115-130_11063346

Upload: eng13

Post on 03-Apr-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/28/2019 115-130_11063346

    1/40

    H1

    Axial Piston Pump

    Size 115/130,

    Single

    Technical

    Inormation

  • 7/28/2019 115-130_11063346

    2/40

    2 11063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Table o revisions

    Date Page Changed Rev

    30 Jul, 2009 First edition AA18 Dec, 2009 40 Japan location AB

    22 Feb, 2010 9 L15 deleted AC

    Jun, 2010 4-6, 12, 14,16, 18-19

    New EC directive BA

    Jul, 2010 30, 40 Symbol in table, new back page BB

    Sep, 2010 2, 4, 9, 14,16, 40

    Tables have been updated, page added, new back cover BC

    Feb, 2011 8 Endcap options updated BD

    Mar 2011 8-9 Model code updated BE

    Revisions

    Front cover illustrations: F301 389, P003 515

    Revision History

    Further available literatureDescription SD order number

    Overview, H1 Axial Piston Pumps, Single and Tandem L1012919

    Basic Information, H1 Axial Piston Pumps, Single and Tandem 11062168

    Technical Inormation Standard controls AC Automotive control

    H1 Axial Piston Pump, Size 045/053, Single 11063344 11076185

    H1 Axial Piston Pump, Size 045/053, Tandem 11063345 -

    H1 Axial Piston Pump, Size 060/068, Single 11071685 L1003703

    H1 Axial Piston Pump, Size 078, Single 11062169 11068353

    H1 Axial Piston Pump, Size 089/100, Single 11069970 11071849

    H1 Axial Piston Pump, Size 115/130, Single 11063346 11071850

    H1 Axial Piston Pump, Size 147/165, Single 11063347 -

    Complementary Products

    External Remote Charge Pressure Filter 11064579

    Speed and Temperature Sensor 11046759

    Pressure Sensor L1007019

    Hydraulic Fluids, Technical Inormation

    Hydraulic Fluids and Lubricants 520L0463

    Experience with Biodegradable Hydraulic Fluids 520L0465

    Design Guideline for Hydraulic Fluid Cleanliness 520L0467

    Application Inormation

    Applications Manual, Section 1, Selection of Driveline Components BLN-9885

    Applications Manual, Section 2, Pressure and Speed Limits for Hydraulic Units BLN-9884

    Applications Manual, Section 4, Transmission Circuit Recommendations BLN-9886

    PLUS+1 COMPLIANT (Electrical Installation)

    H1 Electrical Displacement Control (EDC) 11022744

    H1 3-position (FNR) Electric Control 11025001

    H1 Non-Feedback Proportional Electric (NFPE) Control 11025002

    Service Manuals

    H1 Axial Piston Pump, Size 045/053, Single 520L0958

    H1 Axial Piston Pump, Size 045/053, Tandem 520L0928

    H1 Axial Piston Pump, Size 078/115/130/147/165, Single 520L0848T000 143E

    2011 Sauer-Danfoss. All rights reserved.Sauer-Danfoss accepts no responsibility for possible errors in catalogs, brochures and other printed material. Sauer -Danfoss reserves the rightto alter its products without prior notice. This also applies to products already ordered provided that such alterations can be made withoutaecting agreed specications. All trademarks in this material are properties of their respective owners. Sauer-Danfoss, the Sauer-Danfosslogotype, the Sauer-Danfoss S-icon, PLUS+1, What really matters is inside and Know-How in Motion are trademarks of the Sauer-DanfossGroup.

  • 7/28/2019 115-130_11063346

    3/40

    311063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Content

    Technical Specications

    General TechnicalSpecications

    Dimensions

    Charge Pump

    Installation Drawings

    Technical Specifcations...............................................................................................................................4

    Shat Loads .......................................................................................................................................................6Mounting Flange Loads ...............................................................................................................................7Model Code ......................................................................................................................................................8Electrical Displacement Control (EDC) Options A2 (12 V )/A3 (24 V) ..........................................12Forward-Neutral-Reverse (FNR) Electric Control Options A9 (12 V)/B1 (24 V) .......................14Non Feedback Proportional Electric Control (NFPE) Options A8 (12 V)/B8 (24 V) ................16Manual Over Ride (MOR) ...........................................................................................................................18Displacement Limiter..................................................................................................................................19

    Input Shats ....................................................................................................................................................20Option G3, ISO 3019-1, outer dia 44 mm-4 (SAE D, 13 teeth) .................................................20Option G2, ISO 3019-1, outer dia 44 mm-4 (SAE D, 27 teeth) .................................................20

    Option F3, ISO 3019-1, Code 44-3, Diameter 44.5 taper 1:8, without key and nothrough-hole in the end o the shat ...............................................................................................21

    Auxiliary Mounting Pads............................................................................................................................22Option H2, ISO 3019-1, ange 82-2 (SAE A, 9 teeth) ..................................................................22Option H1, ISO 3019-1, ange 82-2 (SAE A, 11 teeth) ...............................................................23Option H3, ISO 3019-1, ange 101-2 (SAE B, 13 teeth) ..............................................................24Option H5, ISO 3019-1, ange 101-2 (SAE B-B, 15 teeth) .........................................................25Option S1, ISO 3019-1, ange 101-2 (SAE B, 14 teeth, special)...............................................26Option H6, ISO 3019-1, ange 127-4 (SAE C, 14 teeth) .............................................................27Option H4, ISO 3019-1, ange 152-4 (SAE D, 13 teeth) .............................................................28

    Charge Pump .................................................................................................................................................29

    Port description ............................................................................................................................................30Dimensions.....................................................................................................................................................32

    Controls ......................................................................................................................................................35Electric Displacement Control (EDC), option A2 (12 V)/A3 (24 V) ...................................35Electric Displacement Control (EDC), with manual override,optionA4 (12 V)/A5 (24 V) .............................................................................................................35Forward-Neutral-Reverse (FNR) with manual override,optionA9(12 V)/B1 (24 V) ..............................................................................................................36Non Feedback Proportional Electric control (NFPE),with manual override, option A8 (12 V)/B8 (24 V) ................................................................36

    Displacement limiters ...........................................................................................................................37Displacement limiters, option B and D.....................................................................................37

    Filtration .....................................................................................................................................................38Suction fltration, option L ............................................................................................................38Integral full ow charge pressure ltration with lter bypass sensor, option M .......39

  • 7/28/2019 115-130_11063346

    4/40

    4 11063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Technical Specifcations

    For defnitions o the ollowing specifcations, see Basic Inormation 11062168, Operating

    parameters.

    Technical Specications

    General specications

    Design Axial piston pump of cradle swashplate design with variable displacement

    Direction o rotation Clockwise, counterclockwise

    Pipe connectionsMain pressure ports: ISO split ange boss

    Remaining ports: SAE straight thread O-ring boss

    Recommended

    installation position

    Pump installation position is discretionary, however the recommended controlposition is on the top or at the side, with the top position preferred. If the pumpis installed with the control at the bottom, ushing ow must be providedthrough port M14 located on the EDC, FNR and NFPE control. Vertical inputshaft installation is acceptable. If input shaft is at the top 1 bar case pressuremust be maintained during operation.The housing must always be lled with hydraulic uid.

    Recommended mounting for a multiple pump stack is to arrange the highestpower ow towards the input source.Consult Sauer-Danfoss for nonconformance to these guidelines.

    Auxiliary cavity pressure

    Will be inlet pressure with internal charge pump. For reference see operatingparameter on next page. Will be case pressure with external charge supply.Please verify mating pump shaft seal capability.

    T000 126E

    Technical data

    Feature Unit Size 115 Size 130

    Displacement cm3 [in3] 115.2 [7.03] 130.0 [7.93]

    Flow at rated (continuous) speed l/min [US gal/min] 371 [98] 419 [111]

    Torque at maximum displace-

    ment (theoretical) Nm/bar

    [lbfin/1000psi] 1.83 [1120] 2.07 [1260]

    Mass moment of inertia of rota-ting components

    kgm2 [slugft2] 0.021 [0.0155]

    Mass [weight] dry (without auxi-liary mounting ange and lter)

    kg [lb] 83 [187]

    Oil volume liter [US gal] 2.00 [0.5]

    Mounting ange ISO 3019-1 ange 152-4 (SAE D)

    Input shat outer diameter,

    splines and tapered shats

    ISO 3019-1, outer dia 44 mm - 4 (SAE D, 13 teeth)ISO 3019-1, outer dia 44 mm - 4 (SAE D, 27 teeth)Conical keyed shaft end similar to ISO 3019-1 code 44-3, taper 1:8

    Auxiliary mounting ange with metricasteners,

    shat outer diameter and splines

    ISO 3019-1, ange 82 - 2, outer dia 16 mm - 4 (SAE A, 9 teeth)ISO 3019-1, ange 82 - 2, outer dia 19 mm - 4 (SAE A, 11 teeth)ISO 3019-1, ange 101 - 2, outer dia 22 mm - 4 (SAE B, 13 teeth)ISO 3019-1, ange 101 - 2, outer dia 25 mm - 4 (SAE B-B, 15 teeth)ISO 3019-1, ange 127 - 4, outer dia 32 mm - 4 (SAE C, 14 teeth)ISO 3019-1, ange 152 - 4, outer dia 44 mm - 4 (SAE D, 13 teeth)

    Suction port Port ISO 11926-1 1 5/8 -12 (SAE O-ring boss)

    Main port conguration 31.5 - 450 bar split ange boss per ISO 6162, M12x1.75

    Case drain ports L2, L4(SAE O-ring boss)

    Port ISO 11926-1 1 5/16 -12 (SAE O-ring boss)

    Other ports SAE O-ring boss. See installation drawings at the back o this manual.

