indelac product · pdf filespecifications: torque 100 lb-in (11.30 nm) cycle time 2.5...

48

Upload: nguyenhuong

Post on 06-Mar-2018

216 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard
Page 2: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

NOW OFFERING NET 30 DAYS AND 1% LATE FEE ON INTERNATIONAL TRANSACTIONS

QUICK AND EASY PAYMENTS USING VISA, MASTER AND AMERICAN EXPRESS CARDS

T O R Q U E S F R O M 1 0 0 L B - I N ( 1 1 N M ) T O 2 7 , 3 0 0 L B - I N ( 3 0 8 4 N M )

WHEN ORDERING PLEASE SPECIFY THE FOLLOWING:

1. QUANTITY REQUIRED

2. MODEL NUMBER OR SERIES

3. ENCLOSURE RATING

• NEMA TYPE 4 • NEMA TYPE 4X • NEMA TYPE 7 • NEMA TYPE 4 & 7

4. ELECTRICAL REQUIREMENTS

• VOLTAGE • HERTZ • PHASE

5. OUTPUT TORQUE

• ALLOW 25% SAFETY FACTOR

6. OPTIONAL EQUIPMENT REQUIRED

• OPTIONS ARE AVAILABLE FOR MOST APPLICATIONS, IF YOU HAVE QUESTIONS REGARDING THE APPLICATION PLEASE CONTACT OUR SALES SPECIALIST.

7. DESIRED SHIP DATE

• IF WE KNOW YOUR SCHEDULE WE WILL TRY TO MEET IT, IF WE DO NOT THE ORDER WILL DEFAULT TO OUR SCHEDULE.

US SALES

DEBBIE VOGES EXT: 100 [email protected]

I N T E R N A T I O N A L S A L E S

M A T T R O B I N S O N E X T : 1 0 9

M R O B I N S O N @ I N D E L A C . C O M

C U S T O M E R S E R V I C E

B O B K R A M E R E X T : 1 0 8 R K R A M E R @ I N D E L A C . C O M

P H O N E

1 - 8 5 9 - 7 2 7 - 7 8 9 0

T O L L F R E E P H O N E

1 - 8 0 0 - 6 6 2 - 9 4 2 4

F A X

1 - 8 5 9 - 7 2 7 - 4 0 7 0

A D D R E S S

6810 POWERLINE DR.

FLORENCE KY, 41042

USA

w w w . i n d e l a c . c o m

Page 3: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

2

Page 4: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

fter more then twenty five years of servicing the compact quarter

turn valve & damper automation industry ICI has maintained the goals

that inspired the companies beginning.

Mission Statement:

ICI’s mission is to manufacture a high quality electric actuator at a

reasonable cost in a timely fashion.

Quality Policy:

Our quality policy is to manufacture electric actuators that our customers

recognize to be of high quality at a price that is fair and reasonable.

The companies management team is committed to conformance to

corporate quality policy and to act as leaders in our efforts to meet our

quality goals.

Quality Objectives:

Indelac is committed to continual quality improvement of all operating

systems, products and services with our ultimate goal being zero defects

and total customer satisfaction. These goals will be implemented through:

- Total Quality Management (TQM)

- Advanced Employee Training (AET)

- Individual Responsibility (IR)

- Advancements in Designs, Production Control and Manufacturing

Technology (ADPCMT).

These operational standards, specifications, rejection parameters,

certifications, testing and inspection procedures will be our

guidelines to manufacture our products.

3

Page 5: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

4

Page 6: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

SPECIFICATIONS:

Torque 100 Lb-In (11.30 Nm)

Cycle time 2.5 seconds/90° 115Vac & 230Vac

3.0 seconds/90° 12Vdc, 24Vdc & 24Vac

Duty Cycle 25% standard 115Vac & 230Vac

75% 12Vdc, 24Vdc & 24Vac

Motor Permanent split capacitor

115Vac/1ph/50-6Hz standard

With thermal over load protection

L. R. Current 0.55 amps 115Vac, 0.38 amps 230Vac,

2.9 amps 12Vdc, 2.4 amps 24Vdc

Enclosure NEMA 4 standard, CSA certified

Coating Thermally bonded polyester powder

Fasteners Captive, 300 series stainless steel

Output ISO 5211 F03, F04 or F03/04

300 series stainless steel

Over Ride Manual, not declutching

Not available on DC voltage or NEMA 7

Brake Friction, standard

Position Ind. Visual indicator

Wired for light indication

Weight 6 Lbs.

Lubrication Permanent

Installation Universal

Temp. Range -40°F. to 150°F.

Heater & thermostat required 0°F. & below

Switches SPDT snap action

16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

5

2.87 (73)

4, 1/4-20 TAP, .44 (11.2) DP.1.9685 (50) B.C.

4, 10-24 TAP, .44 (11.2) DP.1.4173 (36) B.C.

1, 1/2-14 NPTCONDUIT ENTRY

4.13 (104.9)

5.75 (146.1)

2.39 (60.7)

4.72 (120)

1.31 (33.3)

ALLOW 2-1/2" ((63.5)FOR COVER REMOVAL

POSITIONINDICATOR

OPTIONALCONDUIT ENTRY

.25 (6.35)

.35 (9)

.39 (9.9)

MANUALOVER RIDE

1.47 (37.3)

45°

OPEN

REMOVE DOME TO ACCESSMANUAL OVER RIDE

4, .207 DIA HOLES, .563 DP.1/4-20 TAP, .44 DP.2.121 B.C.

4, .149 DIA HOLES .563 DP.10-24 TAP, .44 DP.1.653 B.C.

4.13

5.752.39

45°

.433

R Series F04 Mounting Pad

Page 7: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

SPECIFICATIONS:

Torque 100 Lb-In (11.30 Nm)

Cycle time 2.5 seconds/90° 115Vac

Duty Cycle 25% standard 115Vac

Motor Permanent split capacitor

115Vac/1ph/50-6Hz standard

With thermal over load protection

L. R. Current 0.55 amps 115Vac

0.38 amps 230Vac

2.9 amps 12Vdc

2.4 amps 24Vdc

Enclosure NEMA 7 not certified, Class I group C&D,

Class II group E, F & G Div. 1&2 Specifications

Output ISO 5211 F03

Position Ind. Visual indicator

Wired for light indication

Lubrication Permanent

Weight 8 Lbs

Installation Universal

Temp. Range -40°F. to 140°F.

Heater & thermostat required 0°F. & below

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

4, 1/4-20 TAP, .44 (11.2) DP.1.9685 (50)B.C.

4, 10-24 TAP, .44 DP.1.4173 (36) B.C.

1, 1/2-14 NPTCONDUIT ENTRY

ALLOW 2-1/2" (63.5) FOR COVER REMOVAL

POSITIONINDICATOR

OPTIONALCONDUIT ENTRY

.25 (6.4)

MANUALOVER RIDE

45°

OPEN

REMOVE DOME TO ACCESSMANUAL OVER RIDE

4.95 (125.7)

1.34 (34)

.89 (22.6)

6.06 (153.9)5.25 (133.4)

2.88 (73.2)

2.0 (50.8)

.433 (11)

6

Page 8: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

6.88 (174.8)2.0 (50.8)

4.25 (108)

2.88 (73.2)

ALLOW 3" (76.2) FORCOVER REMOVAL

5.39 (136.9)

1.0 (25.4)

1/2 NPT CONDUITENTRY

.63 (16)

1.75 (45.45)

OPTIONAL CONDUITENTRY

.55 (14)

4, 1/4-20 TAP, 0.44 (11.2) DP.1.969 (50) BC

45°

4, 5/16-18 TAP, .5 (12.7) DP.2.756" (70) BC.

2.43 (61.8)

POSITIONINDICATOR

TO MANUALLY OVER RIDEREMOVE BEACON AND ROTATESHAFT WITH 3/8'' (9.53) WRENCH

OPEN

4, 10-24 TAP, .44 (11.2) DP.1.4173 (36) B.C.

.91 (23.1)

DIMENSIONS (mm)

SPECIFICATIONS:

Torque 200 Lb-In (22.6 Nm) & 300 Lb-In (33.9 Nm)

Cycle time 5 seconds/90° 115Vac & 230Vac

10 seconds/90° with 75% duty cycle

9.0 seconds/90° 12Vdc, 24Vdc & 24Vac

Duty Cycle 25% standard 115Vac & 230Vac

75% optional

75% 12Vdc, 24V dc & 24Vac

Motor Permanent split capacitor

115Vac/1ph/50-60Hz standard

With thermal over load protection

L. R. Current 200 Lb-In 0.75 (22.6 Nm) amps 115Vac

300 Lb-In 0.99 (33.9 Nm) amps 115Vac

0.38 amps 230Vac

4.2 amps 12Vdc

3.2 amps 24Vdc

Enclosure NEMA 4 standard

CSA certified (CSAfile #LR79567)

Coating Thermally bonded polyester powder

Fasteners Captive, 300 series stainless steel

Output ISO 5211 F05

300 series stainless steel

Mounting Pad ISO 5211 F03, F05 & F07

Over Ride Manual, not declutching

Declutching manual over ride optional

DC voltage must be declutching

Brake Friction, standard

Position Ind. Visual indicator

Wired for light indication

Weight 10 Lbs.

Lubrication Permanent

Installation Universal

Temp. Range -40°F. to 150°F.

Heater & thermostat required 0°F. & below

Switches SPDT snap action

16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

7

Page 9: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

SPECIFICATIONS:

Torque 200 Lb-In (22.6 Nm) & 300 Lb-In (33.9 Nm)

Cycle time 5 seconds/90° 115Vac & 230Vac

10 seconds/90° with 75% duty cycle

9.0 seconds/90° 12Vdc, 24Vdc & 24Vac

Duty Cycle 25% standard 115Vac & 230Vac

75% optional

75% 12Vdc, 24Vdc & 24Vac

Motor Permanent split capacitor

115Vac/1ph/50-60Hz standard

With thermal over load protection

L. R. Current 200 Lb-In 0.75 (22.6 Nm) amps 115Vac

300 Lb-In 0.99 (33.9 Nm) amps 115Vac

0.38 amps 230Vac

4.2 amps 12Vdc, 3.2 amps 24Vdc

Enclosure NEMA 4 standard

Coating Thermally bonded polyester powder

Fasteners Captive, 300 series stainless steel

Output ISO 5211 F05

300 series stainless steel

Mounting Pad ISO 5211 F03, F05 & F07

Over Ride Not available

Brake Friction, standard

Position Ind. Visual indicator

Wired for light indication

Weight 14 Lbs.

