

(3)Makine tesisatı projeleri, Makine Mühendisleri Odasından(TMMOB) alınmış olan, “Serbest Müşavirlik Mühendislik Bürosu Tescil Belgesi” ve/veya “Mekanik Tesisat Uzman Mühendis Belgesi” belgesine sahip firmalar veya kişiler tarafından yapılacaktır. Firmaların sahip olduğu belgeler, projelerin yapıldığı yılda alınmış olacak ve yapılacak tesisatlar büroların uzmanlık/yetki sınıfı kapsamında olacaktır.

(4)Projeler, aşağıdaki dokümanların en son yayımlanmış nüshaları esas alınmak suretiyle düzenlenecektir:

Çevre ve Şehircilik Bakanlığı Makine Mühendisliği Proje Düzenleme Esasları,

Yapı İşleri Makine Tesisatı Genel Teknik Şartnamesi,

TASNİF DIŞI B-21

Page 36:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

İller Bankası tarafından yayımlanan “Proje Rehberleri ve Tip Projeler”,

Makine Mühendisleri Odası tarafından yayımlanan ilgili Yönetmelikler,

Türk Standartları Enstitüsü(TSE) tarafından yayımlanan veya uluslararası geçerliliği olan standartlar,

Millî Savunma Bakanlığı tarafından yayımlanan Muhtıra, Yönetmelik, Konsept, Prensip Emirleri, Projelendirme Standartları ve Tip Makine Tesisat Proje ve Tip Detayları,

Binaların Yangından Korunması Hakkında Yönetmelik,

Türk Silahlı Kuvvetlerince yayımlanan Yönergeler veya uyulması talep edilen Askeri Kriterler,

DIN, NFPA, VDI, ISO, ASHRAE normları ve yayınları,

Türk Tesisat Mühendisleri Derneği yayınları,

Tesisat Projeleri Tip Detay Albümü,

Makine Tesisatı konusunda hazırlanmış ilgili yayınlar,

(5)Projeler özelliklerine göre aşağıdaki kurum ve kuruluşlar ile koordineli olarak hazırlanacaktır:

(a)Doğal gaz dağıtım alt yapısı olan yerlerde EGO, İGDAŞ gibi inşaatın yapılacağı ildeki gaz kuruluşları ile koordine edilerek Doğal gaz projeleri hazırlanır.

(b)İçme suyu ve kanalizasyon hattı, bağlı olduğu kuruluşlar ile koordineli olarak hazırlanır.

Teknik Esaslar

(1)Pafta ölçüleri pafta boyu=20cmxpafta eni=25cm ve katları olarak oluşturulacaktır. Yaprak halinde proje düzenlenmeyecek ve projeler ciltlenmeyecektir.

(2)Planlar her paftada aynı bakış yönünde yerleştirilecektir. Seçilen koordinat sistemi mimari, statik ve tesisat projelerinde aynen ve aynı yönde kullanılacaktır.

(3)Plan paftalarında mimari ve gerekli statik elemanlar ince çizgilerle anlaşılır bir şekilde çizilecektir. Tesisat yönünden gereksiz çizgilere ve ölçülere yer verilmeyecektir.

(4)Pafta üzerindeki tesisat elemanları TS 2164, TS 1258 ve ilgili diğer standartlara uygun sembol ve çizgiler kullanılarak yapılacaktır.

(5)Pafta üzerindeki notlar ARIAL 8, 10, 12 font ve büyük harf olacaktır.

(6)Rapor ve hesaplar 210x297mm ölçekli sayfalara bilgisayar destekli olarak “Ofis programları” kullanılarak ARİAL-12 fontla yazılacak raporun “içindekiler” bölümü olacak ve sayfalar numaralandırılacaktır. Raporun ön ve arka yüzü beyaz karton ve asetat kullanılarak ciltlenecektir. Spiral cilt kullanılmayacaktır. Raporun hesaplar

TASNİF DIŞI B-22

Page 37:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

kısmında; Sıhhi Tesisat, Kalorifer Tesisatı, Doğalgaz Tesisatı vb. gibi tesisat bölümlerine ait cihaz ve müştemilat hesapları ilgili yayınlarda belirtildiği gibi yapılacaktır. Hesaplarla ilgili kabuller ve bu kabullere ait sabitler belirtilecektir. Raporun giriş kısmında ilgili tesisatın ne şekilde kurgulandığı, ana tesisat gruplarının neler olduğu, neden ihtiyaç duyulduğu, niçin bu çözümün seçildiği gibi hikayesi ana hatları ile özetlenecektir.

(7)Plan, kolon şeması ve hesaplar arasında detaylandırılacak tesisat elemanları ve bölümlerine tip ve sayılarına göre harf ve numaralar verilecek, bu numara ve harfler projenin her safhasında aynen kullanılacaktır.

(8)Her paftanın 20x25cm ölçüsündeki sağ alt köşesi pafta katlandığında en üstte kalacaktır. Bu kısımda projenin idare tarafından hazırlanmış örneği olan tanıtım ve onay bilgilerini içeren bölümü olacaktır. Standart tek yaprak ölçüsü 25x20 cm=0.05m2’dir. Proje büyüklüğüne göre; A grubunda, pafta eni sabit tutularak boyu 20’şer cm olarak (1x25=25, sabit, 1x20=20, 2x20=40, vb. 0.05, 0.10, 0.15, 0.20, 0.25 m2 vb.), B grubunda, ( 2x25=50 sabit, 3x20=60, 4x20=80, vb. 0,30, 0.40 m2), C grubunda, (3x25=75 sabit, 5x20=100, 6x20=120, vb. 0.75, 0.90 m2), D grubunda, (4x25=100 sabit, 6x20=120, 7x20=140 vb. 1.20, 1.40 m2) olarak arttırılacaktır.

(9) Çizim, kısaltma, işaretleme vb. hususlarda ilgili TS’larına uyulacaktır. Belirlenmemiş hususlarda izlenecek yol ve yöntem öneri raporunda belirtilecek ve idarenin onayını müteakip kullanılacaktır.

(10) Bütün projelerde küçük bir ölçekte yapının plan ve kesiti şablon olarak çizilecek ve bunun üzerine paftanın ait olduğu kat, kesit yeri veya görünüş belirtilecektir.

(11) Ölçü, işaretleme ve hesaplamalarda, standartlarda veya teknik şartnamelerde kabul edilmiş olanlar hariç olmak üzere metrik sisteme uyulacaktır.

(12) Hesaplama ve projelendirmede; öncelik sırasına göre yasalara, tüzüklere, yönetmeliklere, mecburi TS’larına, Genel Teknik Şartnameye, birim fiyat tariflerine ve yürürlükteki diğer standart ve yayınlara uyulacaktır.

(13) Belirlenmemiş hususlarda izlenilecek tutum ve yararlanılacak literatür öneri raporunda belirtilerek, idarenin onayı alınacaktır. İdare önerilecek veri ve hesap usullerinin kabul edilebilecek bir literatür ve standartla belgelenmesini veya özel bir çalışmayla saptanmasını isteyebilecektir.

(14) Uygulama projeleri bilgisayar destekli çizim programları kullanılarak 1/50 ölçekli olarak, detay projeleri ise 1/20, 1/10 veya 1/5 ölçekli olarak çizilecektir.

(15) Pafta numaraları “T-01/Toplam Pafta Sayısı” şeklinde verilecek, T-01 numaralı paftada sembol cetveli, pafta listesi, tesisin vaziyet planı ve projenin genelini ilgilendiren notlar yer alacaktır.

(16) Projeler asgari askeri ihtiyaçları karşılayacak şekilde tasarlanacak, lüks ve ithal malzeme kullanımından kaçınılarak, işletme ve idamesi kolay sistemler seçilecektir.

(17) Projeler imalat esnasında tereddüt yaratmayacak şekilde detaylı olarak hazırlanacak, gerektiğinde yapılacak imalat proje üzerine yazılacak notlar ile de tanımlanacaktır.

TASNİF DIŞI B-23

Page 38:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(18) Projelerde mimari projede belirtilen aks numaraları, mahal numaraları, mahal isimleri ve dilatasyon noktaları eksiksiz ve aynen gösterilecektir.

(19) Projelerde yapılması önerilen sistemler ile ilgili (kazan, boyler, eşanjör, vb.) en az iki imalatçı firma kataloğu, 1/100 kesin proje safhasında proje ile birlikte verilecek ve teklif edilen ürün katalog üzerinde işaretlenecektir.

(20) Tesisat kapsamında kullanılacak tüm cihazlar en son numaralı paftada cihaz listesi yapılarak belirtilecektir. Bu listede cihazın tanımı, kapasitesi, adedi ve birim fiyat numarası yer alacaktır. Cihaz listesi tüm projede tek bir paftada yer alacaktır.

(21) Makine tesisatı imalatlarından firma seçimi yapılacak ve imalat projesi hazırlanacak cihaz ve tesisatlar (mutfak-çamaşırhane tesisatı, medikal gaz tesisatı, yangın tesisatı vb.) belirtilecektir.

