  • Jan_06 HydroCOM Actuator 1

    V

    P

    HydroCOM

    ActuatorActuator

    Jan_06 HydroCOM Actuator 2

    Actuator components

    Seal HousingVent

    Leakage oilFlare line

    Optional: Seal gasSealing elements

    Temperature sensor

    Seal HousingVent

    Leakage oilFlare line

    Optional: Seal gasSealing elements

    Temperature sensor

    Valve HousingOil inlet

    Solenoid valveHigh pressure piston

    Oil outlet

    Valve HousingOil inlet

    Solenoid valveHigh pressure piston

    Oil outlet

    Electric Housing48VDC connectionHydroCOM field bus

    Electric Housing48VDC connectionHydroCOM field bus

  • Jan_06 HydroCOM Actuator 3

    Valve housing componentsInlet Nozzle:Controls unloaderspeed

    Solenoid valve

    High pressure piston

    Check valve

    Soft touch damper: Reduces closing impact speed of suction valve sealing element

    Jan_06 HydroCOM Actuator 4

    1.4.4

    Valve housing Solenoid valveStroke 0,2mmSwitching time 1 msVoltage 48 VStarting current 14 A Holding current 4,5 A

    coilcontrolpiston

    valveseat

    return spring

    anchor plate

    No power supply: unloaded;provided there is hydraulic pressure

  • Jan_06 HydroCOM Actuator 5

    Valve housing - High pressure piston

    Oil returnfrom

    circulargroove

    Highpressure

    piston

    O-ring

    Conical metallic sealing

    Cylinder

    Oil

    Jan_06 HydroCOM Actuator 6

    Valve housing Check valve

    Valvepiston

    Spring

    Valve seat

    Max. hydraulic pressure in actuator during unloading > hydraulic unit operating pressure=> Check valve required

  • Jan_06 HydroCOM Actuator 7

    Valve housing Inlet Nozzle

    Solex nozzle: specifically engineeredfor each application. (Dia 0.3 to 1.0 mm)

    Oil

    Inlet strainerKY2007

    Solex nozzle

    Jan_06 HydroCOM Actuator 8

    Valve housing Soft touch damper

    returnspring

    valveseat

    jet nozzle

    throttlepiston

    Length of throttle piston calculated for each application

  • Jan_06 HydroCOM Actuator 9

    Valve housing Soft touch damper

    Return spring

    Valve seatValve seat Jet nozzleJet nozzle

    Throttle piston

    Stroke of throttle piston

    oil out

    oil out

    Jan_06 HydroCOM Actuator 10

    Valve housing Solenoid cooling

  • Jan_06 HydroCOM Actuator 11

    Valve housingWorking Oil, Cooling Oil and Oil Leakage

    Cooling and leakage oil

    anchor plate of solenoid valve

    Please note:Picture shows

    old actuator version.

    Design details differfrom version 2001.

    Working oil

    Oil

    Jan_06 HydroCOM Actuator 12

    Valve housing Recovery and leakage oil

    Oil Recovery System

    connected to the hydraulic unit

    Leakage oil

    leakageleakage

  • Jan_06 HydroCOM Actuator 13

    Terminals -solenoid

    Cable for oil pressure sensor

    (old design)

    Cable for temperature sensor

    Socket for connectionto electric housing

    Valve housing Electronic parts

    Jan_06 HydroCOM Actuator 14

    Pressure sensor

    Throttle plate to dampen pressure peaks

    Soldered connections

    Valve housing Pressure sensor(not supplied for new projects since 2001)

  • Jan_06 HydroCOM Actuator 15

    Seal housing

    flare connection

    dynamic seals

    wiper ringguides

    static seals

    Jan_06 HydroCOM Actuator 16

    Seal housingGasket between valve & seal housing

    old design: O-Ring

    latest design: Gasket

  • Jan_06 HydroCOM Actuator 17

    Seal housing NACE/toxic applications

    Flare gas

    Purge gas (N2)Oil Leakage

    N2to flare

    to ambient

    Jan_06 HydroCOM Actuator 18

    Seal housing materials

    Version Viton Fluorsilicone Simriz

    Dynamic seal:O-Ring Viton (FPM) Fluorsilicone (FVMQ) Simriz (FFKM)Glyd-Ring Turcon Turcon Turcon

