aluminum plate-fin heat exchanger
DESCRIPTION
high ef. exchangerTRANSCRIPT
11/28/2015 Aluminum plate-fin heat exchanger - 杭州中泰深冷技术股份有限公司
http://www.zhongtaihangzhou.com/en/products_info.php?14 1/2
Zhongtai Group 中文 English
Packaged Unit
Cold box
Plate-fin heat exchanger
Your Position: Home Products and Services Product Category
Aluminum plate-fin heat exchanger
Aluminum plate-fin heat exchanger is a kind of high efficiency, compact and cryogenic heat exchanging equipment, with
characteristics of complicated design theory, high fin molding precision and brazed to be a whole piece at one time,
especially applicable to the cases of multi-stream or state changes during heat transfer.
Most brazed aluminum plate-fin heat exchangers have been installed in process plants used to separate a feed gas into its
constituents, for example by the partial liquefaction of the feed and subsequent distillation and separation. The products and
waste streams are then re-warmed against the feed streams. Condensers and reboilers are associated with distillation
columns. Often chillers using standard refrigerants are used. Brazed aluminum plate-fin heat exchangers are well suited for
these and many other services.
The major applications of brazed aluminum plate-fin heat exchangers have been in the cryogenic separation and liquefaction
of air (ASU); Natural Gas Processing (NGP) and Liquefaction (LNG); the production of petrochemicals and treatment of
offgases; large refrigeration systems.
The maximum working pressure for brazed aluminum plate-fin heat exchangers can be over 100 bar g while also having a
natural ability to accommodate a full vacuum design condition. Manufacturer dimensional constrains and thicker
components are required at high pressures, however. It is possible to have over twelve process streams, at various
pressures from minimum to maximum, in a single heat exchanger.
The maximum temperature rating is typically specified at 65°C. An upper limit of 65°C is suitable for most applications, and it
HOME ABOUT US PRODUCTS AND SERVICES HUMAN RESOURCES CONTACT US
11/28/2015 Aluminum plate-fin heat exchanger - 杭州中泰深冷技术股份有限公司
http://www.zhongtaihangzhou.com/en/products_info.php?14 2/2
[Back]
allows manufacturers to use 5083 aluminum alloy piping which is more economical. However, designs are available for up
to +204°C at lower pressures, and design temperatures in excess of 65°C are common. The minimum design temperature
is -269°C. See Chapter 6 for a full material listing.
In general, fluids should be clean, dry, and non-corrosive to aluminum. Trace impurities of H 2S, NH3, CO2, SO2, NO2, CO, Cl
and other acid-forming gases do not create corrosion problem in streams with water dew point temperatures lower than the
cold-end temperature of the brazed aluminum plate-fin heat exchanger. Under specific conditions, mercury can corrode
aluminum and therefore caution must be used when handling mercury-containing fluids.
Proper filters (usually mesh filters) must be installed upstream of the heat exchanger system and maintained according to
the filter manufacturers’ recommendations to prevent plugging from particulates such as pipe scale or molecular sieve dust.
If a brazed aluminum plate-fin heat exchanger is accidentally plugged, proven cleaning procedures are available.
Fluids containing compressor lube oils, and other heavy hydrocarbons are acceptable provided these contaminants do not
precipitate out on the fin surface. In the event of heavy fouling, chemical solvent cleaning of the exchanger is a proven method
of cleaning.
Most governing jurisdictions require a pressure test of the piping system after a heat exchanger is installed. The test shall
meet the requirements of the relevant code authority. It is highly recommended that a pressure test is NOT conducted with
water as the test medium. Water removal after the heat exchanger is installed is difficult and residual water trapped within the
heat exchanger can freeze during unit operation causing serious damage and lead to premature failure of the heat
exchanger. Each stream of the heat exchanger system must be tested individually, with the other streams unpressurized.
Oxygen-free nitrogen of dew point -40°C or better should be used as the test medium.
Zhongtai is at the forefront of industry for plate-fin heat exchanger design and manufacture, especially for high pressure,
phase transition and multi-stream cores. Zhongtai’s design always brings customers a minimum total investment for plate-
fin heat exchanger. At the moment, the highest design pressure of Zhongtai’s plate-fin heat exchanger is 9.28MPa, the
biggest single core size is 1.3*1.2*8.5m and main heat exchangers are applied for the biggest ASU 6 trains of
820,000Nm3/h. Zhongtai’s plate-fin heat exchangers, based on ASME code and PED, have been exported to 16 countries
including USA, Russia, Europe and India, etc.
Next
Customer Service Hotline:(86)571-63415978 Links