.. ISO 11001:21100 AZIECA CERTIFIC ADO SEMBRANDO ISO 9000 20 de Octubre del 2004 At'n: Ing. Rodolfo Servin. c.c.p: Ing. Alfredo Cortes Silva. Estimado Ingeniero, de acuerdo a su solicitud tenemos el gusto de ofrecerle: Partida Cantidad Descri cion : 01 1 Pieza Medidor de flujo tipo V-Cone, para servlCIO: Medicion de flujo en linea de gas combustible. EI medidor cuenta con las siguientes caracteristicas: o Carrete de Acero al carb6n de 8"0. Cedula 80. o Diametro intemo 7. 636". o Conexi6n carrete brida 600# RF. o Posici6n del cono al centro del carrete. o Co no de acero inoxidable tipo 316. o Diametro del cono 6.82 pulgadas. o Tomas para presi6n baja yalta de 1/2"0 NPT. o Material de tomas de presi6n: Acero al carb6n. o Maxima presi6n diferencial282.1 pulgadas de agua . o Minima diferencial de 0. 11 pulgadas de agua. o Exactitud de +- 1 % del rango. o Repetibilidad de +- 0.1%. o Rangeabilidad de 50:1 . Para medir un rango de flujo de 1 MMSCFD hasta 50 MMSCFD. o Temperatura de operacion: 25°C. o Presi6n de operaci6n: 48 Kg/cm2. o De acuerdo a API 5.7. o Acabado ambiente humedo y marino, cumple con NACE MR-01-75 Ultima edici6n. o De acuerdo a API5L Gr.B ·SAW'. o No requiere partes de repuestos en 2 anos de operaci6n . o Marca: MfR OMETER (McCrometer Inc.) o Modelo : V-CONE serie VW o Embalaje apropiado para embarque a destino marino . o PRECIO UNITARIO: $13,200.00 D61ares + IVA. Documentos incluidos: Memoria de calculo de selecci6n , Diagramas de instalaci6n, Dibujos dimensionales, Certificado de materiales, Garantla de operaci6n , Hojas de datos rellenas, Manuales de mantenimiento, operacion y configuraci6n (en ingles), Lista de partes de repuesto, Certificado de pruebas de planta , Certificados de cumplimiento con NACE, Certificado de calidad, Protocolo de pruebas y calibraci6n, Certificado de Calibracion estandar de McCrometer. Corporaci6n Constructora Azteca SA de CV I Protectotank Draz Mir6n # 805 Col . Centro . c.P. 96400, Coatzacoalcosj Ver. Tel: (01921) 2121220/21 21504/2126517 Fax: (01921) 21 22451 e-mail: [email protected]m. mx sitio web: www.protectotan k.com.mx

Upload: destructor15

Post on 02-Oct-2014

233 views

Category:

Documents


9 download

TRANSCRIPT

Page 1: Medidor de Flujo

~ ~ ISO 1100121100AZIECA CERTIFIC ADO

SEMBRANDO ISO 9000

20 de Octubre del 2004

Atn Ing Rodolfo Servin ccp Ing Alfredo Cortes Silva

Estimado Ingeniero de acuerdo a su solicitud tenemos el gusto de ofrecerle

Partida Cantidad Descri cion

01 1 Pieza Medidor de flujo tipo V-Cone para servlCIO Medicion de flujo en linea de gas combustible EI medidor cuenta con las siguientes caracteristicas

o Carrete de Acero al carb6n de 80 Cedula 80 o Diametro intemo 7636 o Conexi6n carrete brida 600 RF o Posici6n del cono al centro del carrete o Cono de acero inoxidable tipo 316 o Diametro del cono 682 pulgadas o Tomas para presi6n baja yalta de 120 NPT o Material de tomas de presi6n Acero al carb6n o Maxima presi6n diferencial2821 pulgadas de agua o Minima diferencial de 011 pulgadas de agua o Exactitud de +- 1 del rango o Repetibilidad de +- 01 o Rangeabilidad de 501 Para medir un rango de flujo de 1 MMSCFD hasta 50

MMSCFD o Temperatura de operacion 25degC o Presi6n de operaci6n 48 Kgcm2 o De acuerdo aAPI 57 o Acabado ambiente humedo y marino cumple con NACE MR-01-75 Ultima edici6n o De acuerdo aAPI5L GrB middotSAW o No requiere partes de repuestos en 2 anos de operaci6n o Marca ~MfROMETER (McCrometer Inc) o Modelo V-CONE serie VW o Embalaje apropiado para embarque a destino marino o PRECIO UNITARIO $1320000 D61ares + IVA

Documentos incluidos Memoria de calculo de selecci6n Diagramas de instalaci6n Dibujos dimensionales Certificado de materiales Garantla de operaci6n Hojas de datos rellenas Manuales de mantenimiento operacion y configuraci6n (en ingles) Lista de partes de repuesto Certificado de pruebas de planta Certificados de cumplimiento con NACE Certificado de calidad Protocolo de pruebas y calibraci6n Certificado de Calibracion estandar de McCrometer

Corporaci6n Constructora Azteca SA de CV I Protectotank Draz Mir6n 805 Col Centro cP 96400 Coatzacoalcosj Ver Tel (01921) 212122021 215042126517 Fax (01921) 21 22451

e-mail cramosprotectotankcommx sitio web wwwprotectotankcommx

n ISO 90012000AZ I EC=A CERTIFIC4O()

CORPO lt l lU-- COlTIW ( TOIJ SEMBRAHDO ISO 9000

20 de Octubre del 2004

Partida cantidad Descripcion 02 1 Transmisor TotaUzador Integrador de f1ujo Marca Dynamic Fluid Modelo ECHART

para servicio de gas natural amargo y condensados con las siguientes caracteristicas

bull Disano compacta debido a que cuenta con modulo sensor digital multivariable integrado al computador para la medicion de temperatura presion asiatica y presion diferencial

bull Caja de Aluminio fo~ado libre de Cobre para areas peligrosas y ambiente corrosiv~ con recubrimiento de resina ep6xica y a prueba de explosion Clase 1 Div 1 Grupos B C Y D y clasificacion NEMA 7 Y NEMA 4X

bull Condiciones ambientales Temperatura de operacion de -40deg C a 85deg C bull Humedad relativa Hasta 100 sin condensacion bull Cuenta con ventana para visualizar la pantalla 0 display LCD sin abrir el instrumento bull Conexion eecbica Dos para tuberia conduit de tlPT bull Conexion a proceso De 1-18 NPT bull Material de la brida de proceso Acero Inoxidable 316 bull Alimentacion 6 a 28 VDC desde fuente extema 0 panel solar bull Consumo de energia 25 rnA a 12 VDC bull Opcion de alimentacion Por medio de panel solar de 5 Watts 6Vo~s

bull Pantalla Display tipo LCD grafica de 128X64 Pixeles8lineas de 16 caracteres bull Informaci6n desplegabe en pantalla La informacion se puede dasplegar en forma

grafica y alfanumerica Capaz de mostrar dos tendencias por cada pantalla y daspliega un total de 6 tendencias Los valores de las variables se despliegan uno tras otro en intervalos de nempo configurable en multiplos de 1 2 3 Y 4 segundos sin resbiccion en tiempo

bull Limites de temperatura (para la unidad con display) De operacion es de -40deg a 85degC y de almacenamiento es de -46deg C a 87deg C

bull Vibracion Desde 5 hasta 2000 Hz en cualquiereje segun procedimiento de prueba IEC 770 seccion 6214 Aprobado por SAMA PMC311

bull Cuenta con tecnologia basada en microprocesadores de 32 bits a 167 MHz de velocidad con memoria de programacion (EPROM) de 4MB memoria para datos de 2 MB para almacenamiento de informacion e historicos de hasta 64 dias

bull Reloj en tiampo real AnoMiesDialHoraMinuto bull Cuenta con bateria de respaldo de fitio para el reloj y para la memoria bull Una Entrada de frecuencia bull Entrada Digital 1entrada (+) digital de 7 a 24 VDC negativo a comun bull Una salida anal6gica de 4-20 rnA Resolucion 12 bits bull Una salida digital Tipo ONOFF 0 de pulsos (hasta 125 pulsosseg) bull Entradas de RTD Una entrada de RTD en el mOdulo multivariable y una entrada en

tablillas del computador Resolucion 24 bits

CO(QQracion Constructora Azteca SA de 0 I Protectotank Diaz Mir6n 805 Col Centro cP 96400 Coatzacoalcos Ver Tel (01921) 21212 2021215042126517 Fax (01921) 21 22451

e-mail cramosprotectotankcommx sitio web wwwprotectotankcommx

lt0 ~I ISO 90012000AZIECA CERTIFle ADQ

CORPORACIU~ c unwcrOR SEMBRANDO ISO 9000

scombustible 20 de Octubre del 2004

Partida cantidad Descripcion 02 1 bull Aislamiento Optico Cada entrada y cada salida esta foto-opticamente aislada con un

maximo de rechazo de modo comun en entradas y salidas de plusmn 250 VDC a tierra del chasis

bull Sistema de autodiagnostico Monitorea y alarma las siguientes condiciones

Estado del sensor multivariable en Presion estatica Presion diferencial y Temperatura

Estado de la entrada digital

Estado de las salidas de contacto

Estado de la entrada de frecuencia

Temperatura intema

Valores de voltaje intemo y de Ia bateria

bull Comunicaciones Un puerto serial RS232 0 RS485 velocidad de transmision de 1200 a 9600 BPS protocolo MODBUS RTUASCII Y un puerto serial RS232 velocidad de transmision de 1200 a 9600 BPS protocolo MODBUS RTUASCII

bull Elementos primarios de medicion compatibles Diferencial Placa de orificio V Cone Wedge Annubar Venturi De pulsos Turbinas PO Vortex Ultrasonicos Masicos

bull Unidades de Ingenierla US y Metrico bull Ecuaciones para caiculo de flujo AGA 3 API 143 AGA 7 AGA 9 Y AGA 8 Metodos 12

y detallado API 56 API5 API 2540 API11-2-1 API11-2-2 Todos los calculosreporteshist6ricosalgoritrnos etc En acuerdo a los lineamientos del API Capitulo 211

Sensor Multivariable MOdulo multivariable 3 en 1 modelo 205 de Rosemount Cuenta con Ia tecnologia de oolda de capacitancia para sensar la presion diferencial sensor piezoresistivo con silicon para sensar la presion estatica y una entrada para RTD que se encarga de sensar la temperatura Sensor de Presion Diferencial Rango desde 0-250 pulgadas de H20 Con una exactitud del plusmn 0075 del span para spans desde 11 a 101 del URL que incluye los efectos de linealidad histeresis y repetibilidad

Sensor de presion absolutal manometrica Rango desde 0-3626 PSI Con una exactitud del plusmn 0075 del span para spans desde 11 a 101 del URL que incluye los efectos de linealidad histeresis y repetibilidad

Sensor temperatura de proceso Es compatible con cualquier tipo de RTD de Platino100 Ohms de 23 0 4 hilos Con un rango de -40a C a 6490 C con una exactitud de plusmn 056deg C que incluye los efectos de linealidad histeresis y repetibilidad

Corporacion Constructora Azteca SA de 01 I Protectotank Draz Miron 80S Col Centro CP 96400 Coatzacoalcos Ver Tel (01921) 212122021215042126517 Fax (01921) 21 2 24 51

e-mail cramosprotectotankcommx sitio web wwwprotectotankcommx

m ISO 9001 2000 CERTIFIC AOQ

20 de Oetubre del 2004

Partida Cantidad Oeseripelon 02 1 bull Materiales de eonstrueeion del modulo multivariable

Conexiones a proeeso ~NPT con distaneia entre centros de 218 Partes humedas Diafragma de Hasteloy C (para manejo de gas amargo NACE

MR-01-75) Bridas Acero Inoxidable 316 Anillos de las partes humedas De teflon con alma de vidrio Partes no humedas EI fluido de lienado es Aeeite de silicon anilos de Buna N

Incluye

Un kit de montaje de Acero Inoxidable 316 para pedestal de 2 Un manifold de 5vias de Acero Inoxidable 316 de de diametro para una presion

maxima de 10 000 psi (700 Bar) Software de programaeion gratuito (Ambiente Windows) Embalaje apropiado para embarque a destino marino Documentos ineluidos Certificado de materiales Garantia de operaeion Hojas de

datos rellenas Manuales de mantenimiento operacion y eonfiguracion (en ingles) Lista de partes de repuesto Certifieado de pruebas de planta Certifieado de ealidad Protocolo de pruebas y ealibraeion Certifieado de Calibraeion de la planta

Precio Unitario $ 530000 usn +IVA

Terminos comerciales 1 Validez de la oferta 90 dfas 2 Tiempo de entrega 120 dfas 3 Forma de pago 30 dfas presentacion factura 4 Garantfa de caUdad 12 meses de operacion 018 despues del embarque 5 Precios fijos en dolares arnericanos + NA 6 Embalaje adecuado tipo marino 7 LAB su almacen PEP Cd Del Carmen Campeche

1 Atentam nte

Ing Carlos Manuel Ramos Yeh Corporaci6n Constructora Azteca SA de cv

cramosprotectotankcommx Auxiliar de gerencia

Corooracion Constructora Azteca SA de CV I Protectotlnk Diaz Miron 805 Col Centro c P 96400 Coatzacoalcos Ver Tel (01921) 212122021215042126517 Fax (01921) 21 2 2451

e-mail cramosprotectotankcommx sitio web wwwprotectotankcommx

-- - -

- - -

- - -

V -Conereg Preliminary Sizing

Description ~-cone 8 CSS316 Cone S80 ANSI WN CL600 RF

1000 Fa - aPE D67e-06 d 67e-06

Pv

HL I 210 inWC

~ Entered value Table based on one flow condition (P T Z k ) V25 Version 41

Record Start Date 10-18-2004

Print Date 10-20-2004 ~ McOOMEIER L _ _ _ _ _

By Corporacion Constructora Azteca SA de CV

Fluid

Serial Fluid State

End User Job Ref

IndustryModel

Tag I Gas Combustible r-

f--shy

VW08FF 16N-BAZ

NATURAL GAS 174mw

GAS

CPTG ATASTA

PEP

Note r-085

I kgcm2Gr30 degc

2444 Ibft3

1135e-02 cP -

p

G 06008

Z 09172

Y 09918 c-- - - shy

k I 1302

8573 Cp

Mw 17400

14 696 psi -

OF60000

I 09979 I I 14696 psiPbaro

Pc I 66720 psi

of-11657Tc

----------------------------------------------------------------~

q max Flowrate 50000000 SCFD

6977e+06

34 22 fps

28208 inWC

01110 inWC

7636 in

6820 in

04498

50

McCrometer Cal

Third Party Cal Re max Reynolds

Dye Pen Exam V max Velocity

Hydro Test ilP max Dp

ilP min Dp X-Ray Exam

D Meter 10 Mag Part

d Cone OD PMI

p Beta Ratio CMTR Copies

Turn Down Application Eng

I--- shy

CMRY

Velocity Gas Exp ilP Flowrate

Re fps Y inWC SCFD

1 6977e+06 3422 09918 2821 50000e+07

2 6217e+06 3049 09935 2232 44556e+07

3 5458e+06 2676 09950 1715 39111e+07

4 4698e+06 2304 09963 1267 33667e+07

5 3938e+06 1931 09974 8885 28222e+07

6 3178e+06 1559 09983 5777 22778e+07

7 241ge+06 1186 09990 3341 17333e+07

8 165ge+06 8136 09995 1570 1188ge+07

9 8993e+05 4410 09999 4610 64444e+06

10 1395e+05 06843 1000 01110 10000e+06

File Gas Combustible ATASTAv25

yeoNE reg CONFIGURATION SHEET

PRECISION TUBE SERIESMODELVW (H)

ANSI 8165 Weld Neck Raised Face Flanges - Class 600 or 900

DESCRIPIION AND GENERAL PERFORMANCE SPECIFICATIONS The V -Conereg flowmeter is a patented differential pressure type flow measurement device A cone is positioned in the center of the pipe to increase the velocity of the flowing fluid and create a differential pressure This pressure difference can be measured and used to accurately interpret flowrate Two taps are provided on every V -Cone to allow sensing of the high and low pressures A typical V-Cone application can follow these general performance specifications bull Accuracy up to plusmn05 of rate Model VW Bulletins

ANSI 8165 Weld Neck RF Flanges 24509-35 Class 150 or 300

bull Repeatability plusmnO J bull Turndown 10 1 24509-36 Class 600 or 900 bull Standard Betas 045 through 085 24509-37 Class 125 or 250 bull Headloss Percentage of differential pressure produced varies with beta ratio bull Installation Typically 0-3 diameters upstream and 0-1 diameters downstream Each V -Cone is sized for the intended a Ii cation S ecific erformance ratin s must be obtained throu

MODEL VW(H) DIMENSIONS

H L 2 1 8 (Note 2) B1- ~WE-D DC

~ I -rr --- - T - III

Lk-l - -- -- c-ttt- -- - -- -- - -- -

- - --- --- ---

I

--------------A------------~-t I A lor to 1 1lor to 24

DIMENSION TABLE

I

Size ANSI B165 Class 600 ANSI B165 Class 900 Stainless Carbon

0 E (Note 2) A (Note 1) B A(Note 2) B C (Note 2) C (Note 2)

inch inch mm inch mm inch mm inch mm inch mm inch mm inch mm NPT

y 1225 3112 563 1430 1288 3272 594 1509 0622 158 - - 084 213 Y Y 1263 3208 582 1478 1363 346 2 632 1605 0824 209 - - 105 267 Y 1 1300 3302 601 1527 1388 3526 644 1636 1049 26_64 gtshy - - 1315 334 Y 1Y 1550 3937 576 1463 1650 419 1 626 1590 1645 4178 - - 19 483 Y 2 1763 4478 631 1603 1988 5050 744 1890 2104 5344 - - 2375 603 )I

2)1 1800 4572 650 1651 2000 5080 750 1905 2504 6360 - - 2875 730 Y

3 2025 5144 663 1684 2175 5525 738 1875 3104 7884 - - 35 889 )I

4 2375 6033 788 2002 24 75 6287 838 2129 4090 1038 - - 45 114 Y

6 3100 7874 875 2223 3275 8319 963 2446 6065 1541 6065 1541 6625 168 Y

8 3600 9144 1001 254 3 3825 971 _6 1113 2827 7981 2027 7981 2027 8625 219 )I

10 3950 1003 1076 2733 4200 1067 1201 3051 1002 2545 1002 254 5 1075 273 Y

12 4175 1060 1113 2827 452 5 1149 1288 327 2 1200 3048 1194 3033 1275 323 Y

14 4225 1073 1213 3081 4600 1168 1400 3556 1325 336 6 1313 3335 14 355 Y

16 4325 1099 1263 3208 4625 1175 1413 3589 1525 3874 1500 3810 16 406 Y

18 4575 1162 1288 3272 4925 1251 1463 371 6 1725 438 2 1725 4382 18 457 Y

20 5025 )11276 11 1313 3335 5475 1391 1538 3907 1925 4890 1925 4890 20 508 Y

24 6325 1607 1763 4478 7025 1784 2113 536 7 2325 5906 2325 5906 24 609 Y 1 Overall length (A) tolerance vanes With line size jYto 1 plusmn18 (plusmn4mm) 1 jYto 10 plusmn316 (plusmn6mm) 12 to 24 plusmn14 (

2 Typical values shown

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-68111 Fax (909) 652-3078$ MQ[)MEIER Web Site httpWlNwmccrometercom e-mail infomccrometercom

Lit24509-36 Rev 146-00 copy2000 by McCrometcr Inc Printed in USA

I bull

CONFIGURAIiON SHEET MODEL NUMBER CONFIGURATION VW(H)

Pipe Size Materialsj Schedule FittingsEnd Connections

VW Q A 10OA S304V2 JLj CL 600 RF WN LtJ NPT

OB L S304L B 20 17 CL 900 RF WN S Socket 01 1 A S316L C Bored

Scvcmllypcs of ICS Tube amp Flanges 0 StdOC 1V2 ~ fittings aV01ilablc

2 40 00

S304 Cone Support amp Couplings E02 Epoxy Coated Blue (excluding cone) F 80

03 2V2 3 r-u CS Tube amp Flanges J 100

04 4 S304 Cone Support amp Couplings 120K jOther materials can include6 Coating Painting Per Customer Req 14006 L

-shy HASTELLOY C-276 S321H8 G 160 DUPLEX 2205 INCONEL 625

08 10 XXS

CHROMEMOLY P22PII 10 H

10S MONEL K400K500

12 M12 14 P XS

CARBON STEELS 14

16 -- shy

A350 A333 AP15L A 106B 16

18 20 18

20 24~

Example VW10AE16N V-Cone 10 inch line size S316L schedule 40 pipe ANSI CL 600 RF WN flanges V2NPT fittings

Type

STANDARD PIPE SCHEDUIpoundS Stainless Steel Carbon Steel

Size Std Size Std to 4 C

6 to 10 E 12 and up 0

6 to 16 18 and up

E 0

Pipe up to 8 utilizes seamless pipe Above 8 is welded pipe

ABBREVIATIONS ASME American Society of Mechanical Engineers NPT National pipe taper SS Stainless steel RF Raised Face CS Carbon steel WN Weld Neck

Technical questions can be answered through a local representative or through our application engineers

REPRESENTED BY

MANUFACTURING STANDARDS McCrometers welders and welding procedures are qualified in accordance with ASME Section IX All meters are visually inspected for weld defects Specific customer requirements can be complied with upon request

The welding can be in accordance with

bull ASME Section VIII

bull ASME B311

bull ASMEB313

Non-destmctive testing can include

bull Hydrostatic Pressure Testing

bull Penetrant Examination

bull Radiographic Examination

bull Positive Material Inspection

bull Magnetic Particle Examination

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-6811 Fax (909) 652-3078 Web Site httpwwwmccromelercom e-mail infomccrometercom

Lit24509-36 Rev 146-00 copy 2000 by McCrometer IncPrinted in USA

~----------------------~---------------------------------------------------------------------------

V -Cone Installation Guide Upstream and Downstream Minimum Straight Pipe Run Requirements

For Liquid Metering and Gases at a Reynolds Number (Re) Value Less Than or Equal To 200000

For fl greater than or equal to 065 add ID

Obstruction DownSize Range Up Stream Stream

I Elbow OD

2 Elbows

OD

OD OD

Tees OD OD Not Preferred ValveAll Sizes Butterfly Valve (control valve) DownstreamPosition

3D 3D

Butterfly Valve (shutoff valve) 3D OD

Full port Ballvalve (shutoff) OD OD

Heat Exchanger (Depends on Type) OD OD

Expander (067D to D) over a length ID ID of 2SD

Reducer (3D to D) over a length of ID ID 3SD

Note The meter and adjoining pipe should have equal IDs

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-6811 Fax (909) 652-3078 ~ MCOOMEIER Web Site http wwwmccrometercom e-mail infomccrometercom

Lit24S09-21 Rev 10102-04 copy2004 by McCrometer InclPrinted in USA

Product Data Sheet DAN-GFM-DS -21-rev0404 ( )

April2004 SeniorSonic with Mark TM Electronics

- SeniorSonic The Daniel SeniorSonic Gas Flow Meter with Mark IWM Electronics saves you time and money Lost and unaccounted for gas is reduced by exceptional low and high flow accuracy and linearity throughout the calibrated flow range Time is saved by a best-in-class audit trail Mark III Electronics can pinpoint alarms events and configuration changes in a matter of seconds Best of all operating the Daniel SeniorSonic gas flow meter is easy with the Windowsreg based Daniel Customer User Interface (CUI) software

Features middot Excellent long-term performance

Velocity Range Most sizes are rated to performa at 100 fps middot Full electronic audit trail (exceeds API 211) Over-range of up to 125 fps and in some cases beyond 125 middot Exceptional low and high flow performance

middot Bi-directional multi-point calibration coefficients fps in emergencymiddot situations and without transducer failure

middot Rangeability exceeds 50 1 with calibration Availability is limited by line size and ANSI rating Visit middot ANSI 30060090015002500 versions wwwdanielcomseniorsonic for additional information middot Extractable transducers (For all sizes) middot Minimum upstream piping requirements Meter specifications

Gas temperature -4 to +212deg F (-20 to +100deg C) Easy to learn and use CUI software features Operating pressure range 150 - 3750 psig middot Comprehensive monitor screen (1030 - 25855 kPa) Consult factory for lower and middot Field start-up wizard higher pressure applications middot Calibration wizards (analog and frequency) Flanges RF for 3001500 RTJ for 6002500 middot Flow calibration configuration wizard middot Audit 1 alarm 1history retrieval Power DC version - 1224 (11-36) VDC 6 watts maximum middot Digital waveform viewing middot Maintenance log summary in ExcelI Environmental middot Built-in AGA 10 SOS calculator Operating temperature -40 to +149deg F (-40 to +65deg C) middot Automatic file naming Operating relative humidity up to 95 non-condensing middot Trending of maintenance logs Storage temperature -40 to +185 0 F (-40 to +85 0 C) middot Configuration comparison with exception summary middot Remote dial-up support and Ethernet support Typical Applications middot Unlimited meter directory support middot Custody transfer

middot Power plants Specifications middot Large industrial users

Electronic unit middot City gates Communication protocol Modbus RTUASCII amp TCPIIP middot Production Two serial RS-232485 ports and Ethernet middot Underground storage sites Communication speed Up to 115 KBPS middot Offshore Frequency outputs Four Frequency range 0-10005000 Hz Safety classifications Digital output Selectable (up to four for data valid or flow UL listed for use in Class I Division 1 Group D hazardous

direction) locations in both the US and Canada (UL E152246) Calculation update time Configurable for 14 and 1 second CE marked to ATEX directive (949EC ) (pending)

Certified to Eex d ia liB T4 to standards EN 50014 EN 50018 Accuracy and EN 50020 (pending) Flow calibrated accuracy plusmn 01 (Relative to lab) Absolute accuracy Including lab uncertainty about 03 Repeatability plusmn 02 of reading for Ot to Omax

-- - tI II~ EMERSON ~-----

wwwdanielcom

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Recommended Ma~jum Flow Velocity Meter Size J Meter Size Metric Max Inches Max ftI~ m tris

4 100 100 30 6 100 150 30 8 100 200 30

10 80 250 24 12 80 300 24 16 85 400 26 20 85 500 26 24 85 600 26 30 70 750 21 36 70 900 21

Dimensions These measurements are meant only as an aid in the design of metering systems Consult Daniel engineering drawings prior to construction

Typical 600 ANSI Meter with 45 Degree-Angled Transducers Overall End- Flange Approximate Overall End- Flange Approximate

Meter Size To-End Diameter Weight To-End Diameter Weight (Inches) (Inches) (Inches) (Pounds) (Millimeters) (Millimeters) (Kilograms)

4 2900 1075 370 737 273 168 6 2950 1400 460 749 356 209

8 3150 1650 650 800 419 295 10 3400 2000 885 864 508 402 12 3544 2200 1075 900 559 489 16 4400 2700 1955 1118 686 889 18 4531 2925 2800 11sect1 743 1273 20 5062 3200 30Z5 12amp6 84~ 1398

0 4 5862 3700 404~ 1489 940 1839 30 6700 4450 4925 1702 1130 2239 36 7350 5175 6425 1867 1314 2920

()l p l ( C flO

bull I iY0

e

Page 2

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 60 F and gas composition These values are intended to be a guide in Contact Daniel engineering for a specific application

_ Flow Rates (JIISCFHl Basea Upon 100 ftls PSIG 4 6 8 10 12 16 20 24 30 36 100 247 561 971 1532 2174 3432 5398 7807 12607 18154 200 468 1065 1845 2908 4127 6515 10248 14822 23935 34467 300 696 1584 2743 4325 6137 9690 15240 22043 35596 51258 400 931 2118 3668 5782 8206 12955 20377 29472 47593 68534 500 2667 4619 7282 10334 16315 25661 37114 59934 86305 600 1421 3232 5597 8823 12522 19770 31095 44973 72626 104582 700 1676 3813 6602 10409 14772 23322 36682 53055 85677 123374 800 1938 4409 7635 12036 17082 26968 42417 61349 99070 142661 900 2207 5021 8694 13706 19452 30710 48302 69861 112816 162455 1000 2482 5646 9777 15414 21875 34536 54320 78565 126872 182696 1100 2763 6286 10885 17161 24355 38451 60478 87471 141254 203405 1200 3050 6939 12015 18943 26883 42443 66756 96551 155917 224521 1300 3341 7602 13164 20753 29453 46500 73137 105781 170822 245983 1400 3637 8274 14327 22587 32055 50608 79599 115127 185915 267718 1500 3935 8953 15504 24442 34688 54765 86137 124583 201184 289706 1600 4235 9635 16685 26305 37331 58938 92700 134076 216515 311781 1700 4536 10321 17871 28175 39986 63128 99291 143608 231908 333948 1800 4836 11002 19052 30036 42627 67298 105850 153094 247227 356006 1900 5134 11681 20226 31888 45255 71448 112376 162534 262471 377958 2000 5429 12350 21386 33716 47849 75543 118818 171851 277516 399623

Flow Rates (MIfIISCFfJ) Based Upon 100 ffls PSIG 4 6 8 10 12 16 20 24 30 36 100 59 135 233 368 522 824 1295 1874 3026 4357 200 113 256 443 698 990 1564 2459 3557 5744 8272 300 168 380 658 1038 1473 2326 3658 5290 8543 1230 400 224 508 880 1388 1969 3109 4890 7073 1142 1645 600 282 640 110~ 1748 2480 3916 6159 8907 1438 2071 600 342 776 1343 2118 3005 4745 7463 1079 1743 2510 700 403 915 1685 2498 3545 5597 8804 1273 2066 2961 800 466 1058 1832 2889 4100 6472 1018 1472 2378 3424 900 531 1205 2087 3289 4668 7370 1159 1677 2708 3899

1000 597 1355 2346 3699 5250 8289 1304 1886 3045 4385 1100 665 1509 2612 4119 5845 9228 1451 2099 3390 4882 1200 734 1665 2884 4546 6452 1019 1602 2317 3742 5389 1300 804 1824 3159 4981 7069 1116 1755 2539 4100 5904 1400 875 1986 3438 5421 7693 1215 1910 2763 4462 6425 1500 947 2149 3721 5866 8325 1314 2067 2990 4828 6953 1600 1019 2313 4004 6313 8960 1415 2225 3218 5196 7483 1700 1091 2477 4289 6762 9597 1515 2383 3447 5566middot 8015 1800 1164 2641 4572 7209 1023 1615 2540 3674 5933 8544 1900 1235 2803 4854 7653 1086 1715 2697 3901 6299 9071 2000 1306 2964 5133 8092 1148 1813 2852 4124 6660 9591

Calculating meter capacity To calculate a volume rate for a given velocity multiply the capacity in this table by the desired at the pressure and divide the answer by 100 Example Determine the hourly flow rate al 70 fps for an 8 inch meter operating at 800 psig Volume =7635 MSCFH Velocity 70 Answer = 763570100 = 5344 MSCFH

Pa~e 3

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 20 F and gas composition These values are intended to be a guide In Contact Daniel nee ring for a application

Flow RateS (IASOFH) Based UppJ1 30 mls Schedule 40) kPag 4 6 8 10 12 16 20 24 30 36 1000 967 2201 3811 6007 8527 1346 2117 3062 4945 7121 1500 1422 3234 5600 8827 1253 1978 3111 4500 7267 1046 2000 1885 4289 7428 1171 1662 2624 4127 5969 9639 1388 2500 2359 5367 9294 1465 2079 3283 5164 7469 1206 1737 3000 2843 6468 1120 1765 2506 3956 6223 9000 1453 2093 3500 3337 7592 1315 2072 2941 4644 7304 1056 1706 2457 4000 3841 8739 1513 2385 3386 5346 8408 1216 1964 2828 4500 4356 9910 171S 2705 3840 6062 9535 1379 2227 3207 5000 4881 1111 1923 3031 4303 6793 1068 1546 2495 3593 5500 5417 1232 2134 3364 4774 7538 1186 1715 2769 3987 6000 5962 1 3702 5255 8297 1305 1887 3048 4389 6500 6517 1483 2568 4047 5745 9070 1427 2063 3332 4798 7000 7082 1611 2790 4398 6243 9856 1550 2242 3621 5214 7500 7656 1742 3016 4754 6748 1065 1676 2424 3914 5636 8000 8238 1874 3246 5116 7262 1146 1803 2608 4212 6065 8500 8828 2009 3478 5482 7782 1229 1932 2795 4513 6499 9000 9425 2144 3713 5853 8308 1312 2063 2984 4818 6939 9500 10028 2281 3951 6227 8839 1396 2195 3175 5127 7382

10000 10636 2420 4190 6604 9375 1480 2328 3367 5437 7830

Flow Rates (IANSOND) Based Upon 30 mls (Scnedule 40) PSIG 4 6 8 10 12 16 20 24 30 36 1000 0232 0528 0915 1442 2046 3231 5082 7350 11869 17091 1500 0341 0776 1344 2119 3007 4748 7468 10801 17441 25116 2000 0453 1029 1783 2810 3989 6297 9904 14325 23133 33311 2500 0566 1288 2231 3516 4991 7879 12393 17924 28946 41682 3000 0682 1552 2688 4237 6014 9495 14935 21600 34882 50230 3500 0801 1821 3155 4973 7059 11145 17530 25354 40943 58958 4000 0922 2097 3632 5725 8126 12830 20179 29186 47131 67869 4500 1045 2378 4119 6492 9215 14549 22883 33097 53447 76963 5000 1171 2664 4615 7275 10326 16302 25641 37086 59889 86240 5500 1300 2957 5121 8072 11459 18091 28454 41154 66458 95699 6000 1431 3254 5637 8885 19912 31319 45298 73150 105336 6500 1564 3557 6162 9713 13787 21767 34236 49517 79964 115148 7000 1700 3866 6696 10555 14982 23653 37203 53808 86893 125126 7500 1837 4179 7239 11410 16196 25570 40218 58168 93934 135265 8000 1977 4497 7789 12278 17428 27515 43277 62592 101078 145553 8500 2119 4819 8347 13157 18676 29485 46376 67075 108318 155978 9000 2262 51 8912 14047 19939 31479 71611 115642 166524 9500 2407 5474 9482 14945 21214 33492 52679 76191 123038 177175

10000 2553 5805 10056 15851 22500 35522 55871 80808 130494 187911

Calculating meter capacity To calculate a volume rate for a given velocity the capacity this table by the desired velocity at the operating pressure and divide the answer 100 Determine the hourly flow rate at 30 mps for an 8 inch meter at 4500 Volume 1716 Velocity 10 Answer 17161030 5719 MSCMH

Product Oata Sheet DAN-GFM-DS-21-rev0404 April 2004

The drawings below represent recommended piping lengths for various flow conditioners when installed with the Daniel SeniorSonic flowmeter If shorter lengths are used there may be an increase in flow measurement uncertainty

Piping Recommendation For SeniorSonic With No Flow Conditioner

1~~--------------------200 -----------------------~

Q----I__------shy~

J ~~f --M-I-middotn-im-~-~-p-iP-i-n-g-R-e-c-o-m-m-e-n-a-a-tl-o-n-F-o-r-S-en-I-o-r-S-o-n-ic-W-it-h-D-a-n-ie-l-p-r-O-fi-le-r-o-r-C-p-~-5-0-E~-F--o-w-c-o-n-d-itl-io-n-e-r--

1 00 middot -2 o~o ~1gt

[ _____ ---Al11~ ----- =ul [II I

I 0 0 a It Minimum Piping Recommendation for Bimiddotdirectional SeniorSonic

with Daniel Profiler or CPA 50E Flow Conditioner

~------- 100 ------t ~------- 100 ----~ - 50---shy

3middot 50

-- 50 ---shy

3middot 50

~ -

A WARNING Do not operate this instrument in excess of the specifications listed Failure to heed this warning could result in serious injury andor damage to the equipment

Page 5

---- - --- _ --- ----------------- -------------------------shy

--iI

-------~~--------1

----~----------------I _____________________I

----~------~----__i _____bullmiddot________ ----__i

____________shy____~__i

____________________---i __________________

_________shy__________~~

~ I ~

I

~

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

8

10

12

16

20

24

30

36 r

ANSI Class 300 600--~------------------------i

900__________----__------__------i 1500

-------------------------------~ Flange Raised Face (RF) _________________-_------j

Ring Type Joint (RTJ)___---------__bull-_____Imiddot

Materials Standard ~----~~--~----~--------~~ Stainless Steel

DJplex --~--------------------------~----~ _________________________--____~__

Device Type

Electronics

Transducers

Meter Size (Inches)