(22) Makine tesisatı proje hizmetlerinde 1/100 ve 1/50 safhalarda tüm tesisat çeşitlerinde aşağıdaki projeler yer alacaktır;

(a)Hesap raporu

(b)Vaziyet Planı

(c)Plan

(d)Kolon Şeması

(e)İzometrik Şema

(f) Akış Şeması

(g)Detay Resimleri

b. Proje Düzenleme Hizmetleri Esasları

(1)Öneri Raporu (Avan Proje Safhasında Safhası)

(a)Öneri raporu; muhtelif çözüm şekillerini ve tesisat çeşitlerini, işletme amortisman masrafları nazara alınarak, yapılacak mukayese ve rantabilite hesaplarına dayanan ekonomik ve teknik etütlerinin, tesislerin prensip ve sistemleri üzerindeki önerileri, kroki, şema ve hesaplarla belirten rapor şeklinde olacaktır.

(b)İnşa edilecek yapıya ait mimari ve statik projelerinin makine tesisat projelerini etkileyecek özellikleri bu raporda açıklanacaktır.

(c)Tesis edilecek yapının yerini ve civardaki diğer yapı ile tesisleri gösteren ölçekli vaziyet planı raporla birlikte verilecektir.

(d)Raporda; inşa edilecek yapının kullanım amacı, kullanma temiz suyunun nasıl temin edileceği, pis suyun nereye bağlanacağı, kazan dairesine ihtiyaç olup olmadığı, planlanan yangın söndürme sisteminin özellikleri, kullanma soğuk-sıcak su ısıtma enerjisi, havalandırma değerleri vb. belirtilecektir.

(e)Kışla bölgesinde mevcut bir itfaiye merkezi, ısı merkezi veya su deposu olup olmadığı ve kapasiteleri/özellikleri yer alacaktır.

TASNİF DIŞI B-24

Page 39:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(f) Öneri raporu ile birlikte “Makine Tesisat Projesi İhtiyaç ve Koordinasyon Formu” tanzim edilecek, söz konusu rapor ilgili Kullanıcı Müdürlük, İstanbul Tersanesi Komutanlığı Kontrol Teşkilatı ve Proje Müellifi Firma yetkilileri tarafından imzalanacaktır.

(g)Öneri raporu mimari projeye uygun olarak hazırlanacaktır.

(h)Amortisman ve işletme masrafları nazara alınarak yapılan mukayese ve rantabilite hesaplarına dayanan ekonomik ve teknik etütleri kapsayacaktır.

(i) Bu etütler neticesi tesise uygulanması gerekli bulunan inşai ve mimari esaslar ve tesisat çeşitleri proje müellifi tarafından önerilecektir.

(j) Uygulanması ekonomik bulunacak sistem(ler)in mimari ve statik projelerinde uygulama yönünden gerektireceği tadilat belirtilecek, en ekonomik çözümde mimari, statik ve konum yönlerinden imkansızlıklar varsa, ekonomiklik sırasıyla, diğer çözümler önerilecektir.

(k)Ekonomi hesapları için gerekiyorsa 1/200 mimari proje ve idarece verilen vaziyet planı üzerinde mikyas değiştirilmeden öngörülen tesisat hacimleri ve gerekli bulunacak diğer bilgiler işaretlenecektir. Bunun dışında krokiler, şemalar, grafikler, veriler, müteakip safhalarda yararlanılacak doküman ve izlenecek hesap esasları belirtilecektir.

(l) Mukavelede aksi belirtilmemişse mukayese ve rantabilite hesaplarında projenin yapıldığı tarihte yürürlükte olan Çevre ve Şehircilik Bakanlığı Birim Fiyatları esas alınacaktır. Fiyatı bulunmayan kalemler için proforma fatura temin edilecektir.

(2)Mekanik Kesin Proje (1/100 Safhası)(a)Kesin proje; öneri raporunda kabul edilen tesisatın, boru ve kanallarının geçiş

yerlerini, yaklaşık boru çapı ve kanal ölçülerini gösteren, makine ve cihazların yerleşme şekillerini belirten, ayrıca proje ve hesaplara esas olacak verilerin ve hesap tarzlarının verildiği 1/100 ölçekli proje ve hesap raporundan oluşacaktır.

(b)1/100 ölçekli mimari projenin onayından sonra, makine tesisat projesi ihtiyaç kriterlerine göre, Kullanıcı Müdürlük ile Kontrol Teşkilatından alınacak bilgiler doğrultusunda hazırlanacaktır.

(c)Kesin proje; öneri raporunda önerilen ve onanma esnasında kabul edilen esaslara uygun olarak hazırlanacaktır.

(d)Uygulama projesine esas olacak ana veriler ve değerler hesaplanacak, kabuller tablolarla önerilecektir (uygulama projesinin yapımı için idarenin onayına sunulması gerekebilecek her çeşit hesap, veri veya tutum bu raporda önerilmiş veya onaya arz edilmiş olacaktır).

(e)Temin, depolama, sarf yerleri, kaynak ve gider yerleri ve karakterleri belirtilecek, bunlara göre hesaplara esas olacak boru ve kanal donanımı ve bütün gerekli donatım vaziyet planında ve 1/100 ölçekli kat planlarında gösterilecek, rapor için belirtilenlere paralel olarak, donanım ve donatıma ait 1/50 uygulama projelerinin yapımı için idarenin onayı alınması gerekebilecek her husus 1/100 projelerde gösterilmiş ve onaya arz edilmiş olacaktır.

TASNİF DIŞI B-25

Page 40:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(f) İlgili elektrik ve otomatik kontrol ana ve yardımcı tablolar, veya panolarının yerleri, çekilebilecek yaklaşık güç ve karakteristikleri vb. elektrik tesisatı projelerini etkileyebilecek bütün hususlar vaziyet planında ve 1/100 kat planlarında gösterilecektir.

(g)Mimari ve inşaat mühendisliği projelerini etkileyebilecek bütün hususlar kafi yaklaşıklıkla hesaplanacak veya çizilecektir/gösterilecektir. Bu projelerin uygulama safhasında proje yapımını aksatabilecek herhangi bir eksik veri bırakılmayacaktır.

(3)Mekanik Uygulama ve Detay Projesi ile Teknik Şartname (1/50 Safhası)

(a)Uygulama Projesi; onaylı ön projeye göre tesisatın uygulama safhası için gerekli bütün hesaplarla birlikte, dönen ve çalışan parça veya ünitelerin titreşim, ses emme ve genleşme hesaplarını ve bu sorunların giderilme tedbirlerini, kapasite ve güç ölçülerini de içine alan, tesislerin bütünü ile ilgili yerleşme ve kolon şemalarını kapsayan, uygulamanın tamamına yararlı kolon projeden müteşekkil bir proje ve hesap raporundan oluşacaktır.

(b)Tüm koordine işlemlerinin tamamlandığı ve kesin olarak ihtiyaçların belirlendiği 1/100 ölçekli proje safhasını müteakip, tesisteki sistemlere ait ısı, su ve pis su gideri bağlantılarını, sahaya ait ısı galerisini, tüm tesisat projelerinden ihale kapsamında yapılmasına ihtiyaç duyulan projeler bu safhada proje müellifi firma tarafından eksiksiz olarak idareye teslim edilecektir.

(c)Bu safhada, her paftada kullanılacak malzemeler ile ilgili tarifler için detay proje hazırlanacaktır.

(d)Projelerde inşaat kapsamında tedarik edilmeyecek olan cihazlar/sistemler kesikli çizgi ile gösterilecek bu cihazların İstanbul Tersanesi Komutanlığı tarafından “Birlik Temini” olarak tedarik edileceği özellikle belirtilecektir.

(e)Uygulama projeleri; 1/100 ölçekli ön proje safhasında yapılan düzeltmeler doğrultusunda hazırlanacak, projeler 10 takım, hesap raporları ise 4 takım halinde CD kopyası ile birlikte idareye teslim edilecektir.

(f) Uygulama projeleri; öneri raporu ile ön proje ve raporunda saptanan ve idarece onanan esaslara uygun olarak hazırlanacaktır.

(g)Uygulama projeleri esas itibariyle, 1/50 ölçekli kat planları, kolon şeması ve vaziyet planından oluşacaktır. Planlarında ve kolon şemasında kafi açıklıkta gösterilmeyen donanımı ve donatımı etkileyebilecek veya ilgili, mimari, statik elemanlar elektrik ve/veya otomatik kontrol donanımı ve donatımı da ilgili paftaların bir kenarında veya ilgili pafta belirtilmek şartıyla ayrı pafta olarak çizilecek, tanımlanacak ve gösterilecektir.

(h)Uygulama projesi raporu; her tesisat çeşidi bölümü öneri raporunda ve ön proje raporunda önerilen, kabul edilen veya hesaplanan bütün esasları (kabul edilmeyenler dahil) kısaca kapsayan açıklamayla başlayacak ve tesisat için projenin çiziminde, uygulamada veya işletmede lüzumlu olabilecek her hususun gerekli açıklık ve hassasiyetle incelenmesini veya hesaplanmasını ihtiva edecektir.

(i) 1/50 ölçekli kat planları; uygulanacak her donanım çeşidini, donatımını ve anlaşılabilmesi için gerekli kısmi ayırmaları, ölçülü kesitleri, büyültmeleri vb. raporlarda önerilmiş, kabul edilmiş veya hesaplanmış nitelik ve niceliklere uygun ve uygulama ve işletme yönlerinden gerekli olan (ölçü, tanımlama, açıklama vb.)

