indelac product · pdf filespecifications: torque 100 lb-in (11.30 nm) cycle time 2.5...
TRANSCRIPT
NOW OFFERING NET 30 DAYS AND 1% LATE FEE ON INTERNATIONAL TRANSACTIONS
QUICK AND EASY PAYMENTS USING VISA, MASTER AND AMERICAN EXPRESS CARDS
T O R Q U E S F R O M 1 0 0 L B - I N ( 1 1 N M ) T O 2 7 , 3 0 0 L B - I N ( 3 0 8 4 N M )
WHEN ORDERING PLEASE SPECIFY THE FOLLOWING:
1. QUANTITY REQUIRED
2. MODEL NUMBER OR SERIES
3. ENCLOSURE RATING
• NEMA TYPE 4 • NEMA TYPE 4X • NEMA TYPE 7 • NEMA TYPE 4 & 7
4. ELECTRICAL REQUIREMENTS
• VOLTAGE • HERTZ • PHASE
5. OUTPUT TORQUE
• ALLOW 25% SAFETY FACTOR
6. OPTIONAL EQUIPMENT REQUIRED
• OPTIONS ARE AVAILABLE FOR MOST APPLICATIONS, IF YOU HAVE QUESTIONS REGARDING THE APPLICATION PLEASE CONTACT OUR SALES SPECIALIST.
7. DESIRED SHIP DATE
• IF WE KNOW YOUR SCHEDULE WE WILL TRY TO MEET IT, IF WE DO NOT THE ORDER WILL DEFAULT TO OUR SCHEDULE.
US SALES
DEBBIE VOGES EXT: 100 [email protected]
I N T E R N A T I O N A L S A L E S
M A T T R O B I N S O N E X T : 1 0 9
M R O B I N S O N @ I N D E L A C . C O M
C U S T O M E R S E R V I C E
B O B K R A M E R E X T : 1 0 8 R K R A M E R @ I N D E L A C . C O M
P H O N E
1 - 8 5 9 - 7 2 7 - 7 8 9 0
T O L L F R E E P H O N E
1 - 8 0 0 - 6 6 2 - 9 4 2 4
F A X
1 - 8 5 9 - 7 2 7 - 4 0 7 0
A D D R E S S
6810 POWERLINE DR.
FLORENCE KY, 41042
USA
w w w . i n d e l a c . c o m
2
fter more then twenty five years of servicing the compact quarter
turn valve & damper automation industry ICI has maintained the goals
that inspired the companies beginning.
Mission Statement:
ICI’s mission is to manufacture a high quality electric actuator at a
reasonable cost in a timely fashion.
Quality Policy:
Our quality policy is to manufacture electric actuators that our customers
recognize to be of high quality at a price that is fair and reasonable.
The companies management team is committed to conformance to
corporate quality policy and to act as leaders in our efforts to meet our
quality goals.
Quality Objectives:
Indelac is committed to continual quality improvement of all operating
systems, products and services with our ultimate goal being zero defects
and total customer satisfaction. These goals will be implemented through:
- Total Quality Management (TQM)
- Advanced Employee Training (AET)
- Individual Responsibility (IR)
- Advancements in Designs, Production Control and Manufacturing
Technology (ADPCMT).
These operational standards, specifications, rejection parameters,
certifications, testing and inspection procedures will be our
guidelines to manufacture our products.
3
4
SPECIFICATIONS:
Torque 100 Lb-In (11.30 Nm)
Cycle time 2.5 seconds/90° 115Vac & 230Vac
3.0 seconds/90° 12Vdc, 24Vdc & 24Vac
Duty Cycle 25% standard 115Vac & 230Vac
75% 12Vdc, 24Vdc & 24Vac
Motor Permanent split capacitor
115Vac/1ph/50-6Hz standard
With thermal over load protection
L. R. Current 0.55 amps 115Vac, 0.38 amps 230Vac,
2.9 amps 12Vdc, 2.4 amps 24Vdc
Enclosure NEMA 4 standard, CSA certified
Coating Thermally bonded polyester powder
Fasteners Captive, 300 series stainless steel
Output ISO 5211 F03, F04 or F03/04
300 series stainless steel
Over Ride Manual, not declutching
Not available on DC voltage or NEMA 7
Brake Friction, standard
Position Ind. Visual indicator
Wired for light indication
Weight 6 Lbs.
Lubrication Permanent
Installation Universal
Temp. Range -40°F. to 150°F.
Heater & thermostat required 0°F. & below
Switches SPDT snap action
16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
5
2.87 (73)
4, 1/4-20 TAP, .44 (11.2) DP.1.9685 (50) B.C.
4, 10-24 TAP, .44 (11.2) DP.1.4173 (36) B.C.
1, 1/2-14 NPTCONDUIT ENTRY
4.13 (104.9)
5.75 (146.1)
2.39 (60.7)
4.72 (120)
1.31 (33.3)
ALLOW 2-1/2" ((63.5)FOR COVER REMOVAL
POSITIONINDICATOR
OPTIONALCONDUIT ENTRY
.25 (6.35)
.35 (9)
.39 (9.9)
MANUALOVER RIDE
1.47 (37.3)
45°
OPEN
REMOVE DOME TO ACCESSMANUAL OVER RIDE
4, .207 DIA HOLES, .563 DP.1/4-20 TAP, .44 DP.2.121 B.C.
4, .149 DIA HOLES .563 DP.10-24 TAP, .44 DP.1.653 B.C.
4.13
5.752.39
45°
.433
R Series F04 Mounting Pad
SPECIFICATIONS:
Torque 100 Lb-In (11.30 Nm)
Cycle time 2.5 seconds/90° 115Vac
Duty Cycle 25% standard 115Vac
Motor Permanent split capacitor
115Vac/1ph/50-6Hz standard
With thermal over load protection
L. R. Current 0.55 amps 115Vac
0.38 amps 230Vac
2.9 amps 12Vdc
2.4 amps 24Vdc
Enclosure NEMA 7 not certified, Class I group C&D,
Class II group E, F & G Div. 1&2 Specifications
Output ISO 5211 F03
Position Ind. Visual indicator
Wired for light indication
Lubrication Permanent
Weight 8 Lbs
Installation Universal
Temp. Range -40°F. to 140°F.
Heater & thermostat required 0°F. & below
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
4, 1/4-20 TAP, .44 (11.2) DP.1.9685 (50)B.C.
4, 10-24 TAP, .44 DP.1.4173 (36) B.C.
1, 1/2-14 NPTCONDUIT ENTRY
ALLOW 2-1/2" (63.5) FOR COVER REMOVAL
POSITIONINDICATOR
OPTIONALCONDUIT ENTRY
.25 (6.4)
MANUALOVER RIDE
45°
OPEN
REMOVE DOME TO ACCESSMANUAL OVER RIDE
4.95 (125.7)
1.34 (34)
.89 (22.6)
6.06 (153.9)5.25 (133.4)
2.88 (73.2)
2.0 (50.8)
.433 (11)
6
6.88 (174.8)2.0 (50.8)
4.25 (108)
2.88 (73.2)
ALLOW 3" (76.2) FORCOVER REMOVAL
5.39 (136.9)
1.0 (25.4)
1/2 NPT CONDUITENTRY
.63 (16)
1.75 (45.45)
OPTIONAL CONDUITENTRY
.55 (14)
4, 1/4-20 TAP, 0.44 (11.2) DP.1.969 (50) BC
45°
4, 5/16-18 TAP, .5 (12.7) DP.2.756" (70) BC.
2.43 (61.8)
POSITIONINDICATOR
TO MANUALLY OVER RIDEREMOVE BEACON AND ROTATESHAFT WITH 3/8'' (9.53) WRENCH
OPEN
4, 10-24 TAP, .44 (11.2) DP.1.4173 (36) B.C.
.91 (23.1)
DIMENSIONS (mm)
SPECIFICATIONS:
Torque 200 Lb-In (22.6 Nm) & 300 Lb-In (33.9 Nm)
Cycle time 5 seconds/90° 115Vac & 230Vac
10 seconds/90° with 75% duty cycle
9.0 seconds/90° 12Vdc, 24Vdc & 24Vac
Duty Cycle 25% standard 115Vac & 230Vac
75% optional
75% 12Vdc, 24V dc & 24Vac
Motor Permanent split capacitor
115Vac/1ph/50-60Hz standard
With thermal over load protection
L. R. Current 200 Lb-In 0.75 (22.6 Nm) amps 115Vac
300 Lb-In 0.99 (33.9 Nm) amps 115Vac
0.38 amps 230Vac
4.2 amps 12Vdc
3.2 amps 24Vdc
Enclosure NEMA 4 standard
CSA certified (CSAfile #LR79567)
Coating Thermally bonded polyester powder
Fasteners Captive, 300 series stainless steel
Output ISO 5211 F05
300 series stainless steel
Mounting Pad ISO 5211 F03, F05 & F07
Over Ride Manual, not declutching
Declutching manual over ride optional
DC voltage must be declutching
Brake Friction, standard
Position Ind. Visual indicator
Wired for light indication
Weight 10 Lbs.
Lubrication Permanent
Installation Universal
Temp. Range -40°F. to 150°F.
Heater & thermostat required 0°F. & below
Switches SPDT snap action
16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
7
SPECIFICATIONS:
Torque 200 Lb-In (22.6 Nm) & 300 Lb-In (33.9 Nm)
Cycle time 5 seconds/90° 115Vac & 230Vac
10 seconds/90° with 75% duty cycle
9.0 seconds/90° 12Vdc, 24Vdc & 24Vac
Duty Cycle 25% standard 115Vac & 230Vac
75% optional
75% 12Vdc, 24Vdc & 24Vac
Motor Permanent split capacitor
115Vac/1ph/50-60Hz standard
With thermal over load protection
L. R. Current 200 Lb-In 0.75 (22.6 Nm) amps 115Vac
300 Lb-In 0.99 (33.9 Nm) amps 115Vac
0.38 amps 230Vac
4.2 amps 12Vdc, 3.2 amps 24Vdc
Enclosure NEMA 4 standard
Coating Thermally bonded polyester powder
Fasteners Captive, 300 series stainless steel
Output ISO 5211 F05
300 series stainless steel
Mounting Pad ISO 5211 F03, F05 & F07
Over Ride Not available
Brake Friction, standard
Position Ind. Visual indicator
Wired for light indication
Weight 14 Lbs.
