bsc6900v900r012 uo global and equipment data configuration-20101218-b-v1.0

50
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved www.huawei.com Internal Global and Equipment Data Configuration ------Based on MML Commands BSC6900V900R012

Upload: alfredo

Post on 21-Apr-2015

343 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved

www.huawei.com

Internal

Global and Equipment Data Configuration

------Based on MML Commands

BSC6900V900R012

Page 2: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 2

Upon completion this course, you will be able to:

Master the procedure and methods of data

configuration of BSC6900

Master global and equipment data configuration

Page 3: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 3

《 (For Customer)BSC6900 UMTS Product

Documentation(V900R012C00_01)-EN 》

《 BSC6900 UMTS Initial Configuration

Guide(V900R012C00_01) 》

Page 4: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 4

Chapter 1 Data Configuration Overview

Chapter 2 Global Data Configuration

Chapter 3 Equipment Data Configuration

Page 5: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 5

Web Local Maintenance Terminal ( MML Client )

The local maintenance terminal is an item of the LMT software.

The local maintenance terminal adopts the GUI and the MML

(Man Machine Language) to operate and maintain the system.

Note: Data configuration is realized by the MML commands.

Page 6: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 6

Application Scenarios of MML

Deployment

During the deployment, engineers should configure BSC6900 data

configuration script according to the negotiation data for stand alone

RNC during initial setup and run the script by MML commands in

batches.

Modify a few configuration data

When a few configuration data need to be modified, every single MML

command can be run to execute the function.

Data Preparation for Initial Configuration

In the BSC6900 initial configuration, some data is obtained from the

data sheets after negotiation with other network elements.

data preparation

Page 7: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 7

Open Web LMT Enter the external virtual IP address of the OMU in the address bar

on the IE

Page 8: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 8

Data Configuration Methods

1. Effective data configuration mode

2. Ineffective data configuration mode

Page 9: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 9

Data Configuration Overview

Configuration Command Action Description

Action Meaning

ADD Add an object

SET Set an object

LST Query BAM database configuration information

DSP Query FAM object state or BAM running state

MOD Modify an object

RMV Remove an object

ACT Activate an object

DEA Deactivate an object

RST Reset an object

What is different between LST and DSP ?

Page 10: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 10

Data Configuration Overview

Data Configuration Control

BSC6900 controls whether LMT or M2000 has the permission

to configure the data at a time to avoid the data conflict

Check the status of CMC (REQ CMCTRL)

Procedure of obtaining CMC in different cases

Lock CMC

If … Then …

M2000 communicates with BSC6900

normally

Use the REQ CMCTRL command to request the CMC.

If M2000 approves, LMT will get it

M2000 cannot communicate with BSC6900 or

BSC6900 is not equipped with M2000

Use the FOC CMCTRL command to obtain the CMC

forcibly

Page 11: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 11

Data Configuration Overview

Configuration procedures of initial setup RNC

Global dataconfiguration

Equipment data configuration

Interface dataconfiguration

Cell data configuration

Start

End

BSC6900

BSC6900

NodeB

NodeB

NodeB

MSC Server

MGW

SGSN

UE UTRAN CNUu Iu

Iu-CS

Iu-PS

Iur

Iub

Iub

Iub

Page 12: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 12

Chapter 1 Data Configuration Overview

Chapter 2 Global Data Configuration

Chapter 3 Equipment Data Configuration

Page 13: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 13

Global Data Configuration Procedure

End

Start

Adding RNC basic data

Configuring the OPC and DPC

Configuring the Area Information

Adding M3UA local and destination entities

Global parameter is used to identify the

RNC in a network.

This is the first step of RNC initial

configuration, use SET CFGDATAINEFFECTIVE

command switch RNC all

subrack to ineffective mode.

During the RNC initial configuration,

global data include several necessary

steps as shown in right procedure flow.

