f· · for variable head units, it may be possible to match the turbine rating with a ... ts for...

43
... I I , : , . UNIVERSITY OF MINNESOTA ST. ANTHONY FALLS HYDRAULIC LABORATORY Project Report No. 225 HYDROMECHANICS OF VARIABLE SPEED TURBINES .' by Cesar Farell, Javier Arroyave, Nicholas Cruz, and.John S. Gulliver .. Prepared for STATE OF MINNESOTA DEPARTMENT OFNAtVRAL RESOURCES St. Paul, Minnes.ota . August, 1983 Minneapolis, Minnesota , I'·t

Upload: phungmien

Post on 25-Apr-2018

218 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

... I

I

, :

, .

UNIVERSITY OF MINNESOTA

ST. ANTHONY FALLS HYDRAULIC LABORATORY

Project Report No. 225

HYDROMECHANICS OF VARIABLE SPEED TURBINES

.' by

Cesar Farell, Javier Arroyave,

Nicholas Cruz, and.John S. Gulliver

..

Prepared for

STATE OF MINNESOTA DEPARTMENT OFNAtVRAL RESOURCES

St. Paul, Minnes.ota

. August, 1983

Minneapolis, Minnesota

, I'·t

Page 2: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

e-

.j..

University of Minnesota st. Anthony Falls Hydraulic Laboratory

Project Report No. 225

HYDROMECHANICS OF VARIABLE SPEED TURBINES

by

Cesar F'arell, Javier Arroyave,

Nicholas Cruz, and John S. Gulliver

Prepared for

STATE OF MINNESOTA DEPARTMENT OF NATURAL RESOURCES

st. Paul, Minnesota

August, 1983

Page 3: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

ACKNOWLEDGEMENTS

This study was performed under the general supervision of Pro Roger E~A.

Arndt, Direotor of the St. Anthony Falls Hydraulio Laboratory, University

of Minnesota.

The University of Minnesota is committed to the policy that all persons shall have equal access to its programs, facilities, and employment without regard to race, creed, color, sex, national origin, or handicap.

i

Page 4: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

TABLE OF CONTENTS

Page No.

Acknowledgemen ts ....... ., ....... !II" '" ...... " " " .... '" •• " ... fI ............. '" i List of Figures •••••••••••••••••••••••••••••••••••••••••• iii

I . INTROOUCT ION " ..... II ....... _ .... " • ,. ..... " .. ,. " • ,. ~ .... , • " ,. ...... " .... tI • • .. .. 1

II. POSSIBLE APPLICATIONS OF THE VARIABLE-SPEED TURBINE 3

III. SIMILARITY CONDITIONS AND OPERATING CHARACTERISTICS 6

111.1. Specific Speed ••••••.••••••.•••.•••••••••••••••• 7

111.2. Performance Curves and Characteristic Diagr.ams " •. ""." ..... ,. "'''II' .... " .. " .... " .... "II'" " ... " ..... " .... 10

IV. VARIAB:J:,.E-SPEED TURBINE PERFORMANCE AT CONSTANT HEAD .,....... 12

V. SOME THEORETICAL CALCULATIONS •••••••••••••••••••••••••••••• 26

V.I. Axial-Flow Turbines .... '" ...... ~.. .. . . .. .. .. .. ... . .... .. .. .. ........... .. .. 28

V.2. Estimation of the Lattice Parameter <5 .'........... 30

V.3. Application to A&ial-F1ow Turbine A2 .............. 31

VI. SUMMARY AND CONCLUSIONS .. ,. ,. ........................... " ... " ... " ..... " ... " .. " .. " 35

VI I • REFERENCES ... " '" • ,. ....... it .. " ............ " " .... " ..... " .............. ' •• " .. ,. .. .. .. .. • .. .. 37

ii

Page 5: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

Fig. No.

1

2

3

4

5

6 (,

7

8

9.

10

11

12

13

14

LIST OF FIGURES

Turbine efficiency as a function of percent of full load. Constant speed operation.

Maximum efficiencies and turbine ranges as functions of specific speed.

Typical head-discharge-efficiency curves for an axial flow turbine.

Sketch of fixed-gate characteristic curves on H-Q plane for different speeds. (fi, Of n: best-efficiency values)

Variable speed characteristics for axial-flow turbine Al (N = 1.61, fixed gate and blades). s

Variable speed characteristics for axial-;Elow turbine A2 (N = 2.65, fixed gate and blades). s

Var iable speed chax:acteristics for axial-flow pump used as turbine (N = 2.68, fixed gate and blades). . s

Off-design. variable-speed performanqe' of fixed-gate, fixed-blade propeller turbines AI' AZ' and Pl' Constant­speed Kaplan curve also shown for comparison.

Variable-gate characteristic curves on H/a - Q/e plane '" " (H, Q: best efficiency values) •

Variable speed chax:acteristics of Francis turbine F3 (N = 1.43, fixed gate). s

Variable-speed characteristics of USBR pump turbine Tl (N =0.76). s .

Variable and fixed-speed characteristics'of USBR pump turbine Tl (Ns = 0.76).

Variation of turbine discharge versus rotational speed from measured performance characteristics and two analytical calculations (Eg. 14 and similarity calculations) •

Effect of parameter, 0, on the variation of turbine dis­charge with rotational speed. Determined from theoretical calculations.

iii

Page 6: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

r"

'.

I

I. INTROPUCTION

The increased use of wind-driven generators in the last few years has

resulted in special generator designs which ope):ate at varying speed and

frequency, utilidngstatic inverters for conversion of direct to alterna­

ting current. The potential application of this emerging technology to

hydropower production schemes has recently received considerable attention,

as witnessed, for e:ll:ample,by the recent DOE-El?RI (1983) workshop on applica­

tions of variable-speed generators in hydropowe):. Typically, a variable­

speed hyd.roelectric scheme would consist essentially of the turbine, a

synchronous generator (variable speed and frequency), a rectifier for the

generato!:" output, an inverter at the powerhouse and alternating current

transmission, or direct current transmission, and an inverter at the sub­

station.. Regardless of the speed variation.s, the inverters have the

ability to maintain virtually constant frequency and voltage for any given

load.

While ):ectifiers and inverters are added elements in variable--speed

schemes, certain simplifications and cost reductions 'may result in other

areas, which must be taken into account in potential cost benefit studies.