Lubrication Permanent
Installation Universal
Temp. Range -40°F. to 150°F.
Heater & thermostat required 0°F. & below
Switches SPDT snap action
16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc
NOTE: 24Vac motors are 24Vdc motors rectified for use with
24Vac voltage.
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
45.0°
1/2-14 NPTCONDUIT ENTRY
4, 1/4-20 TAP .44 (11.2) DPON 1.968 BC
4, 5/16-18 TAP .5 (12.7) DP.ON 2.756 (70) BC
3.1 (78.7)
4.75 (120.7)
ALLOW 3" (76.2) FORCOVER REMOVAL
.55 (14)
4.75 (120.7)
7.34 (186.4)
6.88 (174.8)
.63 (16)
2.11 (53.6)
4, 10-24 TAP, .44 (11.2) DP.1.4173 B.C.
DIMENSIONS (mm)
8
2.31 (58.7)
4, 1/4-20 TAP .44 (11.2) DP.1.969 (50) B.C.
1/2 N.P.T.CONDUITENTRY
8.53 (216.7) 9.41 (239)
8.66 (220)
7.78 (197.6)
3.13 (79.5)
3.2 (81.3)
OPTIONAL MANUAL OVER RIDE ANDPOSITION INDICATOR
6.39 (162.3)
1.39 (35.3)
.5 (12.7)
2.48 (63)
.63 (16)
ALLOW 4" (101.6) FORCOVER REMOVAL
.55 (14)STAR
OPTION #1ROTATE
THROUGH GEARS
OPTION #2DECLUTCHING WITH
HAND WHEEL
.38 (9.65)
POSITIONINDICATOR
OPEN
OPTION #3DECLUTCHING WITH
PUSH KNOB
.5 (12.7)
1.28 (32.5)
DIMENSIONS (mm)
9
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
Brake Friction, standard
Position Ind. Visual indicator, Wired for light indication
Weight 16 Lbs.
Lubrication Permanent
Installation Universal
Temp. Range -40°F. to 150°F.
Heater & thermostat required 0°F. & below
Switches SPDT snap action
16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc
SPECIFICATIONS:
Torque 200 Lb-In (23Nm) & 300 Lb-In (34Nm)
Cycle time 5 seconds/90° 115Vac & 230Vac
10 seconds/90° with 75% duty cycle
9.0 seconds/90° 12Vdc, 24Vdc & 24Vac
Duty Cycle 25% standard 115Vac & 230Vac
75% optional, 75% 12Vdc, 24Vdc & 24Vac
Motor Permanent split capacitor 115Vac/1ph/50-
60Hz standard with thermal over load
protection
L. R. Current 200 Lb-In (22.6 Nm) 0.75 amps 115Vac
300 Lb-In (33.9 Nm) 0.99 amps 115Vac
0.38 amps 230Vac, 4.2 amps 12Vdc,
3.2 amps 24Vdc
Enclosure NEMA 7 standard, CSA and UL certified
Coating Thermally bonded polyester powder
Fasteners 300 series stainless steel
Output ISO 5211 F05, 300 series stainless steel
Mounting Pad ISO 5211 F03, F05 & F07
Over Ride Manual, not declutching
Declutching manual over ride optional
DC voltage must be declutching
.5 (12.7)
1.28 (32.5)
Output ISO 5211 F07
300 series stainless steel
Mounting Pad ISO 5211 F07
Over Ride Manual, declutching
Brake Friction, standard
Position Ind. Visual indicator
Wired for light indication
Weight 18 Lbs.
Lubrication Permanent
Installation Universal
Temp. Range -40°F. to 150°F.
Heater & thermostat required
0°F. & below
Switches SPDT snap action
16 amp ½ HP 125, 250Vac,
0.5amp 125Vdc
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
B
A
A
C
2.81 (71.4)
9.03 (229.4)
ALLOW 4'' (101.6) FORCOVER REMOVAL
1.76 (44.7)
.63 (16) 1/2" NPTCONDUIT ENTRY
4, 5/16-18 TAP .4 (10.2) DEEP2.756 (70) B.C.
MANUAL OVER RIDEPUSH AND ROTATE TO ENGAGE,PUSH A SECOND TIME TO DECLUTCH
VISUAL POSITIONINDICATOR
7.09 (180.1)
4, 3/8-16 TAP .56 (14.2) DEEP 4.015(102) B.C. MH ONLY
.67 (17)
OPEN
Model A B CML - MS 7.0 (177.8) 2.38 (60.5) 2.63 (66.8)MH 8.5 (215.9) 3.13 (79.5) 3.38 (85.9)DIMENSIONS IN INCHESDIMENSIONS (mm)
SPECIFICATIONS:
Torque 400 Lb-In (45.2 Nm) model MS
675 Lb-In (76.3 Nm) model MR
1000 Lb-In (113 Nm) model ML
1500 Lb-In (169 Nm) model MH
Cycle time MS 10 seconds/90° 115, 230Vac & 12Vdc
MS 20 seconds/90° 75% duty, 24Vdc & 24Vac
MR & ML 15 seconds/90° 115, 230Vac & 12Vdc
MR & ML 30 seconds/90° 75% duty, 24Vdc & 24Vac
MH 30 seconds/90° 115, 230Vac & 12Vdc
MH 70 seconds/90° 75% duty, 24Vdc & 24Vac
Duty Cycle 25% standard 115Vac & 230Vac
75% optional
75% 12Vdc, 24Vdc & 24Vac
Motor Permanent split capacitor
115Vac/1ph/50-60Hz standard
With thermal over load protection
L. R. Current 115Vac MS & MR= 0.75 amps
115Vac ML & MH= 0.99 amps
230Vac MS, MR, ML & MH=0.38 amps
12Vdc 4.2 amps
24Vdc 3.2 amps
Enclosure NEMA 4 standard, CSA and UL certified
Coating Thermally bonded polyester powder
Fasteners 300 series stainless steel
10
3.13 (80)
8.50 (216)
2.81 (71)
9.0 (229)
ALLOW 4'' (102) FOR COVER REMOVAL
1.76 (44.7)
.63 (16)
.667 (17)
1/2" NPTCONDUIT ENTRY
4, 5/16-18 TAP .4 (10) DP.2.756 (70) B.C.
MANUAL OVER RIDEPUSH AND ROTATE TO ENGAGE, PUSHA SECOND TIME TO DECLUTCH
VISUAL POSITIONINDICATOR
7.1 (180)
8.5 (216)
OPTIONAL ADDITIONAL 1/2"NPT CONDUIT ENTRY
3.38 (86)
4, 3/8-16 TAP .56 (14)DP. 4.015 (102) B.C.
OPEN
2.2 (56)R .25 (8)
DIMENSIONS (mm)
Enclosure NEMA 7 standard, CSA certified
Coating Thermally bonded polyester powder
Fasteners 300 series stainless steel
Output ISO 5211 F07
300 series stainless steel
Mounting Pad ISO 5211 F07
Over Ride Manual, declutching
Brake Friction, standard
Position Ind. Visual indicator
Wired for light indication
Weight 20 Lbs.
Lubrication Permanent
Installation Universal
Temp. Range -40°F. to 150°F.
Heater & thermostat required
0°F. & below
Switches SPDT snap action
16 amp ½ HP 125, 250Vac,
0.5amp 125Vdc
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
SPECIFICATIONS:
Torque 400 Lb-In (45.2 Nm) model MS
675 Lb-In (76.3 Nm) model MR
1000 Lb-In (113 Nm) model ML
1500 Lb-In (169 Nm) model MH
Cycle time MS 10 seconds/90° 115, 230Vac & 12Vdc
MS 20 seconds/90° 75% duty, 24Vdc & 24Vac
MR & ML 15 seconds/90° 115, 230Vac & 12Vdc
MR & ML 30 seconds/90° 75% duty, 24Vdc & 24Vac
MH 30 seconds/90° 115, 230Vac & 12Vdc
MH 70 seconds/90° 75% duty, 24Vdc & 24Vac
Duty Cycle 25% standard 115Vac & 230Vac
75% optional
75% 12Vdc, 24Vdc & 24Vac
Motor Permanent split capacitor
115Vac/1ph/50-60Hz standard
With thermal over load protection
L. R. Current 115Vac MS & MR= 0.75 amps
115Vac ML & MH= 0.99 amps
230Vac MS, MR, ML & MH=0.38 amps
12Vdc 4.2 amps
24Vdc 3.2 amps
11
4, 5/16 DRILL 13/16 (21) DP.3/8-16 TAP 5/8 (16) DP.4.015 (102) B.C.
4, 5/16 DRILL 13/16 (21) DP.5/16-18 TAP 5/8 (16) DP.2.756 (70) B.C.
10
3.75
10
1.12
1.19
.31
.875
2.5
MANUAL OVER RIDEHAND WHEEL
POSITIONINDICATOR
9.96
3/4-14 NPTCONDUIT ENTRY
DIA.
ACROSS FLATS
OPEN
ALLOW 6'' (152) TO REMOVE COVER
6.88 Ø 7HAND WHEEL
3.0
(22.23)
(28.5)
(76)
(254)
(95) (32.5)
(254)
(175)
(95)
(178)
(30)
(63.5)
(8)
(253)
45°
1.293.75
Mounting Pad Male double “D” shaft with 4.242 BC
Over Ride Manual, declutching
Brake Power Off, optional
Position Ind. Visual indicator
Wired for light indication
Weight 40 Lbs.
Lubrication Permanent
Installation Universal
Temp. Range -40°F. to 150°F.
