8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 1/35

Instructions shown in thefollowing sequence are completed

using the rotary instrument in the

Captek/Brasseler Crown and

Bridge kit.

Purchase of this kit is not

required yet may be

helpful. Call your 

laboratory, Captek or 

Brasseler representative

for additional questions

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 2/35

One of the many benefits of Captek crowns and bridges is the

versatility that the dentist has when choosing a preparation stylethat is comfortable for him/her and appropriate for the tooth being

treated and the desired esthetic outcome of the case.

The following sequence shows a variety of margin

designs along with the possible Captek copings that

can be fabricated on each design.

A deep Chamfer(Shoulder), Modified chamfer, and a

Shoulder-Bevel will be shown.

tm

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 3/35

Captek can be cemented with the

doctors cement of choice. Proper development of resistance and

retention form is still important to

follow. Excellent research on

resistance and retention form is

available upon request through your dental laboratory or Captek.

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 4/35

Modified Chamfer 

A basic Chamfer is astandard margin edge

design that can be

utilized for Captek 

crowns where the

metal can be brought

to the edge or,

if the exit angle of 

the margin is cut to a

90 degree angle, a porcelain margin

can be prescribed.

Chamfer/Shoulder 

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 5/35

After breaking contact and facial depth cuts

with 169L, The 5856 016 Super course is usedfor gross reduction. Initial reduction is ended

at or above tissue height. The depth cuts can

also be accomplished with the 5856 016 blk.

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 6/35

Final Finishing of 

Chamfer/Shoulder is

accomplished by placing a cordand prepping to the cord with

856 016 med.

Captek Crown with or 

without a Porcelain margin

could be placed right at the

tissue or .5 to 1 mm below predictable tissue post-

 preparation height.

1.

2.

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 7/35

With any margin design, proper consideration should be given to

 biological width, tissue type, esthetic

desires, retentive form and occlusalconsiderations.

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 8/35

Modified Chamfer Margin: Gross

reduction with the 5856 016 Super Course. The final

margin design can be accomplished with the 878K 

016 med. Shown below.

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 9/35

A thin cord is placed. Margin is then finalized and

refined with the 878K 016 med.

With a Modified Chamfer margin, the Captek metal should

extend to the edge and be covered with porcelain or left as an

exposed Captek collar. Margin placement should be .5 to

1mm subgingival when collar needs to be invisible to

 patient.

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 10/35

With any margin design, reduction for anterior teeth is

necessary on three planes on the labial surface. Proper 

facial reduction will result in attaining the full esthetic potential of Captek crowns and bridges.

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 11/35

Beveled shoulder prep…

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 12/35

Gross reduction is done and shoulder is placed to the tissue height

with 5856 016 SC.

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 13/35

Cord is placed and bevel is place sub gingival using 30006 60 016 med.

Beveled margin is ideal when using a small Captek exposed collar. Not ideal

when extending porcelain to the margin edge.

Due to the healthy tissue condition surrounding Captek restorations,

 practitioners are less hesitant to place small metal bands on Captek 

crowns even in the anterior. Bands or collars need to be place

appropriately in the sulcus so as to be invisible to patient.

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 14/35

Shoulder 

Modified Chamfer 

Beveled edge

All acceptable margin designs with Captek 

Knife edge, not shown, is also an acceptable margin design

for Captek restorations. Consult with your Captek Lab for 

further information and opinions.

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 15/35

Porcelain Margin

or metal to edge

is possible

Captek metal to edge

Metal collar necessary

Captek coping possibilities with each margin design

Metal to the edge with a metal band or covered with porcelain

is possible with Knife edge.

Shoulder Modified Chamfer 

Beveled edge

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 16/35

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 17/35

Case Review

With Dr. John Cranham

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 18/35

Post operative picture. Treatment plan required placement

of full coverage restorations from tooth numbers 5-13 and

21-28

Captek crowns were chosen as restoration of choice

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 19/35

Occlusion should be

evaluated prior to

  preparation. 1.5mmminimum of occlusal

clearance is necessary for 

all PFM restorations with

full porcelain coverage

including Captek.

Rotation of teeth to be

 prepared should be

noted. Rotated or tilted teeth must be

 prepared accordingly

if alignment change is

desired.

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 20/35

Proximal slices with the

169L carbide are

accomplished quicklyand safely. The 169L

will help eliminate over 

tapering of the final

 preparation

Incisal reduction of 2mm

is necessary. The 330mw

carbide could be used as

a depth cutting guide.

The cutting length of the

330mw is 2.2mm.

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 21/35

The 5856 016 blk (super course)

can be used for depth cuts

Anterior reduction usually is

necessary in 3 distinct planes.

5856 016 blk dimensions:1.6 mm

1.25mm

1.5mm buccal reduction inthe facial incisal tapering to

.8 mm reduction at the

gingival can provide predictable results with

Captek crown and/bridges.

Consult your certified Captek 

lab for their input and

opinion.

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 22/35

Depth cuts complete

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 23/35

Depth cuts (discussion)

In the posterior preparation sequence, Dr. Cranham

showed depth cuts with the 169L. The 169L is .9mm

wide. Taken to full depth, this guide, when gross

reduction is completed, should produce minimum

reduction of 1mm buccally and lingually. This is a very

conservative preparation depth and may be helpful in

situations where minimal reduction is the only option.

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 24/35

Gross reduction is finished with the 5856 blk.

Smoothing is accomplished with medium grit rotary

instruments.

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 25/35

Lingual margin reduction

can be accomplished

with a variety of rotaryinstrument shapes.

Medium or fine course

diamonds are necessaryto achieve proper 

smoothness.

Lingual reduction of 1.5mm is important for 

 proper material thickness

and for the technician todevelop proper 

functionality to the desired

restoration. It is also

required for maximumrestoration strength.

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 26/35

With any margin design, proper 

consideration should be given to

 biological width, tissue type, estheticdesires, retentive form and occlusion.

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 27/35

Retraction can be done with the restoring doctors

method of choice. Effective retraction will help define

margin placement, and impression accuracy.

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 28/35

Preparation finished

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 29/35

occlusal registrations

completed.

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 30/35

Temporization

Before

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 31/35

1 week post cementation

Before

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 32/35

Before After  

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 33/35

3 weeks post placement

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 34/35

8/3/2019 Anterior Captek

http://slidepdf.com/reader/full/anterior-captek 35/35

Captek is an every day choice for Esthetic, Versatile,Strong, plaque resistant crowns and bridges.