1000310_eus教學(9)急診超音波在骨骼軟組織之應用
DESCRIPTION
Emergency Ultrasound (EUS)教學(9) 急診超音波在骨骼軟組織之應用新光醫院急診醫學科 陳國智醫師 中華民國醫用超音波學會指導醫師30M, abdominal pain for one weekOutlines• • • • • • US anatomic considerations Skin and soft tissue infection Foreign body localization Abdominal wall mass evaluation Bony fracture evaluation Imaging of tendons, joints, and muscles正常組織超音波影像• • • • • • • • Skin Subcutaneous tissue Fascial planes Muscles Tendon– Echogenic – Hypoechoic – Traverse by irregular strands of hyperechoic connective tissue – HyperechTRANSCRIPT
![Page 1: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/1.jpg)
Emergency Ultrasound (EUS)教學(9)
急診超音波在骨骼軟組織之應用
新光醫院急診醫學科
陳國智醫師
中華民國醫用超音波學會指導醫師
![Page 2: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/2.jpg)
30M, abdominal pain for one week
![Page 3: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/3.jpg)
Outlines
• US anatomic considerations
• Skin and soft tissue infection
• Foreign body localization
• Abdominal wall mass evaluation
• Bony fracture evaluation
• Imaging of tendons, joints, and muscles
![Page 4: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/4.jpg)
正常組織超音波影像 • Skin
– Echogenic
• Subcutaneous tissue – Hypoechoic
– Traverse by irregular strands of hyperechoic connective tissue
• Fascial planes – Hyperechoic; regular thickness
• Muscles – Striated appearance on long axis scan
• Tendon – Fibrillar; echogenic
• Vascular structures – Anechoic (Artery versus Vein)
• Lymph nodes – Irregular, circular, echogenic; with hypoechoic rim
• Bones – Echogenic cortices and dense acoustic shadows
![Page 5: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/5.jpg)
掃描注意事項
• 高解析線形探頭 (5-10MHz)為第一首選
• 注意深度(depth)和焦點(focus)的設定
• 適當應用探頭施壓
• 至少掃描兩個介面 (longitudinal & transverse)
• 考慮和對側比較 & 呈現在同一畫面 (Split screen)
• 如何改善掃描品質 – Stand-off pad
– Water/gel-filled glove
– Water bath technique
![Page 6: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/6.jpg)
Water/gel-filled glove
![Page 7: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/7.jpg)
皮膚 & 軟組織感染
![Page 8: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/8.jpg)
EUS在皮膚 & 軟組織感染的應用
• 須熟悉正常超音波軟組織影像
• 認識週遭組織及結構
• 協助設定最佳切除及引流路徑
• 正確診斷不明顯膿瘍
診斷
• 正確定位不明顯膿瘍
定位
• 協助膿瘍引流
處置
![Page 9: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/9.jpg)
皮膚 & 軟組織感染
• Cellulitis – Cobblestone-like appearance
• Subcutaneous abscess – Variable appearance
– Most: hypoechoic; spherical mass
– Content: • Hyperechoic sediment
• Septae
• Gas
• Isoechoic or hyperechoic
• Liquefied pus – induced motion of the
content
• Necrotizing fasciitis – Marked thickened of SC layer
– A layer of anechoic fluid, • greater than 4 mm
• adjacent to deep fascia
– Subcuatneous gas • Acoustic shadow
• Reverberation artifact
![Page 10: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/10.jpg)
Cellulitis
• Nonspecific
• Indicative of edema
• Skin
• Subcutaneous tissue
• Compare to unaffected side
![Page 11: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/11.jpg)
Normal v.s. Cellulitis
![Page 12: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/12.jpg)
Soft-tissue US changes cellulitis
management (56%, 71/126)
Tayal VS, et al. AEM. 2006;13:384-388
![Page 13: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/13.jpg)
EUS improves accuracy of superficial
abscess detection
Squire BT, et al. AEM. 2005;12:601-606
![Page 14: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/14.jpg)
Chest wall cellulitis & abscess
![Page 15: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/15.jpg)
70F, PN with chest wall abscess
![Page 16: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/16.jpg)
Dorsal foot cellulitis with clinically
unsuspected coexistent abscess
![Page 17: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/17.jpg)
Soft tissue with abscess
![Page 18: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/18.jpg)
Thigh abscess
(Lesion side v.s. Normal side)
![Page 19: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/19.jpg)
Soft tissue abscess
![Page 20: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/20.jpg)
Thigh abscess
![Page 21: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/21.jpg)
Subcutaneous abscess (Thigh)
![Page 22: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/22.jpg)
Buttock abscess
![Page 23: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/23.jpg)
Thigh cellulitis and abscess
![Page 24: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/24.jpg)
Antecubital fossa abscess
![Page 25: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/25.jpg)
Post-op abdominal wall abscess
![Page 26: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/26.jpg)
Gas-forming abscess
![Page 27: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/27.jpg)
L’t groin pulsatile mass
![Page 28: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/28.jpg)
NTUH experience
• diffuse thickening of the SC tissue
• a layer of fluid accumulation more than 4 mm in depth along the deep fascial layer
• 66 patients (17,NF)
• Sensitivity: 88.2%
• Specificity: 93.3%
• PPV: 83.3%
• NPV: 95.4%
• Accuarcy: 91.9
Yen ZS, et al. AEM. 2002;9:1448-1451
![Page 29: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/29.jpg)
72M, NF of left forearm
![Page 30: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/30.jpg)
Chronic Lymphedema
![Page 31: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/31.jpg)
Skin & Soft Tissue Infections
Clinical decision making
Cellulitis
No suspicion of abscess
Skin and soft tissue infection
Obvious abscess
Fluctuant or draining
Possible or suspected abscess
No fluctuance
I & D EUS Abx
Consider NSTI
Abscess seen No abscess seen Localize
collection
![Page 32: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/32.jpg)
Pitfalls
• Abscess are not always hypoechoic