TASNİF DIŞI B-26

Page 41:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

bütün bilgileri ihtiva edecek şekilde çizilecektir. Gerekli mimari, statik elemanlar, elektrik ve/veya otomatik kontrol şemaları da aynı paftada çizilecektir. Ayrı paftada çizilirse açıklamayla bu husus belirtilecektir.

(j) 1/50 kolon şemaları; her donanım çeşidini düşey doğrultuda ölçekli olarak kapsayacaktır. Kat planları için belirtilmiş diğer hususlara da uyulacaktır.

(k)Havalandırma tesisatı kolon şemaları üç boyutlu olarak çizilecektir. Her kanal parçasında kesit, boy, birim direnç (mmss/m), cinsinden toplam direnç (mmss), debi, hız belirtilecektir. Her menfezde debi, hız, direnç, üfleme mesafesi, menfez veya anemostat cinsi açısı, damperli veya dampersiz olduğu, damper çeşidi gösterilecek, ilgili bütün elektrik ve otomatik kontrol prensip şemaları detayları kolon şemasının müsait bir kısmında çizilecektir. Ayrı çizilirse pafta numarası ile gerekli açıklamaya kolon şemasında da yer verilecektir. Sistem detaylarında ısıtıcı, soğutucu, kondenser, vantilatör, nemlendirici vb. elemanların imal edilebilmeleri için lüzumlu olan hava, su giriş ve çıkış sıcaklıklarına ve hesaba alınan direnç vb. bilgilere de yer verilecektir.

(l) Mimari uygulama projeleri 1/100 olarak kabul edilmişse, mükemmel anlaşılır hale getirmek üzere gerekli çalışmalar yapılacak ve makine tesisat uygulama projeleri de aynı ölçekli çizilecektir.

(m) Tip katlar mükemmel anlaşılır şekilde aynı kat planında gösterilecektir.

(n)Geniş bir katın ufak bir kısmında tesisat elemanları var, diğer kısmında hiç yoksa 1/100 veya 1/200 planda yeri, konumu belirtildikten sonra tesisat bulunan kısım 1/50 ölçekli çizilecektir.

Detaylar:

(a)Detay projeleri, tesisatın yoğun olduğu hacimlerin 1/20 (gerekirse 1/10) ölçekli plan kesit ve görünüşleri ile, tecrit detayları, kanal kesitleri, boru askı ve genleşme detayları ve benzeri kısımların uygulama için gerekli (ve 1/10, 1/5,1/2, 1/1, gibi uygun ölçekli) detay projelerini ve özel imalat için daha detaylı imalat resimlerini kapsayacaktır.

(b)Uygulama projelerinde, uygulama için yetersiz kalan kısımlarda küçültme veya büyütme yapılarak alınacak kesitler, montaj detayları, perspektif görünüşler yardımıyla bütün belirsizlikler giderilecek, detaylar arasında imalat projelerine yer verilmeyecek, ancak bazı cihazların yerleştirilme detayları yapılırken çeşitli imalatçı firmaların tip projelerine göre detaylar gerekirse çizilecektir.

Teknik Şartname:

Teknik şartname, EK-I’da bulunan Teknik Şartname Örneği formatında hazırlanacaktır.

(4)Mekanik Metraj, Keşif ve Yaklaşık Maliyet Safhası

(a)Makine tesisat projelerine göre metrajlar yapılacaktır.

(b)Birim fiyatı bulunmayan imalatlara ait Yeni Fiyat Zaptı yapılacak ve en az 3 adet proforma fatura verilecektir.

(c)Birim fiyat listesi hazırlanacaktır.

(d)Keşif özeti yapılacaktır.

TASNİF DIŞI B-27

Page 42:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(e)Ayrıca idare istediği takdirde, mevzuata uygun olarak idari şartname ve sözleşme tasarısının düzenlenmesini de kapsayan genel bir dosyayı talep edebilecektir.

c. Makine Tesisatı Projelerinde Bulunacak Hususlar

(1)Sıhhi Tesisat Projeleri

(a)Günlük, haftalık ihtiyaç miktarı hesabı yapılacaktır.

(b)İçme suyunun nasıl temin edileceği, debisi, nerede ve ne miktarda depo edileceği açıklanacaktır.

(c)Filtreleme, şartlandırma, ısıtma cihazları, gerekiyorsa; kapasiteleri, özellikleri, işlemden sonra depolanma düşünülüyorsa; yer ve hacimleri ile birlikte belirlenecektir.

(d)Kullanma suyu ihtiyaç miktarı temiz sudan ayrı düşünülüyorsa nereden ve nasıl temin edileceği, nerede ve nasıl depolanacağı, gerekliyse nasıl basınçlandırılacağı belirtilecektir.

(e)Boru donanımında;

Sıhhi Tesisat Projeleri Genel Teknik Şartname, TS. 1258, TS 828, TS 826, TS 827’ ye uygun olarak düzenlenecektir.

Temiz su, sıcak su ile pis su boruları için yükleme birimine göre hesap yapılacaktır. Boru çapları ve yükleme birimleri projelere işlenecek, kabul kriterleri hesap raporunda belirtilecektir.

Su deposu, hidrofor tankı, pompaların hesabı verilecektir.

Pompa seçimlerine esas olacak kritik devre hesapları verilecektir.

(2)Yangın Söndürme Tesisatı

(a)Yangın Söndürme Tesisatı; Makine Tesisatı Genel Teknik Şartnamesi ve 26 Temmuz 2002 gün ve Sayı 24827 sayılı Resmi Gazetede Yayınlanan “Binaların Yangından Korunması Hakkındaki Yönetmelikte” istenenlere uygun yapılacaktır.

(b)Suyla yangın söndürme tesisatında ihtiyaç duyulan suyun temini, depolanacağı yer ve miktarı açıklanacak ve gerekli bulunuyorsa basınçlandırılması, kullanılmasında ve boru donanımında uygulanacak prensipler belirtilecektir.

(c)CO2 li yangın söndürme tesisatında, gerekiyorsa bunun bir etütle tespiti, ihtiyaç duyulan yerler, sabit tesis gerekiyorsa depolama yeri, miktarı ve şartları, kullanılmasında ve boru donanımında uygulanacak prensipler verilecektir.

(d)Hortumları, serme ve bağlama gibi yeteneklere sahip eğitilmiş personel veya itfaiye görevlisi olmayan yapılarda TS EN-671’e uygun yuvarlak yarı-sert hortumlu yangın dolabı kullanılacaktır.

(3)Kirli Su ve Pis Su Tesisatı(a)Kirli su ve pis su tesisatında uygulanacak prensipler verilecektir.

TASNİF DIŞI B-28

Page 43:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(b)Kirli suyun ayrıca toplanıp, tahliye edilip kullanılması gerekiyorsa etüdü yapılacaktır.

(c)Pis suyun sağlığa zarar vermeyecek şekilde atılması için düşünceler ifade edilecektir.

(4)Yağmur Suyu Tesisatı

(a)Boru donanımında uygulanacak prensipler açıklanacaktır.

(b)Yağmur sularının atılmasında uygulanacak prensipler verilecektir.

(5)Mutfak Tesisatı

(a)Cihaz ihtiyaçları belirlenecektir.

(b)Gerekli inşaat alanının tespiti yapılacaktır.

(c)Gerekli soğuk oda hacminin tespiti yapılacaktır.

(d)Isıtma ve soğutmada yararlanılacak kaynaklar ve yerleri verilecektir.

(e)Yerleştirme ve donanımda uygulanacak prensipler belirtilecektir.

(f) Mutfak tesisatı projeleri, Makine Tesisatı Genel Şartnamesi esaslarına ve ilgili standartlara göre yapılacaktır.

(g)Makine ve cihazların kapasite hesapları, ihtiyaçlar göz önüne alınarak yapılacaktır. Yatay ve kolon şemaları çizilecektir.

(h)Soğuk oda hesapları, kullanıcı ihtiyaçları dikkate alınarak yapılacaktır.

(i) Mutfak makine ve cihazlarının sıcak su, soğuk su, buhar ve kondens bağlantıları gösterilecektir.

(j) LPG (veya doğalgaz) tesisatı projelendirilecektir.

(6)Çamaşırhane Tesisatı Projeleri

(a)Çamaşırhane tesisatı projeleri, Makine Tesisatı Genel Teknik Şartnamesi esaslarına ve ilgili standartlara göre yapılacaktır.

(b)Çamaşırhane makinelerinin kapasiteleri tespit edilirken, kişi sayısı, yıkama aralıkları dikkate alınacaktır.

(c)Çamaşırhane cihaz ve makinelerinin sıcak su, soğuk su, buhar ve kondens bağlantıları gösterilecektir.

(7)Havagazı ve LPG (SPG) Tesisatı

(a)İhtiyaç miktarının tespiti yapılacaktır.

(b)LPG tesisatında depolama miktarının tespiti yapılacaktır.

TASNİF DIŞI B-29

Page 44:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(c)Depolama yerleştirme ve donatımda uygulanacak prensipler belirtilecektir. Depo yerleşimi TS 1446’ya veya Tesisat ve Elektrik Projeleri Tip Detay Albümüne göre yapılacaktır.

(8)Sterilizasyon Tesisatı

(a)İhtiyaç yerlerinin nitelik ve kapasitelerinin tespiti yapılacaktır.

(b)Uygulanacak sistemin prensipleri açıklanacaktır.

