WOOJIN Electric & Power Co., LTD.
Rev. 1.2.2
WOOJIN Electric & Power Co., LTD.Research & Development Institute/Science and Technology Agency
High Voltage
Porcelain
Station Post
Insulators
WOOJIN Electric & Power Co., LTD.
Contents
2/11
Design Features
Dimensions and Characteristics
Manufacturing Process
Products
Test Report
Drawing
Insulation Design
Rev. 1.2.2
Housing : 자기(Porcelain)
Material : 고강도 알루미나 소지 적용
Shed Profile : IEC 60071-1, IEC 60815
BIL 550에 따른 오손 설계
Regular shed type
Glaze Color : 갈색(Brown)
WOOJIN Electric & Power Co., LTD.
Design Features
HV Station Post
TR-287Standard : ANSI C29.9-1983(R1996)
End Fittings : 캡(Cap)
Material : 구상흑연주철(Ductile iron)
+ 용융아연도금(Hot dip galvanizing)
Tap : Ø127(5”) bolt circle
4-M16 or 5/8”-11UFS
Cement : Portland
3/11
Rev. 1.2.2
WOOJIN Electric & Power Co., LTD.
HV Station Post
Dimensions and Characteristics
4/11
Description TR-205 TR-208 C8-200Ⅱ
Applied standard ANSI C 29.9 ANSI C 29.9 IEC 60273
Rating, kV BIL 110 BIL 150 BIL 200
Height of Insulator, mm 254 355 475
Leakage Distance, mm 393 610 950
Bolt Circle,
mm(in)
Top (3) (3) 76
Base (3) (3) 76
Cantilever Strength, kN(lbs) (2,000) (2,000) 8
Tensile Strength, kN(lbs) (8,500) (10,000) -
Compression Strength, kN(lbs) (10,000) (10,000) -
Torsional Strength, kN-cm(in-lbs) (7,000) (8,000) 2
Low-Frequency Wet Withstand, kV 45 60 70
Impulse Withstand, kV 110 150 200
RIV
60㎐ Test Voltage, kV 10 15 -
Max. RIV @1,000㎑, ㎶ 50 100 -
Rev. 1.2.2
WOOJIN Electric & Power Co., LTD.
HV Station Post
Dimensions and Characteristics
Description TR-287 WEP R-bar
Applied standard ANSI C 29.9 ← IEC 60168
Rating, kV BIL 550 ← A.C 25
Height of Insulator, mm 1,143±1.6(45”±1/16”) ← 660±3
Leakage Distance, mm 2,515(99”) 1,020
Max. Cap Diameter,
mm(in)
Top Ø305(12”) Ø170mm(6.7”) Ø145
Base Ø305(12”) Ø170mm(6.7”) Ø161
Bolt Circle,
mm(in)
Top Ø127(5”) ← Ø120
Base Ø127(5”) ← Ø127
Cantilever Strength, kN(lbs) (2,600) ← 10
Tensile Strength, kN(lbs) (25,000) ← 80
Compression Strength, kN(lbs) (75,000) ← -
Torsional Strength, kN-m(in-lbs) (90,000) ← 4.5
Low-Frequency Wet Withstand, kV 230 ← 125
Impulse Withstand, kV 550 ← 275
Critical Impulse Flashover(Positive), kV 610 ← -
RIV60㎐ Test Voltage, kV 73 ← -
Max. RIV @1,000㎑, ㎶ 200 ← -
5/11
Rev. 1.2.2
WOOJIN Electric & Power Co., LTD.
TR-287 of HV Station Post
Manufacturing Process
M.P. of TR287
원료 계량 원료혼합 및 미분쇄 탈철 및 소지여과 필터 프레스
토련 및 압출 블랭크 건조
정형 자연건조
6/11
Rev. 1.2.2
WOOJIN Electric & Power Co., LTD.
TR-287 of HV Station Post
M.P. of TR287
건조
시유 소성
겉모양검사
냉열시험 시멘트 조립 및 양생 완제품
Manufacturing Process
7/11
Rev. 1.2.2
WOOJIN Electric & Power Co., LTD.
HV Station Post
TR-208
BIL 150kV
C8-200Ⅱ
BIL 200kV
TR-287
BIL 550kV
TR-205
BIL 110kV
Products
8/11
▶ [한국전기연구원(KERI)]대전력 발전설비 지지용 사용
▶ [한국핵융합연구소] 초고압(대용량)설비 지지용 사용
▶ [한국전기연구원(KERI)]대전력 발전설비 지지용 사용
▶ 발,변전소 등설비 지지용 사용
▶ 발,변전소 등설비 지지용 사용
Rigid-bar
A.C 25kV
▶ 한국철도 시설공단
▶ 신분당선 등
- ANSI Standard- IEC Standard
Rev. 1.2.2
WOOJIN Electric & Power Co., LTD.
HV Station Post(TR Series)
Test Reports
9/11
TR-208 TR-287
Rev. 1.2.2
WOOJIN Electric & Power Co., LTD.
HV Station Post(TR Series)
Drawing
10/11
TR-208 TR-287
Rev. 1.2.2
WOOJIN Electric & Power Co., LTD.
IEC60815(1986) ▶
IEC60071-1(1993-12)
▼
Insulation Design
Pollution levelMinimum nominal specific creepage distance1)
(mm/kV2))
Ⅰ- Light 16
Ⅱ- Medium 20
Ⅲ- Heavy 25
Ⅳ- Very heavy 31
1) For the actual creepage distance, the specified manufacturing tolerances are applicable (see IEC Publication 273: Dimensions of Indoor and Outdoor Post Insulators and Post Insulator Units for Systems with Nominal Voltages Greater than 1,000V, IEC Publication 305: Characteristics of String Insulator Units of the Cap and Pin Type, IEC Publication 433: Characteristics of String Insulator Units of the Long Rod Type, and IEC Publication 720: Characteristics of Line Post Insulators).
2) Ratio of the Leakage distance measured between phase and earth over the r.m.s. phase to phase value of the highest voltage for the equipment (see IEC Publication 71-1).
TABLE Ⅱ
Specific creepage distance(see column 2, Table Ⅱ)
(mm/kV)
Artificial pollution tests Severity withstand values at the phase-to-earth voltage
Salt fog method
(kg/㎥)
Solid-layer methods
S.D.D★)
(mg/㎠)
LayerConductivity
(μS)
16 5 to 14 0.03 to 0.06 15 to 20
20 14 to 40 0.10 to 0.20 24 to 35
25 40 to 112 0.30 to 0.60 36
31 >160 - -
TABLE Ⅲ
Highest voltage for equipment
Um
kV
(r.m.s. value)
Standard short-duration power-frequencywithstand voltage
kV
(r.m.s. value)
Standard lightning impulse withstand voltage
kV
(peak value)
52 95 250
72.5 140 325
123(185) 450
230 550
145
(185) (450)
230 550
275 650
170
(230) (550)
275 650
325 750
Note - If values in brackets are considered insufficient to prove that the required phase-to-phase withstand voltages are met, additional phase-to-phase withstand tests are needed.
TABLE 2 – Standard insulation level for range Ⅰ
(1 kV < Um < 245kV)
S.D.D★) = Salt Deposit Density.
HV Station Post
11/11
Rev. 1.2.2