calpeda ng

Upload: 2009tamer6138

Post on 07-Feb-2018

229 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/21/2019 Calpeda Ng

    1/5

    ConstructionClose-coupled self-priming shallow well jet pumps with

    built-in ejector.

    ApplicationsFor drawing water out of a well.

    As pressure boosting pump for central water systems with

    low pressure (follow local specifications if increasing network

    pressure).

    For clean liquids or slightly dirty surface water.

    For garden use.

    For washing with a jet of water.

    Operating conditionsLiquid temperature up to 40 C.

    Ambient temperature up to 40 C.

    Maximum permissible working pressure up to 10 bar.

    Continuous duty.

    Motor2-pole induction motor, 60 Hz (n = 3450 rpm).

    NG: three-phase 220/380 V.

    NGM: single-phase 220 V, with thermal protector up to 1.1 kW.

    Insulation class F.

    Protection IP 54.

    Constructed in accordance with: EN 60335-2-41.

    Special features on request- Other voltages.

    - Protection IP 55.- Special mechanical seal

    155

    Self-Priming Jet PumpsNGNG 60 Hz60 Hz

    MaterialsComponents NG B-NGPump casingCover with lantern bracket

    Cast iron Bronze

    Diffuser plate GJL 200 EN 1561 G-Cu Sn 10 EN 1982

    Impeller Brass P- Cu Zn 40 Pb 2 UNI 5705

    Shaft Chrome steel

    AISI 430 for NG 3-4 Cr-Ni-Mo steelChrome-nickel steel AISI 316

    AISI 303 for NG 5-6-7Diffuser - Ejector PPO-GF20 (Noryl)

    Mechanical seal Carbon - Ceramic - NBR

    Coverage chart n = 3450 rpm

    NG 7NG 6

    NG 5NG 3NG 4

    0

    72.837

    202 4 6 8 10

    0 40 80 120 160

    100

    0 10 20 30

    0 10 20 30 40

    60

    100

    200

    300

    U.S. g.p.m.

    Imp. g.p.m.

    mft

    020

    2 4 6 8 100 40 80 120 160

    100

    0 10 20 30

    0 10 20 30 40U.S. g.p.m.

    Imp. g.p.m.

    mft

    40

    60 3~

    1~

    3

    1

    150

    200

    015

    2 4 6 8 100 40 80 120 160

    100

    0 10 20 30

    0 10 20 30 40

    30

    65

    m /hl/min

    3

    U.S. g.p.m.

    Imp. g.p.m.

    m ft

    020

    1 2 3 4 150 20 40 60 80

    0 5 10 15

    0 5 10 15 20U.S. g.p.m.

    Imp. g.p.m.

    m

    ft40

    60

    100

    15050

    50

    150

    200

    l/minm /h3

    l/minm /h3m /h3

    l/min

    H

    Q

    H

    H

    Q

    H

    H

    Q

    H

    H

    Q

    H

    7/16

    7/18

    7/22

    6/18

    6/22

    5/16

    5/18

    5/22

    3

    4

    24

    01/2009

  • 7/21/2019 Calpeda Ng

    2/5156

    Self-Priming Jet PumpsNGNG 60 Hz60 HzPerformance for suction lift Hs = 1 m n = 3450 rpm

    Dimensions and weights

    Installation examples

    4.93.100

    Positive suction head operation

    Check valve.

    Suction lift operation

    Check valve.

    3.93.100.1

    1 m

    a1 a2 f h1 h2 h3 m1 m2 m3 n1 n2 b s w g

    G 1 G 1 127 8 430 150 43 203 60 52 8 185 155 35 9,5 100 1118,4

    19,2

    20,8

    21,5

    G 11/2 G 1 160 10 560 165 57 197 60 50 10 215 175 40 11,5 115 11

    29,2

    30,8

    31,3

    31,2

    32,8

    33,3

    DN2DN1TYPE

    kg

    NG B-NG

    NG 5E-60 B-NG 5E-60

    NG 6E-60 B-NG 6E-60

    NG 7E-60 B-NG 7E-60

    ISO 228

    NG 3E-60 B-NG 3E-60

    NG 4E-60 B-NG 4E-60

    DN2

    DN1

    a2 a1

    f

    h3

    m1

    m2 m3

    w

    h1

    h2

    4.93.104

    s

    n2

    b

    n1

    g

    P2 Rated motor power output.