(9)Merkezi Basınçlı Hava (Vakum, Azot Protoksit, Oksijen) Tesisatı

(a) İhtiyaç miktarlarının tespiti yapılacaktır.

(b) Depolanacak miktarların tespiti yapılacaktır.

(c) Depolama yerleştirme ve donatımda uygulanacak prensipler belirlenecektir.

(10) Kalorifer Tesisatı

(a)Isı ekonomisiyle ilgili mukayese ve rantabilite hesapları (dış duvarlar, pencereler, dış tavan vb. ısı kaybeden yüzeylerde ekonomik nitelik ve kalınlıkların tespiti) yapılacaktır.

(b)Tesis ilk yatırım ve işletme ekonomisi ile ilgili mukayese ve rantabilite hesapları (ısıtma sisteminin, ısıtıcı akışkan cins, basınç ve sıcaklığının, boru donanımının, tecrit cins ve kalınlıklarının, kazan cins ve adedinin, yakıt cins ve niteliklerinin vb. teknik ve ekonomik özelliklerin tespiti) yapılacaktır.

(c)Kazan dairesi, kömürlük (yağ yakıt deposu), kül depolama, kömür ve kül ulaşımı, eşanjör, boyler kolektör hacimleri, ısıtıcı klima santralları, imbisat deposu, havalık deposu yerleri vb. ısıtma ile ilgili hacimlerin binadaki konumu, sistem bakımından elverişli olup olmadıkları, alanları gibi hususlara yer verilecektir.

(d)Baca durumu incelenecektir.

(e)Kazan besleme ve doldurma suyunun nitelikleri belirlenecek ve gerekiyorsa şartlandırılması yapılacaktır.

(f) Kalorifer tesisatı projeleri, Makine Tesisatı Genel Şartnamesi TS 2164, TS 2192, TS 825 ve ısı tasarrufu ile ilgili yönetmeliklere uygun hazırlanacaktır.

(g)Binaların ısı kaybeden dış kabuk kısmına ait (dış duvarlar, pencereler, dış duvar üzerindeki kapılar, tavanlar, döşemeler) ısı tasarrufu ile ilgili hususlarda TS 825’e uygunluk sağladığı hesaplarla gösterilecektir. Yoğuşma ve buharlaşma grafikleri hesap raporunda verilecektir. Ölçekli vaziyet planı üzerinde yön gösterilecektir.

(h)Kazanların, genleşme depolarının, kondens depolarının, pompaların ve diğer elemanların hesabı verilecektir.

(i) Isıtma tesisatında 3 yollu vana ile otomatik kontrol yapılacak, kritik devrede 3 yollu vana kaybı dikkate alınacaktır.

(j) Bacaların hesabı TS 2165 ‘e göre yapılacaktır.TASNİF DIŞI B-30

Page 45:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(k)Boru çapı seçiminde su hızı en çok 1.2 m/sn alınacaktır. Bu hız ısıtıcıda 0.2 m/sn olacaktır.

(l) Isıtıcıların ve soğutucuların tipi, binaların fonksiyonlarına uygun olacak şekilde tayin edilecektir.

(m) Kazan dairesi boyutlandırması ve yapı tekniğinde yangın yönetmeliğine uyulacaktır.

(n)Sıvı yakıtlı ve doğalgazlı tip ısıtma sistemleri kapalı genleşmeli olarak projelendirilecektir.

(11) Brülor ve Yakıt Tesisat Projeleri

(a)Kullanılacak sıvı veya gaz yakıt cinsinin seçimi için gerekli teknik ve ekonomik etütler yapılacaktır.

(b)Donanıma ait prensipler belirtilecektir.

(c)Brülör tesisatı projeleri, TS 2192, DIN 4787’ye ve yangın yönetmeliğine uygun hazırlanacaktır.

(d)Yakıt deposu, pompa, ısıtıcı hesapları yapılarak gösterilecektir. Günlük yakıt tankı çıkışından akaryakıt sayacı projelendirilecektir.

(e)Brülör kapasite hesabı yapılacaktır.

(f) Yakıt deposu hesabı 20 günlük kullanıma göre yapılacaktır.

(g)Gaz yakıt kullanılacaksa, ilgili gaz armatürleri ve basınçlar göz önüne alınacaktır.

(12) Uzaktan Isıtma Tesisatı

(a)Tesisin ilk yatırım ve işletme ekonomisi ile ilgili mukayese ve rantabilite hesapları (uzaktan ısıtma sisteminin kazan dairesi yerinin ve konumunun, ısıtıcı akışkan cins, basınç ve sıcaklığının, boru donanımının; cins ve kalınlıklarının, kazan cins ve adedinin, yakıt cins ve niteliklerinin vb. teknik ekonomik özelliklerinin tespiti) yapılacaktır.

(b)Uzaktan ısıtılacak binaların eşanjör dairelerini, kotlarını, düşünülen kazan dairesi yerini belirten vaziyet planı çizilecektir.

(c)Baca durumunun yakıt ve varsa kül depolama ulaşımının etüdü yapılacaktır.

(d)Tesisat kanalları yönünden yer altı suyunun etüdü yapılacaktır.

(13) Otomatik Kontrol Tesisatı

(a)Tesisat elemanlarının yerleri yatay ve kolon şemalarında gösterilecektir.

(b)Otomatik kontrol vanalarının hesapları verilecektir.

(c)Bağlantı detayları verilecektir.TASNİF DIŞI B-31

Page 46:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(14) Havalandırma Klima Tesisatı

(a)Enerji ekonomisi ile ilgili mukayese ve rantabilite hesapları (dış duvarlar, pencereler, dış tavan, bina konumu vb. ısıtma ve soğutma yüklerine tesir eden hususlarda çeşitli özellik, nitelik veya kalınlıkların etüdü) yapılacaktır.

(b)Tesis ilk yatırım ve işletme ekonomisi ile ilgili (havalandırma, klima, ısıtma soğutma, otomatik kontrol sistemlerinin, santral yerlerinin, temiz hava emiş - kullanılmış hava atış yerlerinin, kanal ve tecrit cinslerinin özelliklerinin, kalınlıklarının vb. ekonomik ve teknik özelliklerinin tespiti) mukayese ve rantabilite hesapları yapılacaktır.

(c)Kompresör, santral, soğutma kulesi vb. klima elemanlarının ve ilgili ısıtma sistemine ait elemanların yerlerinin tespiti yapılacaktır.

(d)Boru ve kanal ana dağıtım prensipleri belirlenecektir.

(e)Havalandırma ve klima tesisatı projeleri, Genel Teknik Şartname, TS 3419, TS 3420, Bayındırlık Bakanlığı Yayınları, MMO 85 Numaralı Yayını, Carrier, ASHRE vb. yabancı literatür esaslarına göre yapılacaktır.

(f) Kanal hesabı yapılacak, projelerde kanal ölçüleri de gösterilecektir.

(g)Tesisatta bulunan cihazların kapasite hesapları yapılacaktır. Psikometri diyagramında gösterilecektir.

(h)Kanal izometrik şemaları verilecektir.

(15) Soğutma Tesisatı Projeleri

(a)Isı ve enerji ekonomisi ile ilgili mukayese ve rantabilite hesapları (soğuk oda tavan, duvar, döşeme tecritleri, kapı konstrüksiyonları vb. soğuk (frigo) kaybına sebep olabilecek hususlarda tecrit ve konstrüksiyon nitelik ve kalınlıklarının teknik ve ekonomik yönlerden etüdü) yapılacaktır.

(b)Tesisin ilk yatırım ve işletme ekonomisi ile ilgili (soğutma santrali yeri, sistemi, soğutucu cihaz ve soğutucu akışkan cinsi nitelikleri, soğutucu akışkanın soğutulması, soğutma kulesi veya evaporatif kondenser yeri, boru donanımı vb. tesisle ilgili ekonomik ve teknik özelliklerin tespiti) mukayese ve rantabilite hesapları yapılacaktır.

(c)Soğutma tesisatı projeleri, Makine Tesisatı Genel Şartnamesi ve DIN 8975 numaralı yayın esaslarına göre hazırlanacaktır.

(d)Isı kazancı hesapları yapılacaktır.

(e)Evaparatör, kompresör ve kondenserin kapasiteleri hesaplanacaktır.

(f) Sistemde varsa su soğutma kulesi seçimi yapılacaktır.

(g)Soğutma tesisatı elemanları, yatay ve kolon şemalarında gösterilecektir.

(h)Tesisata ait akış şeması veya izometri verilecektir.TASNİF DIŞI B-32

Page 47:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(16) Altyapı Projeleri (Isı Kanalları-Isı Galerileri)

(a)Ölçekli vaziyet planı üzerinde ısı kanalı güzergahı gösterilecektir.

(b)Kanal güzergahında boruların cinsi, çapı ve ısı yükleri belirtilecektir (90/70 Cº ısıtma, kullanma sıcak suyu, buhar, kondens, kızgın su, vb.).

(c) İzolasyon kalınlıkları ve cinsi belirtilecektir.

(d)Isı genleşme ve boru uzama hesapları yapılacak, genleşme parçalarının yerleri, boyutları ve hesabı verilecektir.

(e)Sabit ve hareketli mesnetlerin yerleri belirtilecek, detayları verilecektir.