Daniel Ultrasonic Model Number Selections ES-21055 RevW

SeniorSonic (4-Path) ---------------1 JuniorSonic (1~Path) ------------1 JuniorSonic (2-Path) ______________

Mark II UL 24VDC 4-20rlA 3NPT

Mark UL 24VDC 1middot5VDC 3NPT ---------------------1 Mark CENaEC 24V DC 4-20mA M20 --------------_--__1

Mark IICB-JELEC24VDC1-SVDCM20

Mark II ClNELEc 24VDC 4-20mA M20 Rerrote

Mark II CENELEC 24VDC 1-5VDCM20 Rerrote

MarkU UL 24VOC4-20mA 3NPT Rerrote_

Mark II U~ 24VDC l-SVPG 3NPT Rerrote

Mark IIIUL 34 NPT

Mark III UL 34NPT Rerrote

TmiddotSlo T-12

4

middot 6

Page 6

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Systems Daniel Measurement and Control is the industry leader in designing constructing and commissioning of complex oil and gas metering systems to exacting standards

This global organization offers decades of petroleum fiscal flow measurement application experience Customers rely confidently on Daniels Systems Group international fabrication facilities customized engineering and its successes in field-testing and support From the simplest single-stream skid to complex on-site installations Daniel Systems delivers both natural gas and liquid petroleum tumkey applications Daniel Systems designs constructs and commissions the metering project blending up-toshythe-minute technology with decades of understanding what customers need and expect

Components of a Daniel Systems installation typically include meters valves provers flow-control instruments instrumentation and read-out equipment and process management components

Computer software and hardware are integrated with the measurement system Standard calculation methods include AGA3 (now API-MPMS-143) ISO 5167 AGA578 AGA9 and the API Manual for Petroleum Measurement Standards

Daniel DMSS-2000 Supervisory Control Systems utilize a sophisticated Graphical User Interface database server and a dedicated PLC for the metering skidMOV interface Redundancy is often used for custody transfer systems andor when system integrity is essential

A dedicated Project Manager and Project Team are assigned to each measurement system project This team is responsible for overall system design and project construction from start to finish A separate internal QAQC group reviews all design detailS inside and outside fabrication assembly and system testing

Whether it is a pipeline offshore production facility or a loading facility for ocean-going tankers the Daniel Systems group is a proven single-source solution for customers throughout the world

Page 7

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Daniel Measurement Services Daniel Measurement Services takes pride in being there after needs arise with the right solution for customers with gas and liquid fiscal flow measurement applications

Around the clock and around the world Daniel Measurement Services has experienced highly qualified people prepared to help customers who need assistance with the following

middot Start-up and commissioning middot Preventive maintenance middot Product repair I upgrades middot Project management and integration middot Meter Tube inspection and recertification middot Remote diagnostics middot Warranty Plus middot Technical training

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880

Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337

Stirling Scotland - UK Middle East amp Africa T +4401786433400 F +44 01786433401

Singapore - Asia Pacific T +65-6777-8211 F +65-6770-8001

USA Toll Free 1-888-FLOW-001 wwwdanielcom

Daniel is a whOlly owned subsidiary of Emerson Electric Co and a division of Emerson Process Management The Daniel logo is a registered trademark of Daniel Industnes tnc The Emerson logo is a trademark and service mark of Emerson Electric Co Brand mark listing are marks of one of the Emerson Process Management family of companies All other marks are property of their respecl ive owners The Daniel UltraSonic Gas Flow Meter including Mark III electronics is covered by US Patents 598330 and 4646 575 and patents pending The contents of this publication are presented for information purposes only and while effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or thel( use or applicability Daniel does not assume responsibility for the selection use or maintenance of any Daniel product Responsibility for proper selection use and maintenance of any Daniel product remains solely wilh the purchaser and end-userAII sales are governed by our terms and conditions which are available upon request We reserve the right to modify or improve the designs or specification of our products at any time without notice

-- -~J ~~--------- EMERSON bull ~ I

copy2004 Daniel Measurement and Control Inc All rights reserved Printed in the USA DAN -GFM-DS-0221-rev0404

reg DAN-3MT-3M-0801 -~I August 2001_-shy

3 SectioQltandProfiler Meter Tubes ~ Pf~6 5 ~~ IrMimiddot~

Instruments You Can Trust Daniel Meter Tubes are more than just fabricated pipe with an orifice fitting They are accurate dependable instruments because of Daniels dedicated approach to quality Extra steps taken during every phase of meter tube design and production separate Daniel Meter Tubes from all the rest

The Daniel 3 section meter tube is available with any style Senior or Junior orifice fitting Simplex plate holder or orifice flanges The assembly contains an inlet spool of the minimum length prescribed by the 143 standard The second section begins with a concentric flange mounted tube bund=1 leetln9 the 2000 API 143 requirements and a W thick spacer plate to ease tube removal for inspection The 04~r end of section 2 conshytains the orifice flange or fitting The third or downstream section follows and contains 2 branchOonnections and is extra long to allow for the addition of extra branch conshynections in the field If desired The standard meter tube has flanged outer ends Other end connections are avaUable on request

Inspectionffesting= Daniel maintains rigid inspection procedures during manufacturing of meter tubes Micrometer and internal surface roughness readings are recorded and supplied with each meter tUbe Customer or third party inspectors are welcome to verify these readings Radiography of welds is another service that is available

Fabrication Fabrication of your instrument Includes attaching the orifice fitting to the meter tube to make an integral primary measuring element For welding operashytions Daniel uses automatic welding machines and rotatshying positioners Highly skilled code qualified welders are employed to tum out highest quality on each job Special internal jigs and fixtures are used to insure smooth Inlet and outlet surfaces without steps or offsets All welds receive expert grinding by experienced craftsshy

men X

cl

-

gt shy

~

-

J ~

Features bull Dowel pin alignment close tolerance maleffemale

flange or knock out dowel pins insure that the bores of sections two and three are matched without offsets

One 1h and one 0 branch connection on the downstream for thermowell or other uses standard

Beveled flanged or reduced ends as well as any available weld fitting can be furnished on the ends of the tubes

Hydrostatically tested after manufacture

Each orifice fitting is tested for tap hole and orifice plate seal integrity after the meter tube has been pressure tested

Material Selection Daniel uses special cold drawn seamless tubing or honed pipe in the fabrication of meter tubes The strict reqUirements for intemal roundshyness and surface finish preclude the use of standard commercial pipe in most cases Daniel maintains a large inventory of this special pipe to rapidly complete your order

LT

EMERSON~ ltocess Management

~~------------------------------------------------------------~------------------------------

Raised Face Weld neck

NA

3M-30RW

3M-60RW High Pressure

3M-90RW 3M-150RW 3M-250RW

DAN-3MT-3M-0801 August 2001

3 Section Meter Tube Catalog Numbers 2-12 with Senior Fitting 10 amp 12 with Junior Fittina

~

Pressure Rating

150

Flange by Weld

(Flangnek)

3M-011

Flange by Flange

(Flanged)

3M-101

Weld by Weld

(Weldnek)

NA

Flange by Weld

(Flangnek)

3M-021

Flange by Flange

(Flanged)

3M-201

Weld by Weld

(Weldnek)

NA

300 3M-013 3M-103 NA 3M-023 3M-203 NA

600 3M-015 3M-105 3M-185 3M-025 3M-205 3M-285

H~h Pressure 3 Section Meter Tubes 900 3M-016 3M-106 3M-186 3M-026 3M-206 3M-286

1500 3M-017 3M-107 3M-187 3M-027 3M-207 3M-287

2500 3M-018 3M-108 3M-188 3M-028 3M-208 3M-288

2middot8 with Simplex 2middot12 with Orifice Flanges Flange byPressure

WeldRating Weld by Weld (Flangnek) (Weldnek)

150 3M-071 NA 3M-073300 NA

600 3M-075 3M-705 High Pressure

3M-7063M-076900 3M-7071500 3M-077 3M-7083M-0782500 -

Two Section Meter Tubes When Usmg Weldnek Flttmgs

Senior and Simplex fittings are also available in 10000 psi rating in some sizes All units are also available with Ring Type Joint (RTJ) flanges on request Sizes larger than 12 available on request

PackingShipping Daniel bolts together all meter A SPECIAL NOTE The use of factory original Daniel tubes when size permits before shipment This saves parts will assure your Senior Junior and Simplex Orifice the user time and field labor costs Fittings are protectshy fittings will stay within original specifications and operate ed by heavy lumber and the tube flanges by special-cut properly protectors

PaintingCoating The Daniel standard paint is a basic enamel type Special coatings such as multi-coat

offshore systems are available on request

3~Section Meter Tube with Tube Bundle

~-----~ U ----~---------~=~~middotmiddotmiddotmiddot~middot t)middotmiddot-middot ~- - -0bull )00)00 1

I~IC--middotmiddotmiddot-middot -----shyshy-bullmiddotV ------- ~

~ - ~-

~

ii~pound bullbullbull ~

Standard lenAths Size un Upstream 0 Downstream V (vane location)

3 7-5 4-0 130 4 9~~9 4-0 130

6 14-8 5-0 t30

102410 60middot middot 130 1~ +1 2tYS Tq 130 JiIf

Note Straightening vanes are not available in 2line size (See Dald Profller DAN-1852middot 2M)

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Daniel meter tubes can be supshyplied in many combinations and configurations Any of the orifice fittings plate holders or orifice flanges can be included in a meter tube Each 3 section standard meter tube is equipped with a flange mounted tube bundle straightener In accordance with April 2000 API 143 and a 1h thick spacer to facilitate tube removal for inspection Downstreams are longer than minimum required to allow for field Installation of additional branch connections If required

To specify a 3 section meter tube use the designation 3M followed by the type orifice holding deVice Ex 4 600 3 section meter tube with flanged ends using a Senior fitting flangneck style is specified as 4-3M-015 The same unit with a weldneck style Simplex is specified as 4middot3M-705 When ordering specify pipe schedule and end configuration Larger size and custom meter tube designs are available on request

The Daniel Profilertrade three section meter tube is availshy lows and contains 2 branch connections Other or addi able with any style Senior or Junior orifice fitting Simplex tiona I connections can be supplied in this section on plate holder or orifice flanges The assembly contains an request These meter tubes are for use in any piping conshyinlet spool of tile minimum length determined during testshy figuration with beta ratios to 67 Downstream sections ing to the API 143 standard The flange union between are extra long to allow for the addition of extra branch the first and second sections contains the ProfilerN and connections in the field if desired The standard meter a Y2 thick spacer plate to facilitate tube removal for tube has beveled outer ends Flanges or other end conshyinspection The outer end of section 2 contains the orishy nections are available on request fice flange or fitting The third or downstream section fol

Meter Tubes Catalog Numbers - 2 WI emor In9 bull Wit un or Itt ng2 1 th S Fitt 10 amp 12 h J i F i

Pressure Rating

Flange by Weld

(F1angnek)

Flange by Flange

(Flanged)

Weld by Weld

(Weldnek)

Flange by Weld

(Flangnek)

Flange by Flange

(Flanged)

Weld by Weld

(WeJdnek) 150 M011 M-101 NA M-021 M-201 NA 300 M-Q13 M-103 NA M023 M-203

NA 600 M-015 M-105 M-t85 M-025 M-205 M-285

2middot8 with Simplex 2middot12 with Orifice Flanges

Pressure Rating

Flange by Weld

weld by Weld

(Weldnek)CFlananekl 150 M-071 NA 300 M-073 NJA 6QfJ M-()75 M-705

Raised Face Weld Neck

NA - -

lM-30RW M-60RW

Two Section Meter Tube When USing Weldnek Fittings

Consult Factory for High Pressure Applications

PROFILERTM Flow Conditioning Plate

The Profiler has been tested and Shown to be in full compliance with the requirementS of API 143 April 2000 The Profiler both removes swirl

the tube bundle Available In flange mounted model only Also available In RTJ style on request

and creates a fully developed flow profile at the orifice Use of this unit allows shortened upstream straight pipe lengths of 17 diameters Beta ratio limit is 67 as with

-~---

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 2: Medidor de Flujo

n ISO 90012000AZ I EC=A CERTIFIC4O()

CORPO lt l lU-- COlTIW ( TOIJ SEMBRAHDO ISO 9000

20 de Octubre del 2004

Partida cantidad Descripcion 02 1 Transmisor TotaUzador Integrador de f1ujo Marca Dynamic Fluid Modelo ECHART

para servicio de gas natural amargo y condensados con las siguientes caracteristicas

bull Disano compacta debido a que cuenta con modulo sensor digital multivariable integrado al computador para la medicion de temperatura presion asiatica y presion diferencial

bull Caja de Aluminio fo~ado libre de Cobre para areas peligrosas y ambiente corrosiv~ con recubrimiento de resina ep6xica y a prueba de explosion Clase 1 Div 1 Grupos B C Y D y clasificacion NEMA 7 Y NEMA 4X

bull Condiciones ambientales Temperatura de operacion de -40deg C a 85deg C bull Humedad relativa Hasta 100 sin condensacion bull Cuenta con ventana para visualizar la pantalla 0 display LCD sin abrir el instrumento bull Conexion eecbica Dos para tuberia conduit de tlPT bull Conexion a proceso De 1-18 NPT bull Material de la brida de proceso Acero Inoxidable 316 bull Alimentacion 6 a 28 VDC desde fuente extema 0 panel solar bull Consumo de energia 25 rnA a 12 VDC bull Opcion de alimentacion Por medio de panel solar de 5 Watts 6Vo~s

bull Pantalla Display tipo LCD grafica de 128X64 Pixeles8lineas de 16 caracteres bull Informaci6n desplegabe en pantalla La informacion se puede dasplegar en forma

grafica y alfanumerica Capaz de mostrar dos tendencias por cada pantalla y daspliega un total de 6 tendencias Los valores de las variables se despliegan uno tras otro en intervalos de nempo configurable en multiplos de 1 2 3 Y 4 segundos sin resbiccion en tiempo

bull Limites de temperatura (para la unidad con display) De operacion es de -40deg a 85degC y de almacenamiento es de -46deg C a 87deg C

bull Vibracion Desde 5 hasta 2000 Hz en cualquiereje segun procedimiento de prueba IEC 770 seccion 6214 Aprobado por SAMA PMC311

bull Cuenta con tecnologia basada en microprocesadores de 32 bits a 167 MHz de velocidad con memoria de programacion (EPROM) de 4MB memoria para datos de 2 MB para almacenamiento de informacion e historicos de hasta 64 dias

bull Reloj en tiampo real AnoMiesDialHoraMinuto bull Cuenta con bateria de respaldo de fitio para el reloj y para la memoria bull Una Entrada de frecuencia bull Entrada Digital 1entrada (+) digital de 7 a 24 VDC negativo a comun bull Una salida anal6gica de 4-20 rnA Resolucion 12 bits bull Una salida digital Tipo ONOFF 0 de pulsos (hasta 125 pulsosseg) bull Entradas de RTD Una entrada de RTD en el mOdulo multivariable y una entrada en

tablillas del computador Resolucion 24 bits

CO(QQracion Constructora Azteca SA de 0 I Protectotank Diaz Mir6n 805 Col Centro cP 96400 Coatzacoalcos Ver Tel (01921) 21212 2021215042126517 Fax (01921) 21 22451

e-mail cramosprotectotankcommx sitio web wwwprotectotankcommx

lt0 ~I ISO 90012000AZIECA CERTIFle ADQ

CORPORACIU~ c unwcrOR SEMBRANDO ISO 9000

scombustible 20 de Octubre del 2004

Partida cantidad Descripcion 02 1 bull Aislamiento Optico Cada entrada y cada salida esta foto-opticamente aislada con un

maximo de rechazo de modo comun en entradas y salidas de plusmn 250 VDC a tierra del chasis

bull Sistema de autodiagnostico Monitorea y alarma las siguientes condiciones

Estado del sensor multivariable en Presion estatica Presion diferencial y Temperatura

Estado de la entrada digital

Estado de las salidas de contacto

Estado de la entrada de frecuencia

Temperatura intema

Valores de voltaje intemo y de Ia bateria

bull Comunicaciones Un puerto serial RS232 0 RS485 velocidad de transmision de 1200 a 9600 BPS protocolo MODBUS RTUASCII Y un puerto serial RS232 velocidad de transmision de 1200 a 9600 BPS protocolo MODBUS RTUASCII

bull Elementos primarios de medicion compatibles Diferencial Placa de orificio V Cone Wedge Annubar Venturi De pulsos Turbinas PO Vortex Ultrasonicos Masicos

bull Unidades de Ingenierla US y Metrico bull Ecuaciones para caiculo de flujo AGA 3 API 143 AGA 7 AGA 9 Y AGA 8 Metodos 12

y detallado API 56 API5 API 2540 API11-2-1 API11-2-2 Todos los calculosreporteshist6ricosalgoritrnos etc En acuerdo a los lineamientos del API Capitulo 211

Sensor Multivariable MOdulo multivariable 3 en 1 modelo 205 de Rosemount Cuenta con Ia tecnologia de oolda de capacitancia para sensar la presion diferencial sensor piezoresistivo con silicon para sensar la presion estatica y una entrada para RTD que se encarga de sensar la temperatura Sensor de Presion Diferencial Rango desde 0-250 pulgadas de H20 Con una exactitud del plusmn 0075 del span para spans desde 11 a 101 del URL que incluye los efectos de linealidad histeresis y repetibilidad

Sensor de presion absolutal manometrica Rango desde 0-3626 PSI Con una exactitud del plusmn 0075 del span para spans desde 11 a 101 del URL que incluye los efectos de linealidad histeresis y repetibilidad

Sensor temperatura de proceso Es compatible con cualquier tipo de RTD de Platino100 Ohms de 23 0 4 hilos Con un rango de -40a C a 6490 C con una exactitud de plusmn 056deg C que incluye los efectos de linealidad histeresis y repetibilidad

Corporacion Constructora Azteca SA de 01 I Protectotank Draz Miron 80S Col Centro CP 96400 Coatzacoalcos Ver Tel (01921) 212122021215042126517 Fax (01921) 21 2 24 51

e-mail cramosprotectotankcommx sitio web wwwprotectotankcommx

m ISO 9001 2000 CERTIFIC AOQ

20 de Oetubre del 2004

Partida Cantidad Oeseripelon 02 1 bull Materiales de eonstrueeion del modulo multivariable

Conexiones a proeeso ~NPT con distaneia entre centros de 218 Partes humedas Diafragma de Hasteloy C (para manejo de gas amargo NACE

MR-01-75) Bridas Acero Inoxidable 316 Anillos de las partes humedas De teflon con alma de vidrio Partes no humedas EI fluido de lienado es Aeeite de silicon anilos de Buna N

Incluye

Un kit de montaje de Acero Inoxidable 316 para pedestal de 2 Un manifold de 5vias de Acero Inoxidable 316 de de diametro para una presion

maxima de 10 000 psi (700 Bar) Software de programaeion gratuito (Ambiente Windows) Embalaje apropiado para embarque a destino marino Documentos ineluidos Certificado de materiales Garantia de operaeion Hojas de

datos rellenas Manuales de mantenimiento operacion y eonfiguracion (en ingles) Lista de partes de repuesto Certifieado de pruebas de planta Certifieado de ealidad Protocolo de pruebas y ealibraeion Certifieado de Calibraeion de la planta

Precio Unitario $ 530000 usn +IVA

Terminos comerciales 1 Validez de la oferta 90 dfas 2 Tiempo de entrega 120 dfas 3 Forma de pago 30 dfas presentacion factura 4 Garantfa de caUdad 12 meses de operacion 018 despues del embarque 5 Precios fijos en dolares arnericanos + NA 6 Embalaje adecuado tipo marino 7 LAB su almacen PEP Cd Del Carmen Campeche

1 Atentam nte

Ing Carlos Manuel Ramos Yeh Corporaci6n Constructora Azteca SA de cv

cramosprotectotankcommx Auxiliar de gerencia

Corooracion Constructora Azteca SA de CV I Protectotlnk Diaz Miron 805 Col Centro c P 96400 Coatzacoalcos Ver Tel (01921) 212122021215042126517 Fax (01921) 21 2 2451

e-mail cramosprotectotankcommx sitio web wwwprotectotankcommx

-- - -

- - -

- - -

V -Conereg Preliminary Sizing

Description ~-cone 8 CSS316 Cone S80 ANSI WN CL600 RF

1000 Fa - aPE D67e-06 d 67e-06

Pv

HL I 210 inWC

~ Entered value Table based on one flow condition (P T Z k ) V25 Version 41

Record Start Date 10-18-2004

Print Date 10-20-2004 ~ McOOMEIER L _ _ _ _ _

By Corporacion Constructora Azteca SA de CV

Fluid

Serial Fluid State

End User Job Ref

IndustryModel

Tag I Gas Combustible r-

f--shy

VW08FF 16N-BAZ

NATURAL GAS 174mw

GAS

CPTG ATASTA

PEP

Note r-085

I kgcm2Gr30 degc

2444 Ibft3

1135e-02 cP -

p

G 06008

Z 09172

Y 09918 c-- - - shy

k I 1302

8573 Cp

Mw 17400

14 696 psi -

OF60000

I 09979 I I 14696 psiPbaro

Pc I 66720 psi

of-11657Tc

----------------------------------------------------------------~

q max Flowrate 50000000 SCFD

6977e+06

34 22 fps

28208 inWC

01110 inWC

7636 in

6820 in

04498

50

McCrometer Cal

Third Party Cal Re max Reynolds

Dye Pen Exam V max Velocity

Hydro Test ilP max Dp

ilP min Dp X-Ray Exam

D Meter 10 Mag Part

d Cone OD PMI

p Beta Ratio CMTR Copies

Turn Down Application Eng

I--- shy

CMRY

Velocity Gas Exp ilP Flowrate

Re fps Y inWC SCFD

1 6977e+06 3422 09918 2821 50000e+07

2 6217e+06 3049 09935 2232 44556e+07

3 5458e+06 2676 09950 1715 39111e+07

4 4698e+06 2304 09963 1267 33667e+07

5 3938e+06 1931 09974 8885 28222e+07

6 3178e+06 1559 09983 5777 22778e+07

7 241ge+06 1186 09990 3341 17333e+07

8 165ge+06 8136 09995 1570 1188ge+07

9 8993e+05 4410 09999 4610 64444e+06

10 1395e+05 06843 1000 01110 10000e+06

File Gas Combustible ATASTAv25

yeoNE reg CONFIGURATION SHEET

PRECISION TUBE SERIESMODELVW (H)

ANSI 8165 Weld Neck Raised Face Flanges - Class 600 or 900

DESCRIPIION AND GENERAL PERFORMANCE SPECIFICATIONS The V -Conereg flowmeter is a patented differential pressure type flow measurement device A cone is positioned in the center of the pipe to increase the velocity of the flowing fluid and create a differential pressure This pressure difference can be measured and used to accurately interpret flowrate Two taps are provided on every V -Cone to allow sensing of the high and low pressures A typical V-Cone application can follow these general performance specifications bull Accuracy up to plusmn05 of rate Model VW Bulletins

ANSI 8165 Weld Neck RF Flanges 24509-35 Class 150 or 300

bull Repeatability plusmnO J bull Turndown 10 1 24509-36 Class 600 or 900 bull Standard Betas 045 through 085 24509-37 Class 125 or 250 bull Headloss Percentage of differential pressure produced varies with beta ratio bull Installation Typically 0-3 diameters upstream and 0-1 diameters downstream Each V -Cone is sized for the intended a Ii cation S ecific erformance ratin s must be obtained throu

MODEL VW(H) DIMENSIONS

H L 2 1 8 (Note 2) B1- ~WE-D DC

~ I -rr --- - T - III

Lk-l - -- -- c-ttt- -- - -- -- - -- -

- - --- --- ---

I

--------------A------------~-t I A lor to 1 1lor to 24

DIMENSION TABLE

I

Size ANSI B165 Class 600 ANSI B165 Class 900 Stainless Carbon

0 E (Note 2) A (Note 1) B A(Note 2) B C (Note 2) C (Note 2)

inch inch mm inch mm inch mm inch mm inch mm inch mm inch mm NPT

y 1225 3112 563 1430 1288 3272 594 1509 0622 158 - - 084 213 Y Y 1263 3208 582 1478 1363 346 2 632 1605 0824 209 - - 105 267 Y 1 1300 3302 601 1527 1388 3526 644 1636 1049 26_64 gtshy - - 1315 334 Y 1Y 1550 3937 576 1463 1650 419 1 626 1590 1645 4178 - - 19 483 Y 2 1763 4478 631 1603 1988 5050 744 1890 2104 5344 - - 2375 603 )I

2)1 1800 4572 650 1651 2000 5080 750 1905 2504 6360 - - 2875 730 Y

3 2025 5144 663 1684 2175 5525 738 1875 3104 7884 - - 35 889 )I

4 2375 6033 788 2002 24 75 6287 838 2129 4090 1038 - - 45 114 Y

6 3100 7874 875 2223 3275 8319 963 2446 6065 1541 6065 1541 6625 168 Y

8 3600 9144 1001 254 3 3825 971 _6 1113 2827 7981 2027 7981 2027 8625 219 )I

10 3950 1003 1076 2733 4200 1067 1201 3051 1002 2545 1002 254 5 1075 273 Y

12 4175 1060 1113 2827 452 5 1149 1288 327 2 1200 3048 1194 3033 1275 323 Y

14 4225 1073 1213 3081 4600 1168 1400 3556 1325 336 6 1313 3335 14 355 Y

16 4325 1099 1263 3208 4625 1175 1413 3589 1525 3874 1500 3810 16 406 Y

18 4575 1162 1288 3272 4925 1251 1463 371 6 1725 438 2 1725 4382 18 457 Y

20 5025 )11276 11 1313 3335 5475 1391 1538 3907 1925 4890 1925 4890 20 508 Y

24 6325 1607 1763 4478 7025 1784 2113 536 7 2325 5906 2325 5906 24 609 Y 1 Overall length (A) tolerance vanes With line size jYto 1 plusmn18 (plusmn4mm) 1 jYto 10 plusmn316 (plusmn6mm) 12 to 24 plusmn14 (

2 Typical values shown

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-68111 Fax (909) 652-3078$ MQ[)MEIER Web Site httpWlNwmccrometercom e-mail infomccrometercom

Lit24509-36 Rev 146-00 copy2000 by McCrometcr Inc Printed in USA

I bull

CONFIGURAIiON SHEET MODEL NUMBER CONFIGURATION VW(H)

Pipe Size Materialsj Schedule FittingsEnd Connections

VW Q A 10OA S304V2 JLj CL 600 RF WN LtJ NPT

OB L S304L B 20 17 CL 900 RF WN S Socket 01 1 A S316L C Bored

Scvcmllypcs of ICS Tube amp Flanges 0 StdOC 1V2 ~ fittings aV01ilablc

2 40 00

S304 Cone Support amp Couplings E02 Epoxy Coated Blue (excluding cone) F 80

03 2V2 3 r-u CS Tube amp Flanges J 100

04 4 S304 Cone Support amp Couplings 120K jOther materials can include6 Coating Painting Per Customer Req 14006 L

-shy HASTELLOY C-276 S321H8 G 160 DUPLEX 2205 INCONEL 625

08 10 XXS

CHROMEMOLY P22PII 10 H

10S MONEL K400K500

12 M12 14 P XS

CARBON STEELS 14

16 -- shy

A350 A333 AP15L A 106B 16

18 20 18

20 24~

Example VW10AE16N V-Cone 10 inch line size S316L schedule 40 pipe ANSI CL 600 RF WN flanges V2NPT fittings

Type

STANDARD PIPE SCHEDUIpoundS Stainless Steel Carbon Steel

Size Std Size Std to 4 C

6 to 10 E 12 and up 0

6 to 16 18 and up

E 0

Pipe up to 8 utilizes seamless pipe Above 8 is welded pipe

ABBREVIATIONS ASME American Society of Mechanical Engineers NPT National pipe taper SS Stainless steel RF Raised Face CS Carbon steel WN Weld Neck

Technical questions can be answered through a local representative or through our application engineers

REPRESENTED BY

MANUFACTURING STANDARDS McCrometers welders and welding procedures are qualified in accordance with ASME Section IX All meters are visually inspected for weld defects Specific customer requirements can be complied with upon request

The welding can be in accordance with

bull ASME Section VIII

bull ASME B311

bull ASMEB313

Non-destmctive testing can include

bull Hydrostatic Pressure Testing

bull Penetrant Examination

bull Radiographic Examination

bull Positive Material Inspection

bull Magnetic Particle Examination

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-6811 Fax (909) 652-3078 Web Site httpwwwmccromelercom e-mail infomccrometercom

Lit24509-36 Rev 146-00 copy 2000 by McCrometer IncPrinted in USA

~----------------------~---------------------------------------------------------------------------

V -Cone Installation Guide Upstream and Downstream Minimum Straight Pipe Run Requirements

For Liquid Metering and Gases at a Reynolds Number (Re) Value Less Than or Equal To 200000

For fl greater than or equal to 065 add ID

Obstruction DownSize Range Up Stream Stream

I Elbow OD

2 Elbows

OD

OD OD

Tees OD OD Not Preferred ValveAll Sizes Butterfly Valve (control valve) DownstreamPosition

3D 3D

Butterfly Valve (shutoff valve) 3D OD

Full port Ballvalve (shutoff) OD OD

Heat Exchanger (Depends on Type) OD OD

Expander (067D to D) over a length ID ID of 2SD

Reducer (3D to D) over a length of ID ID 3SD

Note The meter and adjoining pipe should have equal IDs

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-6811 Fax (909) 652-3078 ~ MCOOMEIER Web Site http wwwmccrometercom e-mail infomccrometercom

Lit24S09-21 Rev 10102-04 copy2004 by McCrometer InclPrinted in USA

Product Data Sheet DAN-GFM-DS -21-rev0404 ( )

April2004 SeniorSonic with Mark TM Electronics

- SeniorSonic The Daniel SeniorSonic Gas Flow Meter with Mark IWM Electronics saves you time and money Lost and unaccounted for gas is reduced by exceptional low and high flow accuracy and linearity throughout the calibrated flow range Time is saved by a best-in-class audit trail Mark III Electronics can pinpoint alarms events and configuration changes in a matter of seconds Best of all operating the Daniel SeniorSonic gas flow meter is easy with the Windowsreg based Daniel Customer User Interface (CUI) software

Features middot Excellent long-term performance

Velocity Range Most sizes are rated to performa at 100 fps middot Full electronic audit trail (exceeds API 211) Over-range of up to 125 fps and in some cases beyond 125 middot Exceptional low and high flow performance

middot Bi-directional multi-point calibration coefficients fps in emergencymiddot situations and without transducer failure

middot Rangeability exceeds 50 1 with calibration Availability is limited by line size and ANSI rating Visit middot ANSI 30060090015002500 versions wwwdanielcomseniorsonic for additional information middot Extractable transducers (For all sizes) middot Minimum upstream piping requirements Meter specifications

Gas temperature -4 to +212deg F (-20 to +100deg C) Easy to learn and use CUI software features Operating pressure range 150 - 3750 psig middot Comprehensive monitor screen (1030 - 25855 kPa) Consult factory for lower and middot Field start-up wizard higher pressure applications middot Calibration wizards (analog and frequency) Flanges RF for 3001500 RTJ for 6002500 middot Flow calibration configuration wizard middot Audit 1 alarm 1history retrieval Power DC version - 1224 (11-36) VDC 6 watts maximum middot Digital waveform viewing middot Maintenance log summary in ExcelI Environmental middot Built-in AGA 10 SOS calculator Operating temperature -40 to +149deg F (-40 to +65deg C) middot Automatic file naming Operating relative humidity up to 95 non-condensing middot Trending of maintenance logs Storage temperature -40 to +185 0 F (-40 to +85 0 C) middot Configuration comparison with exception summary middot Remote dial-up support and Ethernet support Typical Applications middot Unlimited meter directory support middot Custody transfer

middot Power plants Specifications middot Large industrial users

Electronic unit middot City gates Communication protocol Modbus RTUASCII amp TCPIIP middot Production Two serial RS-232485 ports and Ethernet middot Underground storage sites Communication speed Up to 115 KBPS middot Offshore Frequency outputs Four Frequency range 0-10005000 Hz Safety classifications Digital output Selectable (up to four for data valid or flow UL listed for use in Class I Division 1 Group D hazardous

direction) locations in both the US and Canada (UL E152246) Calculation update time Configurable for 14 and 1 second CE marked to ATEX directive (949EC ) (pending)

Certified to Eex d ia liB T4 to standards EN 50014 EN 50018 Accuracy and EN 50020 (pending) Flow calibrated accuracy plusmn 01 (Relative to lab) Absolute accuracy Including lab uncertainty about 03 Repeatability plusmn 02 of reading for Ot to Omax

-- - tI II~ EMERSON ~-----

wwwdanielcom

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Recommended Ma~jum Flow Velocity Meter Size J Meter Size Metric Max Inches Max ftI~ m tris

4 100 100 30 6 100 150 30 8 100 200 30

10 80 250 24 12 80 300 24 16 85 400 26 20 85 500 26 24 85 600 26 30 70 750 21 36 70 900 21

Dimensions These measurements are meant only as an aid in the design of metering systems Consult Daniel engineering drawings prior to construction

Typical 600 ANSI Meter with 45 Degree-Angled Transducers Overall End- Flange Approximate Overall End- Flange Approximate

Meter Size To-End Diameter Weight To-End Diameter Weight (Inches) (Inches) (Inches) (Pounds) (Millimeters) (Millimeters) (Kilograms)

4 2900 1075 370 737 273 168 6 2950 1400 460 749 356 209

8 3150 1650 650 800 419 295 10 3400 2000 885 864 508 402 12 3544 2200 1075 900 559 489 16 4400 2700 1955 1118 686 889 18 4531 2925 2800 11sect1 743 1273 20 5062 3200 30Z5 12amp6 84~ 1398

0 4 5862 3700 404~ 1489 940 1839 30 6700 4450 4925 1702 1130 2239 36 7350 5175 6425 1867 1314 2920

()l p l ( C flO

bull I iY0

e

Page 2

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 60 F and gas composition These values are intended to be a guide in Contact Daniel engineering for a specific application

_ Flow Rates (JIISCFHl Basea Upon 100 ftls PSIG 4 6 8 10 12 16 20 24 30 36 100 247 561 971 1532 2174 3432 5398 7807 12607 18154 200 468 1065 1845 2908 4127 6515 10248 14822 23935 34467 300 696 1584 2743 4325 6137 9690 15240 22043 35596 51258 400 931 2118 3668 5782 8206 12955 20377 29472 47593 68534 500 2667 4619 7282 10334 16315 25661 37114 59934 86305 600 1421 3232 5597 8823 12522 19770 31095 44973 72626 104582 700 1676 3813 6602 10409 14772 23322 36682 53055 85677 123374 800 1938 4409 7635 12036 17082 26968 42417 61349 99070 142661 900 2207 5021 8694 13706 19452 30710 48302 69861 112816 162455 1000 2482 5646 9777 15414 21875 34536 54320 78565 126872 182696 1100 2763 6286 10885 17161 24355 38451 60478 87471 141254 203405 1200 3050 6939 12015 18943 26883 42443 66756 96551 155917 224521 1300 3341 7602 13164 20753 29453 46500 73137 105781 170822 245983 1400 3637 8274 14327 22587 32055 50608 79599 115127 185915 267718 1500 3935 8953 15504 24442 34688 54765 86137 124583 201184 289706 1600 4235 9635 16685 26305 37331 58938 92700 134076 216515 311781 1700 4536 10321 17871 28175 39986 63128 99291 143608 231908 333948 1800 4836 11002 19052 30036 42627 67298 105850 153094 247227 356006 1900 5134 11681 20226 31888 45255 71448 112376 162534 262471 377958 2000 5429 12350 21386 33716 47849 75543 118818 171851 277516 399623

Flow Rates (MIfIISCFfJ) Based Upon 100 ffls PSIG 4 6 8 10 12 16 20 24 30 36 100 59 135 233 368 522 824 1295 1874 3026 4357 200 113 256 443 698 990 1564 2459 3557 5744 8272 300 168 380 658 1038 1473 2326 3658 5290 8543 1230 400 224 508 880 1388 1969 3109 4890 7073 1142 1645 600 282 640 110~ 1748 2480 3916 6159 8907 1438 2071 600 342 776 1343 2118 3005 4745 7463 1079 1743 2510 700 403 915 1685 2498 3545 5597 8804 1273 2066 2961 800 466 1058 1832 2889 4100 6472 1018 1472 2378 3424 900 531 1205 2087 3289 4668 7370 1159 1677 2708 3899

