year end presentation 20171228 - osaka...
TRANSCRIPT
![Page 1: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/1.jpg)
KOTO実験における中性子背景事象削減のためのMPPC読出し用回路の
開発
Yamanaka Taku Laboratory Yuta Sato
1
![Page 2: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/2.jpg)
• KOTO experiment
2
KOTO detector
KL
CsI crystals are placed in vacuum
![Page 3: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/3.jpg)
• Background
3
Halo neutrons make 2γ-like events
BG
![Page 4: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/4.jpg)
• Both-end readout of the CsI calorimeter
4
The depth of the shower made by neutrons and photons are different
![Page 5: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/5.jpg)
• Both-end readout of the CsI calorimeter
5
The depth of the shower made by neutrons and photons are different
↓Calculate the position of the interaction by
measuring the timing difference
![Page 6: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/6.jpg)
• Purpose
6
• Develop the circuit for the MPPC-side of the both-end readout
• To develop
• Connection between MPPCs ← Today's main topic
• Amplifier circuit
MPPCAmplifierADC CsI PMT
VacuumLow-power amplifier required
![Page 7: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/7.jpg)
• Whole schematic of the install
7
4096 MPPCs in total
# of CsI Calorimeters:2240(Small) + 476(Large)
5 cm
5 cm2.5 cm
2.5 cm
Amplifier boards around CsI crystals
+HV ReadoutAmplifier
(Sum Amp.)
256 ch
2 m
Sensor size:6 mm × 6 mm
HPKS13360-6050CS
4 MPPCs
4 MPPCs
4 MPPCs
4 MPPCsSmall # of readout channels
4096 MPPCs → 256 readout channel
![Page 8: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/8.jpg)
• Connection methods for MPPCs
8
Series connection
Beam hole
High radiation dose
Stacked CsI crystals
Distance from the beam axis [cm]
Neu
tron
flue
nce
Simulated by H. Nanjo
+HV
Readout
![Page 9: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/9.jpg)
• Connection methods for MPPCs
9Vi' ≠ Vi
![Page 10: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/10.jpg)
• Connection methods for MPPCs
10
+V
OUT DC component AC component
Hybrid connection
+V
OUTResistance and capacitance shorten the time constant
Parallel connection
MEG Ⅱ usesthis method
![Page 11: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/11.jpg)
11
+HV Amplifier circuit(1 ch)
RJ45
OUT-
OUT+
• Readout circuit
Power consumption:55 mW / ch→ 14 W in total (256 ch)
Low power
4 MPPCs
4 MPPCs
4 MPPCs
4 MPPCs
![Page 12: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/12.jpg)
• Waveforms (all MPPCs are viewing photons from LED)
12
Red: HybridGreen: ParallelBlack: Series
Time [μs]
Voltage [V]
Time constant: Series ~ Hybrid < Parallel Pulse height: Series ~ Hybrid > Parallel
![Page 13: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/13.jpg)
• Cosmic ray test at J-PARC
13
Setup
• Compare the timing resolution between parallel and hybrid connection
![Page 14: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/14.jpg)
• Cosmic ray test at J-PARC
14
Trigger position
Timing difference
T(MPPC) - T(PMT)
T
0.5 × Peak
Timing difference [ns]
#Waveform (MPPC)
Example ExampleTiming resolution:σ of the distribution
![Page 15: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/15.jpg)
• Cosmic ray test at J-PARC
15
Red:ParallelGreen:Hybrid
Trigger position
Timing resolution [ns]
<Timing resolution>Parallel:(1.65 ± 0.03) nsHybrid:(1.45 ± 0.03) ns
Trigger position
Timing resolution
PMT sideMPPC side
<1.7 ns required
![Page 16: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/16.jpg)
• Summary
16
• Prospects
• Evaluating the performance of two connection methods for 4-MPPCs
• Developed the amplifier board to readout signals from MPPCs
• Timing resolution of the readout system satisfies the requirement
• Understand and solve the problems found during the beamtest
![Page 17: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/17.jpg)
Backup
17
![Page 18: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/18.jpg)
• KOTO Experiment
18
Linac Rapid Cycle Synch. Main Ring
Linac RCS MRHadron Beam Facility400 MeV 3 GeV 30 GeV
J-PARC
![Page 19: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/19.jpg)
19
![Page 20: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/20.jpg)
Figures
20
![Page 21: Year end presentation 20171228 - Osaka Universityosksn2.hep.sci.osaka-u.ac.jp/2017Nenmatsu/slides/...2017/12/28 · # of CsI Calorimeters: 2240(Small) + 476(Large) 5 cm 5 cm 2.5 cm](https://reader034.vdocuments.pub/reader034/viewer/2022042321/5f0ad1227e708231d42d7c86/html5/thumbnails/21.jpg)
21
MPPC CsI5 cm × 5 cm × 50 cm PMT
Plastic scintillators
Plastic scintillators
Cosmic ray654321
ADC