    Digital CalibrationFiberoptic Sensors

    FS-V1(P)Instruction Manual

    NPN PNP/

    075-025

    WARNING

    Accessories

    Instruction manual (x 1)

    Mounting bracket (x 1)

    Quick Reference (x 1)

    Attach this sticker closeto the FS-V1 unit.

    A B

    MODE

    SETA120PCH

    Output timer selector switch

    OFF-delay 40 ms

    ON-delay 40 ms

    Timer OFF

    Note: Outputs of both A and Bare set to the same mode.

    Calibrationindicator

    Output selector switchDARK-ON for both outputsA and B

    LIGHT-ON for output A andDARK-ON for output B

    LIGHT-ON for both outputsA and B

    Output Aindicator

    Output Bindicator

    * Use the UP/DOWN key together with the MODE selector button.

    UP/DOWN key Changes sensitivity setting value. Selects channel (expansion unit).

    PART NAMES AND FUNCTIONS

    SAFETY PRECAUTIONS

    This manual describes how to install the FS-V1(P) as well as itsoperating procedures and precautions. Please read this manualcarefully to get the best from your FS-V1(P).

    The FS-V1(P) is intended for target detection. Do not use theproduct in a safety circuit for protecting the human body.

    The FS-V1(P) is not explosion proof. Do not use the product inan environment in which inflammable gas, liquid or powder is

    present.

    MODE selector button

    Selects displayed data. Excess gain Light intensity Setting value Selects channel (expansion unit). *

    Enables/disables key protect. *

    SET buttonSets sensitivity.

    LCD display monitorTurns display red when theselected channel is ON.Turns display green when theselected channel is OFF.

    SPECIFICATIONS

    1. A "P" following the model number indicates PNP-output type.2. When several units are connected, the allowable ambient temperature changes depending

    on the following conditions. To connect several units, be sure to mount them to a DIN rail(metal DIN rail). Make sure that the output current is 20 mA. max.

    When 3 to 10 units are connected: -10 to +50 C

    When 11 to 16 units are connected: -10 to +45 C

    Model NPN output FS-V1

    PNP output FS-V1P

    Light source Red LED

    Response time 250 s

    Operation mode LIGHT-ON/DARK-ON (switch-selectable)

    Indicators Output indicators: 2 Red LEDs,

    Calibration indicator: Yellow LED,Received light intensity display: LCD (Red/Green LED back-lit)

    Timer function ON-delay: 40 ms, OFF-delay: 40 ms,

    Timer OFF (switch selectable)

    External calibration Non-voltage input (contact, solid state)

    input signal

    Control output 1. 2 outputs, NPN or PNP open-collector 100 mA max.

    (40 V max.), Residual voltage: 1 V max.

    Protection circuit Reverse polarity protection, Over-current protection,Surge absorber

    Power supply voltage 12 to 24 VDC 10%, Ripple (P-P) 10% max.Current consumption 50 mA max.

    Ambient illumination Candescent lamp: 10,000 lx max., Sunlight: 20,000 lx max.

    Ambient temperature -10 to +55C 2.

    Relative humidity 35 to 85%

    Vibration 10 to 55 Hz, 1.5 mm double amplitude in X, Y andZ directions for two hours

    Shock immunity 500 ms/s2 {Approx. 50 G} in X, Y and Z directions,three times each

    Housing material Body/Cover: Polycarbonate

    Weight Approx. 80 g (including 2 m cable)

    SELECTING DISPLAYED DATA

    s Displaying excess gain

    Received light intensity is converted by definingthe setting value as 100 P (%).

    Stable LIGHT status is obtained with 110 P (%) or more. Stable DARK status is obtained with 90 P (%) or less.

    You can adjust the sensitivity in increments of 1%. Refer to P.2.

    s Displaying received light intensity

    Received light intensity is displayed approxi-mately 4000 is the maximum setting.

    Note: The MAX and MIN values vary depending on the fiber unitconnected.

    s Displaying a setting value

    The current setting value is displayed. You can adjust the setting valuein increments of 1 . Refer to P.2.

    A120PCH

    A1234CH

    A1000CH

    MODE

    MODE MODE

    * The setting value flashes on and off.

    Excess gain (%)Received light intensity(4 digits)

    Hold down this buttonfor longer than 3 seconds.

    Press thisbutton once.

    Press thisbutton once.

    Setting value (4 digits)

    Channel display:

    Indicates the

    channel of theexpansion unit

    currently beingmonitored.

    (Factory-setting is Excess gain.)

    A120PCH

    A1234CH

    MODE

    CHSET

    UP/DOWNbuttons

    Button names:

    Two-point calibration: With a target in place,

    , and with a target removed, .

    Increasing ( ) sensitivity:[Value decreases ( ).]

    Fully-automatic calibration: Pass a targetthrough the beam while .