Although the purpose of the present report is to discuss hydromechanical

aspects of variable-speed turbine operation, a few generator and control

features are briefly touched upon here to give a more general perspective

of the overall pr.oblem. Fi.rst, since the generator output is recti;fied·

in' a var iable-speed scheme; the number of genel;ator poles can be optimized

to simplify generator construction, without regard for the electrical load.

Second, because of less severe requirements on voltage wave-forms, simpli­

fications may also be possible in both pole and stator windings. Third,

for variable head units, it may be possible to match the turbine rating

with a smaller generator by running at variable speed', because

a smaller output range results from variable speed operation, and

1

Page 7: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

r,:

c

more flexibility is then available to place the aesign heaa within the head

range. Fourth, waterhcunmer and goveJ:'ning problems are considerably simpli­

fied, resulting in savings in space, equipment, and maintenance. For low­

heaa, low-power applications in particular, constant-speed turbine-generator

units ,generally have low inertia constants which require the use of flywheels,

with or without speed reducers. For variable speed opeJ:'ation, the complica­

tion of control schemes which make up a large proportion of the total cost

for smaller units is considerably ,reduced OJ:' eliminated altogether. Contin­

\,1ously acting speed control and flywheels are not necessaJ:'y, although some

limited speed control may be necessary to provide operational limits and

load sharing between units.

For additional giscu13sion'of generator and inverter technology, the

reader is referred to Nair (1982) and the DOE-EPRI (1983) workshop. It

appears from the workshop presentations and results that the electric field

fs being actively investigated and there is a need for parallel research on

, the hydromechanical aspects of the turbines. Several types of variable

speed generators are presently being examined (including in pa):ticular

doubly fed machines) • Inverter technology is advancing rapidly, and research

and developmenteffo):ts for best conversion methods for wind-turbine, small­

hydro, and existing large-hydro power generation are under review.

The present report focuses on hydromechanical aspects of variable­

speed turbine operation. possible applications and advantages from a

bydromechanics point of view are briefly discussed in the next section,

similarity conditions are analyzed in section III, applications of simil­

arity laws to variable-speed turbine performance estimates are presented

in section IV 1 and some theoretical calculations fOr axial :flow (propeller)

turbines are discussed in section V. Finally, conclusions and ideas for

future research are briefly reviewed in section VI.

2

Page 8: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

II. POSSIBLE APPLICA'J;'IONS OF THE VARIABLE-SPEED TURBINE

Possible variable-speed turbine applications and benefits depeno on

the mode of plant operation, ano potential cost-benefit analyses require

the oefinition of operation scenarios. Sheldon (1~83) and Ale:Kanoer (1983)

have recently performed analysel:l of energy and wate,r gains for Francis

turbines under various conoitions of operation, using model tel:lt performance

data for specifio turbines already inl:ltalled. In principle, allowing for

variation of the turbine speed should result in the following advantages:

a) Improved performance at off-design heads and improved range of

oPerating heads. Low-head propeller turbines in particular can

experience q. very wide range of operating head as a percent of

design head.

b) Imp:rov,ed pe:rformance at off-design discharges and improved

range of operating discharges.

0) ImprQved performance for Pl,lmp-turbine units. Here if the

rotational speed is to be the same fo:r both turbine and pump

ope:rations, 'SOllle sacrifice in efficiency in eithe:r or both

modes is generally necessary. Pump-turbine applications

invOlve usually high heaos and relatively large head vari'a­

tions, ano require radial or mixed floW machines.

Wislicenus (1979) has pointed out that a:Kial-flow machines,

except for their low operatiri:g head, are'theoretical1y more

attractive as pump-turbines than radial-flow machines because

they.operate near optimum efficiency at a given rotational

speed in both the pumping and tllrbining modes. The use of

mu;I.ti-l:Itageaxial flOw units has been suggesteo.by Wislicenus

as a possible improvement. Obv iol,l sly , variable-speed opera­

tion of Francis unitl:l I:Ihould. also be examin,ed in this regard

because peak efficiency can be achieved without the expensive

mUlti-stage option.

3

Page 9: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

Determination of the potential benefits of the variable speed turbine

depends obviously on quantifying the improvements in perfotmance. The ):,e­

suIts of Sheldon (1983) for three specific Francis units (n ,== 24.5', 44,7, , s and 56.1 in English units) show that variable speed provides small in-

c):'eases in energy production relative to the wa.te):' used. For, three scenarios

with heada varying ,±50 percent from the best-efficiency head, Sheldon con­

sidered machines ope):'ating at best possible efficiency, at constant 0):'

m~imum possible powe):', and at constant or maximum possible discharge.

For the best possible efficiency case, an ene):'gy increase of 3.5 percent

and water saving of 0.1 percent resulted for ns = 24.5, while fo):'

n, 1= 56.1, the energy inc):'e:ase was smaller, 1. 6 percent, but the water s

saving of 4.9 perce~t was larger.

These results apply to the specific tu):'bines analyzed. othetunits

may behave diffe:r;ently, and it might be possible that tU,rbine design

optimization for va;riable speed may result in larger gains. As Alexander

(1983) has, pointed out, the turbines he used in his study (one of which

coincides with one of the units in Sheldon's (1983) analysis) were built

to provide a wide operating range rather than maximum peak efficiency.

Variable speed turbines designed fot highest efficiency should show greater , '

,improvements in energy recove):'y. For fixed-blade prope1ier turbines,

, which have very narrow operational ranges as a' percent of full load (see

Fig. 1), the results could be very different, in particular if large rela­

tive head'variations occur. Since fixed-blade propeller turbines are much

less costly than Kaplan turbines, their potential cost benefits should be

examined in detaiL

Developmet:t of software for producing benefit analyses relative to

a set of specific scena):'ios require that detailed turbine data,be avail­

able. These data are generally lacking, on the one hand because of the

propr ietary nature of the manufacturer's design information ~ and on the

other because many' developments in the design of small sca:J..e units are

relatively recent. Sometimes the available performance data does not

cover the entire ran~e of possible variable-speed operat~on. .Thus,

additional data, appears to be needed, as would be obtained in a turbine

test stand using scale models. In the following, the nature of the re­

quired data is illustrated in the light of several specific analyses.

4

Page 10: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

U1

tOO

90

~ 80 0

~;.: /..; ...... .;' .

... ~

0

c: 70 Q) . . -0 .-'+-

60 '+-W A - Ad jus tab 1 e B lad e 5 - A dj u 5 ta b 1 eGa t e s

8 - Adjustable Blades - Fixed Gotes

50 C -Fixed Blodes - Fixed Gates o -Fixed Blades -Adjustable Gates

40 E -I m p u Is e T u r bin e

20 30· 40 50 6070 80 90 1001 (0 120

Percent of Full Load

Fig. 1. Turbine efficiency as a function of percent of full load. Constant speed

operation.