(f) Malzeme sokma ve havalandırma menfezlerinin yerleri belirtilecek, kesit verilecek ve ölçümlendirilecektir.

(g)Isı kanalının mevcut sistemle bağlantısı varsa, vaziyet planında mevcut ve yeni yapılacak kısımlar gösterilecektir.

(h) Sıhhi tesisat projesinde yer alan bina atık su çıkışı rögar miktarı ve yeri kanalizasyon projeleri ile uyumlu olacaktır.

d. Makine Tesisatı Projelerinin Mimari, İnşaat, Elektrik ve Diğer Tesisat Projeleri ile Koordine Edilmesi

(1)Mimari Projelerle İlişkiler

(a)Tesisat kat planları onaylı mimari projeye uygun olarak hesaplanacak ve yerleştirilecektir. Projeyi yapan mimar tarafından veya idarece mimari projelerde yapılacak değişiklikler dolayısıyla, tesisat projelerinde gerekli düzeltmeler yapılacaktır.

(b)Öneri raporunda ısı hesaplarına göre saptanan pencere, duvar, izolasyon vb. hususlarda mimarlarla gerekli koordine sağlanacaktır.

(c)Gerek raporda gerekse plan ve kesitlerde mimari paraf için mimarca gerekli bulunacak ölçü, ağırlık, yerleştirme detayı, ses vb. hususlarda etüt ve çalışmalar yapılacaktır.

(d)Isı yalıtım hesabında çatı, duvar, döşeme plan ve kesitleri ile yalıtım detay resimleri, ısı köprüsü oluşturmayacak detayların bulunduğuna dair mimari koordine alınacaktır.

(2)İnşaat Mühendisliği Projeleriyle İlişkiler

(a)Tesisat kat planları, kolon şemaları, tesisat hesapları ve tesisatın yerleştirilmesi yönlerinden inşaat mühendisliği projelerinde gerekli düzeltmeler yapılacaktır.

(b)Ekonomik ve teknik yönlerden tesisatın gerektireceği tadilat hususunda inşaat mühendisliği projeleriyle kiriş, kolon, hatıl perde duvar vb. detaylardan geçişlerde uyumluluk sağlanacaktır.

TASNİF DIŞI B-33

Page 48:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

(c)Raporlarda, planlarda, kesit veya detaylarda, inşaat mühendisliği parafı alınmasında lüzum görülecek ölçü, ağırlık yerleştirme detayı, titreşim vb. hususlarda etüt ve çalışmalar yapılacaktır.

(3)Elektrik ve Otomatik Kontrol Tesisatı Projeleriyle İlişkiler

(a)Tesiste makine tesisat imalatına ait elektriksel güç ve diğer lüzumlu karakteristikler verilerek, cihaz listesinde belirtilecektir.

(b)Bir düğmeyle (veya şalterle) birlikte devreye girecek cihazlar gerekli bütün karakteristikleriyle belirtilecektir.

(c)Tesisata ait pompa, brülör, hidrofor vb. cihazların çalışması otomatik ise devreye girerken otomatik kontrol bağlantısının otomatik olarak temin edilip edilmeyeceği vb. gerekli bilgiler cihaz listesinde belirtilecektir.

(d)Birbirine bağlı olarak otomatik devreye giren cihazların ilişkileri, karakteristikleri vb. gerekli bilgiler birer sistem detayıyla belirtilecektir. Tabloda gerekli ikaz, alarm, emniyet vb. cihazlar tanımlanacaktır.

(e)Gerek makine tesisatı ve gerekse ilgili elektrik ve otomatik kontrol donanımı (cihaz, tablo vb.) için gerekli bulunabilecek donanım önerilecek, yer ve sistemi açıklanacaktır.

(f) Otomasyon sisteminde sistem senaryosu hazırlanacak ve bu sisteme ait izometrik plan verilecektir. Otomasyon projeleri elektrik tesisatı projeleri ile koordineli ve uyumlu olacaktır.

(4)Diğer Makine Tesisat Projeleriyle İlişkiler

(a) Makine tesisat projelerinin tamamının yapılması söz konusu değilse; ısıtma, su, gaz vs. her çeşit ilgili tesisat etüt edilecek ve projelendirilecektir.

(b) İlgili tesisat, diğer bir müellifçe hazırlanan kaynak veya kaynaklardan yararlanıyorsa; kolektöre kadar gerekli tesisat projelendirilecek ve kolektörde ilave edilecek yük belirtilecektir.

(c) Mevcut tesisattan yararlanılıyorsa yeni yüklere göre kaynaklar tekrar etüt edilecek ve uygunsa bağlantı yapılacaktır. İlave gerekiyorsa miktarı ve karşılanması için gerekli değişik çözümler mukayese edilecek, en uygun ve ekonomik çözüm önerilecektir.

(d) İlgili olmayan tesisat elemanlarından yerleştirmede göz önüne alınması gerekenler de ince dış çizgileriyle (gerekiyorsa kesitte alt ve üst çizgileri de belirlenecek) gösterilecek ve tanımlanacaktır.

(e) Mevcut tesislerin bulunduğu bölgeye yeni bir tesis yapıldığında veya mevcut bir bina onarımında mutlaka röleve verilecektir. Bölge içindeki su, ısıtma, kanalizasyon hatları etüt edilecektir.

(5)Diğer Mühendislik Hizmetleriyle Koordinasyon

(a)Makine Mühendisliği hizmetleri üzerinde etkisi olabilecek diğer mühendislik ve mimarlık hizmetlerini yapan birimlerden;

TASNİF DIŞI B-34

Page 49:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

Rapor, kolon şeması ve detayların lüzumlu bulunan sayfa veya paftalarında,

Kazan dairesi, tesisat odası, eşanjör dairesi, kalibrasyon merkezi, ameliyathane gibi özellik arz eden bina ve tesislerin bulunduğu paftalarda,

Vaziyet planında,

Bütün kat planlarında projenin onay hanesindeki ilgili bölümüne koordine parafı alınacaktır.

(b)Bina ve tesis için projeyi yapan teknik elemanların (Proje müellifinin mimar ve mühendisleri ve idarenin inceleme mimar ve mühendislerince ayrı ayrı olmak üzere) parafları tamamlanmışsa; makine tesisat projelerinde mevcut her çeşit donanımın diğer projeler üzerinde yapacağı bütün etkiler dikkate alınmış ve paraf edilen projeler diğer mühendislik veya mimarlık hizmetleri yönlerinden uygun bulunmuş kabul edilecektir .

TASNİF DIŞI B-35

Page 50:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

EK-CKULLANICI BİRLİGE AİT MAHAL KROKİSİ

ALT KAT PLANI

TASNİF DIŞI C-1

Page 51:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

ÜST KAT PLANI

TASNİF DIŞI C-2

Page 52:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

EK-ÇKULLANICI MÜDÜRLÜK İSTEK RAPORU

ZEMİN :Fabrika ortamınındaki zemininin toz oluşturmayan endüstriyel zemin kaplaması olması gerekmektedir.

67 C Fabrikasındaki kriptolu/şifreli cihaz onarım mahalli ve 67 A Fabrikasındaki Cayro/Cayro Test mahallinin zeminleri anti-statik malzeme ile kaplanmalıdır.

PENCEREAtölye binasının cephesinde bulunan pencere yapısı yenilenmeli çalışma alanları ve ofisler için uygun pencere yapısı haline getirilmelidir. Pencereler çift cam ve ısı izolasyonlu olmalıdır.

İZOLASYONSavaş Sistemleri Grup Müdürlüğü bağlısı fabrikaların ısı izolasyonları mutlaka sağlanmalıdır.

KATLARFabrikalar bina içine zemin kat ve asma kat şeklinde yerleşecektir. Savaş Sistemleri Grup Müdürlüğü bağlısı iki fabrikanın genel yerleşimi Ek-C de sunulmuştur. Atölye binası içine yerleşim planına uygun olarak asma katlar inşa edilmelidir.Giriş kapıları ile asma katların zemin kısmı yüksekliği yerden 5 mt yüksekliğinde olan bina dış çelik kuşak seviyesinde olacak şekilde dizayn edilmeli, üst asma katların yüksekliği ise proje çizimi esnasında cam seviyeleri yüksekliği dikkate alınarak değerlendirilmelidir. Üst asma katlar tamamen ofis şeklinde olacak ve ağır malzeme bulunmayacaktır. Ağır malzemeler zemin katta muhafaza edilecektir.

TUVALET/DUŞ75 personele yetecek sayıda tuvalet / lavabo ve banyolar yapılmalı emici fan sistem ile hava tahliyesi sağlanmalıdır.Asma katta bulunan ofis odası için planda gösterilen yerlerde tuvalet/lavabo ve banyo bulunacaktır.

ÇEVRE67A ve 67C Fabrikalarının kullandığı antenler için bina arka tarafına proje çizimi esnasında tarif edilecek şekilde anten faundeyşınları hazırlanmalıdır. Antenler için fabrika içerisinden kabloları çekilecektir.

ISITMAUygun çalışma ortamının sağlanabilmesi için fabrikaların tamamını kapsayacak şekilde ısıtma sistemi yapılmalıdır. Mevcut fabrikadaki split klimalar ilgili mahallerine taşınacaktır.

HAVAHer bir fabrikada tersane hava devresine iştirakli 6-8 barlık hava devresi olmalıdır.

