j:msu classroom remodel0.2 revit modelsreid 452mosaic architecture, p.c. 428 north last chance gulch...

26
420 418 419 417 416 415 413 412 409 408 407 405 414 411 431 423A 422 425 426 427 424 421A 421 428 429 432 434 435 436 437 451 450 449 448 447 446 445 444 443 442 441 440 430 458 454 455 456 457 446A 457A 402 401 404 453 459 460 438 433 406 410 403A 403 431A 425A 423 DN DN UP DN DN DN DN DN DN REID 452 PROJECT LOCATION 720 S. Tracy Ave., Bozeman, MT dRA-Architect.com dRA dennis Raffensperger Architect REV. DESCRIPTION DATE REVIEWED BY: DRAWN BY: SHEET DATE SHEET TITLE MONTANA STATE UNIVERSITY MSU-CPDC MONTANA STATE UNIVERSITY BOZEMAN, MONTANA PHONE: 406.994.5413 FAX: 406.994.5665 Consultant #: 1710 CLASSROOM RENOVATIONS 2018 REID HALL 452 100% CONSTRUCTION DRAWINGS MOSAIC DRA COVER A000 03/19/2018 PROJECT # 1 PPA#18-2011 CLASSROOM RENOVATIONS 2018 CLASSROOM: REID HALL 452 ROBERTS HALL 319 ROBERTS HALL 321 ADDRESS: MONTANA STATE UNIVERSITY BOZEMAN, MT 59717 PROJECT #1 1" = 20'-0" REF: 1/ A200 REID HALL FOURTH FLOOR VICINITY MAP 1 ARCHITECTURAL SHEETS A000 COVER A001 GENERAL & CODE INFORMATION A100 DEMO PLANS A101 FLOOR PLAN & REFLECTED CEILING PLAN & DETAILS A200 ELEVATIONS PROJECT DIRECTORY MECHANICAL/ELECTRICAL/ PLUMBING ENGINEERING: 2880 TECHNOLOGY BLVD. WEST P.O. BOX 1113 BOZEMAN, MT 59771 - 1113 (406) 587 - 0721 CONTACT: Erik Renna, P.E. erenna@m - m.net ARCHITECT: MOSAIC ARCHITECTURE, P.C. 428 North Last Chance Gulch Helena, MT 59601 Ph. 406 - 449 - 2013, CONTACT(S) : Matt Aune, [email protected] 720 S. TRACEY AVE BOZEMAN, MT (406) 581 - 8759 CONTACT: DENNIS RAFFENSPERGER AIA dennis@dra - architect.com dRA d ennis R affensperger CONSULTING ARCHITECT: MEP SHEETS E100 ELECTRICAL LIGHTING PLAN E200 ELECTRICAL POWER & SIGNAL PLAN M100 MECHANICAL PLAN

Upload: others

Post on 11-Feb-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • 420 418

    419

    417

    416

    415 413412 409 408 407 405

    414 411

    431

    423A

    422

    425

    426 427424

    421A

    421

    428 429 432 434 435 436 437

    451450

    449

    448

    447

    446

    445

    444

    443

    442

    441

    440

    430

    458

    454 455

    456457

    446A 457A

    402

    401

    404

    452

    453

    459

    460

    438

    433 406

    410

    403A403

    431A

    425A

    423

    DNDN

    UP DN

    DN

    DNDN

    DN

    DN

    REID 452

    PROJECT LOCATION

    72

    0 S

    . Tr

    acy

    Ave

    ., B

    ozem

    an, M

    T

    dRA-

    Arc

    hite

    ct.c

    om

    dRA

    den

    nis

    Raf

    fens

    perg

    erArc

    hite

    ct

    REV. DESCRIPTION DATE

    REVIEWED BY:DRAWN BY:

    SHEET

    DATE

    SHEET TITLE

    MO

    NT

    AN

    AST

    AT

    E U

    NIV

    ER

    SIT

    Y

    MSU-CPDCMONTANA STATE UNIVERSITY

    BOZEMAN, MONTANAPHONE: 406.994.5413

    FAX: 406.994.5665

    Consultant #:1710

    CL

    ASS

    RO

    OM

    RE

    NO

    VA

    TIO

    NS

    2018

    REI

    D H

    ALL

    45

    2 1

    00

    % C

    ON

    STR

    UC

    TIO

    N D

    RA

    WIN

    GS

    MOSAICDRA

    COVER

    A00003/19/2018

    PR

    OJE

    CT

    # 1

    PPA#18-2011

    CLASSROOM RENOVATIONS 2018

    CLASSROOM: REID HALL 452

    ROBERTS HALL 319 ROBERTS HALL 321

    ADDRESS:MONTANA STATE UNIVERSITY

    BOZEMAN, MT 59717

    PROJECT #1

    1" = 20'-0" REF: 1/ A200REID HALL FOURTH FLOOR VICINITY MAP1

    ARCHITECTURAL SHEETS

    A000 COVERA001 GENERAL & CODE INFORMATIONA100 DEMO PLANSA101 FLOOR PLAN & REFLECTED CEILING PLAN & DETAILSA200 ELEVATIONS

    PROJECT DIRECTORYPROJECT DIRECTORY

    MECHANICAL/ELECTRICAL/PLUMBING ENGINEERING:

    2880 TECHNOLOGY BLVD. WESTP.O. BOX 1113BOZEMAN, MT 59771-1113(406) 587-0721

    CONTACT: Erik Renna, [email protected]

    ARCHITECT:

    MOSAIC ARCHITECTURE, P.C.428 North Last Chance GulchHelena, MT 59601Ph. 406-449-2013,

    CONTACT(S) : Matt Aune, [email protected]

    720 S. TRACEY AVEBOZEMAN, MT (406) 581-8759

    CONTACT: DENNIS RAFFENSPERGER [email protected]

    dRAdennis Raffensperger

    CONSULTING ARCHITECT:

    MEP SHEETSE100 ELECTRICAL LIGHTING PLANE200 ELECTRICAL POWER & SIGNAL PLANM100 MECHANICAL PLAN

  • REFERENCE SYMBOLS:

    SCALE

    SECTIONS / WALL SECTIONS

    DETAIL CALLOUT

    INTERIOR ELEVATIONS

    ROOM NAME, NUMBER, AND AREA

    GRID LINES:NUMBERS LEFT TO RIGHTLETTERS TOP TO BOTTOM

    ELEVATION TAG,TYP. MAIN FLOOR = 100' - 0"

    DRAWING TITLE

    FIRE EXTINGUISHER, SEE CODE PLANS

    SHEET NUMBER

    DRAWING NUMBER

    SHEET NUMBER

    DRAWING NUMBER

    SHEET NUMBER

    DRAWING NUMBER

    FE

    FE

    WITH CABINET

    WALL-HUNG, NO CABINET

    A1-01

    13

    13

    13

    13

    View Name1/8" = 1'-0"23

    1

    A101 SIM

    A101

    1

    SIM

    Room name

    150 SF101

    ##

    ##

    NameElevation1

    A101 SIM

    Room name

    101150 SF

    1. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ALL CONDITIONS OF THE EXISTING SITE.

    2. RESPONSIBILITY FOR ON-SITE COORDINATION OF CONSTRUCTION ACTIVITIES IS WITH THE GENERAL CONTRACTOR.

    3. ALL SHOP DRAWING DIMENSIONS TO BE CHECKED AND VERIFIED IN THE FIELD BY THE CONTRACTOR WHO WILL BE RESPONSIBLE FOR SAME.

    4. GENERAL CONTRACTOR IS RESPONSIBLE FOR PATCHING OF ANY SURFACES DAMAGED DURING THE CONSTRUCTION PROCESSES. SURFACES ARE TO BE PATCHED FLUSH WITH EXISTING. MATCH EXISTING ADJACENT FINISH OR APPLY NEW FINISH AS SCHEDULED.

    5. GENERAL CONTRACTOR TO COORDINATE ALL CUTTING AND PATCHING REQUIRED BY WORK OF ALL TRADES AND AS APPROVED BY ARCHITECT/ ENGINEER.

    6. GENERAL CONTRACTOR TO PROVIDE ALL REQUIRED BLOCKING, ANCHORAGES FOR ACCESSORIES, MILLWORK, TRIM, GRAB BARS, CABINETS, SHELVING, TOILET ACCESSORIES, HANDRAILS, OTHER FLUSH OR SEMI-RECESSED EQUIPMENT, MECHANICAL AND ELECTRICAL ITEMS, OR AS SPECIFIED.

    7. IN GENERAL, REPETITIVE DETAILS DRAWN ARE SHOWN IN FULL ONLY ONCE. REPETITIONS MAY NOT BE COMPLETE IN EVERY DETAIL AS SHOWN IN THE ORIGINAL DETAIL.

    8. PARTITIONS ARE LOCATED BY ONE OF THE FOLLOWING METHODS:9. a) WHERE POSSIBLE, BY RELATIONSHIP TO ADJACENT STRUCTURE.10. b) TYPICAL RELATIONSHIP TO LARGE SCALE DETAILS.11. c) BY DIMENSION FROM STRUCTURE OR PARTITION ALREADY LOCATED.12. d) BY DIMENSION FROM GRID LINES.13. e) DIMENSIONS ARE TO FACE OF STUD.14. DIMENSIONS ARE SHOWN ON THE DRAWINGS. DO NOT SCALE THE DRAWINGS.15. ALL HEIGHTS ARE DIMENSIONED FROM THE TOP OF SUBFLOOR UNLESS NOTED OTHERWISE.16. EDGE TRIM AROUND ALL EDGES OF GYPSUM BOARD WALLS ABUTTING OTHER MATERIALS. LEAVE

    1/4" GAP FROM WALL FOR SEALANT.17. WHERE COLUMNS AND STUD WALLS ALIGN, GYPSUM BOARD TO BE CONTINUOUS OVER COLUMNS

    OR BOXED AROUND COLUMN IF COLUMN PROJECTS BEYOND WALL.18. GYPSUM BOARD IN TOILET AREAS AND OTHER AREAS INDICATED AS "WET AREAS" TO BE WATER

    RESISTANT GYPSUM BOARD.19. BRING TO THE ATTENTION OF THE ARCHITECT ANY CONDITION OR AREA OF FINISH THAT IS IN

    QUESTION OR NOT NOTED.20. SEAL OPENINGS IN FLOOR AROUND DUCTS, PIPES, VENTS, SOILPIPES, TRAPS, CONDUIT, ETC.

    ACCORDING TO DETAILS & SPECIFICATIONS.21. ALL PENETRATIONS THROUGH WALLS ABOVE CEILING AND BELOW STRUCTURE ARE TO BE CLOSED

    TIGHT AROUND PENETRATION. USE FIRESAFING WHERE FIRE-RATED WALLS AND FLOOR/CEILINGS ARE PENETRATED. SEE DETAILS AND SPECIFICATIONS.

    22. DUST BARRIERS MUST BE INSTALLED WHEREVER NEW WORK IS ADJACENT TO OCCUPIED AREAS. BARRIERS MUST BE SEALED TO INSURE NO DUST TRANSMISSION TO OCCUPIED SPACES.

    23. CONTRACTOR TO VERIFY ALL EQUIPMENT SIZES AND ROUGH-IN NEEDS AND ADJUST TO EXISTING CONDITIONS PRIOR TO BEGINNING WORK.

    24. SEE MECHANICAL & ELECTRICAL FOR ADDITIONAL PLACEMENT OF SLEEVES & HANGERS REQUIRED BY WORK.

    25. ALL MECHANICAL AND ELECTRICAL LINES TO BE INSTALLED TIGHT TO STRUCTURE WHERE POSSIBLE.

    26. HEATING, PLUMBING AND ELECTRICAL PLANS WHERE SHOWN DIAGRAMMATICALLY ARE INTENDED TO INDICATE CAPACITY, SIZE AND LOCATION AND GENERAL ARRANGEMENTS. ALL NECESSARY FEATURES OF RELATED CONSTRUCTION WILL BE REQUIRED AS IF SHOWN IN DETAIL.

    27. WHERE MECHANICAL AND ELECTRICAL EQUIPMENT LOCATIONS CONFLICT ELECTRICAL, LIGHT FIXTURE LOCATIONS SHALL TAKE PRECEDENCE.

    28. WHERE PLUMBING OCCURS IN STUD WALL WITH HORIZONTAL OR VERTICAL PIPING, STUDS SHALL BE CONSTRUCTED DEEP ENOUGH TO ACCOMMODATE PIPING. SAME FOR ALL ELECTRICAL PANELS.

    29. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NEW MATERIALS (U.N.O.) AND QUALIFIED CRAFT PERSONS TO COMPLETE THE WORK.

    30. CONSTRUCTION DOCUMENTS SHOW THE DESIGN INTENT OF THE PROJECT AND MAY NOT SHOW MINOR DETAILS OF PROPOSED INSTALLATIONS. THE INCLUSION OF THESE MINOR DETAILS IS IMPLIED TO PROVIDE A COMPLETE PROJECT AND ARE TO BE INCLUDED AS A PART OF A BID.

    31. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSPECT EXISTING CONDITIONS PRIOR TO PROCEEDING WITH EACH INSTALLATION OR PART OF THE WORK. DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT PRIOR TO PROCEEDING.

    32. THE GENERAL CONTRACTOR IS TO COORDINATE THE INSTALLATION OF MATERIALS AND WORK OF OTHERS WHO ARE NOT SUB-CONTRACTORS TO THE G.C., YET ARE REQUIRED TO PROVIDE A COMPLETED PROJECT. AREAS OF WORK REQUIRING COORDINATION INCLUDE BUT ARE NOT LIMITED TO THOSE INDICATED AS N.I.C. ON THE CONSTRUCTION DOCUMENTS.

    33. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR COORDINATION OF WORK.34. IN THE CASE OF CONTRADICTIONS BETWEEN DRAWINGS OR BETWEEN DRAWINGS AND

    SPECIFICATIONS, ASSUME THE MORE COSTLY APPROACH FOR BIDDING PURPOSES. BRING ALL CONTRADICTIONS TO THE ATTENTION OF THE ARCHITECT.

    35. THE CONSTRUCTION DOCUMENTS CONSIST OF THE CONSTRUCTION DRAWINGS AND SPECIFICATIONS INCLUSIVELY. SOME ITEMS MAY BE SHOWN ONLY ON THE DRAWINGS, OR INDICATED ONLY IN THE SPECIFICATIONS. FOR EXAMPLE, THE SPECIFICATIONS MAY SAY TO PAINT ALL EXPOSED STRUCTURAL STEEL, BUT THIS MAY NOT BE CALLED OUT ON ALL OF THE DRAWINGS.

    36. ALL WORK SHALL COMPLY WITH STATE AND LOCAL CODES. CONTRACTOR SHALL INSURE FULL COMPLIANCE WITH FLAME SPREAD REQUIREMENTS.

    37. CONTRACTOR SHALL PROMPTLY REMOVE ALL WASTE MATERIALS AND LEAVE PREMISES AND SITE CLEAN.

    38. THE CONTRACTOR SHALL PROVIDE ALL CEILING AND/OR WALL ACCESS PANELS/DOORS AS REQUIRED BY THE AIR CONDITIONING, PLUMBING & ELECTRICAL SYSTEMS, PROVIDE APPROVED ASSEMBLIES W/ SELF-CLOSING DEVICES IN RATED CONSTRUCTION. (PAINT TO MATCH ADJACENT WALL COLOR)

    39. ALL PENETRATIONS OF FIRE RESISTIVE CONSTRUCTION SHALL BE PROTECTED WITH APPROVED FIRE ASSEMBLIES.

    40. ELECTRICAL OUTLETS AND LIGHTING ARE ONLY SHOWN SPORATICALLY ON ARCHITECTURAL "A" SHEETS WHERE PLACEMENT OF SUCH IS CRITICAL TO PARTICULAR AESTHSTICS. ELECTRICAL INDICATIONS ON "A" SHEETS ARE NOT MEANT TO BE COMPLETE OR EXAUSTIVE. SEE ELECTRICAL DRAWINGS FOR ALL ELECTRICAL AND DATA FEATURES.

