guia rapida i550 ethernet ip omron
TRANSCRIPT
![Page 1: Guia rapida i550 ethernet ip omron](https://reader034.vdocuments.pub/reader034/viewer/2022042500/58ee9a8c1a28ab2b728b4587/html5/thumbnails/1.jpg)
Guía rápida
Guía rápida ES
i550 Ethernet/IP OMRON CPU CJ2M
31/10/2016Fecha:
![Page 2: Guia rapida i550 ethernet ip omron](https://reader034.vdocuments.pub/reader034/viewer/2022042500/58ee9a8c1a28ab2b728b4587/html5/thumbnails/2.jpg)
![Page 3: Guia rapida i550 ethernet ip omron](https://reader034.vdocuments.pub/reader034/viewer/2022042500/58ee9a8c1a28ab2b728b4587/html5/thumbnails/3.jpg)
Contenido
Contenido
…………………….……..………………………………..……………… 4
...…….………………………………………………………………………………………………..……. 5
…………..……………………………………………………………..……………. 7
.……………..……………..……………………………………………………………………………………………………………….. 9
...……………………………………………………………………………………………………… 10
.…..………………………..………………………………………………………………………………….. 15
…………………………………………..………….………………………………………………… 17
.…..….…………………………..……………..………………………………………………………. 19
Material utilizado para las pruebas
Configuración i500
Descriptor eds – para OMRON
Eds
Configurador ETH/IP
CX-Programmer
Descripción de bytes
Modo ESPERA/RUN
3
![Page 4: Guia rapida i550 ethernet ip omron](https://reader034.vdocuments.pub/reader034/viewer/2022042500/58ee9a8c1a28ab2b728b4587/html5/thumbnails/4.jpg)
Material utilizado para las pruebas
• OMRON SYSMAC CJ2M CPU 31
• OMRON Network Configurator V3.59
• OMRON CX-Programmer V9.54
• LENZE i550 Ethernet/IP standard IO V03.00.02.00
• LENZE Easy Starter V1.10.0.0
Material utilizado para las pruebas
4
![Page 5: Guia rapida i550 ethernet ip omron](https://reader034.vdocuments.pub/reader034/viewer/2022042500/58ee9a8c1a28ab2b728b4587/html5/thumbnails/5.jpg)
Configuración i500
1. Habilitamos control por comunicaciones.
2. Habilitamos fuente de consigna por comunicaciones.
Configuración i500
5
![Page 6: Guia rapida i550 ethernet ip omron](https://reader034.vdocuments.pub/reader034/viewer/2022042500/58ee9a8c1a28ab2b728b4587/html5/thumbnails/6.jpg)
Configuración i500
3. Parametrizamos las condiciones de arranque y habilitación, según nuestras necesidades.
4. Tendremos que asignar la IP, via software, via switches o mediante herramienta BOOTP/DHCP server.
5. Salvamos parámetros.
6
![Page 7: Guia rapida i550 ethernet ip omron](https://reader034.vdocuments.pub/reader034/viewer/2022042500/58ee9a8c1a28ab2b728b4587/html5/thumbnails/7.jpg)
Descriptor eds – para OMRON
En caso de tener PLC Omron, utilizar los eds:
• i550_Speed_LEE
• i550_ExtendedSpeed_LEE
NOTA: En caso de usar PLC Allen Bradley se usará el eds disponible en nuestra página web.
Descriptor eds – para OMRON
7
![Page 8: Guia rapida i550 ethernet ip omron](https://reader034.vdocuments.pub/reader034/viewer/2022042500/58ee9a8c1a28ab2b728b4587/html5/thumbnails/8.jpg)
Eds
i550_Speed_LEE
Output – PLC i550
Input – i550 PLC
i550_ExtendedSpeed_Mode1_LEE
Output – PLC i550
Input – i550 PLC
Eds
W1 4008/1 NetWordIn1
W2 400B/3 Net Spd Stpnt Hz
W1 400A/1 NetWordOUT1
W2 400C/3 Actual Speed Hz
W1 4008/1 NetWordIn1
W2 400B/3 Net Spd Stpnt Hz
W3 4008/2 NetWordIN2
W1 400A/1 NetWordOUT1
W2 400C/3 Actual Speed Hz
W3 2DD8/0 Motor Current
W4 603F/0 Actual Fault
W5, W6 60FD/0 Dig Inputs Stat
8
![Page 9: Guia rapida i550 ethernet ip omron](https://reader034.vdocuments.pub/reader034/viewer/2022042500/58ee9a8c1a28ab2b728b4587/html5/thumbnails/9.jpg)
Configurador ETH/IP
1. Insertar tarjeta maestra y i550, usando el eds “i550_Speed_LEE”.
2. Registrar i500.
3. Crear TAGS.
Configurador ETH/IP
9
![Page 10: Guia rapida i550 ethernet ip omron](https://reader034.vdocuments.pub/reader034/viewer/2022042500/58ee9a8c1a28ab2b728b4587/html5/thumbnails/10.jpg)
Configurador ETH/IP
4. Realizar configuración.
10
![Page 11: Guia rapida i550 ethernet ip omron](https://reader034.vdocuments.pub/reader034/viewer/2022042500/58ee9a8c1a28ab2b728b4587/html5/thumbnails/11.jpg)
Configurador ETH/IP
5. Descargamos la configuración.
5. Generamos variables de red.
11
![Page 12: Guia rapida i550 ethernet ip omron](https://reader034.vdocuments.pub/reader034/viewer/2022042500/58ee9a8c1a28ab2b728b4587/html5/thumbnails/12.jpg)
CX-Programmer
1. Importamos las variables de red que hemos generado antes.
2. Una vez importadas las variables, les asignamos la dirección que nos interese.
3. Volcamos el proyecto.
CX-Programmer
12
![Page 13: Guia rapida i550 ethernet ip omron](https://reader034.vdocuments.pub/reader034/viewer/2022042500/58ee9a8c1a28ab2b728b4587/html5/thumbnails/13.jpg)
Descripción de bytes
Input – i550 PLC
Output – i550 PLC
Descripción de bytes
W1 400A/1 NetWordOUT1
W2 400C/3 Actual Speed Hz
1. W1 – Status Word.
2. W2 – Act. Speed.
3. Vacío, necesario para la configuración. No escribir.
1 2
3
W1 4008/1 NetWordIn1
W2 400B/3 Net Spd Stpnt Hz
1
2 3
4
1. Cabecera 32 bits. Escribir primer bit para pasar de modo ESPERA a RUN.
2. W1 – Ctrl. Word.
3. W2 – Speed stpnt.
4. Vacío, necesario para la configuración. No escribir.
13
![Page 14: Guia rapida i550 ethernet ip omron](https://reader034.vdocuments.pub/reader034/viewer/2022042500/58ee9a8c1a28ab2b728b4587/html5/thumbnails/14.jpg)
Modo ESPERA/RUN
En caso de tener el primer bit de la cabecera a FALSE, el i550 estará en modo STANDBY, mostrando mensaje “Inv. cyclic data [33171]”.
Poner a 1 el primer bit de la cabecera 32-bit, para que el variador empiece a aceptar comandos de control .
Modo ESPERA/RUN
1. Cabecera 32 bits. Escribir primer bit para pasar de modo ESPERA a RUN.
1
14