Lubrication Permanent

Installation Universal

Temp. Range -40°F. to 150°F.

Heater & thermostat required 0°F. & below

Switches SPDT snap action

16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc

NOTE: 24Vac motors are 24Vdc motors rectified for use with

24Vac voltage.

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

45.0°

1/2-14 NPTCONDUIT ENTRY

4, 1/4-20 TAP .44 (11.2) DPON 1.968 BC

4, 5/16-18 TAP .5 (12.7) DP.ON 2.756 (70) BC

3.1 (78.7)

4.75 (120.7)

ALLOW 3" (76.2) FORCOVER REMOVAL

.55 (14)

4.75 (120.7)

7.34 (186.4)

6.88 (174.8)

.63 (16)

2.11 (53.6)

4, 10-24 TAP, .44 (11.2) DP.1.4173 B.C.

DIMENSIONS (mm)

8

Page 10: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

2.31 (58.7)

4, 1/4-20 TAP .44 (11.2) DP.1.969 (50) B.C.

1/2 N.P.T.CONDUITENTRY

8.53 (216.7) 9.41 (239)

8.66 (220)

7.78 (197.6)

3.13 (79.5)

3.2 (81.3)

OPTIONAL MANUAL OVER RIDE ANDPOSITION INDICATOR

6.39 (162.3)

1.39 (35.3)

.5 (12.7)

2.48 (63)

.63 (16)

ALLOW 4" (101.6) FORCOVER REMOVAL

.55 (14)STAR

OPTION #1ROTATE

THROUGH GEARS

OPTION #2DECLUTCHING WITH

HAND WHEEL

.38 (9.65)

POSITIONINDICATOR

OPEN

OPTION #3DECLUTCHING WITH

PUSH KNOB

.5 (12.7)

1.28 (32.5)

DIMENSIONS (mm)

9

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

Brake Friction, standard

Position Ind. Visual indicator, Wired for light indication

Weight 16 Lbs.

Lubrication Permanent

Installation Universal

Temp. Range -40°F. to 150°F.

Heater & thermostat required 0°F. & below

Switches SPDT snap action

16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc

SPECIFICATIONS:

Torque 200 Lb-In (23Nm) & 300 Lb-In (34Nm)

Cycle time 5 seconds/90° 115Vac & 230Vac

10 seconds/90° with 75% duty cycle

9.0 seconds/90° 12Vdc, 24Vdc & 24Vac

Duty Cycle 25% standard 115Vac & 230Vac

75% optional, 75% 12Vdc, 24Vdc & 24Vac

Motor Permanent split capacitor 115Vac/1ph/50-

60Hz standard with thermal over load

protection

L. R. Current 200 Lb-In (22.6 Nm) 0.75 amps 115Vac

300 Lb-In (33.9 Nm) 0.99 amps 115Vac

0.38 amps 230Vac, 4.2 amps 12Vdc,

3.2 amps 24Vdc

Enclosure NEMA 7 standard, CSA and UL certified

Coating Thermally bonded polyester powder

Fasteners 300 series stainless steel

Output ISO 5211 F05, 300 series stainless steel

Mounting Pad ISO 5211 F03, F05 & F07

Over Ride Manual, not declutching

Declutching manual over ride optional

DC voltage must be declutching

.5 (12.7)

1.28 (32.5)

Page 11: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

Output ISO 5211 F07

300 series stainless steel

Mounting Pad ISO 5211 F07

Over Ride Manual, declutching

Brake Friction, standard

Position Ind. Visual indicator

Wired for light indication

Weight 18 Lbs.

Lubrication Permanent

Installation Universal

Temp. Range -40°F. to 150°F.

Heater & thermostat required

0°F. & below

Switches SPDT snap action

16 amp ½ HP 125, 250Vac,

0.5amp 125Vdc

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

B

A

A

C

2.81 (71.4)

9.03 (229.4)

ALLOW 4'' (101.6) FORCOVER REMOVAL

1.76 (44.7)

.63 (16) 1/2" NPTCONDUIT ENTRY

4, 5/16-18 TAP .4 (10.2) DEEP2.756 (70) B.C.

MANUAL OVER RIDEPUSH AND ROTATE TO ENGAGE,PUSH A SECOND TIME TO DECLUTCH

VISUAL POSITIONINDICATOR

7.09 (180.1)

4, 3/8-16 TAP .56 (14.2) DEEP 4.015(102) B.C. MH ONLY

.67 (17)

OPEN

Model A B CML - MS 7.0 (177.8) 2.38 (60.5) 2.63 (66.8)MH 8.5 (215.9) 3.13 (79.5) 3.38 (85.9)DIMENSIONS IN INCHESDIMENSIONS (mm)

SPECIFICATIONS:

Torque 400 Lb-In (45.2 Nm) model MS

675 Lb-In (76.3 Nm) model MR

1000 Lb-In (113 Nm) model ML

1500 Lb-In (169 Nm) model MH

Cycle time MS 10 seconds/90° 115, 230Vac & 12Vdc

MS 20 seconds/90° 75% duty, 24Vdc & 24Vac

MR & ML 15 seconds/90° 115, 230Vac & 12Vdc

MR & ML 30 seconds/90° 75% duty, 24Vdc & 24Vac

MH 30 seconds/90° 115, 230Vac & 12Vdc

MH 70 seconds/90° 75% duty, 24Vdc & 24Vac

Duty Cycle 25% standard 115Vac & 230Vac

75% optional

75% 12Vdc, 24Vdc & 24Vac

Motor Permanent split capacitor

115Vac/1ph/50-60Hz standard

With thermal over load protection

L. R. Current 115Vac MS & MR= 0.75 amps

115Vac ML & MH= 0.99 amps

230Vac MS, MR, ML & MH=0.38 amps

12Vdc 4.2 amps

24Vdc 3.2 amps

Enclosure NEMA 4 standard, CSA and UL certified

Coating Thermally bonded polyester powder

Fasteners 300 series stainless steel

10

Page 12: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

3.13 (80)

8.50 (216)

2.81 (71)

9.0 (229)

ALLOW 4'' (102) FOR COVER REMOVAL

1.76 (44.7)

.63 (16)

.667 (17)

1/2" NPTCONDUIT ENTRY

4, 5/16-18 TAP .4 (10) DP.2.756 (70) B.C.

MANUAL OVER RIDEPUSH AND ROTATE TO ENGAGE, PUSHA SECOND TIME TO DECLUTCH

VISUAL POSITIONINDICATOR

7.1 (180)

8.5 (216)

OPTIONAL ADDITIONAL 1/2"NPT CONDUIT ENTRY

3.38 (86)

4, 3/8-16 TAP .56 (14)DP. 4.015 (102) B.C.

OPEN

2.2 (56)R .25 (8)

DIMENSIONS (mm)

Enclosure NEMA 7 standard, CSA certified

Coating Thermally bonded polyester powder

Fasteners 300 series stainless steel

Output ISO 5211 F07

300 series stainless steel

Mounting Pad ISO 5211 F07

Over Ride Manual, declutching

Brake Friction, standard

Position Ind. Visual indicator

Wired for light indication

Weight 20 Lbs.

Lubrication Permanent

Installation Universal

Temp. Range -40°F. to 150°F.

Heater & thermostat required

0°F. & below

Switches SPDT snap action

16 amp ½ HP 125, 250Vac,

0.5amp 125Vdc

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

SPECIFICATIONS:

Torque 400 Lb-In (45.2 Nm) model MS

675 Lb-In (76.3 Nm) model MR

1000 Lb-In (113 Nm) model ML

1500 Lb-In (169 Nm) model MH

Cycle time MS 10 seconds/90° 115, 230Vac & 12Vdc

MS 20 seconds/90° 75% duty, 24Vdc & 24Vac

MR & ML 15 seconds/90° 115, 230Vac & 12Vdc

MR & ML 30 seconds/90° 75% duty, 24Vdc & 24Vac

MH 30 seconds/90° 115, 230Vac & 12Vdc

MH 70 seconds/90° 75% duty, 24Vdc & 24Vac

Duty Cycle 25% standard 115Vac & 230Vac

75% optional

75% 12Vdc, 24Vdc & 24Vac

Motor Permanent split capacitor

115Vac/1ph/50-60Hz standard

With thermal over load protection

L. R. Current 115Vac MS & MR= 0.75 amps

115Vac ML & MH= 0.99 amps

230Vac MS, MR, ML & MH=0.38 amps

12Vdc 4.2 amps

24Vdc 3.2 amps

11

Page 13: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

4, 5/16 DRILL 13/16 (21) DP.3/8-16 TAP 5/8 (16) DP.4.015 (102) B.C.

4, 5/16 DRILL 13/16 (21) DP.5/16-18 TAP 5/8 (16) DP.2.756 (70) B.C.

10

3.75

10

1.12

1.19

.31

.875

2.5

MANUAL OVER RIDEHAND WHEEL

POSITIONINDICATOR

9.96

3/4-14 NPTCONDUIT ENTRY

DIA.

ACROSS FLATS

OPEN

ALLOW 6'' (152) TO REMOVE COVER

6.88 Ø 7HAND WHEEL

3.0

(22.23)

(28.5)

(76)

(254)

(95) (32.5)

(254)

(175)

(95)

(178)

(30)

(63.5)

(8)

(253)

45°

1.293.75

Mounting Pad Male double “D” shaft with 4.242 BC

Over Ride Manual, declutching

Brake Power Off, optional

Position Ind. Visual indicator

Wired for light indication

Weight 40 Lbs.

Lubrication Permanent

Installation Universal

Temp. Range -40°F. to 150°F.