    DRAWING SET NOTE: THESE DRAWINGS ARE TO BE UTILIZED AS A COMPLETE SET FOR BIDDING AND CONSTRUCTION. INDIVIDUAL SECTIONS OF DRAWINGS SHOULD NOT BE SEPARATED FROM THE ENTIRE SET. IMPORTANT NOTES FOR ONE AREA OF WORK MAY BE INCLUDED IN OTHER AREAS IN THE DRAWINGS. ALL CONTRACTORS AND SUPPLIERS MUST REVIEW ENTIRE DRAWING SET AND SPECIFICATIONS.

    GENERAL NOTES:

    THE GENERAL CONDITIONS TO THE CONTRACT FOR THE CONSTRUCTION OF BUILDINGS: THE MONTANA STATE UNIVERSITY GENERAL CONDITIONS TO THE CONTRACT FOR CONSTRUCTION, HEREINAFTER REFERRED TO AS THE GENERAL CONDITIONS, IS HEREBY MADE A PART OF THE ARCHITECTURAL SPECIFICATIONS.1. CONTRACT DOCUMENTS INCLUDE THE ARCHITECT'S DRAWINGS, SPECIFICATIONS, GENERAL

    CONDITIONS, AGREEMENT (BUILDING CONTRACT) AND ALL ADDENDA. THEY ARE TO INCLUDE ALL LABOR, EQUIPMENT, AND MATERIALS NECESSARY FOR THE PROPER EXECUTION OF THE WORK EXCEPT AS MAY BE SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS OR FOR WHICH SEPARATE PRICES MAY BE ASKED IN THE BID PROPOSAL.

    2. REGULATIONS, TAXES AND PERMITS: THE WHOLE OF THE WORK IS TO BE EXECUTED IN STRICT ACCORDANCE WITH THE REGULATIONS AND CODES OF THE GOVERNMENTAL AGENCIES WHOSE JURISDICTION IS APPLICABLE.

    GENERAL CONDITIONS:

    IN inchINCL includedINFO informationINSUL insulationINT interiorIWA/IW interior wall assemblyJAN janitorJST joistJT jointLAV lavatoryLF lineal footLTG lightingLVR louverM men'sMNFR/MANUF. manufacturerMAT materialMAX maximumMECH mechanicalMC medicine closetMDF medium density fiber boardMEMB membraneMEZZ mezzanineMH man holeMIN minimumMIRR mirrorMISC miscellaneousMO masonry openingMTL metalMULL mullionN northNA not applicableNAT naturalNIC not in contractNO numberNTS not to scaleOA over allO.C. on centerOD outside diameterOH overhead/opposite handOPNG openingOPP oppositePART.BD. particle boardPART’N/PART partitionPC precast concretePL platePLAM plastic laminatePLAST plasticPLWD plywoodPND paper napkin dispenserPNL panelPR pairPSL parallel strand lumberPT pointPTD paper towel dispenserPTD/R paper towel dispenser/receptaclePVMT pavementP.V.C. polyvinylchlorideQTY quantityR/RAD radiusR riserRA roof/ceiling assemblyRB rubber baseRD roof drainRDWD redwoodRE regardingREC recessedREF referenceREFR refrigeratorREINF reinforcingREQD/REQ requiredRES resilientRM roomRO rough openingRV roof ventR&S rod and shelfS southSACT suspended acoustical ceiling tileSAT suspended acoustical tile ceilingSC solid coreSCD seat cover dispenserSCHED scheduleSD soap dispenserSECT sectionSF square feetS.G. supply grillSGL safety glassSHLVS shelvesSHLVNG shelvingSHT sheetSHTG sheathingSHWR showerSIM similarSIM. similarS.I.P. structural insulated panelSLNT sealantSM surface mountedSOG slab on gradeS.STL./SS stainless steelS&P shelf and poleSPEC specificationsSS service sinkSTD standardSTL steelSTOR storageSTRUCT/STRUC structuralSUBFLR subfloorSUSP suspendedS&V stain and varnishSV sheet vinylSY square yardT tread/thermostatTB towel barTEL telephoneTEMP temperatureT&G tongue and grooveT.ALUM. tubular aluminumT.B. test boreTHK thickTHRU throughT.J.I./TJI Truss Joist IncorporatedT.O. top ofT.O.B. top of beamTOC top of concreteT.O.P. top of plateT.O. FTG top of footingT.O.S. top of steelT.O. SL. top of slabT.O.W. top of wallTP toilet paper holderTPD toilet paper dispenserTPG toppingTR/TRD treadT.S. tubular steelTV televisionTYP typicalUBC uniform building codeUG undergroundUH unit heaterUNO unless noted otherwiseUR urinalUV unit ventilatorVAC vacuum outletVAR variesVB vapor barrierVCT vinyl composition tileVEN veneerVERT verticalVEST vestibuleVG vertical grainVIN vinylVP veneer plasticVT vinyl tileVWC vinyl wall coveringW west/women/widthW/ withW/O with outWB wood baseWC water closetWD woodW/D washer/dryerWGW windowWGL wire glassWH water heaterWM wire meshWNDW/WDW windowWP waterproofWR water resistantWS weatherstripWSCT wainscotWT weightWWF welded wire fabricWWM welded wire meshX byYH yard hydrantYD yard

    @ atA.B. anchor boltAC asphaltic concreteA/C air conditioningACC PNL access panelACOUST acousticalACT acoustical ceiling tileAD area drainADJ adjacentA.F.F. above finished floorA.I.B. air infiltration barrierALT alternateALUM aluminumANOD anodizedAPPROX approximateAPPRD approvedARCH architectAUTO automaticBBD bulletin boardBD boardBITUM bituminuousBL building lineBLDG buildingBLK blockBLKG blockingBLDG buildingBLKG blockingBM beam/bench markBO by ownerB.O. bottom ofBOT bottomBRK brickBRG bearingB/S building standardBSBD baseboardBTW betweenBTM/BOTT bottomBTWN betweenB.O.W. bottom of wallBU built upCAB cabinetCAP capacityCB catch basinCBD chalk boardCB-ICF cement based insulated concrete formCD ceiling diffuserC.F. cement fiber (siding and trim)/cubic feetCL centerlineC.B. catch basinC.C. center to centerCDX exterior grade plywoodC.T. ceramic tileCG ceiling grill/corner guardCH channelCI cast iron/cubic incheseCJ control jointCLG ceilingC.L.L. contract limit lineCL center lineCLO closetCLR clearCMU concrete masonry unitCMNT cementCMT ceramic mosaic tileCO clean outCOL/COLS column/columnsCONC concreteCOND conditionCONF conferenceCONN connectionCONST constructionCTRD centeredCONT continuousCONTR contractorCORR corridorCPT carpetCR ceiling registerCT ceramic tileCTR counterCUH cabinet unit heaterCW cold waterCY cubic yardDBL doubleDEPT departmentDF drinking fountainDIA diameterDIAG diagonalDIM dimensionDISP dispenserDL dead loadDN downDP demountable partitionDR doorDWR drawerDS downspoutDTL/DET detailDWG drawingE eastEA eachEIFS exterior insulation finish systemE.J. expansion jointEL/ELEV elevation - height/elevatorELEC electricalENCL enclosureEO electrical outletEP electrical panelEQ equalEQUIP equipmentEWC electrical water coolerEWH electrical water heater(E)/EXIST existingEWC electrical water coolerEWH electrical water heaterEXH exhaustEXP expansionEXT exteriorEWA/EW exterior wall assemblyFA fire alarm/floor-ceiling assemblyFABR fabricateFAH fire alarm hornFAS fire alarm stationFBR face brickFD floor drainFDN/FDTN foundationFFHB frost free hose bibFG finish gradeFH fire hydrantFIN. FLOOR top of floor sheathingFIN finishFIO furnished and installed by ownerFIX/FXTR fixtureF.O. face ofFDN foundationFEC fire extinguisher cabinetFF finished floorFLR/FL floorFLUOR fluorescentFND feminine napkin dispenser/disposalFOC face of concreteFOIC furnished by owner and installed byFOS face of studFOW face of wallFT foot or feetFTG footingFTIC furnished by tenant & installed by contractorFE fire extinguisherGA gaugeGB grab barGAF brand name roofing productGALV galvanized G.C. general contractorGEN generalGI galvanized ironGL glassGLU LAM or G.L.B. glue laminated beamGRD grade/gridGS galvanized steelGWB gypsum wall boardGYP gypsumHB hose bibHC hollow core/handicappedHD BD Hard boardHDR headerHOR horizontalHP high pointHR hourHT heightHTG heatingHVAC heating, ventilation, air conditioningHW hot water

    ABBREVIATIONS: SUMMARY CODE REVIEW SEE CODE PLAN, THIS SHEET

    OCCUPANCY CLASSIFICATION: BUSINESS GROUP BEDUCATIONAL OCCUPANCIES FOR STUDENTS ABOVE 12TH GRADE

    TYPE OF CONSTRUCTION: 3B

    SPRINKLER SYSTEM: NONE EXISTING NONE PROPOSED

    PROPOSED SIZE:MAINTAIN EXISTING SIZE 968 SQ FT

    OCCUPANT LOADS:BUILDING SPACES:THIS PROJECT IS NOT CHANGING BUILDING AREA OR OCCUPANCY TYPE. THEREFORE IS NOT INCREASING OCCUPANT LOAD

    BUILDING SUMMARY

    THIS PROJECT SHALL COMPLY WITH THE LATEST EDITION OF CODES ADOPTED BY THE STATE OF MONTANA AND THE CITY OF BOZEMAN:

    2012 International Building Code (IBC)2012 International Mechanical Code (IMC)2012 International Fuel Gas Code (IFGC)2012 Uniform Plumbing Code (IAMPO)2014 National Electrical Code (NEC)2012 International Fire Code (IFC)2012 International Energy Conservation Code (IECC)

    APPLICABLE BUILDING CODES

    Project Description:CLASSROOM REMODEL AT THE MONTANA STATE UNIVERISTY

    EXITING, Main Floor:THIS PROJECT IS AN INTERIOR REMODEL PROJECT AND MEETS DEFINITON OF IEBC LEVEL 2 ALTERATION (Section 805 Means of Egress, Section 805.1 Scope)

    EXIT ACCESS ARRANGEMENTRequirements for Level 2 alteration does not apply as 3rd floor of building is occupied by single tenant.

    TRAVEL DISTANCESection 805.4.1.1 Occupant load and travel distance: In any work area, all rooms and spaces having an occupant load greater than 50 or in which the travel distance to an exit exceeds 75 feet shall have a minimum of two egress doorways- does not apply.

    MEANS OF EGRESSSection 704.1 Means of Egress General: Alterations shall be done in a manner that maintains the level of protection provided for the means of egress.The existing means of egress is being remodeled to satisfy ADA requirements only; Approximate location will remain the same.

    EXIT SIGNSTHIS PROJECT IS NOT CHANGING EXISTING EXIT SIGNS.

    A B

    2

    1

    C

    3

    968 SF

    REID

    452

    72

    0 S

    . Tr

    acy

    Ave

    ., B

    ozem

    an, M

    T

    dRA-

    Arc

    hite

    ct.c

    om

    dRA

    den

    nis

    Raf

    fens

    perg

    erArc

    hite

    ct

    REV. DESCRIPTION DATE

    REVIEWED BY:DRAWN BY:

    SHEET

    DATE

    SHEET TITLE

    MO

    NT

    AN

    AST

    AT

    E U

    NIV

    ER

    SIT

    Y

    MSU-CPDCMONTANA STATE UNIVERSITY

    BOZEMAN, MONTANAPHONE: 406.994.5413

    FAX: 406.994.5665

    Consultant #:1710

    CL

    ASS

    RO

    OM

    RE

    NO

    VA

    TIO

    NS

    2018

    REI

    D H

    ALL

    45

    2 1

    00

    % C

    ON

    STR

    UC

    TIO

    N D

    RA

    WIN

    GS

    MOSAICDRA

    GENERAL & CODEINFORMATION

    A00103/19/2018

    PR

    OJE

    CT

    # 1

    PPA#18-2011

    1/4" = 1'-0" REF: 1/ A200REID 452 CODE PLAN4

    0' 2' 4' 8' 16'

  • WAP

    A B

    2

    1

    C

    3

    1.

    2.

    3.

    4.

    6.

    3.

    5.7.

    7.

    7.

    7.

    7.

    7.

    DEMO LEGEND

    DEMOLISHED

    EXISTING WALL TO REMAIN

    A. PATCH AND PREP ALL WALLS FOR PAINT UNLESS OTHERWISE INDICATED.B. VERIFY ALL CONDITIONS AND COORDINATE WITH ALL DISCIPLINES OF CONTRACT.

    UNDOCUMENTED FIELD CHANGES MAY HAVE OCCURRED AND ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT WHEN DISCOVERED.

    C. WHERE DEMOLITION IS INDICATED, WALLS SHALL BE REMOVED AND CEILING SHALL BE PATCHED, REPAIRED AND PAINTED TO MATCH EXISTING.

    D. UNLESS DEMOLITION IS INDICATED, PATCH AND PROTECT EXISTING CEILING.E. COORDINATE ALL MECHANICAL, ELECTRICAL, FIRE SYSTEMS, COMMUNICATIONS AND UTILITY

    SHUT-DOWNS WITH OWNER PRIOR TO REMOVING AND OR RELOCATING, PER MSU REQUIREMENTS.

    F. ALL DEMOLITION DRAWINGS ARE INTENDED TO SHOW GENERAL SCOPE OF WORK WITHIN THE INTENT OF THE PROJECT AND ARE NOT INTENDED TO EXCLUDE ANY DEMOLITION WORK NECESSARY FOR PRIOR COMPLETION OF THE WORK OUTLINED IN THE PROJECT DOCUMENTS. CONTRACTOR SHOULD ASSUME ADDITIONAL MINOR DEMOLITION ITEMS NOT SHOWN ON PLANS, NO ADDITIONAL PAYMENT WILL BE MADE FOR SUCH MINOR ELEMENTS.

    G. THESE DRAWINGS INDICATE STRUCTURAL AND NON-STRUCTURAL DEMOLITION THAT IS TO OCCUR TO MAKE WAY FOR NEW CONSTRUCTION. ADDITIONAL STRUCTURAL DEMOLITION WORK, CONSTRUCTION OR SHORING REQUIRING COORDINATION WITH NEW STRUCTURAL INS INDICATED ON THE STRUCTURAL DRAWINGS.

    H. SEE MECH. AND ELEC. DEMOLITION PLANS FOR SPECIFIC DEMO OF MECHANICAL AND ELECTRICAL SYSTEMS.

    I. SEE HAZARDOUS MATERIALS ABATEMENT REPORT FOR ADDITIONAL INFORMATION AND COORDINATION.

    GENERAL DEMOLITION NOTES:

    A B

    2

    1

    C

    3

    9.

    8.

    8.

    10.

    11.

    11.

    11.

    11.

