491 ANH VIEÄT ÑOÁI CHIEÁU ° ACB - air circuit breakers maùy caét khoâng khí ° ACR - automatic circuit recloser maùy caét töï ñoùng laïi ° ACE - area control error ° ADC - analog digital converter boä bieán ñoåi töông töï - soá ° AFC - automatic frequency control ñieàu khieån taàn soá töï ñoäng ° ALU - arithmatic and logic unit ° AGC - automatic generation control ° AMR - automated meter reading ñieàu khieån phaân phoái coâng suaát töï ñoäng ñoïc ñieän keá töï ñoäng ° ATS - automatic transfer switch thieát bò chuyeån nguoàn töï ñoäng ° ARS - autoreclosing schemes sô ñoà töï ñoùng laïi töï ñoäng ° AVR - automatic voltage regulator boä ñieàu chænh ñieän aùp töï ñoäng ° admittance relays rôle toång daãn ° amplidyne khueách ñaïi quay ° anti-pumping divice ° APGS - automatic protection group selection boä phaän choáng ñoùng laäp ñi laäp laïi cuûa ACR löïa choïn nhoùm baûo veä ° apparent impedance ° AR - auto restoration toång trôû bieåu kieán ño ñöôïc bôûi rôle, toång trôû nhìn thaáy bôûi rôle töï ñoäng taùi laäp löôùi ñieän ° back-up protection baûo veä döï tröõ (BVDT) ° balance point-reach, setting-tripping threshold ngöôõng taùc ñoäng ° block khoaù, caám ° biased differential relays rôle so leäch coù haõm ° bushing current transformer BI söù ° brushless exitation system heä thoáng kích thích khoâng choåi than ° by pass ° communication media noái taét moâi tröôøng truyeàn tin ° comparator ° CPS - communication port switch boä so saùnh khoùa lieân keát truyeàn tin ° CB-circuit breakers ° cold load pickup maùy caét (MC) doøng töï khôûi ñoäng ° current transformers ° communication processor maùy bieán doøng ñieän (BI) boä xöû lyù truyeàn tin ° DAS-data acquisition systems ° CAPM - control and protection module heä thoáng thu thaäp döõ lieäu khoái baûo veä vaø ñieàu khieån ° D-C components ° DAS - distribution automation system thaønh phaàn 1 chieàu, khoâng chu kì heä thoáng töï ñoäng phaân phoái ° Damping Winding cuoän caûn ° Dead line ° DFR - digital fault recorder ñöôøng daây chöa mang ñieän boä ghi söï coá ° definite time current caracteristic ñaëc tính doøng ñieän-thôøi gian ñoäc laäp

Upload: tran-van-hieu

Post on 18-Jul-2016

6 views

Category:

Documents


0 download

DESCRIPTION

Các điều kiện hòa đồng bộ MFĐ vào lưới1. Cùng tần số 2. Cùng điện áp3 .Cùng tứ tự pha4Cùng góc lệch phaSau đây mình xin phân tích tại sao lại phải có các điều kiện đó:1 Nếu không cùng tần số: điều này quá nguy hiểm. Hãy tưởng tượng một cái động cơ mà có 2 tầnsố khác nhau truyền vào, nó sẽ chạy thế nào nhỉ, liệu có nhảy lên rộn ràng không? Và đã khôngcùng tần số thì làm sao mà gọi là 1 nguồn, lúc đó gần như tương đương 2 nguồn cấp cho tải2 Nếu không cùng điện áp: Điều này cũng không quá quan trọng nếu như điện áp gần tương đươngnhau. Tuy nhiên nếu điện áp chênh lệch quá lớn sẽ làm thay đổi đáng kể điện áp cung cấp của lưới==> có ảnh hưởng lớn đấy chứ. Và đặc biệt là sự quá độ thay đổi điện áp khi hòa MFĐ vào lưới, sự thay đổi bất ngờ của điện áp sẽ làm ảnh hưởng đáng kể đến các thiết bị. VD như một cái máy hàntự động mà điện áp giảm, thử hỏi sản phẩm làm ra lúc đó có đạt yêu cầu ko . Tất nhiên chẳngai ngu j đấu thẳng vào lưới những thiết bị như vậy.3 Cùng thứ tự pha ==rất quan trọng. Bạn cứ thử cộng vectơ của hai dạng A B C và A C B xemnguồn bây h sẽ ra cái j? :roll: Làm j còn ba pha sin lệch 120 độ nữa4 Cùng góc lệch pha: nghĩa là pha A của lưới và pha A của MFĐ cùng một góc lệch. Như thế thì khihòa đồng bộ công suất tổng hợp của lưới sẽ là lớn nhấtThân mến. Ai có giải thích cụ thể chính xác hơn xin post lên cho mọi người cùng học hỏi

TRANSCRIPT

Page 1: EB (25)-Từ điển

491

ANH VIEÄT ÑOÁI CHIEÁU ° ACB - air circuit breakers maùy caét khoâng khí

° ACR - automatic circuit recloser maùy caét töï ñoùng laïi ° ACE - area control error