Heater & thermostat required 0°F. & below
Switches SPDT snap action
16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
SPECIFICATIONS:
Torque LA…2000 Lb-In (226 Nm)
LX…3840 Lb-In (434 Nm)
Cycle time LA…12 seconds/90°
LX…14 seconds/90°
Duty Cycle Continuous
Motor Permanent split capacitor
115Vac/1ph/50-60Hz standard
With thermal over load protection
L. R. Current 115Vac LA= 1.50 amps (FL=0.98 amps)
115Vac LX= 2.90 amps
230Vac LA= .80 amps
230Vac LX=1.50 amp
12Vdc LA=4.93 amps
12Vdc LX=6.83 amps
Enclosure NEMA 4 standard, CSA certified
NEMA 7 optional, CSA certified
Coating Thermally bonded polyester powder
Fasteners 300 series stainless steel
Output ISO 5211 F07
300 series stainless steel
12
45
12.9(328)
Ø 7.3 (185)
3.8
4.63 (118)
2.2
.13 (3.3)
5.44 (138)
5.3 (135)
B
14.0 (356)
45°
13.5 (343)
13.5 (343)
16 (406)
C DIA.
ALLOW 7" FORCOVER REMOVAL
POSITIONINDICATOR
3/4-14 NPT CONDUITENTRY
OPTIONALCONDUIT ENTRY
DECLUTCHINGMANUAL OVER RIDE
4, 5/8-11 TAP, 3/4 (19) DP.,5.5118 (140) B.C.
4, 3/8-16 TAP, .63 (16) DP.,4.242 (107.7) B.C.
MODEL A B C 5K 1.19 .875 1.13 (30) (22.2) (28)
7K, 12K & 14K 1.60 1.42 2.38 (41.6) (36.1) (60.5)DEMINSIONS (mm)
A
OPEN
(96.5) (56)
Over Ride Manual, declutching
Brake Power Off, optional
Position Ind. Visual indicator
Wired for light indication
Weight +110 Lbs.
Lubrication Permanent
Installation Universal
Temp. Range -40°F. to 150°F.
Heater & thermostat required 0°F. & below
Switches SPDT snap action
16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
SPECIFICATIONS:
Torque Model 5K=5000 Lb-In (565 Nm)
Model 7K=7020 Lb-In (793 Nm)
Model 12K=11520 Lb-In (1302 Nm)
Model 14K=14040 Lb-In (1586 Nm)
Cycle time 68 seconds/90°
Duty Cycle Continuous
Motor Permanent split capacitor
115Vac/1ph/50-60Hz standard
With thermal over load protection
L. R. Current 115Vac 5K=2.9 amps, 7K=4.1 amps
12K & 14K=7.1 amps
230Vac 5K= 1.5 amps, 7K=2.3 am
12K & 14K=3.8 amps
12Vdc 5K=4.93 amps, 7K=6.83 amps
24Vdc 5K= amps, 7K= amps
Enclosure NEMA 4 standard
NEMA 7 optional
Coating Thermally bonded polyester powder
Fasteners 300 series stainless steel
Mounting Pad Male double “D” shaft 300 series stainless steel
13
MODEL 27K
12.88 (327.2)
3.75 (95.3)
4.62 (117.3)
2.19 (55.6)
13.52 (343.4)
13.5 (342.9)
16 (406.4)
ALLOW 7" (177.8) FORCOVER REMOVAL
3/4-14 NPT CONDUITENTRY
OPTIONAL CONDUITENTRY
DECLUTCHINGMANUAL OVER RIDE
8.0 (203.2)
CLOSE
OPEN
6.06 (153.9)
27.15 (689.6)
8.06 (204.7)
5.15 (130.8)5.31 (134.9)
18.81 (477.8)
CLOSE
OPEN
.625 (15.9)
Ø 7.50 (190.5)
1.457 (37.01)
8, 5/8-11 TAPPED HOLES, 1(25.4) DP.
BOTTOM VIEWMOUNTING DIMENSIONS
22.5°
45°
2.375 +.005/-.000
(60.33) BORE
KEYWAY
Mounting Pad 2.375’’ Bore
Over Ride Manual, declutching
Brake Power Off, optional
Position Ind. Visual indicator
Wired for light indication
Weight 170 Lbs.
Lubrication Permanent
Installation Universal
Temp. Range -40°F. to 150°F.
Heater & thermostat required 0°F. & below
Switches SPDT snap action
16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
SPECIFICATIONS:
Torque 27300 Lb-In (3084 Nm)
Cycle time 136 seconds/90°
Duty Cycle Continuous
Motor Permanent split capacitor
115Vac/1ph/50-60Hz standard
With thermal over load protection
L. R. Current 115vAC = 7.1 amps
230vAC = 3.8 amps
Enclosure NEMA 4 standard
NEMA 7 optional
Coating Thermally bonded polyester powder
Fasteners 300 series stainless steel
14
3.13 (80)
8.5 (216)
2.81 (71)
ALLOW 4'' (101.6)FOR COVER REMOVAL
1.76 (44.7)
.63 (16)
.667 (17) 1/2" NPTCONDUIT ENTRY
4, 5/16-18 TAP .4 DP.2.756 (70) B.C.
VISUAL POSITION INDICATOR
7.1 (180)
8.5 (216)
OPTIONAL ADDITIONAL1/2" NPT CONDUIT ENTRY
3.38 (86)
4, 3/8-16 TAP .56 DP. 4.015 (102) B.C.
OPEN
MECHANICAL STOPFAIL CLOSE
DIMENSIONS (mm)
ICI’s model ES2 electric spring return actuator is a
light duty actuator designed for fail-safe
applications. It is recommended for applications
requiring system protection from unforeseen power
failures. This actuator is not recommended for
applications requiring several open/close cycles per
day.
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
OPTIONAL ADDITIONAL
1/2 NPT CONDUIT ENTRY
1/2 NPT
CONDUIT ENTRY
VISUAL POSITION INDICATOR
MECHANICAL STOP
FAIL CLOSED
ALLOW 4’’ FOR COVER REMOVAL
4, 3/8-16 TAP .56 DP.
4.015 B.C.
4, 5/16-18 TAP .40 DP.
2.756 B.C.
SPECIFICATIONS:
Torque 200 Lb-In (22.6 Nm)
Cycle time 10 seconds/90° 115 or 230Vac
Duty Cycle 5% standard 115Vac or 230Vac
Motor Permanent split capacitor
115Vac/1ph/50-60Hz standard
With thermal over load protection
L. R. Current 115Vac = 0.75 amps
230Vac = 0.38 amps
Enclosure NEMA 4 standard
NEMA 7 optional
Coating Thermally bonded polyester powder
Fasteners 300 series stainless steel
Output ISO 5211 F07
300 series stainless steel
Mounting Pad ISO 5211 F07
Brake Power on, standard
Position Ind. Visual indicator
Weight 24 Lbs.
Lubrication Permanent
Installation Universal
Temp. Range -40°F. to 150°F.
Heater & thermostat required 0°F. & below
Switches SPDT snap action
16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc
15
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
3/4-14 NPTCONDUIT ENTRY
10.0 (254)
CF
3.75 (95)
D
E3.75 (95)
B
A
SPRING END TORQUEADJUSTING SCREW,SET AT FACTORY
SPRING END POSITIONADJUSTING SCREW,SET AT FACTORY
3.0 (76)
DIMENSIONS IN INCHES
MODEL A B C D E F G H
AS4 & 6 14.69 4.69 .75 15.66 5.06 2.0 .660 5.0 (373) (119) (19) (397.8) (128.5) (50.8) (16.76) (127)
AS10 15.06 4.88 1.0 17.0 5.88 2.5 1.0 6.0 (382.5) (124) (25.4) (431.8) (149.4) (63.5) (25.4) (152.4) (mm)
ALLOW 6" FORCOVER REMOVAL
CATALOG DRAWING FOR SPRING RETURNACTUATOR
ICIIndelac Controls, Inc. Florence, Ky. 41042
CD0605265-26-2006JLR
1" = 1"
AS4 & 6....4, 5/16-18 X 5/8" DP., 2.756 (70) B.C.AS10.........4, 1/2-13 X 5/8" DP., 4.010 (102) B.C.
2.0 (50.8)
G
6.25 (158.8)
SQUARE
H
10.0 (254)
45.0°
SPECIFICATIONS:
Torque AS4 400 Lb-In (45.2 Nm)
AS6 600 Lb-In (67.8 Nm)
AS10 1000 Lb-In (113 Nm)
Cycle time 12 seconds/90° 115 or 230Vac
Duty Cycle 25% standard 115Vac or 230Vac
Motor Permanent split capacitor
115Vac/1ph/50-60Hz standard
With thermal over load protection
L. R. Current 115Vac = 2.91 amps
230Vac = 2.40 amps
Enclosure NEMA 4 standard
NEMA 7 optional
Coating Thermally bonded polyester powder
Fasteners 300 series stainless steel
Output AS4 & AS6 ISO 5211 F07 = 0.66 Male
AS10 = 1.0” Male
Mounting Pad ISO 5211 F07
Brake Power on, standard
Weight AS4 & AS6 = 68 Lbs.
AS10 = 78 Lbs.
Lubrication Permanent
Installation Universal
Temp. Range -40°F. to 150°F.
Heater & thermostat required 0°F. & below
Switches SPDT snap action
16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc
ICI’s models AS4, AS6 & AS10 electric spring
return actuators are heavy duty actuators
designed for fail-safe applications. They are
recommended for applications requiring
system protection from unforeseen power
failures. These actuators are recommended for
applications requiring approximately 25
open/close cycles per day.
16
1.13 (28.7)
.998 (25.35)
8.66 (220)
7.78 (197.6)
3.2 (81.28)
3.13 (79.5)
5.5 (127)
2.5 (63.5)
1.0 (25.4)STROKE
4.0 (101.6)
1.13 (28.7)
.998 (25.35)1.0 (25.4)STROKE
4.0 (101.6)
21.0 (533.4)
16.5 (419.1)
ALLOW 4" (101.6) FORCOVER REMOVAL
4, 1/4-20 TAP .44 (11.2) DP.2.756 (70) B.C.
45.0°
1/2 N.P.T.CONDUITENTRY TYP.
TWO POSITION SERIES12 LINEAR ACTUATOR1'' STROKE SHOWN
TWO POSITION SPRING RETURNSERIES 12 LINEAR ACTUATOR 1''STROKE SHOWN
1/2-20 TAP3/4 DP.