    72

    0 S

    . Tr

    acy

    Ave

    ., B

    ozem

    an, M

    T

    dRA-

    Arc

    hite

    ct.c

    om

    dRA

    den

    nis

    Raf

    fens

    perg

    erArc

    hite

    ct

    REV. DESCRIPTION DATE

    REVIEWED BY:DRAWN BY:

    SHEET

    DATE

    SHEET TITLE

    MO

    NT

    AN

    AST

    AT

    E U

    NIV

    ER

    SIT

    Y

    MSU-CPDCMONTANA STATE UNIVERSITY

    BOZEMAN, MONTANAPHONE: 406.994.5413

    FAX: 406.994.5665

    Consultant #:1710

    CL

    ASS

    RO

    OM

    RE

    NO

    VA

    TIO

    NS

    2018

    REI

    D H

    ALL

    45

    2 1

    00

    % C

    ON

    STR

    UC

    TIO

    N D

    RA

    WIN

    GS

    AuthorChecker

    DEMO PLANS

    A10003/19/2018

    PR

    OJE

    CT

    # 1

    PPA#18-2011

    1/4" = 1'-0" REF: 1/ A200REID 452 DEMO PLAN1

    DEMOLITION NOTES1. REMOVE WALL. SEE HAZARDOUS MATERIALS REPORT

    2. REMOVE WALL AND DOOR. SEE HAZARDOUS MATERIALS REPORT

    3. REMOVE WHITEBOARDS. SALVAGE ANY WHITEBOARDS IN GOOD CONDITION AFTER REMOVAL; SEEHAZARDOUS MATERIALS REPORT

    4. REMOVE CARPET & BASE

    5. REMOVE TILE; PREP FLOOR FOR CARPET. SEE HAZARDOUS MATERIALS REPORT

    6. PREP WINDOW SILL FOR PAINT

    7. REMOVE WINDOW SHADE

    8. PATCH AND PROTECT EXISTING CEILING TILE. PREP FOR PAINT. IF DAMAGED DURING WALL DEMOREMOVE EXISTING CEILING TILES FOR NEW GYP AND PAINT. REFER TO HAZARDOUS MATERIALSREPORT

    9. PATCH AND PROTECT EXISTING CEILING TILE. PREP FOR PAINT.

    10. DEMO CEILING FOR NEW MECHANICAL EQUIPMENT. LIMIT OPENING TO SIZE OF GRILL. SEE MEP

    11. REMOVE LIGHT FIXTURE. PATCH CEILING WITH GYPSUM & CEILING TILES TO MATCH EXST. PREP FORPAINT.

    1/4" = 1'-0" REF: 1/ A200REID 452 RCP DEMO3

  • A B

    2

    1

    C

    3

    A200

    1

    4

    3

    2

    P6

    P6

    1'-6

    "

    4'-0"

    WINDOW SILL TO BE PAINTED P1

    IN-CARPET TRACK FOR UMBILICAL. LOCATION TO BE FIELD VERIFIED

    5'-1

    1 1/

    4"

    3'-2 1/4"

    968 SF

    REID

    452

    NEW SHADE AT WINDOW

    NEW SHADE AT WINDOW

    NEW SHADE AT WINDOW

    PODIUM NIC. FOR REFERENCE ONLY

    WALL BELOW WINDOW & COLUMN BETWEEN WINDOWS TO BE PAINTED P1

    P1

    P1

    NEW DOOR. SEE SPEC

    A101

    4

    3

    A101Sim

    48" ST. STL. CORNER GUARD

    48" ST. STL. CORNER GUARD

    A200

    8

    Sim

    6

    A200Sim

    A B

    2

    1

    C

    3

    15'-0"

    PROJECTOR INSTALL:PROJECTOR NIC. GC TO RELOCATE EXST PROJECTOR POLE AND MOUNT. GC TO INSTALL APPROPRIATE BACKING/SUPPORT. FINAL LOCATION TO BE FIELD VERIFIED.

    PROJECTION SCREEN INSTALL:GC TO PURCHASE AND INSTALL SCREEN AND APPROPRIATE MOUNTING HARDWARE. GC TO INSTALL APPROPRIATE BACKING/SUPPORT. FINAL LOCATION TO BE FIELD VERIFIED.

    12'-7 3/8"

    2'-0

    "2'

    -0"

    EXST.8'-4"

    CT-18'-2 7/8"

    10'-0

    "

    4'-0" 4'-0"

    4'-0"10'-0

    "

    5'-0

    "

    4'-0" 4'-0" 4'-0"

    10'-0

    "

    10'-0

    "

    5'-0

    "

    ACOUSTIC PANEL LAYOUT TYP.: EVENLY SPACE BETWEEN LIGHTS WITHOUT OBSTRUCTING MEP. ALIGN PANEL EDGES.

    GYP8'-4"

    5

    A101

    PATCH CEILING WITH GYPSUM BOARD; COVER WITH ACOUSTIC CEILING TILES TO MATCH EXST.

    EXST WOODEN PANEL - PAINT TO MATCH CEILING, TYP. @ ALL WODEN PANELS

    ROOM FINISH LEGENDFLOOR FINISHES:

    BASE FINISHES:

    PAINTED GWB: PAINT COLOR OVER GYPSUM BOARD - TYP. U.N.O.. COLOR AS INDICATED.

    PAINT COLOR SELECTIONS:P1- OFF WHITE. SHERWIN WILLIAMS "CREAMY" SW-7012. LRV 83P2- ACCENT COLOR: BLUE. SHERWIN WILLIAMS "SANTORINI BLUE" SW-7607. LRV 14

    WALL FINISHES: CEILING FINISHES:

    CARPET-CP1

    FLOOR FINISH NOTES:1. IF FINISHES ARE NOT CLEARLY INDICATED FOR AN AREA, CLARIFY INTENT WITH

    ARCHITECT.2. PROVIDE APPROPRIATE TRANSITION TRIM AT ALL MATERIAL CHANGES.3. TEST ALL SUBSTRATES TO VERIFY COMPLIANCE WITH FINISH MANUFACTURE'S

    SPECIFICATIONS PRIOR TO FLOORING INSTALLATION.4. PATCH, REPAIR, AND/OR GRIND ALL SUBSTRATES TO ACCEPTABLE LEVEL OF

    SMOOTHNESS/LEVELNESS PRIOR TO FLOORING INSTALLATION.5. FLOORING CHANGE FROM ROOM TO HALLWAY TO OCCUR AT END OF VESTIBULE.6. SAMPLES FOR ALL FINISHES MUST BE SUBMITTED TO AND APPROVED BY ARCHITECT

    PRIOR TO ORDERING.

    SEE ROOM FINISH SCHEDULE FOR LISTING OF MATERIALS .

    WALL FINISH NOTES:1. SEE INTERIOR ELEVATIONS FOR INTERIOR WINDOWS, SPECIAL WALL FINISHES, TRIM, ETC.2. IF FINISHES ARE NOT CLEARLY INDICATED FOR AN AREA, CLARIFY INTENT WITH ARCHITECT.3. PROVIDE APPROPRIATE TRANSITION TRIM AT ALL MATERIAL CHANGES.4. PROVIDE CLEAN, CONSISTENT CAULK JOINTS AT ABUTMENTS OF DISSIMILAR MATERIALS.5. PROVIDE METAL EDGING AT ALL GYPSUM BOARD EDGES THAT ABUT DISSIMILAR

    MATERIALS.

    DOOR & DOOR FRAME FINISHES:1. ALL METAL DOORS AND DOOR FRAMES TO RECEIVE PAINT FINISH AS SPECIFIED.

    COLOR SELECTIONS:INTERIOR PAINTED DOORS: WOOD TO MATCH EXST HALLWAY DOORSINTERIOR PAINTED DOOR FRAMES: WHITE

    CORNER TRIMS:

    CORNER TRIM, 26 GA. PREFIN. METAL CORNER TRIM WITH 2" WINGS, LENGTH AS INDICATED ON PLANS OR ELEVATIONS.

    C.T.

    CHAIR RAIL: CORIAN SOLID SURFACE - TYP. U.N.O. COLOR AS INDICATED.

    CORIAN COLOR SELECTIONS:CR5 - DEEP MINK

    CHAIR RAIL NOTES:1. FIELD LAYOUT ALL CHAIR RAIL LENGTHS2. CHAIR RAIL TO WRAP COLUMNS AS SHOWN IN INTERIOR ELEVATIONS.

    CHAIR RAIL:

    EXST. 1 EXISTING CEILING TILE: TO BE PREPPED AND PAINTED, SEE SPECIFICATION

    GYP. GYPSUM CEILING: GYPSUM TO BE APPLIED DIRECTLY TO EXISTING PLASTER CEILING IF EXISTING CEILING TILE IS DAMAGED DURING DEMOLITION. PAINT TO MATCH EXISTING CEILING TILE

    CT-1

    CARPET TILE- CP1: 25CM X 1 M CARPET TILE. INSTALLATION METHOD: ASHLAR; VARY LOCATION OF ACCENT COLOR TO GET RANDOM PATTERN EFFECT

    CARPET COLOR: BROWN MARBLE WITH BLUE & YELLOW LINEAR ACCENT COLORS

    RUBBER BASE: BLACK BROWN COLOR, 3.2 MM THICK, 4" HIGH

    TRANSITION STRIP: SOLID VINYL REDUCER STRIP; GRAPHITE GRAY COLOR.

    CT-1 CEILING TREATMENT: ACOUSTIC CEILING PANELS TO BE ATTACHED TO EXISTING CEILING TILE.

    PANEL FABRIC DESCRIPTION: LINE - SURF 2941, COLOR - SANTA CRUZ 9020

    PIPE & RADIATOR FINISHES:

    RADIATOR FINISH: TO BE PREPPED & PAINTED WHITE, SEE SPECIFICATION

    PIPE FINISH: N/A

    DRYWALL J MOLDING

    5/8" TYPE X GWB PAINTED

    3 5/8" MTL STUD FRAMING

    DRYWALL J MOLDING

    5/8" TYPE X GWB PAINTED

    4" RUBBER BASE

    CARPET

    EXST FLOOR

    3 5/8" MTL STUD FRAMING

    ATTACH FRAMING TO EXST FLOOR. SET IN ACOUSTIC SEALANT, CONTIN.

    ATTACH FRAMING TO EXST CEILING

    EXST CEILING

    5/8" TYPE X GWB PAINTED

    5/8" TYPE X GWB PAINTED

    4" RUBBER BASE

    CARPET

    ACOUSTIC SEALANT, CONTIN.

    DRYWALL J MOLDING

    ACOUSTIC BATT INSUL., TYP.

    A

    EXISTING WALL

    5/8" TYPE X GWB

    3 5/8" MTL STUD FRAMING

    5/8" TYPE X GWB

    EXTEND GWB TO COVER EXST WALL END

    48" ST. STL CORNER GUARD

    ACOUSTIC BATT INSUL., TYP.

    CORNER BEAD, TAPED & PTD.

    EXST CLG SUSPENDED SYSTEM

    EXST PLASTER CLG

    EXST TILES TO REMAIN & PAINTED

    CLIP ATTACHED TO EXST CEILING PER MANF RECMD

    CLIP PRE-ATTACHED TO ACOUSTIC PANEL

    ADHESIVE PER MANF RECMD

    ACOUSTIC PANEL:SEE SPECIFICATION SECTION 098550

    1 1/

    8"

    72

    0 S

    . Tr

    acy

    Ave

    ., B

    ozem

    an, M

    T

    dRA-

    Arc

    hite

    ct.c

    om

    dRA

    den

    nis

    Raf

    fens

    perg

    erArc

    hite

    ct

    REV. DESCRIPTION DATE

    REVIEWED BY:DRAWN BY:

    SHEET

    DATE

    SHEET TITLE

    MO

    NT

    AN

    AST

    AT

    E U

    NIV

    ER

    SIT

    Y

    MSU-CPDCMONTANA STATE UNIVERSITY

    BOZEMAN, MONTANAPHONE: 406.994.5413

    FAX: 406.994.5665

    Consultant #:1710

    CL

    ASS

    RO

    OM

    RE

    NO

    VA

    TIO

    NS

    2018

    REI

    D H

    ALL

    45

    2 1

    00

    % C

    ON

    STR

    UC

    TIO

    N D

    RA

    WIN

    GS

    AuthorChecker

    FLOOR PLAN &REFLECTED CEILING

    PLAN & DETAILS

    A10103/19/2018

    PR

    OJE

    CT

    # 1

    PPA#18-2011

    1/4" = 1'-0" REF: 1/ A200REID 452 PLAN1 1/4" = 1'-0" REF: 1/ A200

    REID 452 RCP2

    1 1/2" = 1'-0" REF: 1/ A101WALL SECTION DETAIL3 1 1/2" = 1'-0" REF: 1/ A101

    PLAN DETAIL @ NEW WALL4

    3" = 1'-0" REF: 2/ A101CEILING DETAIL @ ACOUSTIC PANEL5

  • LEVEL 1100'-0"

    P6

    P6

    WB411'-10"

    RUBBER BASE

    CR5

    P6P1

    3'-0

    "

    10"

    P6

    CHAIR RAIL END @ VERTICAL WIREMOLD

    4'-5"

    P6

    LEVEL 1100'-0"

    P1

    WB5

    P1

    8'-4 1/4"

    RUBBER BASE

    2 3/4"

    PROJECTION SCREEN INSTALL:FINAL LOCATION TO BE FIELD VERIFIED.VERIFY WALL TYPE AND PROVIDE APPROPRIATE ANCHOR FOR MOUNTING.

    3'-0

    "

    NEW DOOR. SEE SPEC

    LEVEL 1100'-0"

    P1

    WB4 P6

    8'-6"

    6'-4"

    CR5

    RUBBER BASE

    3'-0

    "

    10"

    LEVEL 1100'-0"

    WINDOW SILL TO BE PAINTED P-1

    P1EXST RADIATOR - PAINT WHITE EXST RADIATOR - PAINT WHITE EXST RADIATOR - PAINT WHITE

    P1P1 WINDOW SILL TO BE PAINTED P-1

    RUBBER BASE

    P1

    TOP OF RACEWAY @ BOTTOM OF WINDOW SILL.

    NEW SHADE, SEE SPECNEW SHADE, SEE SPECNEW SHADE, SEE SPEC NEW SHADE, SEE SPEC NEW SHADE, SEE SPEC NEW SHADE, SEE SPEC

    1" TACK STRIP

    8'-0"

    4'-0

    "

    WB1

    MARKER TRAY

    1" TACK STRIP

    10'-0"

    4'-0

    "

    WB2

    MARKER TRAY

    1" TACK STRIP

    12'-0"

    4'-0

    "

    WB3

    MARKER TRAY

    1" TACK STRIP

    16'-0"

    4'-0

    "

    WB4

    MARKER TRAY

    1" TACK STRIP

    20'-0"

    4'-0

    "

    WB5

    MARKER TRAY

    NOTE: MOUNTING HEIGHT - BOTTOM OF WHITEBOARD IS TO BE 3' AFFWHITE BOARD TYPESSEE PLAN AND ELEVATIONS FOR LOCATIONS

    10"

    3/4" SOLID SURFACE MATERIAL W/ 45 DEGREE MITER JOINT @ TOP CORNER

    3/4" PLYWD. CLEAT, GLUED TO SOLID SURF. MTL

    SET CLEAT IN CONST. ADHESIVE

    EXST WALL

    CONTIN. SEALANT JT., COLOR MATCH TO SOLID SURF. MTL.

    3/4" PLYWD. CLEAT SCREWED TO WALL

    LEGRAND STEEL WIREMOLD V700 SERIES, OR EQ.

    HUBBELL HBL5715BR TEE FITTING BEND RADIUS, OR EQ.

    HUBBELL HBL5748 STANDARD I-GANG BOX, OR EQ., W/DUAL OUTLET

    10"

    3/4" SOLID SURFACE MATERIAL W/ 45 DEGREE MITER JOINT @ TOP CORNER

    SET CLEAT IN CONST. ADHESIVE

    EXST WALL

    CONTIN. SEALANT JT., COLOR MATCH TO SOLID SURF. MTL.

    3/4" PLYWD. CLEAT SCREWED TO WALL

    LEGRAND STEEL WIREMOLD 3000 SERIES, OR EQ., CONTIN.