    Customer interace threads Metric fasteners

    T000 191E

  • 7/28/2019 115-130_11063346

    5/40

    511063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Technical Specifcations

    Technical Specications

    (continued)

    Operating parameters

    Feature Unit Size 115 Size 130

    Input speed

    Minimum for internal charge supply atminimum charge pressure. Performance(pressure and displacement) may be limiteddue to limited control pressure

    min-1 (rpm)

    500

    Minimum for external charge supply at mi-nimum charge pressure. Full performance(pressure and displacement) possible at mi-nimum charge and control pressure supply

    500

    Minimum for full performance (pressure anddisplacement) for internal charge supply atminimum charge and control pressure

    1200

    Rated 3200

    Maximum 3400

    System pressure

    Maximum working pressure

    bar [psi]

    450 [6525] 420 [6090]

    Maximum pressure 480 [6960] 450 [6525]

    Maximum low loop 45 [650]

    Minimum low loop pressure 10 [145]

    Charge pressureMinimum

    bar [psi]16 [232]

    Maximum 34 [493]

    Control pressure

    Minimum (at corner power for EDC andFNR)

    bar [psi]

    17 [247]

    Minimum (at corner power for NFPE) 20 [290]

    Maximum 40 [580]

    Charge pump

    inlet pressureRated bar (absolute) [in Hg vacuum] 0.7 [9]Minimum (cold start) 0.2 [24]

    Maximum bar [psi] 4.0 [58]

    Case pressureRated

    bar [psi]3.0 [44]

    Maximum 5.0 [73]

    Lip seal external pressure Maximum bar [psi] 0.4 [5.8]T000 172E

    Fluid specications

    Feature Unit

    Viscosity

    Intermittent 1)

    mm2/s [SUS]

    5 [42]

    Minimum 7 [49]

    Recommended range 12-80 [66-370]

    Maximum 1600 [7500]

    Temperature

    range 2)

    Minimum (cold start) 3)

    C [F]

    -40 [-40]

    Recommended range 60-85 [140-185]

    Rated 104 [220]

    Maximum intermittent 1) 115 [240]

    Filtration

    (recommendedminimum)

    Cleanliness per ISO 4406 22/18/13

    Effi ciency (charge pressure ltration)-ratio

    15-20

    = 75 (10

    10)

    Effi ciency (suction and return line ltration) 35-45

    = 75 (10

    2)

    Recommended inlet screen mesh size m 100 1251) Intermittent = Short term t < 1min per incident and not exceeding 2 % of duty cycle based load-life2) At the hottest point, normally case drain port3) Cold start = Short term t < 3min, p 50 bar [725 psi], n 1000 min-1(rpm) T000 129E

    For defnitions o the ollowing specifcations, see Basic Inormation 11062168, Operating

    parameters.

  • 7/28/2019 115-130_11063346

    6/40

    6 11063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    General Technical Specifcations

    Shat Loads External radial shat loads

    H1 pumps are designed with bearings that can accept some external radial loads.The external radial shat load limits are a unction o the load position and orientation,and the operating conditions of the unit. External radial shaft loads impact lifetime.For lifetime calculations please contact Sauer-Danfoss representative.

    The maximum allowable radial load (Re) is based on the maximum external moment(Me) and the distance (L) from the mounting ange to the load. It may be determinedusing the following table and formula.

    Re = Me / L

    Me

    = Shat moment

    L = Flange distance

    Re = External force to the shaft

    Radial load position

    P003 382E

    L

    270 Re

    Re

    Me

    180 Re

    90 Re

    0 Re

    Thrust loads should be avoided. Contact factory in the event thrust loads are anticipated.

  • 7/28/2019 115-130_11063346

    7/40

    711063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    General Technical Specifcations

    Shat Loads

    (continued)

    Mounting Flange

    Loads

    All external shaft loads aect the before mentioned bearing life. In applications withexternal shaft loads, minimize the impact by positioning the load at 0 or 180 as shownin the gure.

    Contact your Sauer-Danfoss representative for an evaluation of unit bearing life.

    Sauer-Danoss recommends clamp-type couplings or applications with radial shat

    loads.

    For calculation details reer to H1 Pump Basic Inormation Manual 11062168, section

    Mounting Flange Loads.

    P001 916

    MR

    MS

    Mounting fange load

    Unit Size 115/130

    Rated moment MR

    Nm [lbfin]5933 [52 510]

    Shock load moment MS

    12 640 [111 870]

    T000 194E

    Maximum external shat load based on shat defection:

    Unit Size 115/130

    External radial moment Me

    Nm [lbfin] 129 [1140]

    T000 193E

  • 7/28/2019 115-130_11063346

    8/40

    8 11063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    General Technical Specifcations

    Displacement

    115 115.2 cm [7.03 in]

    130 130.0 cm [7.93 in]

    A Rotation

    L Left hand (counter clockwise)

    R Right hand (clockwise)

    B Product version

    B Revision code

    D Control

    A2 Electric Displacement Control (EDC) 12V, Deutsch connectorA3 Electric Displacement Control (EDC) 24V, Deutsch connector

    A4 Electric Displacement Control (EDC) 12V, Deutsch connector, Manual override

    A5 Electric Displacement Control (EDC) 24V, Deutsch connector, Manual override

    A9 Forward-Neutral-Reverse (FNR) 12V, Deutsch connector, Manual override

    B1 Forward-Neutral-Reverse (FNR) 24V, Deutsch connector, Manual override

    A8Non Feedback Proportional Electric (NFPE) 12V, Deutsch connector, Manual override(align with option E: Displacement Limiters & option W: Special Hardware)

    B8Non Feedback Proportional Electric (NFPE) 24V, Deutsch connector, Manual override(align with option E: Displacement Limiters & option W: Special Hardware)

    F Orices

    C1 Orices, 0.8 mm in servo supply 1 and 2, recommended for propel applications

    C2 Orices, 1.3 mm in servo supply 1 and 2 (Standard), recommended for propel applicationsC3 No orifce, recommended or non-propel applications

    E Displacement limiters

    N None

    C No limiters, with nested springs (required for NFPE)

    B Adjustable externally (align with option Y: Settings or adjustment, i applicable)

    DAdjustable externally with nested springs, required for NFPE(align with option Y: Settings or adjustment, i applicable)

    G Endcap options

    Twin port, ISO 6162 Split ange ports

    Matchwith belowoptions (K)

    Auxiliary mounting pad

    None,

    ISO 3019-1, ange 82 - 2 (SAE A, 9 and 11 teeth)ISO 3019-1, ange 101 - 2 (SAE B, 13 teeth)

    ISO 3019-1, ange 101 - 2 (SAE B-B, 15 teeth)ISO 3019-1, ange 127 - 4 (SAE C, 14 teeth)

    Auxiliary mounting padISO 3019-1, ange 152 - 4 (SAE D, 13 teeth)

    Matchwith belowoptions (T)

    Suctionfltration

    Integral ullcharge ow

    fltration

    Remote and externalcharge supply or ullcharge ow ltration

    Suctionfltration

    Integral ullcharge ow

    fltration

    Remote and externalcharge supply or ullcharge ow ltration

    D3 X

    D5 X

    D6 X

    D7 X

    D8 X

    D9 X

    A B D F E G H J K M N S T V W X Y

    H1 P A H

    Model Code

  • 7/28/2019 115-130_11063346

    9/40

    911063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    General Technical Specifcations

    H Mounting

    G ISO 3019-1, ange 152 - 4 (SAE D)

    J Input shat

    G3 ISO 3019-1, outer dia 44 mm - 4 (SAE D, 13 teeth splined shaft 8/16 pitch)

    G2 ISO 3019-1, outer dia 44 mm - 4 (SAE D, 27 teeth splined shaft 16/32 pitch)

    F3 Conical keyed shaft end similar to ISO 3019-1 code 44-3, taper 1:8 (key not supplied with pump)

    K Auxiliary mounting pad (align with option G: Endcap selection)

    NN None

    H2 ISO 3019-1, ange 82 - 2, outer dia 16 mm - 4 (SAE A, 9 teeth 16/32 coupling)

    Shipping cover

    H1 ISO 3019-1, ange 82 - 2, outer dia 19 mm - 4 (SAE A, 11 teeth 16/32 coupling)

    H3 ISO 3019-1, ange 101 - 2, outer dia 22 mm - 4 (SAE B, 13 teeth 16/32 coupling)H5 ISO 3019-1, ange 101 - 2, outer dia 25 mm - 4 (SAE B-B, 15 teeth 16/32 coupling)

    S1 ISO 3019-1, ange 101 - 2, outer dia 22 mm - 4 (SAE B, 14 teeth 12/24 coupling)

