    3EK7 Medium Voltage

    Silicone Insulated Surge Arresters

  • 8/14/2019 3ek7 Iec Ansi En

    2/12

    2

    The 3EK7 surge arrester from Siemens offers since 1999

    superior protection against power surges for the equip-

    ment in electrical distribution systems with operating

    voltages of up to 72.5 kV. Besides being highly resistant

    to environmental pollution of all kinds, its performance

    in dealing with earth faults and its excellent short-circuit

    ratings are setting entirely new standards. The silicone

    on the 3EK7 surge arrester refuses to allow any deposits

    of pollution or films of moisture to form on it. Thus,

    surface currents caused by pollution will virtually not

    occur. The 3EK7 arrester is also very lightweight,

    robust and durable, due to its special Cage Design.

    Setting Standards

    The 3EK7s mechanical

    features:

    Glass-collared MOV, Silicone rubber housing, FRP rods and Aluminium end fittings.

    Three types of 3EK7 surge

    arresters are available:

    3EK7-. C.. surge arrestersaccording to IEC 60099-4with metric thread,

    3EK7...-. A.. surge arrestersaccording to IEEE Std C 62.11with imperial thread.

    For special applications:

    3EK7...-. B.. surge arrestersaccording to IEEE Std C 62.11with metric thread.

  • 8/14/2019 3ek7 Iec Ansi En

    3/12

    3

    3EK7 Design

    3EK7 a top quality product

    The silicone rubber housing is molded directly onto

    the MOV blocks and the protection cage. It providesan excellent sealing system against moisture ingressand partial discharges. In addition, the MOV blocksare glass-collared to prevent aging.

    Highest quality materials. Silicone rubber is highlyhydrophobic and maintains this ability to repel waterand any deposits of pollution throughout its entireservice life. This results in high tracking and erosionresistance. Furthermore, the silicone rubber housingis self-extinguishing and flame-retardant. These advan-tages provide maintenance free and reliable servicelife for 3EK7 arresters.

    Manufacturing plants are certified under ISO 9001and ISO 14001.

    3EK7 arresters have been type tested by an indepen-dent test laboratory.

    Secure and reliable design

    The 3EK7 series is based on a cage of pre-stressed fiber-reinforced plastic rods for high mechanical strength,reducing the risk of internal components being ejected.In the extremely rare event of the resistors being over-loaded, arcing cannot result in a build-up of critical

    internal pressure, since the resistors are not enclosedin a sealed mechanical shell. Thus, the arc can escape

    through the silicone sheath, leaving the mechanicalsupport structure of the enclosure unharmed.

    The cage is lightweight design and yet it offers excel-lent torsional, tensile and cantilever strength: Maximumworking cantilever strength of 350 Nm.

    Silicone rubber is resistant to UV and ozone exposure aswell as to all common organic and non-organic solventsand cleaning agents. Therefore, the 3EK7 is suitable forany environmental conditions of industrial areas as wellas in desert or coastal regions.

    3EK7 arresters are suitable for a temperature rangefrom 55 C to +60 C.

    Application altitude up to 3600 m a.s.l.

    Fast delivery

    Flexibility in production and in our global networkof service and sales facilities provide fast and promptsupply.

    M12 or 3/8 inch stainless steel stud

    End fitting

    Silicone housing,

    directly molded

    Metal oxide varistor MOV

    FRP rods

    End fitting

    M12 or 3/8 inch stainless steel stud

    ClampNut, washer

    Nut, washer

    Glass coating

  • 8/14/2019 3ek7 Iec Ansi En

    4/12

    4

    Selection and Main Data

    3EK7 Arresters According to IEC 60099-4

    Table 1: IEC power-frequency voltage versus time characteristic

    Nominal dischargecurrent In

    10 kA

    Maximum continuousoperating voltage Uc

    48 kV

    Rated voltage Ur 60 kV

    Long-durationcurrent impulse

    325 A

    Rated short-circuit current 20 kA

    Low shor t-circuit current 600 A

    High-current impulse 100 kA

    Specified long-term loadSLL (Fstat)

    3 50 Nm

    Specified short-term load

    SSL (Fdyn)5 00 Nm

    Energy absorptioncapability (thermal)