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
SPECIFICATIONS:
Thrust 280 Lb
Cycle time 3 IPM
Duty Cycle 75% standard 115Vac
Motor Permanent split capacitor
115Vac/1ph/50-60Hz standard
With thermal over load protection
L. R. Current 0.58 amps 115Vac
Enclosure NEMA 4 standard
Coating Thermally bonded polyester powder
Fasteners Captive, 300 series stainless steel
Output ISO 5211 F05
300 series stainless steel
Mounting Pad ISO 5211 F05
Brake Friction, standard
Power Off (optional)
Position Ind. Wired for light indication
Weight 16 Lbs. (as shown)
Lubrication Permanent
Installation Universal
Temp. Range -40°F. to 140°F.
Heater & thermostat required 0°F. & below
Limit Switches SPDT snap action (optional on 4-20mA control)
16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc
Feedback Pot. Linear (optional)
Positioner Analog 4-20mA (optional)
17
Ø 1.3
9.58
3.33
2, 1/2-14 NPT CONDUITENTRIES
1.25
ACROSS FLATS(9.4mm)
1 3/4-12 UN-2ATHREAD
STROKE(25.4mm)
1/4-20 UNC-2A
ICI's linear CV series Control Valve actuators are equippedwith high resolution control boards, two 1/2'' NPT conduitentries, soft stop and end of position limit switches.
2.87
2.66
5.32
.32
OPTIONAL MANUAL OVER RIDECRANK HELD IN PLACE BY CLIP
MANUAL OVER RIDEACCESS NUT
.75.37
1.0
SOFT STOP FEATURE TOPROTECT VALVE SEAT
.49
7.68
(8.13mm)
( 243.3mm)
(195.1mm)
(31.8mm)
(19.1mm)
(8.5mm)
(33mm)
(12.5mm)
(67.6mm)
(135.1mm)
(mm) Dimensions in milimeters
(72.9mm)
SPECIFICATIONS:
Thrust 165 Lb
Cycle time 9.6 IPM
Duty Cycle 75% duty cycle
Motor Permanent split capacitor
115Vac/1ph/50-60Hz standard
With thermal over load protection
12 & 24Vdc available
L. R. Current 0.58 amps 115Vac
Enclosure NEMA type 4, 4X, 9 & 7 for Class I,
Groups C & D, Class II, Groups E, F
& G, Division 1 & 2
Hazardous Location.
Coating Thermally bonded polyester powder
Fasteners Captive, 300 series stainless steel
Output Drive 300 series stainless steel
Position Ind. 4-20mA optional
Weight 20 Lbs.
Lubrication Permanent
Installation Universal
Temp. Range -40°F. to 140°F.
Heater & thermostat required 0°F. & below
Limit Switches SPDT snap action (optional on 4-20mA control)
16 amp ½ HP 125, 250Vac, 0.5amp 125Vdc
Feedback Pot. Linear
Positioner Analog 4-20mA
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
18
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
19
(0° to 46° C).
The above distances should be considered as maximums
Fail-Safe
Watts Actuator Series
Wire Gage Size
12 10 8 6 4
100
R 25ft 50ft 60ft 75ft 100ft
S, SD, MS & MR 20ft 40ft 50ft 65ft 85ft
SX & SDX 15ft 35ft 45ft 60ft 75ft
150 ML & MH 15ft 35ft 45ft 60ft 75ft
500 LA - - 20ft 35ft 50ft
LX & 5K - - 15ft 30ft 45ft
700 7K - - 10ft 25ft 40ft
1000 12K & 14K - - 10ft 25ft 40ft
20
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
Indelac’s control panels are designed to provide
dependable operation as well as meet NEMA 4
specifications. While ICI offers a number of standard
control panels we also design special controls for
various applications. If your needs do not fall within
the realm of our standard control panels please call or
email your specifications for design consideration.
21
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
22
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
23
Quarter
Turn
Actuator
Torque
(In/Lbs)
Torque
(Nm)
Cycle Time
(Sec./90 Deg.)
Lock Rotor
Current in
Amps for
115Vac
R 100 11.3 2.5 0.55
SD 200 22.6 5 0.75
SDX 300 33.9 5 0.75
SR 200 22.6 5 0.75
SX 300 33.9 5 0.75
MS 400 45.2 10 0.75
MR 675 76.3 15 0.75
ML 1000 113 15 0.75
MH 1500 170 30 0.75
LA 2000 226 12 1.5
LX 3840 434 14 2.9
5K 5000 565 68 2.9
7K 7020 793 68 7.1
12K 11520 1299.3 68 7.1
14K 14040 1586.3 68 7.1
27K 27300 3084.5 136 7.1
Spring
Return
Actuator
Torque
(In/Lbs)
Torque
(Nm)
Cycle Time
Power/Spring
Lock Rotor
Current in
Amps for
115Vac
ES2 200 22.6 10/2 0.75
AS4 400 45.2 12/3 1.5
AS6 600 67.8 12/4 1.5
AS10 1000 113 12/5 2.9
Steps To Create Model Number
1. Choose Actuator Series by Torque:
2. Enclosure
NEMA 4 = 4, NEMA 4X = 4X, NEMA 7 =
7, NEMA 4 & 7 = 4/7 (S, M, L, ES & AS)
3. Voltage
A=24Vac, B=115Vac, Z=115Vac Ext. duty
doubles cycle time, pertains to S & M series,
C=230Vac/1Ph, D=12Vdc, E=24Vdc,
G2=230V-3Ph, G3=380V-3Ph-50Hz,
G4=440-3PH, J=208Vac
Voltage symbol followed by an M designates
Metric tapped mounting holes.
4. Mounting Pad
R series=F03, F04 or F03/04, SR/SX=F05,
M series=F07 all others NA.
5. Cycle Time (See list)
* Fail Designation (Spring Return Only)
FC = Fail Close, FO = Fail Open.
OPTIONS: 6. Auxiliary Switch -S=1, -2S=2, -3S=3, -4S=4.
7. Manual over ride Standard on all NEMA 4 enclosures no symbol
required. Standard on K, L & M series NEMA 7
enclosure. M symbol required on M series only. S
series over ride with hand wheel. . M=Manual over ride
with push knob. Consult factory for availability on
spring return actuators.
8. Brake P=Power On Brake, P1=115V, P2=230V, P3=24Vac,
P4=12Vdc, P5=24Vdc Power Off Brake.
9. Potentiometer -1=Signal turn 1K, -1A= Dual signal turn 1K, -1B=Pot
with 3:1 ratio, -5K=Signal turn 5K.
10. Positioner VP=Modulating control 4-20mA, 0-10Vdc all voltages,
VQ=High resolution
NOTE: Actuators with output torque below
1500 lb-in are equipped with 25% duty cycle
motors, when used for modulating service
extended duty motors are supplied which
doubles the cycle time.
24
11. Heater or Heater & Thermostat H=heater normally used for condensation, HT=heater &
thermostat used for temperature control
12. Breather BR normally used for condensation.
13. Speed Control SC used to increase standard cycle time.
14. Timer T allows repeat of open to close cycle at same time
every day.
15. Three Position -3P used for three positions control, i.e., 0, 90 & 180
deg., also for dribble control.
16. Light indication L green light to indicate open position & red light to
indicate close position.
17. Visual Indicator DI=Beacon, D=Pointer, Dome style indicator standard
on all actuators except SR, SX & AS series.
18. Transmitter -TX=4-20mA position transmitter.
19. Remote/Off/Local RL=Remote/off/local control panel with selector
switches and light indication.
20. Two Wire Control TW= Open/close control using relay (230Vac, 120Vac,
24Vac, 24Vdc or 12Vdc available).
21. Torque Sensor -TS electronic torque sensor (current sensor).
22. Multi-Turn -MT multiple revolutions.
23. Reversing Contact RC reversing control for DC & 3Ph. motors.
24. Transformer -TR control voltage transformer used on 3 Ph. motors.
25. Additional Conduit AC one additional conduit entry, not available on all
models.
26. Special Mounting PC special mounting pad configuration.
27. Mechanical Stop MS mechanical stop.
EXAMPLE: Electric actuator to deliver 1000 LB-IN torque, 120Vac, NEMA 7 enclosure, 2
auxiliary switches, heater & thermostat.
In the chart, find 1000 LB-IN torque, select model ML, straight across to the right find the cycle
time, 15sec/90 deg. Start down the selection list and pick out the items required for your
application and list them in the order they fall in, if an item is not selected merely ignore it. The
model number for our example would be: ML7B-15-2SHT
25
R SD S M L K ES2 AS R SD S M L K ES2 AS
Enclosure NEMA Type 4X Speed Control 12Vdc
Type 4 NEMA Type 6 24Vdc
Standard NEMA Type 7 24Vac
NEMA Type 4 & 7 115Vac
Motor 115Vac Ext 'ed Duty 230Vac
Voltage 24Vac
115Vac 24Vdc T imer 12Vdc
Standard 12Vdc 24Vdc
208Vac/1ph/60Hz 24Vac
230Vac/1Ph/60Hz 115Vac
230Vac/3Ph 230Vac
380Vac3Ph/50Hz Multi-Position, Three Position
460Vac/3Ph Vac Four Position
Coating Epoxy Coating Multi-Position, Three Position
Anodize Vdc Four Position
Auxiliary One Position Diamond
Switches Two Indicator ICI Dome
Three Light Indication
Four 4-20mA Transmitter
Proximity Limit Three Position 3 3 3 3 3
Switches Two Auxiliary Power Supply 115Vac or 230Vac
Declutching NEME Type 4 1 1 1 Two Conduit NEMA Type 4
Man-O-Ride NEME Type 7 Entries NEMA Type 7
Brake, 12Vdc Mechanical Stop
Power On 24Vdc Breather
24Vac Heater
115Vac 1 1 Heater & Stat.