    H6 ISO 3019-1, ange 127 - 4, outer dia 32 mm - 4 (SAE C, 14 teeth 12/24 coupling)

    H4 ISO 3019-1, ange 152 - 4, outer dia 44 mm - 4 (SAE D, 13 teeth 8/16 coupling)

    M Overpressure protection type and setting side A **

    N Overpressure protection type and setting side B **** Pressure protection type must be the same or side A and B

    LHigh pressure relief valve + pressurelimiters with bypass

    Use the selection for ports A and B

    KHigh pressure relief valve with bypass

    (no pressure limiters)L20 K20 200 bar [2900 psi]

    L23 K23 230 bar [3336 psi]

    L25 K25 250 bar [3630 psi]

    L28 K28 280 bar [4061 psi]

    L30 K30 300 bar [4350 psi]

    L33 K33 330 bar [4786 psi]

    L35 K35 350 bar [5080 psi]

    L38 K38 380 bar [5510 psi]

    L40 K40 400 bar [5800 psi]

    L42 K42 420 bar [6090 psi]

    L43 430 bar [6237 psi] (115 cm3 only)

    L44 440 bar [6382 psi] (115 cm3 only)

    L45 K45 450 bar [6960 psi] (115 cm3 only)

    Contact factory for pressures not shown or for applied pressure above rated (see System Pressure page 5)

    S Charge pump

    A 26 cm/rev [1.59 in/rev]

    L 34 cm/rev [2.07 in/rev]

    N No charge pump, external charge supply, (align with Option T: Filtration Options, option E)

    Model Code

    (continued)

    A B D F E G H J K M N S T V W X Y

    H1 P N N N N N N

  • 7/28/2019 115-130_11063346

    10/40

    10 11063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    General Technical Specifcations

    T Filtration options (align with option G: Endcap selection)

    L Suction fltration (see basic drawings)

    MIntegral full charge ow ltration with bypass sensor and bypass sensor,long lter, order number 11004919

    P Remote full charge ow ltration (see endcap drawings)

    E External charge ow ltration (see endcap drawings), (align with option S: Charge pump, option N)

    V Charge pressure relie setting

    20 20 bar [290 psi]

    24 24 bar [348 psi]

    30 30 bar [435 psi]

    W Special hardware eatures

    NN None

    M1 NFPE valve plate (align with option D: Control selection and option E: Displacement limiters)

    X Paint and nametag

    NNN Black paint and Sauer-Danfoss nametag

    Y Special settings

    NNN None

    Model Code

    (continued)

    A B D F E G H J K M N S T V W X Y

    H1 P N N N N N N

  • 7/28/2019 115-130_11063346

    11/40

    1111063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Notes

    Notes

  • 7/28/2019 115-130_11063346

    12/40

    12 11063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    General Technical Specifcations

    Electrical Displacement

    Control (EDC)

    OptionsA2 (12 V)/A3 (24 V)

    P003 479E

    "0"

    -b -a

    ba

    100 %

    100 %

    Displacement

    Current mA

    Control signal requirements

    Pump displacement vs. control current

    Feedback fromSwash plate

    PTF00B

    M14

    C1 C2

    F00A

    P003 478E

    EDC-Schematic diagram

    P003 191

    1 2

    P003 480

    Connector

    EDC Principle

    The Electrical Displacement Control

    (EDC) consists of a pair of proportionalsolenoids on each side o a three-

    position, four-way porting spool. Theproportional solenoid applies a orce

    input to the spool, which ports hydraulic

    pressure to either side of a double actingservo piston. Dierential pressure acrossthe servo piston rotates the swashplate,changing the pumps displacement rom

    ull displacement in one direction to ull

    displacement in the opposite direction.

    Under some circumstances, such ascontamination, the control spool could

    stick and cause the pump to stay at somedisplacement.

    A serviceable 125 m screen is located inthe supply line immediately before thecontrol porting spool.

    Control current

    Voltagea*

    mA

    b

    mA

    Pin

    connections

    12 V 640 1640any order

    24 V 330 820

    * Factory test current, for vehicle movement or

    application actuation expect higher or lower value.T000133E

    Description Quantity Ordering number

    Mating connector 1 Deutsch DT06-2S

    Wedge lock 1 Deutsch W2S

    Socket contact (16 and 18 AWG) 2 Deutsch 0462-201-16141

    Sauer-Danfoss mating connector kit 1 K29657T000 134E

  • 7/28/2019 115-130_11063346

    13/40

    1311063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    General Technical Specifcations

    Electrical Displacement

    Control (EDC)

    OptionsA2 (12 V)/A3 (24 V)

    (continued)

    Control response

    H1 controls are available with optional control passage orices to assist in matchingthe rate of swashplate response to the application requirements (e.g. in the event ofelectrical failure). Software ramp or rate limiting should be used to control vehicleresponse in normal operation. The time required for the pump output ow to changefrom zero to full ow (acceleration) or full ow to zero (deceleration) is a net function ofspool porting, orices, and charge pressure. A swashplate response table is availablefor each frame indicating available swashplate response times. Testing should beconducted to verify the proper software and orice selection for the desired response.

    H1 pumps are limited in mechanical oricing combinations. Software is envisionedas the means to control the swashplate response in normal operating conditions.Mechanical servo orices are to be used only for fail-safe return to neutral in the event ofan electrical failure.

    Typical response times shown below at the following conditions:

    p = 250 bar [3626 psi]

    Viscosity and temperature = 30 mm2/s (50 C) [141 SUS (122 F)]Charge pressure = 20 bar [290 psi]

    Speed = 1800 min-1 (rpm)

    Flow table

    Shat rotation CW CCWCoil energized* C2 C1 C2 C1

    Port A in out out in

    Port B out in in out

    Servo port pressurized M5 M4 M5 M4

    * For coil location see installation drawings. T000 136E

    Solenoid data

    Voltage 12V 24V

    Maximum current 1800 mA 920 mA

    Coil resistance @ 20 C [70 F] 3.66 14.20

    Coil resistance @ 80 C [176 F] 4.52 17.52

    PWM Range 70-200 Hz

    PWM Frequency (preferred)* 100 Hz

    Inductance 33 mH 140 mH

    IP Rating (IEC 60 529) + DIN 40 050, part 9 IP 67

    IP Rating (IEC 60 529) + DIN 40 050, part 9with mating connector

    IP 69K

    * PWM signal required for optimum control performance. T000 135E

    Response times

    Stroking direction 0.8 mm [0.03 in] Orice 1.3 mm [0.05 in] Orice No orice

    Neutral to full ow 4.4 s 1.9 s 1.0 s

    Full ow to neutral 2.9 s 1.3 s 0.8 sT000 195E

  • 7/28/2019 115-130_11063346

    14/40

    14 11063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    General Technical Specifcations

    Forward-Neutral-Reverse

    (FNR) Electric Control

    OptionsA9 (12 V)/B1 (24 V)

    The 3-Position (F-N-R) control uses anelectric input signal to switch the pump

    to a full stroke position.

    Under some circumstances, such ascontamination, the control spool could

    stick and cause the pump to stay at somedisplacement.

    A serviceable 125 m screen is located inthe supply line immediately before thecontrol porting spool.

    Solenoid connector

    1 2

    P003 480

    3-Position electric control,

    hydraulic schematic

    P003 190E

    100 %

    0

    100 %

    Voltage VDC

    Displacement

    Pump displacement vs. electrical signal

    P003 193

    P003 189

    C2C1

    F00A

    M14

    T PF00B

    Control current

    Voltage

    Min. current to

    stroke pump

    mA

    Pin

    connections

    12 V 750any order

    24 V 380T000 138E

    Description Quantity Ordering number

    Mating connector 1 Deutsch DT06-2S

    Wedge lock 1 Deutsch W2S

    Socket contact (16 and 18 AWG) 2 Deutsch 0462-201-16141

    Sauer-Danfoss mating connector kit 1 K29657T000 134E

  • 7/28/2019 115-130_11063346

    15/40

    1511063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    General Technical Specifcations

    Forward-Neutral-Reverse

    (FNR) Electric Control

    OptionsA9 (12 V)/B1 (24 V)

    (continued)

    Control response

    H1 controls are available with optional control passage orices to assist in matchingthe rate of swashplate response to the application requirements (e.g. in the event ofelectrical failure). Software ramp or rate limiting should be used to control vehicleresponse in normal operation. The time required for the pump output ow to changefrom zero to full ow (acceleration) or full ow to zero (deceleration) is a net function ofspool porting, orices, and charge pressure. A swashplate response table is availablefor each frame indicating available swashplate response times. Testing should beconducted to verify the proper software and orice selection for the desired response.

    H1 pumps are limited in mechanical oricing combinations. Software is envisionedas the means to control the swashplate response in normal operating conditions.Mechanical servo orices are to be used only for fail-safe return to neutral in the event ofan electrical failure.