    3.5 kJ/kV Ur

    Rated

    voltage

    Continuous

    operating

    voltage

    Arrester type Maximum values of the residual voltages

    at discharge currents of the following impulses

    Creep

    dista

    Ur[kV]

    Uc[kV]

    8/20 s1 kA[kV]

    8/20 s3 kA[kV]

    8/20 s5 kA[kV]

    8/20 s10 kA[kV]

    8/20 s20 kA[kV]

    30/60 s125 A[kV]

    30/60 s500 A[kV] [mm

    3 2.4 3EK7 030 - 4 C B 4 6.5 7.1 7.4 8.0 9.1 5.8 6.1 37

    5 4.0 3EK7 050 - 4 C B 4 10.9 11.8 12.3 13.3 15.2 9.7 10.2 37

    6 4.8 3EK7 060 - 4 C B 4 13.0 14.2 14.8 15.9 18.3 11.6 12.2 37

    9 7.2 3EK7 090 - 4 C B 4 19.6 21.2 22.2 23.9 27.4 17.4 18.4 37

    12 9.6 3EK7 120 - 4 C C 4 26.1 28.3 29.6 31.8 36.6 23.2 24.5 48

    15 12.0 3EK7 150 - 4 C C 4 32.6 35.4 37.0 39.8 45.7 29.0 30.6 48

    18 14.4 3EK7 180 - 4 C D 4 39.1 42.5 44.4 47.7 54.9 34.8 36.7 60

    21 16.8 3EK7 210 - 4 C D 4 45.6 49.5 51.8 55.7 64.0 40.6 42.9 60

    24 19.2 3EK7 240 - 4 C E 4 52.2 56.6 59.1 63.6 73.1 46.4 49.0 77

    27 21.6 3EK7 270 - 4 C E 4 58.7 63.7 66.5 71.6 82.3 52.2 55.1 77

    30 24.0 3EK7 300 - 4 C F 4 65.2 70.8 73.9 79.5 91.4 58.0 61.2 90

    33 26.4 3EK7 330 - 4 C H 4 71.7 77.8 81.3 87.5 101 63.8 67.3 123

    36 28.8 3EK7 360 - 4 C H 4 78.2 84.9 88.7 95.4 110 69.6 73.5 12339 31.2 3EK7 390 - 4 C H 4 84.7 92.0 96.1 103 119 75.4 79.6 123

    42 33.6 3EK7 420 - 4 C H 4 91.3 99.1 104 111 128 81.2 85.7 123

    45 36.0 3EK7 450 - 4 C H 4 97.8 106 111 119 137 87.1 91.8 123

    48 38.4 3EK7 480 - 4 C H 4 104 113 118 127 146 92.9 97.9 123

    51 40.8 3EK7 510 - 4 C J 4 111 120 126 135 155 98.7 104 142

    54 43.2 3EK7 540 - 4 C J 4 117 127 133 143 165 104 110 142

    57 45.6 3EK7 570 - 4 C J 4 124 134 140 151 174 110 116 142

    60 48.0 3EK7 600 - 4 C J 4 130 142 148 159 183 116 122 142

    60 48.0 3EK7 600 - 4 C K 4 130 142 148 159 183 116 122 159

    Table 2: 3EK7 arrester main data

    Table 4: 3EK7 nominal discharge current 10 kA

    Voltage per unit Ur

    1.15

    1.1

    1.05

    1.0

    0.95

    0.9

    0.85

    0.1 1 10

    1.2

    0.8

    Time inseconds

    Preheating to 60C and stressed with

    one high current impulse prior to TOV

    100 1000

  • 8/14/2019 3ek7 Iec Ansi En

    5/12

    5

    Highest voltage

    for equipment

    Um

    [kV]

    Rated lightning

    impulse withstand

    voltage

    [kV]

    Solidly earthed

    neutral system

    Isolated

    neutral system

    Impedance earthed

    neutral system

    Resonant earthed

    neutral system

    2.75 30; 45; 60 3EK7 030-.C.. 3EK7 050-.C.. 3EK7 030-.C.. 3EK7 050-.C..

    3.6 20; 40 3EK7 030-.C.. 3EK7 050-.C.. 3EK7 030-.C.. 3EK7 050-.C..