KREYNBina içerisindeki mevcut kreyn’in taşıma gücünün değerlendirilmesi onarılması, gerekli elektriksel altyapı bağlantılarının yapılarak işlevsel hale getirlmesi gerekmektedir.

HAZIRLAYANLAR KONTROL EDENLER

TASNİF DIŞI Ç-1

Page 53:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

ELEKTRİK67A ve 67C Fabrikalarının Kullandığı antenlerin, sistemlerin ve personelin yıldırım riskine karşı korunması için paratoner sistemi yapılmalıdır.Her Fabrika için ana voltaj devresinin toprak hattının dışında, her çalışma masasına ulaşacak şekilde bağımsız bir toprak (arz) hattı çekilmeli, bakır arz çubuğu/levhası toprağa gömülmelidir.Taşınacak fabrikaların güç ihtiyacı için ilave bir tadilata ihtiyaç duyulmaktadır. Fabrikalar ihtiyaç duyacakları güç ihtiyaçlarını hali hazırda kullandıkları ve taşınma sırasında beraberinde getirecekleri jenaratör /inverter /konverter vb güç kaynakları ile karşılayacaklardır.

Yerleşim planına göre Fabrikalar içinde güç dağılımlarının yapılmasına ihtiyaç olacaktır. Bu kapsamda ;

(1). 67 C Muhabere Sistemleri Fabrikası için;

Üç Faz 380 VAC 100 Amper (Aynı zamanda 220 VAC, Üç Faz 115 VAC ihtiyaçlarını da karşılayacaktır) Üç Faz 115 VAC için mevcut trafo taşınacaktır.

(2). 67 A Elektronik Sistemleri Fabrikası için;

Üç Faz 380 VAC 100 Amper (Aynı zamanda 220 VAC , Üç Faz 115 VAC , Üç Faz 115 VAC 400Hz ihtiyaçlarını da karşılayacaktır.) Üç Faz 115 VAC ihtiyacı 67 C ye taşınacak trafo tarafından karşılanacaktır. Üç Faz 115 VAC 400 Hz için mevcut jenaratör taşınacaktır.

DATAFabrika için ihtiyaç duyulacak TSK-Net ve telefon hatları çekilmelidir.

KULLANICI MÜDÜRLÜK KOORDİNESİ :

HAZIRLAYANLAR KONTROL EDENLER

TASNİF DIŞI Ç-2

Page 54:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

EK-DZEM İN ETÜDLERİ KONTROL LİSTESİ

S.NO KONU/KRİTER Teknik Şartnamede

İstenen

Test Sonucu

Değerleri

1- SONDAJ DER İNLİĞİ :

a. Sondajda Ana kaya ile karşılaşılırsa bu tabakaya 3m girilecek, eğer Ana kaya çatlaklı bir yapıda ise bu tabakada 5 m ilerlenecek.

b. Sondaj zeminde devam ediyorsa sondaj derinliği en az 12m olmak kaydıyla, 3 kez üst üste SPT-N>50 değeri elde edilene kadar sondaja devam edilecektir. Sondaj derinliği hiçbir şekilde 12m’den, bodrumlu binalarda 15m’den, yapı yüksekliği 10 kat ve daha fazla ise 20m’den az olamaz.

c. Yukarıdaki şartlar gerçekleşmezse sondaj derinliği bina kısa kenarının (B) 1,5 katı olacaktır.

2- SONDAJ ADED İ :

a. Bina Oturma Alanı 500 m² ve aşağısı ise 2 adet sondaj, 500-1000 m² arası 3 adet sondaj >1000 m2 ise alanın dört köşesinden 1’er adet ve ortasından 1 adet olmak üzere toplam 5 adet sondaj yapılacaktır.

b. Çok sayıda binanın oturduğu büyük alanlarda sondaj derinliği ve sayısına idare karar verecektir.

Zemin profilinin çok değişmediği düz arazilerde iş kapsamında yer alan her bir bloğun oturma alanından 2’den az olmamak üzere kuru burgulu sistemle sondaj yapılır.

3- SONDAJ YER İNİN İŞARETLENMESİ :

a. İdarenin sondaj kuyusunu kontrol edebilmesi için derinlik boyunca PVC boru konulacak ve her türlü dış etkiye karşı korunması için tedbir alınacaktır.

TASNİF DIŞI D-1

Page 55:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

b. Sondaj yerleri rapor ekindeki vaziyet planı üzerine işaretlenecek ve fotoğraflanacaktır.

4- ZEM İN İNCELEME YÖNTEMİ :

a. SPT deneyi yapılacak, sismik ve elektrik yöntemler SPT, CPT veya plaka yükleme deneyleri olmadan uygulanmayacaktır.

5- YAPILACAK LABARATUAR ÇALIŞMALARI SONUCUNDA :

1) Zemin İndeks özellikleri

Kuru, doygun ve doğal birim hacim ağırlıkları İçsel sürtünme açısı Kohezyon Sıkışma yüzdesi Porosite Su muhtevası Attenberg limitleri ve diğer zemin karakteristikleri

Dane dağılımları2) Zemin emniyet gerilmesi

3) Zemin sınıfı ve Yerel zemin Grubu

(A,B,C,D) (Z1,Z2,Z3,Z4)

4) Zemin Hakim Periyodu (To)

5) Yatak Katsayısı

6) Yeraltı suyunun max/min seviyesi

7) Sıvılaşma riski bulunup bulunmadığı var ise hesapları, zeminde sıvılaşma riski tespit edilmesi durumunda sıvılaşmaya karşı alınacak önlemlerin (kazık, jetgrout, enjeksiyon, taş kolon vibroflotasyon, foraj, vibrokompaksiyon,vs.) hangisinin o bölge için en uygun olduğunun nedenleri ile birlikte üniversite yorumunda açık bir şekilde belirtilecektir.

8) Şev stabilitesi sorunu bulunup bulunmadığı ve uygulanabilecek optimum şev eğimi değeri

9) Oturma (tasman) hesapları

10) Zayıf zeminlerde herhangi bir zemin iyileştirmesinin gerekip gerekmediği, gerekiyorsa en ekonomik ve etkin çözüm hakkında tavsiye ile zemin iyileştirilmesi önerilen

TASNİF DIŞI D-2

Page 56:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

yerlerde yapılacak iyileştirme yöntemi teknik şartnamesi hazırlanacak, iyileştirmenin hedef değeri sağlanıp sağlanmadığı hususunda imalat sonrasında kullanılacak deney yöntemleri de şartnamede yer alacaktır.

11) Bu rapor hafriyat sırasında alınacak önlemler (şevli kazı, iksa vb.) sonuçları ihtiva etmelidir.

12) Zemin özelliklerine uygun klas zaptı düzenlenecektir. Zemin etüd raporlarında yer alacak oturma, zemin emniyet gerilmesi, sıvılaşma hesapları en az 2 yönteme göre ayrı ayrı yapılacaktır.

6-ZEMİN ETÜD RAPORU ONAYLARI a. Zemin etüd raporları, üniversitelerin inşaat mühendisliği bölümü, geoteknik ana bilim dalında görevli inşaat mühendisi öğretim üyesi tarafından yorumlanacak ve ilave bir rapor hazırlanacaktır. Bu yorumlar raporda yer alan bilgilerin tekrarı şeklinde değil, hesaplanan sonuç değerlerinin doğruluğu, kullanılabilirliği, vs. nin nedenleri ile birlikte açıklanmasından oluşacak geniş bir yorum şeklinde olacaktır.

Zemin etüt raporlarında en az bir inşaat mühendisi ile jeoloji / jeofizik mühendisinin de imzasının aranması zorunludur. Zemin etüt raporlarında Jeofizik mühendisleri odasının

da onayı alınacaktır.7- GENEL

a. Sondaj yerlerini ve genel vaziyeti gösteren fotoğraflar raporun ekinde yer alacaktır.

b. Raporun kapak sayfası olarak MSB lığı Standart Antet Formu kullanılacaktır.

TASNİF DIŞI D-3

Page 57:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

ÖRNEK PROJE ANTETLERİ EK-E

TASNİF DIŞI E-1

Page 58:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

EK-F

ÖRNEK YENİ FİYAT ANALİZİ FORMATI

İşin Adı : 1997-ORE-BET-001 Albüm Numaralı İstanbul Büyükçekmece Subay Orduevi A Blok Binasında Teknik Analiz Yapılması Hizmet Projesi Yapımı

Analiz No : YFZ.E01 Tarih :

Mayıs 2013

Yardımcı Poz no :

Proje No:

F.F.Uygulanacağı Poz:Analizin Adı : 1x18W DEKORATİF APLİK

ARMATÜRTARİFİ : Ö-1x18w metal gövde, mat opal cam, elektrostatik toz boyalı E27 duylu, 18w ampullü,koruma sınıfı IP-20 armatürün işyerinde temini, montajı, çalışır halde teslimi. her türlü işçilik, müteahhit kârı ve nakliye ile her nevi malzeme dahildir.

Poz No CinsiÖlçüBr

Miktarı

.....Yılı Br

fiyatı TutarıBölüm

ToplamıA Malzeme

YFZ.E01 1x18W DEKORATİF APLİK ARMATÜR MT 1 76,00 1,00 76,00

Karsız Toplam (TL) : 76,00

2013 YILI BİRİM FİYATI %25 Müteahhit Karı veGenel Giderler (TL) : 19,00

Genel Toplam (TL) : 95,00

Müteahhit Fiyat ve Maliyet Analiz Grup Başkanlığı

Kontrol Mühendisi İnceleyen Tetkik ve Tasdik ....../........../............