1000 597 1355 2346 3699 5250 8289 1304 1886 3045 4385 1100 665 1509 2612 4119 5845 9228 1451 2099 3390 4882 1200 734 1665 2884 4546 6452 1019 1602 2317 3742 5389 1300 804 1824 3159 4981 7069 1116 1755 2539 4100 5904 1400 875 1986 3438 5421 7693 1215 1910 2763 4462 6425 1500 947 2149 3721 5866 8325 1314 2067 2990 4828 6953 1600 1019 2313 4004 6313 8960 1415 2225 3218 5196 7483 1700 1091 2477 4289 6762 9597 1515 2383 3447 5566middot 8015 1800 1164 2641 4572 7209 1023 1615 2540 3674 5933 8544 1900 1235 2803 4854 7653 1086 1715 2697 3901 6299 9071 2000 1306 2964 5133 8092 1148 1813 2852 4124 6660 9591

Calculating meter capacity To calculate a volume rate for a given velocity multiply the capacity in this table by the desired at the pressure and divide the answer by 100 Example Determine the hourly flow rate al 70 fps for an 8 inch meter operating at 800 psig Volume =7635 MSCFH Velocity 70 Answer = 763570100 = 5344 MSCFH

Pa~e 3

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 20 F and gas composition These values are intended to be a guide In Contact Daniel nee ring for a application

Flow RateS (IASOFH) Based UppJ1 30 mls Schedule 40) kPag 4 6 8 10 12 16 20 24 30 36 1000 967 2201 3811 6007 8527 1346 2117 3062 4945 7121 1500 1422 3234 5600 8827 1253 1978 3111 4500 7267 1046 2000 1885 4289 7428 1171 1662 2624 4127 5969 9639 1388 2500 2359 5367 9294 1465 2079 3283 5164 7469 1206 1737 3000 2843 6468 1120 1765 2506 3956 6223 9000 1453 2093 3500 3337 7592 1315 2072 2941 4644 7304 1056 1706 2457 4000 3841 8739 1513 2385 3386 5346 8408 1216 1964 2828 4500 4356 9910 171S 2705 3840 6062 9535 1379 2227 3207 5000 4881 1111 1923 3031 4303 6793 1068 1546 2495 3593 5500 5417 1232 2134 3364 4774 7538 1186 1715 2769 3987 6000 5962 1 3702 5255 8297 1305 1887 3048 4389 6500 6517 1483 2568 4047 5745 9070 1427 2063 3332 4798 7000 7082 1611 2790 4398 6243 9856 1550 2242 3621 5214 7500 7656 1742 3016 4754 6748 1065 1676 2424 3914 5636 8000 8238 1874 3246 5116 7262 1146 1803 2608 4212 6065 8500 8828 2009 3478 5482 7782 1229 1932 2795 4513 6499 9000 9425 2144 3713 5853 8308 1312 2063 2984 4818 6939 9500 10028 2281 3951 6227 8839 1396 2195 3175 5127 7382

10000 10636 2420 4190 6604 9375 1480 2328 3367 5437 7830

Flow Rates (IANSOND) Based Upon 30 mls (Scnedule 40) PSIG 4 6 8 10 12 16 20 24 30 36 1000 0232 0528 0915 1442 2046 3231 5082 7350 11869 17091 1500 0341 0776 1344 2119 3007 4748 7468 10801 17441 25116 2000 0453 1029 1783 2810 3989 6297 9904 14325 23133 33311 2500 0566 1288 2231 3516 4991 7879 12393 17924 28946 41682 3000 0682 1552 2688 4237 6014 9495 14935 21600 34882 50230 3500 0801 1821 3155 4973 7059 11145 17530 25354 40943 58958 4000 0922 2097 3632 5725 8126 12830 20179 29186 47131 67869 4500 1045 2378 4119 6492 9215 14549 22883 33097 53447 76963 5000 1171 2664 4615 7275 10326 16302 25641 37086 59889 86240 5500 1300 2957 5121 8072 11459 18091 28454 41154 66458 95699 6000 1431 3254 5637 8885 19912 31319 45298 73150 105336 6500 1564 3557 6162 9713 13787 21767 34236 49517 79964 115148 7000 1700 3866 6696 10555 14982 23653 37203 53808 86893 125126 7500 1837 4179 7239 11410 16196 25570 40218 58168 93934 135265 8000 1977 4497 7789 12278 17428 27515 43277 62592 101078 145553 8500 2119 4819 8347 13157 18676 29485 46376 67075 108318 155978 9000 2262 51 8912 14047 19939 31479 71611 115642 166524 9500 2407 5474 9482 14945 21214 33492 52679 76191 123038 177175

10000 2553 5805 10056 15851 22500 35522 55871 80808 130494 187911

Calculating meter capacity To calculate a volume rate for a given velocity the capacity this table by the desired velocity at the operating pressure and divide the answer 100 Determine the hourly flow rate at 30 mps for an 8 inch meter at 4500 Volume 1716 Velocity 10 Answer 17161030 5719 MSCMH

Product Oata Sheet DAN-GFM-DS-21-rev0404 April 2004

The drawings below represent recommended piping lengths for various flow conditioners when installed with the Daniel SeniorSonic flowmeter If shorter lengths are used there may be an increase in flow measurement uncertainty

Piping Recommendation For SeniorSonic With No Flow Conditioner

1~~--------------------200 -----------------------~

Q----I__------shy~

J ~~f --M-I-middotn-im-~-~-p-iP-i-n-g-R-e-c-o-m-m-e-n-a-a-tl-o-n-F-o-r-S-en-I-o-r-S-o-n-ic-W-it-h-D-a-n-ie-l-p-r-O-fi-le-r-o-r-C-p-~-5-0-E~-F--o-w-c-o-n-d-itl-io-n-e-r--

1 00 middot -2 o~o ~1gt

[ _____ ---Al11~ ----- =ul [II I

I 0 0 a It Minimum Piping Recommendation for Bimiddotdirectional SeniorSonic

with Daniel Profiler or CPA 50E Flow Conditioner

~------- 100 ------t ~------- 100 ----~ - 50---shy

3middot 50

-- 50 ---shy

3middot 50

~ -

A WARNING Do not operate this instrument in excess of the specifications listed Failure to heed this warning could result in serious injury andor damage to the equipment

Page 5

---- - --- _ --- ----------------- -------------------------shy

--iI

-------~~--------1

----~----------------I _____________________I

----~------~----__i _____bullmiddot________ ----__i

____________shy____~__i

____________________---i __________________

_________shy__________~~

~ I ~

I

~

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

8

10

12

16

20

24

30

36 r

ANSI Class 300 600--~------------------------i

900__________----__------__------i 1500

-------------------------------~ Flange Raised Face (RF) _________________-_------j

Ring Type Joint (RTJ)___---------__bull-_____Imiddot

Materials Standard ~----~~--~----~--------~~ Stainless Steel

DJplex --~--------------------------~----~ _________________________--____~__

Device Type

Electronics

Transducers

Meter Size (Inches)

Daniel Ultrasonic Model Number Selections ES-21055 RevW

SeniorSonic (4-Path) ---------------1 JuniorSonic (1~Path) ------------1 JuniorSonic (2-Path) ______________

Mark II UL 24VDC 4-20rlA 3NPT

Mark UL 24VDC 1middot5VDC 3NPT ---------------------1 Mark CENaEC 24V DC 4-20mA M20 --------------_--__1

Mark IICB-JELEC24VDC1-SVDCM20

Mark II ClNELEc 24VDC 4-20mA M20 Rerrote

Mark II CENELEC 24VDC 1-5VDCM20 Rerrote

MarkU UL 24VOC4-20mA 3NPT Rerrote_

Mark II U~ 24VDC l-SVPG 3NPT Rerrote

Mark IIIUL 34 NPT

Mark III UL 34NPT Rerrote

TmiddotSlo T-12

4

middot 6

Page 6

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Systems Daniel Measurement and Control is the industry leader in designing constructing and commissioning of complex oil and gas metering systems to exacting standards

This global organization offers decades of petroleum fiscal flow measurement application experience Customers rely confidently on Daniels Systems Group international fabrication facilities customized engineering and its successes in field-testing and support From the simplest single-stream skid to complex on-site installations Daniel Systems delivers both natural gas and liquid petroleum tumkey applications Daniel Systems designs constructs and commissions the metering project blending up-toshythe-minute technology with decades of understanding what customers need and expect

Components of a Daniel Systems installation typically include meters valves provers flow-control instruments instrumentation and read-out equipment and process management components

Computer software and hardware are integrated with the measurement system Standard calculation methods include AGA3 (now API-MPMS-143) ISO 5167 AGA578 AGA9 and the API Manual for Petroleum Measurement Standards

Daniel DMSS-2000 Supervisory Control Systems utilize a sophisticated Graphical User Interface database server and a dedicated PLC for the metering skidMOV interface Redundancy is often used for custody transfer systems andor when system integrity is essential

A dedicated Project Manager and Project Team are assigned to each measurement system project This team is responsible for overall system design and project construction from start to finish A separate internal QAQC group reviews all design detailS inside and outside fabrication assembly and system testing

Whether it is a pipeline offshore production facility or a loading facility for ocean-going tankers the Daniel Systems group is a proven single-source solution for customers throughout the world

Page 7

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Daniel Measurement Services Daniel Measurement Services takes pride in being there after needs arise with the right solution for customers with gas and liquid fiscal flow measurement applications

Around the clock and around the world Daniel Measurement Services has experienced highly qualified people prepared to help customers who need assistance with the following

middot Start-up and commissioning middot Preventive maintenance middot Product repair I upgrades middot Project management and integration middot Meter Tube inspection and recertification middot Remote diagnostics middot Warranty Plus middot Technical training

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880

Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337

Stirling Scotland - UK Middle East amp Africa T +4401786433400 F +44 01786433401

Singapore - Asia Pacific T +65-6777-8211 F +65-6770-8001

USA Toll Free 1-888-FLOW-001 wwwdanielcom

Daniel is a whOlly owned subsidiary of Emerson Electric Co and a division of Emerson Process Management The Daniel logo is a registered trademark of Daniel Industnes tnc The Emerson logo is a trademark and service mark of Emerson Electric Co Brand mark listing are marks of one of the Emerson Process Management family of companies All other marks are property of their respecl ive owners The Daniel UltraSonic Gas Flow Meter including Mark III electronics is covered by US Patents 598330 and 4646 575 and patents pending The contents of this publication are presented for information purposes only and while effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or thel( use or applicability Daniel does not assume responsibility for the selection use or maintenance of any Daniel product Responsibility for proper selection use and maintenance of any Daniel product remains solely wilh the purchaser and end-userAII sales are governed by our terms and conditions which are available upon request We reserve the right to modify or improve the designs or specification of our products at any time without notice

-- -~J ~~--------- EMERSON bull ~ I

copy2004 Daniel Measurement and Control Inc All rights reserved Printed in the USA DAN -GFM-DS-0221-rev0404

reg DAN-3MT-3M-0801 -~I August 2001_-shy

3 SectioQltandProfiler Meter Tubes ~ Pf~6 5 ~~ IrMimiddot~

Instruments You Can Trust Daniel Meter Tubes are more than just fabricated pipe with an orifice fitting They are accurate dependable instruments because of Daniels dedicated approach to quality Extra steps taken during every phase of meter tube design and production separate Daniel Meter Tubes from all the rest

The Daniel 3 section meter tube is available with any style Senior or Junior orifice fitting Simplex plate holder or orifice flanges The assembly contains an inlet spool of the minimum length prescribed by the 143 standard The second section begins with a concentric flange mounted tube bund=1 leetln9 the 2000 API 143 requirements and a W thick spacer plate to ease tube removal for inspection The 04~r end of section 2 conshytains the orifice flange or fitting The third or downstream section follows and contains 2 branchOonnections and is extra long to allow for the addition of extra branch conshynections in the field If desired The standard meter tube has flanged outer ends Other end connections are avaUable on request

Inspectionffesting= Daniel maintains rigid inspection procedures during manufacturing of meter tubes Micrometer and internal surface roughness readings are recorded and supplied with each meter tUbe Customer or third party inspectors are welcome to verify these readings Radiography of welds is another service that is available

Fabrication Fabrication of your instrument Includes attaching the orifice fitting to the meter tube to make an integral primary measuring element For welding operashytions Daniel uses automatic welding machines and rotatshying positioners Highly skilled code qualified welders are employed to tum out highest quality on each job Special internal jigs and fixtures are used to insure smooth Inlet and outlet surfaces without steps or offsets All welds receive expert grinding by experienced craftsshy

men X

cl

-

gt shy

~

-

J ~

Features bull Dowel pin alignment close tolerance maleffemale

flange or knock out dowel pins insure that the bores of sections two and three are matched without offsets

One 1h and one 0 branch connection on the downstream for thermowell or other uses standard

Beveled flanged or reduced ends as well as any available weld fitting can be furnished on the ends of the tubes

Hydrostatically tested after manufacture

Each orifice fitting is tested for tap hole and orifice plate seal integrity after the meter tube has been pressure tested

Material Selection Daniel uses special cold drawn seamless tubing or honed pipe in the fabrication of meter tubes The strict reqUirements for intemal roundshyness and surface finish preclude the use of standard commercial pipe in most cases Daniel maintains a large inventory of this special pipe to rapidly complete your order

LT

EMERSON~ ltocess Management

~~------------------------------------------------------------~------------------------------

Raised Face Weld neck

NA

3M-30RW

3M-60RW High Pressure

3M-90RW 3M-150RW 3M-250RW

DAN-3MT-3M-0801 August 2001

3 Section Meter Tube Catalog Numbers 2-12 with Senior Fitting 10 amp 12 with Junior Fittina

~

Pressure Rating

150

Flange by Weld

(Flangnek)

3M-011

Flange by Flange

(Flanged)

3M-101

Weld by Weld

(Weldnek)

NA

Flange by Weld

(Flangnek)

3M-021

Flange by Flange

(Flanged)

3M-201

Weld by Weld

(Weldnek)

NA

300 3M-013 3M-103 NA 3M-023 3M-203 NA

600 3M-015 3M-105 3M-185 3M-025 3M-205 3M-285

H~h Pressure 3 Section Meter Tubes 900 3M-016 3M-106 3M-186 3M-026 3M-206 3M-286

1500 3M-017 3M-107 3M-187 3M-027 3M-207 3M-287

2500 3M-018 3M-108 3M-188 3M-028 3M-208 3M-288

2middot8 with Simplex 2middot12 with Orifice Flanges Flange byPressure

WeldRating Weld by Weld (Flangnek) (Weldnek)

150 3M-071 NA 3M-073300 NA

600 3M-075 3M-705 High Pressure

3M-7063M-076900 3M-7071500 3M-077 3M-7083M-0782500 -

Two Section Meter Tubes When Usmg Weldnek Flttmgs

Senior and Simplex fittings are also available in 10000 psi rating in some sizes All units are also available with Ring Type Joint (RTJ) flanges on request Sizes larger than 12 available on request

PackingShipping Daniel bolts together all meter A SPECIAL NOTE The use of factory original Daniel tubes when size permits before shipment This saves parts will assure your Senior Junior and Simplex Orifice the user time and field labor costs Fittings are protectshy fittings will stay within original specifications and operate ed by heavy lumber and the tube flanges by special-cut properly protectors

PaintingCoating The Daniel standard paint is a basic enamel type Special coatings such as multi-coat

offshore systems are available on request

3~Section Meter Tube with Tube Bundle

~-----~ U ----~---------~=~~middotmiddotmiddotmiddot~middot t)middotmiddot-middot ~- - -0bull )00)00 1

I~IC--middotmiddotmiddot-middot -----shyshy-bullmiddotV ------- ~

~ - ~-

~

ii~pound bullbullbull ~

Standard lenAths Size un Upstream 0 Downstream V (vane location)

3 7-5 4-0 130 4 9~~9 4-0 130

6 14-8 5-0 t30

102410 60middot middot 130 1~ +1 2tYS Tq 130 JiIf

Note Straightening vanes are not available in 2line size (See Dald Profller DAN-1852middot 2M)

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Daniel meter tubes can be supshyplied in many combinations and configurations Any of the orifice fittings plate holders or orifice flanges can be included in a meter tube Each 3 section standard meter tube is equipped with a flange mounted tube bundle straightener In accordance with April 2000 API 143 and a 1h thick spacer to facilitate tube removal for inspection Downstreams are longer than minimum required to allow for field Installation of additional branch connections If required

To specify a 3 section meter tube use the designation 3M followed by the type orifice holding deVice Ex 4 600 3 section meter tube with flanged ends using a Senior fitting flangneck style is specified as 4-3M-015 The same unit with a weldneck style Simplex is specified as 4middot3M-705 When ordering specify pipe schedule and end configuration Larger size and custom meter tube designs are available on request

The Daniel Profilertrade three section meter tube is availshy lows and contains 2 branch connections Other or addi able with any style Senior or Junior orifice fitting Simplex tiona I connections can be supplied in this section on plate holder or orifice flanges The assembly contains an request These meter tubes are for use in any piping conshyinlet spool of tile minimum length determined during testshy figuration with beta ratios to 67 Downstream sections ing to the API 143 standard The flange union between are extra long to allow for the addition of extra branch the first and second sections contains the ProfilerN and connections in the field if desired The standard meter a Y2 thick spacer plate to facilitate tube removal for tube has beveled outer ends Flanges or other end conshyinspection The outer end of section 2 contains the orishy nections are available on request fice flange or fitting The third or downstream section fol

Meter Tubes Catalog Numbers - 2 WI emor In9 bull Wit un or Itt ng2 1 th S Fitt 10 amp 12 h J i F i

Pressure Rating

Flange by Weld

(F1angnek)

Flange by Flange

(Flanged)

Weld by Weld

(Weldnek)

Flange by Weld

(Flangnek)

Flange by Flange

(Flanged)

Weld by Weld

(WeJdnek) 150 M011 M-101 NA M-021 M-201 NA 300 M-Q13 M-103 NA M023 M-203

NA 600 M-015 M-105 M-t85 M-025 M-205 M-285

2middot8 with Simplex 2middot12 with Orifice Flanges

Pressure Rating

Flange by Weld

weld by Weld

(Weldnek)CFlananekl 150 M-071 NA 300 M-073 NJA 6QfJ M-()75 M-705

Raised Face Weld Neck

NA - -

lM-30RW M-60RW

Two Section Meter Tube When USing Weldnek Fittings

Consult Factory for High Pressure Applications

PROFILERTM Flow Conditioning Plate

The Profiler has been tested and Shown to be in full compliance with the requirementS of API 143 April 2000 The Profiler both removes swirl

the tube bundle Available In flange mounted model only Also available In RTJ style on request

and creates a fully developed flow profile at the orifice Use of this unit allows shortened upstream straight pipe lengths of 17 diameters Beta ratio limit is 67 as with

-~---

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 3: Medidor de Flujo

lt0 ~I ISO 90012000AZIECA CERTIFle ADQ

CORPORACIU~ c unwcrOR SEMBRANDO ISO 9000

scombustible 20 de Octubre del 2004

Partida cantidad Descripcion 02 1 bull Aislamiento Optico Cada entrada y cada salida esta foto-opticamente aislada con un

maximo de rechazo de modo comun en entradas y salidas de plusmn 250 VDC a tierra del chasis

bull Sistema de autodiagnostico Monitorea y alarma las siguientes condiciones

Estado del sensor multivariable en Presion estatica Presion diferencial y Temperatura

Estado de la entrada digital

Estado de las salidas de contacto

Estado de la entrada de frecuencia

Temperatura intema

Valores de voltaje intemo y de Ia bateria

bull Comunicaciones Un puerto serial RS232 0 RS485 velocidad de transmision de 1200 a 9600 BPS protocolo MODBUS RTUASCII Y un puerto serial RS232 velocidad de transmision de 1200 a 9600 BPS protocolo MODBUS RTUASCII

bull Elementos primarios de medicion compatibles Diferencial Placa de orificio V Cone Wedge Annubar Venturi De pulsos Turbinas PO Vortex Ultrasonicos Masicos

bull Unidades de Ingenierla US y Metrico bull Ecuaciones para caiculo de flujo AGA 3 API 143 AGA 7 AGA 9 Y AGA 8 Metodos 12

y detallado API 56 API5 API 2540 API11-2-1 API11-2-2 Todos los calculosreporteshist6ricosalgoritrnos etc En acuerdo a los lineamientos del API Capitulo 211

Sensor Multivariable MOdulo multivariable 3 en 1 modelo 205 de Rosemount Cuenta con Ia tecnologia de oolda de capacitancia para sensar la presion diferencial sensor piezoresistivo con silicon para sensar la presion estatica y una entrada para RTD que se encarga de sensar la temperatura Sensor de Presion Diferencial Rango desde 0-250 pulgadas de H20 Con una exactitud del plusmn 0075 del span para spans desde 11 a 101 del URL que incluye los efectos de linealidad histeresis y repetibilidad

Sensor de presion absolutal manometrica Rango desde 0-3626 PSI Con una exactitud del plusmn 0075 del span para spans desde 11 a 101 del URL que incluye los efectos de linealidad histeresis y repetibilidad

Sensor temperatura de proceso Es compatible con cualquier tipo de RTD de Platino100 Ohms de 23 0 4 hilos Con un rango de -40a C a 6490 C con una exactitud de plusmn 056deg C que incluye los efectos de linealidad histeresis y repetibilidad

Corporacion Constructora Azteca SA de 01 I Protectotank Draz Miron 80S Col Centro CP 96400 Coatzacoalcos Ver Tel (01921) 212122021215042126517 Fax (01921) 21 2 24 51

e-mail cramosprotectotankcommx sitio web wwwprotectotankcommx

m ISO 9001 2000 CERTIFIC AOQ

20 de Oetubre del 2004

Partida Cantidad Oeseripelon 02 1 bull Materiales de eonstrueeion del modulo multivariable

Conexiones a proeeso ~NPT con distaneia entre centros de 218 Partes humedas Diafragma de Hasteloy C (para manejo de gas amargo NACE

MR-01-75) Bridas Acero Inoxidable 316 Anillos de las partes humedas De teflon con alma de vidrio Partes no humedas EI fluido de lienado es Aeeite de silicon anilos de Buna N

Incluye

Un kit de montaje de Acero Inoxidable 316 para pedestal de 2 Un manifold de 5vias de Acero Inoxidable 316 de de diametro para una presion

maxima de 10 000 psi (700 Bar) Software de programaeion gratuito (Ambiente Windows) Embalaje apropiado para embarque a destino marino Documentos ineluidos Certificado de materiales Garantia de operaeion Hojas de

datos rellenas Manuales de mantenimiento operacion y eonfiguracion (en ingles) Lista de partes de repuesto Certifieado de pruebas de planta Certifieado de ealidad Protocolo de pruebas y ealibraeion Certifieado de Calibraeion de la planta

Precio Unitario $ 530000 usn +IVA

Terminos comerciales 1 Validez de la oferta 90 dfas 2 Tiempo de entrega 120 dfas 3 Forma de pago 30 dfas presentacion factura 4 Garantfa de caUdad 12 meses de operacion 018 despues del embarque 5 Precios fijos en dolares arnericanos + NA 6 Embalaje adecuado tipo marino 7 LAB su almacen PEP Cd Del Carmen Campeche

1 Atentam nte

Ing Carlos Manuel Ramos Yeh Corporaci6n Constructora Azteca SA de cv

cramosprotectotankcommx Auxiliar de gerencia

Corooracion Constructora Azteca SA de CV I Protectotlnk Diaz Miron 805 Col Centro c P 96400 Coatzacoalcos Ver Tel (01921) 212122021215042126517 Fax (01921) 21 2 2451

e-mail cramosprotectotankcommx sitio web wwwprotectotankcommx

-- - -

- - -

- - -

V -Conereg Preliminary Sizing

Description ~-cone 8 CSS316 Cone S80 ANSI WN CL600 RF

1000 Fa - aPE D67e-06 d 67e-06

Pv

HL I 210 inWC

~ Entered value Table based on one flow condition (P T Z k ) V25 Version 41

Record Start Date 10-18-2004

Print Date 10-20-2004 ~ McOOMEIER L _ _ _ _ _

By Corporacion Constructora Azteca SA de CV

Fluid

Serial Fluid State

End User Job Ref

IndustryModel

Tag I Gas Combustible r-

f--shy

VW08FF 16N-BAZ

NATURAL GAS 174mw

GAS

CPTG ATASTA

PEP

Note r-085

I kgcm2Gr30 degc

2444 Ibft3

1135e-02 cP -

p

G 06008

Z 09172

Y 09918 c-- - - shy

k I 1302

8573 Cp

Mw 17400

14 696 psi -

OF60000

I 09979 I I 14696 psiPbaro

Pc I 66720 psi

of-11657Tc

----------------------------------------------------------------~

q max Flowrate 50000000 SCFD

6977e+06

34 22 fps

28208 inWC

01110 inWC

7636 in

6820 in

04498

50

McCrometer Cal

Third Party Cal Re max Reynolds

Dye Pen Exam V max Velocity

Hydro Test ilP max Dp

ilP min Dp X-Ray Exam

D Meter 10 Mag Part

d Cone OD PMI

p Beta Ratio CMTR Copies

Turn Down Application Eng

I--- shy

CMRY

Velocity Gas Exp ilP Flowrate

Re fps Y inWC SCFD

1 6977e+06 3422 09918 2821 50000e+07

2 6217e+06 3049 09935 2232 44556e+07

3 5458e+06 2676 09950 1715 39111e+07

4 4698e+06 2304 09963 1267 33667e+07

5 3938e+06 1931 09974 8885 28222e+07

6 3178e+06 1559 09983 5777 22778e+07

7 241ge+06 1186 09990 3341 17333e+07

8 165ge+06 8136 09995 1570 1188ge+07

9 8993e+05 4410 09999 4610 64444e+06

10 1395e+05 06843 1000 01110 10000e+06

File Gas Combustible ATASTAv25

yeoNE reg CONFIGURATION SHEET

PRECISION TUBE SERIESMODELVW (H)

ANSI 8165 Weld Neck Raised Face Flanges - Class 600 or 900

DESCRIPIION AND GENERAL PERFORMANCE SPECIFICATIONS The V -Conereg flowmeter is a patented differential pressure type flow measurement device A cone is positioned in the center of the pipe to increase the velocity of the flowing fluid and create a differential pressure This pressure difference can be measured and used to accurately interpret flowrate Two taps are provided on every V -Cone to allow sensing of the high and low pressures A typical V-Cone application can follow these general performance specifications bull Accuracy up to plusmn05 of rate Model VW Bulletins

ANSI 8165 Weld Neck RF Flanges 24509-35 Class 150 or 300

bull Repeatability plusmnO J bull Turndown 10 1 24509-36 Class 600 or 900 bull Standard Betas 045 through 085 24509-37 Class 125 or 250 bull Headloss Percentage of differential pressure produced varies with beta ratio bull Installation Typically 0-3 diameters upstream and 0-1 diameters downstream Each V -Cone is sized for the intended a Ii cation S ecific erformance ratin s must be obtained throu

MODEL VW(H) DIMENSIONS

H L 2 1 8 (Note 2) B1- ~WE-D DC

~ I -rr --- - T - III

Lk-l - -- -- c-ttt- -- - -- -- - -- -

- - --- --- ---

I

--------------A------------~-t I A lor to 1 1lor to 24

DIMENSION TABLE

I

Size ANSI B165 Class 600 ANSI B165 Class 900 Stainless Carbon

0 E (Note 2) A (Note 1) B A(Note 2) B C (Note 2) C (Note 2)

inch inch mm inch mm inch mm inch mm inch mm inch mm inch mm NPT

y 1225 3112 563 1430 1288 3272 594 1509 0622 158 - - 084 213 Y Y 1263 3208 582 1478 1363 346 2 632 1605 0824 209 - - 105 267 Y 1 1300 3302 601 1527 1388 3526 644 1636 1049 26_64 gtshy - - 1315 334 Y 1Y 1550 3937 576 1463 1650 419 1 626 1590 1645 4178 - - 19 483 Y 2 1763 4478 631 1603 1988 5050 744 1890 2104 5344 - - 2375 603 )I

2)1 1800 4572 650 1651 2000 5080 750 1905 2504 6360 - - 2875 730 Y

3 2025 5144 663 1684 2175 5525 738 1875 3104 7884 - - 35 889 )I

4 2375 6033 788 2002 24 75 6287 838 2129 4090 1038 - - 45 114 Y

6 3100 7874 875 2223 3275 8319 963 2446 6065 1541 6065 1541 6625 168 Y

8 3600 9144 1001 254 3 3825 971 _6 1113 2827 7981 2027 7981 2027 8625 219 )I

10 3950 1003 1076 2733 4200 1067 1201 3051 1002 2545 1002 254 5 1075 273 Y

12 4175 1060 1113 2827 452 5 1149 1288 327 2 1200 3048 1194 3033 1275 323 Y

14 4225 1073 1213 3081 4600 1168 1400 3556 1325 336 6 1313 3335 14 355 Y

16 4325 1099 1263 3208 4625 1175 1413 3589 1525 3874 1500 3810 16 406 Y

18 4575 1162 1288 3272 4925 1251 1463 371 6 1725 438 2 1725 4382 18 457 Y

20 5025 )11276 11 1313 3335 5475 1391 1538 3907 1925 4890 1925 4890 20 508 Y

24 6325 1607 1763 4478 7025 1784 2113 536 7 2325 5906 2325 5906 24 609 Y 1 Overall length (A) tolerance vanes With line size jYto 1 plusmn18 (plusmn4mm) 1 jYto 10 plusmn316 (plusmn6mm) 12 to 24 plusmn14 (

2 Typical values shown

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-68111 Fax (909) 652-3078$ MQ[)MEIER Web Site httpWlNwmccrometercom e-mail infomccrometercom

Lit24509-36 Rev 146-00 copy2000 by McCrometcr Inc Printed in USA

I bull

CONFIGURAIiON SHEET MODEL NUMBER CONFIGURATION VW(H)

Pipe Size Materialsj Schedule FittingsEnd Connections

VW Q A 10OA S304V2 JLj CL 600 RF WN LtJ NPT

OB L S304L B 20 17 CL 900 RF WN S Socket 01 1 A S316L C Bored

Scvcmllypcs of ICS Tube amp Flanges 0 StdOC 1V2 ~ fittings aV01ilablc

2 40 00

S304 Cone Support amp Couplings E02 Epoxy Coated Blue (excluding cone) F 80

03 2V2 3 r-u CS Tube amp Flanges J 100

04 4 S304 Cone Support amp Couplings 120K jOther materials can include6 Coating Painting Per Customer Req 14006 L

-shy HASTELLOY C-276 S321H8 G 160 DUPLEX 2205 INCONEL 625

08 10 XXS

CHROMEMOLY P22PII 10 H

10S MONEL K400K500

12 M12 14 P XS

CARBON STEELS 14

16 -- shy

A350 A333 AP15L A 106B 16

18 20 18

20 24~

Example VW10AE16N V-Cone 10 inch line size S316L schedule 40 pipe ANSI CL 600 RF WN flanges V2NPT fittings

Type

STANDARD PIPE SCHEDUIpoundS Stainless Steel Carbon Steel

Size Std Size Std to 4 C

6 to 10 E 12 and up 0

6 to 16 18 and up

E 0

Pipe up to 8 utilizes seamless pipe Above 8 is welded pipe

ABBREVIATIONS ASME American Society of Mechanical Engineers NPT National pipe taper SS Stainless steel RF Raised Face CS Carbon steel WN Weld Neck

Technical questions can be answered through a local representative or through our application engineers

REPRESENTED BY

MANUFACTURING STANDARDS McCrometers welders and welding procedures are qualified in accordance with ASME Section IX All meters are visually inspected for weld defects Specific customer requirements can be complied with upon request

The welding can be in accordance with

bull ASME Section VIII

bull ASME B311

bull ASMEB313

Non-destmctive testing can include

bull Hydrostatic Pressure Testing

bull Penetrant Examination

bull Radiographic Examination

bull Positive Material Inspection

bull Magnetic Particle Examination

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-6811 Fax (909) 652-3078 Web Site httpwwwmccromelercom e-mail infomccrometercom

Lit24509-36 Rev 146-00 copy 2000 by McCrometer IncPrinted in USA

~----------------------~---------------------------------------------------------------------------

V -Cone Installation Guide Upstream and Downstream Minimum Straight Pipe Run Requirements

For Liquid Metering and Gases at a Reynolds Number (Re) Value Less Than or Equal To 200000

For fl greater than or equal to 065 add ID

Obstruction DownSize Range Up Stream Stream

I Elbow OD

2 Elbows

OD

OD OD

Tees OD OD Not Preferred ValveAll Sizes Butterfly Valve (control valve) DownstreamPosition

3D 3D

Butterfly Valve (shutoff valve) 3D OD

Full port Ballvalve (shutoff) OD OD

Heat Exchanger (Depends on Type) OD OD

Expander (067D to D) over a length ID ID of 2SD

Reducer (3D to D) over a length of ID ID 3SD

Note The meter and adjoining pipe should have equal IDs

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-6811 Fax (909) 652-3078 ~ MCOOMEIER Web Site http wwwmccrometercom e-mail infomccrometercom

Lit24S09-21 Rev 10102-04 copy2004 by McCrometer InclPrinted in USA

Product Data Sheet DAN-GFM-DS -21-rev0404 ( )

April2004 SeniorSonic with Mark TM Electronics

- SeniorSonic The Daniel SeniorSonic Gas Flow Meter with Mark IWM Electronics saves you time and money Lost and unaccounted for gas is reduced by exceptional low and high flow accuracy and linearity throughout the calibrated flow range Time is saved by a best-in-class audit trail Mark III Electronics can pinpoint alarms events and configuration changes in a matter of seconds Best of all operating the Daniel SeniorSonic gas flow meter is easy with the Windowsreg based Daniel Customer User Interface (CUI) software

Features middot Excellent long-term performance

Velocity Range Most sizes are rated to performa at 100 fps middot Full electronic audit trail (exceeds API 211) Over-range of up to 125 fps and in some cases beyond 125 middot Exceptional low and high flow performance

middot Bi-directional multi-point calibration coefficients fps in emergencymiddot situations and without transducer failure

middot Rangeability exceeds 50 1 with calibration Availability is limited by line size and ANSI rating Visit middot ANSI 30060090015002500 versions wwwdanielcomseniorsonic for additional information middot Extractable transducers (For all sizes) middot Minimum upstream piping requirements Meter specifications

Gas temperature -4 to +212deg F (-20 to +100deg C) Easy to learn and use CUI software features Operating pressure range 150 - 3750 psig middot Comprehensive monitor screen (1030 - 25855 kPa) Consult factory for lower and middot Field start-up wizard higher pressure applications middot Calibration wizards (analog and frequency) Flanges RF for 3001500 RTJ for 6002500 middot Flow calibration configuration wizard middot Audit 1 alarm 1history retrieval Power DC version - 1224 (11-36) VDC 6 watts maximum middot Digital waveform viewing middot Maintenance log summary in ExcelI Environmental middot Built-in AGA 10 SOS calculator Operating temperature -40 to +149deg F (-40 to +65deg C) middot Automatic file naming Operating relative humidity up to 95 non-condensing middot Trending of maintenance logs Storage temperature -40 to +185 0 F (-40 to +85 0 C) middot Configuration comparison with exception summary middot Remote dial-up support and Ethernet support Typical Applications middot Unlimited meter directory support middot Custody transfer

middot Power plants Specifications middot Large industrial users

Electronic unit middot City gates Communication protocol Modbus RTUASCII amp TCPIIP middot Production Two serial RS-232485 ports and Ethernet middot Underground storage sites Communication speed Up to 115 KBPS middot Offshore Frequency outputs Four Frequency range 0-10005000 Hz Safety classifications Digital output Selectable (up to four for data valid or flow UL listed for use in Class I Division 1 Group D hazardous

direction) locations in both the US and Canada (UL E152246) Calculation update time Configurable for 14 and 1 second CE marked to ATEX directive (949EC ) (pending)

Certified to Eex d ia liB T4 to standards EN 50014 EN 50018 Accuracy and EN 50020 (pending) Flow calibrated accuracy plusmn 01 (Relative to lab) Absolute accuracy Including lab uncertainty about 03 Repeatability plusmn 02 of reading for Ot to Omax

-- - tI II~ EMERSON ~-----

wwwdanielcom

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Recommended Ma~jum Flow Velocity Meter Size J Meter Size Metric Max Inches Max ftI~ m tris

4 100 100 30 6 100 150 30 8 100 200 30

10 80 250 24 12 80 300 24 16 85 400 26 20 85 500 26 24 85 600 26 30 70 750 21 36 70 900 21