    MODE selector button

    SET button

    Displays receivedlight intensity

    Displays excessgain (%)

    Displays setting value (flashing)

    M

    M

    M

    M

    S

    S

    Display Switching

    Sensitivity Setting

    Fine Sensitivity Adjustment

    [Using button ]

    M

    M

    M

    [Using button ]

    [Usingor ]

    CH

    CH

    CH

    M M

    Expansion Unit Calling [Using +Using + ]

    FS-V1 Quick Reference: Press the button for just a moment.

    : Press the button for 3 seconds or more.S

    S

    While holding down , press .

    MWhile holding down , press .

    Increasing Channel No.:

    Decreasing ( ) sensitivity:[Value increases ( ).]

    Onlywhenexcessgain orsettingvalue isdisplayed.

    Only when an expansion unit(s) is connected.

    Decreasing Channel No.:

  • 8/22/2019 Keyence Fs v1 Man[1]

    2/4

    SETTING SENSITIVITY

    Select the sensitivity setting procedure according to the targetcondition.

    For sensitivity adjustment using a moving target

    q Fully-automatic Calibration

    1. Pass a target through theoptical axis while pressingthe SET button.

    2. Confirm that the calibration

    indicator (yellow LED)flashes.

    3. Release the SET button.The calibration indicator(yellow LED) goes off.

    To detect a minute difference

    q Two-point Calibration

    1. With a target in place, pressthe SET button and releaseit. The calibration indicator(yellow LED) lights.

    2. With the target removed,press the SET button andrelease it. The calibrationindicator (yellow LED) goesoff.

    For target positioning

    q Positioning Calibration

    1. With no target, press theSET button and release it.The calibration indicator(yellow LED) lights.

    2. Place a target in the positionwhere it is to be stopped.

    3. Press the SET button untilthe calibration indicatorflashes.

    4. Release the SET button.

    For stable detection unaffected by dust

    qMaximum Sensitivity Setting

    1. Under the following condi-tions press the SET button

    until the calibration indicator(yellow LED) flashes.

    2. Release the SET button.The calibration indicator(yellow LED) goes off.

    At least3 seconds

    A B

    MODE

    SETA120PCH

    At least3 seconds

    A B

    MODE

    SETA100PCH

    A B

    MODE

    SETA120PCH

    Reflect ive type Thrubeam type

    With no target With ta rget

    At least3 seconds

    CUE: When the sensitivity difference is insufficientIf sensitivity has no allowance after calibration, ------ flashes for 3seconds on the LCD display monitor.

    Note: Sensitivity is set and registered even when the sensitivitydifference is insufficient. Be sure to confirm that detection isproperly performed.

    CUE: Locking the operation button (Key protect)Hold down [MODE] and [UP] simultaneously for 3 seconds to lockthe operation button. When the operation button is locked, Loc isdisplayed in flashing letters.

    To unlock the operation button, repeat the procedure above. vnL(unlocked) is displayed in flashing letters.Even when the operation button is locked, display data and channelcan be changed.

    CHANGE THE SETTING VALUE

    You can change the setting value in excess gain display mode orsetting value display mode.

    Increase sensitivity (=Decrease the setting value)

    q In excess gain display modeThe sensitivity increases by 1% each time you press [UP].

    q In setting value display modeThe setting value decreases by 1 each time you press [DOWN].

    Decrease sensitivity (=Increase the setting value)

    The method for decreasing the sensitivity is the same as for increasingthe sensitivity, except you must press [DOWN] instead.

    CUE: Holding down [UP] or [DOWN] changes the setting valuerapidly.

    For sensitivity adjustment using an external signal

    q External Calibration Function

    1. Hold down [MODE] and [UP] simultaneously for 3 seconds todisplay Loc. (If vnl appears, repeat the same procedure.)

    2. Connect the pink cable to a switch or PLC.

    The minimum input time is 20 ms.

    3. The external calibration procedure is the same as using the SET

    button. Turn the input device on instead of pressing the SET button.Also, turn the input device off instead of releasing the SET button.(You can perform all the setting procedures described on the left.)

    MODE

    SETA120PCH

    MODE

    SETA121PCH

    MODE

    SETA 500CH

    MODE

    SETA 499CH

    MODE

    SETA120PCH

    NPN PNP

    +V

    0V

    Pink

    Blue

    Brown

    Lock

    Contact or solid state input

    +V

    0V

    Pink

    Blue

    Brown

    Lock

    Contact orsolid-state input

    CUE: Calibration input during detection

    You can re-adjust sensitivity during detection without stopping theoperation.The sensor continues operation with the previous sensitivity settinguntil sensitivity readjustment is completed.

