dect 原理与测试介绍

28
DECT 原原原原原原原 原原原原原 http://www.testdevgroup.com

Upload: sancha

Post on 19-Mar-2016

408 views

Category:

Documents


50 download

DESCRIPTION

DECT 原理与测试介绍. 测试开发网 http://www.testdevgroup.com. DECT 介绍. What is DECT? Wireless Cordless Telecommunication Standards DECT Technical Summary How does DECT work? DECT 相关名词缩写解释 DECT 测试项目 使用 CMD60 进行 DECT 测试. What is DECT?. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: DECT  原理与测试介绍

DECT 原理与测试介绍

测试开发网http://www.testdevgroup.com

Page 2: DECT  原理与测试介绍

http://www.testdevgroup.com

DECT 介绍

• What is DECT?• Wireless Cordless Telecommunication Standards• DECT Technical Summary• How does DECT work?• DECT 相关名词缩写解释• DECT 测试项目• 使用 CMD60 进行 DECT 测试

Page 3: DECT  原理与测试介绍

http://www.testdevgroup.com

What is DECT?

DECT –Digital Enhanced Cordless Telecommunications( 数字增强无绳电话 ) 最初 DECT为 Digital European Cordless Telecommunications ( 欧洲数字无绳电话 ) 的缩写 , 后来为了将 DECT 在更大范围内推广将 European 改为 Enhanced.

DECT 是在 CT2 和 CT3 的基础上开发的无绳通信标准DECT 标准最初发表于 1992 年 - ETS 300 175 and ETS 300 176 DECT 最新标准为 DECT6.0

DECT 工作于 1880MHz 到 1900MHz 频段使用 GFSK 调制方式 .DECT 支持的服务 :PSTN,ISDN,Wireless PABX,etc.

CT2 第二代无绳电话通信标准 CT3 第三代无绳电话通信标准PSTN 公共交换电话 网 ISDN 中文名称是综合业务数字网,通俗称为“一线通” PABX 数字程控交换机

Page 4: DECT  原理与测试介绍

http://www.testdevgroup.com

Wireless Cordless Telecommunication Standard

PACS-UA PACS variant A for the US unlicensed bands, related to PHS PACS-UB PACS variant B for the US unlicensed bands(WACS TDD)

Page 5: DECT  原理与测试介绍

http://www.testdevgroup.com

DECT Technical Summary

Page 6: DECT  原理与测试介绍

http://www.testdevgroup.com

DECT Technical Summary

Page 7: DECT  原理与测试介绍

http://www.testdevgroup.com

DECT Technical Summary

Page 8: DECT  原理与测试介绍

http://www.testdevgroup.com

DECT Technical Summary

Page 9: DECT  原理与测试介绍

http://www.testdevgroup.com

DECT Technical Summary

Page 10: DECT  原理与测试介绍

http://www.testdevgroup.com

DECT Technical Summary

Page 11: DECT  原理与测试介绍

http://www.testdevgroup.com

DECT Technical Summary

Page 12: DECT  原理与测试介绍

http://www.testdevgroup.com

How does DECT work?

Page 13: DECT  原理与测试介绍

http://www.testdevgroup.com

How does DECT work?

Page 14: DECT  原理与测试介绍

http://www.testdevgroup.com

How does DECT work?

Page 15: DECT  原理与测试介绍

http://www.testdevgroup.com

DECT 相关名词缩写解释

FP – Fixed Part 固定装置 . 即为 DECT Base Station 。PP – Protable Part 移动装置,手持设备。 DECT PhoneDECT Test Mode – 在 DECT 测试系统中 FP 必须在特殊的测试模式建立呼叫链接 , 在这种模式 FP 只接受测试消息 , 对于其他的信息一概忽略 .GAP Mode – 在 GAP Mode 使用默认的信号处理方式处理消息,对于测试消息则一概忽略。 在默认情

况 DECT 设备开机后即进入 GAP Mode.Dummy Bearer – 是 FP 送给 PP 的同步信号 .Dummy Bearer 是在 FP 锁定 PP 后 10ms 发送到 PP

的 , 它包含同步和认证信息 .Slot – Dummy Bearer 和 Traffic Bearer 的 Slot Number 的取值范围为 0 – 11, 并且不可以相同 . 此外相邻的 Slot (例如 5,6 或 11,0 )只有在 Dummy Bearer 和 Traffic Bearer 的 channel

number 相同时容许。对于有些 FP 只能采用偶数的 Slot ,而有些则只能使用奇数的 Slot 。如果需要 Traffic Slot 可以更改。

RFPI – Radio Fixed Part Identity 是一个数值用来标识 FP, 只有 PP 设置的 RFPI Number 和 FP 的RFPI 一致时才能建立会话连接。

PMID – Protable Part Mac Identity 是一个数值用来标识 PP ,大多数 FP 在测试模式时可以接受任何PMID ,并且 PMID 可以在会话建立起来后被 FP 检测出来。

PARK – Protable Access Rights Key 是一个密码用来设定 PP 只与特定的几个 FP 建立会话链接。IPUI – International Protable User Identity 是 PP 的一个数字标识,通过此标识 FP 可以和 PP 建立会话连接。当会话连接建立后 FP 会记录此标识。NTP - Normal Transmit Power 平均传输功率。