    5.5 45; 60; 75 3EK7 050-.C.. 3EK7 090-.C.. 3EK7 050-.C.. 3EK7 090-.C..

    7.2 40; 60 3EK7 060-.C.. 3EK7 090-.C.. 3EK7 090-.C.. 3EK7 090-.C..

    8.25 60; 75; 95 3EK7 090-.C.. 3EK7 105-.C.. 3EK7 090-.C.. 3EK7 105-.C..

    12 60; 75; 95 3EK7 090-.C.. 3EK7 150-.C.. 3EK7 105-.C.. 3EK7 150-.C..

    15.5 85; 110 3EK7 120-.C.. 3EK7 210-.C.. 3EK7 150-.C.. 3EK7 210-.C..

    17.5 95 3EK7 150-.C.. 3EK7 220-.C.. 3EK7 150-.C.. 3EK7 220-.C..

    24 125; 145 3EK7 180-.C.. 3EK7 300-.C.. 3EK7 210-.C.. 3EK7 300-.C..

    25 125; 145 3EK7 210-.C.. 3EK7 330-.C.. 3EK7 220-.C.. 3EK7 330-.C..

    27 150 3EK7 210-.C.. 3EK7 360-.C.. 3EK7 240-.C.. 3EK7 360-.C..

    30 160 3EK7 240-.C.. 3EK7 390-.C.. 3EK7 270-.C.. 3EK7 390-.C..

    36 170 3EK7 270-.C.. 3EK7 450-.C.. 3EK7 330-.C.. 3EK7 450-.C..

    38 200 3EK7 300-.C.. 3EK7 480-.C.. 3EK7 330-.C.. 3EK7 480-.C..

    40.5 190 3EK7 330-.C.. 3EK7 510-.C.. 3EK7 360-.C.. 3EK7 510-.C..48.3 250 3EK7 390-.C.. 3EK7 600-.C.. 3EK7 420-.C.. 3EK7 600-.C..

    52 250 3EK7 420-.C.. 3EK7 450-.C..

    72.5 325 3EK7 570-.C..

    over

    ance

    Housing

    insulation

    Specified

    short-term

    load SSL (Fdyn)

    Specified

    long-term

    load SLL (Fstat)

    Height

    H 1)Weight

    m]

    Lightning impulse

    withstand voltage1.2/50 s

    [kV]

    Power frequency

    withstand voltage1 min., wet

    [kV] [N] [N] [mm] [kg]

    80 104 49 2940 2050 170 1.5

    80 104 49 2940 2050 170 1.5

    80 104 49 2940 2050 170 1.6

    80 104 49 2940 2050 170 1.6

    0 122 57 2500 1750 200 1.9

    0 122 57 2500 1750 200 2.0

    48 144 67 2080 1450 240 2.3

    48 144 67 2080 1450 240 2.4

    86 166 77 1850 1290 270 2.7

    86 166 77 1850 1290 270 2.8

    8 184 86 1660 1160 300 3.1

    8 242 113 1250 870 400 3.9

    8 242 113 1250 870 400 4.08 242 113 1250 870 400 4.1

    8 242 113 1250 870 400 4.1

    8 242 113 1250 870 400 4.2

    8 242 113 1250 870 400 4.3

    84 281 131 1060 740 470 4.9

    84 281 131 1060 740 470 5.0

    84 281 131 1060 740 470 5.0

    84 281 131 1060 740 470 5.1

    20 302 140 980 680 510 5.3

    Table 3: Typical 3EK7 arresters for system voltages according to IEC 60099-4

    1) Refer to figure 1 on page 8

  • 8/14/2019 3ek7 Iec Ansi En

    6/12

    6

    Selection and Main Data

    3EK7 Arresters According to IEEE Std C 62.11

    Table 5: ANSI temporary overvoltage

    H eavy duty Riser pole

    Maximum continuousoperating voltage

    MCOV

    29 kV 29 kV

    Duty-cycle voltage 36 kV 36 kV

    Short-circuit current0.2 s

    20 kA 20 kA

    Low-current,long-duration

    250 A 250 A

    Low-currentpressure relief

    600 A 600 A

    High-current,short-duration

    100 kA 100 kA

    Lightning impulseclassifying current

    10 kA 10 kA

    Energy absorptioncapability (thermal)

