Page 2: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

Microwave heating

A bit of theory

Page 3: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31
Page 4: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

Wavelengths range from 1mm to 1m

Frequency allowed for commercial, medical and

scientific applications:

2,450 MHz (12.2 cm wavelength)

Heating is caused by

- Dipole rotation

- Ionic migration

Theory of microwave heatingTheory of microwave heating

Page 5: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

Microwaves are not ionising radiation

Microwaves energy is largely below the energy necessary to break the bonds of common organic molecules

H-OH 5,2CH3-CH3 3,8

Hydrogen bond (water) 0,21

Chemical bond energy (eV)

Microwaves radiation (2.450 MHz) quantum energy (eV)0,0016

EnergyEnergy

Theory of microwave heatingTheory of microwave heating

Page 6: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

Interaction of materialsInteraction of materials with microwaveswith microwaves

METALS

WATER

PTFE, PP, TPX

Reflective

Absorptive

Transparent to Microwaves

Page 7: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

Metals

Water, alcohols

PTFE, PP, Cassette, WAX, Glass

• Transparent to Microwaves

Absorptive

Reflective

Interaction of materialsInteraction of materials with microwaveswith microwaves

Page 8: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

Conventional HeatingConventional Heating

The temperature of the outside surface of the

vessel is in excess of the boiling point of the solution

Container is heated first thenthen the solution.

CONDUCTIVE HEATING

SOLUTIONCONVECTIVE CURRENTS

傳導性的

Page 9: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

Microwave heatingMicrowave heating

Shorter ReactionTimes

Solution is heated firstfirst

MICROWAVE HEATING

SOLUTION

Page 10: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

Reality

• Microwaves cook my samples

• Rapid processing = poor morphology

• Antigens will be lost forever

• Molecular studies are not possible

• Day processing is useless

Microwaves create physical heat like conventionals do but internally the tissues. Better homogenity & efficiency.

Today’s technology makes 12-14hours a useless waste of time. Quality is guaranteed priority.

Diagnostic equivalence is validated by studies showing optimal antigen reactivity.

Microwave do not affect DNA, RNA and proteins’ quality at all.

Day processing = same day diagnosis = patient centric care

Perception

Page 11: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

KOSThe microwave multifunctional

tissue processor

Page 12: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31
Page 13: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

State of the Art

Microwave is switched OFF if:

1.Cavity ventilation is compromised

2.Solvent in cavity is above Threshold

3.Humidity in cavity exceeds set value

4.Microwave leak is detected

Page 14: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

In a fraction of the time

• Tissue processing

• Decalcification

• Special stains

• Gross hardening

• Fixation

•Antigen retrieval (93°C to 120°C)

KOS

Page 15: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

KOS: Smart and Fast

The first Icon driven HistoStation

Page 16: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

• Multifunctional: 1 unit 6 applications

• Fast: Just plug-in and process

• Reliable: Sensors controlled

• Flexible: User programs / Favorites

• Safe: Sensors monitored

• Smart: Icons driven

KOS*

Page 17: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

Multifunctional: ONE unit SIX major applications

• Fulfilling all requirements set by CAP/C.L.S.I.

• Ideal substitute for “kitchen type” microwave oven

• Fulfilling all requirements set by CAP/C.L.S.I.

• Ideal substitute for “kitchen type” microwave oven

Page 18: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

Rapid Tissue processingSame day results for all tissue types.

• From 1 to 45 cassettes

• Ideal for transplant center

• Urgent biopsies

• Up to 3 mm thickness

• Safe. No xylene

• Ethanol – isopropanol only

Page 19: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

Fast, unmatched tissue processing time

.

• 35 minutesFor transplant biopsies including fixation

• 75 minutesFor 2 mm biopsiesAdd 18 min fixation

• 140 minutesFor 3 mm biopsiesAdd 28 min fixation

Page 20: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

Excellent H&E, IHC and FISHIn a fraction of the time

High Quality Slides

Breast Red-Labeled HER2-FISH, x800

Colonic BiopsyH&E, x400

AdenocarcinomaCytokaratin

CAM 5.2, x400

Breast, HER2IHC, x400

Page 21: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

SMART . ICONS DRIVEN MENU

1) Select thickness.

2) Select number of cassettes.

Page 22: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

3) Select reagents

4) Press GO

Page 23: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

5) Press START.That’s all

Time left will be shown on the terminal

Page 24: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

Any protocol as Favorite

Page 25: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

Special StainsUp to 16 slides

Up to 76% time saving for staining protocols

Page 26: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31
Page 27: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

1) Select stains menu

2) Select specific stain

Page 28: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

3) Follow step by step indications

4) Selected program is prestored ready to

use.

Page 29: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

Dedicated Histomodules

4K, up to 4 cassette

45K, up to 45 cassette

16s, up to 16 slides

Page 30: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

A review of some key factors influencing the quality of sections and

stains

Page 31: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

Bench-level quality factors

• Pre-fixation• Fixation• Grossing• Processing• Embedding• Microtomy• Flotation• Section drying• H&E and special stains• IHC, ISH and FISH• Coverslipping

Page 32: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

Pre-fixation damage

“If tissue is not in a healthy, living state when it is fixed, it can reveal only abnormal details,whatever its subsequent treatment.”

Bracegirdle B. A History of Microtechnique

Page 33: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

Autolysis

Pre-fixation damage: examples

Heat damage Crush artifact

Dessication

Page 34: KOS The microwave multifunctional tissue processor 林臻鞠 友聯光學有限公司 unionopt@ms11.hinet.net 02-26980508 2013.10.31

Fixation: common problems

Inadequate volume offormalin

Poor quality fixative

Tissue fragmentsroughly handled

Inappropriate containers