Dimensions These measurements are meant only as an aid in the design of metering systems Consult Daniel engineering drawings prior to construction

Typical 600 ANSI Meter with 45 Degree-Angled Transducers Overall End- Flange Approximate Overall End- Flange Approximate

Meter Size To-End Diameter Weight To-End Diameter Weight (Inches) (Inches) (Inches) (Pounds) (Millimeters) (Millimeters) (Kilograms)

4 2900 1075 370 737 273 168 6 2950 1400 460 749 356 209

8 3150 1650 650 800 419 295 10 3400 2000 885 864 508 402 12 3544 2200 1075 900 559 489 16 4400 2700 1955 1118 686 889 18 4531 2925 2800 11sect1 743 1273 20 5062 3200 30Z5 12amp6 84~ 1398

0 4 5862 3700 404~ 1489 940 1839 30 6700 4450 4925 1702 1130 2239 36 7350 5175 6425 1867 1314 2920

()l p l ( C flO

bull I iY0

e

Page 2

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 60 F and gas composition These values are intended to be a guide in Contact Daniel engineering for a specific application

_ Flow Rates (JIISCFHl Basea Upon 100 ftls PSIG 4 6 8 10 12 16 20 24 30 36 100 247 561 971 1532 2174 3432 5398 7807 12607 18154 200 468 1065 1845 2908 4127 6515 10248 14822 23935 34467 300 696 1584 2743 4325 6137 9690 15240 22043 35596 51258 400 931 2118 3668 5782 8206 12955 20377 29472 47593 68534 500 2667 4619 7282 10334 16315 25661 37114 59934 86305 600 1421 3232 5597 8823 12522 19770 31095 44973 72626 104582 700 1676 3813 6602 10409 14772 23322 36682 53055 85677 123374 800 1938 4409 7635 12036 17082 26968 42417 61349 99070 142661 900 2207 5021 8694 13706 19452 30710 48302 69861 112816 162455 1000 2482 5646 9777 15414 21875 34536 54320 78565 126872 182696 1100 2763 6286 10885 17161 24355 38451 60478 87471 141254 203405 1200 3050 6939 12015 18943 26883 42443 66756 96551 155917 224521 1300 3341 7602 13164 20753 29453 46500 73137 105781 170822 245983 1400 3637 8274 14327 22587 32055 50608 79599 115127 185915 267718 1500 3935 8953 15504 24442 34688 54765 86137 124583 201184 289706 1600 4235 9635 16685 26305 37331 58938 92700 134076 216515 311781 1700 4536 10321 17871 28175 39986 63128 99291 143608 231908 333948 1800 4836 11002 19052 30036 42627 67298 105850 153094 247227 356006 1900 5134 11681 20226 31888 45255 71448 112376 162534 262471 377958 2000 5429 12350 21386 33716 47849 75543 118818 171851 277516 399623

Flow Rates (MIfIISCFfJ) Based Upon 100 ffls PSIG 4 6 8 10 12 16 20 24 30 36 100 59 135 233 368 522 824 1295 1874 3026 4357 200 113 256 443 698 990 1564 2459 3557 5744 8272 300 168 380 658 1038 1473 2326 3658 5290 8543 1230 400 224 508 880 1388 1969 3109 4890 7073 1142 1645 600 282 640 110~ 1748 2480 3916 6159 8907 1438 2071 600 342 776 1343 2118 3005 4745 7463 1079 1743 2510 700 403 915 1685 2498 3545 5597 8804 1273 2066 2961 800 466 1058 1832 2889 4100 6472 1018 1472 2378 3424 900 531 1205 2087 3289 4668 7370 1159 1677 2708 3899

1000 597 1355 2346 3699 5250 8289 1304 1886 3045 4385 1100 665 1509 2612 4119 5845 9228 1451 2099 3390 4882 1200 734 1665 2884 4546 6452 1019 1602 2317 3742 5389 1300 804 1824 3159 4981 7069 1116 1755 2539 4100 5904 1400 875 1986 3438 5421 7693 1215 1910 2763 4462 6425 1500 947 2149 3721 5866 8325 1314 2067 2990 4828 6953 1600 1019 2313 4004 6313 8960 1415 2225 3218 5196 7483 1700 1091 2477 4289 6762 9597 1515 2383 3447 5566middot 8015 1800 1164 2641 4572 7209 1023 1615 2540 3674 5933 8544 1900 1235 2803 4854 7653 1086 1715 2697 3901 6299 9071 2000 1306 2964 5133 8092 1148 1813 2852 4124 6660 9591

Calculating meter capacity To calculate a volume rate for a given velocity multiply the capacity in this table by the desired at the pressure and divide the answer by 100 Example Determine the hourly flow rate al 70 fps for an 8 inch meter operating at 800 psig Volume =7635 MSCFH Velocity 70 Answer = 763570100 = 5344 MSCFH

Pa~e 3

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 20 F and gas composition These values are intended to be a guide In Contact Daniel nee ring for a application

Flow RateS (IASOFH) Based UppJ1 30 mls Schedule 40) kPag 4 6 8 10 12 16 20 24 30 36 1000 967 2201 3811 6007 8527 1346 2117 3062 4945 7121 1500 1422 3234 5600 8827 1253 1978 3111 4500 7267 1046 2000 1885 4289 7428 1171 1662 2624 4127 5969 9639 1388 2500 2359 5367 9294 1465 2079 3283 5164 7469 1206 1737 3000 2843 6468 1120 1765 2506 3956 6223 9000 1453 2093 3500 3337 7592 1315 2072 2941 4644 7304 1056 1706 2457 4000 3841 8739 1513 2385 3386 5346 8408 1216 1964 2828 4500 4356 9910 171S 2705 3840 6062 9535 1379 2227 3207 5000 4881 1111 1923 3031 4303 6793 1068 1546 2495 3593 5500 5417 1232 2134 3364 4774 7538 1186 1715 2769 3987 6000 5962 1 3702 5255 8297 1305 1887 3048 4389 6500 6517 1483 2568 4047 5745 9070 1427 2063 3332 4798 7000 7082 1611 2790 4398 6243 9856 1550 2242 3621 5214 7500 7656 1742 3016 4754 6748 1065 1676 2424 3914 5636 8000 8238 1874 3246 5116 7262 1146 1803 2608 4212 6065 8500 8828 2009 3478 5482 7782 1229 1932 2795 4513 6499 9000 9425 2144 3713 5853 8308 1312 2063 2984 4818 6939 9500 10028 2281 3951 6227 8839 1396 2195 3175 5127 7382

10000 10636 2420 4190 6604 9375 1480 2328 3367 5437 7830

Flow Rates (IANSOND) Based Upon 30 mls (Scnedule 40) PSIG 4 6 8 10 12 16 20 24 30 36 1000 0232 0528 0915 1442 2046 3231 5082 7350 11869 17091 1500 0341 0776 1344 2119 3007 4748 7468 10801 17441 25116 2000 0453 1029 1783 2810 3989 6297 9904 14325 23133 33311 2500 0566 1288 2231 3516 4991 7879 12393 17924 28946 41682 3000 0682 1552 2688 4237 6014 9495 14935 21600 34882 50230 3500 0801 1821 3155 4973 7059 11145 17530 25354 40943 58958 4000 0922 2097 3632 5725 8126 12830 20179 29186 47131 67869 4500 1045 2378 4119 6492 9215 14549 22883 33097 53447 76963 5000 1171 2664 4615 7275 10326 16302 25641 37086 59889 86240 5500 1300 2957 5121 8072 11459 18091 28454 41154 66458 95699 6000 1431 3254 5637 8885 19912 31319 45298 73150 105336 6500 1564 3557 6162 9713 13787 21767 34236 49517 79964 115148 7000 1700 3866 6696 10555 14982 23653 37203 53808 86893 125126 7500 1837 4179 7239 11410 16196 25570 40218 58168 93934 135265 8000 1977 4497 7789 12278 17428 27515 43277 62592 101078 145553 8500 2119 4819 8347 13157 18676 29485 46376 67075 108318 155978 9000 2262 51 8912 14047 19939 31479 71611 115642 166524 9500 2407 5474 9482 14945 21214 33492 52679 76191 123038 177175

10000 2553 5805 10056 15851 22500 35522 55871 80808 130494 187911

Calculating meter capacity To calculate a volume rate for a given velocity the capacity this table by the desired velocity at the operating pressure and divide the answer 100 Determine the hourly flow rate at 30 mps for an 8 inch meter at 4500 Volume 1716 Velocity 10 Answer 17161030 5719 MSCMH

Product Oata Sheet DAN-GFM-DS-21-rev0404 April 2004

The drawings below represent recommended piping lengths for various flow conditioners when installed with the Daniel SeniorSonic flowmeter If shorter lengths are used there may be an increase in flow measurement uncertainty

Piping Recommendation For SeniorSonic With No Flow Conditioner

1~~--------------------200 -----------------------~

Q----I__------shy~

J ~~f --M-I-middotn-im-~-~-p-iP-i-n-g-R-e-c-o-m-m-e-n-a-a-tl-o-n-F-o-r-S-en-I-o-r-S-o-n-ic-W-it-h-D-a-n-ie-l-p-r-O-fi-le-r-o-r-C-p-~-5-0-E~-F--o-w-c-o-n-d-itl-io-n-e-r--

1 00 middot -2 o~o ~1gt

[ _____ ---Al11~ ----- =ul [II I

I 0 0 a It Minimum Piping Recommendation for Bimiddotdirectional SeniorSonic

with Daniel Profiler or CPA 50E Flow Conditioner

~------- 100 ------t ~------- 100 ----~ - 50---shy

3middot 50

-- 50 ---shy

3middot 50

~ -

A WARNING Do not operate this instrument in excess of the specifications listed Failure to heed this warning could result in serious injury andor damage to the equipment

Page 5

---- - --- _ --- ----------------- -------------------------shy

--iI

-------~~--------1

----~----------------I _____________________I

----~------~----__i _____bullmiddot________ ----__i

____________shy____~__i

____________________---i __________________

_________shy__________~~

~ I ~

I

~

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

8

10

12

16

20

24

30

36 r

ANSI Class 300 600--~------------------------i

900__________----__------__------i 1500

-------------------------------~ Flange Raised Face (RF) _________________-_------j

Ring Type Joint (RTJ)___---------__bull-_____Imiddot

Materials Standard ~----~~--~----~--------~~ Stainless Steel

DJplex --~--------------------------~----~ _________________________--____~__

Device Type

Electronics

Transducers

Meter Size (Inches)

Daniel Ultrasonic Model Number Selections ES-21055 RevW

SeniorSonic (4-Path) ---------------1 JuniorSonic (1~Path) ------------1 JuniorSonic (2-Path) ______________

Mark II UL 24VDC 4-20rlA 3NPT

Mark UL 24VDC 1middot5VDC 3NPT ---------------------1 Mark CENaEC 24V DC 4-20mA M20 --------------_--__1

Mark IICB-JELEC24VDC1-SVDCM20

Mark II ClNELEc 24VDC 4-20mA M20 Rerrote

Mark II CENELEC 24VDC 1-5VDCM20 Rerrote

MarkU UL 24VOC4-20mA 3NPT Rerrote_

Mark II U~ 24VDC l-SVPG 3NPT Rerrote

Mark IIIUL 34 NPT

Mark III UL 34NPT Rerrote

TmiddotSlo T-12

4

middot 6

Page 6

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Systems Daniel Measurement and Control is the industry leader in designing constructing and commissioning of complex oil and gas metering systems to exacting standards

This global organization offers decades of petroleum fiscal flow measurement application experience Customers rely confidently on Daniels Systems Group international fabrication facilities customized engineering and its successes in field-testing and support From the simplest single-stream skid to complex on-site installations Daniel Systems delivers both natural gas and liquid petroleum tumkey applications Daniel Systems designs constructs and commissions the metering project blending up-toshythe-minute technology with decades of understanding what customers need and expect

Components of a Daniel Systems installation typically include meters valves provers flow-control instruments instrumentation and read-out equipment and process management components

Computer software and hardware are integrated with the measurement system Standard calculation methods include AGA3 (now API-MPMS-143) ISO 5167 AGA578 AGA9 and the API Manual for Petroleum Measurement Standards

Daniel DMSS-2000 Supervisory Control Systems utilize a sophisticated Graphical User Interface database server and a dedicated PLC for the metering skidMOV interface Redundancy is often used for custody transfer systems andor when system integrity is essential

A dedicated Project Manager and Project Team are assigned to each measurement system project This team is responsible for overall system design and project construction from start to finish A separate internal QAQC group reviews all design detailS inside and outside fabrication assembly and system testing

Whether it is a pipeline offshore production facility or a loading facility for ocean-going tankers the Daniel Systems group is a proven single-source solution for customers throughout the world

Page 7

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Daniel Measurement Services Daniel Measurement Services takes pride in being there after needs arise with the right solution for customers with gas and liquid fiscal flow measurement applications

Around the clock and around the world Daniel Measurement Services has experienced highly qualified people prepared to help customers who need assistance with the following

middot Start-up and commissioning middot Preventive maintenance middot Product repair I upgrades middot Project management and integration middot Meter Tube inspection and recertification middot Remote diagnostics middot Warranty Plus middot Technical training

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880

Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337

Stirling Scotland - UK Middle East amp Africa T +4401786433400 F +44 01786433401

Singapore - Asia Pacific T +65-6777-8211 F +65-6770-8001

USA Toll Free 1-888-FLOW-001 wwwdanielcom

Daniel is a whOlly owned subsidiary of Emerson Electric Co and a division of Emerson Process Management The Daniel logo is a registered trademark of Daniel Industnes tnc The Emerson logo is a trademark and service mark of Emerson Electric Co Brand mark listing are marks of one of the Emerson Process Management family of companies All other marks are property of their respecl ive owners The Daniel UltraSonic Gas Flow Meter including Mark III electronics is covered by US Patents 598330 and 4646 575 and patents pending The contents of this publication are presented for information purposes only and while effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or thel( use or applicability Daniel does not assume responsibility for the selection use or maintenance of any Daniel product Responsibility for proper selection use and maintenance of any Daniel product remains solely wilh the purchaser and end-userAII sales are governed by our terms and conditions which are available upon request We reserve the right to modify or improve the designs or specification of our products at any time without notice

-- -~J ~~--------- EMERSON bull ~ I

copy2004 Daniel Measurement and Control Inc All rights reserved Printed in the USA DAN -GFM-DS-0221-rev0404

reg DAN-3MT-3M-0801 -~I August 2001_-shy

3 SectioQltandProfiler Meter Tubes ~ Pf~6 5 ~~ IrMimiddot~

Instruments You Can Trust Daniel Meter Tubes are more than just fabricated pipe with an orifice fitting They are accurate dependable instruments because of Daniels dedicated approach to quality Extra steps taken during every phase of meter tube design and production separate Daniel Meter Tubes from all the rest

The Daniel 3 section meter tube is available with any style Senior or Junior orifice fitting Simplex plate holder or orifice flanges The assembly contains an inlet spool of the minimum length prescribed by the 143 standard The second section begins with a concentric flange mounted tube bund=1 leetln9 the 2000 API 143 requirements and a W thick spacer plate to ease tube removal for inspection The 04~r end of section 2 conshytains the orifice flange or fitting The third or downstream section follows and contains 2 branchOonnections and is extra long to allow for the addition of extra branch conshynections in the field If desired The standard meter tube has flanged outer ends Other end connections are avaUable on request

Inspectionffesting= Daniel maintains rigid inspection procedures during manufacturing of meter tubes Micrometer and internal surface roughness readings are recorded and supplied with each meter tUbe Customer or third party inspectors are welcome to verify these readings Radiography of welds is another service that is available

Fabrication Fabrication of your instrument Includes attaching the orifice fitting to the meter tube to make an integral primary measuring element For welding operashytions Daniel uses automatic welding machines and rotatshying positioners Highly skilled code qualified welders are employed to tum out highest quality on each job Special internal jigs and fixtures are used to insure smooth Inlet and outlet surfaces without steps or offsets All welds receive expert grinding by experienced craftsshy

men X

cl

-

gt shy

~

-

J ~

Features bull Dowel pin alignment close tolerance maleffemale

flange or knock out dowel pins insure that the bores of sections two and three are matched without offsets

One 1h and one 0 branch connection on the downstream for thermowell or other uses standard

Beveled flanged or reduced ends as well as any available weld fitting can be furnished on the ends of the tubes

Hydrostatically tested after manufacture

Each orifice fitting is tested for tap hole and orifice plate seal integrity after the meter tube has been pressure tested

Material Selection Daniel uses special cold drawn seamless tubing or honed pipe in the fabrication of meter tubes The strict reqUirements for intemal roundshyness and surface finish preclude the use of standard commercial pipe in most cases Daniel maintains a large inventory of this special pipe to rapidly complete your order

LT

EMERSON~ ltocess Management

~~------------------------------------------------------------~------------------------------

Raised Face Weld neck

NA

3M-30RW

3M-60RW High Pressure

3M-90RW 3M-150RW 3M-250RW

DAN-3MT-3M-0801 August 2001

3 Section Meter Tube Catalog Numbers 2-12 with Senior Fitting 10 amp 12 with Junior Fittina

~

Pressure Rating

150

Flange by Weld

(Flangnek)

3M-011

Flange by Flange

(Flanged)

3M-101

Weld by Weld

(Weldnek)

NA

Flange by Weld

(Flangnek)

3M-021

Flange by Flange

(Flanged)

3M-201

Weld by Weld

(Weldnek)

NA

300 3M-013 3M-103 NA 3M-023 3M-203 NA

600 3M-015 3M-105 3M-185 3M-025 3M-205 3M-285

H~h Pressure 3 Section Meter Tubes 900 3M-016 3M-106 3M-186 3M-026 3M-206 3M-286

1500 3M-017 3M-107 3M-187 3M-027 3M-207 3M-287

2500 3M-018 3M-108 3M-188 3M-028 3M-208 3M-288

2middot8 with Simplex 2middot12 with Orifice Flanges Flange byPressure

WeldRating Weld by Weld (Flangnek) (Weldnek)

150 3M-071 NA 3M-073300 NA

600 3M-075 3M-705 High Pressure

3M-7063M-076900 3M-7071500 3M-077 3M-7083M-0782500 -

Two Section Meter Tubes When Usmg Weldnek Flttmgs

Senior and Simplex fittings are also available in 10000 psi rating in some sizes All units are also available with Ring Type Joint (RTJ) flanges on request Sizes larger than 12 available on request

PackingShipping Daniel bolts together all meter A SPECIAL NOTE The use of factory original Daniel tubes when size permits before shipment This saves parts will assure your Senior Junior and Simplex Orifice the user time and field labor costs Fittings are protectshy fittings will stay within original specifications and operate ed by heavy lumber and the tube flanges by special-cut properly protectors

PaintingCoating The Daniel standard paint is a basic enamel type Special coatings such as multi-coat

offshore systems are available on request

3~Section Meter Tube with Tube Bundle

~-----~ U ----~---------~=~~middotmiddotmiddotmiddot~middot t)middotmiddot-middot ~- - -0bull )00)00 1

I~IC--middotmiddotmiddot-middot -----shyshy-bullmiddotV ------- ~

~ - ~-

~

ii~pound bullbullbull ~

Standard lenAths Size un Upstream 0 Downstream V (vane location)

3 7-5 4-0 130 4 9~~9 4-0 130

6 14-8 5-0 t30

102410 60middot middot 130 1~ +1 2tYS Tq 130 JiIf

Note Straightening vanes are not available in 2line size (See Dald Profller DAN-1852middot 2M)

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Daniel meter tubes can be supshyplied in many combinations and configurations Any of the orifice fittings plate holders or orifice flanges can be included in a meter tube Each 3 section standard meter tube is equipped with a flange mounted tube bundle straightener In accordance with April 2000 API 143 and a 1h thick spacer to facilitate tube removal for inspection Downstreams are longer than minimum required to allow for field Installation of additional branch connections If required

To specify a 3 section meter tube use the designation 3M followed by the type orifice holding deVice Ex 4 600 3 section meter tube with flanged ends using a Senior fitting flangneck style is specified as 4-3M-015 The same unit with a weldneck style Simplex is specified as 4middot3M-705 When ordering specify pipe schedule and end configuration Larger size and custom meter tube designs are available on request

The Daniel Profilertrade three section meter tube is availshy lows and contains 2 branch connections Other or addi able with any style Senior or Junior orifice fitting Simplex tiona I connections can be supplied in this section on plate holder or orifice flanges The assembly contains an request These meter tubes are for use in any piping conshyinlet spool of tile minimum length determined during testshy figuration with beta ratios to 67 Downstream sections ing to the API 143 standard The flange union between are extra long to allow for the addition of extra branch the first and second sections contains the ProfilerN and connections in the field if desired The standard meter a Y2 thick spacer plate to facilitate tube removal for tube has beveled outer ends Flanges or other end conshyinspection The outer end of section 2 contains the orishy nections are available on request fice flange or fitting The third or downstream section fol

Meter Tubes Catalog Numbers - 2 WI emor In9 bull Wit un or Itt ng2 1 th S Fitt 10 amp 12 h J i F i

Pressure Rating

Flange by Weld

(F1angnek)

Flange by Flange

(Flanged)

Weld by Weld

(Weldnek)

Flange by Weld

(Flangnek)

Flange by Flange

(Flanged)

Weld by Weld

(WeJdnek) 150 M011 M-101 NA M-021 M-201 NA 300 M-Q13 M-103 NA M023 M-203

NA 600 M-015 M-105 M-t85 M-025 M-205 M-285

2middot8 with Simplex 2middot12 with Orifice Flanges

Pressure Rating

Flange by Weld

weld by Weld

(Weldnek)CFlananekl 150 M-071 NA 300 M-073 NJA 6QfJ M-()75 M-705

Raised Face Weld Neck

NA - -

lM-30RW M-60RW

Two Section Meter Tube When USing Weldnek Fittings

Consult Factory for High Pressure Applications

PROFILERTM Flow Conditioning Plate

The Profiler has been tested and Shown to be in full compliance with the requirementS of API 143 April 2000 The Profiler both removes swirl

the tube bundle Available In flange mounted model only Also available In RTJ style on request

and creates a fully developed flow profile at the orifice Use of this unit allows shortened upstream straight pipe lengths of 17 diameters Beta ratio limit is 67 as with

-~---

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 4: Medidor de Flujo

m ISO 9001 2000 CERTIFIC AOQ

20 de Oetubre del 2004

Partida Cantidad Oeseripelon 02 1 bull Materiales de eonstrueeion del modulo multivariable

Conexiones a proeeso ~NPT con distaneia entre centros de 218 Partes humedas Diafragma de Hasteloy C (para manejo de gas amargo NACE

MR-01-75) Bridas Acero Inoxidable 316 Anillos de las partes humedas De teflon con alma de vidrio Partes no humedas EI fluido de lienado es Aeeite de silicon anilos de Buna N

Incluye

Un kit de montaje de Acero Inoxidable 316 para pedestal de 2 Un manifold de 5vias de Acero Inoxidable 316 de de diametro para una presion

maxima de 10 000 psi (700 Bar) Software de programaeion gratuito (Ambiente Windows) Embalaje apropiado para embarque a destino marino Documentos ineluidos Certificado de materiales Garantia de operaeion Hojas de

datos rellenas Manuales de mantenimiento operacion y eonfiguracion (en ingles) Lista de partes de repuesto Certifieado de pruebas de planta Certifieado de ealidad Protocolo de pruebas y ealibraeion Certifieado de Calibraeion de la planta

Precio Unitario $ 530000 usn +IVA

Terminos comerciales 1 Validez de la oferta 90 dfas 2 Tiempo de entrega 120 dfas 3 Forma de pago 30 dfas presentacion factura 4 Garantfa de caUdad 12 meses de operacion 018 despues del embarque 5 Precios fijos en dolares arnericanos + NA 6 Embalaje adecuado tipo marino 7 LAB su almacen PEP Cd Del Carmen Campeche

1 Atentam nte

Ing Carlos Manuel Ramos Yeh Corporaci6n Constructora Azteca SA de cv

cramosprotectotankcommx Auxiliar de gerencia

Corooracion Constructora Azteca SA de CV I Protectotlnk Diaz Miron 805 Col Centro c P 96400 Coatzacoalcos Ver Tel (01921) 212122021215042126517 Fax (01921) 21 2 2451

e-mail cramosprotectotankcommx sitio web wwwprotectotankcommx

-- - -

- - -

- - -

V -Conereg Preliminary Sizing

Description ~-cone 8 CSS316 Cone S80 ANSI WN CL600 RF

1000 Fa - aPE D67e-06 d 67e-06

Pv

HL I 210 inWC

~ Entered value Table based on one flow condition (P T Z k ) V25 Version 41

Record Start Date 10-18-2004

Print Date 10-20-2004 ~ McOOMEIER L _ _ _ _ _

By Corporacion Constructora Azteca SA de CV

Fluid

Serial Fluid State

End User Job Ref

IndustryModel

Tag I Gas Combustible r-

f--shy

VW08FF 16N-BAZ

NATURAL GAS 174mw

GAS

CPTG ATASTA

PEP

Note r-085

I kgcm2Gr30 degc

2444 Ibft3

1135e-02 cP -

p

G 06008

Z 09172

Y 09918 c-- - - shy

k I 1302

8573 Cp

Mw 17400

14 696 psi -

OF60000

I 09979 I I 14696 psiPbaro

Pc I 66720 psi

of-11657Tc

----------------------------------------------------------------~

q max Flowrate 50000000 SCFD

6977e+06

34 22 fps

28208 inWC

01110 inWC

7636 in

6820 in

04498

50

McCrometer Cal

Third Party Cal Re max Reynolds

Dye Pen Exam V max Velocity

Hydro Test ilP max Dp

ilP min Dp X-Ray Exam

D Meter 10 Mag Part

d Cone OD PMI

p Beta Ratio CMTR Copies

Turn Down Application Eng

I--- shy

CMRY

Velocity Gas Exp ilP Flowrate

Re fps Y inWC SCFD

1 6977e+06 3422 09918 2821 50000e+07

2 6217e+06 3049 09935 2232 44556e+07

3 5458e+06 2676 09950 1715 39111e+07

4 4698e+06 2304 09963 1267 33667e+07

5 3938e+06 1931 09974 8885 28222e+07

6 3178e+06 1559 09983 5777 22778e+07

7 241ge+06 1186 09990 3341 17333e+07

8 165ge+06 8136 09995 1570 1188ge+07

9 8993e+05 4410 09999 4610 64444e+06

10 1395e+05 06843 1000 01110 10000e+06

File Gas Combustible ATASTAv25

yeoNE reg CONFIGURATION SHEET

PRECISION TUBE SERIESMODELVW (H)

ANSI 8165 Weld Neck Raised Face Flanges - Class 600 or 900

DESCRIPIION AND GENERAL PERFORMANCE SPECIFICATIONS The V -Conereg flowmeter is a patented differential pressure type flow measurement device A cone is positioned in the center of the pipe to increase the velocity of the flowing fluid and create a differential pressure This pressure difference can be measured and used to accurately interpret flowrate Two taps are provided on every V -Cone to allow sensing of the high and low pressures A typical V-Cone application can follow these general performance specifications bull Accuracy up to plusmn05 of rate Model VW Bulletins

ANSI 8165 Weld Neck RF Flanges 24509-35 Class 150 or 300

bull Repeatability plusmnO J bull Turndown 10 1 24509-36 Class 600 or 900 bull Standard Betas 045 through 085 24509-37 Class 125 or 250 bull Headloss Percentage of differential pressure produced varies with beta ratio bull Installation Typically 0-3 diameters upstream and 0-1 diameters downstream Each V -Cone is sized for the intended a Ii cation S ecific erformance ratin s must be obtained throu

MODEL VW(H) DIMENSIONS

H L 2 1 8 (Note 2) B1- ~WE-D DC

~ I -rr --- - T - III

Lk-l - -- -- c-ttt- -- - -- -- - -- -

- - --- --- ---

I

--------------A------------~-t I A lor to 1 1lor to 24

DIMENSION TABLE

I

Size ANSI B165 Class 600 ANSI B165 Class 900 Stainless Carbon

0 E (Note 2) A (Note 1) B A(Note 2) B C (Note 2) C (Note 2)

inch inch mm inch mm inch mm inch mm inch mm inch mm inch mm NPT

y 1225 3112 563 1430 1288 3272 594 1509 0622 158 - - 084 213 Y Y 1263 3208 582 1478 1363 346 2 632 1605 0824 209 - - 105 267 Y 1 1300 3302 601 1527 1388 3526 644 1636 1049 26_64 gtshy - - 1315 334 Y 1Y 1550 3937 576 1463 1650 419 1 626 1590 1645 4178 - - 19 483 Y 2 1763 4478 631 1603 1988 5050 744 1890 2104 5344 - - 2375 603 )I

2)1 1800 4572 650 1651 2000 5080 750 1905 2504 6360 - - 2875 730 Y

3 2025 5144 663 1684 2175 5525 738 1875 3104 7884 - - 35 889 )I

4 2375 6033 788 2002 24 75 6287 838 2129 4090 1038 - - 45 114 Y

6 3100 7874 875 2223 3275 8319 963 2446 6065 1541 6065 1541 6625 168 Y

8 3600 9144 1001 254 3 3825 971 _6 1113 2827 7981 2027 7981 2027 8625 219 )I

10 3950 1003 1076 2733 4200 1067 1201 3051 1002 2545 1002 254 5 1075 273 Y

12 4175 1060 1113 2827 452 5 1149 1288 327 2 1200 3048 1194 3033 1275 323 Y

14 4225 1073 1213 3081 4600 1168 1400 3556 1325 336 6 1313 3335 14 355 Y

16 4325 1099 1263 3208 4625 1175 1413 3589 1525 3874 1500 3810 16 406 Y

18 4575 1162 1288 3272 4925 1251 1463 371 6 1725 438 2 1725 4382 18 457 Y

20 5025 )11276 11 1313 3335 5475 1391 1538 3907 1925 4890 1925 4890 20 508 Y

24 6325 1607 1763 4478 7025 1784 2113 536 7 2325 5906 2325 5906 24 609 Y 1 Overall length (A) tolerance vanes With line size jYto 1 plusmn18 (plusmn4mm) 1 jYto 10 plusmn316 (plusmn6mm) 12 to 24 plusmn14 (

2 Typical values shown

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-68111 Fax (909) 652-3078$ MQ[)MEIER Web Site httpWlNwmccrometercom e-mail infomccrometercom

Lit24509-36 Rev 146-00 copy2000 by McCrometcr Inc Printed in USA

I bull

CONFIGURAIiON SHEET MODEL NUMBER CONFIGURATION VW(H)

Pipe Size Materialsj Schedule FittingsEnd Connections

VW Q A 10OA S304V2 JLj CL 600 RF WN LtJ NPT

OB L S304L B 20 17 CL 900 RF WN S Socket 01 1 A S316L C Bored

Scvcmllypcs of ICS Tube amp Flanges 0 StdOC 1V2 ~ fittings aV01ilablc

2 40 00

S304 Cone Support amp Couplings E02 Epoxy Coated Blue (excluding cone) F 80

03 2V2 3 r-u CS Tube amp Flanges J 100

04 4 S304 Cone Support amp Couplings 120K jOther materials can include6 Coating Painting Per Customer Req 14006 L

-shy HASTELLOY C-276 S321H8 G 160 DUPLEX 2205 INCONEL 625

08 10 XXS

CHROMEMOLY P22PII 10 H

10S MONEL K400K500

12 M12 14 P XS

CARBON STEELS 14

16 -- shy

A350 A333 AP15L A 106B 16

18 20 18

20 24~

Example VW10AE16N V-Cone 10 inch line size S316L schedule 40 pipe ANSI CL 600 RF WN flanges V2NPT fittings

Type

STANDARD PIPE SCHEDUIpoundS Stainless Steel Carbon Steel

Size Std Size Std to 4 C

6 to 10 E 12 and up 0

6 to 16 18 and up

E 0

Pipe up to 8 utilizes seamless pipe Above 8 is welded pipe

ABBREVIATIONS ASME American Society of Mechanical Engineers NPT National pipe taper SS Stainless steel RF Raised Face CS Carbon steel WN Weld Neck

Technical questions can be answered through a local representative or through our application engineers

REPRESENTED BY

MANUFACTURING STANDARDS McCrometers welders and welding procedures are qualified in accordance with ASME Section IX All meters are visually inspected for weld defects Specific customer requirements can be complied with upon request

The welding can be in accordance with

bull ASME Section VIII

bull ASME B311

bull ASMEB313

Non-destmctive testing can include

bull Hydrostatic Pressure Testing

bull Penetrant Examination

bull Radiographic Examination

bull Positive Material Inspection

bull Magnetic Particle Examination

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-6811 Fax (909) 652-3078 Web Site httpwwwmccromelercom e-mail infomccrometercom

Lit24509-36 Rev 146-00 copy 2000 by McCrometer IncPrinted in USA

~----------------------~---------------------------------------------------------------------------

V -Cone Installation Guide Upstream and Downstream Minimum Straight Pipe Run Requirements

For Liquid Metering and Gases at a Reynolds Number (Re) Value Less Than or Equal To 200000

For fl greater than or equal to 065 add ID

Obstruction DownSize Range Up Stream Stream

I Elbow OD

2 Elbows

OD

OD OD

Tees OD OD Not Preferred ValveAll Sizes Butterfly Valve (control valve) DownstreamPosition

3D 3D

Butterfly Valve (shutoff valve) 3D OD

Full port Ballvalve (shutoff) OD OD

Heat Exchanger (Depends on Type) OD OD

Expander (067D to D) over a length ID ID of 2SD

Reducer (3D to D) over a length of ID ID 3SD

Note The meter and adjoining pipe should have equal IDs

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-6811 Fax (909) 652-3078 ~ MCOOMEIER Web Site http wwwmccrometercom e-mail infomccrometercom

Lit24S09-21 Rev 10102-04 copy2004 by McCrometer InclPrinted in USA

Product Data Sheet DAN-GFM-DS -21-rev0404 ( )

April2004 SeniorSonic with Mark TM Electronics

- SeniorSonic The Daniel SeniorSonic Gas Flow Meter with Mark IWM Electronics saves you time and money Lost and unaccounted for gas is reduced by exceptional low and high flow accuracy and linearity throughout the calibrated flow range Time is saved by a best-in-class audit trail Mark III Electronics can pinpoint alarms events and configuration changes in a matter of seconds Best of all operating the Daniel SeniorSonic gas flow meter is easy with the Windowsreg based Daniel Customer User Interface (CUI) software

Features middot Excellent long-term performance

Velocity Range Most sizes are rated to performa at 100 fps middot Full electronic audit trail (exceeds API 211) Over-range of up to 125 fps and in some cases beyond 125 middot Exceptional low and high flow performance

middot Bi-directional multi-point calibration coefficients fps in emergencymiddot situations and without transducer failure

middot Rangeability exceeds 50 1 with calibration Availability is limited by line size and ANSI rating Visit middot ANSI 30060090015002500 versions wwwdanielcomseniorsonic for additional information middot Extractable transducers (For all sizes) middot Minimum upstream piping requirements Meter specifications

Gas temperature -4 to +212deg F (-20 to +100deg C) Easy to learn and use CUI software features Operating pressure range 150 - 3750 psig middot Comprehensive monitor screen (1030 - 25855 kPa) Consult factory for lower and middot Field start-up wizard higher pressure applications middot Calibration wizards (analog and frequency) Flanges RF for 3001500 RTJ for 6002500 middot Flow calibration configuration wizard middot Audit 1 alarm 1history retrieval Power DC version - 1224 (11-36) VDC 6 watts maximum middot Digital waveform viewing middot Maintenance log summary in ExcelI Environmental middot Built-in AGA 10 SOS calculator Operating temperature -40 to +149deg F (-40 to +65deg C) middot Automatic file naming Operating relative humidity up to 95 non-condensing middot Trending of maintenance logs Storage temperature -40 to +185 0 F (-40 to +85 0 C) middot Configuration comparison with exception summary middot Remote dial-up support and Ethernet support Typical Applications middot Unlimited meter directory support middot Custody transfer

middot Power plants Specifications middot Large industrial users

Electronic unit middot City gates Communication protocol Modbus RTUASCII amp TCPIIP middot Production Two serial RS-232485 ports and Ethernet middot Underground storage sites Communication speed Up to 115 KBPS middot Offshore Frequency outputs Four Frequency range 0-10005000 Hz Safety classifications Digital output Selectable (up to four for data valid or flow UL listed for use in Class I Division 1 Group D hazardous

direction) locations in both the US and Canada (UL E152246) Calculation update time Configurable for 14 and 1 second CE marked to ATEX directive (949EC ) (pending)

