Page 1: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Circular Dichroism

Page 2: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Circular Dichroism?

원편광 이색성 CD spectroscopy measures differences in the

absorption of left-handed polarized light versus right-handed polarized light which arise due to structural asymmetry

분광학 (Spectroscopy) 물질과 전자기파 ( 빛 ) 의 상호작용을 연구 ,

물질에서 방출되거나 물질에 흡수되는 스펙트럼을 분석하여 물질을 분석

Page 3: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Circular Dichroism?

단백질 거울상 (chiral) 이상질체인 D form과 L form 으로 구성 D/ L form 이 동일한 양으로 구성된

화합물을 Racemic mixture 편광된 빛이 asymmetric medium 을

통과하면 optical rotation 과 polarization loss 일어남 Ellipticity(loss) 를 측정하여 ellipticity

크기와 경향을 diagram 으로 나타낸 것이 Circular Dichroism

Page 4: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Light

As an electromagnetic wave Electrical component Magnetic component

Direction Two component 는 서로 수직 빛의 진행방향에도 서로 수직

Page 5: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Polarization( 편광 )

진행방향에 대해 수직으로 진동= 횡파의 특성

횡파의 경우 , 진동방향이 파동의 진행방향의 수직인 평면상에 놓여있게 되어 벡터의 성격을 갖게됨

편광 = 파동의 진동이 그 평면상의 특정 방향으로 놓이게 되는 것

편광방향 = 진동방향 ( 물질에 더 큰 영향을 주는 전기장의 진동방향 )

Page 6: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Polarization( 편광 )

빛은 짧은 길이의 무수히 많은 파동줄기(wave train) 가 모여서 형성된 것이므로 하나하나의 편광상태가 어떻게 집합되어 있는가를 고려해야 하므로 통계적인 처리가 필요

빛은 물질과 반응하여 편광상태가 바뀔 수 있음

Page 7: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Polarization( 편광 )

선형편광 = 편광방향이 바뀌지 않음 전기장이 x 방향으로 진동하는 경우를 x

선형편광 , y 방향 진동의 경우 y 선형편광

x, y 선형편광을 적절히 조합하면 임의의 방향의 선형편광이나 , 원형편광도 만들어 낼 수 있다 .

Page 8: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Polarization( 편광 )

전기장의 방향은 나선 형태로 계속 변함 z 축 상의 한 점에 정지 한 채로 보면

다가오는 빛의 전기장은 점차 반 시계방향으로 회전을 하게 되는 것을 알 수 있다 ( 좌향 - 원형편광 )

Page 9: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Polarization

Page 10: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Dichroism

The difference between the absorption of left and right handed circularly-polarized light is measured as a function of wavelength

Page 11: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Principle of CD

Chiral molecules 은 좌원편광 , 우원편광 된 빛을 다르게 흡수 -> CD spectrum

Chiral molecules 은 optical active Optical activity = 편광 된 빛이 물질을

통과할 때 편광 면을 회전시키는 성질

Page 12: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

(a) Linear polarized light can be viewed as a superposition of opposite circular polarized light of equal amplitude and phase

(b) Different absorption of the left- and right hand polarized component leads to ellipticity (CD) and optical rotation (OR)

(a)

(b)

Page 13: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

is therefore the angle between the initial plane of polarization and the major axis of the ellipse of the resultant transmitted light

A quantity is defined such thattan is the ratio of the major and minor axis of the ellipse of the transmitted light

’ approximates the ellipticity When expressed in degrees, ’ can be converted to a

specific ellipticity [] or a molar ellipticity [] CD is usually plotted as []

θ100.3032εε

10θ y ellipticitmolar

dc' y ellipticit specific

3rl

2

M

Page 14: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

스펙트럼

자외선 가시광선에 의해 분자나 원자가 에너지를 흡수하여 전이를 일으켜 발생

흡수된 빛의 파장은 낮은 에너지준위의 전자를 높은 에너지 준위로 이동시킬 수 있는 에너지가 있음

Page 15: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

전자전이 결합분자 궤도 함수 (bonding moleculer

orbital): , ( 에너지 준위가 낮음 )

반 결합 분자궤도 함수 (antibonding moleculer orbital): *, * ( 에너지 준위가 높음 )

비결합 전자 (nonbonding electron): n 전자 ( 유기 화합물 중 O, N, S 및 할로겐 원자 )

전자의 전이는 전자가 결합성 궤도 함수(bonding orbital) 에서 반결합성 궤도 함수(anti-bonding orbital) 로 옮아가는 것을 의미함