    3/4" PLYWD. CLEAT, GLUED TO SOLID SURF. MTL

    VERTICAL WIREMOLD

    IN-CARPET TRACK FOR PODIUM UMBILICAL BELOW, SEE PLAN FOR LOCATION

    WALL

    SOLID SURFACE MTL

    MITER CORNER, CONT SOLID SURFACE TO WALL FACE. TYP. @ ALL ENDS OF CHAIR RAIL

    CHAIR RAIL DISTANCE TO VERTICAL WIREMOLD, SEE ELEVATION DWG

    72

    0 S

    . Tr

    acy

    Ave

    ., B

    ozem

    an, M

    T

    dRA-

    Arc

    hite

    ct.c

    om

    dRA

    den

    nis

    Raf

    fens

    perg

    erArc

    hite

    ct

    REV. DESCRIPTION DATE

    REVIEWED BY:DRAWN BY:

    SHEET

    DATE

    SHEET TITLE

    MO

    NT

    AN

    AST

    AT

    E U

    NIV

    ER

    SIT

    Y

    MSU-CPDCMONTANA STATE UNIVERSITY

    BOZEMAN, MONTANAPHONE: 406.994.5413

    FAX: 406.994.5665

    Consultant #:1710

    CL

    ASS

    RO

    OM

    RE

    NO

    VA

    TIO

    NS

    2018

    REI

    D H

    ALL

    45

    2 1

    00

    % C

    ON

    STR

    UC

    TIO

    N D

    RA

    WIN

    GS

    AuthorChecker

    ELEVATIONS

    A20003/19/2018

    PR

    OJE

    CT

    # 1

    PPA#18-2011

    3/8" = 1'-0" REF: 1/ A101REID 452 SOUTH ELEVATION1 3/8" = 1'-0" REF: 1/ A101

    REID 452 WEST ELEVATION2

    3/8" = 1'-0" REF: 1/ A101REID 452 NORTH ELEVATION3 3/8" = 1'-0" REF: 1/ A101

    REID 452 EAST ELEVATION4

    1" = 1'-0" REF: 1/ A101CHAIR RAIL DETAIL6 1" = 1'-0"

    RACEWAY ALTERNATE CHAIR RAIL DETAIL7

    1" = 1'-0" REF: 1/ A101PLAN DETAIL - CHAIR RAIL @ VERTICAL WIREMOLD8

  • T

    A.) IT SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR TO FIELD COORDINATE THE LOCATION OF EQUIPMENT ROUTING OF ALL DUCTWORK AND PIPING WITH ALL OTHER TRADES.

    B.) IT SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR TO REVIEW THE DRAWINGS FOR ALL DICIPLINES AND PROVIDE ALL LABOR AND MATERIALS REQUIRED FOR A COMPLETE INSTALLATION.

    C.) COORDAINTE THE INSTALLATION OF GRILLES, REGISTERS AND DIFFUSERS WITH THE ARCHITECTURAL REFLECTED CEILING PLANS AND THE ELECTRICAL LIGHTING PLANS.

    D.) VERIFY THE LOCATION OF THERMOSTATS AND SENSORS WITH THE ARCHITECT AND ENGINEER PRIOR TO INSTALLATION. INSTALL THERMOSTATS 48" ABOVE FINISHED FLOOR PER ADA REQUIREMENTS.

    E.) PROVIDE AND INSTALL SEISMIC BRACING FOR ALL EQUIPMENT, DUCTWORK AND PIPING PER THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE.

    F.) FLEXIBLE DUCTWORK BETWEEN BRANCH DUCTS AND GRILLES, REGISTERS OR DIFFUSERS SHALL BE LIMITED TO 5FT.

    G.) PROVIDE AND INSTALL FIRE, SMOKE AND/OR COMBINATION SMOKE/FIRE DAMPERS WHERE DUCTWORK PASSES THROUGH FIRE RATED ASSEMBLIES. ASSOCAITED DUCTDETECTORS SHALL BE ADRESSABLE. SMOKE DAMPERS AND COMBINATION SMOKE/FIRE DAMPERS SHALL INCLUDE A KEYED REMOTE TEST SWITCH LOCATED IN AN ACCESSIBLE LOCATION. FIELD COORDINATE THE LOCATION OF TEST SWITCHES WITH THE ARCHITECT AND ENGINEER PRIOR INSTALLATION.

    H.) SEAL ALL DUCT AND PIPE PENETRATIONS THROUGH FIRE RATED ASSEMBLIES WITH A UL-APPROVED FIRE STOP SYSTEM.

    I.) PROVIDE ACCESS DOORS TO ALLOW SERVICE AND INSPECTION OF EQUIPMENT, VALVES, DAMPERS AND DEVICES INSTALLED ABOVE NON-REMOVABLE CEILINGS.

    J.) PROVIDE REMOTE CONTROLLED DAMPER ACTUATORS FOR BALANCING DAMPERS INSTALLED IN INACCESIBLE LOCATION. PROVIDE RUSKIN ZPD25 OR APPROVED EQUAL.

    GENERAL MECHANICAL NOTESKEY NOTES:#A B C

    1

    2

    3

    1

    (TYP)1

    (TYP)

    R-1

    2

    2

    2

    3

    24"x12"

    R-1

    24"x12"

    MATTHEW W.

    CARR

    No. 20181 PE

    MONTA NA

    L IC E NS ED

    PR

    OF

    ESS IONA L ENG

    INE

    ER

    REV. DESCRIPTION DATE

    REVIEWED BY:

    DRAWN BY:

    SHEET

    DATE

    SHEET TITLE

    MO

    NT

    AN

    AS

    TA

    TE

    UN

    IV

    ER

    SIT

    Y

    MSU-CPDCMONTANA STATE UNIVERSITY

    BOZEMAN, MONTANA

    PHONE: 406.994.5413

    FAX: 406.994.5665

    6159.001

    CL

    AS

    SR

    OO

    MR

    EN

    OV

    AT

    ION

    S 2

    018

    RE

    ID H

    AL

    L 4

    52

    10

    0%

    CO

    NS

    TR

    UC

    TIO

    N D

    RA

    WIN

    GS

    MWCECR

    MECHANICAL PLAN &

    SCHEDULE

    M100

    03/19/2018

    PR

    OJE

    CT

    #1

    PPA#18-2011

    3/8" = 1'-0"1MECHANICAL PLAN

    NOTES: PROVIDE MANUAL BALANCING DAMPER AT LOCATIONS WHERE A SPECIFIED AIR VOLUME IS REQUIRED I.E. FOR SUPPLY AND EXHAUST ONLY. COORDINATE FRAME AND MOUNTING TYPE WITH CEILING TYPES. SEE ARCHITECTURAL PLANS FOR CEILING TYPES. THE CONTRACTOR SHALL BERESPONSIBLE TO PROVIDE ALL FITTINGS AND ACCESSORIES REQUIRED FOR A COMPLETE INSTALLATION. SCHEDULES N.C. VALUES ARE VALID FOR SCHEDULE AIR FLOW ONLY AND REPRESENT A MAXIMUM ACCEPTABLE N.C. VALUE. SUBSTITUTED EQUIPTMENT SHALL HAVE N.C. VALUE EQUAL TO OR BELOWTHE SCHEDULES N.C. AT THE AIR FLOW LISTED ON THE PLANS.

    R-1 KRUEGER S80P PERFORATED RETURN GRILLE WITH 24"x24" SURFACE MOUNTING... RETURN 1125 20 - - 0.04 22"x22" N/A STEEL BY ARCH SEE NOTES

    MARK MFGR MODEL DESCRIPTION FUNCTION MAX CFMNC AT MAX

    CFMTHROW AT MAX

    CFM (FT)PRESSURE DROP AT MAX CFM

    (in. W.C.)NECK SIZE

    (W"xH")DAMPER TYPE MATERIAL FINISH REMARKS

    GRILLE, REGISTER AND DIFFUSER SCHEDULE

    1. EXISTING MIXING BOX DIFFUSERS TO REMAIN IN PLACE. CONTRACTOR SHALL CLEAN DIFFUSERS FACE.

    2. EXISTING CABINET CONVECTORS TO REMAIN.

    3. TRANSFER DUCT SHALL BE BE ACOUSTICALLY LINED. SEE SPECIFICATIONS FOR DETAILS.

  • X

    D-1

    X X

    X X

    J

    TV

    X

    X

    X

    OS

    P

    R1

    R2

    R3

    R4

    LV

    F F

    F

    S S

    S S

    BRANCH CIRCUIT PANELBOARD

    PANEL AND CIRCUIT DESIGNATION ARE SHOWN NEXT TOEACH DEVICE (PANEL NAME - CIRCUIT NUMBER). BRANCHCIRCUIT WIRE SIZE IS #12 UNLESS NOTED OTHERWISE. ASINGLE INSULATED GREEN GROUND CONDUCTOR SHALL BEPROVIDED WITH EACH HOME RUN. PROVIDE A SEPARATENEUTRAL FOR EACH CIRCUIT. HOME RUNS SHALL HAVE NOMORE THAN THREE CIRCUITS. LINE VOLTAGE AND LOWVOLTAGE WIRING IS NOT SHOWN ON PLANS. FOR EQUIPMENTCIRCUITING, SEE MEP COORDINATION SCHEDULE.

    DUPLEX, 4PLEX RECEPTACLE. (MOUNT AT +18" AFF. UNO.)X-GFI-GFCI RECEPTACLEWP-WEATHER PROOF WITH WHILE IN USE COVER

    DUPLEX, 4PLEX ABOVE COUNTER RECEPTACLE MOUNTED 4"ABOVE BACKSPLASH

    FLOOR OUTLET - HUBBELL MODEL #HBLCFB401CB, COVERMODEL #HBLTCGNTBKSW, OR EQUAL.

    FLOOR BOX WITH COMBINATION 4PLEX RECEPTACLE & 2TELEPHONE/DATA OUTLETS- HUBBELL MODEL#HBLCFB401CB, COVER MODEL #HBLTCGNTBKSW, OR EQUAL.

    JUNCTION BOX

    COMBO POWER/DATA DIVIDED TV BOX; 2-GANG, LEGRAND2444D-2NFW, OR EQUAL. DUPLEX RECEPTACLE & SINGLEGANG DATA PORT W/ FACEPLATES. SEE ARCHITECTURALFOR MOUNTING HEIGHT.

    SPECIAL PURPOSE OUTLET, MOUNT AT +18" AFF. UNO.LETTER INDICATES TYPE:TYPE A: NEMA 5-20R, TYPE B: NEMA 5-30R,TYPE C: NEMA 5-50R, TYPE D: NEMA 6-20R,TYPE E: NEMA 6-30R, TYPE F: NEMA 6-50RTYPE G: NEMA 14-20R, TYPE H: NEMA 14-30RTYPE I: NEMA 14-50R

    PUSHBUTTON (MOUNT AT +54" AFF, UNO.). "X" DENOTES TYPE:"EPO" = EMERGENCY POWER OFF"ADA" = HANDICAP ACCESSIBLE DOOR (DEVICE BY OTHERS)"ODO" = OVERHEAD DOOR OPERATOR (DEVICE BY OTHERS)

    SURFACE MOUNTED RACEWAY: SEE PLANS & SPECS.

    RACEWAY STUB-OUT OR STUB-UP WITH CAPPED END

    RACEWAY STUB-OUT OR STUB-UP WITH BUSHED END

    ELECTRICAL POWER LEGEND

    STANDARD LIGHTING CONTROLS:SWITCHES AND LINE VOLTAGE DIMMERS

    TOGGLE SWITCH (MOUNT AT 46" AFF. UNO.)

    SUBSCRIPTS:

    NO SUBSCRIPT INDICATES SINGLE POLE

    "3" INDICATES THREE-WAY

    "4" INDICATES FOUR-WAY

    "D" INDICATES DIMMER SWITCH - PHILIPS SUNRISE - ON/OFF

    "K" INDICATES KEYED SWITCH

    "T" INDICATES TIMER

    "P" INDICATES PILOT LIGHT

    "OS" INDICATES WALL SWITCH OCC SENSOR-

    - WATTSTOPPER DW100 (SINGLE OR DUAL DW-200 SWITCH).

    "OSD" INDICATES WALL SWITCH OCC SENSOR w/ 0-10V DIMMING

    - WATTSTOPPER W-311

    "a" INDICATES SINGLE POLE LIGHTING SWITCH FOR ZONE a

    "b" INDICATES SINGLE POLE LIGHTING SWITCH FOR ZONE b

    "ab" INDICATES LIGHTING SWITCHES w/ MULTIPLE ZONES

    DIGITAL LIGHTING CONTROLS:ROOM CONTROLLERS AND LOW VOLTAGE DEVICES

    DIGITAL OCCUPANCY SENSOR - CEILING MOUNT.WATTSTOPPER LMDC-100 OR EQUAL

    DIGITAL PHOTOCELL - CEILING MOUNT. WATTSTOPPERLMLS-400 OR EQUAL

    ROOM CONTROLLER - WATTSTOPPER DLM LMRC-101 OR EQUAL.

    ROOM CONTROLLER - WATTSTOPPER DLM LMRC-102 OR EQUAL.

    ROOM CONTROLLER - WATTSTOPPER DLM LMRC-212 OR EQUAL.

    ROOM CONTROLLER - WATTSTOPPER DLM LMRC-213 OR EQUAL.

    LOW VOLTAGE SWITCH - WATTSTOPPER LMSW-10X, "X"DENOTES NUMBER OF BUTTONS. SEE LIGHTING CONTROLDIAGRAM ON THIS SHEET.

    ELECTRICAL LIGHTING CONTROL LEGEND

    RECESSED FLUORESCENT FIXTURE- "a" & "b" DESIGNATESSWITCH

    RECESSED EMERGENCY FLUORESCENT FIXTURE- "a"& "b"DESIGNATES SWITCH

    SURFACE OR PENDANT FLUORESCENT FIXTURE- "x"DESIGNATES SWITCH LEG

    SURFACE OR PENDANT EMERGENCY FLUORESCENT FIXTURE-"x" DESIGNATES SWITCH LEG

    1X4 SURFACE WALL MOUNT FLUORESCENT

    FLUORESCENT STRIP OR INDUSTRIAL, SURFACE OR CHAINHUNG

    POLE MOUNTED FIXTURE

    LIGHTED BOLLARD

    PENDANT FIXTURE; HIGH BAY, LOW BAY, DECORATIVE

    EXIT SIGN - WALL MOUNT, CEILING MOUNT. ARROWINDICATES DIRECTION OF TRAVEL, SHADING INDICATESLIGHTED FACE.

    EMERGENCY EGRESS BATTERY PACK, WALL MOUNT ORCEILING MOUNT

    WALL MOUNTED SCONCE OR WALLPACK FIXTURE

    SURFACE MOUNTED DOWNLIGHT

    RECESSED CAN DOWNLIGHT

    RECESSED CAN WALLWASHER

    TRACK LIGHTING. SEE FIXTURE SCHEDULE AND LIGHTINGPLANS.

    ELECTRICAL LIGHTING FIXTURE LEGENDTELEPHONE OUTLET

    VOICE-DATA OUTLET. PROVIDE PATHWAY TO ACCESSIBLE CEILING

    SPACE AS SHOWN ON PLANS. CABLING BY MSU IT.

    DATA OUTLET

    WIRELESS ACCESS POINT, COORDINATE WITH MSU IT.

    STROBE WALL MOUNT (MOUNT AT +82" AFF, UNO.) AND CEILINGMOUNT

    FIRE ALARM MANUAL STATION (MOUNT AT +46" AFF, UNO.)

    HORN/STROBE WALL MOUNT (MOUNT AT +82" AFF, UNO.) ANDCEILING MOUNT

    SPEAKER STROBE WALL MOUNT (MOUNT AT +82" AFF, UNO.) ANDCEILING MOUNT

    SPEAKER, COORDINATE WITH MSU IT.

    ELECTRICAL SYSTEM LEGEND

    WAP

    ELECTRICAL PROJECT NOTESA. PRIOR TO BID CONTRACTOR SHALL VISIT THE SITE. NOT ALL WORK

    REQUIRED TO COMPLETE THE PROJECT IS SHOWN ON THE DRAWINGS. THECONTRACTOR SHALL BECOME THOROUGHLY FAMILIAR WITH ALL THE WORKREQUIRED TO COMPLETE THE PROJECT IN ADDITION TO THE LOCALCONDITIONS AND INCLUDE SAID WORK IN THE BID.

    B. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OFALL ELECTRICAL SERVICE WORK WITH UTILITY. OWNER PAYS ALL FEES,CONTRACTOR DOES ALL SCHEDULING AND COORDINATION OF WORK. IT ISTHE SOLE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE ALLSCHEDULES ARE MET.

    C. GENERAL WORK PRACTICES FOR ELECTRICAL CONSTRUCTION SHALL BEIN ACCORDANCE WITH NECA 1, "STANDARD PRACTICES FOR GOODWORKMANSHIP IN ELECTRICAL CONTRACTING." THIS PUBLICATION ISAVAILABLE FROM NECA BY TELEPHONE AT 301-657-3110 OR ON-LINE ATWWW.NECANET.ORG.

