flat top block presentation 18.05.13
Post on 12-Nov-2014
391 Views
Preview:
DESCRIPTION
TRANSCRIPT
SUSTAINABILITY PRESENTATION
DESIGN OVERVIEW
• Maximise Site• Existing balconies and access decks• New access deck and balcony structure • Retain as much of the fabric as possible • Use sustainable materials
SITE
• Maximise site• Sedum roof• Planting• Bike store• Solar Panels
CARBON EMISSIONS & ENERGY USE
EXISTING BER PROPOSED BER
A2
E1
SUSTAINABLE COMMUNITY
• Community Space• Enclosed site• Communal garden • Play ground• Apartment mix
HEALTH & WELLBEING
• Tenants retain location • Apartment size increased• Balcony size increased• Part M compliance• Communal gardens/
playground • Fuel poverty • VOC• Daylighting • Minimise LTB, Eliminate
mould
MATERIALS
Cavity: Loose Wood Fibre Insulation
EWI: NBT Diffutherm Wood Fibre Boards
Render: Baumic Breathable Lime Render
Inverted Roof: Kingspan Stryozone InsulationGround Slab: Kingspan Therma Insulation
U VALUES
LINEAR THERMAL BRIDGELocation of Junction Reference
L2D l x U Wall/ Floor 1 l x U Wall/ Floor 2 Ψ Note
U factor l m L2D U l l x U U l l x U L2D- (l1 x U1+ l1 x U1)
Ground Floor/ External Wall 1 0.1099 5 0.5495 0.1314 1 0.1314 0.0956 4 0.3824 0.0357
External Wall/ GF Ceiling &FF Floor 2 0.0783 4 0.3132 0.1314 1 0.1314 0.1314 1 0.1314 0.0252divided by 2
Timber Prefab Panel Party Wall/ External Wall 3 0.0768 4 0.3072 0.1314 1 0.1314 0.1314 1 0.1314 0.0222divided by 2
Timber Prefab Panel Lintels 4 0.114 1.176 0.134064 0.1314 1 0.1314 0 0.0027
Timber Prefab Panel Sill 5 0.1145 1.206 0.138087 0.1314 1 0.1314 0.0067
Timber Prefab Panel Jamb 6 0.114 1.176 0.134064 0.1314 1 0.1314 0.0027
Ground Threshold 7 0.1251 4.261 0.533051 0 0.0956 4 0.3824 0.1507
Timber Prefab Panel Gable Corner 8 0.1282 3.285 0.421137 0.0967 2.265 0.219026 0.1314 1 0.1314 0.0707
Existing Gable Wall/ Ground 9 0.1415 6.284 0.889186 0.0967 2.265 0.219026 0.0956 4 0.3824 0.2878
Ground Gable Ceiling 10 0.0709 6.6 0.46794 0.0967 2.265 0.219026 0.0967 2.265 0.219026 0.0149divided by 2
First Floor Ceiling 11 0.0719 5.619 0.404006 0.1314 1 0.1314 0.0991 2.235 0.221489 0.0256divided by 2
Existing Cavity Wall/ Party Wall 12 0.0751 6.445 0.48402 0.0991 2.235 0.221489 0.0991 2.235 0.221489 0.0205divided by 2
Existing Cavity Wall Lintels 13 0.089 2.616 0.232824 0.0991 2.235 0.221489 0.0113
Existing Cavity Wall Jambs 14 0.089 2.616 0.232824 0.0991 2.235 0.221489 0.0113
Existing Cavity Wall Sill 15 0.0862 2.659 0.229206 0.0991 2.235 0.221489 0.0077
Balcony Door/ Slab 16 0.0246 2.497 0.061426 0.0307divided by 2
CONDENSATION RISK
TSI Te TI fRsi
19.5 0 20 0.9819.8 0 20 0.9919.8 0 20 0.9919.7 0 20 0.9919.8 0 20 0.9919.7 0 20 0.9918.1 0 20 0.9119.5 0 20 0.9818.2 0 20 0.9119.8 0 20 0.9919.8 0 20 0.9919.8 0 20 0.9919.7 0 20 0.9919.7 0 20 0.9919.8 0 20 0.9919.8 0 20 0.99
TEMPERATURE FACTOR
FRsi= (Tsi-Te)/(Ti-Te)=(or greater than FCRsi)0.75
Ground Floor/ External Wall
External Wall/ GF Ceiling &FF Floor
Timber Prefab Panel Party Wall/ External Wall
Timber Prefab Panel Lintels
Timber Prefab Panel Sill
Timber Prefab Panel Jamb
Ground Threshold
Timber Prefab Panel Gable Corner
Existing Gable Wall/ Ground
Ground Gable Ceiling
First Floor Ceiling
Existing Cavity Wall/ Party Wall
Existing Cavity Wall Lintels
Existing Cavity Wall Jambs
Existing Cavity Wall Sill
Balcony Door/ Slab
LTB LOCATION
EXISTING BUILDING EMBODIED CARBON
SYSTEMS
BREEAM
FLAT TOP BLOCK
top related