    4.6 kJ/kVMCOV 4.6 kJ/kVMCOV

    Maximum design

    cantilever load-static(MDCL)2478 inch-lbf 2478 inch-lbf

    Table 6: 3EK7 distribution arrester main data

    3EK7 heavy duty

    Duty-cycle

    voltageMCOV

    TOV Capability

    w/o dutyArrester part number Protective Level Maximum discharge voltage

    [kV] [kV]for 0.1s

    [kV]FOW

    [kV] cr

    8/20 s1.5 kA[kV] cr

    8/20 s3 kA

    [kV] cr

    8/20 s5 kA

    [kV] cr

    8/20 s10 kA[kV] cr

    8/20 s20 kA[kV] cr

    8/20 s40 kA[kV] cr

    45/912[kV

    3 2.55 4.3 3EK7 030 - 3 A B 4 10.5 8.1 8.5 8.8 9.5 10.9 12.6 6

    6 5.10 8.5 3EK7 060 - 3 A B 4 21.6 16.7 17.4 18.2 19.6 22.5 26.1 149 7.65 12.8 3EK7 090 - 3 A B 4 30.9 23.9 25.0 26.1 28.1 32.3 37.4 20

    10 8.40 14.0 3EK7 100 - 3 A B 4 32.3 25.0 26.2 27.3 29.4 33.8 39.1 21

    12 10.2 17.0 3EK7 120 - 3 A C 4 41.0 31.7 33.2 34.7 37.3 42.9 49.6 27

    15 12.7 21.2 3EK7 150 - 3 A D 4 51.3 39.6 41.5 43.3 46.6 53.6 62.0 34

    18 15.3 25.6 3EK7 180 - 3 A D 4 61.5 47.5 49.8 52.0 55.9 64.3 74.3 40

    21 17.0 28.4 3EK7 210 - 3 A E 4 67.3 52.0 54.5 56.9 61.2 70.4 81.4 44

    24 19.5 32.6 3EK7 240 - 3 A F 4 77.6 59.9 62.7 65.6 70.5 81.1 93.8 51

    27 22.0 36.7 3EK7 270 - 3 A F 4 87.7 67.7 70.9 74.1 79.7 91.7 106 58

    30 24.4 40.7 3EK7 300 - 3 A H 4 96.6 74.6 78.1 81.7 87.8 101 117 64

    33 27.5 45.9 3EK7 330 - 3 A H 4 108 83.6 87.6 91.5 98.4 113 131 71

    36 29.0 48.4 3EK7 360 - 3 A H 4 119 92 96 100 108 124 144 78

    3EK7 riser pole

    Duty-cycle

    voltageMCOV

    TOV Capability

    w/o dutyArrester part number Protective Level Maximum discharge voltage

    [kV] [kV]for 0.1s

    [kV]FOW

    [kV] cr

    8/20 s1.5 kA[kV] cr

    8/20 s3 kA

    [kV] cr

    8/20 s5 kA

    [kV] cr

    8/20 s10 kA[kV] cr

    8/20 s20 kA[kV] cr

    8/20 s40 kA[kV] cr

    45/912[kV

    3 2.55 3.8 3EK7 030 - 4 A B 4 8.9 6.8 7.1 7.4 8.0 9.2 10.6 5

    6 5.10 7.6 3EK7 060 - 4 A B 4 17.7 13.6 14.2 14.8 15.9 18.3 21.2 11

    9 7.65 11.4 3EK7 090 - 4 A B 4 26.4 20.3 21.3 22.2 23.9 27.5 31.8 17

    10 8.40 12.5 3EK7 100 - 4 A C 4 29.3 22.6 23.7 24.7 26.6 30.6 35.4 19

    12 10.2 15.1 3EK7 120 - 4 A D 4 35.2 27.1 28.4 29.7 31.9 36.7 42.4 23

    15 12.7 18.9 3EK7 150 - 4 A D 4 43.9 33.9 35.5 37.1 39.9 45.9 53.0 29

    18 15.3 22.7 3EK7 180 - 4 A E 4 52.7 40.7 42.6 44.5 47.8 55.0 63.6 34

    21 17.0 25.2 3EK7 210 - 4 A F 4 61.5 47.4 49.7 51.9 55.8 64.2 74.2 40

    24 19.5 29.0 3EK7 240 - 4 A H 4 70.2 54.2 56.8 59.3 63.8 73.4 84.8 46

    27 22.0 32.7 3EK7 270 - 4 A H 4 79.1 61.0 63.9 66.7 71.8 82.5 95.4 52

    30 24.4 36.2 3EK7 300 - 4 A H 4 87.7 67.8 71.0 74.2 79.7 91.7 106 58

    33 27.5 40.8 3EK7 330 - 4 A J 4 96.6 74.6 78.1 81.6 87.7 101 117 64

    36 29.0 43.1 3EK7 360 - 4 A K 4 105 81.3 85.2 89.0 95.7 110 127 69

    Voltage per unit MCOV

    1.7

    1.6