Page 14: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 14

Configure RNC Basic Data Information

ADD URNCBASIC :

ADD UCNOPERATOR :

ADD UCNOPERGROUP:

SET UOPERATORCFGPARA : optional

SET UOPERATORSHARINGMODE : optional

SET SUBNET : optional

SET SCTPSVRPORT: optional

End

Start

Adding RNC basic data

Configuring the OPC and DPC

Configuring the Area Information

Adding M3UA local and destination entities

Page 15: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 15

What is IU-FLEXIUFLEX features:

All CN node connecting to the RNC belongs to one operator

Why IUFLEX:

To enable load share in one CN domain, in a case when RNC

has more capacity then CN, by connecting to CN pool, RNC

resource could be more efficiently used

One CN node serves more RNC, this decrease CN switch and

roaming, and thus less CN signaling

CS3

RNC

NodeB

PS2

One Operator

CS2CS1PS1 PS3

Page 16: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 16

What is MRNC (ran sharing)

MRNC ( Multi-logical RNC ) is to configure one physical RNC to be

several logical RNC, the logical RNC belongs to different operators

Operator has its own CN, CN is not shared

Radio resource is not shared among operators

The feature RAN SHARING supported in V1.8 is MRNC

CS2

RNC

CS1

Operator_A

PS1

Operator_B

PS2

Cell1

Cell2

Cell3

Cell4

Page 17: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 17

What is MOCN

MOCN features:

Each operator has its own CN, CN is not shared

Radio resource is shared among operators, i.e. the cell is shared

among operators

Each operator may deploy Iu-flex

RNC is responsible to route the UE to its subscribing operator

CS2

RNC

NodeB

CS1

Operator_A

PS1

Operator_B

PS2

Page 18: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 18

RNC id range is 0-4096 and used to uniquely identifying an RNC in same

operator network.

ATM address: use to distinguish equipment in ATM transmission network.

Configure RNC Basic Data Information

Paramters of ADD URNCBASIC command

Page 19: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 19

Configure RNC Basic Data Information

Paramters of ADD UCNOPERATOR command

Cn Operator Name: Value range: String long 1 ~ 31

Mobile country code: MCC Value range: 000 to 999

Mobile network code: MNC Value range: 00 to 99 or 000 to 999

Cn Operator index: Value range: 5-31

Page 20: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 20

PRIM: Primary operator, determines functions to be supported the entire RAN system

and allocates licenses to secondary operators. The primary operator permits registration

and access the UE.

SEC: Secondary operator, functions to be supported the entire RAN system and the

license of the secondary operators are controlled by primary operator. Secondary

operator permit access UE.

OUTER: Outer operator, In mobility management, UEs need to be hand over from the

operator of the source RNC to the operator of the target RNC. If the operator is not the

primary operator and secondary operator of the source RNC, you need to specify the

operator as an outer operator so that the operator support the mobility management.

COMM: operator that supports non-support UEs, The PLMN ID indicated in the

system broadcast information as defined for conversational networks, which non-support

UEs understand as the serving opertaor.

Configure RNC Basic Data Information

Page 21: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 21

Configure RNC Basic Data Information

ADD CNOperator correlative concept

MCC: Mobile country code MNC: Mobile network code MSIN: To identify the MS in one PLMN IMSI: To identify the MS in one Country

MCC MNC MSIN

3 digits 2/3 digits

Not more than 15 digits

IMSI (International Mobile Subscriber Identity)

NMSI

Page 22: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 22

Configure RNC Basic Data Information

Paramters of ADD UCNOPERGROUP command

In one operator group, can be configure 1-4 real operator index

In one operator group, can choose to configure one common operator index.

CNOPERATORGROUP is to facilitate maintenance and management.

Page 23: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 23

Configure RNC Basic Data Information

Paramters of SET UOPERATORCFGPARA command

If the RNC system support IU-FLEX and MOCN , this command use to configure

NRI parameter.

NRI (network recourse identifier) is part of the temporary indentity TMSI (CS

domain) or P-TMSI (PS domain), which is assigned by the serving CN node to the

UE.

Page 24: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 24

Paramters of SET UOPERATORSHARINGMODE command

RAN Sharing Support: Multiple operators to share a set of

RAN equipment that covers the same area.

MOCN: Multi-operator share frequency resource mode.

Intra RAT Inter Plmn Ho Allowed: Intra Plmn handover.

Inter RAT Inter Plmn Ho Allowed: Inter Plmn handover.

Configure RNC Basic Data Information

RNC1

Operator 2

RNC2

RNC3

Operator 1

Page 25: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 25

Set RNC Internal Subnet No.

EPS

SCU

80.x.x.x

Configure RNC Basic Data Information

EPS

BAMExternal

BAMInternal

Page 26: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 26

Parameter of SET SCTPSRVPORT command.