    CUE: External calibration with several units

    When several units are connected, the sensitivity of all the FS-T2(P) expansion units can be simultaneously set using the externalcalibration input through the FS-V1(P).You can select a unit to be externally calibrated by setting its key

    protection switch to the LOCK position.External calibration is effective for all the units which are locked.Set the key protection switch to LOCK on the FS-T2(P) expansionunit to be externally calibrated.

  • 8/22/2019 Keyence Fs v1 Man[1]

    3/4

    CONTROL AN EXPANSION UNIT [FS-T2(P)]

    1. To change the channel, press[UP] (or [DOWN]) while holding[MODE].Select the channel for theexpansion unit [FS-T2(P)] to becontrolled.

    2. You can monitor the expansionunit [FS-T2(P)] or change itssensitivity setting value using thesame procedures as for the FS-

    V1(P).

    A

    B

    MODE

    SET

    A

    120P

    CH

    CH2 CH3 CH4 CH17

    Expansion units

    You cannot use the FS-V1(P)s SET button to set the sensitivity ofthe expansion unit.

    The red LED and green LED turn ON and OFF in response to theexpansion unit [FS-T2(P)] turning ON and OFF.

    Note 1: You cannot control the [FS-M2(P)] (Manual calibration model).Note 2: The channel for the [FS-M2(P)] is displayed as ------. The redLED and green LED turn ON and OFF in response to the [FS-M2(P)]turning ON and OFF.

    CONNECTING FIBER UNIT

    Lower the quick-release lever, insert the fiber unit about 14 mm until itreaches the end, and then lift the quick-release lever.

    To connect a fiber unit with a small diameter, use the adaptor

    included with the FU series.

    1. Attach the adaptor to the fiberunit.

    2. Fully insert the adaptor into themounting holes of the amplifier,and then lift the quick-releaselever.

    1 2

    1

    2

    Note: If the fiber unit is improperly connected, the sensor cannot meetthe specifications.

    The required adaptor is included in each model of the FU series. Ifan inadequate adaptor is used, the fiber unit cannot be properlyinstalled.

    To connect the coaxial reflective type fiber unit to the amplifier,connect the single-core fiber to the transmitter side, and connect themultiple-core fiber to the receiver side.(Connect the fibers according to the marking on the amplifier lateralside.)

    Adaptor A

    (OP-26500)

    Adaptor B

    (OP-26501)

    Type Shape Applicable fiber unit

    For 1.3 mm

    diameter

    For 1 mmdiameter

    FU-32/35FA/35FZ/4F/4FZ/43/63/63T/63Z/66/66Z/78/91/93

    FU-16/18/31/37/38/38V/48/59/68/75F/79/95

    MOUNTING UNIT AND SEVERAL UNITS

    s Mounting/Detaching the unit to/from a DIN rail or the

    mounting bracket.Hook the claw located at the unit cable side onto the DIN rail, and thenhook the front side claw to the rail while pressing the amplifier forward.To detach the unit, unhook the front claw by lifting the unit front sidewhile pressing it forward.

    Mounting Detaching

    s Mounting a unit laterally

    Secure the screws through the mounting brackets side hole (acces-sory)

    M3 screw

    MOUNTING UNIT AND SEVERAL UNITS

    sMounting several units

    1. Detach the protective cover from theunits side panel.

    2. Mount units to a DIN rail one by one.3. Slide one expansion unit toward

    another. Align the front claws of theunits and push the unit together untilthey click.

    4. Fix the units together by pushing anend unit onto each end. (The endunits are included in the expansionunit)

    sDetaching units from DIN rail

    1. Remove the end units.2. Slide the expansion units apart, and detach them individually.(Do not detach multiple units connected together with end units.)

    Note 1: When several units are connected, confirm the ambient temperature.(See "Specifications" on P. 1.)Note 2: To connect several units, be sure to use a DIN rail and end units.Note 3: To mount or detach several units, be sure to turn the power off.Note 4: Do not remove the protective cover of the expansion connector on theoutmost unit.

    Main unit

    Align the claw.

    Up to 16 expansion units

    can be connected.

    Remove the protective cover.

    End unit

    (Included

    with FS-T2)

    Expansionunit

    1. The FS-T1(P)/M1(P) can be used as the

    same unit as well as the FS-V1(P).

    2. FS-M2(P) can be used as the expansion unit

    as well as the FS-T2(P).

    1.2.

    Slide the unit to the

    right to remove it.

    The sticker shown on the right isincluded in the expansion unit. Applythis sticker near the sensor.

    Multiple-core Single-core

    Transmitter

    Receiver

    Channeldisplay

  • 8/22/2019 Keyence Fs v1 Man[1]

    4/4

    SETTING 2 INDEPENDENT OUTPUTS

    The FS-V1(P) allows you to set two types of sensitivity (toleranceindividually.To change the channel, press [UP] or [DOWN] while holding [MODE].