Heater & thermostat required 0°F. & below

Switches SPDT snap action

16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

SPECIFICATIONS:

Torque LA…2000 Lb-In (226 Nm)

LX…3840 Lb-In (434 Nm)

Cycle time LA…12 seconds/90°

LX…14 seconds/90°

Duty Cycle Continuous

Motor Permanent split capacitor

115Vac/1ph/50-60Hz standard

With thermal over load protection

L. R. Current 115Vac LA= 1.50 amps (FL=0.98 amps)

115Vac LX= 2.90 amps

230Vac LA= .80 amps

230Vac LX=1.50 amp

12Vdc LA=4.93 amps

12Vdc LX=6.83 amps

Enclosure NEMA 4 standard, CSA certified

NEMA 7 optional, CSA certified

Coating Thermally bonded polyester powder

Fasteners 300 series stainless steel

Output ISO 5211 F07

300 series stainless steel

12

45

Page 14: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

12.9(328)

Ø 7.3 (185)

3.8

4.63 (118)

2.2

.13 (3.3)

5.44 (138)

5.3 (135)

B

14.0 (356)

45°

13.5 (343)

13.5 (343)

16 (406)

C DIA.

ALLOW 7" FORCOVER REMOVAL

POSITIONINDICATOR

3/4-14 NPT CONDUITENTRY

OPTIONALCONDUIT ENTRY

DECLUTCHINGMANUAL OVER RIDE

4, 5/8-11 TAP, 3/4 (19) DP.,5.5118 (140) B.C.

4, 3/8-16 TAP, .63 (16) DP.,4.242 (107.7) B.C.

MODEL A B C 5K 1.19 .875 1.13 (30) (22.2) (28)

7K, 12K & 14K 1.60 1.42 2.38 (41.6) (36.1) (60.5)DEMINSIONS (mm)

A

OPEN

(96.5) (56)

Over Ride Manual, declutching

Brake Power Off, optional

Position Ind. Visual indicator

Wired for light indication

Weight +110 Lbs.

Lubrication Permanent

Installation Universal

Temp. Range -40°F. to 150°F.

Heater & thermostat required 0°F. & below

Switches SPDT snap action

16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

SPECIFICATIONS:

Torque Model 5K=5000 Lb-In (565 Nm)

Model 7K=7020 Lb-In (793 Nm)

Model 12K=11520 Lb-In (1302 Nm)

Model 14K=14040 Lb-In (1586 Nm)

Cycle time 68 seconds/90°

Duty Cycle Continuous

Motor Permanent split capacitor

115Vac/1ph/50-60Hz standard

With thermal over load protection

L. R. Current 115Vac 5K=2.9 amps, 7K=4.1 amps

12K & 14K=7.1 amps

230Vac 5K= 1.5 amps, 7K=2.3 am

12K & 14K=3.8 amps

12Vdc 5K=4.93 amps, 7K=6.83 amps

24Vdc 5K= amps, 7K= amps

Enclosure NEMA 4 standard

NEMA 7 optional

Coating Thermally bonded polyester powder

Fasteners 300 series stainless steel

Mounting Pad Male double “D” shaft 300 series stainless steel

13

Page 15: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

MODEL 27K

12.88 (327.2)

3.75 (95.3)

4.62 (117.3)

2.19 (55.6)

13.52 (343.4)

13.5 (342.9)

16 (406.4)

ALLOW 7" (177.8) FORCOVER REMOVAL

3/4-14 NPT CONDUITENTRY

OPTIONAL CONDUITENTRY

DECLUTCHINGMANUAL OVER RIDE

8.0 (203.2)

CLOSE

OPEN

6.06 (153.9)

27.15 (689.6)

8.06 (204.7)

5.15 (130.8)5.31 (134.9)

18.81 (477.8)

CLOSE

OPEN

.625 (15.9)

Ø 7.50 (190.5)

1.457 (37.01)

8, 5/8-11 TAPPED HOLES, 1(25.4) DP.

BOTTOM VIEWMOUNTING DIMENSIONS

22.5°

45°

2.375 +.005/-.000

(60.33) BORE

KEYWAY

Mounting Pad 2.375’’ Bore

Over Ride Manual, declutching

Brake Power Off, optional

Position Ind. Visual indicator

Wired for light indication

Weight 170 Lbs.

Lubrication Permanent

Installation Universal

Temp. Range -40°F. to 150°F.

Heater & thermostat required 0°F. & below

Switches SPDT snap action

16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

SPECIFICATIONS:

Torque 27300 Lb-In (3084 Nm)

Cycle time 136 seconds/90°

Duty Cycle Continuous

Motor Permanent split capacitor

115Vac/1ph/50-60Hz standard

With thermal over load protection

L. R. Current 115vAC = 7.1 amps

230vAC = 3.8 amps

Enclosure NEMA 4 standard

NEMA 7 optional

Coating Thermally bonded polyester powder

Fasteners 300 series stainless steel

14

Page 16: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

3.13 (80)

8.5 (216)

2.81 (71)

ALLOW 4'' (101.6)FOR COVER REMOVAL

1.76 (44.7)

.63 (16)

.667 (17) 1/2" NPTCONDUIT ENTRY

4, 5/16-18 TAP .4 DP.2.756 (70) B.C.

VISUAL POSITION INDICATOR

7.1 (180)

8.5 (216)

OPTIONAL ADDITIONAL1/2" NPT CONDUIT ENTRY

3.38 (86)

4, 3/8-16 TAP .56 DP. 4.015 (102) B.C.

OPEN

MECHANICAL STOPFAIL CLOSE

DIMENSIONS (mm)

ICI’s model ES2 electric spring return actuator is a

light duty actuator designed for fail-safe

applications. It is recommended for applications

requiring system protection from unforeseen power

failures. This actuator is not recommended for

applications requiring several open/close cycles per

day.

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

OPTIONAL ADDITIONAL

1/2 NPT CONDUIT ENTRY

1/2 NPT

CONDUIT ENTRY

VISUAL POSITION INDICATOR

MECHANICAL STOP

FAIL CLOSED

ALLOW 4’’ FOR COVER REMOVAL

4, 3/8-16 TAP .56 DP.

4.015 B.C.

4, 5/16-18 TAP .40 DP.

2.756 B.C.

SPECIFICATIONS:

Torque 200 Lb-In (22.6 Nm)

Cycle time 10 seconds/90° 115 or 230Vac

Duty Cycle 5% standard 115Vac or 230Vac

Motor Permanent split capacitor

115Vac/1ph/50-60Hz standard

With thermal over load protection

L. R. Current 115Vac = 0.75 amps

230Vac = 0.38 amps

Enclosure NEMA 4 standard

NEMA 7 optional

Coating Thermally bonded polyester powder

Fasteners 300 series stainless steel

Output ISO 5211 F07

300 series stainless steel

Mounting Pad ISO 5211 F07

Brake Power on, standard

Position Ind. Visual indicator

Weight 24 Lbs.

Lubrication Permanent

Installation Universal

Temp. Range -40°F. to 150°F.

Heater & thermostat required 0°F. & below

Switches SPDT snap action

16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc

15

Page 17: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

3/4-14 NPTCONDUIT ENTRY

10.0 (254)

CF

3.75 (95)

D

E3.75 (95)

B

A

SPRING END TORQUEADJUSTING SCREW,SET AT FACTORY

SPRING END POSITIONADJUSTING SCREW,SET AT FACTORY

3.0 (76)

DIMENSIONS IN INCHES

MODEL A B C D E F G H

AS4 & 6 14.69 4.69 .75 15.66 5.06 2.0 .660 5.0 (373) (119) (19) (397.8) (128.5) (50.8) (16.76) (127)

AS10 15.06 4.88 1.0 17.0 5.88 2.5 1.0 6.0 (382.5) (124) (25.4) (431.8) (149.4) (63.5) (25.4) (152.4) (mm)

ALLOW 6" FORCOVER REMOVAL

CATALOG DRAWING FOR SPRING RETURNACTUATOR

ICIIndelac Controls, Inc. Florence, Ky. 41042

CD0605265-26-2006JLR

1" = 1"

AS4 & 6....4, 5/16-18 X 5/8" DP., 2.756 (70) B.C.AS10.........4, 1/2-13 X 5/8" DP., 4.010 (102) B.C.

2.0 (50.8)

G

6.25 (158.8)

SQUARE

H

10.0 (254)

45.0°

SPECIFICATIONS:

Torque AS4 400 Lb-In (45.2 Nm)

AS6 600 Lb-In (67.8 Nm)

AS10 1000 Lb-In (113 Nm)

Cycle time 12 seconds/90° 115 or 230Vac

Duty Cycle 25% standard 115Vac or 230Vac

Motor Permanent split capacitor

115Vac/1ph/50-60Hz standard

With thermal over load protection

L. R. Current 115Vac = 2.91 amps

230Vac = 2.40 amps

Enclosure NEMA 4 standard

NEMA 7 optional

Coating Thermally bonded polyester powder

Fasteners 300 series stainless steel

Output AS4 & AS6 ISO 5211 F07 = 0.66 Male

AS10 = 1.0” Male

Mounting Pad ISO 5211 F07

Brake Power on, standard

Weight AS4 & AS6 = 68 Lbs.

AS10 = 78 Lbs.

Lubrication Permanent

Installation Universal

Temp. Range -40°F. to 150°F.

Heater & thermostat required 0°F. & below

Switches SPDT snap action

16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc

ICI’s models AS4, AS6 & AS10 electric spring

return actuators are heavy duty actuators

designed for fail-safe applications. They are

recommended for applications requiring

system protection from unforeseen power

failures. These actuators are recommended for

applications requiring approximately 25

open/close cycles per day.

16

Page 18: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

1.13 (28.7)

.998 (25.35)

8.66 (220)

7.78 (197.6)

3.2 (81.28)

3.13 (79.5)

5.5 (127)

2.5 (63.5)

1.0 (25.4)STROKE

4.0 (101.6)

1.13 (28.7)

.998 (25.35)1.0 (25.4)STROKE

4.0 (101.6)

21.0 (533.4)

16.5 (419.1)

ALLOW 4" (101.6) FORCOVER REMOVAL

4, 1/4-20 TAP .44 (11.2) DP.2.756 (70) B.C.

45.0°

1/2 N.P.T.CONDUITENTRY TYP.

TWO POSITION SERIES12 LINEAR ACTUATOR1'' STROKE SHOWN

TWO POSITION SPRING RETURNSERIES 12 LINEAR ACTUATOR 1''STROKE SHOWN

1/2-20 TAP3/4 DP.

