  • Ultrasonic flowmetersSITRANS FUH1010 IP65 NEMA 4X & IP66 NEMA 7 Standard Volume 7ME360x-4, x=0, 3

    Operating Instructions - January 2013

    SITRANS FAnswers for industry.

  • Connecting 5.4 Flowmeter Programming

    FUH1010 IP65 NEMA 4X Std Volume 48 Operating Instructions, 01/2013, A5E02951449-AB

    6HOHFW/LTXLG&ODVVIURP/LTXLG7DEOH

    /LTXLG&ODVV :DWHU&)/LTXLG7DEOH 7DEOH$FWLYH7HPS5DQJH)WR)3LSH&RQILJ)XOO\'HYHORSHG$QRPDO\'LDPV

    $SSOLFDWLRQ'DWD

    6LHPHQV'XDO3DWK>@$%&

    Select from list.

    Select Pipe Configuration 1. Scroll down to [Pipe Config] and press the .

    2. Select a configuration that approximates the conditions upstream of your sensormounting location. (Refer to the definitions below.)

    3. Press to save selection.

    'HVLJQDWH3LSHVKDSHQHDU7UDQVGXFHUV

    $SSOLFDWLRQ'DWD

    /LTXLG&ODVV :DWHU&)/LTXLG7DEOH 7DEOH$FWLYH7HPS5DQJH)WR)

    $QRPDO\'LDPV (OERZ'EO(OERZ'EO(OERZ9DOYH([SDQGHU5HGXFHU1RUP(QWU\+HDGHU,QOHW,QWUXVLRQV

    3LSH&RQILJ)XOO\'HYHORSHG

    6LHPHQV'XDO3DWK$%&

    Use this menu cell to enter the number of pipe diameters between the upstream

    configuration and the sensor installation. Use this menu cell to select the pipe configuration that most accurately represents the

    upstream pipe condition. 4. Press the and return to the main menu.

  • Connecting 5.5 Sensor Installation

    FUH1010 IP65 NEMA 4X Std Volume Operating Instructions, 01/2013, A5E02951449-AB 49

    Table 5- 2 Pipe Configuration Option List Definitions Options Definitions

    Fully Developed Fully developed flow, as would be expected for very long straight pipe runs or installation downstream of a flow condition.

    1 Elbow Single 90 degree Elbow upstream of sensor installation. Dble Elbow+ Double out-of-plane Elbows upstream of sensor installation. Dble Elbow- Double in-plane Elbows upstream of sensor installation. Valve Not available at this time. Expander Pipe expansion upstream of sensor installation. Reducer Pipe reduction upstream of sensor installation. Norm Entry Not available at this time. Header Inlet Header or pipe manifold upstream of sensor installation. Intrusions Not available at this time.

    5.5 Sensor Installation

    5.5.1 Preliminary Installation Procedures

    Reflect and Direct Sensor Mounting Reflect and Direct mounting modes are supported for clamp-on sensors. The flow meter recommends a mounting mode after analyzing your pipe and liquid data entries.

    Note

    When installing sensors, do not key in the V/M (Version/Modification) label number as the Sensor Size.

  • Connecting 5.5 Sensor Installation

    FUH1010 IP65 NEMA 4X Std Volume 52 Operating Instructions, 01/2013, A5E02951449-AB

    iated energy.

    on

    full pipe.

    Selecting a location for the sensors 1. Locate the sensors downstream from the center of the longest available straight run. A

    location ten pipe diameters or greater downstream from the nearest bend will provideadequate flow profile conditions.

    2. Do not, if possible, install the sensors downstream from a throttling valve, a mixing tank, the discharge of a positive displacement pump or any other equipment that could possibly aerate the liquid. The best location will be as free as possible from flow disturbances, vibration, sources of heat, noise, or rad

    3. Avoid mounting the sensors on a section of pipe with any external scale. Remove allscale, rust, loose paint, etc., from the location.

    4. Do not mount the sensors on a surface aberration (pipe seam, etc.) 5. Do not mount sensors from different ultrasonic flow meters on the same pipe. Also, do

    not run the sensor cables in common bundles with cables from other instrumentation.You can run these cables through a common conduit ONLY if they originate at the sameflow meter.

    6. Never mount sensors under water, unless you order submersible units and you installthem in accordance with factory instructions.

    7. Avoid mounting sensors on the top or bottom of a horizontal pipe. The best placement on a horizontal pipe is either the ten oclock and two oclock position for Reflect Mode, or one sensor at nine oclock and one sensor at three oclock for Direct Mode. Mounting a vertical pipe is recommended only if flow is in the upward direction. When mounting ona vertical pipe flowing in a downward direction make sure there is sufficient back pressure in the system to maintain a

    R

    Dual Path, Reflect Mount Dual Path, Direct Mount Figure 5-8 Sensor Alignment (Horizontal Plane)

    Preparing the Pipe 1. Pick a mounting location with the longest straight run. You must have easy access to at

    least one side of your pipe. The pipe at the mounting location must remain full, even atzero flow.

    2. Decide on your mounting mode (Direct or Reflect). Always use Reflect Mode whenever

    possible. You may only need to use Direct Mode if your pipe is plastic.

  • Connecting 5.5 Sensor Installation

    FUH1010 IP65 NEMA 4X Std Volume Operating Instructions, 01/2013, A5E02951449-AB 53

    3. After receiving the spacing dimensions from the Installation Menu, prepare the pipesurface. De-grease the surface, if necessary, and remove any grit, corrosion, rust, loosepaint, etc. Use abrasive material provided to provide a clean contact surface for thesensors.

    Note Please note that the instructions show vertical mounting for clarity purposes only. Do not install sensors on the top of a pipe.

    Pipe Cleaned Areas Figure 5-9 Pipe Surface Preparation

    4. Clean an area 13 mm (1/2-inch) on either side of the sensors. 5. Clean an additional 13 mm (1/2-inch) along the length of the sensors.

    See also Sensor Wiring (Page 73)