    D. IT IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE WITHMECHANICAL FOR PLENUM SPACES AND PROVIDE PLENUM RATED CABLESWHERE REQUIRED FOR LIGHTING CONTROL, DATA, FIRE ALARM AND ALLOTHER L.V. SYSTEMS NOT INSTALLED IN CONDUIT. VERIFY CONDUITREQUIREMENTS ON DRAWINGS AND SPECIFICATIONS.

    E. FIRE-RESISTANCE: PROVIDE A MINIMUM HORIZONTAL DISTANCE OF 24"BETWEEN OUTLET BOXES LOCATED ON OPPOSITE SIDES OFFIRE-RESISTANCE RATED WALLS. WHERE THIS IS NOT POSSIBLE INSTALL ULLISTED PUTTY PADS ON ALL OUTLET BOXES NOT MEETING THE 24"SEPARATION. PROVIDE A UL LISTED THROUGH -PENETRATION FIRESTOPFOR PENETRATIONS OF FIRE-RESISTANCE RATED ASSEMBLIES.

    F. CONDUCTORS ARE SIZED PER THE 75 DEGREE C RATING COLUMN OF NECTABLE 310.16. IF THE TERMINAL USED FOR A TERMINATION OF A PARTICULARCONDUCTOR IS NOT MARKED, OR THE TERMINAL IS MARKED FOR 60 DEGREEC CONDUCTORS, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TOEITHER ADJUST THE AMPACITY OF THE CONDUCTOR TO MATCH THE 60DEGREE COLUMN OF TABLE 310.16, OR REPLACE THE TERMINAL WITH ONERATED FOR AT LEAST 75 DEGREES C

    G. FOR 20A BRANCH CIRCUIT RUNS EXTENDING BEYOND 300 LINEAR FEET.CONDUCTOR SIZE SHALL BE A MINIMUM OF #10 CU.

    H. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V BRANCHCIRCUIT.

    I. DURING DEMOLITION, THE CONTRACTOR SHALL NOTE ALL EXISTINGRACEWAY (BOTH SURFACE AND CONCEALED) TO THE EXTENT POSSIBLE.THESE RACEWAYS SHALL BE REUSED TO THE GREATEST EXTENT POSSIBLETO INSURE A CLEAN FINISHED PRODUCT. WHERE PRACTICAL, AND ALLOWEDPER CODE, FISHING THROUGH WALLS WITH MC CABLE IS PREFERRED TOSURFACE-MOUNTED CONDUIT.

    J. CONTRACTOR SHALL REMOVE, TRANSPORT, AND LEGALLY DISPOSE OFLAMPS AND BALLASTS OFF-SITE. IT IS ASSUMED THE THE BALLASTS DO NOTCONTAIN PCBs. THE CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELYIF IT IS SUSPECTED THAT BALLASTS CONTAIN PCBs.

    K. ALL POWER INTERRUPTIONS SHALL BE COORDINATED WITH OWNER. ANYDISRUPTION OF WORKERS IN THE SPACE SHALL BE KEPT TO A MINIMUM ANDBE COORDINATED WITH THE OWNER PRIOR TO WORK COMMENCING IN THATSPACE.

    L. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR OF ANYEXISTING CIRCUITS THAT ARE INTENDED TO REMAIN THAT ARE SAW CUT ORINTERRUPTED AS PART OF THE DEMOLITION PROCESS. PROVISION FOR THISWORK SHALL BE INCLUDED IN THE BID. SUCH CIRCUITS INCLUDE BUT ARENOT LIMITED TO: INTERIOR RECEPTACLE CIRCUITS, INTERIOR LIGHTINGCIRCUITS, EXTERIOR BUILDING LIGHTING, SITE LIGHTING, ETC.

    M. ELECTRICAL DRAWINGS SHOWING EXISTING BUILDING CONDITIONS,SUCH AS DEMOLITION DRAWINGS, EXISTING PANEL SCHEDULES, ETC AREBASED ON RECORD DRAWINGS AND SITE VISITS. IF ACTUAL EXISTINGCONDITIONS DIFFER FROM THOSE SHOWN ON DRAWINGS, PLEASE NOTIFYENGINEER.

    A, AMP AMPERES

    AC ALTERNATING CURRENT

    A/C AIR CONDITIONING

    AF AMP FUSE

    AFF ABOVE FINISHED FLOOR

    AFG ABOVE FINISHED GRADE

    AHU AIR HANDLING UNIT

    AL ALUMINUM

    AS AMP SWITCH

    ATS AUTOMATIC TRANSFER SWITCH

    BAS BUILDING AUTOMATION SYSTEM

    BKR BREAKER

    C RACEWAY/CONDUIT

    CB CIRCUIT BREAKER

    CCTV CLOSED CIRCUIT TELEVISION

    CKT CIRCUIT

    CLG CEILING

    C.O. RACEWAY/CONDUIT ONLY, WITH PULL STRING

    CNTRL CONTROL

    CU COPPER

    DISC DISCONNECT

    DIST DISTRIBUTION

    DPDT DOUBLE POLE DOUBLE THROW

    DWG DRAWING

    EA EACH

    EF EXHAUST FAN

    ELEC ELECTRIC

    EMT ELECTRICAL METALLIC TUBING

    EQUIP EQUIPMENT

    EX, EXIST EXISTING

    FA FIRE ALARM

    FACP FIRE ALARM CONTROL PANEL

    FATC FIRE ALARM TERMINAL CABINET

    FD FUSED DISCONNECT

    FIDS FLIGHT INFORMATION DISPLAY SYSTEM

    FLR FLOOR

    FO FIBER OPTIC

    FVNR FULL VOLTAGE NON-REVERSING

    FVR FULL VOLTAGE REVERSING

    GEC GROUNDED ELECTRODE CONDUCTOR

    GFI GROUND FAULT INTERRUPTER

    GND GROUND

    GRC GALVANIZED RIGID CONDUIT

    HID HIGH INTENSITY DISCHARGE

    HOA HAND-OFF-AUTOMATIC

    HP HORSEPOWER

    HPS HIGH PRESSURE SODIUM

    HTR HEATER

    HVAC HEATING, VENTILATING & AIR CONDITIONING

    HZ HERTZ

    J-BOX JUNCTION BOX

    KVA KILOVOLT AMPERES

    KW KILOWATTS

    LTG LIGHTING

    LPW LUMENS PER WATT

    MAG MAGNETIC STARTER

    MAN MANUAL

    MAX MAXIMUM

    MCC MOTOR CONTROL CENTER

    MDP MAIN DISTRIBUTION PANEL

    MECH MECHANICAL

    MH METAL HALIDE

    MIN MINIMUM

    MSS MOTOR STARTER SWITCH

    N NEUTRAL

    NC NORMALLY CLOSED

    NEC NATIONAL ELECTRICAL CODE

    NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

    NFD NON-FUSED DISCONNECT

    NIC NOT IN CONTRACT

    NO NORMALLY OPEN

    # NUMBER

    OAE OR APPROVED EQUAL

    OC ON CENTER

    OCPD OVERCURRENT PROTECTION DEVICE

    OH OVERHEAD

    P POLE

    PB PUSHBUTTON

    PNL PANEL

    PS POWER SUPPLY

    PVC POLYVINYL CHLORIDE CONDUIT

    PWR POWER

    RECEPT RECEPTACLE

    RCPT RECEPTACLE

    RGS RIGID GALVANIZED STEEL

    RM ROOM

    RVNR REDUCED VOLTAGE NON-REVERSING

    RVR REDUCED VOLTAGE REVERSING

    SP SINGLE POLE TOGGLE SWITCH

    SPEC SPECIFICATION

    SPST SINGLE POLE SINGLE THROW

    SSPB START-STOP PUSHBUTTON

    SW SWITCH

    SWBD SWITCHBOARD

    SWGR SWITCHGEAR

    TB TELEPHONE BOARD

    TC TIME CLOCK

    TD TIME DELAY

    TEL TELEPHONE

    TSP TWISTED SHIELDED PAIR

    TTB TELEPHONE TERMINAL BOARD

    TYP TYPICAL

    UG UNDERGROUND

    UH UNIT HEATER

    UNO UNLESS NOTED OTHERWISE

    UON UNLESS OTHERWISE NOTED

    V VOLT

    VA VOLT AMPERES

    VFD VARIABLE FREQUENCY DRIVE

    W WATTS

    WP WEATHERPROOF

    W/O WITHOUT

    XFMR TRANSFORMER

    Y WYE CONNECTED

    DELTA CONNECTED

    PHASE

    NOTE: THESE ABBREVIATIONS COMPRISE A STANDARD LIST; NOT ALL ABBREVIATIONS APPEAR ON THIS PROJECT.

    ELECTRICAL ABBREVIATIONS LEGEND

    LUMINAIRE SCHEDULETYPE LAMPS DESCRIPTIONS MFR CATALOG NO. OR SERIES MOUNTING/ VOLTAGE LLF (ASSUMED) NOTES

    B1 LED 1'x4' RECESSED EDGE-LIT FLAT PANELPHILIPS

    DAY-BRITE1FXP38L835-4-DS-UNV-DIM RECESSED/ 120-277 0.85 1,2

    NOTES:

    1. SUBMITTED LUMINAIRE REQUIRES PRIOR APPROVAL.

    2. PROVIDE FIRE-RATED DROP-OVER ENCLOSURE OR TENT LUMINAIRE TO MAINTAIN EXISTING FIRE-RATED CEILING ASSEMBLY.

    GENERAL NOTE:

    THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL CEILING TYPES AND PROVIDE ALL REQUIRED MOUNTING ACCESSORIES. FOR FIRE-RATED CEILING ASSEMBLIES, VERIFY ALL RECESSED LUMINAIRE HOUSINGS ARE FIRE-RATED OR

    PROVIDE FIRE-RATED, DROP-OVER ENCLOSURES OR TENT LUMINAIRE. VERIFY THAT DROP-OVER ENCLOSURES OR TENTS ALLOW FOR AIR SPACE AROUND LUMINAIRE PER MANUFACTURER'S RECOMMENDATIONS.

    ROOM CONTROLLERLMRC-213

    NEUTRAL WHT

    HOT BLK120/277

    LIGHTING LOAD (b)

    LIGHTING LOAD (c)

    LMDC-100OCCUPANCY SENSOR

    DLM WALLSWITCH

    LMSW-102

    RJ45(TYP)

    LMRJ SERIESPRE-TERMINATED

    CABLES.

    NOTES:

    -DEVICES ARE PRESET FOR PLUG n' GO™ OPERATION.

    -ALL ROOMS ARE STAND ALONE.

    -NUMBER OF ZONES ("a" "b" ETC) INDICATED NUMBER OF RELAYS REQUIRED IN A ROOM.

    -THE ROOM CONTROLLER DEFAULTS TO MULTI-LEVEL AUTOMATIC-ON/AUTOMATIC OFF.

    DLM WALLSWITCH

    LMSW-101

    a

    bc

    a

    -REUSE EXISTING LIGHTING CIRCUIT IN ROOM. RE-ROUTE LINE VOLTAGE TO ROOM CONTROLLER AS REQUIRED.

    IN EXPOSED FINISHED SPACES, PROVIDE CABLE IN RACEWAY.

    PROVIDE LEGRAND STEEL WIREMOLD V700 SERIES OR EQUAL. RACEWAY

    COLOR SHALL MATCH RACEWAY USED FOR RECEPTACLES & DATA.

    LMLS-400PHOTOSENSOR

    -DAYLIGHT SENSOR SHALL AUTOMATICALLY DIM LIGHTS LABELED 'c' TO A PREDETERMINED LIGHT LEVEL.

    LIGHTING LOAD (a)

    CLASS 2 0-10V CONTROL WIRING

    ISS

    EF

    OR

    P

    LANO EN

    G

    INEER

    ONT

    MA

    NA

    LICENSED

    GARTH L.

    STEVENS

    No. 11492 PE

    REV. DESCRIPTION DATE

    REVIEWED BY:

    DRAWN BY:

    SHEET

    DATE

    SHEET TITLE

    MO

    NT

    AN

    AS

    TA

    TE

    UN

    IV

    ER

    SIT

    Y

    MSU-CPDCMONTANA STATE UNIVERSITY

    BOZEMAN, MONTANA

    PHONE: 406.994.5413

    FAX: 406.994.5665

    6159.001

    CL

    AS

    SR

    OO

    MR

    EN

    OV

    AT

    ION

    S 2

    018

    RE

    ID H

    AL

    L 4

    52

    10

    0%

    CO

    NS

    TR

    UC

    TIO

    N D

    RA

    WIN

    GS

    RMGS

    ELECTRICAL

    ABBREVIATIONS &

    SYMBOLS

    E001

    03/19/2018

    PR

    OJE

    CT

    #1

    PPA#18-2011

    N.T.S.1REID 452 LIGHTING CONTROL DIAGRAM

  • LV

    OS

    P

    R4

    LV

    A B C

    1

    2

    3

    abc

    a

    a

    a b b c c

    ccbb

    b b c c

    a

    B1 B1 B1 B1 B1

    B1

    B1B1

    B1B1

    B1B1

    B1B1

    B1

    1 TYP.

    GENERAL ELECTRICAL NOTESA. ELECTRICAL DEVICES AND LIGHTS SHOWN IN GREY ARE EXISTING TO

    REMAIN. ELECTRICAL DEVICES AND LIGHTS SHOWN IN DASHED BLACK & SPECIFICALLY NOTED AS 'DEMO' ARE TO BE DEMOLISHED, UNO.

    B. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS, CONDUITS, DIFFUSERS, BOXES, AND OTHER ITEMS THROUGHOUT THIS PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.

    C. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING OF FLOORS, WALLS, CEILINGS, AND ROOFS TO PERFORM THE REQUIRED WORK DEPICTED IN THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING OF HOLES TO THE SATISFACTION OF THE ARCHITECT/ENGINEER.

    KEY NOTES:#

    A B C

    1

    2

    3

    DEMO (TYP. 17)

    DEMO

    DEMO DEMO

    2

    2 2

    ISS

    EF

    OR

    P

    LANO EN

    G

    INEER

    ONT

    MA

    NA

    LICENSED

    GARTH L.

    STEVENS

    No. 11492 PE

    REV. DESCRIPTION DATE

    REVIEWED BY:

    DRAWN BY:

    SHEET

    DATE

    SHEET TITLE

    MO

    NT

    AN

    AS

    TA

    TE

    UN

    IV

    ER

    SIT

    Y

    MSU-CPDCMONTANA STATE UNIVERSITY

    BOZEMAN, MONTANA

    PHONE: 406.994.5413

    FAX: 406.994.5665

    6159.001

    CL

    AS

    SR

    OO

    MR

    EN

    OV

    AT

    ION

    S 2

    018

    RE

    ID H

    AL

    L 4

    52

    10

    0%

    CO

    NS

    TR

    UC

    TIO

    N D

    RA

    WIN

    GS

    RMGS

    ELECTRICAL

    LIGHTING PLAN

    E100

    03/19/2018

    PR

    OJE

    CT

    #1

    PPA#18-2011

    1/4" = 1'-0"2REID 452 LIGHTING RENOVATION PLAN

    1/4" = 1'-0"1REID 452 LIGHTING DEMOLITION PLAN

    1 ALL NEW LIGHTING SHALL BE CIRCUITED VIA EXISTING BRANCH CIRCUIT PREVIOUSLY USED FOR LIGHTING WITHIN THE SPACE, WITH NEW CONTROLS. SEE SHEET E001 FOR LUMINAIRE SCHEDULE AND LIGHTING CONTROL DIAGRAM.

    DEMO EXISTING DIMMER SWITCH AND IT'S (2) ASSOCIATED LIGHT FIXTURES & WIRING. PATCH CEILING AS REQUIRED.