• Failure to consider necrotizing soft tissue
infections
• Failure to recognize adjacent structures
![Page 33: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/33.jpg)
軟組織異物
![Page 34: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/34.jpg)
軟組織異物診斷及定位
• 殘留軟組織異物
–易使受傷的皮膚及軟組織產生併發症
–常不易由病史和理學檢查查覺
– 38% 在第一次就診時無法診斷出來
–為常見的醫療糾紛原因之一
![Page 35: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/35.jpg)
軟組織異物診斷及定位
臨床應用
• 協助診斷X-ray不易查覺異物 (radiolucent)
• 定位異物及辦識其特性及週遭結構
• 協助異物移除
![Page 36: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/36.jpg)
軟組織異物
• 常見異物 – glass, wood, metal, plastic, gravel
• 異物: – Size; material; retained period
– Hyperechoic
– Variable acoustic shadow
– Variable reverberation artifact
• 殘留異物超過24-48小時 – 因組織反應,會在異物周圍形成一圈 (hypoechoic halo)
![Page 37: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/37.jpg)
軟組織異物
移除技巧
• Ultrasound-guided incision
• Real-time ultrasound to guide placement
of forceps or a hemostat next to the FBs
(linear FB)
• Ultrasound-guided needle localization
![Page 38: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/38.jpg)
Normal thenar eminence
![Page 39: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/39.jpg)
Chicken thigh with stand-off pad
![Page 40: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/40.jpg)
Wooden toothpick
![Page 41: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/41.jpg)
Wooden FB
![Page 42: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/42.jpg)
Needle
![Page 43: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/43.jpg)
Broken needle fragment
![Page 44: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/44.jpg)
Chest wall bullet
![Page 45: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/45.jpg)
BB
![Page 46: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/46.jpg)
Linear glass shard
![Page 47: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/47.jpg)
Broken glass bottle
![Page 48: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/48.jpg)
Plastic toothpick
![Page 49: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/49.jpg)
Gravel
![Page 50: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/50.jpg)
Left thigh FB
![Page 51: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/51.jpg)
Case
Swollen digit
![Page 52: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/52.jpg)
Finger X-ray
![Page 53: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/53.jpg)
Wood fragment
![Page 54: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/54.jpg)
Time matters
![Page 55: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/55.jpg)
30M carpenter
Wood splinter
![Page 56: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/56.jpg)
Needle approaches FB
![Page 57: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/57.jpg)
Pitfalls
• Inadequate knowledge of the regional
sonographic anatomy
• Failure to take necessary steps to optimize
scanning of small superficial objects
• Other pitfall
• Foreign body removal
![Page 58: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/58.jpg)
骨折評估
![Page 59: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/59.jpg)
骨折評估
• 肋骨骨折
• 胸骨骨折
• 長骨骨折
• 堅困環境骨折
• 骨折復位
• 脫位復位
• FASTER
![Page 60: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/60.jpg)
骨折評估
• 骨表面產生不連續線條
• 骨折周圍低回音血腫
• 掃描時注意最痛點
• 至少進行兩個介面掃描
![Page 61: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/61.jpg)
Rib
![Page 62: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/62.jpg)
Normal rib
![Page 63: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/63.jpg)
Rib fracture
![Page 64: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/64.jpg)
Rib fracture
![Page 65: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/65.jpg)
Rib fracture
![Page 66: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/66.jpg)
Normal sternum
![Page 67: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/67.jpg)
Sternal body fracture
![Page 68: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/68.jpg)
Femur
![Page 69: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/69.jpg)
Femoral shaft fracture
![Page 70: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/70.jpg)
Tibial shaft fracture
![Page 71: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/71.jpg)
Pitfalls
• General pitfalls
• Rib pitfalls – Pseudofracture
– Misidentify pleura for a rib
• Sternum fracture pitfalls – Sternomanubrial junction
– Hypoechoic pectoralis muscle
• Long bone fracture pitfalls – Exellent for only midshaft fractures
![Page 72: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/72.jpg)
關節液評估
![Page 73: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/73.jpg)
Elbow effusion
(Olecranon fossa)
![Page 74: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/74.jpg)
Hip X-ray
Axis for imaging hip effusion
![Page 75: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/75.jpg)
Normal v.s. Hip effusion
![Page 76: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/76.jpg)
Septic arthritis of right hip
![Page 77: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/77.jpg)
Suprapatellar effusion
![Page 78: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/78.jpg)
US guided arthrocentesis
![Page 79: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/79.jpg)
Ankle sonogram
![Page 80: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/80.jpg)
肩關節復位評估
![Page 81: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/81.jpg)
Verify shoulder reduction
AJEM 2009
![Page 82: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/82.jpg)
40F, Should dislocation
& post-reduction
![Page 83: 1000310_EUS教學(9)急診超音波在骨骼軟組織之應用](https://reader034.vdocuments.pub/reader034/viewer/2022050906/5572082a497959fc0b8bc472/html5/thumbnails/83.jpg)
Take Home Message
• 急診超音波可協助骨骼軟組織之臨床診斷,及協助進行相關處置
• 第一首選為高頻線形探頭
• EUS對臨床診斷及決策有立即幫助的應用才是最需要學習的項目