Page 11: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

Ul. SIMIJ:,ARl'l'Y CONDITIONSANDOPERA'l'ING CHARACTERIS'l'ICS

The 9):'ouping of )?arameters b):'ought about by dimensional analysis

pe):'mits the writing of a )?hysical ):'elationship in terms of fewe):' dimen­

sionless quantities (n numbe):'s) rep):'esenting ratios of significant fo):'ces

fo):' the problem. This provides a method to ext):'a)?olate model test data

to .p):'oto.ty)?e situations by equating conesponding dimensionless numbers.

As ap)?lied to hydraulic machinery, similarity considerations provide,

futhermore, an answer to the following im)?ortant question: Given test

data on the performance characteristics of a certain type of machine under

. certain o)?er·ating conditions, what can be said about the performance

characteristics of the same machine, or of a geometrically similar machine

under different operating conditions? Similarity considerations provide,

in addition, a means of. cataloguing machine types and thus.aid in the

selection of the type suitable for a particular se.t of oonditions.

The problem of similarity of flow oonditons can be summarized.as

follows: Under what oonditions will geometrically similar flow patterns

with proportional velooitie.sand accelerations ocour .around or within

geometrioally similar bodies? obviously, the forces acting on corresponding

fluid masses must be pro)?ortionally related, as are the kinematic qu.anti­

ties, sO as to insure that the fluid will follow geometrically similar

paths. An answer to this question can be obtained by examining the funda­

mental laws of motion and identifying the.relevant forces. While these

laws cannot yet be used predict theoretically the flow conditions in a

machine with unknown performance characteristics, the information they

)?rovide on forces and boundary conditions enables the determination of an

answer to the similitude problem~ . .

For geometrioally similar maohines, kinematic similarity requires that

the ratio Q/r4D3 be the same' for model and prototype. Here Q is the

turbine discharge, n is the rotational speed in radians per seoond

(n = 2nn/60, where n = rotational speed in revolutions per minute) ,

6

Page 12: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

and D is a typical runner diameter. In the rotating coordinate system

this ratio represents also the ratio between inertial and centrifugal

forces, or equivalently the ratio between kinetic energy and the potential

energy of the ,centrifugal force.

The condition O/Q03 = constant is actually sufficient fo):, similarity.

The dynamic similadty oondition 9H/n 2D2;::: constant follows from the basic

laws and permits calculation of the head H for similar operating con­

ditions. For brevity, energy losses and volumetric efficiencies have been

left out of the discussion as presented here. Equality of hydraulic, vol­

umetric, and mechanical efficiencies is necessary for strict similarity.

Departures :J;rom this equality produce scale effects, a discussion of which

can be found in Arndt, Farell, and Wetzel (in press).

111.1. Specific Speed

Similar flow oonditions are ensured by the constancy of the ratio

Q/nD3 " which implies constancy of the ratio 9R/Q2D2. In other words

( 1)

This, relationship can also be written in terms of a third dimensionless

number which does not involv~ the representative dimensiO,n D of the

machine, and which can replace either of the two arguments in Eq. (JJ. Such a number can be obtained by appropriate multiplication of powers of

the dimensionless numbers in Eq. (1):

, , 3/4

N ';:::(~,' )1/2 (n2,D2) ;::: SQ QD3 ' gH

QQ1/2

(gH) 3/4 ( 2)

This dimensionless number is called the specific speed. For hydraulic

turbines, however, the definition of the specific speed is based on the

power Pdelivered by the turbine as a variable, instead of on the flow

rate Q. 'The corresponding, dimensionless number to ensure ,kinemat'ic

similarity for P is p/pQ3D5, which isa function of 9H/Q2D2 Elim-

inating ,D between these two numbers one gets,

N s

;::: n(p/p) 1/2

(gH) 5/4

7

(3)

Page 13: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

;':'>

The two specific speeds a!;e related by

which is obtained making use of the equation P = nyQH. If we choose

Ns as the independent variable in these relationships, then all other

dimensionless combinations can be e~pressed as functions of Ns

(4)

The specific speed describes a specific combination of operating con­

ditions that ensures similar flows in geometdcally similar machines. It.

has thus attached to it a specific value of efficiency, n (assumed

appro~imately constant for similar flow conditions regardless of size).

It is customary to label each ser ies of geometrically similar turbines by

the value of Ns which gives maximum n for the series. Unless other-

N value referred to when the terminology s wise stated, this is the

specific speed is used. The value of N thus defined permits the c1ass­s i;fication of turbines according to efficiency. Each geometric design has

a range of N values.where it can be used with only one value corres-s ponding to peak efficiency. Figure 2 shows the peak efficiency of various

types of turbines as a·function of specific speed.

The N , as it was defined here, is dimensionless. s It is common

practice to drop g and p from the definition and define

n S

n as S

(5)

with n in rpm. In English units, the units of P are horsepower, and

the units of H are feet. In metric units, the unit of P .is either the

metric horsepower or the kilowatt, and the unit of H is' the meter. The

relationships of these three definitions. of ns to the dimensionless Ns

are:

ns = 43.5 N (English units) s

n :; 193.1 N (Metric units· using metric horsepower) (6) s s

n :; 166 Ns (Metric s units . using KW for power)

8

Page 14: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

,7·

o 100 200 300 400 500 600 I I )

ns(METR I C; KW, M, RPM)

o I 20 40 60 80 . fOO 120 140 160 180 200 220 1___ __. __ L -·_I __________ J_. ______ .~ ~ ____ J

96 n s ( ENG LIS H ; HP, F T, RPM)

94

~ 92 ...

~ ~ 90 u c 88 Q) -~ 86

"l-

~. r---...... --r .............

~ '~

I "-L '" I

'" n ~ "' i:; 84

82

80

1

~. j. Fronds lurbines I Propeller turbines ..1 I I

- Singl,e no~zle limpulse

o 2 3 4 5 ,Ns

Fig. 2. Maximum efficiencies and turbine ranges as functions of specific speed.

Page 15: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

· Abcissa axes showing met:r.; ie and Englishuni ts have been added to

Fig. 2 fo:r.; convenience.