230Vac 1 1 Torque Sensor
Brake, 12Vdc Multi-Turn
Power Off 24Vdc Reversing DC Voltage
24Vac Contactor 3 Ph. Motors
115Vac T ransformer
230Vac 2 Wire Control 12Vdc
Potentiometer 1K, Single Turn 24Vdc
1K, Single Turn, Dual 24Vac
1K, 3:1 Ratio 115Vac
1K, 0 to 135 ohm 230Vac
1K, Ten Turn Remote Local
5K, Single Turn Control
Positioner 12Vdc & 24Vdc 2
24Vac 1. Standard equipment
115Vac 2 2. Assembled in SD enclosure
230Vac 2 3. Third party vendor
115Vac High Resolution
0-135 ohm
SERIES SERIES
OPTIONS OPTION
26
27
28
1 2 3 4 5 6 7 8 9 10
N HOT
A.C.SUPPLYPOWER
PSC MOTOR
CAPACITOR
SW. #2
WIRING DIAGRAN FOR STANDARD1PH/60Hz/AC ELECTRIC ACTUATORILLUSTRATING SOME COMMON OPTIONS
JLR 5-19-99
990520
ICI Indelac Controls, Inc.
OPTIONALBRAKE
SW. #1 CLOSE LIMIT
SW. #2 OPEN LIMIT
SWITCH LAYOUT
OPTIONAL HEATER& THERMOSTAT
NO
NC
L
L
1 2 3 4 5 6 7 8 9 10
N HOT
A.C.SUPPLYPOWER DPDT CONTROL SWITCH
SHOWN FOR ILLUSTRATIONONLY
FIELD WIRING
PSC MOTOR
CAPACITOR SW. #1
JLR 5-19-99
990520
ICI
NOTES:POWER TO TERMINALS ONE & TWO OPENS THE VALVE(CCW ROTATION)POWER TO TERMINALS ONE & THREE CLOSES THE VALVE(CW ROTATION)TERMINALS 4 & 5 ARE FOR LIGHT INDICATION
WIRING DIAGRAM ILLUSTRATES THE ACTUATOR IN THEOPEN POSITION
GROUNDSCREW
OPTIONALBRAKE
SW. #1 CLOSE LIMIT
SW. #2 OPEN LIMIT
SWITCH LAYOUT
OPTIONAL HEATER& THERMOSTAT
C
NCNO
C
NO
L
L
LIGHTS FOR REMOTEPOSITION INDICATION
OPTIONAL EQUIPMENTFIELD WIRING
Two Position Actuator
1 2 3 4 5 6 7 8 9 10
N HOT
A.C.SUPPLYPOWER
DPDT CONTROL SWITCHSHOWN FOR ILLUSTRATIONONLY
FIELD WIRING
PSC MOTOR
CAPACITOR
SW. #2
SW. #1
WIRING DIAGRAN FOR TWO POSITION 1PH.ELECTRIC ACTUATOR ILLUSTRATINGSEVERAL COMMON OPTIONS
JLR 4-5-99
990405
ICI Indelac Controls, Inc.
NOTES:POWER TO TERMINALS ONE & TWO OPENSTHE VALVE (CCW ROTATION)POWER TO TERMINALS ONE & THREE CLOSESTHE VALVE (CW ROTATION)TERMINALS 4 THROUGH 9 FOR AUXILIARYSWITCHCONNECTIONS
WIRING DIAGRAM ILLUSTRATES THEACTUATOR IN THE OPEN POSITION
GROUNDSCREW
OPTIONALBRAKE
C NO NC C NO NC
OPTIONAL AUXILIARY SWITCHES
SW. #3 SW. #4
SW. #1 CLOSE LIMIT
SW. #2 OPEN LIMIT
SW. #3 CLOSE AUXILIARY
SW. #4 OPEN AUXILIARY
SWITCH LAYOUT
OPTIONAL HEATER &THERMOSTAT
WHT
BLK
BLK
RED
BLU
BLK
BLK
WHT
BLK
BLK
BLK
BLK
BLK BLK
BLKWHT
NO NC
C
NO NC
C
SWITCHNO.
CONTACTSWIRED
OPEN CLOSE
NO
NC
NO
NC
NO
NC
1
2
3
4NC
NO
MID
AUXILIARY SWITCHES (SW#3 & #4) MAY BE SET TO ANYDESIRED POSITION THROUGH OUT ACTUATOR TRAVEL
OPT.
OPT.
OPTIONAL EQUIPMENT
FIELD WIRING
Two Position Actuator with Brake, Two Auxiliary Switches, Heater & Thermostat
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
29
1
5 8
4
129
13 14
CAMCAM
RELAY
1 2 3 4 5 6
DC MOTOR
SW.#1 SW.#2
POSITIVE NEGATIVE
ACTUATOR SHOWN IN THE OPENPOSITION
DC POWERSUPPLY
OPERATION:
SUPPLY POWER IS ALWAYS ON.
CONNECTION:SUPPLY POWER TO T1 & T2CONTROL VOLTAGE TO T3 & T4T5 & T6 SUPPLIED FOR LIGHT INDICATION.
ACTUATOR
FIELDWIRING
CONTROL SWITCH, FORILLUSTRATION ONLY
HEATER &THERMOSTATOPTIONAL
11-20-98 W981120
ICIIndelac Controls, Inc. Hebron, KY 41048
WIRING DIAGRAM FOR TWO POSITION DCACTUATOR WITH TWO WIRE CONTROL
JLR
OPTIONAL EQUIPMENTFIELD WIRING
15 8 4
129
13 14
CAM
CAM
RELAY
1 2 3 4
SW.#1
SW.#2
NEU. HOT
ACTUATOR SHOWN IN THE OPEN POSITION
1PH/60HZ AC POWERSUPPLY
ACTUATOR IS SHOWN IN THE OPEN POSITION
OPERATION:SUPPLY POWER IS ALWAYS ON.CONTROL IS THROUGH THE VENDOR SUPPLIED CONTROLDEVICE. (SHOWN HERE AS A SPST SWITCH)ACTUATOR SHOWN IN DIAGRAM IS WIRED FORNORMALLY CLOSE OPERATION. ACTUATOR OPENS WITHCONTACT CLOSURE OF CONTROL DEVICE. ACTUATORCLOSES WHEN CONTROL CONTACT IS OPENED.
CONNECTION:SUPPLY POWER TO T1 & T2CONTROL VOLTAGE TO T3 & T4TERMINALS T5 AND T6 FOR LIGHT INDICATION
ACTUATOR
FIELDWIRING
SPST CONTROL SWITCHFOR ILLUSTRATION ONLY
OPTIONALBRAKE
SW#1
SW#2
CLOSE SWITCH
OPEN SWITCH
HEATER &THERMOSTATOPTIONAL
5 6
GREENGROUNDSCREW
7-23-90 W900723
ICIIndelac Controls, Inc. Florence, KY 41042
WIRING DIAGRAM FOR TWO POSITION ACACTUATOR WITH TWO WIRE CONTROL
JLR
OPTIONAL EQUIPMENTFIELD WIRING
AC Actuator with 2 Wire Control
DC Actuator with 2 Wire Control
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
30
1 2 3 4 5 6 7 8 9 10
SW#1 SW#2 SW#3 SW#4
SW.#4 CW
SW.#3 CCW
SW.#2 CW
SW.#1 CCW
60HZ/1PH/VACCONTROL SWITCHFOR ILLUSTRATIONONLY
NEU. HOT
OPERATION:POWER TO TERMINAL #1 & #2 POSITIONS SHAFT TO ZERO DEGREE "CCW ROTATION"POWER TO TERMINAL #1 & #3 POSITIONS SHAFT TO 180 DEGREE POSITION "CW ROTATION"POWER TO TERMINAL #1 & #4 POSITIONS SHAFT TO 90 DEGREE POSITION "CCW ROTATION"POWER TO TERMINAL #1 & #5 POSITIONS SHAFT TO 90 DEGREE POSITION "CW ROTATION"
TERMINALS 7, 8, 9 & 10 ARE FOR LIGHT INDICATION WHEN A LAMP IS CONNECTEDBETWEEN CONNECTION AND NEUTRAL.
DO NOT APPLY POWER TO TERMINAL #1 & #3 WITH ACTUATOR IN PODITION 'D', ACTUATORWILL OVER TRAVEL
FIELD WIRING
FIELDWIRING
12-18-96 W891101
SWITCH LAYOUT
PSC MOTOR
A
B C
D
BRN RED
CAPACITOR
BLK
BLK
BLK
BLK
NO
NC
C C C C
NO
NCNC
NO
NC
NO
WHT
BLU
RED
BLU
RED
YEL
ORG YEL
ORG
ICI Indelac Controls, Inc.
WIRING DIAGRAM FOR THREE POSITION 1PHELECTRIC ACTUATOR WITH SOME COMMON OPTIONS
JLR
115Vac Three Position Actuator
DCMOTOR
1 2 3 4 5 6 7 8 9 10
SW#2CW
SW#4CCW
SW#3CW
SW.#4
SW.#3
SW.#2
SW.#1
DC Voltage
CONTROLSWITCH
+ -
OPERATION:POWER TO TERMINAL #1 & #2 POSITIONS SHAFT TO ZERO DEGREE "CCW ROTATION"POWER TO TERMINAL #1 & #3 POSITIONS SHAFT TO 90 DEGREE POSITION "CW ROTATION"POWER TO TERMINAL #1 & #4 POSITIONS SHAFT TO 180 DEGREE POSITION "CW ROTATION"POWER TO TERMINAL #1 & #5 POSITIONS SHAFT TO 90 DEGREE POSITION "CCW ROTATION"
TERMINALS 7, 8, 9 & 10 ARE FOR LIGHT INDICATION WHEN A LAMP IS CONNECTED BETWEENCONNECTION AND NEUTRAL.
FIELD WIRING
FIELDWIRING
ICI Indelac Controls, Inc.