    Typical response times shown below at the following conditions:

    p = 250 bar [3626 psi]

    Viscosity and temperature = 30 mm2/s (50 C) [141 SUS (122 F)]Charge pressure = 20 bar [290 psi]

    Speed = 1800 min-1 (rpm)

    Pump output fow direction vs. control signal

    Shat rotation CW CCWCoil energized* C1 C2 C1 C2

    Port A in out out in

    Port B out in in out

    Servo port pressurized M5 M4 M5 M4

    * For coil location see installation drawings. T000 140E

    Solenoid data

    Voltage 12 V 24 V

    Minimum supply voltage 9.5 Vdc 19.0 Vdc

    Maximum supply voltage (continuous) 14.6 Vdc 27.0 Vdc

    Maximum current 1050 mA 500 mA

    Nominal coil resistance @ 20 C [70 F] 8.4 34.5

    PWM Range 70-200 Hz

    PWM Frequency (preferred)* 100 Hz

    IP Rating (IEC 60 529) + DIN 40 050, part 9 IP 67

    IP Rating (IEC 60 529) + DIN 40 050, part 9with mating connector

    IP 69K

    * PWM signal required for optimum control performance. T000 139E

    Response times

    Stroking direction 0.8 mm [0.03 in] Orice 1.3 mm [0.05 in] Orice No orice

    Neutral to full ow 4.2 s 1.9 s 1.2 s

    Full ow to neutral 5.2 s 2.2 s 1.1 sT000 196E

  • 7/28/2019 115-130_11063346

    16/40

    16 11063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    General Technical Specifcations

    Non Feedback

    Proportional Electric

    Control (NFPE)Options

    A8 (12 V)/B8 (24 V)

    The Non Feedback Proportional Electric(NFPE) control is an electrical automotivecontrol in which an electrical inputsignal activates one of two proportionalsolenoids that port charge pressure to

    either side of the pump servo cylinder.The NFPE control has no mechanicalfeedback mechanism.

    The pump displacement is proportional

    to the solenoid signal current, but it alsodepends upon pump input speed and

    system pressure. This characteristic alsoprovides a power limiting function by

    reducing the pump swashplate angleas system pressure increases. A typicalresponse characteristic is shown in the

    accompanying graph.

    Under some circumstances, such ascontamination, the control spool could

    stick and cause the pump to stay at somedisplacement.

    A serviceable 125 m screen is located inthe supply line immediately before thecontrol porting spool.

    P003 188

    C2C1

    F00A

    M14

    T PF00B

    NFPE Schematic

    P003 192

    Control signal requirements

    "0"

    Signal Current

    mA(DC)

    a b c

    abc

    Displacemen

    t

    100 %

    100 %

    NFPE control

    p

    =3

    00b

    ar

    p

    =3

    00b

    ar

    p

    =0

    bar

    p

    =0

    bar

    P003 187E

    Pump displacement vs. input signal

    1 2

    P003 480

    Connector

    Control current

    Voltagea*

    mA

    b

    mA

    c

    mA

    Pin

    connections

    12 V 870 1290 1540any order

    24 V 440 670 770

    * Factory test current, for vehicle movement or

    application actuation expect higher or lower value.T301 049E

    Description Quantity Ordering number

    Mating connector 1 Deutsch DT06-2S

    Wedge lock 1 Deutsch W2S

    Socket contact (16 and 18 AWG) 2 Deutsch 0462-201-16141

    Sauer-Danfoss mating connector kit 1 K29657

    T000 134E

  • 7/28/2019 115-130_11063346

    17/40

    1711063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    General Technical Specifcations

    Non Feedback

    Proportional Electric

    Control (NFPE)Options

    A8 (12 V)/B8 (24 V)

    (continued)

    Control response

    H1 controls are available with optional control passage orices to assist in matchingthe rate of swashplate response to the application requirements (e.g. in the event ofelectrical failure). Software ramp or rate limiting should be used to control vehicleresponse in normal operation. The time required for the pump output ow to changefrom zero to full ow (acceleration) or full ow to zero (deceleration) is a net function ofspool porting, orices, and charge pressure. A swashplate response table is availablefor each frame indicating available swashplate response times. Testing should beconducted to verify the proper software and orice selection for the desired response.

    H1 pumps are limited in mechanical oricing combinations. Software is envisionedas the means to control the swashplate response in normal operating conditions.Mechanical servo orices are to be used only for fail-safe return to neutral in the event ofan electrical failure.

    Typical response times shown below at the following conditions:

    p = 250 bar [3626 psi]

    Viscosity and temperature = 30 mm2/s (50 C) [141 SUS (122 F)]Charge pressure = 20 bar [290 psi]

    Speed = 1800 min-1 (rpm)

    Pump output fow direction vs. control signal

    Shat rotation CW CCWCoil energized* C1 C2 C1 C2

    Port A in out out in

    Port B out in in out

    Servo port pressurized M5 M4 M5 M4

    * For coil location see installation drawings. T000 140E

    Response times

    Stroking direction 0.8 mm [0.03 in] Orice 1.3 mm [0.05 in] Orice No orice

    Neutral to full ow 5.1 s 2.5 s 1.5 s

    Full ow to neutral 3.2 s 1.4 s 0.7 sT000 197E

    istance @ 80 C [176 F] 4.52 17.52

    ange 70-200 Hz

    requency (preferred)* 100 Hz

    nce 33 mH 140 mH

    g (IEC 60 529) + DIN 40 050, part 9 IP 67

    g (IEC 60 529) + DIN 40 050, part 9ating connector

    IP 69K

    signal required for optimum control performance. T000 135E

  • 7/28/2019 115-130_11063346

    18/40

    18 11063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    General Technical Specifcations

    Manual Over Ride (MOR)

    Feedback from

    Swash plate

    PTF00B

    M14

    C2C1

    F00A

    P003 205E

    MOR-Schematic diagram (EDC shown)

    P003 204

    All controls are available with a Manual Over Ride (MOR) either standard or as an optionfor temporary actuation of the control to aid in diagnostics.

    Forward-Neutral-Reverse (FNR) and Non Feedback Proportional Electric (NFPE) controlsare always supplied with MOR functionality.

    Unintended MOR operation will cause the pump to go into stroke. The vehicle or devicemust always be in a safe condition (i.e. vehicle lifted o the ground) when using theMOR function. The MOR plunger has a 4 mm diameter and must be manually depressedto be engaged. Depressing the plunger mechanically moves the control spool whichallows the pump to go on stroke. The MOR should be engaged anticipating a full strokeresponse from the pump.

    WarningAn o-ring seal is used to seal the MOR plunger where initial actuation of the function will

    require a force of 45 N to engage the plunger. Additional actuations typically requireless force to engage the MOR plunger. Proportional control of the pump using the MORshould not be expected.

    Refer to control owtable for the relationship of solenoid to direction of ow.

  • 7/28/2019 115-130_11063346

    19/40

    1911063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    General Technical Specifcations

    Displacement Limiter H1 pumps are designed with optional mechanical displacement (stroke) limitersfactory set to max. displacement.

    The maximum displacement of the pump can be set independently for forward andreverse using the two adjustment screws to mechanically limit the travel of the servopiston down to 50 % displacement. Adjustment procedures are found in the H1 pumpsService Manual.

    Adjustments under operating conditions may cause leakage. The adjustment screw canbe completely removed from the threaded bore if backed out to far.

    Displacement limiter

    P003 266

    For more inormation reer to H1 pumps Service Manual 520L0848, section Displacement

    Limiter Adjustment.

    Displacement change (approximately)

    Size1 Turn o displacement

    limiter screw

    Internal

    wrench size

    External

    wrench size

    Torque or external

    hex seal lock nut

    115 10.8 cm3 [0.66 in3]6 mm 22 mm 80 Nm [708 lbfin]

    130 12.2 cm3 [0.74 in3]T000 198E

  • 7/28/2019 115-130_11063346

    20/40

    20 11063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Dimensions

    Input Shats Option G3, ISO 3019-1, outer dia 44 mm-4 (SAE D, 13 teeth)

    Option G2, ISO 3019-1, outer dia 44 mm-4 (SAE D, 27 teeth)

    P003 384E

    8.05 0.8

    [0.317 0.031]

    12.45 0.25[0.49 0.01]

    39.5 1.0[1.555 0.039]

    67.0 1.0[2.638 0.039]

    36.4

    0.1

    3

    [1.4

    33

    0.0

    5]

    44

    .356

    0.0

    9

    [1.7

    46

    0.0

    04]

    152.4

    0

    0.0

    5

    [6.0

    00

    0

    0.0

    02

    ]

    Coupling must not

    protrude beyondthis Point

    R 0.8 max.[0.031]

    Mounting flange surfaceFlange 152 - 4 per ISO 3019-1to be paint free

    Spline data

    Number of teeth : 13Pitch fraction : 8/16Pressure angle : 30Pitch- : 41.275 [1.625]

    Typ of fit : Fillet root sideper : Ansi B92.1-1996 class 5

    8.05 0.8[0.317 0.031]

    P003 385E12.45 0.25

    [0.49 0.01]

    42.0 1.0[1.654 0.039]

    67.0 1.0[2.638 0.039]

    39.5

    0.1

    3

    [1.5

    55

    0.0

    5]

    44.3

    6

    0.0

    9

    [1.7

    46

    0.0

    04]

    152.4

    0

    0.0

    5

    [6.0

    00

    0

    0.0

    02

    ]

    R 0.8 max.[0.031]

    Mounting flange surface

    Flange 152 - 4 per ISO 3019-1to be paint free Spline data

    Number of teeth : 27Pitch fraction : 16/32Pressure angle : 30Pitch- : 42.863 [1.688]