Page 16: DECT  原理与测试介绍

http://www.testdevgroup.com

DECT 测试

DECT 测试标准 :ETSI CTR/TBR-6 Radio Equipment and System(RES);Digital Enhanced Cordless

Telecommunications(DECT);General terminal attachment requirementsETSI CTR 6 / TBR 6 General Terminal Attachment Requirements: Radio Aspects (base standard ETS 300 176 Ed 2)ETSI CTR 10 / TBR 10 General Terminal Attachment Requirements: Telephony Applications (base standard

ETS 300 176 Ed 2)ETSI CTR 22 / TBR 22 General Terminal Attachment Requirements: Generic Access Profile (base standard

ETS 300 494 and ETS 300 497 Ed 2

DECT 测试仪器 :Anritsu - MT8801B Radio Communication Analyzer R&S – CMD60/CMD65 Digital Radiocommunication Tester R&S – TS1220 DECT Protocol TesterR&S – PTW15 DECT Signalling Test UnitAgilent – 8923A DECT Test Set [Obsolete] Agilent – 8923B DECT Test Set [Obsolete]

Page 17: DECT  原理与测试介绍

http://www.testdevgroup.com

DECT 测试项目

Accuracy and stability of RF carriers[TBR06-07]DECT 信道划分 :Fc = F0 - c x 1.728 MHz F0 = 1 897.344 MHz, c = 0,1, ..., 9.Test MethodThe carrier frequencies as measured shall be within ± 50 kHz of the appropriate nominal DECT carrierfrequency Fc.Frequency offset. It is obtained as the average of the demodulated signal over the B field for aselectable number of received bursts.

Accuracy and stability of timing parameters[TBR06-08]

Page 18: DECT  原理与测试介绍

http://www.testdevgroup.com

DECT 测试项目

Transmission burst[TBR06-9]Normal Transmitted Power (NTP)[TBR06-9.1.3]The NTP is the transmitted power averaged from the start of bit p0 of the physical packet to the end of the physical packet.

Power-time template[TBR06-9.4]The first bit of the burst (P0) derived from the modulation signal (not displayed) is used as the time reference. Bit P0 is derived with an accuracy of approx. 1/12 bit, ie approx. 0.075 ms.

Page 19: DECT  原理与测试介绍

http://www.testdevgroup.com

DECT 测试项目

RF carrier modulation [TBR06-11]Max ±B-Field Modulation[TBR06-11.3.2]The peak values of the modulation deviation measured over the B field that maximally and minimally deviate from the frequency offset.

Frequency drift [TBR06-11.7]

Page 20: DECT  原理与测试介绍

http://www.testdevgroup.com

DECT 测试项目

Radio receiver reference BER and FER [TBR06- 13.2]Set RF transmission to a power level of 70 dBmV/m (-73 dBm) at the input of the EUT receiver.The EUT should working on Loopback mode.

Page 21: DECT  原理与测试介绍

http://www.testdevgroup.com

使用 CMD60 进行 DECT 测试

CMD60 主要技术指标 :TX Frequency Accuracy ± 3 kHzTX Level Accuracy at RF IN/OUT <1.5 dBTX Level Accuracy RF OUT2 ± 5 dBAccuracy of Power Measurement at RF IN/OUT

< 2.5 dB in the range +30 to -10 dBm < 3 dB in the range -10 to -50 dBm

Page 22: DECT  原理与测试介绍

http://www.testdevgroup.com

使用 CMD60 进行 DECT 测试

Connect N socket RF IN/OUT of CMD60 with antenna connector of PP or FP. Alternatively, an antenna can be connected to the N socket for coupling via the air interface.

Select your EUT type: PP or FP

Page 23: DECT  原理与测试介绍

http://www.testdevgroup.com

使用 CMD60 进行 DECT 测试

设置参数 :

RFPI

PMID

TRAFFIC SLOT

TRAFFIC CARRIER

RF LEVEL

MODE

如果当前测试频段不是标准的欧洲频段 ,

需要设置 CARRIER # OFFSET 确保测试仪器和产品在相同的载波频率下 .

若要测试南美频段则需安装 K61 扩展选件 .

Page 24: DECT  原理与测试介绍

http://www.testdevgroup.com

使用 CMD60 进行 DECT 测试

所有设置项目设置完成后按“ SETUP CONNECT” 建立链接 .若仪器和产品设置正常则会进入如下测试界面 .

否则仪器会提示无法建立连接 .

若无法建立连接需考虑以下几个方面 :

1. 参数设置是否正确 ,RF 通路是否正常2. 产品是否工作于测试模式3. 产品是否工作于当前设置频段

Page 25: DECT  原理与测试介绍

http://www.testdevgroup.com

使用 CMD60 进行 DECT 测试

Power Template Test

Page 26: DECT  原理与测试介绍

http://www.testdevgroup.com

使用 CMD60 进行 DECT 测试

RF MODULATION Test

Page 27: DECT  原理与测试介绍

http://www.testdevgroup.com

使用 CMD60 进行 DECT 测试

Timing Jitter Test

Page 28: DECT  原理与测试介绍

http://www.testdevgroup.com

使用 CMD60 进行 DECT 测试

BER Test