Configure RNC Basic Data Information

The default parameter:

NBAP port No. is 58085.

M3UA port No. is 2910.

Page 27: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 27

Configuring the OPC and DPC

ADD OPC:

ADD N7DPC :

End

Start

Adding RNC basic data

Configuring the OPC and DPC

Configuring the Area Information

Adding M3UA local and destination entities

Page 28: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 28

Parameter of ADD OPC command

Configuring the OPC and DPC

OSP name: <NAME> 1~31 characters. OSP code bits: <SPCBITS> Value range: BIT14, BIT16, BIT24.

Network ID:

INT: international network.

INTB: international reserved.

NAT: national network.

NATB: national reserved.

Page 29: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 29

ADD N7DPC

Configuring the OPC and DPC

DSP type : IUCS(IUCS), IUPS(IUPS), IUR(IUR), IUCS_RANAP(IUCS_RANAP),

IUCS_ALCAP(IUCS_ALCAP), AAL2SWITCH(AAL2SWITCH), STP(STP), IUPC(IUPC)

SS7 type: ITUT(International Telecommunication Union - Telecommunication Standardiza

tion Sector), ANSI(American National Standards Institute), and TTC(Telecommunication Te

chnology Committee (Japan)).

Page 30: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 30

Configuring the Area Information

ADD ULAC:

ADD URAC:

ADD USAC:

ADD UURA:

ADD UCZ: optional

End

Start

Adding RNC basic data

Configuring the OPC and DPC

Configuring the Area Information

Adding M3UA local and destination entities

Page 31: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 31

ADD ULAC: Add location area code

ADD URAC: Add route area code

ADD USAC: Add service area code

ADD UURA: Add UTRAN Registration Area

PLMN: Public Land Mobile Network

Configuring the Area Information

LAC1

RAC1RAC2

SAC1SAC2

LAC2

PLMN

Page 32: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 32

UE States

CELL_DCH CELL_FACH

CELL_PCHURA_PCH

IDLE

DEAD - Scanning networks (PLMN)- ”Camp on” cell

- Monitor paging channel- cell re-selection

- Dedicated Channel- Radio bearers Transmission Services

- upper layer Signalingtrigger (CN)

- Reduce action , DRX , and save power

RRC connection

Configuring the Area Information

Page 33: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 33

Parameter of ADD ULAC command

Configuring the Area Information

LAI (location area identity)=MCC+MNC+LAC

When the system information is being broadcast in a cell, the value of the tag included in the system information block 1 (SIB1) message is within the range defined by PlmnValTagMin and PlmnValTagMax.

Page 34: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 34

Parameter of ADD URAC command

Configuring the Area Information

RAI (Route area identity) =MCC+MNC+LAC+RAC

Page 35: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 35

Parameter of ADD USAC command

Configuring the Area Information

SAI (Source area identity) =MCC+MNC+LAC+SAC

Page 36: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 36

Parameter of UTRAN Registration Area command

Configuring the Area Information

Use this command to add a UTRAN registration area

URA is used by UTRAN , CN does not know URA 。 URA is

formed by multiple cells. When UE goes to URA_PCH state, UE’s

area information is identified by URA.

Page 37: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 37

Configure M3UA Local and Destination Entities

End

Start

Adding RNC basic data

Configuring the OPC and DPC

Configuring the area information

Adding M3UA local and destination entities ADD M3LE: IP network mandatoryADD M3DE : IP network mandatory

This command only use for IU interface IP network.

The prerequisite is OPC and N7DPC configured.

Page 38: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 38

Chapter 1 Data Configuration Overview

Chapter 2 Global Data Configuration

Chapter 3 Equipment Data Configuration

Page 39: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 39

Equipment Data Configuration

Equipment data configuration is used to

identify the subracks, boards and clock

information of RNC.

This is the second configuration step of

RNC initial configuration.

During the RNC initial configuration,

equipment data include several necessary

steps as shown in the right procedure flow.

Adding the IP Address of the EMS Server

End

Start

Configuring a Cabinet

Configuring a Subrack

Configuring a Board

Adding an EMU

Configuring RNC Clock Data

Setting RNC Time

Configuring the System Information

Page 40: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 40

Equipment Data Configuration

SET SYS: optional

Adding the IP Address of the EMS Server

End

Start

Configuring a Cabinet

Configuring a Subrack

Configuring a Board

Adding an EMU

Configuring RNC Clock Data

Setting RNC Time

Configuring the System Information

The RNC system information is stored only in the BAM database and is not sent to the host,

Page 41: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 41

Configuring a Cabinet

ADD CAB: add an Extended Processing

Rack (EPR).