    Typ of fit : Fillet root sideper : Ansi B92.1-1996 class 5

    Coupling must not

    protrude beyondthis Point

    Specications

    Option Spline

    Min active spline

    length2Torque rating1

    Rated torque Maximum torque

    mm [in] Nm [lbfin] Nm [lbfin]

    G3 13 teeth, 8/16 pitch 39.5 [1.555] 1442 [12 800] 2206 [19 500]1) For denitions of maximum and rated torque values, refer to:

    Basic Inormation Manual 11062168, section Shat Torque Ratings and Spline Lubrication.2) Minimum active spline length for the specied torque ratings. T000 200E

    Specications

    Option Spline

    Min active spline

    length2Torque rating1

    Rated torque Maximum torque

    mm [in] Nm [lbfin] Nm [lbfin]

    G2 27 teeth, 16/32 pitch 42.0 [1.654] 1615 [14 300] 3000 [26 550]1) For denitions of maximum and rated torque values, refer to:

    Basic Inormation Manual 11062168, section Shat Torque Ratings and Spline Lubrication.2)

    Minimum active spline length for the specied torque ratings. T000 201E

    mm

    [in]

  • 7/28/2019 115-130_11063346

    21/40

    2111063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Dimensions

    Option F3, ISO 3019-1, Code 44-3, Diameter 44.5 taper 1:8, without key and no

    through-hole in the end o the shat

    P003 520E8.025 0.8

    [0.361 0.31]

    93.7 1.0[3.689 0.039]

    39.7 1.0[1.563 0.039]

    125 0.5 : 1000

    (54.0)[2.126]

    44.4

    5

    [1.7

    50]

    Coupling must notoverlap till this point

    Shafts

    to be paint free

    Conical keyed shaft end

    similar to ISO 3019-1 code 38-3

    Suitable key 7/16 x 7/16 x 1 3/4

    ANSI B17.1

    11

    /4

    -12

    12.45 0.25[0.49 0.01]

    152.0

    0

    0.0

    5

    [6.0

    00

    0

    0.0

    02

    ]

    Mounting flange surface

    Flange 152 - 4 per ISO 3019-1to be paint free

    Input Shats

    (continued)

    Tapered shat customer acknowledgement

    The Sauer-Danfoss H1 tapered shaft has been designed using the industry standard ISO3019-1, minus the through-hole in the end of the shaft. Sauer-Danfoss recommends aself-locking nut instead of a castle nut and pin. The nut and mating square-cut key arecustomer supplied.

    The specied torque rating of the tapered shaft documented above is based on thecross-sectional diameter of the shaft, through the keyway, and assumes the properclamp and t between shaft and coupling. Sauer-Danfoss guarantees the design and

    manufactured quality of the tapered shaft. The customer is responsible for the designand manufactured quality of the mating female coupling and key and applied torque onthe nut.

    Sauer-Danfoss has made provisions for the key in accordance to the ISO specicationwith the understanding that the key is solely to assist in the installation of the matingcoupling.

    CCaution

    Torque must be transmitted by the taper t between the shaft and its mating coupling,not the key. Torque or loading inadvertently transmitted by the customer supplied keymay lead to premature shaft failure.

    Specications

    Option Tapered shat

    Torque rating1)

    Rated torque* Maximum torque

    Nm [lfbin] Nm [lfbin]

    F3 44-3 taper without key 2) 1766 [15 630] 2354 [20 830]1) For denitions of maximum and rated torque values, refer to: Basic Inormation Manual 11062168, section Shat Torque Ratings and Spline Lubrication.2)

    Mating part must maintain a minimum gap width of 1.0 mm with the shaft shoulder after installation of thepart. Transmittable torque will be reduced if the minimum gap requirement is not met.* Rated torque includes just the capability of the press-t in accordance with an assumed fastener grade 5.

    T000 202E

    mm[in]

  • 7/28/2019 115-130_11063346

    22/40

    22 11063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Dimensions

    Auxiliary Mounting Pads Option H2, ISO 3019-1, fange 82-2 (SAE A, 9 teeth)

    P003 386E

    2x 106.4 0.35

    [4.189 0.014]

    8.1 0.25

    [0.319 0.010]

    329.857 2.0

    [12.986 0.079]

    314.73 2.0

    [12.391 0.079]

    4x 53.2 0.175

    [2.094 0.007]

    88.6

    21

    +0.1

    3

    0

    [3.4

    89

    +0.0

    5

    0

    ]

    82.6

    01

    +0.0

    76

    0

    [3.2

    52

    +0.0

    03

    0

    ]

    15.3 + 1.0 0

    [0.602 + 0.039 0

    ]

    1.956

    [0.077]

    R 0.8 max.

    [0.031]

    Thread : M10x1.5-6H THD

    Depth : 16.0 [0.63] min.4x

    O-ring seal required

    ref 82.22 [3.237] I.D.x 2.62 [0.103] cross section

    Spline data

    Number of teeth : 9Pitch fraction : 16/32Pressure angle : 30Pitch- : 14.288 [0.5625]

    Typ of fit : Fillet root sideper : Ansi B92.1-1996 class 6

    Mounting flange surface

    Flange 82 - 2 per ISO 3019-1to be paint free

    C Caution

    Standard pad cover is installed only to retain coupling during shipping. Do not operatepump without an auxiliary pump or running cover installed.

    Specications

    Option Spline

    Torque rating1

    maximum torque

    Nm [lbfin]

    H2 9 teeth, 16/32 pitch 162 [1430]1) For denitions of maximum torque values, refer to:

    Basic Inormation Manual 11062168, section Shat Torque Ratings and Spline Lubrication. T000 150E

    mm

    [in]

  • 7/28/2019 115-130_11063346

    23/40

    2311063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Dimensions

    Auxiliary Mounting Pads

    (continued)

    Option H1, ISO 3019-1, fange 82-2 (SAE A, 11 teeth)

    P003 387E

    2x 106.4 0.35

    [4.189 0.014]

    8.1 0.25

    [0.319 0.010]

    329.857 2.0

    [12.986 0.079]

    314.73 2.0

    [12.391 0.079]

    4x 53.2 0.175

    [2.094 0.007]

    88.6

    21

    +0.1

    3

    0

    [3.4

    89

    +0.0

    5

    0

    ]

    82.6

    01

    +0.0

    76

    0

    [3.2

    52

    +0.0

    03

    0

    ]

    25.3 + 1.0 0

    [0.996 + 0.039 0

    ]

    1.956

    [0.077]

    R 0.8 max.[0.031]

    O-ring seal required

    ref 82.22 [3.237] I.D.x 2.62 [0.103] cross section

    Mounting flange surface

    Flange 82 - 2 per ISO 3019-1to be paint free

    Thread : M10x1.5-6H THD

    Depth : 16.0 [0.63] min.4x

    Spline data

    Number of teeth : 11Pitch fraction : 16/32Pressure angle : 30Pitch- : 17.463 [0.6875]

    Typ of fit : Fillet root sideper : Ansi B92.1-1996 class 6

    C Caution

    Standard pad cover is installed only to retain coupling during shipping. Do not operatepump without an auxiliary pump or running cover installed.

    Specications

    Option Spline

    Torque rating1

    maximum torque

    Nm [lbfin]

    H1 11 teeth, 16/32 pitch 296 [2620]1) For denitions of maximum torque values, refer to:

    Basic Inormation Manual 11062168, section Shat Torque Ratings and Spline Lubrication. T000 151E

    mm

    [in]

  • 7/28/2019 115-130_11063346

    24/40

    24 11063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Dimensions

    Auxiliary Mounting Pads

    (continued)

    C Caution

    Standard pad cover is installed only to retain coupling during shipping. Do not operatepump without an auxiliary pump or running cover installed.

    Specications

    Option Spline

    Torque rating1

    maximum torque

    Nm [lbfin]

    H3 13 teeth, 16/32 pitch 395 [3500]1) For denitions of maximum torque values, refer to:

    Basic Inormation Manual 11062168, section Shat Torque Ratings and Spline Lubrication. T000 152E

    Option H3, ISO 3019-1, fange 101-2 (SAE B, 13 teeth)

    P003 388E

    2x 146.0 0.35

    [5.748 0.014]

    11.4 0.25

    [0.449 0.010]

    330.386 2.0

    [13.007 0.079]

    314.73 2.0

    [12.391 0.079]

    4x 73.0 0.175

    [2.874 0.007]

    107.8

    23

    +0

    .13

    0

    [4.2

    45

    +0.

    05

    0

    ]

    101.6

    51

    +0.0

    76

    0

    [4.0

    02

    +0.0

    03

    0

    ]

    20.3 + 1.0 0

    [0.799 + 0.039 0

    ]

    1.956

    [0.077]

    Thread : M12x1.75-6H THD

    Depth : 25.0 [0.984] min.4x

    Spline data

    Number of teeth : 13Pitch fraction : 16/32Pressure angle : 30Pitch- : 20.638 [0.813]

    Typ of fit : Fillet root sideper : Ansi B92.1-1996 class 6

    O-ring seal required

    ref 94.92 [3.737] I.D.x 2.62 [0.103] cross section

    R 0.8 max.