III.2. Performance Curves and Characte:cistic Diagrams

Typicalhead-diseharge-efficienoy performance curves for constant

speed operation for a £i~ed-blade, fi~ed-gate a~ial turbine are given in

Fig. 3. These curves show operating conditions of the turbine at point!3

other than the design or best efficiency point. From such a diagram it

is possible to obtain ope;rating conditions for the turbine at speeds

other than the design speed by using the two similarity conditions, which

give

Ql Q2 and

HI H2 = =

5"21 5"2 2 5"2 2 5"2 2 1 2

(7 )

In i'lddition, the efficiencies are assumed to be equal as well, nl = n2 •

In general, for a variable-gate turbine, a characteristic diagram can

be prepared with the dimensionless parameters in Eq. (1) as coordinates

.and the gate opening as parameter. Curves of constant efficiency can· be

shown on the diagram ,which is then known as a performance hill diagram.

Alternately, one can use the best efficiency vales of the parameters on

the coordinate axes to convert the diagram to· a percent discharge-percent

head diagram. Powe;t:" can also be used in one of the coordinate a~es .or as

an additional parameter (in dimensionless form). For a Kaplan turbine,

the blade angle is an· additional parameter.·

10

Page 16: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

-"'" ~,

; 180

EFFICIENCY 70

-en LL / ~60l= () - z w

w

(!) 80 50 (.)

a:: a::

<! w

..... :c a..

..... -u 72. 40 en >-

DISCHARGE 0

0 z

w 64 . 30 w

z· <.)

CD lL

a:: 56 20 LL

::> w

.....

48 1-1 ./ -110

40 r . I 10

.4 . . :. 8 (2 . I 6

HEAD BETWEEN INLET AND TAILWATER (FT)

Fig. 3. Typical head-discharge-efficiency curves for an axial flow turbine.

Page 17: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

(,

IV. VARIABLE-SPEED TURBINE PERFORMANCE AT CONSTANT HEAD

Va~iable-speed performance diagrams at constant head for two small

axial-flow turbines with fixed vanes ana blades, Al and A2 , an axial

pump used as a turbine, Pl , three Francis turbines, Fl , F2,and F3 ,

a pum~ turbine, Tl , and a Kaplan turbine, Kl , were obtained from in­

formation suppliea by manufacture:rs or available in the lite:rature. The

o:riginal information was in different form for the various cases investi­

gated, and the processing of the dat .. differed for each turbine, as outlined

below. The following table gives the specific speeds of the turbines

analyzed:

N s

n (kW ,m, rpm) n (hp,ft,rpm) s . s .

Al 1.61 267 70

A2 2.65 440 115

PI 2.68 444 116

Fl. 0.51 84 22

F2 0.81 134 35

F3 1.43 237 62

Tl 0.76 127 33

Kl 3.26 542 142 .

On the H-Q plane, if 'the fixed-gate character istic curve of a turbine

is known for a given speea, , the similarity laws c,an be used as explained in

the preceding section to obtain the characteristic curves at 'other speeds.

, Generally, the form of this H-Q curve is as shown in 11'ig. 4. If the tur­

bine fixed-gate I H-Q· curve at constant speed is steeper than the similar­

ity parabola linking equal-efficiency points, then it is seen that for

12

Page 18: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

'c:'

H/A H

4.5 ...--------,,~---,----_r_---__r____,_-____,

4.0

3.5

3.0

2.5

2.0

. 1.5

1.0

0 .. 5

FIXED BLADES n/~=1.5~1Io..J

SIMILARITY PARABOLA ('1]/1\ = CONSTANT)

'1]

n/~=I.O -~

./

/ /

/ /

I

/

/

I

/

/\51 MIL ARIIY PARABOLA

O~~~--L-------~------~------~------~ o 0.5 1.0 1.5 2.0 2.5

Fig. 4.

a/A a Sketch of fixed-gate characteristic curves on H-Q plane for

A - "'''' i different speeds. (H, Q, n: best-effic1ency values)

13

Page 19: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

constant H, Q will be an increasing function of n. The opposite is

true if the similarity parabola is steeper than the H-Q curve. .Both cases

actually can occur, as shown later on.

A computer program was prepared to carry out numerically the similar­

ity calculations indicated in the preceding paragraph. Original values

from the known performance curves of the turbine at oonstantspeed were

stored in disorete ;form, for small head increments (::.H, in reference

column matrices QREF(I), HREF(I), PREF(I), and EFF(I). The values genera­

ted using the similarity relationships for different turbine speeds were

stored .in matrices QFLOW 0: ,J), HEAD (I ,J), POWER (t ,J), EFF (I), and RPM (J) •

Here the inde~ I denotes a point in the original performance curve, and

the inde~ J identifies the speed. FOr constant head operation with

variable speeds, the elements of the matrix HEAD(I;J) were searched to

identify the intervals {::.H. where the constant-head value fell, and linear

interpolation was then used to calculate the other operational parameters.

These oalculations were performed for the axial turbines Al and

A2 , the axial pump PI' and the Francis turbine F 3' at fixed gate.

Similar oalculations for operational conditions other than constant head

H could also be performed by introducing the appropriate constraint in the

matrices. Only constant head results are presented in this report, however ~

Figure 5 shows the variable-speed characteristics of the axial-flow'

turbine Al (N s=1.61), with fixed gate and blade~at constant head. It is

seen that the discharge Q increases only slightly with the rotational

speed, n. This means that operating the turbine at variable speed will

not greatly facilitate flow control. Figures 6 and 7 present the corres­

ponding characteristics for turbine A2 and the' axial~f16w pump PI used

as turbine. (For turbine A2 , a peak efficiency value.fj = 0.9 was

assume.d in the calculations.) In both cases, there is a steeper rise of

the curve of discharge versus rotatiorial speed I which wili be discu.ssed

fUrther in section V. Figure S gives a comparison of variable-speed off­

design performance curves for turbines' AI' A2,and Pl' The corresponding

ourve for a full Ka)?lan,constant-speed turbine is also included. The

coordinates are percent of peak efficiency and percent of peak-efficiency

discharge to facilitate the comparison. The larger variation in discharge

14

Page 20: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

.... 80 tJ1

}-

:::> a.. ~ 60 0

}-}-c:{

;: 40 0 ..J -~

20

}-z w u a:: w a..

>-u z w u LL LL W

c "

100

CONSTANT HEAD OPERATION u

l" __ --------" ---- Q JBO ~ 75 f()

1-

80

60

40

20

o 150 175 200 225 250 275 TURBINE SPEED, RPM

7J

p

300

70 LL

w (.!)

65 a:: c:{

325

J: U (f)

o

Fig. 5. Variable speed characteristics for axial-flow turbine Al eNs = 1.61, fixed gate and blades.