Certified to Eex d ia liB T4 to standards EN 50014 EN 50018 Accuracy and EN 50020 (pending) Flow calibrated accuracy plusmn 01 (Relative to lab) Absolute accuracy Including lab uncertainty about 03 Repeatability plusmn 02 of reading for Ot to Omax

-- - tI II~ EMERSON ~-----

wwwdanielcom

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Recommended Ma~jum Flow Velocity Meter Size J Meter Size Metric Max Inches Max ftI~ m tris

4 100 100 30 6 100 150 30 8 100 200 30

10 80 250 24 12 80 300 24 16 85 400 26 20 85 500 26 24 85 600 26 30 70 750 21 36 70 900 21

Dimensions These measurements are meant only as an aid in the design of metering systems Consult Daniel engineering drawings prior to construction

Typical 600 ANSI Meter with 45 Degree-Angled Transducers Overall End- Flange Approximate Overall End- Flange Approximate

Meter Size To-End Diameter Weight To-End Diameter Weight (Inches) (Inches) (Inches) (Pounds) (Millimeters) (Millimeters) (Kilograms)

4 2900 1075 370 737 273 168 6 2950 1400 460 749 356 209

8 3150 1650 650 800 419 295 10 3400 2000 885 864 508 402 12 3544 2200 1075 900 559 489 16 4400 2700 1955 1118 686 889 18 4531 2925 2800 11sect1 743 1273 20 5062 3200 30Z5 12amp6 84~ 1398

0 4 5862 3700 404~ 1489 940 1839 30 6700 4450 4925 1702 1130 2239 36 7350 5175 6425 1867 1314 2920

()l p l ( C flO

bull I iY0

e

Page 2

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 60 F and gas composition These values are intended to be a guide in Contact Daniel engineering for a specific application

_ Flow Rates (JIISCFHl Basea Upon 100 ftls PSIG 4 6 8 10 12 16 20 24 30 36 100 247 561 971 1532 2174 3432 5398 7807 12607 18154 200 468 1065 1845 2908 4127 6515 10248 14822 23935 34467 300 696 1584 2743 4325 6137 9690 15240 22043 35596 51258 400 931 2118 3668 5782 8206 12955 20377 29472 47593 68534 500 2667 4619 7282 10334 16315 25661 37114 59934 86305 600 1421 3232 5597 8823 12522 19770 31095 44973 72626 104582 700 1676 3813 6602 10409 14772 23322 36682 53055 85677 123374 800 1938 4409 7635 12036 17082 26968 42417 61349 99070 142661 900 2207 5021 8694 13706 19452 30710 48302 69861 112816 162455 1000 2482 5646 9777 15414 21875 34536 54320 78565 126872 182696 1100 2763 6286 10885 17161 24355 38451 60478 87471 141254 203405 1200 3050 6939 12015 18943 26883 42443 66756 96551 155917 224521 1300 3341 7602 13164 20753 29453 46500 73137 105781 170822 245983 1400 3637 8274 14327 22587 32055 50608 79599 115127 185915 267718 1500 3935 8953 15504 24442 34688 54765 86137 124583 201184 289706 1600 4235 9635 16685 26305 37331 58938 92700 134076 216515 311781 1700 4536 10321 17871 28175 39986 63128 99291 143608 231908 333948 1800 4836 11002 19052 30036 42627 67298 105850 153094 247227 356006 1900 5134 11681 20226 31888 45255 71448 112376 162534 262471 377958 2000 5429 12350 21386 33716 47849 75543 118818 171851 277516 399623

Flow Rates (MIfIISCFfJ) Based Upon 100 ffls PSIG 4 6 8 10 12 16 20 24 30 36 100 59 135 233 368 522 824 1295 1874 3026 4357 200 113 256 443 698 990 1564 2459 3557 5744 8272 300 168 380 658 1038 1473 2326 3658 5290 8543 1230 400 224 508 880 1388 1969 3109 4890 7073 1142 1645 600 282 640 110~ 1748 2480 3916 6159 8907 1438 2071 600 342 776 1343 2118 3005 4745 7463 1079 1743 2510 700 403 915 1685 2498 3545 5597 8804 1273 2066 2961 800 466 1058 1832 2889 4100 6472 1018 1472 2378 3424 900 531 1205 2087 3289 4668 7370 1159 1677 2708 3899

1000 597 1355 2346 3699 5250 8289 1304 1886 3045 4385 1100 665 1509 2612 4119 5845 9228 1451 2099 3390 4882 1200 734 1665 2884 4546 6452 1019 1602 2317 3742 5389 1300 804 1824 3159 4981 7069 1116 1755 2539 4100 5904 1400 875 1986 3438 5421 7693 1215 1910 2763 4462 6425 1500 947 2149 3721 5866 8325 1314 2067 2990 4828 6953 1600 1019 2313 4004 6313 8960 1415 2225 3218 5196 7483 1700 1091 2477 4289 6762 9597 1515 2383 3447 5566middot 8015 1800 1164 2641 4572 7209 1023 1615 2540 3674 5933 8544 1900 1235 2803 4854 7653 1086 1715 2697 3901 6299 9071 2000 1306 2964 5133 8092 1148 1813 2852 4124 6660 9591

Calculating meter capacity To calculate a volume rate for a given velocity multiply the capacity in this table by the desired at the pressure and divide the answer by 100 Example Determine the hourly flow rate al 70 fps for an 8 inch meter operating at 800 psig Volume =7635 MSCFH Velocity 70 Answer = 763570100 = 5344 MSCFH

Pa~e 3

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 20 F and gas composition These values are intended to be a guide In Contact Daniel nee ring for a application

Flow RateS (IASOFH) Based UppJ1 30 mls Schedule 40) kPag 4 6 8 10 12 16 20 24 30 36 1000 967 2201 3811 6007 8527 1346 2117 3062 4945 7121 1500 1422 3234 5600 8827 1253 1978 3111 4500 7267 1046 2000 1885 4289 7428 1171 1662 2624 4127 5969 9639 1388 2500 2359 5367 9294 1465 2079 3283 5164 7469 1206 1737 3000 2843 6468 1120 1765 2506 3956 6223 9000 1453 2093 3500 3337 7592 1315 2072 2941 4644 7304 1056 1706 2457 4000 3841 8739 1513 2385 3386 5346 8408 1216 1964 2828 4500 4356 9910 171S 2705 3840 6062 9535 1379 2227 3207 5000 4881 1111 1923 3031 4303 6793 1068 1546 2495 3593 5500 5417 1232 2134 3364 4774 7538 1186 1715 2769 3987 6000 5962 1 3702 5255 8297 1305 1887 3048 4389 6500 6517 1483 2568 4047 5745 9070 1427 2063 3332 4798 7000 7082 1611 2790 4398 6243 9856 1550 2242 3621 5214 7500 7656 1742 3016 4754 6748 1065 1676 2424 3914 5636 8000 8238 1874 3246 5116 7262 1146 1803 2608 4212 6065 8500 8828 2009 3478 5482 7782 1229 1932 2795 4513 6499 9000 9425 2144 3713 5853 8308 1312 2063 2984 4818 6939 9500 10028 2281 3951 6227 8839 1396 2195 3175 5127 7382

10000 10636 2420 4190 6604 9375 1480 2328 3367 5437 7830

Flow Rates (IANSOND) Based Upon 30 mls (Scnedule 40) PSIG 4 6 8 10 12 16 20 24 30 36 1000 0232 0528 0915 1442 2046 3231 5082 7350 11869 17091 1500 0341 0776 1344 2119 3007 4748 7468 10801 17441 25116 2000 0453 1029 1783 2810 3989 6297 9904 14325 23133 33311 2500 0566 1288 2231 3516 4991 7879 12393 17924 28946 41682 3000 0682 1552 2688 4237 6014 9495 14935 21600 34882 50230 3500 0801 1821 3155 4973 7059 11145 17530 25354 40943 58958 4000 0922 2097 3632 5725 8126 12830 20179 29186 47131 67869 4500 1045 2378 4119 6492 9215 14549 22883 33097 53447 76963 5000 1171 2664 4615 7275 10326 16302 25641 37086 59889 86240 5500 1300 2957 5121 8072 11459 18091 28454 41154 66458 95699 6000 1431 3254 5637 8885 19912 31319 45298 73150 105336 6500 1564 3557 6162 9713 13787 21767 34236 49517 79964 115148 7000 1700 3866 6696 10555 14982 23653 37203 53808 86893 125126 7500 1837 4179 7239 11410 16196 25570 40218 58168 93934 135265 8000 1977 4497 7789 12278 17428 27515 43277 62592 101078 145553 8500 2119 4819 8347 13157 18676 29485 46376 67075 108318 155978 9000 2262 51 8912 14047 19939 31479 71611 115642 166524 9500 2407 5474 9482 14945 21214 33492 52679 76191 123038 177175

10000 2553 5805 10056 15851 22500 35522 55871 80808 130494 187911

Calculating meter capacity To calculate a volume rate for a given velocity the capacity this table by the desired velocity at the operating pressure and divide the answer 100 Determine the hourly flow rate at 30 mps for an 8 inch meter at 4500 Volume 1716 Velocity 10 Answer 17161030 5719 MSCMH

Product Oata Sheet DAN-GFM-DS-21-rev0404 April 2004

The drawings below represent recommended piping lengths for various flow conditioners when installed with the Daniel SeniorSonic flowmeter If shorter lengths are used there may be an increase in flow measurement uncertainty

Piping Recommendation For SeniorSonic With No Flow Conditioner

1~~--------------------200 -----------------------~

Q----I__------shy~

J ~~f --M-I-middotn-im-~-~-p-iP-i-n-g-R-e-c-o-m-m-e-n-a-a-tl-o-n-F-o-r-S-en-I-o-r-S-o-n-ic-W-it-h-D-a-n-ie-l-p-r-O-fi-le-r-o-r-C-p-~-5-0-E~-F--o-w-c-o-n-d-itl-io-n-e-r--

1 00 middot -2 o~o ~1gt

[ _____ ---Al11~ ----- =ul [II I

I 0 0 a It Minimum Piping Recommendation for Bimiddotdirectional SeniorSonic

with Daniel Profiler or CPA 50E Flow Conditioner

~------- 100 ------t ~------- 100 ----~ - 50---shy

3middot 50

-- 50 ---shy

3middot 50

~ -

A WARNING Do not operate this instrument in excess of the specifications listed Failure to heed this warning could result in serious injury andor damage to the equipment

Page 5

---- - --- _ --- ----------------- -------------------------shy

--iI

-------~~--------1

----~----------------I _____________________I

----~------~----__i _____bullmiddot________ ----__i

____________shy____~__i

____________________---i __________________

_________shy__________~~

~ I ~

I

~

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

8

10

12

16

20

24

30

36 r

ANSI Class 300 600--~------------------------i

900__________----__------__------i 1500

-------------------------------~ Flange Raised Face (RF) _________________-_------j

Ring Type Joint (RTJ)___---------__bull-_____Imiddot

Materials Standard ~----~~--~----~--------~~ Stainless Steel

DJplex --~--------------------------~----~ _________________________--____~__

Device Type

Electronics

Transducers

Meter Size (Inches)

Daniel Ultrasonic Model Number Selections ES-21055 RevW

SeniorSonic (4-Path) ---------------1 JuniorSonic (1~Path) ------------1 JuniorSonic (2-Path) ______________

Mark II UL 24VDC 4-20rlA 3NPT

Mark UL 24VDC 1middot5VDC 3NPT ---------------------1 Mark CENaEC 24V DC 4-20mA M20 --------------_--__1

Mark IICB-JELEC24VDC1-SVDCM20

Mark II ClNELEc 24VDC 4-20mA M20 Rerrote

Mark II CENELEC 24VDC 1-5VDCM20 Rerrote

MarkU UL 24VOC4-20mA 3NPT Rerrote_

Mark II U~ 24VDC l-SVPG 3NPT Rerrote

Mark IIIUL 34 NPT

Mark III UL 34NPT Rerrote

TmiddotSlo T-12

4

middot 6

Page 6

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Systems Daniel Measurement and Control is the industry leader in designing constructing and commissioning of complex oil and gas metering systems to exacting standards

This global organization offers decades of petroleum fiscal flow measurement application experience Customers rely confidently on Daniels Systems Group international fabrication facilities customized engineering and its successes in field-testing and support From the simplest single-stream skid to complex on-site installations Daniel Systems delivers both natural gas and liquid petroleum tumkey applications Daniel Systems designs constructs and commissions the metering project blending up-toshythe-minute technology with decades of understanding what customers need and expect

Components of a Daniel Systems installation typically include meters valves provers flow-control instruments instrumentation and read-out equipment and process management components

Computer software and hardware are integrated with the measurement system Standard calculation methods include AGA3 (now API-MPMS-143) ISO 5167 AGA578 AGA9 and the API Manual for Petroleum Measurement Standards

Daniel DMSS-2000 Supervisory Control Systems utilize a sophisticated Graphical User Interface database server and a dedicated PLC for the metering skidMOV interface Redundancy is often used for custody transfer systems andor when system integrity is essential

A dedicated Project Manager and Project Team are assigned to each measurement system project This team is responsible for overall system design and project construction from start to finish A separate internal QAQC group reviews all design detailS inside and outside fabrication assembly and system testing

Whether it is a pipeline offshore production facility or a loading facility for ocean-going tankers the Daniel Systems group is a proven single-source solution for customers throughout the world

Page 7

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Daniel Measurement Services Daniel Measurement Services takes pride in being there after needs arise with the right solution for customers with gas and liquid fiscal flow measurement applications

Around the clock and around the world Daniel Measurement Services has experienced highly qualified people prepared to help customers who need assistance with the following

middot Start-up and commissioning middot Preventive maintenance middot Product repair I upgrades middot Project management and integration middot Meter Tube inspection and recertification middot Remote diagnostics middot Warranty Plus middot Technical training

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880

Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337

Stirling Scotland - UK Middle East amp Africa T +4401786433400 F +44 01786433401

Singapore - Asia Pacific T +65-6777-8211 F +65-6770-8001

USA Toll Free 1-888-FLOW-001 wwwdanielcom

Daniel is a whOlly owned subsidiary of Emerson Electric Co and a division of Emerson Process Management The Daniel logo is a registered trademark of Daniel Industnes tnc The Emerson logo is a trademark and service mark of Emerson Electric Co Brand mark listing are marks of one of the Emerson Process Management family of companies All other marks are property of their respecl ive owners The Daniel UltraSonic Gas Flow Meter including Mark III electronics is covered by US Patents 598330 and 4646 575 and patents pending The contents of this publication are presented for information purposes only and while effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or thel( use or applicability Daniel does not assume responsibility for the selection use or maintenance of any Daniel product Responsibility for proper selection use and maintenance of any Daniel product remains solely wilh the purchaser and end-userAII sales are governed by our terms and conditions which are available upon request We reserve the right to modify or improve the designs or specification of our products at any time without notice

-- -~J ~~--------- EMERSON bull ~ I

copy2004 Daniel Measurement and Control Inc All rights reserved Printed in the USA DAN -GFM-DS-0221-rev0404

reg DAN-3MT-3M-0801 -~I August 2001_-shy

3 SectioQltandProfiler Meter Tubes ~ Pf~6 5 ~~ IrMimiddot~

Instruments You Can Trust Daniel Meter Tubes are more than just fabricated pipe with an orifice fitting They are accurate dependable instruments because of Daniels dedicated approach to quality Extra steps taken during every phase of meter tube design and production separate Daniel Meter Tubes from all the rest

The Daniel 3 section meter tube is available with any style Senior or Junior orifice fitting Simplex plate holder or orifice flanges The assembly contains an inlet spool of the minimum length prescribed by the 143 standard The second section begins with a concentric flange mounted tube bund=1 leetln9 the 2000 API 143 requirements and a W thick spacer plate to ease tube removal for inspection The 04~r end of section 2 conshytains the orifice flange or fitting The third or downstream section follows and contains 2 branchOonnections and is extra long to allow for the addition of extra branch conshynections in the field If desired The standard meter tube has flanged outer ends Other end connections are avaUable on request

Inspectionffesting= Daniel maintains rigid inspection procedures during manufacturing of meter tubes Micrometer and internal surface roughness readings are recorded and supplied with each meter tUbe Customer or third party inspectors are welcome to verify these readings Radiography of welds is another service that is available

Fabrication Fabrication of your instrument Includes attaching the orifice fitting to the meter tube to make an integral primary measuring element For welding operashytions Daniel uses automatic welding machines and rotatshying positioners Highly skilled code qualified welders are employed to tum out highest quality on each job Special internal jigs and fixtures are used to insure smooth Inlet and outlet surfaces without steps or offsets All welds receive expert grinding by experienced craftsshy

men X

cl

-

gt shy

~

-

J ~

Features bull Dowel pin alignment close tolerance maleffemale

flange or knock out dowel pins insure that the bores of sections two and three are matched without offsets

One 1h and one 0 branch connection on the downstream for thermowell or other uses standard

Beveled flanged or reduced ends as well as any available weld fitting can be furnished on the ends of the tubes

Hydrostatically tested after manufacture

Each orifice fitting is tested for tap hole and orifice plate seal integrity after the meter tube has been pressure tested

Material Selection Daniel uses special cold drawn seamless tubing or honed pipe in the fabrication of meter tubes The strict reqUirements for intemal roundshyness and surface finish preclude the use of standard commercial pipe in most cases Daniel maintains a large inventory of this special pipe to rapidly complete your order

LT

EMERSON~ ltocess Management

~~------------------------------------------------------------~------------------------------

Raised Face Weld neck

NA

3M-30RW

3M-60RW High Pressure

3M-90RW 3M-150RW 3M-250RW

DAN-3MT-3M-0801 August 2001

3 Section Meter Tube Catalog Numbers 2-12 with Senior Fitting 10 amp 12 with Junior Fittina

~

Pressure Rating

150

Flange by Weld

(Flangnek)

3M-011

Flange by Flange

(Flanged)

3M-101

Weld by Weld

(Weldnek)

NA

Flange by Weld

(Flangnek)

3M-021

Flange by Flange

(Flanged)

3M-201

Weld by Weld

(Weldnek)

NA

300 3M-013 3M-103 NA 3M-023 3M-203 NA

600 3M-015 3M-105 3M-185 3M-025 3M-205 3M-285

H~h Pressure 3 Section Meter Tubes 900 3M-016 3M-106 3M-186 3M-026 3M-206 3M-286

1500 3M-017 3M-107 3M-187 3M-027 3M-207 3M-287

2500 3M-018 3M-108 3M-188 3M-028 3M-208 3M-288

2middot8 with Simplex 2middot12 with Orifice Flanges Flange byPressure

WeldRating Weld by Weld (Flangnek) (Weldnek)

150 3M-071 NA 3M-073300 NA

600 3M-075 3M-705 High Pressure

3M-7063M-076900 3M-7071500 3M-077 3M-7083M-0782500 -

Two Section Meter Tubes When Usmg Weldnek Flttmgs

Senior and Simplex fittings are also available in 10000 psi rating in some sizes All units are also available with Ring Type Joint (RTJ) flanges on request Sizes larger than 12 available on request

PackingShipping Daniel bolts together all meter A SPECIAL NOTE The use of factory original Daniel tubes when size permits before shipment This saves parts will assure your Senior Junior and Simplex Orifice the user time and field labor costs Fittings are protectshy fittings will stay within original specifications and operate ed by heavy lumber and the tube flanges by special-cut properly protectors

PaintingCoating The Daniel standard paint is a basic enamel type Special coatings such as multi-coat

offshore systems are available on request

3~Section Meter Tube with Tube Bundle

~-----~ U ----~---------~=~~middotmiddotmiddotmiddot~middot t)middotmiddot-middot ~- - -0bull )00)00 1

I~IC--middotmiddotmiddot-middot -----shyshy-bullmiddotV ------- ~

~ - ~-

~

ii~pound bullbullbull ~

Standard lenAths Size un Upstream 0 Downstream V (vane location)

3 7-5 4-0 130 4 9~~9 4-0 130

6 14-8 5-0 t30

102410 60middot middot 130 1~ +1 2tYS Tq 130 JiIf

Note Straightening vanes are not available in 2line size (See Dald Profller DAN-1852middot 2M)

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Daniel meter tubes can be supshyplied in many combinations and configurations Any of the orifice fittings plate holders or orifice flanges can be included in a meter tube Each 3 section standard meter tube is equipped with a flange mounted tube bundle straightener In accordance with April 2000 API 143 and a 1h thick spacer to facilitate tube removal for inspection Downstreams are longer than minimum required to allow for field Installation of additional branch connections If required

To specify a 3 section meter tube use the designation 3M followed by the type orifice holding deVice Ex 4 600 3 section meter tube with flanged ends using a Senior fitting flangneck style is specified as 4-3M-015 The same unit with a weldneck style Simplex is specified as 4middot3M-705 When ordering specify pipe schedule and end configuration Larger size and custom meter tube designs are available on request

The Daniel Profilertrade three section meter tube is availshy lows and contains 2 branch connections Other or addi able with any style Senior or Junior orifice fitting Simplex tiona I connections can be supplied in this section on plate holder or orifice flanges The assembly contains an request These meter tubes are for use in any piping conshyinlet spool of tile minimum length determined during testshy figuration with beta ratios to 67 Downstream sections ing to the API 143 standard The flange union between are extra long to allow for the addition of extra branch the first and second sections contains the ProfilerN and connections in the field if desired The standard meter a Y2 thick spacer plate to facilitate tube removal for tube has beveled outer ends Flanges or other end conshyinspection The outer end of section 2 contains the orishy nections are available on request fice flange or fitting The third or downstream section fol

Meter Tubes Catalog Numbers - 2 WI emor In9 bull Wit un or Itt ng2 1 th S Fitt 10 amp 12 h J i F i

Pressure Rating

Flange by Weld

(F1angnek)

Flange by Flange

(Flanged)

Weld by Weld

(Weldnek)

Flange by Weld

(Flangnek)

Flange by Flange

(Flanged)

Weld by Weld

(WeJdnek) 150 M011 M-101 NA M-021 M-201 NA 300 M-Q13 M-103 NA M023 M-203

NA 600 M-015 M-105 M-t85 M-025 M-205 M-285

2middot8 with Simplex 2middot12 with Orifice Flanges

Pressure Rating

Flange by Weld

weld by Weld

(Weldnek)CFlananekl 150 M-071 NA 300 M-073 NJA 6QfJ M-()75 M-705

Raised Face Weld Neck

NA - -

lM-30RW M-60RW

Two Section Meter Tube When USing Weldnek Fittings

Consult Factory for High Pressure Applications

PROFILERTM Flow Conditioning Plate

The Profiler has been tested and Shown to be in full compliance with the requirementS of API 143 April 2000 The Profiler both removes swirl

the tube bundle Available In flange mounted model only Also available In RTJ style on request

and creates a fully developed flow profile at the orifice Use of this unit allows shortened upstream straight pipe lengths of 17 diameters Beta ratio limit is 67 as with

-~---

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 5: Medidor de Flujo

-- - -

- - -

- - -

V -Conereg Preliminary Sizing

Description ~-cone 8 CSS316 Cone S80 ANSI WN CL600 RF

1000 Fa - aPE D67e-06 d 67e-06

Pv

HL I 210 inWC

~ Entered value Table based on one flow condition (P T Z k ) V25 Version 41

Record Start Date 10-18-2004

Print Date 10-20-2004 ~ McOOMEIER L _ _ _ _ _

By Corporacion Constructora Azteca SA de CV

Fluid

Serial Fluid State

End User Job Ref

IndustryModel

Tag I Gas Combustible r-

f--shy

VW08FF 16N-BAZ

NATURAL GAS 174mw

GAS

CPTG ATASTA

PEP

Note r-085

I kgcm2Gr30 degc

2444 Ibft3

1135e-02 cP -

p

G 06008

Z 09172

Y 09918 c-- - - shy

k I 1302

8573 Cp

Mw 17400

14 696 psi -

OF60000

I 09979 I I 14696 psiPbaro

Pc I 66720 psi

of-11657Tc

----------------------------------------------------------------~

q max Flowrate 50000000 SCFD

6977e+06

34 22 fps

28208 inWC

01110 inWC

7636 in

6820 in

04498

50

McCrometer Cal

Third Party Cal Re max Reynolds

Dye Pen Exam V max Velocity

Hydro Test ilP max Dp

ilP min Dp X-Ray Exam

D Meter 10 Mag Part

d Cone OD PMI

p Beta Ratio CMTR Copies

Turn Down Application Eng

I--- shy

CMRY

Velocity Gas Exp ilP Flowrate

Re fps Y inWC SCFD

1 6977e+06 3422 09918 2821 50000e+07

2 6217e+06 3049 09935 2232 44556e+07

3 5458e+06 2676 09950 1715 39111e+07

4 4698e+06 2304 09963 1267 33667e+07

5 3938e+06 1931 09974 8885 28222e+07

6 3178e+06 1559 09983 5777 22778e+07

7 241ge+06 1186 09990 3341 17333e+07

8 165ge+06 8136 09995 1570 1188ge+07

9 8993e+05 4410 09999 4610 64444e+06

10 1395e+05 06843 1000 01110 10000e+06

File Gas Combustible ATASTAv25

yeoNE reg CONFIGURATION SHEET

PRECISION TUBE SERIESMODELVW (H)

ANSI 8165 Weld Neck Raised Face Flanges - Class 600 or 900

DESCRIPIION AND GENERAL PERFORMANCE SPECIFICATIONS The V -Conereg flowmeter is a patented differential pressure type flow measurement device A cone is positioned in the center of the pipe to increase the velocity of the flowing fluid and create a differential pressure This pressure difference can be measured and used to accurately interpret flowrate Two taps are provided on every V -Cone to allow sensing of the high and low pressures A typical V-Cone application can follow these general performance specifications bull Accuracy up to plusmn05 of rate Model VW Bulletins

ANSI 8165 Weld Neck RF Flanges 24509-35 Class 150 or 300

bull Repeatability plusmnO J bull Turndown 10 1 24509-36 Class 600 or 900 bull Standard Betas 045 through 085 24509-37 Class 125 or 250 bull Headloss Percentage of differential pressure produced varies with beta ratio bull Installation Typically 0-3 diameters upstream and 0-1 diameters downstream Each V -Cone is sized for the intended a Ii cation S ecific erformance ratin s must be obtained throu

MODEL VW(H) DIMENSIONS

H L 2 1 8 (Note 2) B1- ~WE-D DC

~ I -rr --- - T - III

Lk-l - -- -- c-ttt- -- - -- -- - -- -

- - --- --- ---

I

--------------A------------~-t I A lor to 1 1lor to 24

DIMENSION TABLE

I

Size ANSI B165 Class 600 ANSI B165 Class 900 Stainless Carbon

0 E (Note 2) A (Note 1) B A(Note 2) B C (Note 2) C (Note 2)

inch inch mm inch mm inch mm inch mm inch mm inch mm inch mm NPT

y 1225 3112 563 1430 1288 3272 594 1509 0622 158 - - 084 213 Y Y 1263 3208 582 1478 1363 346 2 632 1605 0824 209 - - 105 267 Y 1 1300 3302 601 1527 1388 3526 644 1636 1049 26_64 gtshy - - 1315 334 Y 1Y 1550 3937 576 1463 1650 419 1 626 1590 1645 4178 - - 19 483 Y 2 1763 4478 631 1603 1988 5050 744 1890 2104 5344 - - 2375 603 )I

2)1 1800 4572 650 1651 2000 5080 750 1905 2504 6360 - - 2875 730 Y

3 2025 5144 663 1684 2175 5525 738 1875 3104 7884 - - 35 889 )I

4 2375 6033 788 2002 24 75 6287 838 2129 4090 1038 - - 45 114 Y

6 3100 7874 875 2223 3275 8319 963 2446 6065 1541 6065 1541 6625 168 Y

8 3600 9144 1001 254 3 3825 971 _6 1113 2827 7981 2027 7981 2027 8625 219 )I

10 3950 1003 1076 2733 4200 1067 1201 3051 1002 2545 1002 254 5 1075 273 Y

12 4175 1060 1113 2827 452 5 1149 1288 327 2 1200 3048 1194 3033 1275 323 Y

14 4225 1073 1213 3081 4600 1168 1400 3556 1325 336 6 1313 3335 14 355 Y

16 4325 1099 1263 3208 4625 1175 1413 3589 1525 3874 1500 3810 16 406 Y

18 4575 1162 1288 3272 4925 1251 1463 371 6 1725 438 2 1725 4382 18 457 Y

20 5025 )11276 11 1313 3335 5475 1391 1538 3907 1925 4890 1925 4890 20 508 Y

24 6325 1607 1763 4478 7025 1784 2113 536 7 2325 5906 2325 5906 24 609 Y 1 Overall length (A) tolerance vanes With line size jYto 1 plusmn18 (plusmn4mm) 1 jYto 10 plusmn316 (plusmn6mm) 12 to 24 plusmn14 (

2 Typical values shown

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-68111 Fax (909) 652-3078$ MQ[)MEIER Web Site httpWlNwmccrometercom e-mail infomccrometercom

Lit24509-36 Rev 146-00 copy2000 by McCrometcr Inc Printed in USA

I bull

CONFIGURAIiON SHEET MODEL NUMBER CONFIGURATION VW(H)

Pipe Size Materialsj Schedule FittingsEnd Connections

VW Q A 10OA S304V2 JLj CL 600 RF WN LtJ NPT

OB L S304L B 20 17 CL 900 RF WN S Socket 01 1 A S316L C Bored

Scvcmllypcs of ICS Tube amp Flanges 0 StdOC 1V2 ~ fittings aV01ilablc

2 40 00

S304 Cone Support amp Couplings E02 Epoxy Coated Blue (excluding cone) F 80

03 2V2 3 r-u CS Tube amp Flanges J 100

04 4 S304 Cone Support amp Couplings 120K jOther materials can include6 Coating Painting Per Customer Req 14006 L

-shy HASTELLOY C-276 S321H8 G 160 DUPLEX 2205 INCONEL 625

08 10 XXS

CHROMEMOLY P22PII 10 H

10S MONEL K400K500

12 M12 14 P XS

CARBON STEELS 14

16 -- shy

A350 A333 AP15L A 106B 16

18 20 18

20 24~

Example VW10AE16N V-Cone 10 inch line size S316L schedule 40 pipe ANSI CL 600 RF WN flanges V2NPT fittings

Type

STANDARD PIPE SCHEDUIpoundS Stainless Steel Carbon Steel

Size Std Size Std to 4 C

6 to 10 E 12 and up 0

6 to 16 18 and up

E 0

Pipe up to 8 utilizes seamless pipe Above 8 is welded pipe

ABBREVIATIONS ASME American Society of Mechanical Engineers NPT National pipe taper SS Stainless steel RF Raised Face CS Carbon steel WN Weld Neck

Technical questions can be answered through a local representative or through our application engineers

REPRESENTED BY

MANUFACTURING STANDARDS McCrometers welders and welding procedures are qualified in accordance with ASME Section IX All meters are visually inspected for weld defects Specific customer requirements can be complied with upon request

The welding can be in accordance with

bull ASME Section VIII

bull ASME B311

bull ASMEB313

Non-destmctive testing can include

bull Hydrostatic Pressure Testing

bull Penetrant Examination

bull Radiographic Examination

bull Positive Material Inspection

bull Magnetic Particle Examination

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-6811 Fax (909) 652-3078 Web Site httpwwwmccromelercom e-mail infomccrometercom

Lit24509-36 Rev 146-00 copy 2000 by McCrometer IncPrinted in USA

~----------------------~---------------------------------------------------------------------------

V -Cone Installation Guide Upstream and Downstream Minimum Straight Pipe Run Requirements

For Liquid Metering and Gases at a Reynolds Number (Re) Value Less Than or Equal To 200000

For fl greater than or equal to 065 add ID

Obstruction DownSize Range Up Stream Stream

I Elbow OD

2 Elbows

OD

OD OD

Tees OD OD Not Preferred ValveAll Sizes Butterfly Valve (control valve) DownstreamPosition

3D 3D

Butterfly Valve (shutoff valve) 3D OD

Full port Ballvalve (shutoff) OD OD

Heat Exchanger (Depends on Type) OD OD

Expander (067D to D) over a length ID ID of 2SD

Reducer (3D to D) over a length of ID ID 3SD

Note The meter and adjoining pipe should have equal IDs

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-6811 Fax (909) 652-3078 ~ MCOOMEIER Web Site http wwwmccrometercom e-mail infomccrometercom

Lit24S09-21 Rev 10102-04 copy2004 by McCrometer InclPrinted in USA

Product Data Sheet DAN-GFM-DS -21-rev0404 ( )

April2004 SeniorSonic with Mark TM Electronics

- SeniorSonic The Daniel SeniorSonic Gas Flow Meter with Mark IWM Electronics saves you time and money Lost and unaccounted for gas is reduced by exceptional low and high flow accuracy and linearity throughout the calibrated flow range Time is saved by a best-in-class audit trail Mark III Electronics can pinpoint alarms events and configuration changes in a matter of seconds Best of all operating the Daniel SeniorSonic gas flow meter is easy with the Windowsreg based Daniel Customer User Interface (CUI) software

Features middot Excellent long-term performance

Velocity Range Most sizes are rated to performa at 100 fps middot Full electronic audit trail (exceeds API 211) Over-range of up to 125 fps and in some cases beyond 125 middot Exceptional low and high flow performance

middot Bi-directional multi-point calibration coefficients fps in emergencymiddot situations and without transducer failure

middot Rangeability exceeds 50 1 with calibration Availability is limited by line size and ANSI rating Visit middot ANSI 30060090015002500 versions wwwdanielcomseniorsonic for additional information middot Extractable transducers (For all sizes) middot Minimum upstream piping requirements Meter specifications

Gas temperature -4 to +212deg F (-20 to +100deg C) Easy to learn and use CUI software features Operating pressure range 150 - 3750 psig middot Comprehensive monitor screen (1030 - 25855 kPa) Consult factory for lower and middot Field start-up wizard higher pressure applications middot Calibration wizards (analog and frequency) Flanges RF for 3001500 RTJ for 6002500 middot Flow calibration configuration wizard middot Audit 1 alarm 1history retrieval Power DC version - 1224 (11-36) VDC 6 watts maximum middot Digital waveform viewing middot Maintenance log summary in ExcelI Environmental middot Built-in AGA 10 SOS calculator Operating temperature -40 to +149deg F (-40 to +65deg C) middot Automatic file naming Operating relative humidity up to 95 non-condensing middot Trending of maintenance logs Storage temperature -40 to +185 0 F (-40 to +85 0 C) middot Configuration comparison with exception summary middot Remote dial-up support and Ethernet support Typical Applications middot Unlimited meter directory support middot Custody transfer

middot Power plants Specifications middot Large industrial users

Electronic unit middot City gates Communication protocol Modbus RTUASCII amp TCPIIP middot Production Two serial RS-232485 ports and Ethernet middot Underground storage sites Communication speed Up to 115 KBPS middot Offshore Frequency outputs Four Frequency range 0-10005000 Hz Safety classifications Digital output Selectable (up to four for data valid or flow UL listed for use in Class I Division 1 Group D hazardous

direction) locations in both the US and Canada (UL E152246) Calculation update time Configurable for 14 and 1 second CE marked to ATEX directive (949EC ) (pending)

Certified to Eex d ia liB T4 to standards EN 50014 EN 50018 Accuracy and EN 50020 (pending) Flow calibrated accuracy plusmn 01 (Relative to lab) Absolute accuracy Including lab uncertainty about 03 Repeatability plusmn 02 of reading for Ot to Omax

-- - tI II~ EMERSON ~-----

wwwdanielcom

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Recommended Ma~jum Flow Velocity Meter Size J Meter Size Metric Max Inches Max ftI~ m tris

4 100 100 30 6 100 150 30 8 100 200 30

10 80 250 24 12 80 300 24 16 85 400 26 20 85 500 26 24 85 600 26 30 70 750 21 36 70 900 21

Dimensions These measurements are meant only as an aid in the design of metering systems Consult Daniel engineering drawings prior to construction

Typical 600 ANSI Meter with 45 Degree-Angled Transducers Overall End- Flange Approximate Overall End- Flange Approximate

Meter Size To-End Diameter Weight To-End Diameter Weight (Inches) (Inches) (Inches) (Pounds) (Millimeters) (Millimeters) (Kilograms)

4 2900 1075 370 737 273 168 6 2950 1400 460 749 356 209

8 3150 1650 650 800 419 295 10 3400 2000 885 864 508 402 12 3544 2200 1075 900 559 489 16 4400 2700 1955 1118 686 889 18 4531 2925 2800 11sect1 743 1273 20 5062 3200 30Z5 12amp6 84~ 1398