    Static seal:O-Ring Viton (FPM) Fluorsilicone (FVMQ) Simriz (FFKM)

    Wiper :O-Ring Viton (FPM) Fluorsilicone (FVMQ) Simriz (FFKM)Wiper-Ring Turcon Turcon Turcon

    Typical Natural Gas Ethylene H2S, applicationH2,N2,CO2 Ammonia, LDPE,

    Remark:Turcon is a composite made of TeflonViton O-rings may have different colorsGuides are always PTFE

  • Jan_06 HydroCOM Actuator 19

    Cable glands for bus cable

    Protective Earth Connections

    Electric housing Connection housing

    Terminals for powersupply (+, -) and

    bus cable (A, B, GND)

    Cable gland for power cable

    Jan_06 HydroCOM Actuator 20

    Electric housing - Electronics

    Current control for operation of solenoid coil

    Communication with SIM in CIU via data bus

    Interface for temperature sensor in actuator

    Real time data processing for valve actuation which is synchronized with top dead centre signal

  • Jan_06 HydroCOM Actuator 21

    capacitor for balancingthe fluctuating current

    consumption of the solenoid

    Connectorto valve housing

    The rotary switchdefines the bus address

    of the actuator

    Electric housing Bus address / TerminationActuator 4

    BusAddress Termination

    (ON = active)

    ON

    6

    F0

    21

    34 5 7 89AB

    CDE

    BusAddress Termination

    (ON = active)

    ON

    6

    F0

    21

    34 5 7 89AB

    CDE

    6

    F0

    21

    34 5 7 89AB

    CDE

    Jan_06 HydroCOM Actuator 22

    Termination by RC-Module(to be installed only in the last actuator of a bus line)

    Electric housing Bus address / TerminationActuator 2

    BusAddress

    BusAddress

    JUMPERS FOR BUS ADDRESSHydroCOM 2.0

    Address Coding

    1

    2

    3

    4

    5

    6

    8

    7

    Address Coding+53210

    +53210+53210+53210+53210

    +53210

    +53210

    +53210

    on picture selectedaddress = 2

    ATTENTION: do not use a RC-Module on a HydroCOM 4.0 Electric housing

    use the internal resistor switch

  • Jan_06 HydroCOM Actuator 23

    Electric housing Temperature sensor

    TemperatureSensor

    Coax connector

    Jan_06 HydroCOM Actuator 24

    HydroCOM is certified for ATEX, FM, CSA, Japanese standard:

    ATEX Ex II 2G EEx de IIB + H2 T4US AEx de IIB + H2 T4FM Class 1, Div. 1, Group B, C, D, T4CSA Class 1, Div. 1, Group A, B, C, D, T4Japan Ex de IIB + H2 T4

    Two types types of electric housings:

    de: flameproof, increased safety (ATEX)d: flameproof (FM Div. 1)

    Ex-Certificates

  • Jan_06 HydroCOM Actuator 25

    Flare line G 1/8

    Oil outlet G 3/8 female (old version: M14x1,5)

    Venting to ambient

    Leakage oil G 1/8

    Oil inlet female G1/2(old version: Parker 16S)

    HydroCOM Actuator Connections

    ATEX version:3 x M20x1.5

    Jan_06 HydroCOM Actuator 26

    HydroCOM Actuator Workshop testingAfter assembly

    Valve housing:2 hour leakage test at 150 bar

    Valve housing:High pressure dynamic test at 8000N:Criteria: 10mm travel of high pressure piston must take at least 4s

    Electric function test of complete actuator

    8000N

  • Jan_06 HydroCOM Actuator 27

    Spare Actuator Adoption

    Following parts must be in accordance with the partlist for the compressor and actuator the spare actuator is intended to be used:

    - Solex Nozzle (diameter)- Soft touch damper: length of throttle piston- Seal housing design / sealing materials- Is integrated oil pressure sensor required?- Correct bus address- Termination yes/no

    (must be set for last actuator on the bus)