Page 21: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

I- 900 :::> a.. ~ 800 0

I-' I- 700 CI'I l-

<! 3: 600 0 --' - 500 I-~

~

lOa.

80 ~ z

7J

I w t.)

a:: I

./Q w 60 ,;'

a.. ./ ,;' ..

>- ,;' t.) ,;' Z

w 40 ,;'

/ () "" " l1.. " l1...

W 20

o ~, ----~--~~----~--~~----~--~--------~~--------~----~ 150 200 250 300 350 400

T U RBI N E SP E ED, RPM

Fig. 6. Variable speed characteristics foraxia.l-flow turbine A2 (Ns 2.65 1 fixed gate and blades).

16.0

15.0 t.)

w I 4.0 (J)

......... If)

13.0 :E .. w

t 2. a C,!) a::: <!

11.0 ~ (J)

10.0 0

9.0

Page 22: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

I-' -..J 80

I-::> 0.. I-::> 60 0

l-I-« ~40 0 --.I

~

20

100

I- 80 z w u a:: w 0.. 60 .. r u z w

u 40

LL LL w

20 1

CONSTANT HEAD OPERATION

~.

-.

~ 35 0..

~

30 f() I 0

25 X

w 20 (!)

0:: « :r: u en

0

".."

p

o ~'----~--~------~--------~------~--------~------~------~ 350 400 450 500 550 600 650 700

TURB I NE SPEED, RPM

·F~g. 7. Variable speed characteristics for axial-flow'pump used as turbine (Ns 2.68, fixed gate and bl.ades) •

Page 23: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

100

~I(~ ..

>- 80 u z w u I.J.. I.J.. 60 w

I-' co ~ « w a.. I.J..

40 0

.-20~ z

w u a:: w a..

00

Fig. 8.

/ I\~ ~ AXIAL-FLOW TURBINE (N s =2.65)

FULL KAPLAN (FI XED SPEED)

) \ LOW HEAD PUMP OPERATED AS

AXIAL-FLOW TURBINE (N s =L61) TU RBI N E ( N s :: 2.68 )

20 40 60 80 100 120 140

PERCENT OF BEST EFF1CIENCY DISCHARGE, ~ Q

160

Off-design variable-speed performance of fixed-gate, fixed-blade propeller turbines Al A . ., 2' and Pl' Constant-speed Kaplan curve also shown for comparison.

Page 24: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

,l

obtained with turbines A2 and PI in telation to that for turbine Al

for which Q varies only slightly with n) is cleatly exhibited in this

figure. This may be related to the higher specific ,speed of turbines A2

and Pl' FiguteS indicates that the performance information supplied by

the manufacturers, related to fixed-speegoperation, is not sUfficiently

comprehensive to ,compute the full range of vadable speed performance. At

best, t\lrbines A2 and P 1 indicate a ±20 percent range in turbine dis­

charge with acceptable, performance / Which is much less than that which is

achieved by fixed vane, variable .... pitch blade turbines operating at con­

stant rotational speed. This operational range, however, m?iY be greater

in higher specific speed turbines.

NoW let us consider variable speed operation with a variable-gate

capability, such as turbines ll\, F 2' F 3' and Kl • Poin tslying along the

constant efficiency contours sketched in Fig. !) represent different com­

binations of H,Q values for constant speed, no' and different gate

,openings. Given any such contour, say n = nA, it is possible to obtain

the smallest discharge, such that for constant head H' B

(taken

equal to the best-efficienoy head in Fig. 9), the effioienoy ,n,A can be

achieved for Q = Q but not for any Q < QB' • , B This is simply done, by

following the similarity parabola (passing through the origin) tangent to

the contour n = n ,from H to HB" The speed" nB, is given' by 2 A ,A

nB = nA (HB/H,A) • The discharge Q13 may be read from Fig. 9 or determined

from the eguation Qs = QA n13/nA (see Eq. 7). In practice, this was done

by applying the simil-arity laws to all points on the curve n = nA and

finding the homologous valueS for H = HB• Point a then corresponds to

the minimum value of Q ,computed from the contour n = nA.'

The pedormance 'curves for the Francis turbines analyzed herein were

obtained from Bureau of Reclamation Monograph 20 (1976). For turbine F 3'

Fig. 33 of this reference shows typical head-discharge hill curves for a

range of N values (n=48 to 75 in English units)" An average valUe of s s n =62 is assumed herein. Figure 10, shows the results for a fixed gate s opening egual to 0.82 using the same procedure that was applied to the

data fo):' turbines Al , A2, and Pl " It is seen that Q is n.ow a decreasing

function of n"

19

Page 25: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

O·~~-L~~~~~~~~L-~~~~--~~~~~

o 0.2 0.4 0.6 0:8 1.0 1.2 1.4 1.6 1.8 Q/A

Q A A A A

Fig. 9. Variable-gate characteristic curves on H/H - Q/Q plane (H, Q: best efficiency values). .

20

Page 26: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

'")' e'

CONSTANT HEAD OPERATION I I

u 1,000 W

en ......

}- 100 ~

}-Z 1..1-W,

900 .. 0 w a::

80 t- Q (!)

W 0:: 8,000 r 0- <!

:c .. .~ " -1800 .~ N }- >-

I-' U :::> z 0- I " 0 }- w :::> 6,000 60 0 u

}- 1..1-}- ,1..1-« w ~ 4,000 40 ....I

:l<: 2,oool I "',p 20

150 175 200 225 250 275 300 325 TURB I NE SPEED, RPM

Fig. 10. Variable speed characteristics of Francis turbine F3 (Ns = 1.43 r fixed gate).

Page 27: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

This result. agrees with the calculations of Sheldon (1983), who found also

a decrease in Q with increasing n for three Francis turbines with ns values

(in English units)o;f 24.5, 44.7, and 56.1. Actually, Sheldon's resUlts show a

trend toward smaller variations in Q with n with increasing n: the tUr­s bine with ns = 56.1 exhibited practically no change in Q

rotational speed from 1.00 rpm t.o 160 rpm, while the unit with

with an inorease in

exhibited

a change in unit discharge from 0.85 cfs to about 0.55 cfsfor a change in speed

from 60 rpm to 130 rpm.

For turbines with variable gate, the prooedure outlined in the preoeding

paragraph is of more interest, since one would want to use the variable gateoapabil­

ity along with variable speed. The results obtained for the three Francis turbines

F1 , F2 , and F3 , and for the Kaplan turbine, Kl , are summarized in Table 1.