    2

  • WAPJ

    SS

    S S

    WAP

    J

    420 418

    419

    417

    416

    415 413

    412 409 408 407 405

    414 411

    431

    423A

    422

    425

    426 427424

    421A

    421

    428 429 432 434 435 436 437

    451450

    449

    448

    447

    446

    445

    444

    443

    442

    441

    440

    430

    458

    454 455

    456457

    446A 457A

    402

    401

    404

    452

    453

    459

    460

    438

    433 406

    410

    403A

    403

    431A

    425A

    423

    DNDN

    UP DN

    DN

    DNDN

    DN

    DN

    GENERAL ELECTRICAL NOTESA. ELECTRICAL DEVICES AND LIGHTS SHOWN IN GREY ARE EXISTING TO

    REMAIN. ELECTRICAL DEVICES AND LIGHTS SHOWN IN DASHED BLACK & SPECIFICALLY NOTED AS 'DEMO' ARE TO BE DEMOLISHED, UNO.

    B. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS, CONDUITS, DIFFUSERS, BOXES, AND OTHER ITEMS THROUGHOUT THIS PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.

    C. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING OF FLOORS, WALLS, CEILINGS, AND ROOFS TO PERFORM THE REQUIRED WORK DEPICTED IN THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL PATCHING OF HOLES TO THE SATISFACTION OF THE ARCHITECT/ENGINEER.

    A B C

    1

    2

    3

    NEW WIREMOLD SYSTEM

    PROJECTOR

    1

    2

    3

    4

    4

    6

    6

    7TYP.

    A B C

    1

    2

    3

    PROJECTOR (RELOCATE)

    DEMO DEMO

    DEMO

    EXISTING WIRELESS ACCESS POINT SHALL REMAIN. PROTECT DURING CONSTRUCTION.

    DEMO

    4

    4

    DEMO

    EXISTING SPEAKER & ASSOCIATED CABLING TO BE REMOVED BY MSU IT (TYP. 2).

    9

    8 8

    9

    REID 452

    PROJECT LOCATION

    LOCATION OF EXISTING ELECTRICAL PANEL 'Z'

    5

    KEY NOTES:#

    NOTES:1. FIELD VERIFY FINAL LOCATION. COORDINATE WITH PODIUM AND MSU IT.2. PAINT VERTICAL WALL CHANNEL TO MATCH WALL COLOR.3. INCLUDE ALL REQUIRED COMPONENTS AND MANUFATURER ACCESSORIES FOR A COMPLETE SYSTEM.

    END COMPONENT AS REQUIRED: CONNECTRAC IN-EC, OR EQUAL.

    AV/DUPLEX RECEPTACLE COMBO BOX: CONNECTRAC

    PS-A-288, OR EQUAL.IN-CARPET WIREWAY:

    CONNECTRAC IN-048-GR, OR EQUAL

    VERTICAL WALL CHANNEL TO CEILING: CONNECTRAC

    AC-WC-144-AL, OR EQUAL

    FLOOR

    WALL

    ISS

    EF

    OR

    P

    LANO EN

    G

    INEER

    ONT

    MA

    NA

    LICENSED

    GARTH L.

    STEVENS

    No. 11492 PE

    REV. DESCRIPTION DATE

    REVIEWED BY:

    DRAWN BY:

    SHEET

    DATE

    SHEET TITLE

    MO

    NT

    AN

    AS

    TA

    TE

    UN

    IV

    ER

    SIT

    Y

    MSU-CPDCMONTANA STATE UNIVERSITY

    BOZEMAN, MONTANA

    PHONE: 406.994.5413

    FAX: 406.994.5665

    6159.001

    CL

    AS

    SR

    OO

    MR

    EN

    OV

    AT

    ION

    S 2

    018

    RE

    ID H

    AL

    L 4

    52

    10

    0%

    CO

    NS

    TR

    UC

    TIO

    N D

    RA

    WIN

    GS

    RMGS

    ELECTRICAL POWER

    & SIGNAL PLAN

    E200

    03/19/2018

    PR

    OJE

    CT

    #1

    PPA#18-2011

    1/4" = 1'-0"4REID 452 ELECTRICAL RENOVATION PLAN

    1/4" = 1'-0"3REID 452 ELECTRICAL DEMOLITION PLAN

    1 RE-ROUTE 120V FEEDER AS REQUIRED FROM EXISTING PROJECTOR LOCATION TO NEW PROJECTOR. RE-USE EXISTING CIRCUIT.

    PROVIDE SURFACE-MOUNT RACEWAY FOR ALL NEW RECEPTACLES SHOWN. SEE ARCHITECTURAL PLANS FOR MOUNTING HEIGHT OF RACEWAY & RECEPTACLES. BASE BID: PROVIDE LEGRAND STEEL WIREMOLD V700 SERIES. ALTERNATE BID: PROVIDE LEGRAND STEEL WIREMOLD 3000 SERIES.

    PROVIDE IN-CARPET & VERTICAL WIREWAY SYSTEM PER DETAIL 2 ON THIS SHEET.

    FEED NEW SURFACE-MOUNT RACEWAY FROM THE EXISTING RECEPTACLE IN THIS LOCATION. EXISTING RECEPTACLE BECOMES SURFACE MOUNT 1G JUNCTION BOX W/ BLANK COVERPLATE.

    RE-USE EXISTING RECEPTACLE FEEDER(S) FROM EXISTING PANEL 'Z' INTO ROOM 452.

    COORDINATE EXACT LOCATION OF NEW SPEAKER WITH MSU IT. PROVIDE SURFACE-MOUNT RACEWAY (LEGRAND STEEL WIREMOLD V700 SERIES) FROM NEW SPEAKER LOCATION UP TO ACCESSIBLE CEILING SPACE. PROVIDE PULL STRING FOR CABLING.

    CIRCUIT NEW RECEPTACLES VIA EXISTING RECEPTACLE CIRCUIT IN ROOM, MARKED 'Z-8' ON AS-BUILT PANEL DIRECTORY. FIELD VERIFY EXACT AS-BUILT CIRCUITING.

    REMOVE EXISTING DEVICE, WIREMOLD, AND IT'S CIRCUIT, BACK TO NEAREST UPSTREAM DEVICE TO MAINTAIN ORIGINAL CIRCUIT CONTINUITY.

    REMOVE EXISTING RECEPTACLE AND IT'S CIRCUIT, BACK TO NEAREST UPSTREAM DEVICE TO MAINTAIN ORIGINAL CIRCUIT CONTINUITY.

    2

    3

    4

    1" = 30'-0"1LEVEL 4 OVERALL PLAN

    5

    6

    7

    N.T.S.2ELECTRICAL IN-CARPET & VERTICAL WIREWAY DETAIL

    8

    9

  • 312A313A 313B

    313

    314

    315

    323

    316

    317 318 319 320

    321

    322

    306

    306B

    306C307

    312F312E312D

    312C

    312B 312

    324

    305B

    305A

    305

    304 303 302

    301

    BELOWOPEN TO

    DOWN

    UP

    COBLEIGHUP TO

    ROBERTS 319

    PROJECT LOCATION

    72

    0 S

    . Tr

    acy

    Ave

    ., B

    ozem

    an, M

    T

    dRA-

    Arc

    hite

    ct.c

    om

    dRA

    den

    nis

    Raf

    fens

    perg

    erArc

    hite

    ct

    REV. DESCRIPTION DATE

    REVIEWED BY:DRAWN BY:

    SHEET

    DATE

    SHEET TITLE

    MO

    NT

    AN

    AST

    AT

    E U

    NIV

    ER

    SIT

    Y

    MSU-CPDCMONTANA STATE UNIVERSITY

    BOZEMAN, MONTANAPHONE: 406.994.5413

    FAX: 406.994.5665

    Consultant #:1710

    CL

    ASS

    RO

    OM

    RE

    NO

    VA

    TIO

    NS

    2018

    RO

    BER

    TS H

    ALL

    31

    9 1

    00

    % C

    ON

    STR

    UC

    TIO

    N D

    RA

    WIN

    GS

    MOSAICDRA

    COVER

    A00003/19/2018

    PR

    OJE

    CT

    #1

    PPA#18-2011

    CLASSROOM RENOVATIONS 2018

    PROJECT DIRECTORY

    PROJECT #1

    1" = 20'-0"ROBERTS HALL THIRD FLOOR VICINITY MAP1

    ARCHITECTURAL SHEETS

    A000 COVERA001 GENERAL & CODE INFORMATIONA100 DEMO PLANSA101 FLOOR PLAN, REFLECTED CEILING PLAN, & DETAILSA200 ELEVATIONS

    PROJECT DIRECTORY

    MECHANICAL/ELECTRICAL/PLUMBING ENGINEERING:

    2880 TECHNOLOGY BLVD. WESTP.O. BOX 1113BOZEMAN, MT 59771-1113(406) 587-0721

    CONTACT: Erik Renna, [email protected]

    ARCHITECT:

    MOSAIC ARCHITECTURE, P.C.428 North Last Chance GulchHelena, MT 59601Ph. 406-449-2013,

    CONTACT(S) : Matt Aune, [email protected]

    720 S. TRACEY AVEBOZEMAN, MT (406) 581-8759

    CONTACT: DENNIS RAFFENSPERGER [email protected]

    dRAdennis Raffensperger Architect

    CONSULTING ARCHITECT:

    MEP SHEETS

    CLASSROOM: REID HALL 452

    ROBERTS HALL 319 ROBERTS HALL 321

    ADDRESS:MONTANA STATE UNIVERSITY

    BOZEMAN, MT 59717

    E100 ELECTRICAL LIGHTING PLANME100 MECHANICAL & ELECTRICAL PLAN

  • 1. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND ALL CONDITIONS OF THE EXISTING SITE.

    2. RESPONSIBILITY FOR ON-SITE COORDINATION OF CONSTRUCTION ACTIVITIES IS WITH THE GENERAL CONTRACTOR.

    3. ALL SHOP DRAWING DIMENSIONS TO BE CHECKED AND VERIFIED IN THE FIELD BY THE CONTRACTOR WHO WILL BE RESPONSIBLE FOR SAME.

    4. GENERAL CONTRACTOR IS RESPONSIBLE FOR PATCHING OF ANY SURFACES DAMAGED DURING THE CONSTRUCTION PROCESSES. SURFACES ARE TO BE PATCHED FLUSH WITH EXISTING. MATCH EXISTING ADJACENT FINISH OR APPLY NEW FINISH AS SCHEDULED.

    5. GENERAL CONTRACTOR TO COORDINATE ALL CUTTING AND PATCHING REQUIRED BY WORK OF ALL TRADES AND AS APPROVED BY ARCHITECT/ ENGINEER.

    6. GENERAL CONTRACTOR TO PROVIDE ALL REQUIRED BLOCKING, ANCHORAGES FOR ACCESSORIES, MILLWORK, TRIM, GRAB BARS, CABINETS, SHELVING, TOILET ACCESSORIES, HANDRAILS, OTHER FLUSH OR SEMI-RECESSED EQUIPMENT, MECHANICAL AND ELECTRICAL ITEMS, OR AS SPECIFIED.

    7. IN GENERAL, REPETITIVE DETAILS DRAWN ARE SHOWN IN FULL ONLY ONCE. REPETITIONS MAY NOT BE COMPLETE IN EVERY DETAIL AS SHOWN IN THE ORIGINAL DETAIL.

    8. PARTITIONS ARE LOCATED BY ONE OF THE FOLLOWING METHODS:9. a) WHERE POSSIBLE, BY RELATIONSHIP TO ADJACENT STRUCTURE.10. b) TYPICAL RELATIONSHIP TO LARGE SCALE DETAILS.11. c) BY DIMENSION FROM STRUCTURE OR PARTITION ALREADY LOCATED.12. d) BY DIMENSION FROM GRID LINES.13. e) DIMENSIONS ARE TO FACE OF STUD.14. DIMENSIONS ARE SHOWN ON THE DRAWINGS. DO NOT SCALE THE DRAWINGS.15. ALL HEIGHTS ARE DIMENSIONED FROM THE TOP OF SUBFLOOR UNLESS NOTED OTHERWISE.16. EDGE TRIM AROUND ALL EDGES OF GYPSUM BOARD WALLS ABUTTING OTHER MATERIALS. LEAVE

    1/4" GAP FROM WALL FOR SEALANT.17. WHERE COLUMNS AND STUD WALLS ALIGN, GYPSUM BOARD TO BE CONTINUOUS OVER COLUMNS

    OR BOXED AROUND COLUMN IF COLUMN PROJECTS BEYOND WALL.18. GYPSUM BOARD IN TOILET AREAS AND OTHER AREAS INDICATED AS "WET AREAS" TO BE WATER

    RESISTANT GYPSUM BOARD.19. BRING TO THE ATTENTION OF THE ARCHITECT ANY CONDITION OR AREA OF FINISH THAT IS IN

    QUESTION OR NOT NOTED.20. SEAL OPENINGS IN FLOOR AROUND DUCTS, PIPES, VENTS, SOILPIPES, TRAPS, CONDUIT, ETC.

    ACCORDING TO DETAILS & SPECIFICATIONS.21. ALL PENETRATIONS THROUGH WALLS ABOVE CEILING AND BELOW STRUCTURE ARE TO BE CLOSED

    TIGHT AROUND PENETRATION. USE FIRESAFING WHERE FIRE-RATED WALLS AND FLOOR/CEILINGS ARE PENETRATED. SEE DETAILS AND SPECIFICATIONS.

    22. DUST BARRIERS MUST BE INSTALLED WHEREVER NEW WORK IS ADJACENT TO OCCUPIED AREAS. BARRIERS MUST BE SEALED TO INSURE NO DUST TRANSMISSION TO OCCUPIED SPACES.

    23. CONTRACTOR TO VERIFY ALL EQUIPMENT SIZES AND ROUGH-IN NEEDS AND ADJUST TO EXISTING CONDITIONS PRIOR TO BEGINNING WORK.

    24. SEE MECHANICAL & ELECTRICAL FOR ADDITIONAL PLACEMENT OF SLEEVES & HANGERS REQUIRED BY WORK.

    25. ALL MECHANICAL AND ELECTRICAL LINES TO BE INSTALLED TIGHT TO STRUCTURE WHERE POSSIBLE.

    26. HEATING, PLUMBING AND ELECTRICAL PLANS WHERE SHOWN DIAGRAMMATICALLY ARE INTENDED TO INDICATE CAPACITY, SIZE AND LOCATION AND GENERAL ARRANGEMENTS. ALL NECESSARY FEATURES OF RELATED CONSTRUCTION WILL BE REQUIRED AS IF SHOWN IN DETAIL.

    27. WHERE MECHANICAL AND ELECTRICAL EQUIPMENT LOCATIONS CONFLICT ELECTRICAL, LIGHT FIXTURE LOCATIONS SHALL TAKE PRECEDENCE.

    28. WHERE PLUMBING OCCURS IN STUD WALL WITH HORIZONTAL OR VERTICAL PIPING, STUDS SHALL BE CONSTRUCTED DEEP ENOUGH TO ACCOMMODATE PIPING. SAME FOR ALL ELECTRICAL PANELS.

    29. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NEW MATERIALS (U.N.O.) AND QUALIFIED CRAFT PERSONS TO COMPLETE THE WORK.

    30. CONSTRUCTION DOCUMENTS SHOW THE DESIGN INTENT OF THE PROJECT AND MAY NOT SHOW MINOR DETAILS OF PROPOSED INSTALLATIONS. THE INCLUSION OF THESE MINOR DETAILS IS IMPLIED TO PROVIDE A COMPLETE PROJECT AND ARE TO BE INCLUDED AS A PART OF A BID.

    31. IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSPECT EXISTING CONDITIONS PRIOR TO PROCEEDING WITH EACH INSTALLATION OR PART OF THE WORK. DISCREPANCIES MUST BE REPORTED TO THE ARCHITECT PRIOR TO PROCEEDING.

    32. THE GENERAL CONTRACTOR IS TO COORDINATE THE INSTALLATION OF MATERIALS AND WORK OF OTHERS WHO ARE NOT SUB-CONTRACTORS TO THE G.C., YET ARE REQUIRED TO PROVIDE A COMPLETED PROJECT. AREAS OF WORK REQUIRING COORDINATION INCLUDE BUT ARE NOT LIMITED TO THOSE INDICATED AS N.I.C. ON THE CONSTRUCTION DOCUMENTS.