    B-NG, B-NGM = Bronze construction.

    Qm3/h

    l/min

    0,25 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6 6,5 7 8 9 9,5

    4,1 8,3 16,6 25 33,3 41,6 50 58,3 66,6 75 83,3 9 1,6 100 108 116 133 150 158

    NG 3E-60B-NG 3E-60 3,6 2,1

    NGM 3E-60B-NGM 3E-60 5,2 3,1 0,55 0,75 49

    42NG 4E-60B-NG 4E-60 4,5 2,6NGM 4E-60

    B-NGM 4E-60 6,9 3,1 0,75 1

    B-NG 5/16E-60 5,7 3,3 B-NGM 5/16E-60 8,5 3 1,1 1,5

    B-NG 5/18E-60 5,7 3,3 B-NGM 5/18E-60 8,5 3 1,1 1,5

    B-NG 5/22E-60 5,7 3,3 B-NGM 5/22E-60 8,5 3 1,1 1,5

    B-NG 6/18E-60 9 5,2 1,5 2

    B-NGM 6/22E-60 10,6 3,8 1,5 2

    B-NG 7/16E-60 10,7 6,2 2,2 3

    B-NG 7/18E-60 10,7 6,2 2,2 3

    B-NG 7/22E-60 10,7 6,2 2,2 3

    P2

    kW HP

    1 ~ 220V

    A IA/IN

    3 ~ 220V 380V

    A A IA/IN

    B-NGM 6/18E-60 10,6 3,8 1,5 2

    B-NG 6/22E-60 9 5,2

    3,7

    4,5

    5,3

    5,3

    5,3

    6

    5,9

    5,9

    5,9

    6 1,5 2

    Hm

    45

    41

    40

    37,5

    58

    49

    37

    60

    54

    50

    44

    82

    71

    57

    35

    35

    54

    47

    36

    58

    51

    48

    42,5

    77

    68

    56

    32

    32

    50

    44

    35

    56

    49

    47

    41

    72

    65

    55

    27

    30

    46

    41,5

    34

    53

    46

    45

    40

    67

    63

    54

    27

    42,5

    39

    33

    50

    44

    44

    39

    62

    60

    52

    24

    40

    37,5

    31,5

    48

    41

    42,5

    37,5

    57,5

    57

    51

    22

    37,5

    35

    30

    45

    39

    41

    36

    54

    55

    49,5

    36

    33

    29

    43

    38

    40

    35

    52,5

    48

    31,5

    28

    41

    35

    39

    34

    51

    47

    30

    26,5

    39

    34

    37

    32,5

    49

    45

    29

    25,5

    36

    32

    36

    31,5

    47

    44

    24

    35

    30

    45

    42

    23

    33

    29

    41

    20,5

    31

    27

    38

    18

    28

    25

    35

    17

    27

    24

    33Tolerances according to ISO 9906, annex A.IA/IN = D.O.L. starting current / Rated current

  • 7/21/2019 Calpeda Ng

    3/5157

    Self-Priming Jet PumpsNGNG 60 Hz60 HzCharacteristic curves n = 3450 rpm

    24

  • 7/21/2019 Calpeda Ng

    4/5158

    Self-Priming Jet PumpsNGNG 60 Hz60 HzCharacteristic curves n = 3450 rpm

  • 7/21/2019 Calpeda Ng

    5/5159

    Self-Priming Jet PumpsNGNG 60 Hz60 HzCharacteristic curves n = 3450 rpm

    24