No CUrves are presented because the differences are small, as oan be seen from the

Table. This indicates that the variable speed capability would not significantly

improve the performanoe of these turbines at off-design flow and constant head.

Turbine

At g = 0.2 Q

= 0.4

:::: 0.6

= 0.8

= 1.0

== 1.2

TABLE 1. Comparison of Turbine Efficiencies for Fixed and Variable Rotational Speeds

Fl F2 F3

nvar speed/nfixed speed

74.0/74.0 75.1/75.0

85.3/85.0 83.7/83.2 82.0/81.3

91.2/91.0 89.5/89.2 89.3/88.9

92.2/92.2 92.0/92.0 92.0/92.0

86.0/86.0 90.1/90.1 89.8/89.8

Kl

83.8/83.5

90.5/90.0

91.5/91.0

92.0/92.0

91.5/91.5

Finally, the same variable'"'gate procedure was applied to a Bureau of

Reclamation pump turbine (1977), Tl • The results are shown in Figs. 11 and

12. It is seen that Q is now an inoreasing funotion ofn in b.oth the

turbining and pumping modes. There is significant improvement in turbine

22

Page 28: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

"" "

VARIABLE GATE CONSTANT HEAD OPERATION 100

TURBINE EFFICIENCY 90

u 80 w CJ)

I-"-rt) z

70 I- W lL. ()

0:: N .. w 60 w N

I a.. o .. x 50~ ~ 50

w 40 w 40 (!) () 0:: TURB l NE 0 I SCHARGE ./ ",­

~ 30[ ~. 30 u w Cf)

20 20 0

1:[ 10

0

Ji" BE P /

01 £':::::J PUMP

60 80 100 120 140 160 180 TURB I NE SPEED N, RPM

Fig. 11. Variable-speed characteristics of USBR pump turbine Tl (Ns = 0.76).

Page 29: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

N

"'"

100

I- 80 :2 W U a:: w a. 60

>­U Z w 40 u lL. lL. W.

20

o

r"

I I

/ /

20

o '""".

VARIABLE GATE ,CONSTANT HEAD OPERATION

/" /

/~

40 60

----VARIABLE SPEED OPERATION FIXED SPEED OPERATION

80 100 120 140

PERCENT OF BEST EFFICIENCY DISCHARGE, Q

Q Fig. 12. Variable and fixed-speed characteristics of USBR pump turbine Tl (Ns 0.76).

160

Page 30: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

(:

efficiency at off-design flow and constant head, even though the specific speed

of the unit is similar to turbine F 2' which experienced a very limited

efficiencY' improvement. The authors are not certain as to the reason for this

difference in results between units F2 and '1'1' Two possible reasons are:

1) That geometric shape of a pump-turbine runner is much closer to

that of a pump than a turbine. units F 2 and T 1 are therefore

likely to be asimilar geometries.

2) The pump-turbine unit may not have been designed for off-design

discharge at constant head, which would result in a very poor

constant speed efficiency curve.

25

Page 31: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

c'

Q

V. SOMETHEORETlCAL CALCULATIONS

The calculations in Section IV indicate that for constant H, the

discharge (0) appears to be a decreasing function of rotational speed (n)

at low specific speed (N s ) (Francis turbines), while for larger Ns

(~ial-flow turbines) 0 increases wtih increasing n. Within each tUr­

bine type this behavior depends on the characteristics of the individual

machines, so it may be possible to have different Q versus n relation­

ships for the l3ame value of N, depending on the specific design. In s

other words, one may be able to influence the speed dependence by l3uitable

design modifications. In this section, we examine briefly this problem in

the case of axial-flow turbines, for which a relationship O(n) can be

derived theoretically on the basis of certain parameters characterizing

the blade lattice geometry.

To introduce the calculations, we look first at the case of a reaction

turbine (not necessarily of the axial-flow type) with a sUfficient number

of blades so that the direction of the fluid flow at the exit from the runner

is tangential to the exit blade angle. We write Euler's equation in the

form

(8)

where H is the turbine net head, g is the acceleration of gravity, llh

is the turbine hydraulic effioiency, the subscripts 1 and 2 deno.te inlet to

exit fram the runner, respectively, V is the fluid velocity and V its

magnitude, a is the angle that the velocity vector V makes with the -+ rotational velocity u, and u + is the magnitude of u. In the space

between distributor .exit and runner inlet, one has, wi th sufficient approxi­

mation,

26

Page 32: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

(I

where r is radial distance and the subscript 0 denotes exit from the

distributor. We have, furthermore,

where bo is the ohannel width. ~hus,

Q 1 21tbor l tan ao

~hen from the exit velocity triang1e, one obtains

V2 cos a 2

+ where Sz is the angle that the runner blades make with the negative u 2

direot,ion, and A2 is the exit flow cross-sectional area. Combining Eg. (8)

and the last two equations, one gets,

(9)

where rG == rotational speed (rad/sec) = u/r.

~his equation shows that under the condi tiens stated, the dependence of

Q on n is of the form An + BTlh/n, where A and Bare oonstants. If

nh were constant when n varies (which it is not), the Q(n) graph would

be of the form of the curve labeled "Eq. (.14,) II in Fig. 13. The minimum of the,

curve oocur,s in this case where (r 2rG • ) 2 = nh(gH}, that is m /0, 2 m1n' min peak) '= nh(9H)/(r z20, k2), with rG, k 0:;:; best-efficiency or c1esign speed. Depending

, pea 'pea 2 ' on the value of the parameter gH/(r 2 rGpeak 2) (that is, of the parameter

, 2 2 gH/n P , with n = npeak )' the design point could be to the right or left of

the minimum, thus implying an ascending or descending Q(n) curve. In

practice, nh varies with n, and the actual Q(n) curve will depend on

the type of turbine and the characteristics of the specific design.

27

Page 33: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

(I

V.1. Axial-F.low Turbines

The above analysis is not applicable to axial-flow turbines because

the e~it fluid angle from the runner is not generally equal to ~2' In the

calculation that follows, this angle is first determined on the basis of the

blade lattice parameters. The presentation is kept brief and only the major

resulting equations are given here.

