04 actuator engl
DESCRIPTION
Actuators used in stepless capacity control of recip-compressorsTRANSCRIPT
-
Jan_06 HydroCOM Actuator 1
V
P
HydroCOM
ActuatorActuator
Jan_06 HydroCOM Actuator 2
Actuator components
Seal HousingVent
Leakage oilFlare line
Optional: Seal gasSealing elements
Temperature sensor
Seal HousingVent
Leakage oilFlare line
Optional: Seal gasSealing elements
Temperature sensor
Valve HousingOil inlet
Solenoid valveHigh pressure piston
Oil outlet
Valve HousingOil inlet
Solenoid valveHigh pressure piston
Oil outlet
Electric Housing48VDC connectionHydroCOM field bus
Electric Housing48VDC connectionHydroCOM field bus
-
Jan_06 HydroCOM Actuator 3
Valve housing componentsInlet Nozzle:Controls unloaderspeed
Solenoid valve
High pressure piston
Check valve
Soft touch damper: Reduces closing impact speed of suction valve sealing element
Jan_06 HydroCOM Actuator 4
1.4.4
Valve housing Solenoid valveStroke 0,2mmSwitching time 1 msVoltage 48 VStarting current 14 A Holding current 4,5 A
coilcontrolpiston
valveseat
return spring
anchor plate
No power supply: unloaded;provided there is hydraulic pressure
-
Jan_06 HydroCOM Actuator 5
Valve housing - High pressure piston
Oil returnfrom
circulargroove
Highpressure
piston
O-ring
Conical metallic sealing
Cylinder
Oil
Jan_06 HydroCOM Actuator 6
Valve housing Check valve
Valvepiston
Spring
Valve seat
Max. hydraulic pressure in actuator during unloading > hydraulic unit operating pressure=> Check valve required
-
Jan_06 HydroCOM Actuator 7
Valve housing Inlet Nozzle
Solex nozzle: specifically engineeredfor each application. (Dia 0.3 to 1.0 mm)
Oil
Inlet strainerKY2007
Solex nozzle
Jan_06 HydroCOM Actuator 8
Valve housing Soft touch damper
returnspring
valveseat
jet nozzle
throttlepiston
Length of throttle piston calculated for each application
-
Jan_06 HydroCOM Actuator 9
Valve housing Soft touch damper
Return spring
Valve seatValve seat Jet nozzleJet nozzle
Throttle piston
Stroke of throttle piston
oil out
oil out
Jan_06 HydroCOM Actuator 10
Valve housing Solenoid cooling
-
Jan_06 HydroCOM Actuator 11
Valve housingWorking Oil, Cooling Oil and Oil Leakage
Cooling and leakage oil
anchor plate of solenoid valve
Please note:Picture shows
old actuator version.
Design details differfrom version 2001.