    33. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR COORDINATION OF WORK.34. IN THE CASE OF CONTRADICTIONS BETWEEN DRAWINGS OR BETWEEN DRAWINGS AND

    SPECIFICATIONS, ASSUME THE MORE COSTLY APPROACH FOR BIDDING PURPOSES. BRING ALL CONTRADICTIONS TO THE ATTENTION OF THE ARCHITECT.

    35. THE CONSTRUCTION DOCUMENTS CONSIST OF THE CONSTRUCTION DRAWINGS AND SPECIFICATIONS INCLUSIVELY. SOME ITEMS MAY BE SHOWN ONLY ON THE DRAWINGS, OR INDICATED ONLY IN THE SPECIFICATIONS. FOR EXAMPLE, THE SPECIFICATIONS MAY SAY TO PAINT ALL EXPOSED STRUCTURAL STEEL, BUT THIS MAY NOT BE CALLED OUT ON ALL OF THE DRAWINGS.

    36. ALL WORK SHALL COMPLY WITH STATE AND LOCAL CODES. CONTRACTOR SHALL INSURE FULL COMPLIANCE WITH FLAME SPREAD REQUIREMENTS.

    37. CONTRACTOR SHALL PROMPTLY REMOVE ALL WASTE MATERIALS AND LEAVE PREMISES AND SITE CLEAN.

    38. THE CONTRACTOR SHALL PROVIDE ALL CEILING AND/OR WALL ACCESS PANELS/DOORS AS REQUIRED BY THE AIR CONDITIONING, PLUMBING & ELECTRICAL SYSTEMS, PROVIDE APPROVED ASSEMBLIES W/ SELF-CLOSING DEVICES IN RATED CONSTRUCTION. (PAINT TO MATCH ADJACENT WALL COLOR)

    39. ALL PENETRATIONS OF FIRE RESISTIVE CONSTRUCTION SHALL BE PROTECTED WITH APPROVED FIRE ASSEMBLIES.

    40. ELECTRICAL OUTLETS AND LIGHTING ARE ONLY SHOWN SPORATICALLY ON ARCHITECTURAL "A" SHEETS WHERE PLACEMENT OF SUCH IS CRITICAL TO PARTICULAR AESTHSTICS. ELECTRICAL INDICATIONS ON "A" SHEETS ARE NOT MEANT TO BE COMPLETE OR EXAUSTIVE. SEE ELECTRICAL DRAWINGS FOR ALL ELECTRICAL AND DATA FEATURES.

    DRAWING SET NOTE: THESE DRAWINGS ARE TO BE UTILIZED AS A COMPLETE SET FOR BIDDING AND CONSTRUCTION. INDIVIDUAL SECTIONS OF DRAWINGS SHOULD NOT BE SEPARATED FROM THE ENTIRE SET. IMPORTANT NOTES FOR ONE AREA OF WORK MAY BE INCLUDED IN OTHER AREAS IN THE DRAWINGS. ALL CONTRACTORS AND SUPPLIERS MUST REVIEW ENTIRE DRAWING SET AND SPECIFICATIONS.

    GENERAL NOTES:

    1. THE GENERAL CONDITIONS TO THE CONTRACT FOR THE CONSTRUCTION OF BUILDINGS: THE MONTANA STATE UNIVERSITY GENERAL CONDITIONS TO THE CONTRACT FOR CONSTRUCTION, HEREINAFTER REFERRED TO AS THE GENERAL CONDITIONS,

    2. CONTRACT DOCUMENTS INCLUDE THE ARCHITECT'S DRAWINGS, SPECIFICATIONS, GENERAL CONDITIONS, AGREEMENT (BUILDING CONTRACT) AND ALL ADDENDA. THEY ARE TO INCLUDE ALL LABOR, EQUIPMENT, AND MATERIALS NECESSARY FOR THE PROPER EXECUTION OF THE WORK EXCEPT AS MAY BE SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS OR FOR WHICH SEPARATE PRICES MAY BE ASKED IN THE BID PROPOSAL.

    3. REGULATIONS, TAXES AND PERMITS: THE WHOLE OF THE WORK IS TO BE EXECUTED IN STRICT ACCORDANCE WITH THE REGULATIONS AND CODES OF THE GOVERNMENTAL AGENCIES WHOSE JURISDICTION IS APPLICABLE.

    GENERAL CONDITIONS:

    @ atA.B. anchor boltAC asphaltic concreteA/C air conditioningACC PNL access panelACOUST acousticalACT acoustical ceiling tileAD area drainADJ adjacentA.F.F. above finished floorA.I.B. air infiltration barrierALT alternateALUM aluminumANOD anodizedAPPROX approximateAPPRD approvedARCH architectAUTO automaticBBD bulletin boardBD boardBITUM bituminuousBL building lineBLDG buildingBLK blockBLKG blockingBLDG buildingBLKG blockingBM beam/bench markBO by ownerB.O. bottom ofBOT bottomBRK brickBRG bearingB/S building standardBSBD baseboardBTW betweenBTM/BOTT bottomBTWN betweenB.O.W. bottom of wallBU built upCAB cabinetCAP capacityCB catch basinCBD chalk boardCB-ICF cement based insulated concrete formCD ceiling diffuserC.F. cement fiber (siding and trim)/cubic feetCL centerlineC.B. catch basinC.C. center to centerCDX exterior grade plywoodC.T. ceramic tileCG ceiling grill/corner guardCH channelCI cast iron/cubic incheseCJ control jointCLG ceilingC.L.L. contract limit lineCL center lineCLO closetCLR clearCMU concrete masonry unitCMNT cementCMT ceramic mosaic tileCO clean outCOL/COLS column/columnsCONC concreteCOND conditionCONF conferenceCONN connectionCONST constructionCTRD centeredCONT continuousCONTR contractorCORR corridorCPT carpetCR ceiling registerCT ceramic tileCTR counterCUH cabinet unit heaterCW cold waterCY cubic yardDBL doubleDEPT departmentDF drinking fountainDIA diameterDIAG diagonalDIM dimensionDISP dispenserDL dead loadDN downDP demountable partitionDR doorDWR drawerDS downspoutDTL/DET detailDWG drawingE eastEA eachEIFS exterior insulation finish systemE.J. expansion jointEL/ELEV elevation - height/elevatorELEC electricalENCL enclosureEO electrical outletEP electrical panelEQ equalEQUIP equipmentEWC electrical water coolerEWH electrical water heater(E)/EXIST existingEWC electrical water coolerEWH electrical water heaterEXH exhaustEXP expansionEXT exteriorEWA/EW exterior wall assemblyFA fire alarm/floor-ceiling assemblyFABR fabricateFAH fire alarm hornFAS fire alarm stationFBR face brickFD floor drainFDN/FDTN foundationFFHB frost free hose bibFG finish gradeFH fire hydrantFIN. FLOOR top of floor sheathingFIN finishFIO furnished and installed by ownerFIX/FXTR fixtureF.O. face ofFDN foundationFEC fire extinguisher cabinetFF finished floorFLR/FL floorFLUOR fluorescentFND feminine napkin dispenser/disposalFOC face of concreteFOIC furnished by owner and installed byFOS face of studFOW face of wallFT foot or feetFTG footingFTIC furnished by tenant & installed by

    contractorFE fire extinguisherGA gaugeGB grab barGAF brand name roofing productGALV galvanized G.C. general contractorGEN generalGI galvanized ironGL glassGLU LAM or G.L.B. glue laminated beamGRD grade/gridGS galvanized steelGWB gypsum wall boardGYP gypsumHB hose bibHC hollow core/handicappedHD BD Hard boardHDR headerHOR horizontalHP high pointHR hourHT heightHTG heatingHVAC heating, ventilation, air conditioningHW hot water

    IN inchINCL includedINFO informationINSUL insulationINT interiorIWA/IW interior wall assemblyJAN janitorJST joistJT jointLAV lavatoryLF lineal footLTG lightingLVR louverM men'sMNFR/MANUF. manufacturerMAT materialMAX maximumMECH mechanicalMC medicine closetMDF medium density fiber boardMEMB membraneMEZZ mezzanineMH man holeMIN minimumMIRR mirrorMISC miscellaneousMO masonry openingMTL metalMULL mullionN northNA not applicableNAT naturalNIC not in contractNO numberNTS not to scaleOA over allO.C. on centerOD outside diameterOH overhead/opposite handOPNG openingOPP oppositePART.BD. particle boardPART’N/PART partitionPC precast concretePL platePLAM plastic laminatePLAST plasticPLWD plywoodPND paper napkin dispenserPNL panelPR pairPSL parallel strand lumberPT pointPTD paper towel dispenserPTD/R paper towel dispenser/receptaclePVMT pavementP.V.C. polyvinylchlorideQTY quantityR/RAD radiusR riserRA roof/ceiling assemblyRB rubber baseRD roof drainRDWD redwoodRE regardingREC recessedREF referenceREFR refrigeratorREINF reinforcingREQD/REQ requiredRES resilientRM roomRO rough openingRV roof ventR&S rod and shelfS southSACT suspended acoustical ceiling tileSAT suspended acoustical tile ceilingSC solid coreSCD seat cover dispenserSCHED scheduleSD soap dispenserSECT sectionSF square feetS.G. supply grillSGL safety glassSHLVS shelvesSHLVNG shelvingSHT sheetSHTG sheathingSHWR showerSIM similarSIM. similarS.I.P. structural insulated panelSLNT sealantSM surface mountedSOG slab on gradeS.STL./SS stainless steelS&P shelf and poleSPEC specificationsSS service sinkSTD standardSTL steelSTOR storageSTRUCT/STRUC structuralSUBFLR subfloorSUSP suspendedS&V stain and varnishSV sheet vinylSY square yardT tread/thermostatTB towel barTEL telephoneTEMP temperatureT&G tongue and grooveT.ALUM. tubular aluminumT.B. test boreTHK thickTHRU throughT.J.I./TJI Truss Joist IncorporatedT.O. top ofT.O.B. top of beamTOC top of concreteT.O.P. top of plateT.O. FTG top of footingT.O.S. top of steelT.O. SL. top of slabT.O.W. top of wallTP toilet paper holderTPD toilet paper dispenserTPG toppingTR/TRD treadT.S. tubular steelTV televisionTYP typicalUBC uniform building codeUG undergroundUH unit heaterUNO unless noted otherwiseUR urinalUV unit ventilatorVAC vacuum outletVAR variesVB vapor barrierVCT vinyl composition tileVEN veneerVERT verticalVEST vestibuleVG vertical grainVIN vinylVP veneer plasticVT vinyl tileVWC vinyl wall coveringW west/women/widthW/ withW/O with outWB wood baseWC water closetWD woodW/D washer/dryerWGW windowWGL wire glassWH water heaterWM wire meshWNDW/WDW windowWP waterproofWR water resistantWS weatherstripWSCT wainscotWT weightWWF welded wire fabricWWM welded wire meshX byYH yard hydrantYD yard

    ABBREVIATIONS: REFERENCE SYMBOLS:

    SCALE

    SECTIONS / WALL SECTIONS

    INTERIOR ELEVATIONS

    DETAIL CALLOUT

    ROOM NAME, NUMBER, AND AREA

    GRID LINES:NUMBERS LEFT TO RIGHTLETTERS TOP TO BOTTOM

    ELEVATION TAG,TYP. MAIN FLOOR = 100' - 0"

    DRAWING TITLE

    FIRE EXTINGUISHER, SEE CODE PLANS

    SHEET NUMBER

    DRAWING NUMBER

    SHEET NUMBER

    DRAWING NUMBER

    SHEET NUMBER

    DRAWING NUMBER

    FE

    FE

    WITH CABINET

    WALL-HUNG, NO CABINET

    A1-0113

    View Name1/8" = 1'-0"23

    1

    A101 SIM

    A101

    1

    SIM

    Room name

    150 SF101

    ##

    ##

    NameElevation1

    A101 SIM

    Room name

    101150 SF

    SUMMARY CODE REVIEW SEE CODE PLAN, THIS SHEET

    BUILDING SUMMARY

    THIS PROJECT SHALL COMPLY WITH THE LATEST EDITION OF CODES ADOPTED BY THE STATE OF MONTANA AND THE CITY OF BOZEMAN:

    2012 International Building Code (IBC)2012 International Mechanical Code (IMC)2012 International Fuel Gas Code (IFGC)2012 Uniform Plumbing Code (IAMPO)2014 National Electrical Code (NEC)2012 International Fire Code (IFC)2012 International Energy Conservation Code (IECC)

    APPLICABLE BUILDING CODES

    Project Description:CLASSROOM REMODEL AT THE MONTANA STATE UNIVERISTY

    OCCUPANCY CLASSIFICATION: BUSINESS GROUP BEDUCATIONAL OCCUPANCIES FOR STUDENTS ABOVE 12TH GRADE

    TYPE OF CONSTRUCTION: 3B

    SPRINKLER SYSTEM: NONE EXISTING NONE PROPOSED

    PROPOSED SIZE:MAINTAINS EXISTING SIZE 499 SQ FT

    OCCUPANT LOADS:BUILDING SPACES:THIS PROJECT IS NOT CHANGING BUILDING AREA OR OCCUPANCY TYPE. THEREFORE IS NOT INCREASING OCCUPANT LOAD

    EXITING, Main Floor:THIS IS AN INTERIOR REMODELING PROJECT WITH NO CHANGE ON EXISTING EXITING.

    A

    3

    2

    1

    B C

    499 SF

    ROBERTS

    319

    72

    0 S

    . Tr

    acy

    Ave

    ., B

    ozem

    an, M

    T

    dRA-

    Arc

    hite

    ct.c

    om

    dRA

    den

    nis

    Raf

    fens

    perg

    erArc

    hite

    ct

    REV. DESCRIPTION DATE

    REVIEWED BY:DRAWN BY:

    SHEET

    DATE

    SHEET TITLE

    MO

    NT

    AN

    AST

    AT

    E U

    NIV

    ER

    SIT

    Y

    MSU-CPDCMONTANA STATE UNIVERSITY

    BOZEMAN, MONTANAPHONE: 406.994.5413

    FAX: 406.994.5665

    Consultant #:1710

    CL

    ASS

    RO

    OM

    RE

    NO

    VA

    TIO

    NS

    2018

    RO

    BER

    TS H

    ALL

    31

    9 1

    00

    % C

    ON

    STR

    UC

    TIO

    N D

    RA

    WIN

    GS

    AuthorChecker

    GENERAL & CODEINFORMATION

    A00103/19/2018

    PR

    OJE

    CT

    #1

    PPA#18-2011

    1/4" = 1'-0"ROBERTS 319 CODE PLAN3

    0' 2' 4' 8' 16'

  • A

    3

    2

    1

    B C

    DEMOLISHED

    EXISTING WALL TO REMAIN

    DEMO LEGEND

    2.

    2.

    2.

    1.

    3.

    4.

    3. 3. 3.

    5.

    6.

    A. PATCH AND PREP ALL WALLS FOR PAINT UNLESS OTHERWISE INDICATED.B. VERIFY ALL CONDITIONS AND COORDINATE WITH ALL DISCIPLINES OF CONTRACT.

    UNDOCUMENTED FIELD CHANGES MAY HAVE OCCURRED AND ARE TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT WHEN DISCOVERED.

    C. WHERE DEMOLITION IS INDICATED, WALLS SHALL BE REMOVED AND CEILING SHALL BE PATCHED, REPAIRED AND PAINTED TO MATCH EXISTING.

    D. UNLESS DEMOLITION IS INDICATED, PATCH AND PROTECT EXISTING CEILING.E. COORDINATE ALL MECHANICAL, ELECTRICAL, FIRE SYSTEMS, COMMUNICATIONS AND UTILITY

    SHUT-DOWNS WITH OWNER PRIOR TO REMOVING AND OR RELOCATING, PER MSU REQUIREMENTS.

    F. ALL DEMOLITION DRAWINGS ARE INTENDED TO SHOW GENERAL SCOPE OF WORK WITHIN THE INTENT OF THE PROJECT AND ARE NOT INTENDED TO EXCLUDE ANY DEMOLITION WORK NECESSARY FOR PRIOR COMPLETION OF THE WORK OUTLINED IN THE PROJECT DOCUMENTS. CONTRACTOR SHOULD ASSUME ADDITIONAL MINOR DEMOLITION ITEMS NOT SHOWN ON PLANS, NO ADDITIONAL PAYMENT WILL BE MADE FOR SUCH MINOR ELEMENTS.