    [0.031]

    Mounting flange surface

    Flange 101 - 2 per ISO 3019-1to be paint free

    mm

    [in]

  • 7/28/2019 115-130_11063346

    25/40

    2511063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Dimensions

    Auxiliary Mounting Pads

    (continued)

    C Caution

    Standard pad cover is installed only to retain coupling during shipping. Do not operatepump without an auxiliary pump or running cover installed.

    Specications

    Option Spline

    Torque rating1

    maximum torque

    Nm [lbfin]

    H5 15 teeth, 16/32 pitch 693 [6130]1) For denitions of maximum torque values, refer to:

    Basic Inormation Manual 11062168, section Shat Torque Ratings and Spline Lubrication. T000 153E

    Option H5, ISO 3019-1, fange 101-2 (SAE B-B, 15 teeth)

    P003 389E

    330.386 2.0

    [13.007 0.079]

    314.73 2.0

    [12.391 0.079]

    25.3 + 1.0 0

    [0.996 + 0.039 0

    ]

    Mounting flange surface

    Flange 101 - 2 per ISO 3019-1to be paint free

    107.8

    23

    +0.1

    3

    0

    [4.2

    45

    +0.0

    5

    0

    ]

    101.6

    51

    +0.0

    76

    0

    [4.0

    02

    +0.0

    03

    0

    ]

    2x 146.0 0.35[5.748 0.014]

    4x 73.0 0.175[2.874 0.007]

    Thread : M12x1.75-6H THD

    Depth : 25.0 [0.984] min.4x

    11.4 0.25[0.449 0.010]

    1.956[0.077]

    O-ring seal required

    ref 94.92 [3.737] I.D.x 2.62 [0.103] cross section

    R 0.8 max.

    [0.031]

    Spline data

    Number of teeth : 15Pitch fraction : 16/32Pressure angle : 30Pitch- : 23.813 [0.938]

    Typ of fit : Fillet root sideper : Ansi B92.1-1996 class 6

    mm

    [in]

  • 7/28/2019 115-130_11063346

    26/40

    26 11063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Dimensions

    Auxiliary Mounting Pads

    (continued)

    C Caution

    Standard pad cover is installed only to retain coupling during shipping. Do not operatepump without an auxiliary pump or running cover installed.

    Specications

    Option Spline

    Torque rating1

    maximum torque

    Nm [lbfin]

    H6 14 teeth, 12/24 pitch 816 [7220]1) For denitions of maximum torque values, refer to:

    Basic Inormation Manual 11062168, section Shat Torque Ratings and Spline Lubrication. T000 154E

    Option S1, ISO 3019-1, fange 101-2 (SAE B, 14 teeth, special)

    O-RING SEAL REQUIREDREF 101.32 [ 3.989] ID X2.62 [.103] CROSS SECTION

    SPLINE DATANUMBER OF TEETH : 14PITCH FRACTION : 12/24PRESSURE ANGLE : 30PITCH- :29.633 [1.167]

    TYP OF FIT : FILLETT ROOT, SIDE FITPER : ANSI B92.1-1996 CLASS 6MIN ACTIVE SPLINE LENGTH 17.8MM

    1.96[0.077]

    11.4 0.25[0.449 0.010]

    MOUNTING FLANGE SURFACEFLANGE 101 - 2 PER ISO 3019-1

    TO BE PAINT FREE

    R0.8 MAX[0.031]

    +0.0

    03

    -0.0

    00

    101.

    65

    [4.0

    02]

    +0.0

    76

    -0

    +0.0

    05

    -0.0

    00

    1

    07.8

    2

    [4.2

    45]

    +0.1

    3

    -0

    +0.039-0.000

    19[0.748]

    +1-0

    71.48[2.814]

    AUXILARY PUMPSHAFT LENGHT

    314.73 2[12.391 0.079]

    330.386 2[13.007 0.079]

    4x 73 0.175[2.874 0.007]

    2x 146 0.35[5.7480.014]

    THREAD : M12x1.75-6H THDDEPTH: 25 [0.984] MIN.4x

    P301 301

    mm

    [in]

  • 7/28/2019 115-130_11063346

    27/40

    2711063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Dimensions

    Auxiliary Mounting Pads

    (continued)

    C Caution

    Standard pad cover is installed only to retain coupling during shipping. Do not operatepump without an auxiliary pump or running cover installed.

    Specications

    Option Spline

    Torque rating1

    maximum torque

    Nm [lbfin]

    H6 14 teeth, 12/24 pitch 816 [7220]1) For denitions of maximum torque values, refer to:

    Basic Inormation Manual 11062168, section Shat Torque Ratings and Spline Lubrication. T000 154E

    Option H6, ISO 3019-1, fange 127-4 (SAE C, 14 teeth)

    P003 390E

    181.0 0.35

    [7.126 0.014]

    15.0 0.25

    [0.591 0.010]

    333.23 2.0

    [13.119 0.079]

    317.73 2.0

    [12.509 0.079]

    2x 90.5 0.175

    [3.563 0.007]

    134.0

    6

    +0.

    13

    0

    [5.2

    78

    +0.

    05

    0

    ]

    127.0

    5

    +0.0

    76

    0

    [5.0

    02

    +0.0

    03

    0

    ]

    23.3 + 1.0 0

    [0.917 + 0.039 0

    ]

    1.956

    [0.077]4x 114.5 0.35

    [4.508 0.014]

    8x 57.25 0.175

    [2.254 0.007]

    Mounting flange surface

    Flange 127 - 4 per ISO 3019-1to be paint free

    Spline data

    Number of teeth : 14Pitch fraction : 12/24Pressure angle : 30Pitch- : 29.633 [1.167]

    Typ of fit : Fillet root sideper : Ansi B92.1-1996 class 6

    R 0.8 max.[0.031]

    O-ring seal required

    ref 120.32 [4.737] I.D.x 2.62 [0.103] cross section

    Thread : M12x1.75-6H THD

    Depth : 25.0 [0.984] min.4x

    Thread : M16x2.0-6H THD

    Depth : 28.5 [1.122] min.2x

    mm

    [in]

  • 7/28/2019 115-130_11063346

    28/40

    28 11063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Auxiliary Mounting Pads

    (continued)

    C Caution

    Standard pad cover is installed only to retain coupling during shipping. Do not operatepump without an auxiliary pump or running cover installed.

    Specications

    Option Spline

    Torque rating1

    maximum torque

    Nm [lbfin]

    H4 13 teeth, 8/16 pitch 2206 [19 500]1) For denitions of maximum torque values, refer to:

    Basic Inormation Manual 11062168, section Shat Torque Ratings and Spline Lubrication. T000 203E

    Option H4, ISO 3019-1, fange 152-4 (SAE D, 13 teeth)

    P003 391E

    4x 161.6 0.35

    [6.362 0.014]

    14.0 0.25[0.551 0.010]

    338.107 2.0

    [13.311 0.079]

    316.915 2.0

    [12.477 0.079]8x 80.8 0.175

    [3.181 0.007]

    159.0

    +0.1

    3

    0

    [6.2

    60

    +0.0

    5

    0

    ]

    152.4

    5

    +0.0

    7

    6

    0

    [6.0

    02

    +0.0

    0

    3

    0

    ]

    27.48 + 1.0 0

    [1.082 + 0.039 0

    ]

    2.5[0.098]

    O-ring seal required

    ref 150.0 [5.906] I.D.x 3.0 [0.118] cross section

    Spline data

    Number of teeth : 13Pitch fraction : 16/32Pressure angle : 30Pitch- : 41.275 [1.625]

    Typ of fit : Fillet root sideper : Ansi B92.1-1996 class 6

    Thread : M20x2.5-6H THD

    Depth : 30.0 [1.181] min.4x

    Mounting flange surface

    Flange 152 - 4 per ISO 3019-1to be paint free

    mm

    [in]

    Dimensions

  • 7/28/2019 115-130_11063346

    29/40

    2911063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Charge Pump Charge pump sizing/selection

    In most applications a general guideline is that the charge pump displacement should

    be at least 10 % of the total displacement of all components in the system. Unusualapplication conditions may require a more detailed review of charge ow requirements.Please refer to BLN-9885, Selection of Drive line Components, for a detailed procedure.

    System features and conditions which may invalidate the 10 % guideline include (but arenot limited to): Continuous operation at low input speeds (< 1500 min-1 (rpm)) High shock loading and/or long loop lines High ushing ow requirements Multiple Low Speed High Torque motors High input shaft speeds

    Contact your Sauer-Danfoss representative for application assistance if your applicationincludes any of these conditions.