° ADC - analog digital converter boä bieán ñoåi töông töï - soá

° AFC - automatic frequency control ñieàu khieån taàn soá töï ñoäng

° ALU - arithmatic and logic unit

° AGC - automatic generation control

° AMR - automated meter reading

ñieàu khieån phaân phoái coâng suaát töï ñoäng

ñoïc ñieän keá töï ñoäng

° ATS - automatic transfer switch thieát bò chuyeån nguoàn töï ñoäng

° ARS - autoreclosing schemes sô ñoà töï ñoùng laïi töï ñoäng

° AVR - automatic voltage regulator boä ñieàu chænh ñieän aùp töï ñoäng

° admittance relays rôle toång daãn

° amplidyne khueách ñaïi quay

° anti-pumping divice ° APGS - automatic protection group selection

boä phaän choáng ñoùng laäp ñi laäp laïi cuûa ACR löïa choïn nhoùm baûo veä

° apparent impedance

° AR - auto restoration

toång trôû bieåu kieán ño ñöôïc bôûi rôle, toång trôû

nhìn thaáy bôûi rôle

töï ñoäng taùi laäp löôùi ñieän

° back-up protection baûo veä döï tröõ (BVDT)

° balance point-reach, setting-tripping threshold ngöôõng taùc ñoäng

° block khoaù, caám

° biased differential relays rôle so leäch coù haõm

° bushing current transformer BI söù

° brushless exitation system heä thoáng kích thích khoâng choåi than

° by pass

° communication media

noái taét

moâi tröôøng truyeàn tin ° comparator

° CPS - communication port switch

boä so saùnh

khoùa lieân keát truyeàn tin

° CB-circuit breakers

° cold load pickup

maùy caét (MC)

doøng töï khôûi ñoäng

° current transformers

° communication processor

maùy bieán doøng ñieän (BI)

boä xöû lyù truyeàn tin

° DAS-data acquisition systems

° CAPM - control and protection module

heä thoáng thu thaäp döõ lieäu

khoái baûo veä vaø ñieàu khieån

° D-C components

° DAS - distribution automation system

thaønh phaàn 1 chieàu, khoâng chu kì

heä thoáng töï ñoäng phaân phoái

° Damping Winding cuoän caûn

° Dead line ° DFR - digital fault recorder

ñöôøng daây chöa mang ñieän boä ghi söï coá

° definite time current caracteristic ñaëc tính doøng ñieän-thôøi gian ñoäc laäp

Page 2: EB (25)-Từ điển

492

° differentical protection baûo veä so leäch (BVSL)

° directional comparison schemes sô ñoà so saùnh höôùng

° directional protection baûo veä coù höôùng

° distance relays rôle khoaûng caùch

° Directional comparison blocking scheme sô ñoà truyeàn khoùa so saùnh höôùng

° Underreaching tranfer trip scheme sô ñoà truyeàn caét döôùi taàm

° Overreaching transfer trip scheme sô ñoà truyeàn caét quaù taàm

° EHV-extra high voltage sieâu cao aùp

° electromechanical relays rôle ñieän cô

° EPROM-Erasable programmed ROM

° EEPROM-electrical erasable prograammable ROM ° E/F - earth fault

° FR - fuder recloser

chaïm ñaát

° EI-extremely inverse cöïc doác

° ELCB-earth leakage circuit breakers maùy caét choáng doøng roø

° EXP- exponential function haøm muõ

° extremely inverse time overcurrent relays rôle quaù doøng ñaëc tính thôøi gian phuï thuoäc cöïc doác

