Page 1: Bezpečnosť kritickej infraštruktúry bez kompromisov! · Deep SCADA Understanding Unintrusive Passive Monitoring … our Answer is an Active Integration between SCADAguardian and

© Copyright Fortinet Inc. All rights reserved.

Bezpečnosť kritickej infraštruktúry bez kompromisov!Ako ochrániť Vašu ICS sieť s Fortinet Security Fabric-omPeter Kocik, Systems Engineer, CEE

Page 2: Bezpečnosť kritickej infraštruktúry bez kompromisov! · Deep SCADA Understanding Unintrusive Passive Monitoring … our Answer is an Active Integration between SCADAguardian and

2

Convergence of Information and Operational Technology

What was Air Gapped and Proprietary is Now Connected and General Purpose

In the past, OT was … Now OT is …§ Isolated from IT§ Run on proprietary control protocols§ Run on specialized hardware§ Run on proprietary embedded operating systems§ Connected by copper and twisted pair

§ Bridged into corporate networks§ Riding common internet protocols§ Run on general purpose hardware with IT origins§ Running mainstream IT operating systems§ Increasingly connected via standard wireless technologies

Page 3: Bezpečnosť kritickej infraštruktúry bez kompromisov! · Deep SCADA Understanding Unintrusive Passive Monitoring … our Answer is an Active Integration between SCADAguardian and

3

Breach points everywhere

§ Outside threat: Black Hat§ Inside threat: Hard Hat§ Air gap breached§ RTU or HMI exploits§ DOS attack of Protocols§ Droppers USB

Corporate LAN

Domain Controller

Business Systems

Air gap breached in multiple locations allowing threats to propogate

Supervisory Control System and associated databases

Human Machine Interface (HMI)

Remote Terminal Unit

Sensors

Pressure

Pump/fan speed

Noise Level

Oil levels and Maintenance alarms

Radioactivity levels

Water levels

Temperature

Flow Rate

RTU security compromised and SCADA system vulnerable to DoSand malicious control

Remote Terminal Unit

Page 4: Bezpečnosť kritickej infraštruktúry bez kompromisov! · Deep SCADA Understanding Unintrusive Passive Monitoring … our Answer is an Active Integration between SCADAguardian and

4

Fortinet Security Fabric for IT/OT Convergence Corporate LAN

Domain Controller

Business Systems

Supervisory Control System and associated databases

Human Machine Interface (HMI)

Remote Terminal Unit

Sensors

Pressure

Pump/fan speed

Noise Level

Oil levels and Maintenance alarms

Radioactivity levels

Water levels

Temperature

Flow Rate

Prevent threats from entering with NGFW (FortiGate), Secure Email Gateway (FortiMail) and Sandbox (FortiSandbox)

Page 5: Bezpečnosť kritickej infraštruktúry bez kompromisov! · Deep SCADA Understanding Unintrusive Passive Monitoring … our Answer is an Active Integration between SCADAguardian and

5

Fortinet Security Fabric for IT/OT Convergence Corporate LAN

Domain Controller

Business Systems

Supervisory Control System and associated databases

Human Machine Interface (HMI)

Remote Terminal Unit

Sensors

Pressure

Pump/fan speed

Noise Level

Oil levels and Maintenance alarms

Radioactivity levels

Water levels

Temperature

Flow Rate

Segregate networks, prevent malware (FortiGate) and control access (FortiAuthenticator)

Page 6: Bezpečnosť kritickej infraštruktúry bez kompromisov! · Deep SCADA Understanding Unintrusive Passive Monitoring … our Answer is an Active Integration between SCADAguardian and

6

Fortinet Security Fabric for IT/OT Convergence Corporate LAN

Domain Controller

Business Systems

Supervisory Control System and associated databases

Human Machine Interface (HMI)

Remote Terminal Unit

Sensors

Pressure

Pump/fan speed

Noise Level

Oil levels and Maintenance alarms

Radioactivity levels

Water levels

Temperature

Flow Rate

Secure SCADA communications with hardware accelerated VPN back to the Management HMI network (FortiGate)

Page 7: Bezpečnosť kritickej infraštruktúry bez kompromisov! · Deep SCADA Understanding Unintrusive Passive Monitoring … our Answer is an Active Integration between SCADAguardian and

7

Fortinet Security Fabric for IT/OT Convergence Corporate LAN

Domain Controller

Business Systems

Supervisory Control System and associated databases

Human Machine Interface (HMI)

Remote Terminal Unit

Sensors

Pressure

Pump/fan speed

Noise Level

Oil levels and Maintenance alarms

Radioactivity levels

Water levels

Temperature

Flow Rate

Prevent malware propagation and non-authorized communication channels (FortiGate)

Page 8: Bezpečnosť kritickej infraštruktúry bez kompromisov! · Deep SCADA Understanding Unintrusive Passive Monitoring … our Answer is an Active Integration between SCADAguardian and