    Charge pump fow and power curves

    Charge pressure: 20 bar [290 psi]Viscosity and temperature: 11 mm2/s [63 SUS] 80 C [180 F]

    Charge pump fow Charge pump power requirements

    P003 335E

    0 500 15001000 2000

    Speed min-1(rpm)

    30002500 3500

    10027

    24

    21

    18

    15

    12

    9

    6

    3

    1

    90

    80

    70

    60

    50

    40

    30

    20

    10

    0

    l/min

    USgal/min

    34

    cm3 [

    2.07

    in3/r

    ev]

    26

    cm

    3 [1.59

    in3/r

    ev]

    P003 337E

    14.0

    10

    9

    8

    7

    6

    5

    4

    3

    2

    1

    0

    13.0

    12.0

    11.0

    10.0

    9.0

    8.0

    7.0

    6.0

    5.0

    4.0

    3.0

    2.0

    1.0

    HP

    Kw

    34cm

    3 [2.07

    in3/r

    ev]

    26cm

    3 [1.59in

    3/rev]

    0 500 15001000 2000

    Speed min-1(rpm)

    30002500 3500

    Charge Pump

  • 7/28/2019 115-130_11063346

    30/40

    30 11063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Installation Drawings

    Please contact Sauer-Danoss or specifc installation drawings

    Port description

    Charge inlet port S

    Port ISO 11926-1 1 5/8-1269.0 max clearance dia for fitting

    Case drain port L4

    Port ISO 11926-1 1 5/16-1263.0 max clearance dia for fitting

    Case pressure port

    Port ISO 11926-1 1 1/16-1241.0 max clearance dia for fitting

    Servo gage port M4

    Port ISO 11926-1 7/16-2024.5 max clearance dia for fitting

    System port B

    31.5 450 barSplit flange bossper ISO 6162M12 x 1.7520 min.full thread depth

    System port A

    31.5 450 barSplit flange bossper ISO 6162M12 x 1.7520 min.full thread depth

    Connector :

    Deutsch DT04-2Pto be paint free

    System A gage port MA

    Port ISO 11926-1 9/16-1828.0 max clearance dia for fitting

    P003 392E

    Port description

    Port Description Sizes

    A System port A 31.5

    B System port B 31.5

    E Charge fltration port, rom flter 1 1/16 -12

    F Charge fltration port, to flter 1 1/16 -12

    L2 Case drain port 1 5/16 -12

    L4 Case drain port 1 5/16 -12

    MA System A gage port 9/16 -18

    MB System B gage port 9/16 -18

    M3 Charge gage port, ater fltering 9/16 -18

    M4 Servo gage port 7/16 -20

    M5 Servo gage port 7/16 -20

    M14 Case gage port 7/16 -20

    S Charge inlet port 1 5/8 -12

    T301 028E

  • 7/28/2019 115-130_11063346

    31/40

    3111063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Installation Drawings

    Please contact Sauer-Danoss or specifc installation drawings

    Port description

    (continued)

    Charge pressure port

    Port ISO 11926-1 5/16-24

    Case pressure port

    Port ISO 11926-1 1 1/16-1241.0 max clearance dia for fitting

    Charge gage port M3Port ISO 11926-1 9/16-1828.0 max clearance dia for fittingafter filtering

    Servo gage port M5

    Port ISO 11926-1 7/16-2024.5 max clearance dia for fitting

    Charge pressure port

    Port ISO 11926-1 5/16-24

    Case drain port L2

    Port ISO 11926-1 1 5/16-1263.0 max clearance dia for fitting

    Connector :

    Deutsch DT04-2Pto be paint free

    System B gage port MB

    Port ISO 11926-1 9/16-1828.0 max clearance dia for fitting

    P003 393E

    Case gage port M14

    Port ISO 11926-1 7/16-2021.0 max clearance dia for fitting(EDC, FNR, NFPE)

    OptionalCharge filtration port F

    Port ISO 11926-1 1 1/16-12to filter42 max clearance dia for fitting

    OptionalCharge filtration port E

    Port ISO 11926-1 1 1/16-12from filter42 max clearance dia for fitting

  • 7/28/2019 115-130_11063346

    32/40

    32 11063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Installation Drawings

    Please contact Sauer-Danoss or specifc installation drawings

    Dimensions

    Charge inlet port S

    Port ISO 11926-1 1 5/8-1269.0 max. clearance dia for fitting

    Case drain port L4

    Port ISO 11926-1 1 5/16-1263.0 max. clearance dia for fitting

    Case pressure port

    Port ISO 11926-1 1 1/16-1241.0 max. clearance dia for fitting

    Servo gage port M4

    Port ISO 11926-1 7/16-2024.5 max. clearance dia for fitting

    System port B

    31.5 450 barSplit flange bossper ISO 6162M12 x 1.7520 min.full thread depth

    System port A

    31.5 450 barSplit flange bossper ISO 6162M12 x 1.7520 min.full thread depth

    Connector :Deutsch DT04-2Pto be paint free

    12.45 0.25[0.49 0.01]

    46.4 1.0[1.827 0.039]

    141.5 1.0[5.571 0.039]

    167.4 1.0[6.591 0.039]

    67.0 1.0

    [2.638 0.039]

    162.4 1.0[6.394 0.039]

    77.2

    1.0

    [3.0

    39

    0.0

    39]

    178.4

    1.0

    [7.0

    24

    0.0

    39]

    151.5

    1.0

    [5.9

    65

    0.0

    39]

    132.0

    1.0

    [5.1

    97

    0.0

    39]

    4x 66.6 0.25[2.622 0.010]

    4x31.8

    0.2

    5

    [1.2

    52

    0.0

    10]

    8x 33.3 0.25

    [1.311 0.010]8x1

    5.9

    0.2

    5

    [0.6

    26

    0.0

    10]

    8.05 0.8[0.317 0.031]

    17.9 0.2[0.705 0.008]

    65.0 0.2[2.559 0.008]

    110.9 0.2[4.366 0.008]

    106.5 0.2[4.193 0.008]

    316.846 2.0[12.474 0.079]

    R 0.8 max.[0.031]

    1.5 0.5 x 455[0.059 0.028 x 45]

    152.4

    +0

    0.0

    5

    [6.0

    +0

    0.0

    02

    ]

    80.0

    +0.1

    0.2

    [3.1

    5

    +0.0

    04

    0.0

    08

    ]

    80.0

    +0.1

    0.2

    [3.1

    5

    +0.0

    04

    0.0

    08

    ]

    239.415 + 0.6 0.5

    [9.426 + 0.024

    0.02

    ]

    Shaft LCShaft LCShaft LC

    P003 394E

    Mounting flange surface

    Flange 152 - 4 per ISO 3019-1to be paint free

    BB2x DDCC

    Z

    D

    D

    B

    B

    C

    C

    mm

    [in]

  • 7/28/2019 115-130_11063346

    33/40

    3311063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Installation Drawings

    Please contact Sauer-Danoss or specifc installation drawings

    Dimensions

    (continued)

    8.0

    1.0

    [0.3

    15

    0.0

    39]

    Charge gage port M3

    Port ISO 11926-1 9/16-1828.0 max. clearance dia for fittingafter filtering

    Servo gage port M5

    Port ISO 11926-1 7/16-2024.5 max. clearance dia for fitting

    167.4 1.0[6.591 0.039]

    141.5 1.0[5.571 0.039]

    162.4 1.0[6.394 0.039]

    158.4[6.24]

    254.415 1.0[10.016 0.039]

    254.415 1.0[10.016 0.039]

    257.115 1.0[10.123 0.039]

    46.4 1.0[1.827 0.039]

    132.0

    1.0

    [5.1

    97

    0.0

    39]

    24.5

    [0.9

    7]

    149.98 1.0

    [5.905 0.039]

    1.0

    [0.04]

    121.89 2.0

    [4.799 0.079]

    204.2

    6

    1.0

    [8.0

    420.0

    39]

    110.01.0

    [4.3

    310.0

    39]

    151.51.0

    [5.9

    650.0

    39]

    178.2

    61.0

    [7.0

    180.0

    39]

    209.0max.

    [8.2

    28]

    128.42.0

    [5.0

    550.0

    79]

    64.21.0

    [2.5

    280.0

    39]

    91.01.0

    [3.5

    830.0

    39]

    69.01.0

    [2.7

    170.0

    39]

    113.61.0

    [4.4

    720.0

    39]

    113.31.0

    [4.4

    610.0

    39]

    106.5 0.2[4.193 0.008]

    Case pressure port

    Port ISO 11926-1 1 1/16-1241.0 max. clearance dia for fitting

    Connector :

    Deutsch DT04-2Pto be paint free

    Charge pressure port

    Port ISO 11926-1 5/16-24

    Approximate center

    of gravity

    Approximate centerof gravity

    Case drain port L2

    Port ISO 11926-1 1 5/16-1263.0 max. clearance dia for fitting

    Charge pressure port

    Port ISO 11926-1 5/16-24

    Charge filtration port F

    Port ISO 11926-1 1 1/16-1242.0 max. clearance dia for fitting

    to filterCharge filtration port E

    Port ISO 11926-1 1 1/16-1242.0 max. clearance dia for fittingfrom filter

    Case gage port M14

    Port ISO 11926-1 7/16-2021.0 max. clearance dia for fitting

    System B gage port MB

    Port ISO 11926-1 9/16-1828.0 max. clearance dia for fitting

    11

    Chargefiltrationport EPortISO11926-1 11/16-1242.0max.clearancediaforfitting

    fromfilter

    Chargefiltrationport FPortISO11926-1 11/16-1242.0max.clearancediaforfitting

    tofilter

    11

    P003 395EShaft LC Shaft LC

    Shaft LC

    W

    Y

    X

    ViewY

    ViewZ

    E-E F-F G-G

    F F

    EE

    G

    G

    mm

    [in]

  • 7/28/2019 115-130_11063346

    34/40

    34 11063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Installation Drawings