0 4 5862 3700 404~ 1489 940 1839 30 6700 4450 4925 1702 1130 2239 36 7350 5175 6425 1867 1314 2920

()l p l ( C flO

bull I iY0

e

Page 2

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 60 F and gas composition These values are intended to be a guide in Contact Daniel engineering for a specific application

_ Flow Rates (JIISCFHl Basea Upon 100 ftls PSIG 4 6 8 10 12 16 20 24 30 36 100 247 561 971 1532 2174 3432 5398 7807 12607 18154 200 468 1065 1845 2908 4127 6515 10248 14822 23935 34467 300 696 1584 2743 4325 6137 9690 15240 22043 35596 51258 400 931 2118 3668 5782 8206 12955 20377 29472 47593 68534 500 2667 4619 7282 10334 16315 25661 37114 59934 86305 600 1421 3232 5597 8823 12522 19770 31095 44973 72626 104582 700 1676 3813 6602 10409 14772 23322 36682 53055 85677 123374 800 1938 4409 7635 12036 17082 26968 42417 61349 99070 142661 900 2207 5021 8694 13706 19452 30710 48302 69861 112816 162455 1000 2482 5646 9777 15414 21875 34536 54320 78565 126872 182696 1100 2763 6286 10885 17161 24355 38451 60478 87471 141254 203405 1200 3050 6939 12015 18943 26883 42443 66756 96551 155917 224521 1300 3341 7602 13164 20753 29453 46500 73137 105781 170822 245983 1400 3637 8274 14327 22587 32055 50608 79599 115127 185915 267718 1500 3935 8953 15504 24442 34688 54765 86137 124583 201184 289706 1600 4235 9635 16685 26305 37331 58938 92700 134076 216515 311781 1700 4536 10321 17871 28175 39986 63128 99291 143608 231908 333948 1800 4836 11002 19052 30036 42627 67298 105850 153094 247227 356006 1900 5134 11681 20226 31888 45255 71448 112376 162534 262471 377958 2000 5429 12350 21386 33716 47849 75543 118818 171851 277516 399623

Flow Rates (MIfIISCFfJ) Based Upon 100 ffls PSIG 4 6 8 10 12 16 20 24 30 36 100 59 135 233 368 522 824 1295 1874 3026 4357 200 113 256 443 698 990 1564 2459 3557 5744 8272 300 168 380 658 1038 1473 2326 3658 5290 8543 1230 400 224 508 880 1388 1969 3109 4890 7073 1142 1645 600 282 640 110~ 1748 2480 3916 6159 8907 1438 2071 600 342 776 1343 2118 3005 4745 7463 1079 1743 2510 700 403 915 1685 2498 3545 5597 8804 1273 2066 2961 800 466 1058 1832 2889 4100 6472 1018 1472 2378 3424 900 531 1205 2087 3289 4668 7370 1159 1677 2708 3899

1000 597 1355 2346 3699 5250 8289 1304 1886 3045 4385 1100 665 1509 2612 4119 5845 9228 1451 2099 3390 4882 1200 734 1665 2884 4546 6452 1019 1602 2317 3742 5389 1300 804 1824 3159 4981 7069 1116 1755 2539 4100 5904 1400 875 1986 3438 5421 7693 1215 1910 2763 4462 6425 1500 947 2149 3721 5866 8325 1314 2067 2990 4828 6953 1600 1019 2313 4004 6313 8960 1415 2225 3218 5196 7483 1700 1091 2477 4289 6762 9597 1515 2383 3447 5566middot 8015 1800 1164 2641 4572 7209 1023 1615 2540 3674 5933 8544 1900 1235 2803 4854 7653 1086 1715 2697 3901 6299 9071 2000 1306 2964 5133 8092 1148 1813 2852 4124 6660 9591

Calculating meter capacity To calculate a volume rate for a given velocity multiply the capacity in this table by the desired at the pressure and divide the answer by 100 Example Determine the hourly flow rate al 70 fps for an 8 inch meter operating at 800 psig Volume =7635 MSCFH Velocity 70 Answer = 763570100 = 5344 MSCFH

Pa~e 3

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 20 F and gas composition These values are intended to be a guide In Contact Daniel nee ring for a application

Flow RateS (IASOFH) Based UppJ1 30 mls Schedule 40) kPag 4 6 8 10 12 16 20 24 30 36 1000 967 2201 3811 6007 8527 1346 2117 3062 4945 7121 1500 1422 3234 5600 8827 1253 1978 3111 4500 7267 1046 2000 1885 4289 7428 1171 1662 2624 4127 5969 9639 1388 2500 2359 5367 9294 1465 2079 3283 5164 7469 1206 1737 3000 2843 6468 1120 1765 2506 3956 6223 9000 1453 2093 3500 3337 7592 1315 2072 2941 4644 7304 1056 1706 2457 4000 3841 8739 1513 2385 3386 5346 8408 1216 1964 2828 4500 4356 9910 171S 2705 3840 6062 9535 1379 2227 3207 5000 4881 1111 1923 3031 4303 6793 1068 1546 2495 3593 5500 5417 1232 2134 3364 4774 7538 1186 1715 2769 3987 6000 5962 1 3702 5255 8297 1305 1887 3048 4389 6500 6517 1483 2568 4047 5745 9070 1427 2063 3332 4798 7000 7082 1611 2790 4398 6243 9856 1550 2242 3621 5214 7500 7656 1742 3016 4754 6748 1065 1676 2424 3914 5636 8000 8238 1874 3246 5116 7262 1146 1803 2608 4212 6065 8500 8828 2009 3478 5482 7782 1229 1932 2795 4513 6499 9000 9425 2144 3713 5853 8308 1312 2063 2984 4818 6939 9500 10028 2281 3951 6227 8839 1396 2195 3175 5127 7382

10000 10636 2420 4190 6604 9375 1480 2328 3367 5437 7830

Flow Rates (IANSOND) Based Upon 30 mls (Scnedule 40) PSIG 4 6 8 10 12 16 20 24 30 36 1000 0232 0528 0915 1442 2046 3231 5082 7350 11869 17091 1500 0341 0776 1344 2119 3007 4748 7468 10801 17441 25116 2000 0453 1029 1783 2810 3989 6297 9904 14325 23133 33311 2500 0566 1288 2231 3516 4991 7879 12393 17924 28946 41682 3000 0682 1552 2688 4237 6014 9495 14935 21600 34882 50230 3500 0801 1821 3155 4973 7059 11145 17530 25354 40943 58958 4000 0922 2097 3632 5725 8126 12830 20179 29186 47131 67869 4500 1045 2378 4119 6492 9215 14549 22883 33097 53447 76963 5000 1171 2664 4615 7275 10326 16302 25641 37086 59889 86240 5500 1300 2957 5121 8072 11459 18091 28454 41154 66458 95699 6000 1431 3254 5637 8885 19912 31319 45298 73150 105336 6500 1564 3557 6162 9713 13787 21767 34236 49517 79964 115148 7000 1700 3866 6696 10555 14982 23653 37203 53808 86893 125126 7500 1837 4179 7239 11410 16196 25570 40218 58168 93934 135265 8000 1977 4497 7789 12278 17428 27515 43277 62592 101078 145553 8500 2119 4819 8347 13157 18676 29485 46376 67075 108318 155978 9000 2262 51 8912 14047 19939 31479 71611 115642 166524 9500 2407 5474 9482 14945 21214 33492 52679 76191 123038 177175

10000 2553 5805 10056 15851 22500 35522 55871 80808 130494 187911

Calculating meter capacity To calculate a volume rate for a given velocity the capacity this table by the desired velocity at the operating pressure and divide the answer 100 Determine the hourly flow rate at 30 mps for an 8 inch meter at 4500 Volume 1716 Velocity 10 Answer 17161030 5719 MSCMH

Product Oata Sheet DAN-GFM-DS-21-rev0404 April 2004

The drawings below represent recommended piping lengths for various flow conditioners when installed with the Daniel SeniorSonic flowmeter If shorter lengths are used there may be an increase in flow measurement uncertainty

Piping Recommendation For SeniorSonic With No Flow Conditioner

1~~--------------------200 -----------------------~

Q----I__------shy~

J ~~f --M-I-middotn-im-~-~-p-iP-i-n-g-R-e-c-o-m-m-e-n-a-a-tl-o-n-F-o-r-S-en-I-o-r-S-o-n-ic-W-it-h-D-a-n-ie-l-p-r-O-fi-le-r-o-r-C-p-~-5-0-E~-F--o-w-c-o-n-d-itl-io-n-e-r--

1 00 middot -2 o~o ~1gt

[ _____ ---Al11~ ----- =ul [II I

I 0 0 a It Minimum Piping Recommendation for Bimiddotdirectional SeniorSonic

with Daniel Profiler or CPA 50E Flow Conditioner

~------- 100 ------t ~------- 100 ----~ - 50---shy

3middot 50

-- 50 ---shy

3middot 50

~ -

A WARNING Do not operate this instrument in excess of the specifications listed Failure to heed this warning could result in serious injury andor damage to the equipment

Page 5

---- - --- _ --- ----------------- -------------------------shy

--iI

-------~~--------1

----~----------------I _____________________I

----~------~----__i _____bullmiddot________ ----__i

____________shy____~__i

____________________---i __________________

_________shy__________~~

~ I ~

I

~

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

8

10

12

16

20

24

30

36 r

ANSI Class 300 600--~------------------------i

900__________----__------__------i 1500

-------------------------------~ Flange Raised Face (RF) _________________-_------j

Ring Type Joint (RTJ)___---------__bull-_____Imiddot

Materials Standard ~----~~--~----~--------~~ Stainless Steel

DJplex --~--------------------------~----~ _________________________--____~__

Device Type

Electronics

Transducers

Meter Size (Inches)

Daniel Ultrasonic Model Number Selections ES-21055 RevW

SeniorSonic (4-Path) ---------------1 JuniorSonic (1~Path) ------------1 JuniorSonic (2-Path) ______________

Mark II UL 24VDC 4-20rlA 3NPT

Mark UL 24VDC 1middot5VDC 3NPT ---------------------1 Mark CENaEC 24V DC 4-20mA M20 --------------_--__1

Mark IICB-JELEC24VDC1-SVDCM20

Mark II ClNELEc 24VDC 4-20mA M20 Rerrote

Mark II CENELEC 24VDC 1-5VDCM20 Rerrote

MarkU UL 24VOC4-20mA 3NPT Rerrote_

Mark II U~ 24VDC l-SVPG 3NPT Rerrote

Mark IIIUL 34 NPT

Mark III UL 34NPT Rerrote

TmiddotSlo T-12

4

middot 6

Page 6

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Systems Daniel Measurement and Control is the industry leader in designing constructing and commissioning of complex oil and gas metering systems to exacting standards

This global organization offers decades of petroleum fiscal flow measurement application experience Customers rely confidently on Daniels Systems Group international fabrication facilities customized engineering and its successes in field-testing and support From the simplest single-stream skid to complex on-site installations Daniel Systems delivers both natural gas and liquid petroleum tumkey applications Daniel Systems designs constructs and commissions the metering project blending up-toshythe-minute technology with decades of understanding what customers need and expect

Components of a Daniel Systems installation typically include meters valves provers flow-control instruments instrumentation and read-out equipment and process management components

Computer software and hardware are integrated with the measurement system Standard calculation methods include AGA3 (now API-MPMS-143) ISO 5167 AGA578 AGA9 and the API Manual for Petroleum Measurement Standards

Daniel DMSS-2000 Supervisory Control Systems utilize a sophisticated Graphical User Interface database server and a dedicated PLC for the metering skidMOV interface Redundancy is often used for custody transfer systems andor when system integrity is essential

A dedicated Project Manager and Project Team are assigned to each measurement system project This team is responsible for overall system design and project construction from start to finish A separate internal QAQC group reviews all design detailS inside and outside fabrication assembly and system testing

Whether it is a pipeline offshore production facility or a loading facility for ocean-going tankers the Daniel Systems group is a proven single-source solution for customers throughout the world

Page 7

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Daniel Measurement Services Daniel Measurement Services takes pride in being there after needs arise with the right solution for customers with gas and liquid fiscal flow measurement applications

Around the clock and around the world Daniel Measurement Services has experienced highly qualified people prepared to help customers who need assistance with the following

middot Start-up and commissioning middot Preventive maintenance middot Product repair I upgrades middot Project management and integration middot Meter Tube inspection and recertification middot Remote diagnostics middot Warranty Plus middot Technical training

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880

Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337

Stirling Scotland - UK Middle East amp Africa T +4401786433400 F +44 01786433401

Singapore - Asia Pacific T +65-6777-8211 F +65-6770-8001

USA Toll Free 1-888-FLOW-001 wwwdanielcom

Daniel is a whOlly owned subsidiary of Emerson Electric Co and a division of Emerson Process Management The Daniel logo is a registered trademark of Daniel Industnes tnc The Emerson logo is a trademark and service mark of Emerson Electric Co Brand mark listing are marks of one of the Emerson Process Management family of companies All other marks are property of their respecl ive owners The Daniel UltraSonic Gas Flow Meter including Mark III electronics is covered by US Patents 598330 and 4646 575 and patents pending The contents of this publication are presented for information purposes only and while effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or thel( use or applicability Daniel does not assume responsibility for the selection use or maintenance of any Daniel product Responsibility for proper selection use and maintenance of any Daniel product remains solely wilh the purchaser and end-userAII sales are governed by our terms and conditions which are available upon request We reserve the right to modify or improve the designs or specification of our products at any time without notice

-- -~J ~~--------- EMERSON bull ~ I

copy2004 Daniel Measurement and Control Inc All rights reserved Printed in the USA DAN -GFM-DS-0221-rev0404

reg DAN-3MT-3M-0801 -~I August 2001_-shy

3 SectioQltandProfiler Meter Tubes ~ Pf~6 5 ~~ IrMimiddot~

Instruments You Can Trust Daniel Meter Tubes are more than just fabricated pipe with an orifice fitting They are accurate dependable instruments because of Daniels dedicated approach to quality Extra steps taken during every phase of meter tube design and production separate Daniel Meter Tubes from all the rest

The Daniel 3 section meter tube is available with any style Senior or Junior orifice fitting Simplex plate holder or orifice flanges The assembly contains an inlet spool of the minimum length prescribed by the 143 standard The second section begins with a concentric flange mounted tube bund=1 leetln9 the 2000 API 143 requirements and a W thick spacer plate to ease tube removal for inspection The 04~r end of section 2 conshytains the orifice flange or fitting The third or downstream section follows and contains 2 branchOonnections and is extra long to allow for the addition of extra branch conshynections in the field If desired The standard meter tube has flanged outer ends Other end connections are avaUable on request

Inspectionffesting= Daniel maintains rigid inspection procedures during manufacturing of meter tubes Micrometer and internal surface roughness readings are recorded and supplied with each meter tUbe Customer or third party inspectors are welcome to verify these readings Radiography of welds is another service that is available

Fabrication Fabrication of your instrument Includes attaching the orifice fitting to the meter tube to make an integral primary measuring element For welding operashytions Daniel uses automatic welding machines and rotatshying positioners Highly skilled code qualified welders are employed to tum out highest quality on each job Special internal jigs and fixtures are used to insure smooth Inlet and outlet surfaces without steps or offsets All welds receive expert grinding by experienced craftsshy

men X

cl

-

gt shy

~

-

J ~

Features bull Dowel pin alignment close tolerance maleffemale

flange or knock out dowel pins insure that the bores of sections two and three are matched without offsets

One 1h and one 0 branch connection on the downstream for thermowell or other uses standard

Beveled flanged or reduced ends as well as any available weld fitting can be furnished on the ends of the tubes

Hydrostatically tested after manufacture

Each orifice fitting is tested for tap hole and orifice plate seal integrity after the meter tube has been pressure tested

Material Selection Daniel uses special cold drawn seamless tubing or honed pipe in the fabrication of meter tubes The strict reqUirements for intemal roundshyness and surface finish preclude the use of standard commercial pipe in most cases Daniel maintains a large inventory of this special pipe to rapidly complete your order

LT

EMERSON~ ltocess Management

~~------------------------------------------------------------~------------------------------

Raised Face Weld neck

NA

3M-30RW

3M-60RW High Pressure

3M-90RW 3M-150RW 3M-250RW

DAN-3MT-3M-0801 August 2001

3 Section Meter Tube Catalog Numbers 2-12 with Senior Fitting 10 amp 12 with Junior Fittina

~

Pressure Rating

150

Flange by Weld

(Flangnek)

3M-011

Flange by Flange

(Flanged)

3M-101

Weld by Weld

(Weldnek)

NA

Flange by Weld

(Flangnek)

3M-021

Flange by Flange

(Flanged)

3M-201

Weld by Weld

(Weldnek)

NA

300 3M-013 3M-103 NA 3M-023 3M-203 NA

600 3M-015 3M-105 3M-185 3M-025 3M-205 3M-285

H~h Pressure 3 Section Meter Tubes 900 3M-016 3M-106 3M-186 3M-026 3M-206 3M-286

1500 3M-017 3M-107 3M-187 3M-027 3M-207 3M-287

2500 3M-018 3M-108 3M-188 3M-028 3M-208 3M-288

2middot8 with Simplex 2middot12 with Orifice Flanges Flange byPressure

WeldRating Weld by Weld (Flangnek) (Weldnek)

150 3M-071 NA 3M-073300 NA

600 3M-075 3M-705 High Pressure

3M-7063M-076900 3M-7071500 3M-077 3M-7083M-0782500 -

Two Section Meter Tubes When Usmg Weldnek Flttmgs

Senior and Simplex fittings are also available in 10000 psi rating in some sizes All units are also available with Ring Type Joint (RTJ) flanges on request Sizes larger than 12 available on request

PackingShipping Daniel bolts together all meter A SPECIAL NOTE The use of factory original Daniel tubes when size permits before shipment This saves parts will assure your Senior Junior and Simplex Orifice the user time and field labor costs Fittings are protectshy fittings will stay within original specifications and operate ed by heavy lumber and the tube flanges by special-cut properly protectors

PaintingCoating The Daniel standard paint is a basic enamel type Special coatings such as multi-coat

offshore systems are available on request

3~Section Meter Tube with Tube Bundle

~-----~ U ----~---------~=~~middotmiddotmiddotmiddot~middot t)middotmiddot-middot ~- - -0bull )00)00 1

I~IC--middotmiddotmiddot-middot -----shyshy-bullmiddotV ------- ~

~ - ~-

~

ii~pound bullbullbull ~

Standard lenAths Size un Upstream 0 Downstream V (vane location)

3 7-5 4-0 130 4 9~~9 4-0 130

6 14-8 5-0 t30

102410 60middot middot 130 1~ +1 2tYS Tq 130 JiIf

Note Straightening vanes are not available in 2line size (See Dald Profller DAN-1852middot 2M)

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Daniel meter tubes can be supshyplied in many combinations and configurations Any of the orifice fittings plate holders or orifice flanges can be included in a meter tube Each 3 section standard meter tube is equipped with a flange mounted tube bundle straightener In accordance with April 2000 API 143 and a 1h thick spacer to facilitate tube removal for inspection Downstreams are longer than minimum required to allow for field Installation of additional branch connections If required

To specify a 3 section meter tube use the designation 3M followed by the type orifice holding deVice Ex 4 600 3 section meter tube with flanged ends using a Senior fitting flangneck style is specified as 4-3M-015 The same unit with a weldneck style Simplex is specified as 4middot3M-705 When ordering specify pipe schedule and end configuration Larger size and custom meter tube designs are available on request

The Daniel Profilertrade three section meter tube is availshy lows and contains 2 branch connections Other or addi able with any style Senior or Junior orifice fitting Simplex tiona I connections can be supplied in this section on plate holder or orifice flanges The assembly contains an request These meter tubes are for use in any piping conshyinlet spool of tile minimum length determined during testshy figuration with beta ratios to 67 Downstream sections ing to the API 143 standard The flange union between are extra long to allow for the addition of extra branch the first and second sections contains the ProfilerN and connections in the field if desired The standard meter a Y2 thick spacer plate to facilitate tube removal for tube has beveled outer ends Flanges or other end conshyinspection The outer end of section 2 contains the orishy nections are available on request fice flange or fitting The third or downstream section fol

Meter Tubes Catalog Numbers - 2 WI emor In9 bull Wit un or Itt ng2 1 th S Fitt 10 amp 12 h J i F i

Pressure Rating

Flange by Weld

(F1angnek)

Flange by Flange

(Flanged)

Weld by Weld

(Weldnek)

Flange by Weld

(Flangnek)

Flange by Flange

(Flanged)

Weld by Weld

(WeJdnek) 150 M011 M-101 NA M-021 M-201 NA 300 M-Q13 M-103 NA M023 M-203

NA 600 M-015 M-105 M-t85 M-025 M-205 M-285

2middot8 with Simplex 2middot12 with Orifice Flanges

Pressure Rating

Flange by Weld

weld by Weld

(Weldnek)CFlananekl 150 M-071 NA 300 M-073 NJA 6QfJ M-()75 M-705

Raised Face Weld Neck

NA - -

lM-30RW M-60RW

Two Section Meter Tube When USing Weldnek Fittings

Consult Factory for High Pressure Applications

PROFILERTM Flow Conditioning Plate

The Profiler has been tested and Shown to be in full compliance with the requirementS of API 143 April 2000 The Profiler both removes swirl

the tube bundle Available In flange mounted model only Also available In RTJ style on request

and creates a fully developed flow profile at the orifice Use of this unit allows shortened upstream straight pipe lengths of 17 diameters Beta ratio limit is 67 as with

-~---

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 6: Medidor de Flujo

yeoNE reg CONFIGURATION SHEET

PRECISION TUBE SERIESMODELVW (H)

ANSI 8165 Weld Neck Raised Face Flanges - Class 600 or 900

DESCRIPIION AND GENERAL PERFORMANCE SPECIFICATIONS The V -Conereg flowmeter is a patented differential pressure type flow measurement device A cone is positioned in the center of the pipe to increase the velocity of the flowing fluid and create a differential pressure This pressure difference can be measured and used to accurately interpret flowrate Two taps are provided on every V -Cone to allow sensing of the high and low pressures A typical V-Cone application can follow these general performance specifications bull Accuracy up to plusmn05 of rate Model VW Bulletins

ANSI 8165 Weld Neck RF Flanges 24509-35 Class 150 or 300

bull Repeatability plusmnO J bull Turndown 10 1 24509-36 Class 600 or 900 bull Standard Betas 045 through 085 24509-37 Class 125 or 250 bull Headloss Percentage of differential pressure produced varies with beta ratio bull Installation Typically 0-3 diameters upstream and 0-1 diameters downstream Each V -Cone is sized for the intended a Ii cation S ecific erformance ratin s must be obtained throu

MODEL VW(H) DIMENSIONS

H L 2 1 8 (Note 2) B1- ~WE-D DC

~ I -rr --- - T - III

Lk-l - -- -- c-ttt- -- - -- -- - -- -

- - --- --- ---

I

--------------A------------~-t I A lor to 1 1lor to 24

DIMENSION TABLE

I

Size ANSI B165 Class 600 ANSI B165 Class 900 Stainless Carbon

0 E (Note 2) A (Note 1) B A(Note 2) B C (Note 2) C (Note 2)

inch inch mm inch mm inch mm inch mm inch mm inch mm inch mm NPT

y 1225 3112 563 1430 1288 3272 594 1509 0622 158 - - 084 213 Y Y 1263 3208 582 1478 1363 346 2 632 1605 0824 209 - - 105 267 Y 1 1300 3302 601 1527 1388 3526 644 1636 1049 26_64 gtshy - - 1315 334 Y 1Y 1550 3937 576 1463 1650 419 1 626 1590 1645 4178 - - 19 483 Y 2 1763 4478 631 1603 1988 5050 744 1890 2104 5344 - - 2375 603 )I

2)1 1800 4572 650 1651 2000 5080 750 1905 2504 6360 - - 2875 730 Y

3 2025 5144 663 1684 2175 5525 738 1875 3104 7884 - - 35 889 )I

4 2375 6033 788 2002 24 75 6287 838 2129 4090 1038 - - 45 114 Y

6 3100 7874 875 2223 3275 8319 963 2446 6065 1541 6065 1541 6625 168 Y

8 3600 9144 1001 254 3 3825 971 _6 1113 2827 7981 2027 7981 2027 8625 219 )I

10 3950 1003 1076 2733 4200 1067 1201 3051 1002 2545 1002 254 5 1075 273 Y

12 4175 1060 1113 2827 452 5 1149 1288 327 2 1200 3048 1194 3033 1275 323 Y

14 4225 1073 1213 3081 4600 1168 1400 3556 1325 336 6 1313 3335 14 355 Y

16 4325 1099 1263 3208 4625 1175 1413 3589 1525 3874 1500 3810 16 406 Y

18 4575 1162 1288 3272 4925 1251 1463 371 6 1725 438 2 1725 4382 18 457 Y

20 5025 )11276 11 1313 3335 5475 1391 1538 3907 1925 4890 1925 4890 20 508 Y

24 6325 1607 1763 4478 7025 1784 2113 536 7 2325 5906 2325 5906 24 609 Y 1 Overall length (A) tolerance vanes With line size jYto 1 plusmn18 (plusmn4mm) 1 jYto 10 plusmn316 (plusmn6mm) 12 to 24 plusmn14 (

2 Typical values shown

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-68111 Fax (909) 652-3078$ MQ[)MEIER Web Site httpWlNwmccrometercom e-mail infomccrometercom

Lit24509-36 Rev 146-00 copy2000 by McCrometcr Inc Printed in USA

I bull

CONFIGURAIiON SHEET MODEL NUMBER CONFIGURATION VW(H)

Pipe Size Materialsj Schedule FittingsEnd Connections

VW Q A 10OA S304V2 JLj CL 600 RF WN LtJ NPT

OB L S304L B 20 17 CL 900 RF WN S Socket 01 1 A S316L C Bored

Scvcmllypcs of ICS Tube amp Flanges 0 StdOC 1V2 ~ fittings aV01ilablc

2 40 00

S304 Cone Support amp Couplings E02 Epoxy Coated Blue (excluding cone) F 80

03 2V2 3 r-u CS Tube amp Flanges J 100

04 4 S304 Cone Support amp Couplings 120K jOther materials can include6 Coating Painting Per Customer Req 14006 L

-shy HASTELLOY C-276 S321H8 G 160 DUPLEX 2205 INCONEL 625

08 10 XXS

CHROMEMOLY P22PII 10 H

10S MONEL K400K500

12 M12 14 P XS

CARBON STEELS 14

16 -- shy

A350 A333 AP15L A 106B 16

18 20 18

20 24~

Example VW10AE16N V-Cone 10 inch line size S316L schedule 40 pipe ANSI CL 600 RF WN flanges V2NPT fittings

Type

STANDARD PIPE SCHEDUIpoundS Stainless Steel Carbon Steel

Size Std Size Std to 4 C

6 to 10 E 12 and up 0

6 to 16 18 and up

E 0

Pipe up to 8 utilizes seamless pipe Above 8 is welded pipe

ABBREVIATIONS ASME American Society of Mechanical Engineers NPT National pipe taper SS Stainless steel RF Raised Face CS Carbon steel WN Weld Neck

Technical questions can be answered through a local representative or through our application engineers

REPRESENTED BY

MANUFACTURING STANDARDS McCrometers welders and welding procedures are qualified in accordance with ASME Section IX All meters are visually inspected for weld defects Specific customer requirements can be complied with upon request

The welding can be in accordance with

bull ASME Section VIII

bull ASME B311

bull ASMEB313

Non-destmctive testing can include

bull Hydrostatic Pressure Testing

bull Penetrant Examination

bull Radiographic Examination

bull Positive Material Inspection

bull Magnetic Particle Examination

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-6811 Fax (909) 652-3078 Web Site httpwwwmccromelercom e-mail infomccrometercom

Lit24509-36 Rev 146-00 copy 2000 by McCrometer IncPrinted in USA

~----------------------~---------------------------------------------------------------------------

V -Cone Installation Guide Upstream and Downstream Minimum Straight Pipe Run Requirements

For Liquid Metering and Gases at a Reynolds Number (Re) Value Less Than or Equal To 200000

For fl greater than or equal to 065 add ID

Obstruction DownSize Range Up Stream Stream

I Elbow OD

2 Elbows

OD

OD OD

Tees OD OD Not Preferred ValveAll Sizes Butterfly Valve (control valve) DownstreamPosition

3D 3D

Butterfly Valve (shutoff valve) 3D OD

Full port Ballvalve (shutoff) OD OD

Heat Exchanger (Depends on Type) OD OD

Expander (067D to D) over a length ID ID of 2SD

Reducer (3D to D) over a length of ID ID 3SD

Note The meter and adjoining pipe should have equal IDs

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-6811 Fax (909) 652-3078 ~ MCOOMEIER Web Site http wwwmccrometercom e-mail infomccrometercom

Lit24S09-21 Rev 10102-04 copy2004 by McCrometer InclPrinted in USA

Product Data Sheet DAN-GFM-DS -21-rev0404 ( )

April2004 SeniorSonic with Mark TM Electronics

- SeniorSonic The Daniel SeniorSonic Gas Flow Meter with Mark IWM Electronics saves you time and money Lost and unaccounted for gas is reduced by exceptional low and high flow accuracy and linearity throughout the calibrated flow range Time is saved by a best-in-class audit trail Mark III Electronics can pinpoint alarms events and configuration changes in a matter of seconds Best of all operating the Daniel SeniorSonic gas flow meter is easy with the Windowsreg based Daniel Customer User Interface (CUI) software

Features middot Excellent long-term performance

Velocity Range Most sizes are rated to performa at 100 fps middot Full electronic audit trail (exceeds API 211) Over-range of up to 125 fps and in some cases beyond 125 middot Exceptional low and high flow performance

middot Bi-directional multi-point calibration coefficients fps in emergencymiddot situations and without transducer failure

middot Rangeability exceeds 50 1 with calibration Availability is limited by line size and ANSI rating Visit middot ANSI 30060090015002500 versions wwwdanielcomseniorsonic for additional information middot Extractable transducers (For all sizes) middot Minimum upstream piping requirements Meter specifications

Gas temperature -4 to +212deg F (-20 to +100deg C) Easy to learn and use CUI software features Operating pressure range 150 - 3750 psig middot Comprehensive monitor screen (1030 - 25855 kPa) Consult factory for lower and middot Field start-up wizard higher pressure applications middot Calibration wizards (analog and frequency) Flanges RF for 3001500 RTJ for 6002500 middot Flow calibration configuration wizard middot Audit 1 alarm 1history retrieval Power DC version - 1224 (11-36) VDC 6 watts maximum middot Digital waveform viewing middot Maintenance log summary in ExcelI Environmental middot Built-in AGA 10 SOS calculator Operating temperature -40 to +149deg F (-40 to +65deg C) middot Automatic file naming Operating relative humidity up to 95 non-condensing middot Trending of maintenance logs Storage temperature -40 to +185 0 F (-40 to +85 0 C) middot Configuration comparison with exception summary middot Remote dial-up support and Ethernet support Typical Applications middot Unlimited meter directory support middot Custody transfer

middot Power plants Specifications middot Large industrial users

Electronic unit middot City gates Communication protocol Modbus RTUASCII amp TCPIIP middot Production Two serial RS-232485 ports and Ethernet middot Underground storage sites Communication speed Up to 115 KBPS middot Offshore Frequency outputs Four Frequency range 0-10005000 Hz Safety classifications Digital output Selectable (up to four for data valid or flow UL listed for use in Class I Division 1 Group D hazardous

direction) locations in both the US and Canada (UL E152246) Calculation update time Configurable for 14 and 1 second CE marked to ATEX directive (949EC ) (pending)

Certified to Eex d ia liB T4 to standards EN 50014 EN 50018 Accuracy and EN 50020 (pending) Flow calibrated accuracy plusmn 01 (Relative to lab) Absolute accuracy Including lab uncertainty about 03 Repeatability plusmn 02 of reading for Ot to Omax

-- - tI II~ EMERSON ~-----

wwwdanielcom

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Recommended Ma~jum Flow Velocity Meter Size J Meter Size Metric Max Inches Max ftI~ m tris

4 100 100 30 6 100 150 30 8 100 200 30

10 80 250 24 12 80 300 24 16 85 400 26 20 85 500 26 24 85 600 26 30 70 750 21 36 70 900 21

Dimensions These measurements are meant only as an aid in the design of metering systems Consult Daniel engineering drawings prior to construction

Typical 600 ANSI Meter with 45 Degree-Angled Transducers Overall End- Flange Approximate Overall End- Flange Approximate

Meter Size To-End Diameter Weight To-End Diameter Weight (Inches) (Inches) (Inches) (Pounds) (Millimeters) (Millimeters) (Kilograms)

4 2900 1075 370 737 273 168 6 2950 1400 460 749 356 209

8 3150 1650 650 800 419 295 10 3400 2000 885 864 508 402 12 3544 2200 1075 900 559 489 16 4400 2700 1955 1118 686 889 18 4531 2925 2800 11sect1 743 1273 20 5062 3200 30Z5 12amp6 84~ 1398

0 4 5862 3700 404~ 1489 940 1839 30 6700 4450 4925 1702 1130 2239 36 7350 5175 6425 1867 1314 2920

()l p l ( C flO

bull I iY0

e

Page 2

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 60 F and gas composition These values are intended to be a guide in Contact Daniel engineering for a specific application

_ Flow Rates (JIISCFHl Basea Upon 100 ftls PSIG 4 6 8 10 12 16 20 24 30 36 100 247 561 971 1532 2174 3432 5398 7807 12607 18154 200 468 1065 1845 2908 4127 6515 10248 14822 23935 34467 300 696 1584 2743 4325 6137 9690 15240 22043 35596 51258 400 931 2118 3668 5782 8206 12955 20377 29472 47593 68534 500 2667 4619 7282 10334 16315 25661 37114 59934 86305 600 1421 3232 5597 8823 12522 19770 31095 44973 72626 104582 700 1676 3813 6602 10409 14772 23322 36682 53055 85677 123374 800 1938 4409 7635 12036 17082 26968 42417 61349 99070 142661 900 2207 5021 8694 13706 19452 30710 48302 69861 112816 162455 1000 2482 5646 9777 15414 21875 34536 54320 78565 126872 182696 1100 2763 6286 10885 17161 24355 38451 60478 87471 141254 203405 1200 3050 6939 12015 18943 26883 42443 66756 96551 155917 224521 1300 3341 7602 13164 20753 29453 46500 73137 105781 170822 245983 1400 3637 8274 14327 22587 32055 50608 79599 115127 185915 267718 1500 3935 8953 15504 24442 34688 54765 86137 124583 201184 289706 1600 4235 9635 16685 26305 37331 58938 92700 134076 216515 311781 1700 4536 10321 17871 28175 39986 63128 99291 143608 231908 333948 1800 4836 11002 19052 30036 42627 67298 105850 153094 247227 356006 1900 5134 11681 20226 31888 45255 71448 112376 162534 262471 377958 2000 5429 12350 21386 33716 47849 75543 118818 171851 277516 399623

Flow Rates (MIfIISCFfJ) Based Upon 100 ffls PSIG 4 6 8 10 12 16 20 24 30 36 100 59 135 233 368 522 824 1295 1874 3026 4357 200 113 256 443 698 990 1564 2459 3557 5744 8272 300 168 380 658 1038 1473 2326 3658 5290 8543 1230 400 224 508 880 1388 1969 3109 4890 7073 1142 1645 600 282 640 110~ 1748 2480 3916 6159 8907 1438 2071 600 342 776 1343 2118 3005 4745 7463 1079 1743 2510 700 403 915 1685 2498 3545 5597 8804 1273 2066 2961 800 466 1058 1832 2889 4100 6472 1018 1472 2378 3424 900 531 1205 2087 3289 4668 7370 1159 1677 2708 3899

1000 597 1355 2346 3699 5250 8289 1304 1886 3045 4385 1100 665 1509 2612 4119 5845 9228 1451 2099 3390 4882 1200 734 1665 2884 4546 6452 1019 1602 2317 3742 5389 1300 804 1824 3159 4981 7069 1116 1755 2539 4100 5904 1400 875 1986 3438 5421 7693 1215 1910 2763 4462 6425 1500 947 2149 3721 5866 8325 1314 2067 2990 4828 6953 1600 1019 2313 4004 6313 8960 1415 2225 3218 5196 7483 1700 1091 2477 4289 6762 9597 1515 2383 3447 5566middot 8015 1800 1164 2641 4572 7209 1023 1615 2540 3674 5933 8544 1900 1235 2803 4854 7653 1086 1715 2697 3901 6299 9071 2000 1306 2964 5133 8092 1148 1813 2852 4124 6660 9591