    1.5

    1.4

    1.3

    1.2

    1.1

    0.01 0.1 1 10

    1.8

    1.0

    Time inseconds

    Preheating to 140F/60C

    no prior duty heavy duty riser pole

    100 1000 10000

  • 8/14/2019 3ek7 Iec Ansi En

    7/12

  • 8/14/2019 3ek7 Iec Ansi En

    8/12

    8

    Drawings and Accessories

    Figure 4: DIN insulating bracket for Ur 15 kVOrder code P22; 0.85 kg

    Figure 5: DIN insulating bracket for Ur 36 kVOrder code P22; 1.0 kg

    Figure 2: NEMA insulating bracket for Ur 15 kVOrder code P12; 0.35 kg

    Figure 3: NEMA insulating bracket for Ur 36 kVOrder code P12; 0.5 kg

    Figure 1: 3EK7 surge arrester main dimensions* please see tables on page 5 or 7

    104

    104

    156

    197

    12 12

    15

    17

    26

    60

    54

    8 8

    200

    15

    14

    .5

    14

    .5

    17

    26

    60

    54

    241

    M12

    M12

    36

    36

    H

    *

    64

    41

    38.5

    108

    154

    20

    104

    31

    .5

    94

    14

    .2

    18

    .2

    74

    12.5

    14

    64

    41

    38.5

    152

    198

    20

    104

    31

    .5 1

    4.2

    74

    18

    .2

    94

    12.5

    14

  • 8/14/2019 3ek7 Iec Ansi En

    9/12

    9

    Figure 8: L-bracketOrder code M12; 0.1 kg

    Figure 9: DIN metal bracket (hot dip galvanised)Order code P21; 0.6 kg

    Figure 10: Insulated ground lead/Insulated line leadOrder code R51; 0.09 kg, 16 mm2

    Figure 11: NEMA metal bracket (hot dip galvanized)Order code P11; 0.6 kg

    Figure 12: Transformer bracket 8.7"Order code Q11; 0.6 kg

    Figure 13:Transformer bracket 11"Order code Q12; 0.7 kg

    Figure 7: Bird protection capOrder code M81; 50 g

    Figure 6: DisconnectorOrder code P31; 0.1 kg

    SW14(width across flats 9/16")

    M12 or 3/8"

    21

    .5

    14 or 10.2 14

    25

    50

    152202

    14

    18

    78

    25

    178280 (11")

    41 64

    57

    14

    .3

    20

    434320 40

    13 1

    3

    450

    145 14

    221 (8.7")

    18

    78

    2541 64

    57

    14

    .3

    20

    434320

    40

    13

    16

    75

    20

    40

    13

    13

    33

    14

    8

    14

    .512

    26

    30

    60

    15197

    152

    30

    15

    24

    .5

    75

    57

  • 8/14/2019 3ek7 Iec Ansi En

    10/12

    10

    Drawings and Accessories

    Figure 14: Transformer bracket 12.25"Order code Q13; 0.8 kg

    Figure 15:Transformer bracket 14.5"Order code Q14; 0.8 kg

    Figure 16: NEMA X-arm bracketOrder code Q51; 1.3 kg

    Figure 18: Line clampOrder code M11 or M13; 0.1 kg

    Figure 19: Stainless steel capOrder code M71; 5 g

    Figure 17: Mounting plate, 37 mm heightOrder code Q81; 1.6 kg

    220

    198

    10

    .5

    150

    730120

    178

    310 (12.25")