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

SPECIFICATIONS:

Thrust 280 Lb

Cycle time 3 IPM

Duty Cycle 75% standard 115Vac

Motor Permanent split capacitor

115Vac/1ph/50-60Hz standard

With thermal over load protection

L. R. Current 0.58 amps 115Vac

Enclosure NEMA 4 standard

Coating Thermally bonded polyester powder

Fasteners Captive, 300 series stainless steel

Output ISO 5211 F05

300 series stainless steel

Mounting Pad ISO 5211 F05

Brake Friction, standard

Power Off (optional)

Position Ind. Wired for light indication

Weight 16 Lbs. (as shown)

Lubrication Permanent

Installation Universal

Temp. Range -40°F. to 140°F.

Heater & thermostat required 0°F. & below

Limit Switches SPDT snap action (optional on 4-20mA control)

16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc

Feedback Pot. Linear (optional)

Positioner Analog 4-20mA (optional)

17

Page 19: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

Ø 1.3

9.58

3.33

2, 1/2-14 NPT CONDUITENTRIES

1.25

ACROSS FLATS(9.4mm)

1 3/4-12 UN-2ATHREAD

STROKE(25.4mm)

1/4-20 UNC-2A

ICI's linear CV series Control Valve actuators are equippedwith high resolution control boards, two 1/2'' NPT conduitentries, soft stop and end of position limit switches.

2.87

2.66

5.32

.32

OPTIONAL MANUAL OVER RIDECRANK HELD IN PLACE BY CLIP

MANUAL OVER RIDEACCESS NUT

.75.37

1.0

SOFT STOP FEATURE TOPROTECT VALVE SEAT

.49

7.68

(8.13mm)

( 243.3mm)

(195.1mm)

(31.8mm)

(19.1mm)

(8.5mm)

(33mm)

(12.5mm)

(67.6mm)

(135.1mm)

(mm) Dimensions in milimeters

(72.9mm)

SPECIFICATIONS:

Thrust 165 Lb

Cycle time 9.6 IPM

Duty Cycle 75% duty cycle

Motor Permanent split capacitor

115Vac/1ph/50-60Hz standard

With thermal over load protection

12 & 24Vdc available

L. R. Current 0.58 amps 115Vac

Enclosure NEMA type 4, 4X, 9 & 7 for Class I,

Groups C & D, Class II, Groups E, F

& G, Division 1 & 2

Hazardous Location.

Coating Thermally bonded polyester powder

Fasteners Captive, 300 series stainless steel

Output Drive 300 series stainless steel

Position Ind. 4-20mA optional

Weight 20 Lbs.

Lubrication Permanent

Installation Universal

Temp. Range -40°F. to 140°F.

Heater & thermostat required 0°F. & below

Limit Switches SPDT snap action (optional on 4-20mA control)

16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc

Feedback Pot. Linear

Positioner Analog 4-20mA

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

18

Page 20: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

19

(0° to 46° C).

Page 21: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

The above distances should be considered as maximums

Fail-Safe

Watts Actuator Series

Wire Gage Size

12 10 8 6 4

100

R 25ft 50ft 60ft 75ft 100ft

S, SD, MS & MR 20ft 40ft 50ft 65ft 85ft

SX & SDX 15ft 35ft 45ft 60ft 75ft

150 ML & MH 15ft 35ft 45ft 60ft 75ft

500 LA - - 20ft 35ft 50ft

LX & 5K - - 15ft 30ft 45ft

700 7K - - 10ft 25ft 40ft

1000 12K & 14K - - 10ft 25ft 40ft

20

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

Page 22: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

Indelac’s control panels are designed to provide

dependable operation as well as meet NEMA 4

specifications. While ICI offers a number of standard

control panels we also design special controls for

various applications. If your needs do not fall within

the realm of our standard control panels please call or

email your specifications for design consideration.

21

Page 23: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

22

Page 24: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

23

Page 25: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

Quarter

Turn

Actuator

Torque

(In/Lbs)

Torque

(Nm)

Cycle Time

(Sec./90 Deg.)

Lock Rotor

Current in

Amps for

115Vac

R 100 11.3 2.5 0.55

SD 200 22.6 5 0.75

SDX 300 33.9 5 0.75

SR 200 22.6 5 0.75

SX 300 33.9 5 0.75

MS 400 45.2 10 0.75

MR 675 76.3 15 0.75

ML 1000 113 15 0.75

MH 1500 170 30 0.75

LA 2000 226 12 1.5

LX 3840 434 14 2.9

5K 5000 565 68 2.9

7K 7020 793 68 7.1

12K 11520 1299.3 68 7.1

14K 14040 1586.3 68 7.1

27K 27300 3084.5 136 7.1

Spring

Return

Actuator

Torque

(In/Lbs)

Torque

(Nm)

Cycle Time

Power/Spring

Lock Rotor

Current in

Amps for

115Vac

ES2 200 22.6 10/2 0.75

AS4 400 45.2 12/3 1.5

AS6 600 67.8 12/4 1.5

AS10 1000 113 12/5 2.9

Steps To Create Model Number

1. Choose Actuator Series by Torque:

2. Enclosure

NEMA 4 = 4, NEMA 4X = 4X, NEMA 7 =

7, NEMA 4 & 7 = 4/7 (S, M, L, ES & AS)

3. Voltage

A=24Vac, B=115Vac, Z=115Vac Ext. duty

doubles cycle time, pertains to S & M series,

C=230Vac/1Ph, D=12Vdc, E=24Vdc,

G2=230V-3Ph, G3=380V-3Ph-50Hz,

G4=440-3PH, J=208Vac

Voltage symbol followed by an M designates

Metric tapped mounting holes.

4. Mounting Pad

R series=F03, F04 or F03/04, SR/SX=F05,

M series=F07 all others NA.

5. Cycle Time (See list)

* Fail Designation (Spring Return Only)

FC = Fail Close, FO = Fail Open.

OPTIONS: 6. Auxiliary Switch -S=1, -2S=2, -3S=3, -4S=4.

7. Manual over ride Standard on all NEMA 4 enclosures no symbol

required. Standard on K, L & M series NEMA 7

enclosure. M symbol required on M series only. S

series over ride with hand wheel. . M=Manual over ride

with push knob. Consult factory for availability on

spring return actuators.

8. Brake P=Power On Brake, P1=115V, P2=230V, P3=24Vac,

P4=12Vdc, P5=24Vdc Power Off Brake.

9. Potentiometer -1=Signal turn 1K, -1A= Dual signal turn 1K, -1B=Pot

with 3:1 ratio, -5K=Signal turn 5K.

10. Positioner VP=Modulating control 4-20mA, 0-10Vdc all voltages,

VQ=High resolution

NOTE: Actuators with output torque below

1500 lb-in are equipped with 25% duty cycle

motors, when used for modulating service

extended duty motors are supplied which

doubles the cycle time.

24

Page 26: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

11. Heater or Heater & Thermostat H=heater normally used for condensation, HT=heater &

thermostat used for temperature control

12. Breather BR normally used for condensation.

13. Speed Control SC used to increase standard cycle time.

14. Timer T allows repeat of open to close cycle at same time

every day.

15. Three Position -3P used for three positions control, i.e., 0, 90 & 180

deg., also for dribble control.

16. Light indication L green light to indicate open position & red light to

indicate close position.

17. Visual Indicator DI=Beacon, D=Pointer, Dome style indicator standard

on all actuators except SR, SX & AS series.

18. Transmitter -TX=4-20mA position transmitter.

19. Remote/Off/Local RL=Remote/off/local control panel with selector

switches and light indication.

20. Two Wire Control TW= Open/close control using relay (230Vac, 120Vac,

24Vac, 24Vdc or 12Vdc available).

21. Torque Sensor -TS electronic torque sensor (current sensor).

22. Multi-Turn -MT multiple revolutions.

23. Reversing Contact RC reversing control for DC & 3Ph. motors.

24. Transformer -TR control voltage transformer used on 3 Ph. motors.

25. Additional Conduit AC one additional conduit entry, not available on all

models.

26. Special Mounting PC special mounting pad configuration.

27. Mechanical Stop MS mechanical stop.

EXAMPLE: Electric actuator to deliver 1000 LB-IN torque, 120Vac, NEMA 7 enclosure, 2

auxiliary switches, heater & thermostat.

In the chart, find 1000 LB-IN torque, select model ML, straight across to the right find the cycle

time, 15sec/90 deg. Start down the selection list and pick out the items required for your

application and list them in the order they fall in, if an item is not selected merely ignore it. The

model number for our example would be: ML7B-15-2SHT

25

Page 27: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

R SD S M L K ES2 AS R SD S M L K ES2 AS

Enclosure NEMA Type 4X Speed Control 12Vdc

Type 4 NEMA Type 6 24Vdc

Standard NEMA Type 7 24Vac

NEMA Type 4 & 7 115Vac

Motor 115Vac Ext 'ed Duty 230Vac

Voltage 24Vac

115Vac 24Vdc T imer 12Vdc

Standard 12Vdc 24Vdc

208Vac/1ph/60Hz 24Vac

230Vac/1Ph/60Hz 115Vac

230Vac/3Ph 230Vac

380Vac3Ph/50Hz Multi-Position, Three Position

460Vac/3Ph Vac Four Position

Coating Epoxy Coating Multi-Position, Three Position

Anodize Vdc Four Position

Auxiliary One Position Diamond

Switches Two Indicator ICI Dome

Three Light Indication

Four 4-20mA Transmitter

Proximity Limit Three Position 3 3 3 3 3

Switches Two Auxiliary Power Supply 115Vac or 230Vac

Declutching NEME Type 4 1 1 1 Two Conduit NEMA Type 4

Man-O-Ride NEME Type 7 Entries NEMA Type 7

Brake, 12Vdc Mechanical Stop

Power On 24Vdc Breather

24Vac Heater

115Vac 1 1 Heater & Stat.