    Output lines for channels A and B

    ACH

    b

    CH

    Channel A output

    Channel B output

    Black

    White

    MUTUAL INTERFERENCE SUPPRESSION FUNCTION

    When using several fiber units, each fiber unit is free from lightinterference from up to 4 adjacent fiber units.When the fiber units are mounted closely, each fiber unit and its 4adjacent units are designed to receive light at different pulse frequen-cies to avoid interference.

    You can mount the FS-T(P) series andthe FS-M(P) series together within thesame system.

    Note: If you do not use the expansion-

    units, the mutual interference suppressfunction is not available.

    HINTS ON CORRECT USE

    To extend the cable length, use a cable with at least a 0.3 mm2

    cross-section area. Limit the length of cable extension to no morethan 100 m. (To connect several units, contact Keyence for furtherinformation.)

    If the amplifier cable is placed together with power lines or highvoltage lines in the same conduit, detection error may occur due tonoise interference, or the sensor may be damaged. Isolate theamplifier cable from these lines.

    When using a commercially available switching regulator, ground

    the frame ground terminal and ground terminal. Do not use the FS series outdoors, or in a place where extraneous

    light can enter the light receiving surface directly. During maximum sensitivity setting, the detecting distance may vary

    due to the difference in characteristics of each unit. When the stability output is not used, cut the orange cable at the

    root or connect it to the 0 V (+ for PNP output model) terminal ofthe power supply, in order to avoid contact with other cables.

    When the external calibration is not used, cut the pink cable at theroot or connect it to the + (0 V for PNP output model) terminal ofthe power supply, in order to avoid contact with other cables.

    I/O CIRCUIT

    FS-V1

    (External calibration input circuit)

    FS-V1P

    (External calibration input circuit)

    12 to 24 VDC

    Input circuit

    Load

    100mA max.

    100mA max.

    Load

    Photoelectricsensor

    maincircuit

    Overcurrent

    protectioncircuit

    Brown

    Black

    (Control output)

    White

    (Control output)

    Blue

    Pink (External calibration input)

    12 to 24 VDC

    3.3 k

    11 kPink

    0 V

    Contact or solidstate input

    12 to 24 VDC

    Input circuit

    Load

    100mA max.

    100mA max.

    Load

    Photoelectricsensor

    maincircuit

    Brown

    Black

    White

    Blue

    Pink (External calibration input)

    Overcurrent

    protectioncircuit

    3.3 k

    11 k

    0 V

    Pink12 to 24 VDC

    Contact or solidstate input

    Worldwide HeadquartersKEYENCE CORPORATION1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku,Osaka, 533-8555, JapanPHONE: 81-6-379-2211 FAX: 81-6-379-2131

    KEYENCE CORPORATION OF AMERICA

    PHONE: 201-930-0100 FAX: 201-930-0099

    KEYENCE (UK) LIMITED

    PHONE: 01908-696900 FAX: 01908-696777

    KEYENCE DEUTSCHLAND GmbH

    PHONE: 0711-797371-0 FAX: 0711-7977799

    KEYENCE FRANCE S.A.

    PHONE: 01 47 92 76 76 FAX: 01 47 92 76 77

    KEYENCE SINGAPORE PTE LTD

    PHONE: 392-1011 FAX: 392-5055

    KEYENCE (MALAYSIA) SDN BHDPHONE: 03-252-2211 FAX: 03-252-2131

    KEYENCE (THAILAND) CO., LTD

    PHONE: 02-934-6772~4 FAX: 02-934-6775

    KEYENCE KOREA CORPORATION

    PHONE: 02-563-1270 FAX: 02-563-1271

    KEYENCE CORPORATION, 1996

    F-FSV-II-9-2430 Printed in Japan

    Specifications are subject to change without notice.

    DIMENSIONS

    FS-V1(P)

    When the mounting bracket[included in FS-V1(P)] is attached:

    When several units are connected:

    Unit: mm

    1 9

    2 18

    3 27

    4 36

    5 45

    6 54

    7 63

    8 72

    9 81

    10 90

    11 99

    12 108

    13 117

    14 126

    15 135

    16 144

    No. of units L

    18

    4

    6.7 2.1

    78

    135max.

    12min.

    (Maximumwhen thecover isopened)

    3.9 5-core x

    Cable length: 2 m

    Brown/Blue: 0.34 mm2

    Black/White/Pink: 0.18 mm2

    (12.5)

    (33)

    1,1 6

    28.5

    35.48.4

    53.5

    DIN-rail mounting

    Rear view of mountingbracket

    816

    36.5

    1.1

    5

    11.3

    18.5 15

    12min.

    2 x 3,4

    2 x (4.4 x 3.4)

    15

    18

    15

    29.4

    6 18 6L

    End unit 1. End unit2.

    1. The FS-V1(P) is mounted in .2. When using expansion units, be sure to use the end unit

    (accessory to the expansions unit.)