    18

    78

    25

    14

    41 63

    57

    14

    .3

    434320

    40

    327368 (14.5")

    18

    76

    35

    14

    46

    69

    14

    .3

    19

    40

    86 64 86

    54

    55 40 40 55

    254

    14

    227

    200

    142

    253.5

    3x1

    20

    cable 8 14

    cable 14 18

    66

    71

    18

    1815

    .2

    12

    .5

    4

    45

    M13M11

    8 18

    86

    8 18

    92

  • 8/14/2019 3ek7 Iec Ansi En

    11/12

    11

    Order information

    Figure 22: 3EK7 surge arresterwith accessories P12, P31, P52 and Q11

    Figure 20: 3EK7 surge arrester withaccessories P12 and P31

    Figure 21: 3EK7 surge arrester withaccessories P12, P31 and Q51

    Part number 3 E K 7 300 4 C F 4 Z R51 M81 P12 P31

    Medium voltage surge arrester 3 E K 7

    Rated voltage in kV x 10 300

    Classification

    Distribution class, heavy duty (IEEE) 3

    Nominal discharge current In= 10 kA (IEC)

    or distribution class, riser pole (IEEE)4

    Standard

    IEEE Std C 62.11 with imperial-thread terminals A

    IEEE Std C 62.11 with metric-thread terminals B

    IEC - 60099-4 with metric-thread terminals C

    Housing size, creepage distance

    170 mm B

    200 mm C

    240 mm D

    270 mm E300 mm F

    400 mm H

    470 mm J

    510 mm K

    Form of sheds

    Alternating sheds 4

    Accessories* Z

    High-voltage terminal equipped with

    Line clamp M11 M11

    L-bracket M12

    Line clamp M13 M13

    Line lead, insulated, 455 mm/18 inch, 16 mm2 R51

    Stainless steel cap M71

    Bird protection cap M81

    Earth terminal equipped with

    NEMA metal bracket (hot dip galvanized steel) P11

    NEMA insulating bracket P12

    DIN metal bracket (hot dip galvanized steel) P21

    DIN insulating bracket P22

    Disconnector P31

    Ground strap, 245 mm P52

    Ground lead, insulated, 455 mm/18 inch, 16 mm2 R51

    Mounting auxiliaries

    Transformer bracket (8.7 inch) Q11

    Transformer bracket (11 inch) Q12

    Transformer bracket (12.25 inch) Q13

    Transformer bracket (14.5 inch) Q14

    X-arm bracket Q51

    Mounting plate for 200 mm and 10 inch bolt circle Q81

    *Other additional parts on request, not all combinations are possible

    Standard accessories at

    high-voltage terminal: M12 or 3/8 inch stud, standard clamp,washer and nut

    earthing terminal: M12 or 3/8 inch stud, washer and nut

    Outline drawings for common design

    options are shown in figure 20, 21 and 22

  • 8/14/2019 3ek7 Iec Ansi En

    12/12

    Published by and copyright 2011:

    Siemens AGEnergy SectorFreyeslebenstrasse 191058 Erlangen, Germany

    Siemens AG

    Energy SectorPower Transmission DivisionHigh Voltage ProductsNonnendammallee 10413629 Berlin, Germany

    www.siemens.com/energy/arrester

    Please contact us at:Phone: +49 30 386 33 222Fax: +49 30 386 26 721E-mail: [email protected]

    Power Transmission DivisionOrder No. E50001-G630-A110-V2-4A00 | Printed in Germany |Dispo 30002 | c4bs No. 7457 |TH 263-110140 | W | 472573 | WS | 11111.0

    Printed on elementary chlorine-free bleached paper.

    All rights reserved.

    Trademarks mentioned in this documentare the property of Siemens AG, its affiliates,or their respective owners.

    Subject to change without prior notice.The information in this document contains generaldescriptions of the technical options available, whichmay not apply in all cases. The required technicaloptions should therefore be specified in the contract.