230Vac 1 1 Torque Sensor

Brake, 12Vdc Multi-Turn

Power Off 24Vdc Reversing DC Voltage

24Vac Contactor 3 Ph. Motors

115Vac T ransformer

230Vac 2 Wire Control 12Vdc

Potentiometer 1K, Single Turn 24Vdc

1K, Single Turn, Dual 24Vac

1K, 3:1 Ratio 115Vac

1K, 0 to 135 ohm 230Vac

1K, Ten Turn Remote Local

5K, Single Turn Control

Positioner 12Vdc & 24Vdc 2

24Vac 1. Standard equipment

115Vac 2 2. Assembled in SD enclosure

230Vac 2 3. Third party vendor

115Vac High Resolution

0-135 ohm

SERIES SERIES

OPTIONS OPTION

26

Page 28: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

27

Page 29: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

28

Page 30: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

1 2 3 4 5 6 7 8 9 10

N HOT

A.C.SUPPLYPOWER

PSC MOTOR

CAPACITOR

SW. #2

WIRING DIAGRAN FOR STANDARD1PH/60Hz/AC ELECTRIC ACTUATORILLUSTRATING SOME COMMON OPTIONS

JLR 5-19-99

990520

ICI Indelac Controls, Inc.

OPTIONALBRAKE

SW. #1 CLOSE LIMIT

SW. #2 OPEN LIMIT

SWITCH LAYOUT

OPTIONAL HEATER& THERMOSTAT

NO

NC

L

L

1 2 3 4 5 6 7 8 9 10

N HOT

A.C.SUPPLYPOWER DPDT CONTROL SWITCH

SHOWN FOR ILLUSTRATIONONLY

FIELD WIRING

PSC MOTOR

CAPACITOR SW. #1

JLR 5-19-99

990520

ICI

NOTES:POWER TO TERMINALS ONE & TWO OPENS THE VALVE(CCW ROTATION)POWER TO TERMINALS ONE & THREE CLOSES THE VALVE(CW ROTATION)TERMINALS 4 & 5 ARE FOR LIGHT INDICATION

WIRING DIAGRAM ILLUSTRATES THE ACTUATOR IN THEOPEN POSITION

GROUNDSCREW

OPTIONALBRAKE

SW. #1 CLOSE LIMIT

SW. #2 OPEN LIMIT

SWITCH LAYOUT

OPTIONAL HEATER& THERMOSTAT

C

NCNO

C

NO

L

L

LIGHTS FOR REMOTEPOSITION INDICATION

OPTIONAL EQUIPMENTFIELD WIRING

Two Position Actuator

1 2 3 4 5 6 7 8 9 10

N HOT

A.C.SUPPLYPOWER

DPDT CONTROL SWITCHSHOWN FOR ILLUSTRATIONONLY

FIELD WIRING

PSC MOTOR

CAPACITOR

SW. #2

SW. #1

WIRING DIAGRAN FOR TWO POSITION 1PH.ELECTRIC ACTUATOR ILLUSTRATINGSEVERAL COMMON OPTIONS

JLR 4-5-99

990405

ICI Indelac Controls, Inc.

NOTES:POWER TO TERMINALS ONE & TWO OPENSTHE VALVE (CCW ROTATION)POWER TO TERMINALS ONE & THREE CLOSESTHE VALVE (CW ROTATION)TERMINALS 4 THROUGH 9 FOR AUXILIARYSWITCHCONNECTIONS

WIRING DIAGRAM ILLUSTRATES THEACTUATOR IN THE OPEN POSITION

GROUNDSCREW

OPTIONALBRAKE

C NO NC C NO NC

OPTIONAL AUXILIARY SWITCHES

SW. #3 SW. #4

SW. #1 CLOSE LIMIT

SW. #2 OPEN LIMIT

SW. #3 CLOSE AUXILIARY

SW. #4 OPEN AUXILIARY

SWITCH LAYOUT

OPTIONAL HEATER &THERMOSTAT

WHT

BLK

BLK

RED

BLU

BLK

BLK

WHT

BLK

BLK

BLK

BLK

BLK BLK

BLKWHT

NO NC

C

NO NC

C

SWITCHNO.

CONTACTSWIRED

OPEN CLOSE

NO

NC

NO

NC

NO

NC

1

2

3

4NC

NO

MID

AUXILIARY SWITCHES (SW#3 & #4) MAY BE SET TO ANYDESIRED POSITION THROUGH OUT ACTUATOR TRAVEL

OPT.

OPT.

OPTIONAL EQUIPMENT

FIELD WIRING

Two Position Actuator with Brake, Two Auxiliary Switches, Heater & Thermostat

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

29

Page 31: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

1

5 8

4

129

13 14

CAMCAM

RELAY

1 2 3 4 5 6

DC MOTOR

SW.#1 SW.#2

POSITIVE NEGATIVE

ACTUATOR SHOWN IN THE OPENPOSITION

DC POWERSUPPLY

OPERATION:

SUPPLY POWER IS ALWAYS ON.

CONNECTION:SUPPLY POWER TO T1 & T2CONTROL VOLTAGE TO T3 & T4T5 & T6 SUPPLIED FOR LIGHT INDICATION.

ACTUATOR

FIELDWIRING

CONTROL SWITCH, FORILLUSTRATION ONLY

HEATER &THERMOSTATOPTIONAL

11-20-98 W981120

ICIIndelac Controls, Inc. Hebron, KY 41048

WIRING DIAGRAM FOR TWO POSITION DCACTUATOR WITH TWO WIRE CONTROL

JLR

OPTIONAL EQUIPMENTFIELD WIRING

15 8 4

129

13 14

CAM

CAM

RELAY

1 2 3 4

SW.#1

SW.#2

NEU. HOT

ACTUATOR SHOWN IN THE OPEN POSITION

1PH/60HZ AC POWERSUPPLY

ACTUATOR IS SHOWN IN THE OPEN POSITION

OPERATION:SUPPLY POWER IS ALWAYS ON.CONTROL IS THROUGH THE VENDOR SUPPLIED CONTROLDEVICE. (SHOWN HERE AS A SPST SWITCH)ACTUATOR SHOWN IN DIAGRAM IS WIRED FORNORMALLY CLOSE OPERATION. ACTUATOR OPENS WITHCONTACT CLOSURE OF CONTROL DEVICE. ACTUATORCLOSES WHEN CONTROL CONTACT IS OPENED.

CONNECTION:SUPPLY POWER TO T1 & T2CONTROL VOLTAGE TO T3 & T4TERMINALS T5 AND T6 FOR LIGHT INDICATION

ACTUATOR

FIELDWIRING

SPST CONTROL SWITCHFOR ILLUSTRATION ONLY

OPTIONALBRAKE

SW#1

SW#2

CLOSE SWITCH

OPEN SWITCH

HEATER &THERMOSTATOPTIONAL

5 6

GREENGROUNDSCREW

7-23-90 W900723

ICIIndelac Controls, Inc. Florence, KY 41042

WIRING DIAGRAM FOR TWO POSITION ACACTUATOR WITH TWO WIRE CONTROL

JLR

OPTIONAL EQUIPMENTFIELD WIRING

AC Actuator with 2 Wire Control

DC Actuator with 2 Wire Control

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

30

Page 32: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

1 2 3 4 5 6 7 8 9 10

SW#1 SW#2 SW#3 SW#4

SW.#4 CW

SW.#3 CCW

SW.#2 CW

SW.#1 CCW

60HZ/1PH/VACCONTROL SWITCHFOR ILLUSTRATIONONLY

NEU. HOT

OPERATION:POWER TO TERMINAL #1 & #2 POSITIONS SHAFT TO ZERO DEGREE "CCW ROTATION"POWER TO TERMINAL #1 & #3 POSITIONS SHAFT TO 180 DEGREE POSITION "CW ROTATION"POWER TO TERMINAL #1 & #4 POSITIONS SHAFT TO 90 DEGREE POSITION "CCW ROTATION"POWER TO TERMINAL #1 & #5 POSITIONS SHAFT TO 90 DEGREE POSITION "CW ROTATION"

TERMINALS 7, 8, 9 & 10 ARE FOR LIGHT INDICATION WHEN A LAMP IS CONNECTEDBETWEEN CONNECTION AND NEUTRAL.

DO NOT APPLY POWER TO TERMINAL #1 & #3 WITH ACTUATOR IN PODITION 'D', ACTUATORWILL OVER TRAVEL

FIELD WIRING

FIELDWIRING

12-18-96 W891101

SWITCH LAYOUT

PSC MOTOR

A

B C

D

BRN RED

CAPACITOR

BLK

BLK

BLK

BLK

NO

NC

C C C C

NO

NCNC

NO

NC

NO

WHT

BLU

RED

BLU

RED

YEL

ORG YEL

ORG

ICI Indelac Controls, Inc.

WIRING DIAGRAM FOR THREE POSITION 1PHELECTRIC ACTUATOR WITH SOME COMMON OPTIONS

JLR

115Vac Three Position Actuator

DCMOTOR

1 2 3 4 5 6 7 8 9 10

SW#2CW

SW#4CCW

SW#3CW

SW.#4

SW.#3

SW.#2

SW.#1

DC Voltage

CONTROLSWITCH

+ -

OPERATION:POWER TO TERMINAL #1 & #2 POSITIONS SHAFT TO ZERO DEGREE "CCW ROTATION"POWER TO TERMINAL #1 & #3 POSITIONS SHAFT TO 90 DEGREE POSITION "CW ROTATION"POWER TO TERMINAL #1 & #4 POSITIONS SHAFT TO 180 DEGREE POSITION "CW ROTATION"POWER TO TERMINAL #1 & #5 POSITIONS SHAFT TO 90 DEGREE POSITION "CCW ROTATION"

TERMINALS 7, 8, 9 & 10 ARE FOR LIGHT INDICATION WHEN A LAMP IS CONNECTED BETWEENCONNECTION AND NEUTRAL.

FIELD WIRING

FIELDWIRING

ICI Indelac Controls, Inc.