Consider a cylindrical section of the turbine of diameter d = aD, where

D is the runner diameter (a < 1). For this cylindrioal section, let t be

the blade spaoing in the lattice, 5/, the blade ohord length,

V the relative velocity and v its mOdulus, (3 the angle that the relative

velocity vector makes with the negative 0 direction, ~oo = (~l + ~2)/2, and

v = v = V the axial or meridional flow velocity. The subscripts 1 and 2 a a 00

again repres~nt the inlet and outlet of the runner, respectively. If we assume

irrotational flow, the magnitude of the lift force FL on each blade is given

by

(10 )

where r is the circulation around each blade in the lattice, given by

Using superposition, one can show that r can be e:xpressed in terms of the

zero-lift-angle, (30' for the lattice, and a dimensionless parameter 8, in

the form:

( 1.1)

Theparameter <5 represents the e:xtent to which the relative fluid velocity leaves

the runner at the runner's exit angle. Combining the last two equations, one obtains

= 1-.::...0 v 1 cos ~ 1 J. + 0 + " l' 1 . v~-

a 1 + 0 tansO

28

Page 34: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

a

This equation allow.s all components in the exit velooity triangle to

be expressed in terms of inlet quantities, specifically in terms of va

and a 1 , One has in partioular

=~ 1 + 8

and Euler's Eq. (8) then yields (with u l = u 2 = u)

(12)

Assuming a unifo):'m velocity distdbution ave):' the turbine cross section of

external diamete.r D and hub diameter dh , one has

(13)

Introducing u = ~O, where r .is the radius of the characteristic cylindri-

cal section considereo, ano replacing va from Eq. (13), one obtains., finally,'

from Eq. (12)

1 1 ---='-- + -....;;::-tan a l tan (30

(14 )

This equation oiffers fromEq. (9) mainly in the presence of the factor

(1 +8) /28 in the second term in the numerator, where 8 is the lattice

parameter defined earlier.

An alternative derivation of Eq. (14) Oan also be given on the' basis

of the head-correction factor eH as defined for example in Wislicenus (1965).

Euler's Eq •. (,8) with u1 = u 2 = u is written in the form

(15)

where the absolute velocity veotor 'V * 2 is that which would be obtained if;

the flow left the blade in the direction of zero lift, a* 2 is the angle

this vector makes with the t direction, and eH is the correction factor

29

Page 35: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

needed to make the righ-hand sides of Egs. (8) and (15) equal. One oan then

show that on the basis of CH as defined by Eg. (15) I the same Eg. (14)

is obtained with 20/(1 + 0) replaced by CH,

V.2. Estimation of the Lattice Parameter 0

\ ,:' In order to apply Eg. (14) to an aotual turbine it is necessary to

[

estimate the lattice paramete):'s 0 (0):' CH = 20/(1 +'0» and So' For

thin profiles with small mean-line curvatures, one can use as a first

approximation theoretical results available for a lattice of flat plates of

length L and spacing s, inclined at an angle So relative to the nega­

tive u direction. The lift coefficient for a plate in suoh a blade

system is given by (Durand, 1935)

C = 2'1TK sin a. L

(16)

where a. is the angle of attack and K is a factor that depends on the lattice

geometry, that is, a function of a = ,Q,/t (chord length divided by the

spacing) and the angle (30' Here, CL is defined by

where F' L

is the lift force per un·it width and p

fluid, Combining Egs. (17) and CtO} one has also

(l7)

the mass density of the

( 18')

and therefore the parameter 0 defined by Eg. (11)oan be calculated from the

results for the lift coefficient. One obtains

(19)

Likewise,

C . = __ ---'2=--__ _ H

1 + 2t 1 1 11,Q, sin (30 K

( 20)

30

\

Page 36: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

Graphs of 6 and CH as functions of So and cr;::: .Q./t are given respectively

in Mataix (1975) andWislicenus (1965).

V.3. Application to Axial-Flow Turbine A2

Available information on design cbaracteristics for the. axial-flow

turbine labeled A2 in Table 1, Section IV, bas been used to test Eq. (14).

'rbe information on hand was completed as needed, introducing suitable ....

assumptions. Known ~arameters were: diameter P ~ 1.8 m, head H = 8.3 m, 1\ A A 1\ .... 3

discharge Q;::: 10.65 m /s and speed n ~ 222 rpm (H, Q, and n are design or

peak-efficiency values).Tbe number of blades was z = 5. A peak efficiency .... n ;::: 0.90 was assumed for the machine. Application of Eq. (14) required

estimates of the hub diameter ratio dh/P, the radius r of a typical cylin­

drical section, and the various dimensions and angles in the velocity

triangles. These were obtained as~mming that the absolute velocity vector

at exit from the runner was perpendicular to the rotational velocity ii, that

is,

cos

V2,cos <:%2 "" 0,

Q',2 = VI cos <:%1'

and using Euler's equation to calculate VI cos <:%1 - V 2 '" Since v a

is.known from the known value of Q and the

assumed hub-diameter ratio (see Eq. 13), the velocity triangles for the cylin-

drical section at r could be drawn. The blade spacing and chord length

were estimated from the nt;lrober of blades, the r value chose"n, and available'

sketches of the turbine. Finally, Eq. (19) and Eq. (14), written for the

best-efficien.cy point,. were used to obtain reasonable estimates of So andS,

taking into account the value of S as determined from the velocity triangles. co

For the particular case of turbine A2, the following equation resulted

from these estimates

" 9 ~. 0.72£ + 0.3ln n " h n .Q n

( 21)

The values of fo,:' varying n were obtained from the available performance

curves for tbis turbine~ This equation is represented in Fig. 13. Also

'g.iven in Fig. 13 are the curve resulting from the similar ity ·calculations on

turbine AZ and a curve corresponding to Eq. (14) , with the numerical values

in 1!Jq. (21) , but with nh = 1.0 for all n values.

Finally, a tentative calculation to show what would be the effect of

varying certain characteristic design parameters of the turbine on the Q(n)

31

Page 37: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

W N

( .-:' "">

AX1AL-FLOW TURBINE A2 2.0 ,. ,

Q / Q 1.0

1\

5 BLADES, Q= J 0.65 m3 /SEC 1\ 1'\

H = 8.3 m, n = 222 REV /SEC

EQ. 14 ("1h = 1.0)·

EVALUATED ON THE BAS I S OF THE MACH I NElS PARA M ET E RS

SlMILARtTY CALCULATIONS

O'~---------------~--------------~--------------~----------~~ o 0.5 1.0 1\

n/n

1.5 2.0

Fig. 13. Variation of turbine discharge versus rotational speed from measured performance char­acter isticsand two analytical calculations (Eq. 14 and similarity calculations).