Working oil
Oil
Jan_06 HydroCOM Actuator 12
Valve housing Recovery and leakage oil
Oil Recovery System
connected to the hydraulic unit
Leakage oil
leakageleakage
-
Jan_06 HydroCOM Actuator 13
Terminals -solenoid
Cable for oil pressure sensor
(old design)
Cable for temperature sensor
Socket for connectionto electric housing
Valve housing Electronic parts
Jan_06 HydroCOM Actuator 14
Pressure sensor
Throttle plate to dampen pressure peaks
Soldered connections
Valve housing Pressure sensor(not supplied for new projects since 2001)
-
Jan_06 HydroCOM Actuator 15
Seal housing
flare connection
dynamic seals
wiper ringguides
static seals
Jan_06 HydroCOM Actuator 16
Seal housingGasket between valve & seal housing
old design: O-Ring
latest design: Gasket
-
Jan_06 HydroCOM Actuator 17
Seal housing NACE/toxic applications
Flare gas
Purge gas (N2)Oil Leakage
N2to flare
to ambient
Jan_06 HydroCOM Actuator 18
Seal housing materials
Version Viton Fluorsilicone Simriz
Dynamic seal:O-Ring Viton (FPM) Fluorsilicone (FVMQ) Simriz (FFKM)Glyd-Ring Turcon Turcon Turcon
Static seal:O-Ring Viton (FPM) Fluorsilicone (FVMQ) Simriz (FFKM)
Wiper :O-Ring Viton (FPM) Fluorsilicone (FVMQ) Simriz (FFKM)Wiper-Ring Turcon Turcon Turcon
Typical Natural Gas Ethylene H2S, applicationH2,N2,CO2 Ammonia, LDPE,
Remark:Turcon is a composite made of TeflonViton O-rings may have different colorsGuides are always PTFE
-
Jan_06 HydroCOM Actuator 19
Cable glands for bus cable
Protective Earth Connections
Electric housing Connection housing
Terminals for powersupply (+, -) and
bus cable (A, B, GND)
Cable gland for power cable
Jan_06 HydroCOM Actuator 20
Electric housing - Electronics
Current control for operation of solenoid coil
Communication with SIM in CIU via data bus
Interface for temperature sensor in actuator
Real time data processing for valve actuation which is synchronized with top dead centre signal
-
Jan_06 HydroCOM Actuator 21
capacitor for balancingthe fluctuating current
consumption of the solenoid
Connectorto valve housing
The rotary switchdefines the bus address
of the actuator
Electric housing Bus address / TerminationActuator 4
BusAddress Termination
(ON = active)
ON
6
F0
21
34 5 7 89AB
CDE
BusAddress Termination
(ON = active)
ON
6
F0
21
34 5 7 89AB
CDE
6
F0
21
34 5 7 89AB
CDE
Jan_06 HydroCOM Actuator 22
Termination by RC-Module(to be installed only in the last actuator of a bus line)
Electric housing Bus address / TerminationActuator 2
BusAddress
BusAddress
JUMPERS FOR BUS ADDRESSHydroCOM 2.0
Address Coding
1
2
3
4
5
6
8
7
Address Coding+53210
+53210+53210+53210+53210
+53210
+53210
+53210
on picture selectedaddress = 2
ATTENTION: do not use a RC-Module on a HydroCOM 4.0 Electric housing
use the internal resistor switch
-
Jan_06 HydroCOM Actuator 23
Electric housing Temperature sensor
TemperatureSensor
Coax connector
Jan_06 HydroCOM Actuator 24
HydroCOM is certified for ATEX, FM, CSA, Japanese standard:
ATEX Ex II 2G EEx de IIB + H2 T4US AEx de IIB + H2 T4FM Class 1, Div. 1, Group B, C, D, T4CSA Class 1, Div. 1, Group A, B, C, D, T4Japan Ex de IIB + H2 T4
Two types types of electric housings:
de: flameproof, increased safety (ATEX)d: flameproof (FM Div. 1)
Ex-Certificates
-
Jan_06 HydroCOM Actuator 25
Flare line G 1/8
Oil outlet G 3/8 female (old version: M14x1,5)
Venting to ambient
Leakage oil G 1/8
Oil inlet female G1/2(old version: Parker 16S)
HydroCOM Actuator Connections
ATEX version:3 x M20x1.5
Jan_06 HydroCOM Actuator 26
HydroCOM Actuator Workshop testingAfter assembly
Valve housing:2 hour leakage test at 150 bar
Valve housing:High pressure dynamic test at 8000N:Criteria: 10mm travel of high pressure piston must take at least 4s
Electric function test of complete actuator
8000N
-
Jan_06 HydroCOM Actuator 27
Spare Actuator Adoption
Following parts must be in accordance with the partlist for the compressor and actuator the spare actuator is intended to be used:
- Solex Nozzle (diameter)- Soft touch damper: length of throttle piston- Seal housing design / sealing materials- Is integrated oil pressure sensor required?- Correct bus address- Termination yes/no
(must be set for last actuator on the bus)