WIRING DIAGRAM FOR 12 & 24VDCTHREE POSITION ELECTRIC ACTUATOR

1-2-06 W060201

C C C

NO NO NO NONC NC NC NC

C

SW#1CCW

51 84

129

13 14

51

9

13 14

84

12

RED

BLK

ZERO DEGREES

180 DEGREES

90 DEGREES CW ROTATION

90 DEGREES CCW ROTATION

RED

RED

NOTE:RELAY CONNECTIONSNC = #1 & #4NO = #5 & #8 C = #9 & #12COIL = #13 & #14

51 84

129

13 14

RED

BLU

BLK

RED

YEL

BLK

ORG

YEL

RED

BLU

BLK

BLK

ORG

RED

BLK

BLK

BLK

RED BLK

51 84

129

13 14

RED

RED

RED

RED

BLK

BLK

RED

RED

BLK

BLK

0 90 180 90

JLR

Three Position DC Actuator

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

31

Page 33: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

1 2 3 4 5 6 7 8 9 1011 12

3 PHASE MOTOR

SW. #1 SW. #2 SW. #3 SW. #4

CAM CAM CAM CAM

SW. #1

SW. #2

SW. #3

SW. #4

CLOSE LIMIT SWITCH

OPEN LIMIT SWITCH

CLOSE POSITION AUXILIARY SWITCH

OPEN POSITION AUXILIARY SWITCH

L1 L2 L3

3 PHASE POWERSUPPLY

A. CONTROL VOLTAGE TRANSFORMERB. REVERSING CONTACTORC. HEATER & THERMOSTAT (OPTIONAL)

OPTIONAL EQUIPMENTFIELD WIRING

C NO

NC

C NO

NC

AUXILIARY SWITCHCONNECTIONS

ICIIndelac Controls, Inc. Florence, Ky. 41042

JLR 3-6-00

WIRING DIAGRAM FOR 3PH. ACTUATOR WITHREVERSING CONTACTOR, CONTROL VOLTAGETRANSFORMER & TWO AUXILIARY SWITCHES

SWITCH LAYOUT

BLU

BLK.

BLK.

WHT

FIELDWIRING

AUXILIARY SWITCHES

3 6 9

471

2 5 8

H1

H2

H3

H4

X2

X1

A

B

C

OPEN

CLOSE

OPTIONAL

W000306

RED

BLK

3 Phase with Reversing Contactor And Control Voltage Transformer

1 2 3 4

N HOT

A.C.SUPPLYPOWER

DPDT CONTROL SWITCHSHOWN FOR ILLUSTRATIONONLY

FIELD WIRING

PSC MOTOR

CAPACITOR

SW. #2

SW. #1

WIRING DIAGRAN FOR SPRING RETURNELECTRIC ACTUATOR WITH TWOAUXILIARY SWITCHES.

JLR 9-10-99

990910

I CI

Indelac Controls, Inc. Hebron, Ky. 41048

NOTES:POWER TO TERMINALS ONE & TWO OPENS THE VALVE(CCW ROTATION)POWER TO TERMINALS ONE & THREE CLOSES THE VALVE(CW ROTATION)TERMINAL 4 SUPPLIES 120V HOT TO BRAKE.TERMINALS 5 THROUGH 10 FOR AUXILIARY SWITCHCONNECTIONS

WIRING DIAGRAM ILLUSTRATES THE ACTUATOR IN THEOPEN POSITION

THIS IS A FAIL-SAFE ACTUATOR DO NOT USE INCONTROL TYPE APPLICATIONS

GROUNDSCREWBRAKE

OPTIONAL AUXILIARY SWITCHESSW. #1 CLOSE LIMIT

SW. #2 OPEN LIMIT

SW. #3 CLOSE AUXILIARY

SW. #4 OPEN AUXILIARY

SWITCH LAYOUT

NO

C

NC

NC

C

NO

HEATER &THERMOSTAT,OPTIONAL

REDBRN

BLK

4 5 6 7 8 9

C NO NC C NO NC

SW. #3 SW. #4

BLK

BLK

BLK

BLK

BLK BLK

OPTIONAL

FIELD WIRING

YEL

ORG

BLU

RED

Spring Return Actuators

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

32

Page 34: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

8 7 6 5 4 3 2 1 6 5 4 3 2 1 J1J2

4-20mA POSITIONER

PSC MOTORCAPACITOR

SW. 1, CLOSE

SW. 2, OPEN

SW.2

SW.1

BRAKEOPTIONAL

1PH-60HZPOWER SUPPLY

4-20mA CONTROLSIGNAL

0-10VDC or 0-5VDCCONTROL SIGNALREMOVE JP2, JP3 & JP4

1K OHM FEEDBACKPOTENTIOMETER

BLU

RED

WHT

BLK

BLK

BLK

WHT

FIELDWIRING

NHOT

-

+

+

ICI

Indelac Controls, Inc. W000203

JLR 2-3-00

NOTE:ACTUATOR SHIPPED IN OPENPOSITION, 20mA REPRESENTS OPENPOSITION. DO NOT ADJUST FEEDBACKPOTENTIOMETER OR LIMIT SWITCHESTHEY ARE FACTORY SET AND DO NOTREQUIRE CALIBRATION. TOCALIBRATE THE OPEN AND CLOSEPOSITION USE THE ZERO (4mA) ANDSPAN (20mA) TRIM POTENTIOMETERS.

TO CALIBRATE OPERATE ACTUATORTO CLOSE POSITION AND ADJUST WITHZERO TRIM POT THEN OPERAT TOOPEN POSITION AND SET USING SPANTRIM POT. NO FUTHER CALIBRATION ISNECESSARY.

HEATER &THERMOSTATOPTIONAL

WIRING DIAGRAM FOR 1Ph/60Hz ELECTRICACTUATOR WITH 4-20mA, 0-5Vdc OR 0-10Vdc CONTROL.

JP2

RED

GREEN

JP3

JP4

FUSE

DEADBAND

JP1

ZERO

SPANC

NO NC

C

NONC

JP2

RED

GREEN

JP3

JP4JP2

RED

GREEN

JP3

JP4 JUMPER SET FORFAIL OPEN UPONLOSS OF CONTROLSIGNAL

JUMPER SET FORFAIL CLOSE UPONLOSS OF CONTROLSIGNAL

JUMPER AS SHOWN BELOW IS FAIL INLAST POSITION UPON LOSS OF SIGNAL

GRN

RED

C

NO NC

C

NONC

9 10 11 12 13 14

SW. 3, CLOSE

SW. 4, OPEN

AUXILIARY SWITCHESOPTIONAL

SW.4SW.3

OPTIONAL EQUIPMENTFIELD WIRING

115V Modulating Actuator

1 2 3 4 5 6 7 8 910

BRUSH TYPEDC MOTOR+ -

4-20mA POSITIONER

+ _10 TO 30 VDCPOWER SUPPLY

+5V OUTPUT

0 to 5V OR 0 to 10V

4 to 20mA CONTROL SIGNAL

J1J2

POSITIONER SPECIFICATIONS:POWER REQUIREMENTS:Operating voltage....10 to 30 VDCOperating Current (motor on)....87mA typicalOperating Current (trip output on)....40mA typicalStandby Current (motor off, trip off)....20mA typicalFuse Type....8A, BUSSMANN ABC-8COMMAND SIGNAL INPUT:Common Mode Voltage (all inputs)....-13 to +30VDC0-5VDC....Input Impedance = 10K ohms, External Command Pot. = 1K ohm0-10VDC....Input Impedance = 20K ohms1-5VDC....Input Impedance = 200K ohms, Loss of signal threshold </=0.75V4-20mA....Input Impedance= 250 OHMS +/-1%, Loss of command signalthreshold </= 3mAFEEDBACK SIGNAL INPUT:Input Voltage....0 to 5VDC, External feedback pot. 1K to 10K ohmsDC MOTOR OUTPUTS:Maximum load current = 15A Locked rotor for 20 seconds typical.ENVIRONMENTAL:Operating Temp. = -40 to 65 deg. C, Storage Temp. = -40 to 85 deg. C.Relative Humidity Range = 0 to 90% (noncondensing)

ACTUATOR SHIPPED IN OPEN POSITIONUNLESS OTHERWISE SPECIFIED

WIRING DIAGRAM FOR DC ELECTRICACTUATOR WITH 4-20mA CONTROL

1-9-97

OPTIONAL HEATER (25Watt @ 68 Ohm) &THERMOSTAT (Required for applications below

0 deg. F.)

ZERO SPAN

THERMALOVER-LOADPROTECTION

1 2 3 4 5 6 7 8

JP5

JP1

JP2

JP3JP4

DEADBAND

FUSE

+

-

NOTE:LIMIT SWITCHES AND FEEDBACK POTENTIOMETER ARE SETAT THE FACTORY, CALIBRATIONS ARE NORMALLY NOTREQUIRED. TO CALIBRATE THE VALVE POSITION USE THEZERO & SPAN TRIM POTENTIOMETERS.

OPTIONAL EQUIPMENTFIELD WIRING

W970109DC

OPEN SW. CLOSE SW.

FIELD WIRING

1K POTENTIOMETER

ICI Indelac Controls, Inc.

JLR

12 & 24Vdc Modulating Actuator

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

33

Page 35: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

+ - DCMOTOR

CAM CAM

SW.#1

SW.#2

1 2 3 4 5 6

COIL

DC VOLTAGE

SPDT SWITCH SHOWN FORILLUSTRATION ONLY

REVERSING RELAY SUPPLIED BY CUSTOMER

-

+

FIELD WIRING

OPERATION:POWER TO 1 & 2 FOR CCW ROTATIONPOWER TO 3 & 4 FOR CW ROTATIONTERMINALS 5 & 6 FOR FIELD LIGHTINDICATION CONNECTION

SW.#1

SW.#2

SWITCH #1 OPEN SWITCHSWITCH #2 CLOSE SWITCH

ACTUATOR SHOWN INOPEN POSITION

10-4-2001

COM COM

NCNONCNO

C

NO NC

C

NO NC

W011004DC

ICIIndelac Controls, Inc. Florence, KY 41042

WIRING DIAGRAM FOR TWO POSITION S & RSERIES ELECTRIC ACTUATOR 12 OR 24VDC

JLR

FIELD WIRING

5 6

DC VOLTAGE

SPDT SWITCH SHOWN FORILLUSTRATION ONLY

-

+

FIELD WIRING

SW.#2 CLOSE SW.

SW.#1 OPEN SW.

ACTUATOR SHOWN INOPEN POSITION

ICIIndelac Controls, Inc. Florence, Ky. 41042

JLR 4-1-03

7 8 9 10C NO NC C NO NC

SW#3 OPTION SW#4 OPTION

SW.#3 CLOSE AUX. SW.

