Electrical data Primary nominal Type r.m.s. current I PN (A) 100 RH 100-P 200 RH 200-P 500 RH 500-P 1000 RH 1000-P V OUT Output voltage(r.m.s)@ ± I PN , R L = 10 k, T A = 25°C 4 V V C Supply voltage (± 5 %) ±15 V V d R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn > 2.5 kV I C Current consumption 10 mA R IS Isolation resistance@ 500 V DC > 500 MR L Load resistance 100 KAccuracy-Dynamic performance data e L Linearity (0 .. ± I PN ) ±0.5 % of I PN V OE Electrical offset voltage, T A = 25°C ±5 mV V OT Thermal drift of V OE ±0.3 mV/K TCe G Thermal drift of the gain (% of reading) ±0.03 %/K t r Response time @ 90% of I P 1 μs f Frequency bandwidth (±3 dB) 20Hz .. 100KHz General data T A Ambient operating temperature -10 .. +75 °C T S Ambient storage temperature -15 .. +80 °C m Mass 20 g Min. internal creepage distance/clearance ø11±0.5 mm Coreless Coil Current Transducer RH 100 .. 1000-P For the electronic measurement of currents: AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). I PN = 100 .. 1000 A Notes : 040714/1 Features No magnetic core Rogowski Coil principle Highly accurate integration circuit Voltage output Advantages Wide sensing range Wide frequency range Quick response No hysteresis error No insertion impedance Small size and lightweight Applications Observing complicated current waveforms High speed and high current sensing such as IGBT Welding Power unit Electric power regulator Discharge tube Antenna Monitoring for irruptive current LEM Components www.lem.com

Upload: aminotep

Post on 18-Nov-2015

216 views

Category:

Documents


1 download

DESCRIPTION

Coreless Coil Current Transducer

TRANSCRIPT

  • Electrical data

    Primary nominal Typer.m.s. current

    IPN (A)

    100 RH 100-P200 RH 200-P500 RH 500-P1000 RH 1000-P

    VOUT Output voltage(r.m.s)@ IPN, RL = 10 k, TA = 25C 4 VVC Supply voltage ( 5 %) 15 VVd R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn > 2.5 kVI C Current consumption 10 mARIS Isolation resistance@ 500 V DC > 500 MR L Load resistance 100 K

    Accuracy-Dynamic performance data

    L Linearity (0 .. IPN) 0.5 % of IPNVOE Electrical offset voltage, TA = 25C 5 mVVOT Thermal drift of VOE 0.3 mV/KTCG Thermal drift of the gain (% of reading) 0.03 %/Kt r Response time @ 90% of IP 1 sf Frequency bandwidth (3 dB) 20Hz .. 100KHz

    General data

    TA Ambient operating temperature -10 .. +75 CTS Ambient storage temperature -15 .. +80 Cm Mass 20 g

    Min. internal creepage distance/clearance 110.5 m m

    Coreless Coil Current TransducerRH 100 .. 1000-PFor the electronic measurement of currents: AC, pulsed, mixed, witha galvanic isolation between the primary circuit (high power) and thesecondary circuit (electronic circuit).

    IPN = 100 .. 1000 A

    Notes :

    040714/1

    Features

    No magnetic core Rogowski Coil principle Highly accurate integration circuit Voltage output

    Advantages

    Wide sensing range Wide frequency range Quick response No hysteresis error No insertion impedance Small size and lightweight

    Applications

    Observing complicated currentwaveforms

    High speed and high currentsensing such as IGBT

    Welding Power unit Electric power regulator Discharge tube Antenna Monitoring for irruptive current

    LEM Components www.lem.com

  • RH 100 .. 1000-P (in mm)

    Specifications subject to change without notice.

    M GND -Vcc+Vcc

    30

    30

    0.5

    6.3

    17.8

    20.3

    110.

    5

    6.3

    4.2

    20

    11

    4- 0.7 2-2

    52

    2-5

    Direction of Current

  • This datasheet has been download from:

    www.datasheetcatalog.com

    Datasheets for electronics components.

    http://www.datasheetcatalog.comhttp://www.datasheetcatalog.comhttp://www.datasheetcatalog.com