Adding the IP Address of the EMS Server

End

Start

Configuring a Cabinet

Configuring a Subrack

Configuring a Board

Adding an EMU

Configuring RNC Clock Data

Setting RNC Time

Configuring the System Information

The Main Processing Rack (MPR) is configured by default. It need not be added through the MML command.

Page 42: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 42

Configuring a Subrack

ADD SUBRACK: add more EPSs

SET SCUPORT : enable the

corresponding port on the SCU board in

the main subrack

Adding the IP Address of the EMS Server

End

Start

Configuring a Cabinet

Configuring a Subrack

Configuring a Board

Adding an EMU

Configuring RNC Clock Data

Setting RNC Time

Configuring the System Information

The Main Processing Subrack (MPS) is configured by default. It need not be added through the MML command.

Page 43: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 43

Configuring a Board

ADD BRD: This command can be used

by all types of boards except the SCUa,

GCUa, and GCGa.

SET MSP : Use this command to set

Multiplex Section Protection (MSP)

attributes for the

AOUa/AOUc/POUa/POUc/UOIc/UOIa (ATM

or IP) board.

Adding the IP Address of the EMS Server

End

Start

Configuring a Cabinet

Configuring a Subrack

Configuring a Board

Adding an EMU

Configuring RNC Clock Data

Setting RNC Time

Configuring the System Information

Page 44: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 44

Configuring an EMU

ADD EMU: The EMU gathers Boolean

values, analog values, and alarm threshold

information and reports them to the LMT.

One cabinet can be configured with only

one EMU.

Adding the IP Address of the EMS Server

End

Start

Configuring a Cabinet

Configuring a Subrack

Configuring a Board

Adding an EMU

Configuring RNC Clock Data

Setting RNC Time

Configuring the System Information

Page 45: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 45

Configuring RNC Clock Data

ADD CLKSRC: 增加系统时钟源

SET CLK:设置接口板时钟源

SET CLKMODE:设置系统时钟源工作模式

Adding the IP Address of the EMS Server

End

Start

Configuring a Cabinet

Configuring a Subrack

Configuring a Board

Adding an EMU

Configuring RNC Clock Data

Setting RNC Time

Configuring the System Information

Clock source priority ranges from 1 to 4. The clock source of priority 0 is configured by default. Priority 0 is the lowest priority, and priority 4 is the highest priority.

Page 46: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 46

Setting RNC Time

SET TZ:

ADD SNTPSRVINFO : information about the

SNTP synchronization server.

SET SNTPCLTPARA : set the synchronization

period of the SNTP client

Adding the IP Address of the EMS Server

End

Start

Configuring a Cabinet

Configuring a Subrack

Configuring a Board

Adding an EMU

Configuring RNC Clock Data

Setting RNC Time

Configuring the System Information

Page 47: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 47

SNTP serverSNTP server

SNTP client

SNTP clientSNTP server

RNC NodeBM2000

Setting RNC Time

RNC external network view: M2000 is the SNTP server of RNC

RNC is the SNTP client of M2000.

RNC internal network view: RNC is the SNTP server of NodeB

NodeB is the SNTP Client of RNC.

Page 48: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 48

Setting RNC Time

SNTP: Simple network time protocol.

SNTP server IP is the IP address of M2000. Port number is 123.

The number of the SNTP Servers cannot exceed 16.

If multiple SNTP servers are configured, SNTP Client chooses the best

SNTP server as the clock source according to the algorithm defined in

the NTP protocol.

Parameter of SET SNTPCLTPARA command

Page 49: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 49

Adding the IP Address of the EMS Server

ADD EMSIP:

Adding the IP Address of the EMS Server

End

Start

Configuring a Cabinet

Configuring a Subrack

Configuring a Board

Adding an EMU

Configuring RNC Clock Data

Setting RNC Time

Configuring the System Information

Page 50: BSC6900V900R012 UO Global and Equipment Data Configuration-20101218-B-V1.0

Thank youwww.huawei.com