Calculating meter capacity To calculate a volume rate for a given velocity multiply the capacity in this table by the desired at the pressure and divide the answer by 100 Example Determine the hourly flow rate al 70 fps for an 8 inch meter operating at 800 psig Volume =7635 MSCFH Velocity 70 Answer = 763570100 = 5344 MSCFH

Pa~e 3

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 20 F and gas composition These values are intended to be a guide In Contact Daniel nee ring for a application

Flow RateS (IASOFH) Based UppJ1 30 mls Schedule 40) kPag 4 6 8 10 12 16 20 24 30 36 1000 967 2201 3811 6007 8527 1346 2117 3062 4945 7121 1500 1422 3234 5600 8827 1253 1978 3111 4500 7267 1046 2000 1885 4289 7428 1171 1662 2624 4127 5969 9639 1388 2500 2359 5367 9294 1465 2079 3283 5164 7469 1206 1737 3000 2843 6468 1120 1765 2506 3956 6223 9000 1453 2093 3500 3337 7592 1315 2072 2941 4644 7304 1056 1706 2457 4000 3841 8739 1513 2385 3386 5346 8408 1216 1964 2828 4500 4356 9910 171S 2705 3840 6062 9535 1379 2227 3207 5000 4881 1111 1923 3031 4303 6793 1068 1546 2495 3593 5500 5417 1232 2134 3364 4774 7538 1186 1715 2769 3987 6000 5962 1 3702 5255 8297 1305 1887 3048 4389 6500 6517 1483 2568 4047 5745 9070 1427 2063 3332 4798 7000 7082 1611 2790 4398 6243 9856 1550 2242 3621 5214 7500 7656 1742 3016 4754 6748 1065 1676 2424 3914 5636 8000 8238 1874 3246 5116 7262 1146 1803 2608 4212 6065 8500 8828 2009 3478 5482 7782 1229 1932 2795 4513 6499 9000 9425 2144 3713 5853 8308 1312 2063 2984 4818 6939 9500 10028 2281 3951 6227 8839 1396 2195 3175 5127 7382

10000 10636 2420 4190 6604 9375 1480 2328 3367 5437 7830

Flow Rates (IANSOND) Based Upon 30 mls (Scnedule 40) PSIG 4 6 8 10 12 16 20 24 30 36 1000 0232 0528 0915 1442 2046 3231 5082 7350 11869 17091 1500 0341 0776 1344 2119 3007 4748 7468 10801 17441 25116 2000 0453 1029 1783 2810 3989 6297 9904 14325 23133 33311 2500 0566 1288 2231 3516 4991 7879 12393 17924 28946 41682 3000 0682 1552 2688 4237 6014 9495 14935 21600 34882 50230 3500 0801 1821 3155 4973 7059 11145 17530 25354 40943 58958 4000 0922 2097 3632 5725 8126 12830 20179 29186 47131 67869 4500 1045 2378 4119 6492 9215 14549 22883 33097 53447 76963 5000 1171 2664 4615 7275 10326 16302 25641 37086 59889 86240 5500 1300 2957 5121 8072 11459 18091 28454 41154 66458 95699 6000 1431 3254 5637 8885 19912 31319 45298 73150 105336 6500 1564 3557 6162 9713 13787 21767 34236 49517 79964 115148 7000 1700 3866 6696 10555 14982 23653 37203 53808 86893 125126 7500 1837 4179 7239 11410 16196 25570 40218 58168 93934 135265 8000 1977 4497 7789 12278 17428 27515 43277 62592 101078 145553 8500 2119 4819 8347 13157 18676 29485 46376 67075 108318 155978 9000 2262 51 8912 14047 19939 31479 71611 115642 166524 9500 2407 5474 9482 14945 21214 33492 52679 76191 123038 177175

10000 2553 5805 10056 15851 22500 35522 55871 80808 130494 187911

Calculating meter capacity To calculate a volume rate for a given velocity the capacity this table by the desired velocity at the operating pressure and divide the answer 100 Determine the hourly flow rate at 30 mps for an 8 inch meter at 4500 Volume 1716 Velocity 10 Answer 17161030 5719 MSCMH

Product Oata Sheet DAN-GFM-DS-21-rev0404 April 2004

The drawings below represent recommended piping lengths for various flow conditioners when installed with the Daniel SeniorSonic flowmeter If shorter lengths are used there may be an increase in flow measurement uncertainty

Piping Recommendation For SeniorSonic With No Flow Conditioner

1~~--------------------200 -----------------------~

Q----I__------shy~

J ~~f --M-I-middotn-im-~-~-p-iP-i-n-g-R-e-c-o-m-m-e-n-a-a-tl-o-n-F-o-r-S-en-I-o-r-S-o-n-ic-W-it-h-D-a-n-ie-l-p-r-O-fi-le-r-o-r-C-p-~-5-0-E~-F--o-w-c-o-n-d-itl-io-n-e-r--

1 00 middot -2 o~o ~1gt

[ _____ ---Al11~ ----- =ul [II I

I 0 0 a It Minimum Piping Recommendation for Bimiddotdirectional SeniorSonic

with Daniel Profiler or CPA 50E Flow Conditioner

~------- 100 ------t ~------- 100 ----~ - 50---shy

3middot 50

-- 50 ---shy

3middot 50

~ -

A WARNING Do not operate this instrument in excess of the specifications listed Failure to heed this warning could result in serious injury andor damage to the equipment

Page 5

---- - --- _ --- ----------------- -------------------------shy

--iI

-------~~--------1

----~----------------I _____________________I

----~------~----__i _____bullmiddot________ ----__i

____________shy____~__i

____________________---i __________________

_________shy__________~~

~ I ~

I

~

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

8

10

12

16

20

24

30

36 r

ANSI Class 300 600--~------------------------i

900__________----__------__------i 1500

-------------------------------~ Flange Raised Face (RF) _________________-_------j

Ring Type Joint (RTJ)___---------__bull-_____Imiddot

Materials Standard ~----~~--~----~--------~~ Stainless Steel

DJplex --~--------------------------~----~ _________________________--____~__

Device Type

Electronics

Transducers

Meter Size (Inches)

Daniel Ultrasonic Model Number Selections ES-21055 RevW

SeniorSonic (4-Path) ---------------1 JuniorSonic (1~Path) ------------1 JuniorSonic (2-Path) ______________

Mark II UL 24VDC 4-20rlA 3NPT

Mark UL 24VDC 1middot5VDC 3NPT ---------------------1 Mark CENaEC 24V DC 4-20mA M20 --------------_--__1

Mark IICB-JELEC24VDC1-SVDCM20

Mark II ClNELEc 24VDC 4-20mA M20 Rerrote

Mark II CENELEC 24VDC 1-5VDCM20 Rerrote

MarkU UL 24VOC4-20mA 3NPT Rerrote_

Mark II U~ 24VDC l-SVPG 3NPT Rerrote

Mark IIIUL 34 NPT

Mark III UL 34NPT Rerrote

TmiddotSlo T-12

4

middot 6

Page 6

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Systems Daniel Measurement and Control is the industry leader in designing constructing and commissioning of complex oil and gas metering systems to exacting standards

This global organization offers decades of petroleum fiscal flow measurement application experience Customers rely confidently on Daniels Systems Group international fabrication facilities customized engineering and its successes in field-testing and support From the simplest single-stream skid to complex on-site installations Daniel Systems delivers both natural gas and liquid petroleum tumkey applications Daniel Systems designs constructs and commissions the metering project blending up-toshythe-minute technology with decades of understanding what customers need and expect

Components of a Daniel Systems installation typically include meters valves provers flow-control instruments instrumentation and read-out equipment and process management components

Computer software and hardware are integrated with the measurement system Standard calculation methods include AGA3 (now API-MPMS-143) ISO 5167 AGA578 AGA9 and the API Manual for Petroleum Measurement Standards

Daniel DMSS-2000 Supervisory Control Systems utilize a sophisticated Graphical User Interface database server and a dedicated PLC for the metering skidMOV interface Redundancy is often used for custody transfer systems andor when system integrity is essential

A dedicated Project Manager and Project Team are assigned to each measurement system project This team is responsible for overall system design and project construction from start to finish A separate internal QAQC group reviews all design detailS inside and outside fabrication assembly and system testing

Whether it is a pipeline offshore production facility or a loading facility for ocean-going tankers the Daniel Systems group is a proven single-source solution for customers throughout the world

Page 7

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Daniel Measurement Services Daniel Measurement Services takes pride in being there after needs arise with the right solution for customers with gas and liquid fiscal flow measurement applications

Around the clock and around the world Daniel Measurement Services has experienced highly qualified people prepared to help customers who need assistance with the following

middot Start-up and commissioning middot Preventive maintenance middot Product repair I upgrades middot Project management and integration middot Meter Tube inspection and recertification middot Remote diagnostics middot Warranty Plus middot Technical training

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880

Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337

Stirling Scotland - UK Middle East amp Africa T +4401786433400 F +44 01786433401

Singapore - Asia Pacific T +65-6777-8211 F +65-6770-8001

USA Toll Free 1-888-FLOW-001 wwwdanielcom

Daniel is a whOlly owned subsidiary of Emerson Electric Co and a division of Emerson Process Management The Daniel logo is a registered trademark of Daniel Industnes tnc The Emerson logo is a trademark and service mark of Emerson Electric Co Brand mark listing are marks of one of the Emerson Process Management family of companies All other marks are property of their respecl ive owners The Daniel UltraSonic Gas Flow Meter including Mark III electronics is covered by US Patents 598330 and 4646 575 and patents pending The contents of this publication are presented for information purposes only and while effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or thel( use or applicability Daniel does not assume responsibility for the selection use or maintenance of any Daniel product Responsibility for proper selection use and maintenance of any Daniel product remains solely wilh the purchaser and end-userAII sales are governed by our terms and conditions which are available upon request We reserve the right to modify or improve the designs or specification of our products at any time without notice

-- -~J ~~--------- EMERSON bull ~ I

copy2004 Daniel Measurement and Control Inc All rights reserved Printed in the USA DAN -GFM-DS-0221-rev0404

reg DAN-3MT-3M-0801 -~I August 2001_-shy

3 SectioQltandProfiler Meter Tubes ~ Pf~6 5 ~~ IrMimiddot~

Instruments You Can Trust Daniel Meter Tubes are more than just fabricated pipe with an orifice fitting They are accurate dependable instruments because of Daniels dedicated approach to quality Extra steps taken during every phase of meter tube design and production separate Daniel Meter Tubes from all the rest

The Daniel 3 section meter tube is available with any style Senior or Junior orifice fitting Simplex plate holder or orifice flanges The assembly contains an inlet spool of the minimum length prescribed by the 143 standard The second section begins with a concentric flange mounted tube bund=1 leetln9 the 2000 API 143 requirements and a W thick spacer plate to ease tube removal for inspection The 04~r end of section 2 conshytains the orifice flange or fitting The third or downstream section follows and contains 2 branchOonnections and is extra long to allow for the addition of extra branch conshynections in the field If desired The standard meter tube has flanged outer ends Other end connections are avaUable on request

Inspectionffesting= Daniel maintains rigid inspection procedures during manufacturing of meter tubes Micrometer and internal surface roughness readings are recorded and supplied with each meter tUbe Customer or third party inspectors are welcome to verify these readings Radiography of welds is another service that is available

Fabrication Fabrication of your instrument Includes attaching the orifice fitting to the meter tube to make an integral primary measuring element For welding operashytions Daniel uses automatic welding machines and rotatshying positioners Highly skilled code qualified welders are employed to tum out highest quality on each job Special internal jigs and fixtures are used to insure smooth Inlet and outlet surfaces without steps or offsets All welds receive expert grinding by experienced craftsshy

men X

cl

-

gt shy

~

-

J ~

Features bull Dowel pin alignment close tolerance maleffemale

flange or knock out dowel pins insure that the bores of sections two and three are matched without offsets

One 1h and one 0 branch connection on the downstream for thermowell or other uses standard

Beveled flanged or reduced ends as well as any available weld fitting can be furnished on the ends of the tubes

Hydrostatically tested after manufacture

Each orifice fitting is tested for tap hole and orifice plate seal integrity after the meter tube has been pressure tested

Material Selection Daniel uses special cold drawn seamless tubing or honed pipe in the fabrication of meter tubes The strict reqUirements for intemal roundshyness and surface finish preclude the use of standard commercial pipe in most cases Daniel maintains a large inventory of this special pipe to rapidly complete your order

LT

EMERSON~ ltocess Management

~~------------------------------------------------------------~------------------------------

Raised Face Weld neck

NA

3M-30RW

3M-60RW High Pressure

3M-90RW 3M-150RW 3M-250RW

DAN-3MT-3M-0801 August 2001

3 Section Meter Tube Catalog Numbers 2-12 with Senior Fitting 10 amp 12 with Junior Fittina

~

Pressure Rating

150

Flange by Weld

(Flangnek)

3M-011

Flange by Flange

(Flanged)

3M-101

Weld by Weld

(Weldnek)

NA

Flange by Weld

(Flangnek)

3M-021

Flange by Flange

(Flanged)

3M-201

Weld by Weld

(Weldnek)

NA

300 3M-013 3M-103 NA 3M-023 3M-203 NA

600 3M-015 3M-105 3M-185 3M-025 3M-205 3M-285

H~h Pressure 3 Section Meter Tubes 900 3M-016 3M-106 3M-186 3M-026 3M-206 3M-286

1500 3M-017 3M-107 3M-187 3M-027 3M-207 3M-287

2500 3M-018 3M-108 3M-188 3M-028 3M-208 3M-288

2middot8 with Simplex 2middot12 with Orifice Flanges Flange byPressure

WeldRating Weld by Weld (Flangnek) (Weldnek)

150 3M-071 NA 3M-073300 NA

600 3M-075 3M-705 High Pressure

3M-7063M-076900 3M-7071500 3M-077 3M-7083M-0782500 -

Two Section Meter Tubes When Usmg Weldnek Flttmgs

Senior and Simplex fittings are also available in 10000 psi rating in some sizes All units are also available with Ring Type Joint (RTJ) flanges on request Sizes larger than 12 available on request

PackingShipping Daniel bolts together all meter A SPECIAL NOTE The use of factory original Daniel tubes when size permits before shipment This saves parts will assure your Senior Junior and Simplex Orifice the user time and field labor costs Fittings are protectshy fittings will stay within original specifications and operate ed by heavy lumber and the tube flanges by special-cut properly protectors

PaintingCoating The Daniel standard paint is a basic enamel type Special coatings such as multi-coat

offshore systems are available on request

3~Section Meter Tube with Tube Bundle

~-----~ U ----~---------~=~~middotmiddotmiddotmiddot~middot t)middotmiddot-middot ~- - -0bull )00)00 1

I~IC--middotmiddotmiddot-middot -----shyshy-bullmiddotV ------- ~

~ - ~-

~

ii~pound bullbullbull ~

Standard lenAths Size un Upstream 0 Downstream V (vane location)

3 7-5 4-0 130 4 9~~9 4-0 130

6 14-8 5-0 t30

102410 60middot middot 130 1~ +1 2tYS Tq 130 JiIf

Note Straightening vanes are not available in 2line size (See Dald Profller DAN-1852middot 2M)

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Daniel meter tubes can be supshyplied in many combinations and configurations Any of the orifice fittings plate holders or orifice flanges can be included in a meter tube Each 3 section standard meter tube is equipped with a flange mounted tube bundle straightener In accordance with April 2000 API 143 and a 1h thick spacer to facilitate tube removal for inspection Downstreams are longer than minimum required to allow for field Installation of additional branch connections If required

To specify a 3 section meter tube use the designation 3M followed by the type orifice holding deVice Ex 4 600 3 section meter tube with flanged ends using a Senior fitting flangneck style is specified as 4-3M-015 The same unit with a weldneck style Simplex is specified as 4middot3M-705 When ordering specify pipe schedule and end configuration Larger size and custom meter tube designs are available on request

The Daniel Profilertrade three section meter tube is availshy lows and contains 2 branch connections Other or addi able with any style Senior or Junior orifice fitting Simplex tiona I connections can be supplied in this section on plate holder or orifice flanges The assembly contains an request These meter tubes are for use in any piping conshyinlet spool of tile minimum length determined during testshy figuration with beta ratios to 67 Downstream sections ing to the API 143 standard The flange union between are extra long to allow for the addition of extra branch the first and second sections contains the ProfilerN and connections in the field if desired The standard meter a Y2 thick spacer plate to facilitate tube removal for tube has beveled outer ends Flanges or other end conshyinspection The outer end of section 2 contains the orishy nections are available on request fice flange or fitting The third or downstream section fol

Meter Tubes Catalog Numbers - 2 WI emor In9 bull Wit un or Itt ng2 1 th S Fitt 10 amp 12 h J i F i

Pressure Rating

Flange by Weld

(F1angnek)

Flange by Flange

(Flanged)

Weld by Weld

(Weldnek)

Flange by Weld

(Flangnek)

Flange by Flange

(Flanged)

Weld by Weld

(WeJdnek) 150 M011 M-101 NA M-021 M-201 NA 300 M-Q13 M-103 NA M023 M-203

NA 600 M-015 M-105 M-t85 M-025 M-205 M-285

2middot8 with Simplex 2middot12 with Orifice Flanges

Pressure Rating

Flange by Weld

weld by Weld

(Weldnek)CFlananekl 150 M-071 NA 300 M-073 NJA 6QfJ M-()75 M-705

Raised Face Weld Neck

NA - -

lM-30RW M-60RW

Two Section Meter Tube When USing Weldnek Fittings

Consult Factory for High Pressure Applications

PROFILERTM Flow Conditioning Plate

The Profiler has been tested and Shown to be in full compliance with the requirementS of API 143 April 2000 The Profiler both removes swirl

the tube bundle Available In flange mounted model only Also available In RTJ style on request

and creates a fully developed flow profile at the orifice Use of this unit allows shortened upstream straight pipe lengths of 17 diameters Beta ratio limit is 67 as with

-~---

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 7: Medidor de Flujo

I bull

CONFIGURAIiON SHEET MODEL NUMBER CONFIGURATION VW(H)

Pipe Size Materialsj Schedule FittingsEnd Connections

VW Q A 10OA S304V2 JLj CL 600 RF WN LtJ NPT

OB L S304L B 20 17 CL 900 RF WN S Socket 01 1 A S316L C Bored

Scvcmllypcs of ICS Tube amp Flanges 0 StdOC 1V2 ~ fittings aV01ilablc

2 40 00

S304 Cone Support amp Couplings E02 Epoxy Coated Blue (excluding cone) F 80

03 2V2 3 r-u CS Tube amp Flanges J 100

04 4 S304 Cone Support amp Couplings 120K jOther materials can include6 Coating Painting Per Customer Req 14006 L

-shy HASTELLOY C-276 S321H8 G 160 DUPLEX 2205 INCONEL 625

08 10 XXS

CHROMEMOLY P22PII 10 H

10S MONEL K400K500

12 M12 14 P XS

CARBON STEELS 14

16 -- shy

A350 A333 AP15L A 106B 16

18 20 18

20 24~

Example VW10AE16N V-Cone 10 inch line size S316L schedule 40 pipe ANSI CL 600 RF WN flanges V2NPT fittings

Type

STANDARD PIPE SCHEDUIpoundS Stainless Steel Carbon Steel

Size Std Size Std to 4 C

6 to 10 E 12 and up 0

6 to 16 18 and up

E 0

Pipe up to 8 utilizes seamless pipe Above 8 is welded pipe

ABBREVIATIONS ASME American Society of Mechanical Engineers NPT National pipe taper SS Stainless steel RF Raised Face CS Carbon steel WN Weld Neck

Technical questions can be answered through a local representative or through our application engineers

REPRESENTED BY

MANUFACTURING STANDARDS McCrometers welders and welding procedures are qualified in accordance with ASME Section IX All meters are visually inspected for weld defects Specific customer requirements can be complied with upon request

The welding can be in accordance with

bull ASME Section VIII

bull ASME B311

bull ASMEB313

Non-destmctive testing can include

bull Hydrostatic Pressure Testing

bull Penetrant Examination

bull Radiographic Examination

bull Positive Material Inspection

bull Magnetic Particle Examination

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-6811 Fax (909) 652-3078 Web Site httpwwwmccromelercom e-mail infomccrometercom

Lit24509-36 Rev 146-00 copy 2000 by McCrometer IncPrinted in USA

~----------------------~---------------------------------------------------------------------------

V -Cone Installation Guide Upstream and Downstream Minimum Straight Pipe Run Requirements

For Liquid Metering and Gases at a Reynolds Number (Re) Value Less Than or Equal To 200000

For fl greater than or equal to 065 add ID

Obstruction DownSize Range Up Stream Stream

I Elbow OD

2 Elbows

OD

OD OD

Tees OD OD Not Preferred ValveAll Sizes Butterfly Valve (control valve) DownstreamPosition

3D 3D

Butterfly Valve (shutoff valve) 3D OD

Full port Ballvalve (shutoff) OD OD

Heat Exchanger (Depends on Type) OD OD

Expander (067D to D) over a length ID ID of 2SD

Reducer (3D to D) over a length of ID ID 3SD

Note The meter and adjoining pipe should have equal IDs

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-6811 Fax (909) 652-3078 ~ MCOOMEIER Web Site http wwwmccrometercom e-mail infomccrometercom

Lit24S09-21 Rev 10102-04 copy2004 by McCrometer InclPrinted in USA

Product Data Sheet DAN-GFM-DS -21-rev0404 ( )

April2004 SeniorSonic with Mark TM Electronics

- SeniorSonic The Daniel SeniorSonic Gas Flow Meter with Mark IWM Electronics saves you time and money Lost and unaccounted for gas is reduced by exceptional low and high flow accuracy and linearity throughout the calibrated flow range Time is saved by a best-in-class audit trail Mark III Electronics can pinpoint alarms events and configuration changes in a matter of seconds Best of all operating the Daniel SeniorSonic gas flow meter is easy with the Windowsreg based Daniel Customer User Interface (CUI) software

Features middot Excellent long-term performance

Velocity Range Most sizes are rated to performa at 100 fps middot Full electronic audit trail (exceeds API 211) Over-range of up to 125 fps and in some cases beyond 125 middot Exceptional low and high flow performance

middot Bi-directional multi-point calibration coefficients fps in emergencymiddot situations and without transducer failure

middot Rangeability exceeds 50 1 with calibration Availability is limited by line size and ANSI rating Visit middot ANSI 30060090015002500 versions wwwdanielcomseniorsonic for additional information middot Extractable transducers (For all sizes) middot Minimum upstream piping requirements Meter specifications

Gas temperature -4 to +212deg F (-20 to +100deg C) Easy to learn and use CUI software features Operating pressure range 150 - 3750 psig middot Comprehensive monitor screen (1030 - 25855 kPa) Consult factory for lower and middot Field start-up wizard higher pressure applications middot Calibration wizards (analog and frequency) Flanges RF for 3001500 RTJ for 6002500 middot Flow calibration configuration wizard middot Audit 1 alarm 1history retrieval Power DC version - 1224 (11-36) VDC 6 watts maximum middot Digital waveform viewing middot Maintenance log summary in ExcelI Environmental middot Built-in AGA 10 SOS calculator Operating temperature -40 to +149deg F (-40 to +65deg C) middot Automatic file naming Operating relative humidity up to 95 non-condensing middot Trending of maintenance logs Storage temperature -40 to +185 0 F (-40 to +85 0 C) middot Configuration comparison with exception summary middot Remote dial-up support and Ethernet support Typical Applications middot Unlimited meter directory support middot Custody transfer

middot Power plants Specifications middot Large industrial users

Electronic unit middot City gates Communication protocol Modbus RTUASCII amp TCPIIP middot Production Two serial RS-232485 ports and Ethernet middot Underground storage sites Communication speed Up to 115 KBPS middot Offshore Frequency outputs Four Frequency range 0-10005000 Hz Safety classifications Digital output Selectable (up to four for data valid or flow UL listed for use in Class I Division 1 Group D hazardous

direction) locations in both the US and Canada (UL E152246) Calculation update time Configurable for 14 and 1 second CE marked to ATEX directive (949EC ) (pending)

Certified to Eex d ia liB T4 to standards EN 50014 EN 50018 Accuracy and EN 50020 (pending) Flow calibrated accuracy plusmn 01 (Relative to lab) Absolute accuracy Including lab uncertainty about 03 Repeatability plusmn 02 of reading for Ot to Omax

-- - tI II~ EMERSON ~-----

wwwdanielcom

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Recommended Ma~jum Flow Velocity Meter Size J Meter Size Metric Max Inches Max ftI~ m tris

4 100 100 30 6 100 150 30 8 100 200 30

10 80 250 24 12 80 300 24 16 85 400 26 20 85 500 26 24 85 600 26 30 70 750 21 36 70 900 21

Dimensions These measurements are meant only as an aid in the design of metering systems Consult Daniel engineering drawings prior to construction

Typical 600 ANSI Meter with 45 Degree-Angled Transducers Overall End- Flange Approximate Overall End- Flange Approximate

Meter Size To-End Diameter Weight To-End Diameter Weight (Inches) (Inches) (Inches) (Pounds) (Millimeters) (Millimeters) (Kilograms)

4 2900 1075 370 737 273 168 6 2950 1400 460 749 356 209

8 3150 1650 650 800 419 295 10 3400 2000 885 864 508 402 12 3544 2200 1075 900 559 489 16 4400 2700 1955 1118 686 889 18 4531 2925 2800 11sect1 743 1273 20 5062 3200 30Z5 12amp6 84~ 1398

0 4 5862 3700 404~ 1489 940 1839 30 6700 4450 4925 1702 1130 2239 36 7350 5175 6425 1867 1314 2920

()l p l ( C flO

bull I iY0

e

Page 2

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 60 F and gas composition These values are intended to be a guide in Contact Daniel engineering for a specific application

_ Flow Rates (JIISCFHl Basea Upon 100 ftls PSIG 4 6 8 10 12 16 20 24 30 36 100 247 561 971 1532 2174 3432 5398 7807 12607 18154 200 468 1065 1845 2908 4127 6515 10248 14822 23935 34467 300 696 1584 2743 4325 6137 9690 15240 22043 35596 51258 400 931 2118 3668 5782 8206 12955 20377 29472 47593 68534 500 2667 4619 7282 10334 16315 25661 37114 59934 86305 600 1421 3232 5597 8823 12522 19770 31095 44973 72626 104582 700 1676 3813 6602 10409 14772 23322 36682 53055 85677 123374 800 1938 4409 7635 12036 17082 26968 42417 61349 99070 142661 900 2207 5021 8694 13706 19452 30710 48302 69861 112816 162455 1000 2482 5646 9777 15414 21875 34536 54320 78565 126872 182696 1100 2763 6286 10885 17161 24355 38451 60478 87471 141254 203405 1200 3050 6939 12015 18943 26883 42443 66756 96551 155917 224521 1300 3341 7602 13164 20753 29453 46500 73137 105781 170822 245983 1400 3637 8274 14327 22587 32055 50608 79599 115127 185915 267718 1500 3935 8953 15504 24442 34688 54765 86137 124583 201184 289706 1600 4235 9635 16685 26305 37331 58938 92700 134076 216515 311781 1700 4536 10321 17871 28175 39986 63128 99291 143608 231908 333948 1800 4836 11002 19052 30036 42627 67298 105850 153094 247227 356006 1900 5134 11681 20226 31888 45255 71448 112376 162534 262471 377958 2000 5429 12350 21386 33716 47849 75543 118818 171851 277516 399623

Flow Rates (MIfIISCFfJ) Based Upon 100 ffls PSIG 4 6 8 10 12 16 20 24 30 36 100 59 135 233 368 522 824 1295 1874 3026 4357 200 113 256 443 698 990 1564 2459 3557 5744 8272 300 168 380 658 1038 1473 2326 3658 5290 8543 1230 400 224 508 880 1388 1969 3109 4890 7073 1142 1645 600 282 640 110~ 1748 2480 3916 6159 8907 1438 2071 600 342 776 1343 2118 3005 4745 7463 1079 1743 2510 700 403 915 1685 2498 3545 5597 8804 1273 2066 2961 800 466 1058 1832 2889 4100 6472 1018 1472 2378 3424 900 531 1205 2087 3289 4668 7370 1159 1677 2708 3899

1000 597 1355 2346 3699 5250 8289 1304 1886 3045 4385 1100 665 1509 2612 4119 5845 9228 1451 2099 3390 4882 1200 734 1665 2884 4546 6452 1019 1602 2317 3742 5389 1300 804 1824 3159 4981 7069 1116 1755 2539 4100 5904 1400 875 1986 3438 5421 7693 1215 1910 2763 4462 6425 1500 947 2149 3721 5866 8325 1314 2067 2990 4828 6953 1600 1019 2313 4004 6313 8960 1415 2225 3218 5196 7483 1700 1091 2477 4289 6762 9597 1515 2383 3447 5566middot 8015 1800 1164 2641 4572 7209 1023 1615 2540 3674 5933 8544 1900 1235 2803 4854 7653 1086 1715 2697 3901 6299 9071 2000 1306 2964 5133 8092 1148 1813 2852 4124 6660 9591

Calculating meter capacity To calculate a volume rate for a given velocity multiply the capacity in this table by the desired at the pressure and divide the answer by 100 Example Determine the hourly flow rate al 70 fps for an 8 inch meter operating at 800 psig Volume =7635 MSCFH Velocity 70 Answer = 763570100 = 5344 MSCFH

Pa~e 3

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 20 F and gas composition These values are intended to be a guide In Contact Daniel nee ring for a application

Flow RateS (IASOFH) Based UppJ1 30 mls Schedule 40) kPag 4 6 8 10 12 16 20 24 30 36 1000 967 2201 3811 6007 8527 1346 2117 3062 4945 7121 1500 1422 3234 5600 8827 1253 1978 3111 4500 7267 1046 2000 1885 4289 7428 1171 1662 2624 4127 5969 9639 1388 2500 2359 5367 9294 1465 2079 3283 5164 7469 1206 1737 3000 2843 6468 1120 1765 2506 3956 6223 9000 1453 2093 3500 3337 7592 1315 2072 2941 4644 7304 1056 1706 2457 4000 3841 8739 1513 2385 3386 5346 8408 1216 1964 2828 4500 4356 9910 171S 2705 3840 6062 9535 1379 2227 3207 5000 4881 1111 1923 3031 4303 6793 1068 1546 2495 3593 5500 5417 1232 2134 3364 4774 7538 1186 1715 2769 3987 6000 5962 1 3702 5255 8297 1305 1887 3048 4389 6500 6517 1483 2568 4047 5745 9070 1427 2063 3332 4798 7000 7082 1611 2790 4398 6243 9856 1550 2242 3621 5214 7500 7656 1742 3016 4754 6748 1065 1676 2424 3914 5636 8000 8238 1874 3246 5116 7262 1146 1803 2608 4212 6065 8500 8828 2009 3478 5482 7782 1229 1932 2795 4513 6499 9000 9425 2144 3713 5853 8308 1312 2063 2984 4818 6939 9500 10028 2281 3951 6227 8839 1396 2195 3175 5127 7382

10000 10636 2420 4190 6604 9375 1480 2328 3367 5437 7830

Flow Rates (IANSOND) Based Upon 30 mls (Scnedule 40) PSIG 4 6 8 10 12 16 20 24 30 36 1000 0232 0528 0915 1442 2046 3231 5082 7350 11869 17091 1500 0341 0776 1344 2119 3007 4748 7468 10801 17441 25116 2000 0453 1029 1783 2810 3989 6297 9904 14325 23133 33311 2500 0566 1288 2231 3516 4991 7879 12393 17924 28946 41682 3000 0682 1552 2688 4237 6014 9495 14935 21600 34882 50230 3500 0801 1821 3155 4973 7059 11145 17530 25354 40943 58958 4000 0922 2097 3632 5725 8126 12830 20179 29186 47131 67869 4500 1045 2378 4119 6492 9215 14549 22883 33097 53447 76963 5000 1171 2664 4615 7275 10326 16302 25641 37086 59889 86240 5500 1300 2957 5121 8072 11459 18091 28454 41154 66458 95699 6000 1431 3254 5637 8885 19912 31319 45298 73150 105336 6500 1564 3557 6162 9713 13787 21767 34236 49517 79964 115148 7000 1700 3866 6696 10555 14982 23653 37203 53808 86893 125126 7500 1837 4179 7239 11410 16196 25570 40218 58168 93934 135265 8000 1977 4497 7789 12278 17428 27515 43277 62592 101078 145553 8500 2119 4819 8347 13157 18676 29485 46376 67075 108318 155978 9000 2262 51 8912 14047 19939 31479 71611 115642 166524 9500 2407 5474 9482 14945 21214 33492 52679 76191 123038 177175

10000 2553 5805 10056 15851 22500 35522 55871 80808 130494 187911

Calculating meter capacity To calculate a volume rate for a given velocity the capacity this table by the desired velocity at the operating pressure and divide the answer 100 Determine the hourly flow rate at 30 mps for an 8 inch meter at 4500 Volume 1716 Velocity 10 Answer 17161030 5719 MSCMH

Product Oata Sheet DAN-GFM-DS-21-rev0404 April 2004

The drawings below represent recommended piping lengths for various flow conditioners when installed with the Daniel SeniorSonic flowmeter If shorter lengths are used there may be an increase in flow measurement uncertainty

Piping Recommendation For SeniorSonic With No Flow Conditioner

1~~--------------------200 -----------------------~

Q----I__------shy~

J ~~f --M-I-middotn-im-~-~-p-iP-i-n-g-R-e-c-o-m-m-e-n-a-a-tl-o-n-F-o-r-S-en-I-o-r-S-o-n-ic-W-it-h-D-a-n-ie-l-p-r-O-fi-le-r-o-r-C-p-~-5-0-E~-F--o-w-c-o-n-d-itl-io-n-e-r--

1 00 middot -2 o~o ~1gt

[ _____ ---Al11~ ----- =ul [II I

I 0 0 a It Minimum Piping Recommendation for Bimiddotdirectional SeniorSonic

with Daniel Profiler or CPA 50E Flow Conditioner

~------- 100 ------t ~------- 100 ----~ - 50---shy

3middot 50

-- 50 ---shy

3middot 50

~ -

A WARNING Do not operate this instrument in excess of the specifications listed Failure to heed this warning could result in serious injury andor damage to the equipment

Page 5

---- - --- _ --- ----------------- -------------------------shy

--iI

-------~~--------1

----~----------------I _____________________I

----~------~----__i _____bullmiddot________ ----__i

____________shy____~__i

____________________---i __________________

_________shy__________~~

~ I ~

I

~

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

8

10

12

16

20

24

30

36 r

ANSI Class 300 600--~------------------------i

900__________----__------__------i 1500

-------------------------------~ Flange Raised Face (RF) _________________-_------j

Ring Type Joint (RTJ)___---------__bull-_____Imiddot

Materials Standard ~----~~--~----~--------~~ Stainless Steel

DJplex --~--------------------------~----~ _________________________--____~__

Device Type

Electronics

Transducers

Meter Size (Inches)

Daniel Ultrasonic Model Number Selections ES-21055 RevW

SeniorSonic (4-Path) ---------------1 JuniorSonic (1~Path) ------------1 JuniorSonic (2-Path) ______________

Mark II UL 24VDC 4-20rlA 3NPT

Mark UL 24VDC 1middot5VDC 3NPT ---------------------1 Mark CENaEC 24V DC 4-20mA M20 --------------_--__1

Mark IICB-JELEC24VDC1-SVDCM20

Mark II ClNELEc 24VDC 4-20mA M20 Rerrote

Mark II CENELEC 24VDC 1-5VDCM20 Rerrote

MarkU UL 24VOC4-20mA 3NPT Rerrote_

Mark II U~ 24VDC l-SVPG 3NPT Rerrote

Mark IIIUL 34 NPT

Mark III UL 34NPT Rerrote

TmiddotSlo T-12

4

middot 6

Page 6

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Systems Daniel Measurement and Control is the industry leader in designing constructing and commissioning of complex oil and gas metering systems to exacting standards

This global organization offers decades of petroleum fiscal flow measurement application experience Customers rely confidently on Daniels Systems Group international fabrication facilities customized engineering and its successes in field-testing and support From the simplest single-stream skid to complex on-site installations Daniel Systems delivers both natural gas and liquid petroleum tumkey applications Daniel Systems designs constructs and commissions the metering project blending up-toshythe-minute technology with decades of understanding what customers need and expect