    G. THESE DRAWINGS INDICATE STRUCTURAL AND NON-STRUCTURAL DEMOLITION THAT IS TO OCCUR TO MAKE WAY FOR NEW CONSTRUCTION. ADDITIONAL STRUCTURAL DEMOLITION WORK, CONSTRUCTION OR SHORING REQUIRING COORDINATION WITH NEW STRUCTURAL INS INDICATED ON THE STRUCTURAL DRAWINGS.

    H. SEE MECH. AND ELEC. DEMOLITION PLANS FOR SPECIFIC DEMO OF MECHANICAL AND ELECTRICAL SYSTEMS.

    I. SEE HAZARDOUS MATERIALS ABATEMENT REPORT FOR ADDITIONAL INFORMATION AND COORDINATION.

    GENERAL DEMOLITION NOTES:

    A

    3

    2

    1

    B C

    7.

    72

    0 S

    . Tr

    acy

    Ave

    ., B

    ozem

    an, M

    T

    dRA-

    Arc

    hite

    ct.c

    om

    dRA

    den

    nis

    Raf

    fens

    perg

    erArc

    hite

    ct

    REV. DESCRIPTION DATE

    REVIEWED BY:DRAWN BY:

    SHEET

    DATE

    SHEET TITLE

    MO

    NT

    AN

    AST

    AT

    E U

    NIV

    ER

    SIT

    Y

    MSU-CPDCMONTANA STATE UNIVERSITY

    BOZEMAN, MONTANAPHONE: 406.994.5413

    FAX: 406.994.5665

    Consultant #:1710

    CL

    ASS

    RO

    OM

    RE

    NO

    VA

    TIO

    NS

    2018

    RO

    BER

    TS H

    ALL

    31

    9 1

    00

    % C

    ON

    STR

    UC

    TIO

    N D

    RA

    WIN

    GS

    AuthorChecker

    DEMO PLANS

    A10003/19/2018

    PR

    OJE

    CT

    #1

    PPA#18-2011

    1/4" = 1'-0"ROBERTS 319 DEMO PLAN1

    DEMOLITION NOTES1. PREP FLOOR FOR CARPET AND NEW BASE

    2. REMOVE WHITEBOARD SURFACE ONLY; KEEP, PROTECT AND REFINISH WOODEN FRAME AS PART OF REMODEL

    3. REMOVE SHADES

    4. METAL WINDOW SILLS TO BE PREPPED FOR PAINT

    5. REPLACE GLASS IN 1/2LITE DOOR

    6. CUT & REMOVE CEILING TRIM ONLY WHERE TRIM CONFLICTS WITH NEW VERTICAL WIREMOLD

    7. KEEP AND PROTECT EXISTING CEILING.

    1/4" = 1'-0"ROBERTS 319 RCP DEMO3

    6.

  • A

    3

    2

    1

    B C

    A2001

    A2002

    A200 3

    A2004

    4'-0"

    1'-2

    "

    IN-CARPET TRACK FOR UMBILICAL. LOCATION TO BE FIELD VERIFIED

    P2

    PODIUM NIC. FOR REFERENCE ONLY

    P1

    P1

    P1

    3A101A200

    7

    Sim

    5

    A200Sim

    A

    3

    2

    1

    B C

    EXIST10'-8"

    14'-8"

    PROJECTOR INSTALL:PROJECTOR NIC. GC TO RELOCATE EXST PROJECTOR POLE AND MOUNT AS NECESSARY. GC TO INSTALL APPROPRIATE BACKING/SUPPORT. FINAL LOCATION TO BE FIELD VERIFIED.

    PROJECTION SCREEN INSTALL:GC TO PURCHASE AND INSTALL SCREEN AND APPROPRIATE MOUNTING HARDWARE. GC TO INSTALL APPROPRIATE BACKING/SUPPORT. FINAL LOCATION TO BE FIELD VERIFIED.

    NEW SHADES AT ALL WINDOWS. SEE SPEC

    ROOM FINISH LEGENDFLOOR FINISHES:

    BASE FINISHES:

    PAINTED GWB: PAINT COLOR OVER GYPSUM BOARD - TYP. U.N.O. COLOR AS INDICATED.

    PAINT COLOR SELECTIONS:P1- OFF WHITE . SHERWIN WILLIAMS "CREAMY" SW-7012. LRV 83P2- ACCENT COLOR: GRAY. SHERWIN WILLIAMS "ACIER" SW-9170. LRV 32

    WALL FINISHES:

    CARPET-CP3

    FLOOR FINISH NOTES:1. IF FINISHES ARE NOT CLEARLY INDICATED FOR AN AREA, CLARIFY INTENT WITH

    ARCHITECT.2. PROVIDE APPROPRIATE TRANSITION TRIM AT ALL MATERIAL CHANGES.3. TEST ALL SUBSTRATES TO VERIFY COMPLIANCE WITH FINISH MANUFACTURE'S

    SPECIFICATIONS PRIOR TO FLOORING INSTALLATION.4. PATCH, REPAIR, AND/OR GRIND ALL SUBSTRATES TO ACCEPTABLE LEVEL OF

    SMOOTHNESS/LEVELNESS PRIOR TO FLOORING INSTALLATION.5. FLOORING CHANGES FROM ROOM TO ROOM TO OCCUR DIRECTLY UNDER THE DOOR

    LOCATION.6. SAMPLES FOR ALL FINISHES MUST BE SUBMITTED TO AND APPROVED BY ARCHITECT

    PRIOR TO ORDERING.

    SEE ROOM FINISH SCHEDULE FOR LISTING OF MATERIALS .

    WALL FINISH NOTES:1. SEE INTERIOR ELEVATIONS FOR INTERIOR WINDOWS, SPECIAL WALL FINISHES, TRIM, ETC.2. IF FINISHES ARE NOT CLEARLY INDICATED FOR AN AREA, CLARIFY INTENT WITH ARCHITECT.3. PROVIDE APPROPRIATE TRANSITION TRIM AT ALL MATERIAL CHANGES.4. PROVIDE CLEAN, CONSISTENT CAULK JOINTS AT ABUTMENTS OF DISSIMILAR MATERIALS.5. PROVIDE METAL EDGING AT ALL GYPSUM BOARD EDGES THAT ABUT DISSIMILAR

    MATERIALS.

    CEILING FINISHES:

    EXST. 1 EXISTING CEILING TILE: TO KEEP & PROTECT EXISTING CEILING TILE & GRID

    CHAIR RAIL: CORIAN SOLID SURFACE - TYP. U.N.O. COLOR AS INDICATED.

    CORIAN COLOR SELECTIONS:CR2 - LAVA ROCK

    CHAIR RAIL NOTES:1. FIELD LAYOUT ALL CHAIR RAIL LENGTHS2. CHAIR RAIL TO WRAP COLUMNS AS SHOWN IN INTERIOR ELEVATIONS.

    CARPET TILE- CP3: 25CM X 1 M CARPET TILE. INSTALLATION METHOD: ASHLAR; VARY LOCATION OF ACCENT COLOR TO GET RANDOM PATTERN EFFECT

    CARPET COLOR: GRAY MARBLE WITH ORANGE & YELLOW LINEAR ACCENT COLORS

    RUBBER BASE: GRAPHITE COLOR, 3.2 MM THICK, 4" HIGH

    TRANSITION STRIP: SOLID VINYL REDUCER STRIP; LIGHT GRAY COLOR.

    PIPE & RADIATOR FINISHES:

    RADIATOR FINISH: TO BE PREPPED & PAINTED WHITE, SEE SPECIFICATION

    PIPE FINISH: PIPE COVERING(S) TO BE PAINTED P1

    EXST WALL

    NEW 4" BASE. SEE NOTE (1)

    NEW CARPET TILE

    EXST FLOOR

    EXST BASE

    NOTE:1. BASE APPLICATION TO MATCH EXST CONDITIONS @ ROBERTS ROOM # 301

    72

    0 S

    . Tr

    acy

    Ave

    ., B

    ozem

    an, M

    T

    dRA-

    Arc

    hite

    ct.c

    om

    dRA

    den

    nis

    Raf

    fens

    perg

    erArc

    hite

    ct

    REV. DESCRIPTION DATE

    REVIEWED BY:DRAWN BY:

    SHEET

    DATE

    SHEET TITLE

    MO

    NT

    AN

    AST

    AT

    E U

    NIV

    ER

    SIT

    Y

    MSU-CPDCMONTANA STATE UNIVERSITY

    BOZEMAN, MONTANAPHONE: 406.994.5413

    FAX: 406.994.5665

    Consultant #:1710

    CL

    ASS

    RO

    OM

    RE

    NO

    VA

    TIO

    NS

    2018

    RO

    BER

    TS H

    ALL

    31

    9 1

    00

    % C

    ON

    STR

    UC

    TIO

    N D

    RA

    WIN

    GS

    AuthorChecker

    FLOOR PLAN,REFLECTED CEILING

    PLAN, & DETAILS

    A10103/19/2018

    PR

    OJE

    CT

    #1

    PPA#18-2011

    1/4" = 1'-0"ROBERTS 319 PLAN1 1/4" = 1'-0"

    ROBERTS 319 RCP2

    1 1/2" = 1'-0" REF: 1/ A101SECTION DETAIL @ CARPET BASE3

  • P2

    RUBBER BASE

    P2

    P19'-3" DO NOT PAINT WOOD CEILING TRIM

    P1

    PROJECTION SCREEN INSTALL:FINAL LOCATION TO BE FIELD VERIFIED.VERIFY WALL TYPE AND PROVIDE APPROPRIATE ANCHOR FOR MOUNTING.

    REPLACE EXISTING WHITEBOARD SURFACE (GC TO VERIFY WHITEBOARD SURFACE DIMENSION).KEEP & REFINISH TRIM TO MATCH COLOR & FINISH @ EXST WINDOWS

    P1

    DO NOT PAINT WOOD CEILING TRIM

    EDGE OF CHAIR RAIL TO ALIGN WITH EDGE OF WINDOW

    CR2

    EDGE OF CHAIR RAIL TO ALIGN WITH EDGE OF WINDOW

    RUBBER BASE

    WOOD SILL TO BE REFINISHED TO MATCH EXST, TYP.

    METAL WINDOW SILL TO BE PAINTED P1

    RADIATOR TO BE PAINTED WHITE

    TYP: MISC PIPES TO BE PAINTED P1

    VERTICAL WIREMOLD. FINAL LOCATION TO BE FIELD VERIFIED.

    CUT CEILING TRIM @ VERTICAL WIREMOLD

    CR2

    P1

    P1

    P1

    REPLACE EXISTING WHITEBOARD SURFACE(GC TO VERIFY WHITEBOARD SURFACE DIMENSION).KEEP & REFINISH TRIM TO MATCH COLOR & FINISH @ EXST WINDOWS

    2'-1

    0"

    10"

    DO NOT PAINT WOOD CEILING TRIM

    CR2

    P1

    RUBBER BASE

    2'-1

    0"

    P1

    DO NOT PAINT WOOD CEILING TRIM

    EDGE OF CHAIR RAIL TO ALIGN WITH EDGE OF WHITEBOARD TRIM

    CR2

    RUBBER BASE

    10"

    RUBBER BASE

    REPLACE EXISTING WHITEBOARD SURFACE(GC TO VERIFY WHITEBOARD SURFACE DIMENSION).KEEP & REFINISH TRIM TO MATCH COLOR & FINISH @ EXST WINDOWS

    REPLACE GLASS IN 1/2 LITE DOOR

    10"

    3/4" SOLID SURFACE MATERIAL W/ 45 DEGREE MITER JOINT @ TOP CORNER

    3/4" PLYWD. CLEAT, GLUED TO SOLID SURF. MTL

    SET CLEAT IN CONST. ADHESIVE

    EXST WALL

    CONTIN. SEALANT JT., COLOR MATCH TO SOLID SURF. MTL.

    3/4" PLYWD. CLEAT SCREWED TO WALL

    LEGRAND STEEL WIREMOLD V700 SERIES, OR EQ.

    HUBBELL HBL5715BR TEE FITTING BEND RADIUS, OR EQ.

    HUBBELL HBL5748 STANDARD I-GANG BOX, OR EQ., W/DUAL OUTLET

    10"

    3/4" SOLID SURFACE MATERIAL W/ 45 DEGREE MITER JOINT @ TOP CORNER

    SET CLEAT IN CONST. ADHESIVE

    EXST WALL

    CONTIN. SEALANT JT., COLOR MATCH TO SOLID SURF. MTL.

    3/4" PLYWD. CLEAT SCREWED TO WALL

    LEGRAND STEEL WIREMOLD 3000 SERIES, OR EQ., CONTIN.

    3/4" PLYWD. CLEAT, GLUED TO SOLID SURF. MTL

    WALL

    SOLID SURFACE MTL

    MITER CORNER, CONT SOLID SURFACE TO WALL FACE. TYP. @ ALL ENDS OF CHAIR RAIL

    72

    0 S

    . Tr

    acy

    Ave

    ., B

    ozem

    an, M

    T

    dRA-

    Arc

    hite

    ct.c

    om

    dRA

    den

    nis

    Raf

    fens

    perg

    erArc

    hite

    ct

    REV. DESCRIPTION DATE

    REVIEWED BY:DRAWN BY:

    SHEET

    DATE

    SHEET TITLE

    MO

    NT

    AN

    AST

    AT

    E U

    NIV

    ER

    SIT

    Y

    MSU-CPDCMONTANA STATE UNIVERSITY

    BOZEMAN, MONTANAPHONE: 406.994.5413

    FAX: 406.994.5665

    Consultant #:1710

    CL

    ASS

    RO

    OM

    RE

    NO

    VA

    TIO

    NS

    2018

    RO

    BER

    TS H

    ALL

    31

    9 1

    00

    % C

    ON

    STR

    UC

    TIO

    N D

    RA

    WIN

    GS

    AuthorChecker

    ELEVATIONS

    A20003/19/2018

    PR

    OJE

    CT

    #1

    PPA#18-2011

    3/8" = 1'-0" REF: 1/ A101Elevation ROBERTS 319 WEST1

    3/8" = 1'-0" REF: 1/ A101Elevation ROBERTS 319 NORTH2

    3/8" = 1'-0" REF: 1/ A101Elevation ROBERTS 319 EAST3

    3/8" = 1'-0" REF: 1/ A101Elevation ROBERTS 319 SOUTH4

    1" = 1'-0" REF: 1/ A101CHAIR RAIL DETAIL5 1" = 1'-0"

    RACEWAY ALTERNATE CHAIR RAIL DETAIL6 1" = 1'-0" REF: 1/ A101PLAN DETAIL @ CHAIR RAIL END7

  • WAP

    S

    S

    S

    S

    J

    WAP

    J

    S

    S

    S

    S

    312A

    313A 313B

    313

    314

    315

    323

    316

    317 318 319 320

    321

    322

    306

    306B

    306C307

    312F312E312D

    312C

    312B 312

    324

    305B

    305A

    305

    304 303 302

    301

    BELOW

    OPEN TO

    DOWN

    UP

    COBLEIGH

    UP TO

    GENERAL ELECTRICAL NOTESA. ELECTRICAL DEVICES AND LIGHTS SHOWN IN GREY ARE EXISTING TO

    REMAIN. ELECTRICAL DEVICES AND LIGHTS SHOWN IN DASHED BLACK & SPECIFICALLY NOTED AS 'DEMO' ARE TO BE DEMOLISHED, UNO.

    B. IT IS ABSOLUTELY NECESSARY FOR ALL TRADES INVOLVED TO COORDINATE WITH EACH OTHER AND VERIFY THAT THERE ARE NO CONFLICTS IN LOCATION OF DUCTS, CONDUITS, DIFFUSERS, BOXES, AND OTHER ITEMS THROUGHOUT THIS PROJECT BEFORE FINAL PLACEMENT OF MATERIALS.

    C. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL CUTT