Page 16: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Application

Near UV CD (250 - 350 nm) Near-UV CD spectroscopy is dominated by

Phe, Tyr, Trp and disulfides When an aromatic residue is held rigidly in

space, its environment is asymmetric, and it will exhibit CD

Page 17: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Application

Far UV CD (180 - 250 nm) The amide group is the most abundant

CD chromophore in proteins In secondary structure conformations,

the backbone and the amide bond chromophores are arranged in regular, organized, asymmetric patterns

Page 18: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Application

n -> π* centered around 220 nm n -> π* involves non-bonding

electrons of O of the carbonyl π -> π* centered around 190 nm π -> π* involves the π-electrons of

the carbonyl The intensity and energy of these

transitions depends on φ and ψ (i.e., secondary structure)

Page 19: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Application Far UV-CD of random coil:

positive at 212 nm (π->π*) negative at 195 nm (n->π*)

Far UV-CD of β-sheet: negative at 218 nm (π->π*) positive at 196 nm (n->π*)

Far UV-CD of α-helix: Exciton coupling of the π->π* transitions leads to

positive (π->π*)(perpendicular) at 192 nm and negative (π->π*)(parallel) at 209 nm

negative at 222 nm is red shifted (n->π*)

Page 20: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Application

Determination of secondary structure of proteins that cannot be crystallized

Investigation of the effect of e.g. drug binding on protein secondary structure

Studies of the effects of environment on protein structure

Study of ligand-induced conformational changes

Page 21: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Application

광우병 진단 정상적인 cellular prion protein 의 경우 ,

단백질의 2 차 구조가 대부분 alpha-helix로 이루어져 있다 .

반면 , 광우병에 걸린 scrapie prion protein은 beta structure 가 대부분의 2 차 구조 구성 성분으로 변하게 된다 .

Alpha helical structure 에서 beta-structure 로의 변화를 CD 를 통해 확인할 수 있고 , 광우병의 발병유무를 측정가능하다 .

Page 22: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Sample Preparation

Additives, buffers and stabilizing compounds: Any compound which absorbs in the region of interest (250 - 190 nm) should be avoided.

A buffer or detergent or other chemical should not be used unless it can be shown that the compound in question will not mask the protein signal.

Page 23: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Sample Preparation

Protein solution: From the above follows that the protein solution should contain only those chemicals necessary to maintain protein stability, and at the lowest concentrations possible. Avoid any chemical that is unnecessary for protein stability/solubility. The protein itself should be as pure as possible, any additional protein or peptide will contribute to the CD signal.

Page 24: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Sample Preparation

Contaminants: Unfolded protein, peptides, particulate matter (scattering particles), anything that adds significant noise (or artifical signal contributions) to the CD spectrum must be avoided. Filtering of the solutions (0.02 um syringe filters) may improve signal to noise ratio.

Data collection: Initial experiments are useful to establish the best conditions for the "real" experiment. Cells of 0.5 mm path length offer a good starting point.

Page 25: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Sample Preparation

Nitrogen purging: the function of purging the CD instrument with nitrogen is to remove oxygen from the lamp housing, monochromater, and the sample chamber. The reason for removing oxygen is that oxygen absorbs deep UV light, thus reducing the light available for the measurement.

Page 26: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Sample Preparation

Typical Initial Concentrations: Protein Concentration: 0.5 mg/ml Cell Path Length: 0.5 mm Stabilizers (Metal ions, etc.): minimum Buffer Concentration : 5 mM or as low as

possible while maintaining protein stability

Need very little sample: 0.1mg

Page 27: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Advantage

Simple and guick experiment No extensive preparation Measurements on solution phase Relatively low concentrations/amounts of

sample Microsecond time resolution Any size of macromolecule

Page 28: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Disadvantage

Difficult to quantitate similarity or differences

Certain buffer components absorb strongly in Far-UV & can cause interference

Page 29: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Conclusion

편광된 빛이 asymmetric medium 을 통과하면 optical rotation 과 polarization loss 일어남 Ellipticity(loss) 를 측정하여 ellipticity

크기와 경향을 diagram 으로 나타낸 것이 Circular Dichroism

Near UV CD (250 - 350 nm) Near-UV CD spectroscopy is dominated by

Phe, Tyr, Trp and disulfides

Page 30: Circular Dichroism. Circular Dichroism?  원편광 이색성  CD spectroscopy measures differences in the absorption of left-handed polarized light versus right-handed

Conclusion

Far UV CD (180 - 250 nm) In secondary structure conformations,

the backbone and the amide bond chromophores are arranged in regular, organized, asymmetric patterns

Random coil, β-sheet, α-helix