SW.#4 OPEN AUX. SW.

OPERATION:POWER TO 1 & 2 TO OPEN (CCW)POWER TO 1 & 3 TO CLOSE (CW)5, 6 & 7 AUX. SW. FOR CLOSE POSITION8, 9 & 10 AUX. SW. FOR OPEN POSITION

NOTE:AUXILIARY SWITCHES ARE OPTIONALACTUATOR IS AVAILABLE WITH ONE ORTWO AUXILIARY SWITCHES

+ - DCMOTOR

CAM CAM

SW.#1 SW.#2

1 2 3 4

COIL

REVERSINGRELAY9 12

4815

W030401

13 14

WIRING DIAGRAM FOR S SERIES WITH DCMOTOR, REVERSING RELAY & 2 AUXILIARYSWITCHES

Two Position DC Actuator

Two Position DC Actuator with Reversing Relay

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

34

Page 36: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

1 5 8 4

129

13 14

CAMCAM

RELAY

1 2 3 4 5 6

PSCMOTOR

SW.#1 SW.#2

NEU. HOT

ACTUATOR SHOWN IN THE OPEN POSITION

115V POWER SUPPLY

OPERATION:

CONNECTION:SUPPLY POWER TO T1 & T2T3 & T4 SUPPLIED FOR LIGHT INDICATION.

WHEN SPST SWITCH IS CLOSED THE ACTUATOR IS ACTIVATED ANDWILL OPEN AND CLOSE AS SET USING THE DIP SWITCHES ON THETIMER. THE CYCLE WILL REPEAT UNTIL POWER IS DISCONNECTED.

ACTUATOR

FIELDWIRING

3-26-02 W040204

2

1

3

SPST ON/OFF SWITCHSHOWN FOR ILLUSTRATIONONLY

BLK

BLK

WHT

TIMERYEL

ORG

WHT

BLU

RED

BLK BLK

GRN

RED

2 1 3

ONTIME

OFFTIME

OFF ON OFF ON

.1

.2

.4

.8

1.6

3.2

6.4

12.8

25.6

51.2

.1

.2

.4

.8

1.6

3.2

6.4

12.8

25.6

51.2

ADD ON TIME SELECTIONS6.3 SECONDS OR MINUTES

ADD ON TIME SELECTIONS21.6 SECONDS OR MINUTES

SECONDS/MINUTES

IN ADDITION TO ACTUATOR CYCLE TIME

TIMER

AVAILABLE SPEED OPTIONS:MODEL TIMINGCTBA12 ON .1 TO 102.3 SEC., OFF .1 TO 102.3 MIN.CTBA13 ON .1 TO 102.3 SEC., OFF 1 TO 1023 MIN.CTBA22 ON .1 TO 102.3 MIN., OFF .1 TO 102.3 MIN.CTBA23 ON .1 TO 102.3 MIN., OFF 1 TO 1023 MIN.CTBA33 ON 1 TO 1023 MIN., OFF 1 TO 1023 MIN.CTBA44 ON .25 TO 255.75 HRS., OFF .25 TO 255.75HRS.

ONTIME

OFFTIME

WIRING DIAGRAN FOR ELECTRIC ACTUATORWITH TIMER

ICI Indelac Controls, Inc.

JLR

CAPACITOR

7 108 9

FIELD WIRING

Actuator with Timer

1 2 3 4 5 6

N HOT

A.C.SUPPLYPOWER

DPDT CONTROL SWITCH SHOWNFOR ILLUSTRATION ONLY

FIELD WIRING

PSCMOTOR

CAPACITOR

SW.#2 SW. #1

WIRING DIAGRAN FOR A.C. ELECTRICACTUATOR WITH SPEED CONTROLILLUSTRATING SEVERAL COMMON OPTIONS

JLR 7-13-03

W030713

ICI

Indelac Controls, Inc. Florence, Ky. 41042

NOTES:POWER TO TERMINALS 1 & 2 OPENS THE VALVE (CCW ROTATION).POWER TO TERMINALS 1 & 3 CLOSES THE VALVE (CW ROTATION).TERMINALS #4 & #5 FOR LIGHT INDICATION.HOT TO TERMINAL 6 POWERS SPEED CONTROL.TERMINALS 7 THRUGH 10 FOR AUXILIARY SWITCH CONNECTIONS WHEN SUPPLIED.

WIRING DIAGRAM ILLUSTRATES THE ACTUATOR IN THE OPEN POSITION

OPTIONAL EQUIPMENT FIELD WIRING

GROUNDSCREW

OPTIONALBRAKE

SW. #1 CLOSE LIMIT

SW. #2 OPEN LIMIT

SWITCH LAYOUT

OPTIONALHEATER &THERMOSTAT

3

1

2

SPEEDCONTROL

NO NC

C

2 1 3

ONTIME

OFFTIME OFF ON OFF ON

.1

.2

.4

.8

1.6

3.2

6.4

12.8

25.6

51.2

.1

.2

.4

.8

1.6

3.2

6.4

12.8

25.6

51.2

ADD ON TIME SELECTIONS6.3 SECONDS OR MINUTES

ADD ON TIME SELECTIONS21.6 SECONDS OR MINUTES

SECONDS/MINUTES

IN ADDITION TO ACTUATOR CYCLE TIME

OPERATION: UPON APPLICATION OF POWER TOTERMINALS #1 AND #2 THE SPEED CONTROL PULSESPOWER TO THE ACTUATOR MOTER AS DETERMINEDBY THE SELECTION OF THE ON AND OFF TIME. ATTHE END OF TRAVEL THE LIMIT SWITCH TURNS OFFPOWER TO THE MOTOR. UPON APPLICATION OFPOWER TO TERMINALS #1 AND #3 THE SPEEDCONTROL AGAIN PULSES POWER TO THE MOTORUNTIL THE LIMIT SWITCH CUTS OFF THE POWER TOTHE MOTOR.

SPEED CONTROL

C

NO NC

AVAILABLE SPEED OPTIONS:MODEL TIMINGRS4A11 ON .1 TO 102.3 SEC., OFF .1 TO 102.3 SECRS4A12 ON .1 TO 102.3 SEC., OFF .1 TO 102.3 MINRS4A21 ON .1 TO 102.3 MIN., OFF .1 TO 102.3 SECRS4A22 ON .1 TO 102.3 MIN., OFF .1 TO 102.3 MIN

ONTIME

OFFTIME

Actuator with Speed Control

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

35

Page 37: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

NO NC

C

NO

C

NC NO NC

C

NO NC

C

OPEN

CLOSE

GRN

RED

1 2 3 4 5 6 7 8 9 10

N HOT

120Vac/60hz/1ph FROM POWER SUPPLY

ICI Indelac Controls, Inc.

WIRING DIAGRAM FOR CONTROLPANEL PBOC-10

JLR 5-24-05 W050524

1 2 3 4 5 6 7 8 9 10

GROUNDSCREW

ACTUATOR

1 2 3 4 5 6 7TERMINAL STRIP #2

TERMINAL STRIP #1

PBOC-10CONTROL

PSC MOTOR

BRAKEOPTIONAL

CAPACITOR AUXILIARY SWITCHES

CLOSE LIMITSWITCH

OPEN LIMITSWITCH

HEATER & THERMOSTATOPTIONAL

HEATER &THERMOSTATOPTIONAL

FIELD WIRING

FIELDWIRING

OPEN/CLOSEMECHANICALLYINTERLOCKEDMAINTAINEDPUSH BUTTON

BLK

BLK

WHT

8 9 10

NOTE:ACTUATORS WITHOUT AUXILIARYSWITCHES DO NOT REQUIRE HOTCONNECTED TO TERMINAL 4 TERMINALSTRIP #2 OF PBOC-10 CONTROL BOX.LIGHT INDICATION AT CONTROL BOX ISACCOMPLISHED BY CONNECTING T4 OFACTUATOR TO T5 (OPEN) TERMINAL STRIP#2 IN CONTROL BOX AND T5 IN ACTUATORTO T7 (CLOSE) TERMINAL STRIP #2 INCONTROL BOX.

OPTIONAL EQUIPMENTFIELD WIRING

3

6

9

2

5

8

1

4

7

B A

+

+

-

- -

+

NEU.

HOT

1 2 3 4 5 6

BATTERY INVERTER

CHARGER

ON/OFFSWITCH

RELAY

WHT

WHT

BLK

RED

BLK

BLK WHT

BLK

RED

BLK

BLK

BLK

WHT

1 2 3NEU

OPEN

CLOSE

ACTUATOR

FIELDWIRING

SPDT CONTROL SWITCH SHOWNFOR ILLUSTRATION ONLY

IC

IIndelac Controls, Inc. Florence, Ky. 41042

WIRING DIAGRAM FOR ELECTRICFAIL-SAFE DEVICE 120VAC-1PHSUPPLY POWER

8-15-03 JLR

GRN

NOTES:ACTUATOR SHOWN TO FAIL TO CLOSEPOSITION.

T1 = NEUTRALT2 = 120V-1PH SUPPLYT3 = NEUTRAL, OUTPUTT4 = 120V-1PH OUTPUT POWERT5 = 120V-1PH BACKUP POWERT6 = NOT USED

BACKUP POWER IS SQUARE SINE WAVE.

RED

ELECTRICFAIL-SAFEDEVICE

W030815FS

7 8 9 10

FIELD WIRINGOPTIONAL

NOTE:INVERTER SWITCH IS TURNED OFF DURINGSHIPMENT, TURN INVERTER SWITCH TO ONPOSITION OR SYSTEM WILL NOT OPERATECORRECTLY.

BLK HEATER &

THERMOSTATOPTIONAL

120VAC

SUPPLY

N HOT

Battery Back Up Fail-Safe Device

On/Off Control

ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070

36

Page 38: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

37

Page 39: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

38

Page 40: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

Torque (T) is any force about a given axis that produces rotation as a

moment. The magnitude of the moment is the product of the force (F) and

the perpendicular distance (D) from the line of action of the force to the axis,

T=F x D.

Simply put torque is generated by a twisting force which produces rotation

about an axis.