WIRING DIAGRAM FOR 12 & 24VDCTHREE POSITION ELECTRIC ACTUATOR
1-2-06 W060201
C C C
NO NO NO NONC NC NC NC
C
SW#1CCW
51 84
129
13 14
51
9
13 14
84
12
RED
BLK
ZERO DEGREES
180 DEGREES
90 DEGREES CW ROTATION
90 DEGREES CCW ROTATION
RED
RED
NOTE:RELAY CONNECTIONSNC = #1 & #4NO = #5 & #8 C = #9 & #12COIL = #13 & #14
51 84
129
13 14
RED
BLU
BLK
RED
YEL
BLK
ORG
YEL
RED
BLU
BLK
BLK
ORG
RED
BLK
BLK
BLK
RED BLK
51 84
129
13 14
RED
RED
RED
RED
BLK
BLK
RED
RED
BLK
BLK
0 90 180 90
JLR
Three Position DC Actuator
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
31
1 2 3 4 5 6 7 8 9 1011 12
3 PHASE MOTOR
SW. #1 SW. #2 SW. #3 SW. #4
CAM CAM CAM CAM
SW. #1
SW. #2
SW. #3
SW. #4
CLOSE LIMIT SWITCH
OPEN LIMIT SWITCH
CLOSE POSITION AUXILIARY SWITCH
OPEN POSITION AUXILIARY SWITCH
L1 L2 L3
3 PHASE POWERSUPPLY
A. CONTROL VOLTAGE TRANSFORMERB. REVERSING CONTACTORC. HEATER & THERMOSTAT (OPTIONAL)
OPTIONAL EQUIPMENTFIELD WIRING
C NO
NC
C NO
NC
AUXILIARY SWITCHCONNECTIONS
ICIIndelac Controls, Inc. Florence, Ky. 41042
JLR 3-6-00
WIRING DIAGRAM FOR 3PH. ACTUATOR WITHREVERSING CONTACTOR, CONTROL VOLTAGETRANSFORMER & TWO AUXILIARY SWITCHES
SWITCH LAYOUT
BLU
BLK.
BLK.
WHT
FIELDWIRING
AUXILIARY SWITCHES
3 6 9
471
2 5 8
H1
H2
H3
H4
X2
X1
A
B
C
OPEN
CLOSE
OPTIONAL
W000306
RED
BLK
3 Phase with Reversing Contactor And Control Voltage Transformer
1 2 3 4
N HOT
A.C.SUPPLYPOWER
DPDT CONTROL SWITCHSHOWN FOR ILLUSTRATIONONLY
FIELD WIRING
PSC MOTOR
CAPACITOR
SW. #2
SW. #1
WIRING DIAGRAN FOR SPRING RETURNELECTRIC ACTUATOR WITH TWOAUXILIARY SWITCHES.
JLR 9-10-99
990910
I CI
Indelac Controls, Inc. Hebron, Ky. 41048
NOTES:POWER TO TERMINALS ONE & TWO OPENS THE VALVE(CCW ROTATION)POWER TO TERMINALS ONE & THREE CLOSES THE VALVE(CW ROTATION)TERMINAL 4 SUPPLIES 120V HOT TO BRAKE.TERMINALS 5 THROUGH 10 FOR AUXILIARY SWITCHCONNECTIONS
WIRING DIAGRAM ILLUSTRATES THE ACTUATOR IN THEOPEN POSITION
THIS IS A FAIL-SAFE ACTUATOR DO NOT USE INCONTROL TYPE APPLICATIONS
GROUNDSCREWBRAKE
OPTIONAL AUXILIARY SWITCHESSW. #1 CLOSE LIMIT
SW. #2 OPEN LIMIT
SW. #3 CLOSE AUXILIARY
SW. #4 OPEN AUXILIARY
SWITCH LAYOUT
NO
C
NC
NC
C
NO
HEATER &THERMOSTAT,OPTIONAL
REDBRN
BLK
4 5 6 7 8 9
C NO NC C NO NC
SW. #3 SW. #4
BLK
BLK
BLK
BLK
BLK BLK
OPTIONAL
FIELD WIRING
YEL
ORG
BLU
RED
Spring Return Actuators
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
32
8 7 6 5 4 3 2 1 6 5 4 3 2 1 J1J2
4-20mA POSITIONER
PSC MOTORCAPACITOR
SW. 1, CLOSE
SW. 2, OPEN
SW.2
SW.1
BRAKEOPTIONAL
1PH-60HZPOWER SUPPLY
4-20mA CONTROLSIGNAL
0-10VDC or 0-5VDCCONTROL SIGNALREMOVE JP2, JP3 & JP4
1K OHM FEEDBACKPOTENTIOMETER
BLU
RED
WHT
BLK
BLK
BLK
WHT
FIELDWIRING
NHOT
-
+
+
ICI
Indelac Controls, Inc. W000203
JLR 2-3-00
NOTE:ACTUATOR SHIPPED IN OPENPOSITION, 20mA REPRESENTS OPENPOSITION. DO NOT ADJUST FEEDBACKPOTENTIOMETER OR LIMIT SWITCHESTHEY ARE FACTORY SET AND DO NOTREQUIRE CALIBRATION. TOCALIBRATE THE OPEN AND CLOSEPOSITION USE THE ZERO (4mA) ANDSPAN (20mA) TRIM POTENTIOMETERS.
TO CALIBRATE OPERATE ACTUATORTO CLOSE POSITION AND ADJUST WITHZERO TRIM POT THEN OPERAT TOOPEN POSITION AND SET USING SPANTRIM POT. NO FUTHER CALIBRATION ISNECESSARY.
HEATER &THERMOSTATOPTIONAL
WIRING DIAGRAM FOR 1Ph/60Hz ELECTRICACTUATOR WITH 4-20mA, 0-5Vdc OR 0-10Vdc CONTROL.
JP2
RED
GREEN
JP3
JP4
FUSE
DEADBAND
JP1
ZERO
SPANC
NO NC
C
NONC
JP2
RED
GREEN
JP3
JP4JP2
RED
GREEN
JP3
JP4 JUMPER SET FORFAIL OPEN UPONLOSS OF CONTROLSIGNAL
JUMPER SET FORFAIL CLOSE UPONLOSS OF CONTROLSIGNAL
JUMPER AS SHOWN BELOW IS FAIL INLAST POSITION UPON LOSS OF SIGNAL
GRN
RED
C
NO NC
C
NONC
9 10 11 12 13 14
SW. 3, CLOSE
SW. 4, OPEN
AUXILIARY SWITCHESOPTIONAL
SW.4SW.3
OPTIONAL EQUIPMENTFIELD WIRING
115V Modulating Actuator
1 2 3 4 5 6 7 8 910
BRUSH TYPEDC MOTOR+ -
4-20mA POSITIONER
+ _10 TO 30 VDCPOWER SUPPLY
+5V OUTPUT
0 to 5V OR 0 to 10V
4 to 20mA CONTROL SIGNAL
J1J2
POSITIONER SPECIFICATIONS:POWER REQUIREMENTS:Operating voltage....10 to 30 VDCOperating Current (motor on)....87mA typicalOperating Current (trip output on)....40mA typicalStandby Current (motor off, trip off)....20mA typicalFuse Type....8A, BUSSMANN ABC-8COMMAND SIGNAL INPUT:Common Mode Voltage (all inputs)....-13 to +30VDC0-5VDC....Input Impedance = 10K ohms, External Command Pot. = 1K ohm0-10VDC....Input Impedance = 20K ohms1-5VDC....Input Impedance = 200K ohms, Loss of signal threshold </=0.75V4-20mA....Input Impedance= 250 OHMS +/-1%, Loss of command signalthreshold </= 3mAFEEDBACK SIGNAL INPUT:Input Voltage....0 to 5VDC, External feedback pot. 1K to 10K ohmsDC MOTOR OUTPUTS:Maximum load current = 15A Locked rotor for 20 seconds typical.ENVIRONMENTAL:Operating Temp. = -40 to 65 deg. C, Storage Temp. = -40 to 85 deg. C.Relative Humidity Range = 0 to 90% (noncondensing)
ACTUATOR SHIPPED IN OPEN POSITIONUNLESS OTHERWISE SPECIFIED
WIRING DIAGRAM FOR DC ELECTRICACTUATOR WITH 4-20mA CONTROL
1-9-97
OPTIONAL HEATER (25Watt @ 68 Ohm) &THERMOSTAT (Required for applications below
0 deg. F.)
ZERO SPAN
THERMALOVER-LOADPROTECTION
1 2 3 4 5 6 7 8
JP5
JP1
JP2
JP3JP4
DEADBAND
FUSE
+
-
NOTE:LIMIT SWITCHES AND FEEDBACK POTENTIOMETER ARE SETAT THE FACTORY, CALIBRATIONS ARE NORMALLY NOTREQUIRED. TO CALIBRATE THE VALVE POSITION USE THEZERO & SPAN TRIM POTENTIOMETERS.
OPTIONAL EQUIPMENTFIELD WIRING
W970109DC
OPEN SW. CLOSE SW.
FIELD WIRING
1K POTENTIOMETER
ICI Indelac Controls, Inc.
JLR
12 & 24Vdc Modulating Actuator
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
33
+ - DCMOTOR
CAM CAM
SW.#1
SW.#2
1 2 3 4 5 6
COIL
DC VOLTAGE
SPDT SWITCH SHOWN FORILLUSTRATION ONLY
REVERSING RELAY SUPPLIED BY CUSTOMER
-
+
FIELD WIRING
OPERATION:POWER TO 1 & 2 FOR CCW ROTATIONPOWER TO 3 & 4 FOR CW ROTATIONTERMINALS 5 & 6 FOR FIELD LIGHTINDICATION CONNECTION
SW.#1
SW.#2
SWITCH #1 OPEN SWITCHSWITCH #2 CLOSE SWITCH
ACTUATOR SHOWN INOPEN POSITION
10-4-2001
COM COM
NCNONCNO
C
NO NC
C
NO NC
W011004DC
ICIIndelac Controls, Inc. Florence, KY 41042
WIRING DIAGRAM FOR TWO POSITION S & RSERIES ELECTRIC ACTUATOR 12 OR 24VDC
JLR
FIELD WIRING
5 6
DC VOLTAGE
SPDT SWITCH SHOWN FORILLUSTRATION ONLY
-
+
FIELD WIRING
SW.#2 CLOSE SW.
SW.#1 OPEN SW.
ACTUATOR SHOWN INOPEN POSITION
ICIIndelac Controls, Inc. Florence, Ky. 41042
JLR 4-1-03
7 8 9 10C NO NC C NO NC
SW#3 OPTION SW#4 OPTION
SW.#3 CLOSE AUX. SW.
