tango systems axcela introduction
TRANSCRIPT
Tango Systems, Inc Confidential Tango Systems, Inc Confidential
AXCELA™ 200/300/450
By
Tango Systems “Cost-Effective Metallization Solutions”
Tango Systems, Inc Confidential
What is Tango Systems? • PVD tool manufacturer incorporated in 2005 and located in San Jose, CA • PVD Technology developed in 2002 from our sister company Hionix, a thin-
film deposition company • Over 40 people with expertise in system/hardware design, source
technology, process technology and process integration • Website: www.tangosystemsinc.com
*
Leading Innovator in PVD Equipment
Manufacturing
Tango tools in Asia and USA for
production and R&D
Tango Systems, Inc Confidential
Tango’s Broad Applications
TSV
Panels
BSM
WLP
LEDs
Advanced Packaging
Thick Metal Depositions
Tango Systems, Inc Confidential
Tango: PVD Products
AXCELA
SAPPHIRE
TOPAZ
Bumping, RDL, TSV, Barrier Seed layer
Reactive & Advanced PVD
Substrates, Panels, Integrated passives
Tango Systems, Inc Confidential
Axcela: Unique Selling Points Flexible:
• Easily adaptable to any size: <150mm à 200mm à 300mm à 450mm • Productivity benefits of batch systems without the process limitations • Cluster tool for best in class process performance
Extendable Technology: • TSV, CIS, RDL, UBM and molded substrate processing
Integrated DeGas: • To eliminate contact resistance issues • Proven high vacuum transfer module • Enables good adhesion and prevents out-gassing issues
Low Temperature Processing: • Both PVD and Preclean chamber wafer platens can be cooled to -40C • Temperature in Preclean will be below 120C • Temperature in PVD will be below 150C for plated bump film stack
Tango Systems, Inc Confidential
Architectural Advantages: Tango
Lowest CoO in Industry
High Throughput
Cost of Maintenance
Low CoC
Cost of Spares
Highly Reliable
Tango Systems, Inc Confidential
AXCELA: Reliability
• MTBF: >250 hours • MTTR: <4 hours • MTBC: 5000 wafers • Up-time: >85%
Tango Systems, Inc Confidential
Key Customers • SMIC (China) • SEMCO (Korea) • Western Digital Corporation (USA) • D-Wave Systems (USA) • JCAP (China) • Unisem (China/Malaysia) • ChipMOS (Taiwan) • Nepes (Korea/Singapore)
Tango Systems, Inc Confidential Tango Systems, Inc Confidential
AXCELA™ Processes
Tango Systems, Inc Confidential Tango Systems, Inc Confidential
300 mm TiW NU = 2.26%
Tango Systems, Inc Confidential Tango Systems, Inc Confidential
300 mm Cu NU = 2.27%
Tango Systems, Inc Confidential Tango Systems, Inc Confidential
43Å Ta/Ru/Ta Film Stack 0.2% Uniformity
A Look at Tango’s Excellent Thickness & Rs Control
Tango Systems, Inc Confidential
Wafer ID : 1551-SLOT1 Test No. : 1 Test Date (M/D/Y): 06/08/2013
Notch
Contour Map Std. Dev. : 0.2077176 Contour Interval : 0.183%
8.1156108.1008668.0861238.0713808.056636 Mean8.0418928.0271488.0124057.997661
0.21% 1 sigma Rs U%
Test Date/Time 6/8/13 19:35 Mean 8.056635857 Std Devia:on (%) 0.207717597 Min 8.012399673 Max 8.096999168 Range 0.084599495
Tango Systems, Inc Confidential
Wafer ID : 1551-SLOT9 Test No. : 1 Test Date (M/D/Y): 06/08/2013
Notch
Contour Map Std. Dev. : 0.2167682 Contour Interval : 0.1695%
8.1304158.1167268.1030388.0893508.075662 Mean8.0619748.0482858.0345978.020908
0.22% 1 sigma Rs U%
Test Date/Time 6/8/13 17:32 Mean 8.075661659 Std Devia:on (%) 0.216768161 Min 8.034600258 Max 8.104200363 Range 0.069600105
Tango Systems, Inc Confidential Tango Systems, Inc Confidential
Lowest Contact Resistance
Tango Systems, Inc Confidential
Customer Contact Resistance Data
PVD1 Ti 1000+Cu 3000 unit: mΩ
PVD1 T B L R Max Ave. Min
P.1 8.62 10.00 10.86 9.20 10.86 9.24 8.45
P.2 8.46 9.74 8.45 8.62
PVD2 Ti 1000+Cu 3000 unit: mΩ
PVD2 T B L R Max Ave. Min
P.1 9.20 10.69 11.31 8.41 11.31 9.17 6.10
P.2 9.04 10.15 6.10 8.43
Tango Systems, Inc Confidential Tango Systems, Inc Confidential
10:1 Vias TSV Ti & Cu Step Coverage
Tango Systems, Inc Confidential
~15% Continuous Ti + Cu Coverage in 5x50um Vias Field = 9000A (Ti ~ 2500A; Cu ~ 6500A)
Corner, 1050Å, ~11%
Conservative measurement
Bottom, 1360Å, ~14%
Tango Systems, Inc Confidential
Demonstration of Continuous Ti/Cu Coverage in 5x50 um Vias by Conformal Cu Electroplating
Field = 9000A (Ti ~ 2500A; Cu ~ 6500A) Before Plating
Conformal Cu Plating on Wafer Pieces All the Way Down to the Via Bottom
Tango Systems, Inc Confidential
Summary/Conclusions
• Tango has shown a highly encouraging 15% continuous bottom step coverage process for high AR TSV structures – 10:1 in particular
• Ti coverages are as high as 20% for only about 2000A metal on field!
• The step coverage should be sufficient to ensure good filling by Cu electroplating - demonstrated by Cu electroplating on wafer pieces
Tango Systems, Inc Confidential Tango Systems, Inc Confidential
Efficient Batch Degassing
Tango Systems, Inc Confidential Tango Systems, Inc Confidential
Tango Degas Advantages
• Longer degas process time due to batch processing – Up to 24 wafers per Load Lock
• Enhances ICP Preclean efficiency by reaching process start pressure quickly
• Improves film adhesion • Contact resistance data from field tool running
300mm UBM TiW/Cu: – Without degas: > 30 mOhm – With degas: < 19 mOhm
Tango Systems, Inc Confidential
Efficient Degassing on Organic Substrates
Tango Systems, Inc Confidential
Thank You for Your Time
“In Step with Technology”
Tango Systems