8

Fortinet Security Fabric Strategy Corporate LAN

Domain Controller

Business Systems

Supervisory Control System and associated databases

Human Machine Interface (HMI)

Remote Terminal Unit

Sensors

Pressure

Pump/fan speed

Noise Level

Oil levels and Maintenance alarms

Radioactivity levels

Water levels

Temperature

Flow Rate

Protect web based HMI from exploitation with Web Application Firewalling (FortiWeb)

Page 9: Bezpečnosť kritickej infraštruktúry bez kompromisov! · Deep SCADA Understanding Unintrusive Passive Monitoring … our Answer is an Active Integration between SCADAguardian and

9

Fortinet Security Fabric for IT/OT Convergence Corporate LAN

Domain Controller

Business Systems

Supervisory Control System and associated databases

Human Machine Interface (HMI)

Remote Terminal Unit

Sensors

Pressure

Pump/fan speed

Noise Level

Oil levels and Maintenance alarms

Radioactivity levels

Water levels

Temperature

Flow Rate

Vulnerability assessment, patch management and auditing of all organizational assets (FortiClient)

Page 10: Bezpečnosť kritickej infraštruktúry bez kompromisov! · Deep SCADA Understanding Unintrusive Passive Monitoring … our Answer is an Active Integration between SCADAguardian and

10

Fortinet Security Fabric for IT/OT Convergence Corporate LAN

Domain Controller

Business Systems

Supervisory Control System and associated databases

Human Machine Interface (HMI)

Remote Terminal Unit

Sensors

Pressure

Pump/fan speed

Noise Level

Oil levels and Maintenance alarms

Radioactivity levels

Water levels

Temperature

Flow Rate

Implement FSF (Fortinet Security Fabric) for end-to-end awareness and control across both IT and OT environments

Page 11: Bezpečnosť kritickej infraštruktúry bez kompromisov! · Deep SCADA Understanding Unintrusive Passive Monitoring … our Answer is an Active Integration between SCADAguardian and

11

Fortinet Security Fabric from IoT to Cloud

Network Secure LAN Access

Secure WLAN Access

Secure Cloud

Secure Devices

SandboxingPolicy

EmailSecurity

WebSecurity

Network & SecurityOperations

ThreatIntelligence

PartnerIntegration

Automated Operations§ Inner Core Network Security§ Outer Core Security

» Access, Cloud & Endpoints§ Extended Security

» ATP, Email, Web & Policy§ Threat Intelligence§ Security Operations§ Partner Integration

Infrastructure

Page 12: Bezpečnosť kritickej infraštruktúry bez kompromisov! · Deep SCADA Understanding Unintrusive Passive Monitoring … our Answer is an Active Integration between SCADAguardian and

12

Behavioral Analysis

Deep SCADA Understanding

UnintrusivePassive

Monitoring

… our Answer is an Active Integration between SCADAguardian and Fortigate

Automatically learns ICS behavior and detects suspicious activities

Security Policy Enforcement

Flexibility to enforce security policies with different degree of granularity

Deep understanding of all key SCADA protocols,

open and proprietary

Active Traffic Control

Proactive filtering of malicious and unauthorized network traffic

Real-time passive monitoring guarantees no performance impact and

permits visibility at different layers of the Control and Process Networks

In-lineProtection

In-line separation between IT and OT environments

Turn–key Internal and Perimeter Visibility

Fine Tuning, Control and Monitoring of the Firewall Ruleset

Proactive SCADA Security

Page 13: Bezpečnosť kritickej infraštruktúry bez kompromisov! · Deep SCADA Understanding Unintrusive Passive Monitoring … our Answer is an Active Integration between SCADAguardian and

13

Valve

Fan

Pump

Responding to Threats in Real Time

1

1 MonitorA threat is detected by SCADAguardianand an alert is generated

2 DetectUser-defined policies are examined and the appropriate corresponding action is triggered

2

3 ProtectFortiGate responds according to the user-configured action (Node Blocking, Link Blocking, or Kill Session) in order to mitigate the issue

3

Page 14: Bezpečnosť kritickej infraštruktúry bez kompromisov! · Deep SCADA Understanding Unintrusive Passive Monitoring … our Answer is an Active Integration between SCADAguardian and

14

Fortinet’s ICS Layered Defense Model

APT Framework•Advanced Malware•Automation•Interaction

Defense-in-Depth•Multiple Layers•Exploit Vectors•Data Protection

Internal Segmentation•Untrust Model•Breach Containment•Security Corridors

Fortinet ICS Layered Defense Model

DinD

APTIS

Page 15: Bezpečnosť kritickej infraštruktúry bez kompromisov! · Deep SCADA Understanding Unintrusive Passive Monitoring … our Answer is an Active Integration between SCADAguardian and