Kontrol Eden ONAY

TASNİF DIŞI F-1

Page 59:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

EK-GÖRNEK TEKN İK ŞARTNAME FORMATI

.......................................... Binası İnşaatı, İnşaat teknik şartnamesi kapsamında; ..................... İnşaatı Jeneratör Binası İnşaatı

Kanalizasyon Hattı İnşaatı

Çevre Düzenlemesi İnşaatı bulunmaktadır.

GENEL HUSUSLAR :....................................... Binası İnşaatı, İnşaat teknik şartnamesi kapsamında bulunan

işlere ait İmalatlar, onaylı projelere, proje kriterlerine ve şartnamede verilen hususlar ile mahal listesine bağlı olarak yürütülecektir. İmalatlar yapılırken projede belirtilen notlara uyularak gerekli imalatlar yapılacaktır. İnşaat esnasında kazı, yıkım ve sökümden çıkan malzemeler idarenin veya belediyenin yazılı izni ile göstereceği döküm yerine boşaltılacaktır. Döküm yerinin düzeltilmesi yapılacaktır. Tüm yıkım, söküm ve taşıma işleri fiziki çevreye zarar vermeyecek şekilde yapılacaktır. İmalatlar için gerekli olan her cins malzeme inşaat sahasına getirilecek, olumsuz hava ve çevre koşullarından korunacaktır. İnşaatların yapımı esnasında kaldırılan, bozulan veya hasar gören yol, altyapı, kaplamalı alan, yeşil alanlar vb. alanlar eski haline getirilecek şekilde onarılacaktır. Kullanılacak bütün yerli ve ithal malzemenin menşei idareye önceden bildirilecek ve idarenin onayı alınacaktır. İş kapsamında bulunan tüm işlerin yapımında kullanılacak malzemeler TSE veya TSEK belgeli olanlar kullanılmalı ve bunların belgeleri yüklenici tarafından idareye ibraz edilecektir. Projelerde belirtilen imalatların yapılabilmesi için gerekli iş iskeleleri (21.065, 21.066 vb. pozlarına uygun olarak) kurulacaktır. İnşaatlardaki dolgu mutlaka şartnamede ve onaylı projelerdeki pozuna uygun yapılacak, dolgunun cinsi ve uygun sıkıştırmanın yapıldığı tutanak düzenlenerek tespit edilecektir. İnşaatta beton dökümü yapılmadan önce taşıyıcı sisteme ait eleman boyutları (perde kolon, kiriş vb.), döşenen donatılar projesine uygun olarak yapıldığı tutanak düzenlenerek tespit edilecektir. Kullanılan betonların beton dayanımını tespit etmek için TS 500’e uygun yöntemle numune alınıp kırdırılacak ve deney raporları alınacaktır. Betonların üretilmesi, yerleştirilmesi ve bakımı ilgili yönetmeliklere uygun işlemler yapılacaktır. İnşaatta yapılan PVC ve alüminyum pencere ve kapı sistemlerinin garantisini içeren firmanın taahhüdü alınacaktır. Ankara Sanayi Odası Alüminyum Sanayi Meslek Komitesinin en son tarihli Alüminyum Doğrama Üretimi ve Montajında Uyulması gereken Asgari Teknik Kurallara uyulacaktır. Isı ve su izolasyonu mutlaka projesi ve şartnamesine uygun yapılacak ve tecrit tutanağı düzenlenecektir. Tüm tecrit işleri için yükleniciden noter tasdikli 5 yıllık taahhütname alınacaktır. Çatıların projesine ve tekniğine uygun yapıldığına ilişkin çatı tutanağı düzenlenecektir. Ahşap oturtma çatı tutanağında projesine ve şartnamesine uygun yapıldığı, gerekli su yalıtımının yapıldığı, rüzgar bağlantılarının uygun yapıldığı, kullanılmış kereste

kullanılmadığı, aşık mertek boyut ve aralıkları, çatı kaplama cinsi ve çatıya bağlantısı, kaplama tahtası kullanılıp kullanılmadığı, kullanılmışsa kalınlığı gibi bilgiler bulunacaktır.

TASNİF DIŞI G-1

Page 60:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

Çelik çatı ve imalatların tutanağında projesine ve şartnamesine uygun yapıldığı, gerekli su yalıtımının yapıldığı, makas, aşık, gergi çubuğu, kimyasal dübel vb imalatlarda kullanılan malzemelerin boyutlarının ve aralıklarının uygunluğu gibi bilgiler bulunacaktır. İnşaatta hatalı imalat yapılmış ise kırdırılıp projesine ve şartnamesine uygun yapılacaktır. İnşaatlarda her imalat başlangıcında mutlaka bir örnek bölüm yapılmalı, uygunluğunun idarece onayı müteakip imalata devam edilmelidir. İnşaatlarda proje ve şartnamesine uygun yapılan ancak sonradan kontrolü mümkün olmayan imalatların proje ve şartnamesine uygun yapıldığına dair tutanaklar düzenlenecektir. TS 825 standardına uygun olarak yapılacak ısı yalıtımlarında kullanılacak ekstrüde polistren köpüğün kalınlığı için tesisat raporu esastır. Yüklenici firma şantiyede gerekli emniyet tedbirlerini alacak, iş güvenliği için uygun uyarı levhalarını asması, ayrıca şantiyede çalıştırdığı personelin kaldığı binaları işçi sağlığı ve iş güvenliği tüzüğüne uygun olarak düzenlenecektir. Onaylı uygulama projelerinde ve teknik şartnamelerde gösterilen veya bahsedilen poz numaralarının imalat tariflerine ve sağlanması gereken standartlarına uygun olarak imalatlar yapılacaktır. Uygulama projeleri, işin sonunda, imalat değişikliklerini ve revizeleri ihtiva edecek şekilde yeniden tanzim edilerek As-Built proje haline getirilecektir. Mimari, statik, makine ve elektrik olarak ayrı ayrı tanzim edilecek As-Built projelerde, tüm cihazların hakiki ölçüleri ve şekilleri ile cihazların ve ekipmanların marka, model ve kapasiteleri ile bağlantılarını detaylı olarak gösterilecektir. As-Built projeler, geçici kabul tarihinden önce İdareye tek nüsha olarak verilecek ve gerekli kontrollerden sonra istenilen ilaveler ve değişiklikler yapıldıktan sonra geçici kabul aşamasında son halleriyle 4 takım ozalit ve 2 adet CD'ye aktarılmış şekilde İdare'ye teslim edilecektir.

2. MALZEME VE İŞ KALEMLERİNE AİT TEKNİK ÖZELLİKLER

2.1. YALITIM ŞAPI İMALATI:

B.B. Poz No : 19.101

TANIM : Harç içine karışan maddelerle yalıtım şapı yapılması.M2

TARİFİ : Yalıtım yapılacak yerin temizlenmesi, derzlerin ayıklanıp yıkanması, 1 m3 kum, 400 kg. çimento ve 12 kg. idarece kabul edilecek müteşekkül harçla ortalama 3,5 cm. kalınlıkta ve iki tabakada olmak üzere kendi tanımhanelerinde gösterildiği şekilde şap yapılması ve sulanması, her türlü malzeme ve kayıpları işçilik işyerinde yükleme yatay ve düşey taşımalar, boşaltma yüklenici karı ve genel giderler dahil 1 m2 şap yapılmasıdır.

Ölçü:

Yalıtım yapılan bütün yüzeyler projesinde ölçülür.

Notlar:

1- İdarenin yazılı izni ile uygulanır.

2- Kullanılacak gereçlerin orijinal ambalajlı olması, laboratuvar raporu bulunması şarttır. Bu yalıtım fazla su tazyiki olmayan mahallerde uygulanır.

KULLANILACAK MAHALLER : Onaylı projesine uygun olarak

.................................................................mahallerinde kullanılacaktır.

TASNİF DIŞI G-2

Page 61:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

2.2. İŞ İSKELESİ İMALATI:

B.B. Poz No :21.065 ve 21.066

TANIM : İş iskelesi (duvar için) 0-12.50 m yükseklikte (12.50 m dahil) M²

TARİFİ : Yapılarda dış kaplama, derz, dış sıva ve benzeri işleri için yapılan sabit ya da gezgin,ayaklı iskeleler, ya da asma iş iskelesi gibi geçici tesisler ve servis için,ya da tavan inşaatı, sıvası ve benzeri işlerde kullanılmak üzere iş iskelesinin yapılması, sökülmesi, her türlü malzeme ve zayiatı, işçilik, işyerindeki yükleme, yatay ve düşey taşıma, boşaltma ve genel giderler dahil iş iskelesi yapılmasıdır.

Ölçü :

a) Duvar, duvar kaplaması, sıva, derz ve benzeri işler için kullanıldığı takdirde: İskelenin oturduğu yüzey ile saçak alt yüzeyi arasındaki aralık yükseklik, iskele kurulan binanın dışının zemin kattaki uzunluğu genişlik olarak alınır.Genişlik ile yüksekliğin çarpımı iş iskelesi alanı kabul edilir.

b) Tavan sıvası ve benzeri işler için kullanıldığı takdirde: İskelenin oturduğu yüzey ile tavan arasındaki yüksekliğin 1.50 m. noksanı, iskele yüksekliği kabul edilir.  