Page 38: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

\()

Q/" Q

1.10

1.0

0.30

8 = 0.26

8:: 0.32

8 =0.40

8=0.52

8 = 0.68

8 = 1 .00

8 = I. 00

8:: 0.68

8:: 0.52

8:: 0.40

8:: 0.32

8 = 0.26

0.80 0.5 I .0

n/~

1.5

Fig. 14. Effect of parameter, 8, on the variation of turbine discharge with rotational speed. Determined from theoretical calculations.

33

Page 39: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

dependence at constant H is presented in Fig. 14. The curves on this figure

are parametric in the parameter 8 defined by Eg. (11), and given by Eg. (19)

for the case of a lattice of flat plate ,profiles. Essentially, the variation

in 8 must be accomplished, as shown by Eg. (19), through variations in the

ratio r = ~/t or in the angle ~O' These results will be developed in more

detail elsewhere.

34

Page 40: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

(r)

'-,

VI. SUMMAR¥ AND CONCLUSIONS

1. The hydromechanical aspects of variable-speed hydroturbine operation

were investigated to estimate the potential improvement in performance

associated with the variable speed capability.

2. The potential advantages of the variable-speed turbine are a) improved

performance at off-design heads and improved range of operating head,

b) improved performance at off-design discharge, and c) improved per­

formance for pUmp-turbine units, where peak performance rotational

speed may be different for the pumping and turbining modes.

3. Variable-speed performance diagrams at constant head for two small

axial-flow turbines with fixed vanes and blades, an axial pump used

as a turbine, three Francis turbines, a pump turbine, and a Kaplan

turbine, were obtained from information supplied by manufacturers or

available in the literature. These performance diagrams were used

in conjunction with similarity laws to obtain the variable speed

performance characteristics at constant head operation.

4.. The calculations indicate a +20 percent range of turbine discharge at

oonstant head, with acceptable performanc~ for one of the axial flow

turbines with fixed vanes and blades and for the axial flow pump used

asa turbine. No significant performance improvement was found for

the other axial flow turbine. The turbines with a higher specific

speed had the greatest improvement in performance.

5. The variable speed capability did not significantly improve the performance

of the three Francis turbines at off-design discharge and constant head

when used along with the variable-gate capability of these turbines. The

same result was obtained for the Kaplan turbine.

35

Page 41: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

(

6. A significant improvement in turbining efficiency at off~design flow. and

constant head was found for the purnp~turbine, even though the specific

speed of the unit is similar to one of the Francis turbines disoussed

above.

o

Two possible reasons :Eor this di:Eference are:

':rhe geometr.io shape 0:E a pump~tuJ;bine runner is much oloser to

that of a pump than a turbine. ':rhe two units are there:Eore

likely to be asimilar geometries.

o r;rhe pump~turbine unit may not have been designed for off~design

disoharge at oonstant head, which would result ina very poor

constant speed e:E:Eiciency curve.

7. The dependence of turbine discharge, 0, on rotational speed, n, is

shown theoretically to be 0:E the form

where A and B are constants, and nh is the turbine hydraulic

efficiency. This implies an ascending or descending 0 versus n

curve, depending upon whether the design point of the turbine is to

the right or left .of the minimum in the above equation. For axial~f10w

(propeller) units, it is shown how the parameters A and Bdepend on the

design character istics.

8. The theoretical calculations confirm the variations of 0 with n· at

constant head for the propeller turbine e~hibiting the largest O(n)

changes. Furthermore, a tentative calculation is presented to show what

the effect of varying certain characteri.stic design parameters of the

turbine could be· on the O(n) dependence at oonstant head.

9. Additional r.esearch on variable speed turbine hydromechanics is needed,

on the one hand with more comprehensive data sets for· existing turbines, on

the other, to establish the feasibility of designing a turbine to achieve

variable~speed characteristics of possible interest. Improvements in per­

formance and ranges of application may be enhanced if a runner is specifically

designed for variable-speed operation.

36

Page 42: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

10 • Diffuser performance for high specific speeds needs reevaluation. At

high Ns diffuser efficiency is generally very important. The loss of

efficiency of propeller units at off-design speeds maybe offset by

improved diffuser efficiency. For variable .... speed turbines in particular,

e;x:cess swirl results at exit from the runner, which may be Qsed at least

v j partly to improve diffuser performance.

11. Cavitation characte):"istics of turbines as functions of speed need also

additional study. On a more general note, mo):"e model tests and turbine

resea):"ch need to be perfo):"med fo):" the public domain.

37

Page 43: f· · for variable head units, it may be possible to match the turbine rating with a ... ts for best conversion methods for wind-turbine, small hydro,

VII. REFERENCES

1. Alexander, G. C., "A case study of Francis turbine vat iable .... speed efficiency gain," presented at Workshop on Var iab1e Speed Generators -Hydro Applications, Denver, Colorado, May 1983~

2. Arndt, R. E. A., Fare11, C., and Wetzel, J., "Hydraulic turbines," in Small Hydro}?ower Systems Design, McGraw-Hill (in press).

3. Department of Energy and Electric Power Research Institute, Workshop on Variable Speed Generators - Hydro Applications, Denver, colorado, May 1983.

4. Durand, W. F., Aerodynamic TheorY, Vol. 4, Berlin, 1935.

5. Mataix, C., Turbomaquina~ Hidraulicas, Editorial Icai, Madrid, 1975.

6. Nair, R., "Development potential for low-head hydro," water Power and Dam Construction, December, 1982, pp. 49-56.

7. Sheldon, L. H., "An analysis of the benefits to be gained by using variable speed generators on Francis turbines," presented at Workshop on Variable ,Speed Generators, - Hydro Applications, Denver, Colorado, May 198.3.

8. Stelzer, R. S. and Walters, R. N., "Estimating reversible pump-turbine characteristics," Engineering Monogra2h No. 39, Bureau of Reclamation, December 1977.

,9. United states Bureau of Reclamation;, "Seleoting hydraulic reaction turbines, 11 Engineer in9 Monogra}?h No., 20 f 1976.

10. Wislicenus, G. F., Fluid Mechanics of Turbomachinery,' Vol. 1, Dover Publications, Inc., New York, 2nd Ed., 1965.

11. Wislicenus, G. F., "Hydrodynamic machinery," in Fluid Mechanics Research in Water Resources En9ineering, Proceedings, 40th Anniversary Sym20sium~ R.E.A. Arndt and M. March, ed., st~ Anthony Falls Hydraulic Laboratory, Dept. of, C'ivil and Mineral Engineering, univ. of Minnesota, Minneapolis, MN; April 1979. ' '

38