    Please contact Sauer-Danoss or specifc installation drawings

    Dimensions

    (continued)

    (4x)20.6 + 0.25 0.13

    [0.811 + 0.01

    0.005

    ](4x) 80.8 0.25[3.18 0.01]

    CCWRotation

    CWRotation

    239.415 1.0[9.426 0.039]

    87.5

    1.0

    [3.4

    45

    0.0

    3

    9]

    (4x)80.8

    0.2

    5

    [3.1

    8

    0.0

    1]

    (4x)40.0 0.25

    [1.575 0.01]other side screw head space

    P003 396ESystem A gage port MA

    Port ISO 11926-1 9/16-1828.0 max. clearance dia for fitting

    ViewW

    ViewX

    mm

    [in]

  • 7/28/2019 115-130_11063346

    35/40

    3511063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Installation Drawings

    Please contact Sauer-Danoss or specifc installation drawings

    Controls

    Electric Displacement Control (EDC),optionA2 (12 V)/A3 (24 V)

    Electric Displacement Control (EDC), with manual override,

    optionA4 (12 V)/A5 (24 V)

    Dimensions

    (continued)

    P003 397E

    Shaft LC

    Mounting flange

    Shaft LC

    Connector :Deutsch DT04-2Pto be paint free

    Connector :Deutsch DT04-2Pto be paint free

    204.32.0

    [8.0

    420.0

    79]

    128.42.0

    [5.0

    550.0

    79]

    64.2

    1.0

    [2.5

    28

    0.0

    39]

    2x178.31.0

    [7.0

    180.0

    39]

    2x 141.5 1.0[5.571 0.039]

    79.4 1.0[3.13 0.039]

    Case gage port M14

    Port ISO 11926-1 7/16-2021 max clearance dia for fitting

    209.0max

    [8.2

    28]

    P003 398E

    Shaft LC

    Mounting flange

    Shaft LC

    Connector :Deutsch DT04-2Pto be paint free2

    04.32.0

    [8.0

    420.0

    79]

    128.42.0

    [5.0

    550.0

    79]

    6

    4.21.0

    [2.5

    280.0

    39]

    Case gage port M14

    Port ISO 11926-1 7/16-2021 max clearance dia for fitting

    2x178.31.0

    [7.0

    180.0

    39]

    2x 141.5 1.0[5.571 0.039]

    209.0max

    [8.2

    28]

    79.4 1.0[3.13 0.039]

    Connector :Deutsch DT04-2Pto be paint free

    mm

    [in]

  • 7/28/2019 115-130_11063346

    36/40

    36 11063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Installation Drawings

    Please contact Sauer-Danoss or specifc installation drawings

    Controls

    Forward-Neutral-Reverse (FNR) with manual override,optionA9(12 V)/B1 (24 V)

    Non Feedback Proportional Electric control (NFPE), with manual override,

    optionA8 (12 V)/B8 (24 V)

    Dimensions

    (continued)

    P003 399E

    Shaft LC

    Mounting flange

    Shaft LC

    Connector :

    Deutsch DT04-2Pto be paint free2

    04.62.0

    [8.0

    540.0

    79]

    128.42.0

    [5.0

    550.0

    79]

    64.21.0

    [2.5

    280.0

    39]

    Case gage port M14

    Port ISO 11926-1 7/16-2021 max clearance dia for fitting

    2x178.31.0

    [7.0

    180.0

    39]

    2x 141.5 1.0[5.571 0.039]

    209.0max

    [8.2

    28]

    79.4 1.0[3.13 0.039]

    Connector :Deutsch DT04-2Pto be paint free

    P003 400E

    Shaft LC

    Mounting flange

    Shaft LC

    Connector :

    Deutsch DT04-2Pto be paint free2

    04.32.0

    [8.0

    420.0

    79]

    128.42.0

    [5.0

    550.0

    79]

    64.2

    1.0

    [2.5

    28

    0.0

    39]

    2x178.31.0

    [7.0

    180.0

    39]

    2x 141.5 1.0[5.571 0.039]

    209.0max

    [8.2

    28]

    79.4 1.0[3.13 0.039]

    Case gage port M14

    Port ISO 11926-1 7/16-2021 max clearance dia for fitting

    Connector :Deutsch DT04-2Pto be paint free

    mm

    [in]

  • 7/28/2019 115-130_11063346

    37/40

    3711063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Installation Drawings

    Please contact Sauer-Danoss or specifc installation drawings

    Displacement limiters

    Displacement limiters,optionB andD

    Dimensions

    (continued)

    P003 401E

    167.0 2.0

    [6.575 0.079]

    140.86 1.0

    [5.546 0.039]

    103.3

    1.0

    [4.0

    67

    0.0

    39]

    167.0 2.0

    [6.575 0.079]

    Wrench size 6

    (internal hex)

    Wrench size 22

    (external hex)

    mm

    [in]

  • 7/28/2019 115-130_11063346

    38/40

    38 11063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Installation Drawings

    Please contact Sauer-Danoss or specifc installation drawings

    Dimensions

    (continued)

    Filtration

    Suction ltration,option L

    239.4

    1.0

    [9.4

    26

    0.0

    39]

    System port B

    31.5 450 barSplit flange bossper ISO 6162M12 x 1.7520 min.

    full thread depth

    System port A

    31.5 450 barSplit flange bossper ISO 6162M12 x 1.75

    20 min.full thread depth

    Charge inlet port S

    Port ISO 11926-1 1 5/8-1269 max. clearance dia for fitting

    System B gage port MB

    Port ISO 11926-1 9/16 -1828 max. Clearance Dia for Fitting

    Charge pressure port

    Port ISO 11926-1 5/16 -24

    P003 403E

    mm

    [in]

  • 7/28/2019 115-130_11063346

    39/40

    3911063346 Rev BE Mar 2011

    H1 Axial Piston Pump, Size 115/130, Single

    Technical Inormation

    Installation Drawings

    Please contact Sauer-Danoss or specifc installation drawings

    Dimensions

    (continued)

    Filtration

    Integral ull fow charge pressure ltration with lter bypass sensor,optionM

    Charge gage port M6

    Port ISO 11926-1 9/16-18before filter

    77.749 1.0[3.061 0.039]

    41.619 1.0[1.639 0.039]

    306.916 1.0[12.083 0.039]

    298.1 1.0[11.739 0.039]

    15.9 1.0[0.627 0.039]

    201.2

    65

    1.0

    [7.9

    24

    0.0

    39]

    223.7

    2.0

    [8.8

    05

    0.0

    79]

    138.3

    2.0

    [5.4

    44

    0.0

    79]

    175.2

    65

    1.0

    [6.9

    00

    0.0

    39]

    Connector :

    Deutsch DTM04-2Pto be paint free

    P003 404E

    mm

    [in]

  • 7/28/2019 115-130_11063346

    40/40

    Local address:

    Sauer-Danfoss GmbH & Co. OHG

    Postfach 2460, D-24531 Neumnster

    Krokamp 35, D-24539 Neumnster, Germany

    Phone: +49 4321 871 0

    Sauer-Danfoss ApS

    DK-6430 Nordborg, Denmark

    Phone: +45 7488 4444

    Fax: +45 7488 4400

    Sauer-Danfoss is a global manufacturer and supplier of high-

    quality hydraulic and electronic components. We specialize in

    providing state-of-the-art technology and solutions that excel inthe harsh operating conditions of the mobile o-highway market.

    Building on our extensive applications expertise, we work closely

    with our customers to ensure exceptional performance for a broad

    range of o-highway vehicles.

    We help OEMs around the world speed up system development,

    reduce costs and bring vehicles to market faster.

    Sauer-Danfoss Your Strongest Partner in Mobile Hydraulics.

    Go to www.sauer-danfoss.com for further product information.

    Wherever o-highway vehicles are at work, so is Sauer-Danfoss.

    We oer expert worldwide support for our customers, ensuring

    the best possible solutions for outstanding performance. And with

    an extensive network of Global Service Partners, we also provide

    comprehensive global service for all of our components.

    Please contact the Sauer-Danfoss representative nearest you.

    Products we oer:

    Bent Axis Motors

    Closed Circuit Axial Piston Pumps

    and Motors

    Displays

    Electrohydraulic Power Steering

    Electrohydraulics

    Hydraulic Power Steering

    Integrated Systems

    Joysticks and Control Handles

    Microcontrollers and Software

    Open Circuit Axial Piston Pumps

    Orbital Motors

    PLUS+1 GUIDE

    Proportional Valves

    Sensors

    Steering

    Transit Mixer Drives

    Members of the Sauer-Danfoss Group:

    Comatrol

    www.comatrol.com

    Schwarzmller-Inverter

    www.schwarzmueller-inverter.com

    Turolla

    www.turollaocg.com

    Hydro-Gear

    www.hydro-gear.com

    Sauer-Danfoss (US) Company

    2800 East 13th Street

    Ames, IA 50010, USA

    Phone: +1 515 239 6000

    Fax: +1 515 239 6618

    Sauer-Danfoss-Daikin LTD.

    Shin-Osaka TERASAKI 3rd Bldg. 6F

    1-5-28 Nishimiyahara, Yodogawa-ku

    Osaka 532-0004 Japan