SW.#4 OPEN AUX. SW.
OPERATION:POWER TO 1 & 2 TO OPEN (CCW)POWER TO 1 & 3 TO CLOSE (CW)5, 6 & 7 AUX. SW. FOR CLOSE POSITION8, 9 & 10 AUX. SW. FOR OPEN POSITION
NOTE:AUXILIARY SWITCHES ARE OPTIONALACTUATOR IS AVAILABLE WITH ONE ORTWO AUXILIARY SWITCHES
+ - DCMOTOR
CAM CAM
SW.#1 SW.#2
1 2 3 4
COIL
REVERSINGRELAY9 12
4815
W030401
13 14
WIRING DIAGRAM FOR S SERIES WITH DCMOTOR, REVERSING RELAY & 2 AUXILIARYSWITCHES
Two Position DC Actuator
Two Position DC Actuator with Reversing Relay
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
34
1 5 8 4
129
13 14
CAMCAM
RELAY
1 2 3 4 5 6
PSCMOTOR
SW.#1 SW.#2
NEU. HOT
ACTUATOR SHOWN IN THE OPEN POSITION
115V POWER SUPPLY
OPERATION:
CONNECTION:SUPPLY POWER TO T1 & T2T3 & T4 SUPPLIED FOR LIGHT INDICATION.
WHEN SPST SWITCH IS CLOSED THE ACTUATOR IS ACTIVATED ANDWILL OPEN AND CLOSE AS SET USING THE DIP SWITCHES ON THETIMER. THE CYCLE WILL REPEAT UNTIL POWER IS DISCONNECTED.
ACTUATOR
FIELDWIRING
3-26-02 W040204
2
1
3
SPST ON/OFF SWITCHSHOWN FOR ILLUSTRATIONONLY
BLK
BLK
WHT
TIMERYEL
ORG
WHT
BLU
RED
BLK BLK
GRN
RED
2 1 3
ONTIME
OFFTIME
OFF ON OFF ON
.1
.2
.4
.8
1.6
3.2
6.4
12.8
25.6
51.2
.1
.2
.4
.8
1.6
3.2
6.4
12.8
25.6
51.2
ADD ON TIME SELECTIONS6.3 SECONDS OR MINUTES
ADD ON TIME SELECTIONS21.6 SECONDS OR MINUTES
SECONDS/MINUTES
IN ADDITION TO ACTUATOR CYCLE TIME
TIMER
AVAILABLE SPEED OPTIONS:MODEL TIMINGCTBA12 ON .1 TO 102.3 SEC., OFF .1 TO 102.3 MIN.CTBA13 ON .1 TO 102.3 SEC., OFF 1 TO 1023 MIN.CTBA22 ON .1 TO 102.3 MIN., OFF .1 TO 102.3 MIN.CTBA23 ON .1 TO 102.3 MIN., OFF 1 TO 1023 MIN.CTBA33 ON 1 TO 1023 MIN., OFF 1 TO 1023 MIN.CTBA44 ON .25 TO 255.75 HRS., OFF .25 TO 255.75HRS.
ONTIME
OFFTIME
WIRING DIAGRAN FOR ELECTRIC ACTUATORWITH TIMER
ICI Indelac Controls, Inc.
JLR
CAPACITOR
7 108 9
FIELD WIRING
Actuator with Timer
1 2 3 4 5 6
N HOT
A.C.SUPPLYPOWER
DPDT CONTROL SWITCH SHOWNFOR ILLUSTRATION ONLY
FIELD WIRING
PSCMOTOR
CAPACITOR
SW.#2 SW. #1
WIRING DIAGRAN FOR A.C. ELECTRICACTUATOR WITH SPEED CONTROLILLUSTRATING SEVERAL COMMON OPTIONS
JLR 7-13-03
W030713
ICI
Indelac Controls, Inc. Florence, Ky. 41042
NOTES:POWER TO TERMINALS 1 & 2 OPENS THE VALVE (CCW ROTATION).POWER TO TERMINALS 1 & 3 CLOSES THE VALVE (CW ROTATION).TERMINALS #4 & #5 FOR LIGHT INDICATION.HOT TO TERMINAL 6 POWERS SPEED CONTROL.TERMINALS 7 THRUGH 10 FOR AUXILIARY SWITCH CONNECTIONS WHEN SUPPLIED.
WIRING DIAGRAM ILLUSTRATES THE ACTUATOR IN THE OPEN POSITION
OPTIONAL EQUIPMENT FIELD WIRING
GROUNDSCREW
OPTIONALBRAKE
SW. #1 CLOSE LIMIT
SW. #2 OPEN LIMIT
SWITCH LAYOUT
OPTIONALHEATER &THERMOSTAT
3
1
2
SPEEDCONTROL
NO NC
C
2 1 3
ONTIME
OFFTIME OFF ON OFF ON
.1
.2
.4
.8
1.6
3.2
6.4
12.8
25.6
51.2
.1
.2
.4
.8
1.6
3.2
6.4
12.8
25.6
51.2
ADD ON TIME SELECTIONS6.3 SECONDS OR MINUTES
ADD ON TIME SELECTIONS21.6 SECONDS OR MINUTES
SECONDS/MINUTES
IN ADDITION TO ACTUATOR CYCLE TIME
OPERATION: UPON APPLICATION OF POWER TOTERMINALS #1 AND #2 THE SPEED CONTROL PULSESPOWER TO THE ACTUATOR MOTER AS DETERMINEDBY THE SELECTION OF THE ON AND OFF TIME. ATTHE END OF TRAVEL THE LIMIT SWITCH TURNS OFFPOWER TO THE MOTOR. UPON APPLICATION OFPOWER TO TERMINALS #1 AND #3 THE SPEEDCONTROL AGAIN PULSES POWER TO THE MOTORUNTIL THE LIMIT SWITCH CUTS OFF THE POWER TOTHE MOTOR.
SPEED CONTROL
C
NO NC
AVAILABLE SPEED OPTIONS:MODEL TIMINGRS4A11 ON .1 TO 102.3 SEC., OFF .1 TO 102.3 SECRS4A12 ON .1 TO 102.3 SEC., OFF .1 TO 102.3 MINRS4A21 ON .1 TO 102.3 MIN., OFF .1 TO 102.3 SECRS4A22 ON .1 TO 102.3 MIN., OFF .1 TO 102.3 MIN
ONTIME
OFFTIME
Actuator with Speed Control
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
35
NO NC
C
NO
C
NC NO NC
C
NO NC
C
OPEN
CLOSE
GRN
RED
1 2 3 4 5 6 7 8 9 10
N HOT
120Vac/60hz/1ph FROM POWER SUPPLY
ICI Indelac Controls, Inc.
WIRING DIAGRAM FOR CONTROLPANEL PBOC-10
JLR 5-24-05 W050524
1 2 3 4 5 6 7 8 9 10
GROUNDSCREW
ACTUATOR
1 2 3 4 5 6 7TERMINAL STRIP #2
TERMINAL STRIP #1
PBOC-10CONTROL
PSC MOTOR
BRAKEOPTIONAL
CAPACITOR AUXILIARY SWITCHES
CLOSE LIMITSWITCH
OPEN LIMITSWITCH
HEATER & THERMOSTATOPTIONAL
HEATER &THERMOSTATOPTIONAL
FIELD WIRING
FIELDWIRING
OPEN/CLOSEMECHANICALLYINTERLOCKEDMAINTAINEDPUSH BUTTON
BLK
BLK
WHT
8 9 10
NOTE:ACTUATORS WITHOUT AUXILIARYSWITCHES DO NOT REQUIRE HOTCONNECTED TO TERMINAL 4 TERMINALSTRIP #2 OF PBOC-10 CONTROL BOX.LIGHT INDICATION AT CONTROL BOX ISACCOMPLISHED BY CONNECTING T4 OFACTUATOR TO T5 (OPEN) TERMINAL STRIP#2 IN CONTROL BOX AND T5 IN ACTUATORTO T7 (CLOSE) TERMINAL STRIP #2 INCONTROL BOX.
OPTIONAL EQUIPMENTFIELD WIRING
3
6
9
2
5
8
1
4
7
B A
+
+
-
- -
+
NEU.
HOT
1 2 3 4 5 6
BATTERY INVERTER
CHARGER
ON/OFFSWITCH
RELAY
WHT
WHT
BLK
RED
BLK
BLK WHT
BLK
RED
BLK
BLK
BLK
WHT
1 2 3NEU
OPEN
CLOSE
ACTUATOR
FIELDWIRING
SPDT CONTROL SWITCH SHOWNFOR ILLUSTRATION ONLY
IC
IIndelac Controls, Inc. Florence, Ky. 41042
WIRING DIAGRAM FOR ELECTRICFAIL-SAFE DEVICE 120VAC-1PHSUPPLY POWER
8-15-03 JLR
GRN
NOTES:ACTUATOR SHOWN TO FAIL TO CLOSEPOSITION.
T1 = NEUTRALT2 = 120V-1PH SUPPLYT3 = NEUTRAL, OUTPUTT4 = 120V-1PH OUTPUT POWERT5 = 120V-1PH BACKUP POWERT6 = NOT USED
BACKUP POWER IS SQUARE SINE WAVE.
RED
ELECTRICFAIL-SAFEDEVICE
W030815FS
7 8 9 10
FIELD WIRINGOPTIONAL
NOTE:INVERTER SWITCH IS TURNED OFF DURINGSHIPMENT, TURN INVERTER SWITCH TO ONPOSITION OR SYSTEM WILL NOT OPERATECORRECTLY.
BLK HEATER &
THERMOSTATOPTIONAL
120VAC
SUPPLY
N HOT
Battery Back Up Fail-Safe Device
On/Off Control
ICI Indelac Controls, Inc. Florence, KY 41042 Toll free 1-800-662-9424 Fax 859-727-4070
36
37
38
Torque (T) is any force about a given axis that produces rotation as a
moment. The magnitude of the moment is the product of the force (F) and
the perpendicular distance (D) from the line of action of the force to the axis,
T=F x D.