Not :1) Tavan için iskele kurulmuş ve bedeli verilmiş ise tavanı çevreleyen duvar için ayrıca iskele bedeli verilmez.

2) İş iskeleleri binada bir kısmı işe ayrılmış ise, iskele kurulması gereken kısımlarda, iskelenin oturduğu zemin ile yapılan işin üst kenarı arasındaki yüzey iskele alanı olarak kabul edilir.

3) Bir yerde kurulan iş iskelesi o mahaldeki bütün iskelelik işler için yapıldığı kabul edilir. Ve iş iskelesi bedeli bir kere verilir.

TANIM : İş iskelesi (tavanlar için) 0-12.50 m yükseklikte(12.50 m dahil). M3

TARİFİ : Yapılarda dış kaplama, derz, dış sıva ve benzeri işleri için yapılan sabit ya da gezgin,ayaklı iskeleler, ya da asma iş iskelesi gibi geçici tesisler ve servis için,ya da tavan inşaatı, sıvası ve benzeri işlerde kullanılmak üzere iş iskelesinin yapılması, sökülmesi, her türlü malzeme ve zayiatı, işçilik, işyerindeki yükleme, yatay ve düşey taşıma, boşaltma ve genel giderler dahil iş iskelesi yapılmasıdır.

Ölçü : a) Duvar, duvar kaplaması, sıva, derz ve benzeri işler için kullanıldığı takdirde: İskelenin oturduğu yüzey ile saçak alt yüzeyi arasındaki aralık yükseklik, iskele kurulan binanın dışının zemin kattaki uzunluğu genişlik olarak alınır.Genişlik ile yüksekliğin çarpımı iş iskelesi alanı kabul edilir.

TASNİF DIŞI G-3

Page 62:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

EK-ĞÖDEME PURSANTAJ TABLOSU

İŞİN ADIGalvaniz Binasının Tadil Edilerek Ambar/Atölye Haline Getirilmesi Proje Hizmet Alımı

İŞİN YERİ İstanbul Tersanesi Komutanlığı (Pendik/İst)

HİZMET ALIMININ KONUSU

Galvaniz Binasının Tadil Edilerek Ambar/Atölye Haline Getirilmesi işi kapsamında İstanbul Tersanesi Komutanlığının ihtiyaçları doğrultusunda zemin etüdü ve raporu ile mimari, inşaat, mekanik ve elektrik proje ve şartnamelerinin hazırlanması, ihale dosyasının hazırlanarak idareye teslim edilmesi işlerini kapsamaktadır.

1. RÖLEVE TADİLAT PROJELERİ % 15

1.A. Mimari Röleve Projelerin Hazırlanması %5 1.B. Mekanik Röleve Projeleri ve Öneri Raporunun

Hazırlanması %5 1.C. Elektrik Röleve Projeleri ve Öneri Raporunun

Hazırlanması Aydınlatma Tesisatı Planı Priz Tesisatı Planı Mekanik Tesisat Kuvvet Planı Tablo ve Pano Besleme Planı Kablo Taşıma Planı (PVC ve Tava) Topraklama ve Yıldırımdan Koruma Tesisatı Planı

%5

2. UYGULAMA TADİLAT PROJELERİ % 65 2.A. Mimari Uygulama Projeleri ile Detay Projelerinin

Hazırlanması %102.A.1. Mimari Uygulama ve Detay Projelerin Hazırlanması (1/50, 1/20,

1/5, 1/1 ölçeklerinde) (4 Takım) Kat Planlarının Hazırlanması (1/50 ölçeğinde) Kesitlerin Hazırlanması (1/50 ölçeğinde) Görünüşlerin Hazırlanması (1/50 ölçeğinde) Mahal Listelerinin Hazırlanması Detayların Hazırlanması (1/20, 1/5, 1/1 ölçeklerinde) Sistem Detaylarının Hazırlanması (1/20, 1/5, ölçeklerinde) Islak Hacim Detaylarının Hazırlanması (1/20, 1/5 ölçeklerinde) Doğrama Detaylarının Hazırlanması (1/20, 1/5 ölçeklerinde) Çatı Detaylarının Hazırlanması ( 1/50, 1/20, 1/5 ölçeklerinde) Dolap Detaylarının (Gömme dolap, vestiyer, banko, mutfak/banyo

dolapları vb.) Hazırlanması (1/20, 1/5, 1/1 ölçeklerinde) Mantolama Detaylarının Hazırlanması (1/20, 1/5, 1/1 ölçeklerinde) Merdiven Detayların Hazırlanması (1/20, 1/5, 1/1 ölçeklerinde) İzolasyon, döşeme detaylarının hazırlanması (1/50, 1/20, 1/5, 1/1

ölçeklerinde)2.A.2. Çevre Tanzim Projelerin Hazırlanması (üzerinde 1/20 sistem

detayları ile 1/5, 1/1 nokta detayları da bulunacaktır.) ( 1/500, 1/200 ölçeklerinde) (4 Takım)

2.A.3. İnşaat Teknik Şartnamesinin Hazırlanması 2.B Statik Uygulama Projeleri ile Detay Projelerinin

Hazırlanması %25

HAZIRLAYANLAR KONTROL EDENLER

TASNİF DIŞI Ğ-1

Page 63:  · Web viewKaba inşaatın döşeme üstü ve varsa düşük döşeme kotları (arazide röperlenmiş 0.000 kotuna göre) belirtilir. Sabit röpere göre görünüşe akseden pencere

TASNİF DIŞI T.Ş. NU. : 73401242-BYD-TŞ-2016/18

2.B.1.Zemin Etütlerinin Yapılması ve Rapor Haline Getirilmesi2.B.2.Statik Projelerin Hazırlanması (1/50) Ölçeğinde) (4 Takım) (Detayı,

Teknik Şartnamenin statik proje hazırlama kısmında yazılıdır.)2.B.3.Altyapı Projesi Hazırlanması (Binaya getirilecek elektrik besleme,

telefon, su, kanalizasyon, yağmur suyu, ısı, hatları için galeri ve/veya toprakaltı en/boy/ kesit ve detaylarını kapsar) (4 Takım) (1/500, 1/200, 1/50, 1/20, 1/5, 1/1 ölçeklerinden uygun olanı) (Detayı, Teknik Şartnamenin Alt yapı proje hazırlama kısmında yazılıdır.)

2.Ç Makine Tesisatı Uygulama Projeleri ile Detay Projelerinin Hazırlanması %15

Vaziyet Planının Hazırlanması Sıhhi Tesisat (Temiz Su Tesisatı, Pis Su Tesisatı) Projesinin

Hazırlanması Isı Yalıtımı Hesabının Yapılması, Isıtma Tesisatı (Kalorifer Tesisatı)

Projesinin Hazırlanması Yangın Tesisatı Projesinin Hazırlanması Havalandırma Projesinin Hazırlanması Altyapı Projeleri(Isı, temiz su, pis su, yangın bağlantılarını gösteren)

Hazırlanması Hesap Raporunun Hazırlanması Makine Teknik Şartnamesinin Hazırlanması

2.D Elektrik Tesisatı Uygulama Projeleri ile Detay Projelerinin Hazırlanması %15

1. Elektrik Kuvvetli Akım Tesisatı Projesi (1/50 ölçekli)• Aydınlatma Tesisatı Planı • Priz ve UPS Tesisatı Planı• Mekanik Tesisat Kuvvet Planı• Priz Kutusu Tesisat Planı• Tablo ve Pano Besleme Planı• AP-380/220V 50 Hz Panosu Kolon Şeması• AP-115/65 V 400 Hz Panosu Kolon Şeması (Mevcut Jenaratör/İnverter/Konverter Kullanılacak Şekilde)• Kablo Taşıma Planı (PVC ve Tava)• Ana Kolon ve Tek Hat Şeması, Yükleme Cetveli

2. Topraklama ve Yıldırımdan Korunma Tesisatı Projesi (1/50 ölçekli)• Topraklama Tesisat Planı (Bina İçi Her Kullanıcı Masasına Olacak Şekilde)• Topraklama ve Paratoner Tesisat Planı

3. Zayıf Akım Tesisatı Projesi (1/50 ölçekli)• İnternet, İntranet ve Telefon Tesisat Planı• Yangın Algılama ve İhbar Tesisatı Planı• Zayıf Akım Kolon Şeması

4. Vaziyet Planı-Enerji Getirme Projesi (1/50 ölçekli)• Vaziyet Elektrik Tesisat Planı• Vaziyet Elektrik Kablo Güzergah Planı

5. Elektrik Tesisat Teknik Şartnamesinin Hazırlanması6. Hesap Raporlarının Hazırlanması

3. METRAJ, KEŞİF VE YAKLAŞIK MALİYET % 20Hazırlanan projelere ve teknik şartnamelere göre keşif, metraj, yaklaşık maliyet, pursantaj, mahal listesi ile ihale dokümanlarının hazırlanması ve proje, ekleri dahil tüm evrakların 4 nüsha halinde CD ortamında ve ıslak imzalı olarak idareye teslim edilmesi.

% 20

GENEL TOPLAM %100

TASNİF DIŞI G-2