Torque conversions

Ft-Lb In-Lb Nm

1 12 1.36

5 60 6.80

10 120 13.60

20 240 27.20

40 480 54.40

80 960 108.80

100 1200 136.00

200 2400 272.00

400 4800 544.00

600 7200 816.00

800 9600 1088.00

1000 12000 1360.00

𝐹𝑡−𝐿𝑏 ∗ 12 = 𝐼𝑛−𝐿𝑏 𝐼𝑛−𝐿𝑏 ∗ .113 = 𝑁𝑚 𝐹𝑡−𝐿𝑏 ∗ 1.36 = 𝑁𝑚

39

Page 41: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

Duty cycle is the ratio of actuator on time to off time and is used to

determine the proper actuator for a specific application. It is also used to

determine an acceptable operating time so that the thermal over load in

the motor is not exceeded during valve or damper automation. Actuator

inefficiencies cause the motor temperature to rise and at a critical

temperature the thermal over load is activated and the actuator is shut

down. The actuator is inoperative (undesirable in most applications) for a

period of time allowing the motor to cool and the thermal over load to

reset. Duty Cycle = DC, On Time = ON and Off Time = OFF

DC = (ON/ON + OFF) x 100

For example: ICI’s standard model SD has a 5 second cycle time and is

rated at 25% duty cycle. This means that the off time must be at least 15

seconds, hence: ON = 5, OFF = 15

DC = (5/5+15) x 100

DC = (5/20) x 100

DC = 0.25 x 100

DC = 25%

Model SD with an extended duty motor has a 10 second cycle time and is

rated at 75% duty cycle. This means that the off time must be at least

3.333 seconds, hence: ON = 10, OFF = 13.333

DC = (10/10+3.333) x 100

DC = (10/13.333) x 100

DC = 0.75 x 100

DC = 75%

This formula can be used to determine the off time of an actuator if the

cycle time and duty cycle are known. OFF = (ON/DC)-ON

40

Page 42: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

ICI manufactures compact quarter turn electric actuators. The word

compact defines the torque range below 10,000 lb-in (1130 Nm). While

we do offer larger torque actuators and different style actuators like

multi-turn actuators (actuators rotating more than 360 degrees) and linear

actuators (actuators drive that move axially instead of rotary) our niche is

in the compact quarter turn market. ICI actuators are used for on-off

service (valve operated to full open/close position to start or stop flow) as

well as modulating service (valve positioned to throttle or regulate flow).

In the electric actuator world a limit switch is the device that controls the

end position of the actuator, the actuator limits. This term is often

confused with a limit switch that is used on pneumatic actuators to

transmit valve position. When using electric actuators the “pneumatic

limit switch option” is known of as auxiliary switches, extra limit

switches or auxiliary limit switches. Contrary to pneumatic actuators

where the limit switch is mounted externally with an electric actuator the

auxiliary limit switches are installed inside the actuator enclosure.

Actuator limits for compact quarter turn electric actuators are normally 0

(closed) and 90 (open) degrees.

ICI electric actuators are equipped with manual over rides. A manual

over ride allows the user to rotate the valve manually in the event of a

power failure. Our 400 lb-in (45.2 Nm) actuators and larger are equipped

with declutching manual over rides. Declutching manual over rides

disengage from the gear train enabling the user to turn the valve with

greater ease.

ICI also manufactures a line of electric fail-safe devices which are battery

back up systems that invert 12Vdc battery power to 115Vac square sine

wave power upon unexpected loss of main supply power allowing

standard actuators to operate valves open or close in an emergency.

41

Page 43: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

42

Page 44: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

ISO 5211:2001(E)

The a dimensions below were taken from the International Standard ISO

5211 First edition 2001-02-15 and are only a small representation of the

information available in International Standard ISO 5211.

Flange Type Female Drive Bolt Circle

F03 9mm (.354" Sq.) 36mm (1.417" Sq.)

F04 11mm (.433" Sq.) 42mm (1.654" Sq.)

F03/F04 (Not an ISO Flange) 9mm (.354" Sq.) 42mm (1.654" Sq.)

F05 14mm (.551" Sq.) 50mm (1.969" Sq.)

F07 17mm (.669" Sq.) 70mm (2.756" Sq.)

F10 22mm (.866" Sq.) 102mm (4.016" Sq.)

F12 27mm (1.063" Sq.) 125mm (4.921" Sq.)

F14 36mm (1.417" Sq.) 140mm (5.512" Sq.)

F16 46mm (1.811" Sq.) 165mm (6.496" Sq.)

F25 55mm (2.165" Sq.) 254mm (10.000" Sq.)

F30 75mm (2.953" Sq.) 298mm (11.732" Sq.)

43

Page 45: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

TYPE 1 General purpose intended for indoor use to prevent accidental

contact with enclosed equipment.

TYPE 4 Water and dust tight intended for indoor or outdoor use to

protect enclosed equipment from splashing water, seeping of,

falling or hose directed water and severe external

condensation, they are sleet proof.

TYPE 4X Water and dust tight with same provisions as Type 4 enclosure

but also are corrosion resistant.

TYPE 6 Water and dust tight sleet resistant intended for indoor or

outdoor use where occasional submersion may be

encountered with a static head of no more then 6 feet for no

longer then 30 minutes.

TYPE 7 Class I, Division 1 and 2, Groups A, B, C or D intended for

indoor hazardous locations. Division 1: Hazardous vapors are

present. Division 2: Hazardous contained but may not be

present. Groups A, B, C & D classifies different gases and vapors.

TYPE 9 Class II, Division 1 and 2, Groups E, F or G intended for

indoor hazardous locations. Division 1: Air suspended dust.

Division 2: Surface accumulated non-air suspended. Groups E,

F & G classifies different dust types.

IP Code Minimum NEMA

Enclosure Rating

I P 6 5 4 , 4 X

I P 6 7 6

I P 6 8 6 P

44

Page 46: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

Epoxy Hybrid Aromatic

Urethane

Aliphatic

Urethane

TGIC

Polyester

Polyester

Wrinkle

Non-TGIC

Polyester

Hardness

Flexibility

Overbake Stability

Exterior Durability

Corrosion Protection

Chemical/Solvent Resistance

Ease of Application

Not Good Fair Good Very Good Best

45

The powder coating used on all ICI electric actuators must:

1. Be Corvel Royal Blue #20-5005 or equivalent.

2. Be TGIC Polyester

3. Have excellent gloss pretension.

4. Provide excellent adhesion.

5. Provide good edge coverage and chip resistance.

6. Provide excellent exterior durability and resistance to the

suns UV rays.

7. Provide good salt spray protection.

8. Provide flexibility and hardness to assure protection

against high impact.

9. Offer a high degree of resistance to corrosion.

10. Offer a high degree of protection against chemicals and

solvents.

*The binder is the all important solid material that forms the

bulk of the powder coating. The above graphic representation

gives the relative properties of some common powder binder

types.

Page 47: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

Note: 24Vac units are 24Vdc motors rectified for 24Vac use.

FL=Full Load Current, LR=Lock Rotor Current

12Vdc 24Vdc 24Vac 115V-1Ph 230V-1Ph 230V-3Ph 460V-3Ph

Model FL LR FL LR FL LR FL LR FL LR FL LR FL LR

R 0.6 2.9 0.4 2.4 0.4 2.4 0.55 0.38 N/A N/A N/A N/A

SR 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A

SX 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A

SD 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A

SDX 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A

MR 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A

MS 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A

ML 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A

MH 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A

LA 6.9 48 3.7 25 3.7 25 0.98 1.5 1.03 2.4 N/A N/A N/A N/A

LX 6.9 48 3.7 25 3.7 25 1.09 2.9 1.03 2.4 N/A N/A N/A N/A

5K 6.9 48 3.7 25 3.7 25 1.09 2.9 1.03 2.4 1.26 4.3 0.5 1.9

7K 6.9 48 3.7 25 3.7 25 2.8 7.1 1.03 2.4 1.26 4.3 0.5 1.9

12K 2.8 7.1 1.03 2.4 1.26 4.3 0.5 1.9

14K 2.8 7.1 1.03 2.4 1.26 4.3 0.5 1.9

27K 2.8 7.1 1.03 2.4 1.26 4.3 0.5 1.9

46

Page 48: Indelac Product  · PDF fileSPECIFICATIONS: Torque 100 Lb-In (11.30 Nm) Cycle time 2.5 seconds/90° 115Vac & 230Vac 3.0 seconds/90° 12Vdc, 24Vdc & 24Vac Duty Cycle 25% standard

ORDERING INFORMATION WHEN ORDERING PLEASE SPECIFY THE FOLLOWING:

1. QUANTITY REQUIRED

2. MODEL NUMBER OR ACTUATOR SERIES

3. ENCLOSURE RATING

• NEMA TYPE 4

• NEMA TYPE 4X

• NEMA TYPE 7

• NEMA TYPE 4 & 7

4. ELECTRICAL REQUIREMENTS

• VOLTAGE

• HERTZ

• PHASE

5. OUTPUT TORQUE

• ALLOW 25% SAFETY FACTOR

6. OPTIONAL EQUIPMENT REQUIRED

• OPTIONS ARE AVAILABLE FOR MOST APPLICATIONS,

IF YOU HAVE QUESTIONS REGARDING THE

APPLICATION PLEASE CONTACT OUR SALES

SPECIALIST.

7. DESIRED SHIP DATE

• IF WE KNOW YOUR SCHEDULE WE WILL TRY TO MEET

IT, IF WE DO NOT THE ORDER WILL DEFAULT TO OUR

SCHEDULE.

ICI SALES TEAM

US SALES

DEBBIE VOGES EXT: 100

[email protected]

INTERNATIONAL SALES

MATT ROBINSON EXT: 109

[email protected]

CUSTOMER SERVICE

BOB KRAMER EXT: 108

[email protected]

GENERAL CONTACT

PHONE

1 - 8 5 9 - 7 2 7 - 7 8 9 0

TOLL FREE PHONE

1 - 8 0 0 - 6 6 2 - 9 4 2 4

FAX

1 - 8 5 9 - 7 2 7 - 4 0 7 0

ADDRESS

6810 POWERLINE DR.

FLORENCE KY, 41042

USA

VISIT US ONLINE!

w w w. i n d e l a c . c o m

RECOMMENDED SPARE PARTS

1. One set of limit switches.

2. Capacitors for R through M Series.

3. Potentiometer for modulating actuators.