Simply put torque is generated by a twisting force which produces rotation
about an axis.
Torque conversions
Ft-Lb In-Lb Nm
1 12 1.36
5 60 6.80
10 120 13.60
20 240 27.20
40 480 54.40
80 960 108.80
100 1200 136.00
200 2400 272.00
400 4800 544.00
600 7200 816.00
800 9600 1088.00
1000 12000 1360.00
𝐹𝑡−𝐿𝑏 ∗ 12 = 𝐼𝑛−𝐿𝑏 𝐼𝑛−𝐿𝑏 ∗ .113 = 𝑁𝑚 𝐹𝑡−𝐿𝑏 ∗ 1.36 = 𝑁𝑚
39
Duty cycle is the ratio of actuator on time to off time and is used to
determine the proper actuator for a specific application. It is also used to
determine an acceptable operating time so that the thermal over load in
the motor is not exceeded during valve or damper automation. Actuator
inefficiencies cause the motor temperature to rise and at a critical
temperature the thermal over load is activated and the actuator is shut
down. The actuator is inoperative (undesirable in most applications) for a
period of time allowing the motor to cool and the thermal over load to
reset. Duty Cycle = DC, On Time = ON and Off Time = OFF
DC = (ON/ON + OFF) x 100
For example: ICI’s standard model SD has a 5 second cycle time and is
rated at 25% duty cycle. This means that the off time must be at least 15
seconds, hence: ON = 5, OFF = 15
DC = (5/5+15) x 100
DC = (5/20) x 100
DC = 0.25 x 100
DC = 25%
Model SD with an extended duty motor has a 10 second cycle time and is
rated at 75% duty cycle. This means that the off time must be at least
3.333 seconds, hence: ON = 10, OFF = 13.333
DC = (10/10+3.333) x 100
DC = (10/13.333) x 100
DC = 0.75 x 100
DC = 75%
This formula can be used to determine the off time of an actuator if the
cycle time and duty cycle are known. OFF = (ON/DC)-ON
40
ICI manufactures compact quarter turn electric actuators. The word
compact defines the torque range below 10,000 lb-in (1130 Nm). While
we do offer larger torque actuators and different style actuators like
multi-turn actuators (actuators rotating more than 360 degrees) and linear
actuators (actuators drive that move axially instead of rotary) our niche is
in the compact quarter turn market. ICI actuators are used for on-off
service (valve operated to full open/close position to start or stop flow) as
well as modulating service (valve positioned to throttle or regulate flow).
In the electric actuator world a limit switch is the device that controls the
end position of the actuator, the actuator limits. This term is often
confused with a limit switch that is used on pneumatic actuators to
transmit valve position. When using electric actuators the “pneumatic
limit switch option” is known of as auxiliary switches, extra limit
switches or auxiliary limit switches. Contrary to pneumatic actuators
where the limit switch is mounted externally with an electric actuator the
auxiliary limit switches are installed inside the actuator enclosure.
Actuator limits for compact quarter turn electric actuators are normally 0
(closed) and 90 (open) degrees.
ICI electric actuators are equipped with manual over rides. A manual
over ride allows the user to rotate the valve manually in the event of a
power failure. Our 400 lb-in (45.2 Nm) actuators and larger are equipped
with declutching manual over rides. Declutching manual over rides
disengage from the gear train enabling the user to turn the valve with
greater ease.
ICI also manufactures a line of electric fail-safe devices which are battery
back up systems that invert 12Vdc battery power to 115Vac square sine
wave power upon unexpected loss of main supply power allowing
standard actuators to operate valves open or close in an emergency.
41
42
ISO 5211:2001(E)
The a dimensions below were taken from the International Standard ISO
5211 First edition 2001-02-15 and are only a small representation of the
information available in International Standard ISO 5211.
Flange Type Female Drive Bolt Circle
F03 9mm (.354" Sq.) 36mm (1.417" Sq.)
F04 11mm (.433" Sq.) 42mm (1.654" Sq.)
F03/F04 (Not an ISO Flange) 9mm (.354" Sq.) 42mm (1.654" Sq.)
F05 14mm (.551" Sq.) 50mm (1.969" Sq.)
F07 17mm (.669" Sq.) 70mm (2.756" Sq.)
F10 22mm (.866" Sq.) 102mm (4.016" Sq.)
F12 27mm (1.063" Sq.) 125mm (4.921" Sq.)
F14 36mm (1.417" Sq.) 140mm (5.512" Sq.)
F16 46mm (1.811" Sq.) 165mm (6.496" Sq.)
F25 55mm (2.165" Sq.) 254mm (10.000" Sq.)
F30 75mm (2.953" Sq.) 298mm (11.732" Sq.)
43
TYPE 1 General purpose intended for indoor use to prevent accidental
contact with enclosed equipment.
TYPE 4 Water and dust tight intended for indoor or outdoor use to
protect enclosed equipment from splashing water, seeping of,
falling or hose directed water and severe external
condensation, they are sleet proof.
TYPE 4X Water and dust tight with same provisions as Type 4 enclosure
but also are corrosion resistant.
TYPE 6 Water and dust tight sleet resistant intended for indoor or
outdoor use where occasional submersion may be
encountered with a static head of no more then 6 feet for no
longer then 30 minutes.
TYPE 7 Class I, Division 1 and 2, Groups A, B, C or D intended for
indoor hazardous locations. Division 1: Hazardous vapors are
present. Division 2: Hazardous contained but may not be
present. Groups A, B, C & D classifies different gases and vapors.
TYPE 9 Class II, Division 1 and 2, Groups E, F or G intended for
indoor hazardous locations. Division 1: Air suspended dust.
Division 2: Surface accumulated non-air suspended. Groups E,
F & G classifies different dust types.
IP Code Minimum NEMA
Enclosure Rating
I P 6 5 4 , 4 X
I P 6 7 6
I P 6 8 6 P
44
Epoxy Hybrid Aromatic
Urethane
Aliphatic
Urethane
TGIC
Polyester
Polyester
Wrinkle
Non-TGIC
Polyester
Hardness
Flexibility
Overbake Stability
Exterior Durability
Corrosion Protection
Chemical/Solvent Resistance
Ease of Application
Not Good Fair Good Very Good Best
45
The powder coating used on all ICI electric actuators must:
1. Be Corvel Royal Blue #20-5005 or equivalent.
2. Be TGIC Polyester
3. Have excellent gloss pretension.
4. Provide excellent adhesion.
5. Provide good edge coverage and chip resistance.
6. Provide excellent exterior durability and resistance to the
suns UV rays.
7. Provide good salt spray protection.
8. Provide flexibility and hardness to assure protection
against high impact.
9. Offer a high degree of resistance to corrosion.
10. Offer a high degree of protection against chemicals and
solvents.
*The binder is the all important solid material that forms the
bulk of the powder coating. The above graphic representation
gives the relative properties of some common powder binder
types.
Note: 24Vac units are 24Vdc motors rectified for 24Vac use.
FL=Full Load Current, LR=Lock Rotor Current
12Vdc 24Vdc 24Vac 115V-1Ph 230V-1Ph 230V-3Ph 460V-3Ph
Model FL LR FL LR FL LR FL LR FL LR FL LR FL LR
R 0.6 2.9 0.4 2.4 0.4 2.4 0.55 0.38 N/A N/A N/A N/A
SR 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A
SX 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A
SD 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A
SDX 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A
MR 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A
MS 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A
ML 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A
MH 1.4 4.2 0.8 3.2 0.8 3.2 0.75 0.38 N/A N/A N/A N/A
LA 6.9 48 3.7 25 3.7 25 0.98 1.5 1.03 2.4 N/A N/A N/A N/A
LX 6.9 48 3.7 25 3.7 25 1.09 2.9 1.03 2.4 N/A N/A N/A N/A
5K 6.9 48 3.7 25 3.7 25 1.09 2.9 1.03 2.4 1.26 4.3 0.5 1.9
7K 6.9 48 3.7 25 3.7 25 2.8 7.1 1.03 2.4 1.26 4.3 0.5 1.9
12K 2.8 7.1 1.03 2.4 1.26 4.3 0.5 1.9
14K 2.8 7.1 1.03 2.4 1.26 4.3 0.5 1.9
27K 2.8 7.1 1.03 2.4 1.26 4.3 0.5 1.9
46
ORDERING INFORMATION WHEN ORDERING PLEASE SPECIFY THE FOLLOWING:
1. QUANTITY REQUIRED
2. MODEL NUMBER OR ACTUATOR SERIES
3. ENCLOSURE RATING
• NEMA TYPE 4
• NEMA TYPE 4X
• NEMA TYPE 7
• NEMA TYPE 4 & 7
4. ELECTRICAL REQUIREMENTS
• VOLTAGE
• HERTZ
• PHASE
5. OUTPUT TORQUE
• ALLOW 25% SAFETY FACTOR
6. OPTIONAL EQUIPMENT REQUIRED
• OPTIONS ARE AVAILABLE FOR MOST APPLICATIONS,
IF YOU HAVE QUESTIONS REGARDING THE
APPLICATION PLEASE CONTACT OUR SALES
SPECIALIST.
7. DESIRED SHIP DATE
• IF WE KNOW YOUR SCHEDULE WE WILL TRY TO MEET
IT, IF WE DO NOT THE ORDER WILL DEFAULT TO OUR
SCHEDULE.
ICI SALES TEAM
US SALES
DEBBIE VOGES EXT: 100
INTERNATIONAL SALES
MATT ROBINSON EXT: 109
CUSTOMER SERVICE
BOB KRAMER EXT: 108
GENERAL CONTACT
PHONE
1 - 8 5 9 - 7 2 7 - 7 8 9 0
TOLL FREE PHONE
1 - 8 0 0 - 6 6 2 - 9 4 2 4
FAX
1 - 8 5 9 - 7 2 7 - 4 0 7 0
ADDRESS
6810 POWERLINE DR.
FLORENCE KY, 41042
USA
VISIT US ONLINE!
w w w. i n d e l a c . c o m
RECOMMENDED SPARE PARTS
1. One set of limit switches.
2. Capacitors for R through M Series.
3. Potentiometer for modulating actuators.