° FCO-fusse-cut-out caàu chì töï rôi

° fiber optic pilot system

° FR - fuder recloser

heä thoáng pilot caùp quang

ACR - ñaàu phaùt tuyeán

° field shorting circuit

° HMI - human machine interface

maïch daäp töø tröôøng

giao tieáp ngöôøi maùy

° impedance relays ° I & C - instrument and control

rôle toång trôû ñieàu khieån vaø ño löôøng

° inverse time current characteristic

° IED - intelligent electronic device

ñaëc tính doøng ñieän-thôøi gian phuï thuoäc

thieát bò ñieän töû thoâng minh

° instantaneous overcurrent protection

° instrument transformer

baûo veä quaù doøng caét nhanh

boä bieán ñoåi ño löôøng

° instantaneous operation taùc ñoäng töùc thôøi

° isochronous governor

° LA - loop auto mation

boä ñieàu toác coù ñaëc tính ñieàu chænh ñoäc laäp

töï ñoäng vaän haønh maïng kín

° LSB-least significant bit

° Loop auto mation timeout

thôøi gian thöïc hieän hieäu löïc LA

° LFC-load frequency control

° LBS - load break switch

thieát bò ñoùng caét taûi ° load damping factor heä soá chænh taûi

° local backup protection baûo veä döï tröõ taïi choã

° longitudinal differential protection

° LOP - loss of phase

baûo veä so leäch doïc

maát pha

° live line reclosing

° LTC - load tap changer

ñoùng laïi ñöôøng daây coù mang ñieän

boä ñoát ñaàu naác

° maximmum overcurrent protection baûo veä doøng ñieän cöïc ñaïi

Page 3: EB (25)-Từ điển

493

° MCBs-miniature circuit breakers

° MCCBs-moulded case circuit breakers

° magnetising inrush current doøng ñieän töø hoùa nhaûy voït

° memory boä nhôù

° measuring elements

° monitor

phaàn töû ño löôøng

giaùm saùt

° microwate pilot systems

° MiR - Mid-point recloser

heä thoáng pilot vi soùng

ACR giöõa FR vaø TR

° mullti-shot reclosing töï ñoùng laïi nhieàu laàn

° multiplexer boä choïn keânh

° mutual coupling hoã caûm ° non-unit schemes

° NPS - negative phase sequence

sô ñoà baûo veä khoâng toaøn phaàn

thöù töï pha nghòch

° overexcitation quaù kích thích

° OPAM-operational anylifier khueách ñaïi thuaät toaùn

° OCB-oil circuit breakers maùy caét daàu

° operating thresholds ngöôõng taùc ñoäng

° overvoltage relays rôle quaù ñieän aùp

° overreach quaù taàm

° PCB-printed circuit board

° P L C - p r o g ra mm mm m ba le lo g ic c o n tr o lle r - p o w e r lin e c a rr ie r

° permissive schemes sô ñoà cho pheùp °Permissive underreaching transfer trip scheme sô ñoà truyeàn caét, döôùi taàm cho pheùp

° PSM-relay plug setting multiplier boäi soá nhaân doøng ñieän ñaët

° potential transformers maùy bieán ñieän aùp (BU)

° power swing

° protocol gate way

° PF - phase fault

dao ñoäng coâng suaát

coång giao thöùc

chaïm pha

° power line carrier pilot systems heä thoáng pilot soùng mang taàn soá cao treân

ñöôøng daây taûi ñieän

° primary protection zones vuøng baûo veä chính

° primary governor boä ñieàu chænh toác ñoä turbine sô caáp

° RCD-resudual current devices boä phaän choáng doøng roø

° RCCB-residual current circuit breakers maùy caét choáng doøng roø ° RAM-random access memory

° REF - restrided earth fault

so leäch choáng chaïm ñaát

° ROM-read only memory

° reclaimtime thôøi gian boä töï ñoäng ñoùng laïi trôû veà sau khi ñoùng laïi thaønh coâng

° reset xoaù, giaûi tröø, hoài phuïc, trôû veà

° restraint elements phaàn töû haõm

Page 4: EB (25)-Từ điển

494

° rotating rectifier system

° RTU - remote terminal unit

heä thoáng chænh löu quay

thieát bò ñaàu cuoái

° REF - restricted earth fault relay

° SCAPA - supervisory control and data acquistion

rôle so leäch choáng chaïm ñaát

thu thaäp döõ lieäu vaø ñieàu khieån coù giaùm saùt

° SEC-sectionalizer dao caùch li phaân ñoaïn töï ñoäng

° secondary control ñieàu khieån thöù caáp

° section breakers maùy caét phaân ñoaïn

° semi-permanent

° SEF - sensitive earth fault

baùn thöôøng xuyeân

doøng chaïm ñaát beù

° shot laàn ñoùng laïi

° set ñaët, chænh ñònh ° single shot reclosing töï ñoùng laïi 1 laàn

° speed droop characteristic ñaëc tính ñieàu chænh toác ñoä turbine phuï thuoäc

° spill current doøng khoâng caân baèng

° static relay rôle tónh (baùn daãn, vi maïch...)

° static excitation system heä thoáng kích töø tónh

° switch-onto-fault-function chöùc naêng caét töùc thôøi maùy caét khi ñoùng vaøo ñöôøng daây ñang coù söï coá

° SFR - system frequency response ñaùp öùng taàn soá heä thoáng

° standby döï phoøng

° TMS - time multiplier setting trò ñaët thôøi gian

° TD-time dial setting trò ñaët thôøi gian

° T-C characteristics-time-current characteristics ° time synchronization source

ñaëc tính thôøi gian doøng ñieän nguoàn ñoàng boä thôøi gian

° time relays

° TR - tie recloser

rôle thôøi gian

ACR lieân keát

° transfer trip pilot protection baûo veä pilot truyeàn caét

° transverse differential protection baûo veä so leäch ngang

° trip caét

° underreach döôùi taàm

° undervoltage relays rôle ñieän aùp thaáp

° under excitation thieáu kích thích

° unbalanced currents doøng khoâng caân baèng

° unit-schemes sô ñoà baûo veä toaøn phaàn

° wire pilot systems heä thoáng pilot daây daãn phuï