Components of a Daniel Systems installation typically include meters valves provers flow-control instruments instrumentation and read-out equipment and process management components

Computer software and hardware are integrated with the measurement system Standard calculation methods include AGA3 (now API-MPMS-143) ISO 5167 AGA578 AGA9 and the API Manual for Petroleum Measurement Standards

Daniel DMSS-2000 Supervisory Control Systems utilize a sophisticated Graphical User Interface database server and a dedicated PLC for the metering skidMOV interface Redundancy is often used for custody transfer systems andor when system integrity is essential

A dedicated Project Manager and Project Team are assigned to each measurement system project This team is responsible for overall system design and project construction from start to finish A separate internal QAQC group reviews all design detailS inside and outside fabrication assembly and system testing

Whether it is a pipeline offshore production facility or a loading facility for ocean-going tankers the Daniel Systems group is a proven single-source solution for customers throughout the world

Page 7

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Daniel Measurement Services Daniel Measurement Services takes pride in being there after needs arise with the right solution for customers with gas and liquid fiscal flow measurement applications

Around the clock and around the world Daniel Measurement Services has experienced highly qualified people prepared to help customers who need assistance with the following

middot Start-up and commissioning middot Preventive maintenance middot Product repair I upgrades middot Project management and integration middot Meter Tube inspection and recertification middot Remote diagnostics middot Warranty Plus middot Technical training

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880

Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337

Stirling Scotland - UK Middle East amp Africa T +4401786433400 F +44 01786433401

Singapore - Asia Pacific T +65-6777-8211 F +65-6770-8001

USA Toll Free 1-888-FLOW-001 wwwdanielcom

Daniel is a whOlly owned subsidiary of Emerson Electric Co and a division of Emerson Process Management The Daniel logo is a registered trademark of Daniel Industnes tnc The Emerson logo is a trademark and service mark of Emerson Electric Co Brand mark listing are marks of one of the Emerson Process Management family of companies All other marks are property of their respecl ive owners The Daniel UltraSonic Gas Flow Meter including Mark III electronics is covered by US Patents 598330 and 4646 575 and patents pending The contents of this publication are presented for information purposes only and while effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or thel( use or applicability Daniel does not assume responsibility for the selection use or maintenance of any Daniel product Responsibility for proper selection use and maintenance of any Daniel product remains solely wilh the purchaser and end-userAII sales are governed by our terms and conditions which are available upon request We reserve the right to modify or improve the designs or specification of our products at any time without notice

-- -~J ~~--------- EMERSON bull ~ I

copy2004 Daniel Measurement and Control Inc All rights reserved Printed in the USA DAN -GFM-DS-0221-rev0404

reg DAN-3MT-3M-0801 -~I August 2001_-shy

3 SectioQltandProfiler Meter Tubes ~ Pf~6 5 ~~ IrMimiddot~

Instruments You Can Trust Daniel Meter Tubes are more than just fabricated pipe with an orifice fitting They are accurate dependable instruments because of Daniels dedicated approach to quality Extra steps taken during every phase of meter tube design and production separate Daniel Meter Tubes from all the rest

The Daniel 3 section meter tube is available with any style Senior or Junior orifice fitting Simplex plate holder or orifice flanges The assembly contains an inlet spool of the minimum length prescribed by the 143 standard The second section begins with a concentric flange mounted tube bund=1 leetln9 the 2000 API 143 requirements and a W thick spacer plate to ease tube removal for inspection The 04~r end of section 2 conshytains the orifice flange or fitting The third or downstream section follows and contains 2 branchOonnections and is extra long to allow for the addition of extra branch conshynections in the field If desired The standard meter tube has flanged outer ends Other end connections are avaUable on request

Inspectionffesting= Daniel maintains rigid inspection procedures during manufacturing of meter tubes Micrometer and internal surface roughness readings are recorded and supplied with each meter tUbe Customer or third party inspectors are welcome to verify these readings Radiography of welds is another service that is available

Fabrication Fabrication of your instrument Includes attaching the orifice fitting to the meter tube to make an integral primary measuring element For welding operashytions Daniel uses automatic welding machines and rotatshying positioners Highly skilled code qualified welders are employed to tum out highest quality on each job Special internal jigs and fixtures are used to insure smooth Inlet and outlet surfaces without steps or offsets All welds receive expert grinding by experienced craftsshy

men X

cl

-

gt shy

~

-

J ~

Features bull Dowel pin alignment close tolerance maleffemale

flange or knock out dowel pins insure that the bores of sections two and three are matched without offsets

One 1h and one 0 branch connection on the downstream for thermowell or other uses standard

Beveled flanged or reduced ends as well as any available weld fitting can be furnished on the ends of the tubes

Hydrostatically tested after manufacture

Each orifice fitting is tested for tap hole and orifice plate seal integrity after the meter tube has been pressure tested

Material Selection Daniel uses special cold drawn seamless tubing or honed pipe in the fabrication of meter tubes The strict reqUirements for intemal roundshyness and surface finish preclude the use of standard commercial pipe in most cases Daniel maintains a large inventory of this special pipe to rapidly complete your order

LT

EMERSON~ ltocess Management

~~------------------------------------------------------------~------------------------------

Raised Face Weld neck

NA

3M-30RW

3M-60RW High Pressure

3M-90RW 3M-150RW 3M-250RW

DAN-3MT-3M-0801 August 2001

3 Section Meter Tube Catalog Numbers 2-12 with Senior Fitting 10 amp 12 with Junior Fittina

~

Pressure Rating

150

Flange by Weld

(Flangnek)

3M-011

Flange by Flange

(Flanged)

3M-101

Weld by Weld

(Weldnek)

NA

Flange by Weld

(Flangnek)

3M-021

Flange by Flange

(Flanged)

3M-201

Weld by Weld

(Weldnek)

NA

300 3M-013 3M-103 NA 3M-023 3M-203 NA

600 3M-015 3M-105 3M-185 3M-025 3M-205 3M-285

H~h Pressure 3 Section Meter Tubes 900 3M-016 3M-106 3M-186 3M-026 3M-206 3M-286

1500 3M-017 3M-107 3M-187 3M-027 3M-207 3M-287

2500 3M-018 3M-108 3M-188 3M-028 3M-208 3M-288

2middot8 with Simplex 2middot12 with Orifice Flanges Flange byPressure

WeldRating Weld by Weld (Flangnek) (Weldnek)

150 3M-071 NA 3M-073300 NA

600 3M-075 3M-705 High Pressure

3M-7063M-076900 3M-7071500 3M-077 3M-7083M-0782500 -

Two Section Meter Tubes When Usmg Weldnek Flttmgs

Senior and Simplex fittings are also available in 10000 psi rating in some sizes All units are also available with Ring Type Joint (RTJ) flanges on request Sizes larger than 12 available on request

PackingShipping Daniel bolts together all meter A SPECIAL NOTE The use of factory original Daniel tubes when size permits before shipment This saves parts will assure your Senior Junior and Simplex Orifice the user time and field labor costs Fittings are protectshy fittings will stay within original specifications and operate ed by heavy lumber and the tube flanges by special-cut properly protectors

PaintingCoating The Daniel standard paint is a basic enamel type Special coatings such as multi-coat

offshore systems are available on request

3~Section Meter Tube with Tube Bundle

~-----~ U ----~---------~=~~middotmiddotmiddotmiddot~middot t)middotmiddot-middot ~- - -0bull )00)00 1

I~IC--middotmiddotmiddot-middot -----shyshy-bullmiddotV ------- ~

~ - ~-

~

ii~pound bullbullbull ~

Standard lenAths Size un Upstream 0 Downstream V (vane location)

3 7-5 4-0 130 4 9~~9 4-0 130

6 14-8 5-0 t30

102410 60middot middot 130 1~ +1 2tYS Tq 130 JiIf

Note Straightening vanes are not available in 2line size (See Dald Profller DAN-1852middot 2M)

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Daniel meter tubes can be supshyplied in many combinations and configurations Any of the orifice fittings plate holders or orifice flanges can be included in a meter tube Each 3 section standard meter tube is equipped with a flange mounted tube bundle straightener In accordance with April 2000 API 143 and a 1h thick spacer to facilitate tube removal for inspection Downstreams are longer than minimum required to allow for field Installation of additional branch connections If required

To specify a 3 section meter tube use the designation 3M followed by the type orifice holding deVice Ex 4 600 3 section meter tube with flanged ends using a Senior fitting flangneck style is specified as 4-3M-015 The same unit with a weldneck style Simplex is specified as 4middot3M-705 When ordering specify pipe schedule and end configuration Larger size and custom meter tube designs are available on request

The Daniel Profilertrade three section meter tube is availshy lows and contains 2 branch connections Other or addi able with any style Senior or Junior orifice fitting Simplex tiona I connections can be supplied in this section on plate holder or orifice flanges The assembly contains an request These meter tubes are for use in any piping conshyinlet spool of tile minimum length determined during testshy figuration with beta ratios to 67 Downstream sections ing to the API 143 standard The flange union between are extra long to allow for the addition of extra branch the first and second sections contains the ProfilerN and connections in the field if desired The standard meter a Y2 thick spacer plate to facilitate tube removal for tube has beveled outer ends Flanges or other end conshyinspection The outer end of section 2 contains the orishy nections are available on request fice flange or fitting The third or downstream section fol

Meter Tubes Catalog Numbers - 2 WI emor In9 bull Wit un or Itt ng2 1 th S Fitt 10 amp 12 h J i F i

Pressure Rating

Flange by Weld

(F1angnek)

Flange by Flange

(Flanged)

Weld by Weld

(Weldnek)

Flange by Weld

(Flangnek)

Flange by Flange

(Flanged)

Weld by Weld

(WeJdnek) 150 M011 M-101 NA M-021 M-201 NA 300 M-Q13 M-103 NA M023 M-203

NA 600 M-015 M-105 M-t85 M-025 M-205 M-285

2middot8 with Simplex 2middot12 with Orifice Flanges

Pressure Rating

Flange by Weld

weld by Weld

(Weldnek)CFlananekl 150 M-071 NA 300 M-073 NJA 6QfJ M-()75 M-705

Raised Face Weld Neck

NA - -

lM-30RW M-60RW

Two Section Meter Tube When USing Weldnek Fittings

Consult Factory for High Pressure Applications

PROFILERTM Flow Conditioning Plate

The Profiler has been tested and Shown to be in full compliance with the requirementS of API 143 April 2000 The Profiler both removes swirl

the tube bundle Available In flange mounted model only Also available In RTJ style on request

and creates a fully developed flow profile at the orifice Use of this unit allows shortened upstream straight pipe lengths of 17 diameters Beta ratio limit is 67 as with

-~---

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 8: Medidor de Flujo

V -Cone Installation Guide Upstream and Downstream Minimum Straight Pipe Run Requirements

For Liquid Metering and Gases at a Reynolds Number (Re) Value Less Than or Equal To 200000

For fl greater than or equal to 065 add ID

Obstruction DownSize Range Up Stream Stream

I Elbow OD

2 Elbows

OD

OD OD

Tees OD OD Not Preferred ValveAll Sizes Butterfly Valve (control valve) DownstreamPosition

3D 3D

Butterfly Valve (shutoff valve) 3D OD

Full port Ballvalve (shutoff) OD OD

Heat Exchanger (Depends on Type) OD OD

Expander (067D to D) over a length ID ID of 2SD

Reducer (3D to D) over a length of ID ID 3SD

Note The meter and adjoining pipe should have equal IDs

3255 W Stetson Ave Hemet CA 92545-7799 USA -- Phone (909) 652-6811 Fax (909) 652-3078 ~ MCOOMEIER Web Site http wwwmccrometercom e-mail infomccrometercom

Lit24S09-21 Rev 10102-04 copy2004 by McCrometer InclPrinted in USA

Product Data Sheet DAN-GFM-DS -21-rev0404 ( )

April2004 SeniorSonic with Mark TM Electronics

- SeniorSonic The Daniel SeniorSonic Gas Flow Meter with Mark IWM Electronics saves you time and money Lost and unaccounted for gas is reduced by exceptional low and high flow accuracy and linearity throughout the calibrated flow range Time is saved by a best-in-class audit trail Mark III Electronics can pinpoint alarms events and configuration changes in a matter of seconds Best of all operating the Daniel SeniorSonic gas flow meter is easy with the Windowsreg based Daniel Customer User Interface (CUI) software

Features middot Excellent long-term performance

Velocity Range Most sizes are rated to performa at 100 fps middot Full electronic audit trail (exceeds API 211) Over-range of up to 125 fps and in some cases beyond 125 middot Exceptional low and high flow performance

middot Bi-directional multi-point calibration coefficients fps in emergencymiddot situations and without transducer failure

middot Rangeability exceeds 50 1 with calibration Availability is limited by line size and ANSI rating Visit middot ANSI 30060090015002500 versions wwwdanielcomseniorsonic for additional information middot Extractable transducers (For all sizes) middot Minimum upstream piping requirements Meter specifications

Gas temperature -4 to +212deg F (-20 to +100deg C) Easy to learn and use CUI software features Operating pressure range 150 - 3750 psig middot Comprehensive monitor screen (1030 - 25855 kPa) Consult factory for lower and middot Field start-up wizard higher pressure applications middot Calibration wizards (analog and frequency) Flanges RF for 3001500 RTJ for 6002500 middot Flow calibration configuration wizard middot Audit 1 alarm 1history retrieval Power DC version - 1224 (11-36) VDC 6 watts maximum middot Digital waveform viewing middot Maintenance log summary in ExcelI Environmental middot Built-in AGA 10 SOS calculator Operating temperature -40 to +149deg F (-40 to +65deg C) middot Automatic file naming Operating relative humidity up to 95 non-condensing middot Trending of maintenance logs Storage temperature -40 to +185 0 F (-40 to +85 0 C) middot Configuration comparison with exception summary middot Remote dial-up support and Ethernet support Typical Applications middot Unlimited meter directory support middot Custody transfer

middot Power plants Specifications middot Large industrial users

Electronic unit middot City gates Communication protocol Modbus RTUASCII amp TCPIIP middot Production Two serial RS-232485 ports and Ethernet middot Underground storage sites Communication speed Up to 115 KBPS middot Offshore Frequency outputs Four Frequency range 0-10005000 Hz Safety classifications Digital output Selectable (up to four for data valid or flow UL listed for use in Class I Division 1 Group D hazardous

direction) locations in both the US and Canada (UL E152246) Calculation update time Configurable for 14 and 1 second CE marked to ATEX directive (949EC ) (pending)

Certified to Eex d ia liB T4 to standards EN 50014 EN 50018 Accuracy and EN 50020 (pending) Flow calibrated accuracy plusmn 01 (Relative to lab) Absolute accuracy Including lab uncertainty about 03 Repeatability plusmn 02 of reading for Ot to Omax

-- - tI II~ EMERSON ~-----

wwwdanielcom

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Recommended Ma~jum Flow Velocity Meter Size J Meter Size Metric Max Inches Max ftI~ m tris

4 100 100 30 6 100 150 30 8 100 200 30

10 80 250 24 12 80 300 24 16 85 400 26 20 85 500 26 24 85 600 26 30 70 750 21 36 70 900 21

Dimensions These measurements are meant only as an aid in the design of metering systems Consult Daniel engineering drawings prior to construction

Typical 600 ANSI Meter with 45 Degree-Angled Transducers Overall End- Flange Approximate Overall End- Flange Approximate

Meter Size To-End Diameter Weight To-End Diameter Weight (Inches) (Inches) (Inches) (Pounds) (Millimeters) (Millimeters) (Kilograms)

4 2900 1075 370 737 273 168 6 2950 1400 460 749 356 209

8 3150 1650 650 800 419 295 10 3400 2000 885 864 508 402 12 3544 2200 1075 900 559 489 16 4400 2700 1955 1118 686 889 18 4531 2925 2800 11sect1 743 1273 20 5062 3200 30Z5 12amp6 84~ 1398

0 4 5862 3700 404~ 1489 940 1839 30 6700 4450 4925 1702 1130 2239 36 7350 5175 6425 1867 1314 2920

()l p l ( C flO

bull I iY0

e

Page 2

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 60 F and gas composition These values are intended to be a guide in Contact Daniel engineering for a specific application

_ Flow Rates (JIISCFHl Basea Upon 100 ftls PSIG 4 6 8 10 12 16 20 24 30 36 100 247 561 971 1532 2174 3432 5398 7807 12607 18154 200 468 1065 1845 2908 4127 6515 10248 14822 23935 34467 300 696 1584 2743 4325 6137 9690 15240 22043 35596 51258 400 931 2118 3668 5782 8206 12955 20377 29472 47593 68534 500 2667 4619 7282 10334 16315 25661 37114 59934 86305 600 1421 3232 5597 8823 12522 19770 31095 44973 72626 104582 700 1676 3813 6602 10409 14772 23322 36682 53055 85677 123374 800 1938 4409 7635 12036 17082 26968 42417 61349 99070 142661 900 2207 5021 8694 13706 19452 30710 48302 69861 112816 162455 1000 2482 5646 9777 15414 21875 34536 54320 78565 126872 182696 1100 2763 6286 10885 17161 24355 38451 60478 87471 141254 203405 1200 3050 6939 12015 18943 26883 42443 66756 96551 155917 224521 1300 3341 7602 13164 20753 29453 46500 73137 105781 170822 245983 1400 3637 8274 14327 22587 32055 50608 79599 115127 185915 267718 1500 3935 8953 15504 24442 34688 54765 86137 124583 201184 289706 1600 4235 9635 16685 26305 37331 58938 92700 134076 216515 311781 1700 4536 10321 17871 28175 39986 63128 99291 143608 231908 333948 1800 4836 11002 19052 30036 42627 67298 105850 153094 247227 356006 1900 5134 11681 20226 31888 45255 71448 112376 162534 262471 377958 2000 5429 12350 21386 33716 47849 75543 118818 171851 277516 399623

Flow Rates (MIfIISCFfJ) Based Upon 100 ffls PSIG 4 6 8 10 12 16 20 24 30 36 100 59 135 233 368 522 824 1295 1874 3026 4357 200 113 256 443 698 990 1564 2459 3557 5744 8272 300 168 380 658 1038 1473 2326 3658 5290 8543 1230 400 224 508 880 1388 1969 3109 4890 7073 1142 1645 600 282 640 110~ 1748 2480 3916 6159 8907 1438 2071 600 342 776 1343 2118 3005 4745 7463 1079 1743 2510 700 403 915 1685 2498 3545 5597 8804 1273 2066 2961 800 466 1058 1832 2889 4100 6472 1018 1472 2378 3424 900 531 1205 2087 3289 4668 7370 1159 1677 2708 3899

1000 597 1355 2346 3699 5250 8289 1304 1886 3045 4385 1100 665 1509 2612 4119 5845 9228 1451 2099 3390 4882 1200 734 1665 2884 4546 6452 1019 1602 2317 3742 5389 1300 804 1824 3159 4981 7069 1116 1755 2539 4100 5904 1400 875 1986 3438 5421 7693 1215 1910 2763 4462 6425 1500 947 2149 3721 5866 8325 1314 2067 2990 4828 6953 1600 1019 2313 4004 6313 8960 1415 2225 3218 5196 7483 1700 1091 2477 4289 6762 9597 1515 2383 3447 5566middot 8015 1800 1164 2641 4572 7209 1023 1615 2540 3674 5933 8544 1900 1235 2803 4854 7653 1086 1715 2697 3901 6299 9071 2000 1306 2964 5133 8092 1148 1813 2852 4124 6660 9591

Calculating meter capacity To calculate a volume rate for a given velocity multiply the capacity in this table by the desired at the pressure and divide the answer by 100 Example Determine the hourly flow rate al 70 fps for an 8 inch meter operating at 800 psig Volume =7635 MSCFH Velocity 70 Answer = 763570100 = 5344 MSCFH

Pa~e 3

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 20 F and gas composition These values are intended to be a guide In Contact Daniel nee ring for a application

Flow RateS (IASOFH) Based UppJ1 30 mls Schedule 40) kPag 4 6 8 10 12 16 20 24 30 36 1000 967 2201 3811 6007 8527 1346 2117 3062 4945 7121 1500 1422 3234 5600 8827 1253 1978 3111 4500 7267 1046 2000 1885 4289 7428 1171 1662 2624 4127 5969 9639 1388 2500 2359 5367 9294 1465 2079 3283 5164 7469 1206 1737 3000 2843 6468 1120 1765 2506 3956 6223 9000 1453 2093 3500 3337 7592 1315 2072 2941 4644 7304 1056 1706 2457 4000 3841 8739 1513 2385 3386 5346 8408 1216 1964 2828 4500 4356 9910 171S 2705 3840 6062 9535 1379 2227 3207 5000 4881 1111 1923 3031 4303 6793 1068 1546 2495 3593 5500 5417 1232 2134 3364 4774 7538 1186 1715 2769 3987 6000 5962 1 3702 5255 8297 1305 1887 3048 4389 6500 6517 1483 2568 4047 5745 9070 1427 2063 3332 4798 7000 7082 1611 2790 4398 6243 9856 1550 2242 3621 5214 7500 7656 1742 3016 4754 6748 1065 1676 2424 3914 5636 8000 8238 1874 3246 5116 7262 1146 1803 2608 4212 6065 8500 8828 2009 3478 5482 7782 1229 1932 2795 4513 6499 9000 9425 2144 3713 5853 8308 1312 2063 2984 4818 6939 9500 10028 2281 3951 6227 8839 1396 2195 3175 5127 7382

10000 10636 2420 4190 6604 9375 1480 2328 3367 5437 7830

Flow Rates (IANSOND) Based Upon 30 mls (Scnedule 40) PSIG 4 6 8 10 12 16 20 24 30 36 1000 0232 0528 0915 1442 2046 3231 5082 7350 11869 17091 1500 0341 0776 1344 2119 3007 4748 7468 10801 17441 25116 2000 0453 1029 1783 2810 3989 6297 9904 14325 23133 33311 2500 0566 1288 2231 3516 4991 7879 12393 17924 28946 41682 3000 0682 1552 2688 4237 6014 9495 14935 21600 34882 50230 3500 0801 1821 3155 4973 7059 11145 17530 25354 40943 58958 4000 0922 2097 3632 5725 8126 12830 20179 29186 47131 67869 4500 1045 2378 4119 6492 9215 14549 22883 33097 53447 76963 5000 1171 2664 4615 7275 10326 16302 25641 37086 59889 86240 5500 1300 2957 5121 8072 11459 18091 28454 41154 66458 95699 6000 1431 3254 5637 8885 19912 31319 45298 73150 105336 6500 1564 3557 6162 9713 13787 21767 34236 49517 79964 115148 7000 1700 3866 6696 10555 14982 23653 37203 53808 86893 125126 7500 1837 4179 7239 11410 16196 25570 40218 58168 93934 135265 8000 1977 4497 7789 12278 17428 27515 43277 62592 101078 145553 8500 2119 4819 8347 13157 18676 29485 46376 67075 108318 155978 9000 2262 51 8912 14047 19939 31479 71611 115642 166524 9500 2407 5474 9482 14945 21214 33492 52679 76191 123038 177175

10000 2553 5805 10056 15851 22500 35522 55871 80808 130494 187911

Calculating meter capacity To calculate a volume rate for a given velocity the capacity this table by the desired velocity at the operating pressure and divide the answer 100 Determine the hourly flow rate at 30 mps for an 8 inch meter at 4500 Volume 1716 Velocity 10 Answer 17161030 5719 MSCMH

Product Oata Sheet DAN-GFM-DS-21-rev0404 April 2004

The drawings below represent recommended piping lengths for various flow conditioners when installed with the Daniel SeniorSonic flowmeter If shorter lengths are used there may be an increase in flow measurement uncertainty

Piping Recommendation For SeniorSonic With No Flow Conditioner

1~~--------------------200 -----------------------~

Q----I__------shy~

J ~~f --M-I-middotn-im-~-~-p-iP-i-n-g-R-e-c-o-m-m-e-n-a-a-tl-o-n-F-o-r-S-en-I-o-r-S-o-n-ic-W-it-h-D-a-n-ie-l-p-r-O-fi-le-r-o-r-C-p-~-5-0-E~-F--o-w-c-o-n-d-itl-io-n-e-r--

1 00 middot -2 o~o ~1gt

[ _____ ---Al11~ ----- =ul [II I

I 0 0 a It Minimum Piping Recommendation for Bimiddotdirectional SeniorSonic

with Daniel Profiler or CPA 50E Flow Conditioner

~------- 100 ------t ~------- 100 ----~ - 50---shy

3middot 50

-- 50 ---shy

3middot 50

~ -

A WARNING Do not operate this instrument in excess of the specifications listed Failure to heed this warning could result in serious injury andor damage to the equipment

Page 5

---- - --- _ --- ----------------- -------------------------shy

--iI

-------~~--------1

----~----------------I _____________________I

----~------~----__i _____bullmiddot________ ----__i

____________shy____~__i

____________________---i __________________

_________shy__________~~

~ I ~

I

~

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

8

10

12

16

20

24

30

36 r

ANSI Class 300 600--~------------------------i

900__________----__------__------i 1500

-------------------------------~ Flange Raised Face (RF) _________________-_------j

Ring Type Joint (RTJ)___---------__bull-_____Imiddot

Materials Standard ~----~~--~----~--------~~ Stainless Steel

DJplex --~--------------------------~----~ _________________________--____~__

Device Type

Electronics

Transducers

Meter Size (Inches)

Daniel Ultrasonic Model Number Selections ES-21055 RevW

SeniorSonic (4-Path) ---------------1 JuniorSonic (1~Path) ------------1 JuniorSonic (2-Path) ______________

Mark II UL 24VDC 4-20rlA 3NPT

Mark UL 24VDC 1middot5VDC 3NPT ---------------------1 Mark CENaEC 24V DC 4-20mA M20 --------------_--__1

Mark IICB-JELEC24VDC1-SVDCM20

Mark II ClNELEc 24VDC 4-20mA M20 Rerrote

Mark II CENELEC 24VDC 1-5VDCM20 Rerrote

MarkU UL 24VOC4-20mA 3NPT Rerrote_

Mark II U~ 24VDC l-SVPG 3NPT Rerrote

Mark IIIUL 34 NPT

Mark III UL 34NPT Rerrote

TmiddotSlo T-12

4

middot 6

Page 6

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Systems Daniel Measurement and Control is the industry leader in designing constructing and commissioning of complex oil and gas metering systems to exacting standards

This global organization offers decades of petroleum fiscal flow measurement application experience Customers rely confidently on Daniels Systems Group international fabrication facilities customized engineering and its successes in field-testing and support From the simplest single-stream skid to complex on-site installations Daniel Systems delivers both natural gas and liquid petroleum tumkey applications Daniel Systems designs constructs and commissions the metering project blending up-toshythe-minute technology with decades of understanding what customers need and expect

Components of a Daniel Systems installation typically include meters valves provers flow-control instruments instrumentation and read-out equipment and process management components

Computer software and hardware are integrated with the measurement system Standard calculation methods include AGA3 (now API-MPMS-143) ISO 5167 AGA578 AGA9 and the API Manual for Petroleum Measurement Standards

Daniel DMSS-2000 Supervisory Control Systems utilize a sophisticated Graphical User Interface database server and a dedicated PLC for the metering skidMOV interface Redundancy is often used for custody transfer systems andor when system integrity is essential

A dedicated Project Manager and Project Team are assigned to each measurement system project This team is responsible for overall system design and project construction from start to finish A separate internal QAQC group reviews all design detailS inside and outside fabrication assembly and system testing

Whether it is a pipeline offshore production facility or a loading facility for ocean-going tankers the Daniel Systems group is a proven single-source solution for customers throughout the world

Page 7

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Daniel Measurement Services Daniel Measurement Services takes pride in being there after needs arise with the right solution for customers with gas and liquid fiscal flow measurement applications

Around the clock and around the world Daniel Measurement Services has experienced highly qualified people prepared to help customers who need assistance with the following

middot Start-up and commissioning middot Preventive maintenance middot Product repair I upgrades middot Project management and integration middot Meter Tube inspection and recertification middot Remote diagnostics middot Warranty Plus middot Technical training

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880

Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337

Stirling Scotland - UK Middle East amp Africa T +4401786433400 F +44 01786433401

Singapore - Asia Pacific T +65-6777-8211 F +65-6770-8001

USA Toll Free 1-888-FLOW-001 wwwdanielcom

Daniel is a whOlly owned subsidiary of Emerson Electric Co and a division of Emerson Process Management The Daniel logo is a registered trademark of Daniel Industnes tnc The Emerson logo is a trademark and service mark of Emerson Electric Co Brand mark listing are marks of one of the Emerson Process Management family of companies All other marks are property of their respecl ive owners The Daniel UltraSonic Gas Flow Meter including Mark III electronics is covered by US Patents 598330 and 4646 575 and patents pending The contents of this publication are presented for information purposes only and while effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or thel( use or applicability Daniel does not assume responsibility for the selection use or maintenance of any Daniel product Responsibility for proper selection use and maintenance of any Daniel product remains solely wilh the purchaser and end-userAII sales are governed by our terms and conditions which are available upon request We reserve the right to modify or improve the designs or specification of our products at any time without notice

-- -~J ~~--------- EMERSON bull ~ I

copy2004 Daniel Measurement and Control Inc All rights reserved Printed in the USA DAN -GFM-DS-0221-rev0404

reg DAN-3MT-3M-0801 -~I August 2001_-shy

3 SectioQltandProfiler Meter Tubes ~ Pf~6 5 ~~ IrMimiddot~

Instruments You Can Trust Daniel Meter Tubes are more than just fabricated pipe with an orifice fitting They are accurate dependable instruments because of Daniels dedicated approach to quality Extra steps taken during every phase of meter tube design and production separate Daniel Meter Tubes from all the rest

The Daniel 3 section meter tube is available with any style Senior or Junior orifice fitting Simplex plate holder or orifice flanges The assembly contains an inlet spool of the minimum length prescribed by the 143 standard The second section begins with a concentric flange mounted tube bund=1 leetln9 the 2000 API 143 requirements and a W thick spacer plate to ease tube removal for inspection The 04~r end of section 2 conshytains the orifice flange or fitting The third or downstream section follows and contains 2 branchOonnections and is extra long to allow for the addition of extra branch conshynections in the field If desired The standard meter tube has flanged outer ends Other end connections are avaUable on request

Inspectionffesting= Daniel maintains rigid inspection procedures during manufacturing of meter tubes Micrometer and internal surface roughness readings are recorded and supplied with each meter tUbe Customer or third party inspectors are welcome to verify these readings Radiography of welds is another service that is available

Fabrication Fabrication of your instrument Includes attaching the orifice fitting to the meter tube to make an integral primary measuring element For welding operashytions Daniel uses automatic welding machines and rotatshying positioners Highly skilled code qualified welders are employed to tum out highest quality on each job Special internal jigs and fixtures are used to insure smooth Inlet and outlet surfaces without steps or offsets All welds receive expert grinding by experienced craftsshy

men X

cl

-

gt shy

~

-

J ~

Features bull Dowel pin alignment close tolerance maleffemale

flange or knock out dowel pins insure that the bores of sections two and three are matched without offsets

One 1h and one 0 branch connection on the downstream for thermowell or other uses standard

Beveled flanged or reduced ends as well as any available weld fitting can be furnished on the ends of the tubes

Hydrostatically tested after manufacture

Each orifice fitting is tested for tap hole and orifice plate seal integrity after the meter tube has been pressure tested

Material Selection Daniel uses special cold drawn seamless tubing or honed pipe in the fabrication of meter tubes The strict reqUirements for intemal roundshyness and surface finish preclude the use of standard commercial pipe in most cases Daniel maintains a large inventory of this special pipe to rapidly complete your order

LT

EMERSON~ ltocess Management

~~------------------------------------------------------------~------------------------------

Raised Face Weld neck

NA

3M-30RW

3M-60RW High Pressure

3M-90RW 3M-150RW 3M-250RW

DAN-3MT-3M-0801 August 2001

3 Section Meter Tube Catalog Numbers 2-12 with Senior Fitting 10 amp 12 with Junior Fittina

~

Pressure Rating

150

Flange by Weld

(Flangnek)

3M-011

Flange by Flange

(Flanged)

3M-101

Weld by Weld

(Weldnek)

NA

Flange by Weld

(Flangnek)

3M-021

Flange by Flange

(Flanged)

3M-201

Weld by Weld

(Weldnek)

NA

300 3M-013 3M-103 NA 3M-023 3M-203 NA

600 3M-015 3M-105 3M-185 3M-025 3M-205 3M-285

H~h Pressure 3 Section Meter Tubes 900 3M-016 3M-106 3M-186 3M-026 3M-206 3M-286

1500 3M-017 3M-107 3M-187 3M-027 3M-207 3M-287

2500 3M-018 3M-108 3M-188 3M-028 3M-208 3M-288

2middot8 with Simplex 2middot12 with Orifice Flanges Flange byPressure

WeldRating Weld by Weld (Flangnek) (Weldnek)

150 3M-071 NA 3M-073300 NA

600 3M-075 3M-705 High Pressure

3M-7063M-076900 3M-7071500 3M-077 3M-7083M-0782500 -

Two Section Meter Tubes When Usmg Weldnek Flttmgs

Senior and Simplex fittings are also available in 10000 psi rating in some sizes All units are also available with Ring Type Joint (RTJ) flanges on request Sizes larger than 12 available on request

PackingShipping Daniel bolts together all meter A SPECIAL NOTE The use of factory original Daniel tubes when size permits before shipment This saves parts will assure your Senior Junior and Simplex Orifice the user time and field labor costs Fittings are protectshy fittings will stay within original specifications and operate ed by heavy lumber and the tube flanges by special-cut properly protectors

PaintingCoating The Daniel standard paint is a basic enamel type Special coatings such as multi-coat

offshore systems are available on request

3~Section Meter Tube with Tube Bundle

~-----~ U ----~---------~=~~middotmiddotmiddotmiddot~middot t)middotmiddot-middot ~- - -0bull )00)00 1

I~IC--middotmiddotmiddot-middot -----shyshy-bullmiddotV ------- ~

~ - ~-

~

ii~pound bullbullbull ~

Standard lenAths Size un Upstream 0 Downstream V (vane location)

3 7-5 4-0 130 4 9~~9 4-0 130

6 14-8 5-0 t30

102410 60middot middot 130 1~ +1 2tYS Tq 130 JiIf

Note Straightening vanes are not available in 2line size (See Dald Profller DAN-1852middot 2M)

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Daniel meter tubes can be supshyplied in many combinations and configurations Any of the orifice fittings plate holders or orifice flanges can be included in a meter tube Each 3 section standard meter tube is equipped with a flange mounted tube bundle straightener In accordance with April 2000 API 143 and a 1h thick spacer to facilitate tube removal for inspection Downstreams are longer than minimum required to allow for field Installation of additional branch connections If required

To specify a 3 section meter tube use the designation 3M followed by the type orifice holding deVice Ex 4 600 3 section meter tube with flanged ends using a Senior fitting flangneck style is specified as 4-3M-015 The same unit with a weldneck style Simplex is specified as 4middot3M-705 When ordering specify pipe schedule and end configuration Larger size and custom meter tube designs are available on request

The Daniel Profilertrade three section meter tube is availshy lows and contains 2 branch connections Other or addi able with any style Senior or Junior orifice fitting Simplex tiona I connections can be supplied in this section on plate holder or orifice flanges The assembly contains an request These meter tubes are for use in any piping conshyinlet spool of tile minimum length determined during testshy figuration with beta ratios to 67 Downstream sections ing to the API 143 standard The flange union between are extra long to allow for the addition of extra branch the first and second sections contains the ProfilerN and connections in the field if desired The standard meter a Y2 thick spacer plate to facilitate tube removal for tube has beveled outer ends Flanges or other end conshyinspection The outer end of section 2 contains the orishy nections are available on request fice flange or fitting The third or downstream section fol

Meter Tubes Catalog Numbers - 2 WI emor In9 bull Wit un or Itt ng2 1 th S Fitt 10 amp 12 h J i F i

Pressure Rating

Flange by Weld

(F1angnek)

Flange by Flange

(Flanged)

Weld by Weld

(Weldnek)

Flange by Weld

(Flangnek)

Flange by Flange

(Flanged)

Weld by Weld

(WeJdnek) 150 M011 M-101 NA M-021 M-201 NA 300 M-Q13 M-103 NA M023 M-203

NA 600 M-015 M-105 M-t85 M-025 M-205 M-285

2middot8 with Simplex 2middot12 with Orifice Flanges

Pressure Rating

Flange by Weld

weld by Weld

(Weldnek)CFlananekl 150 M-071 NA 300 M-073 NJA 6QfJ M-()75 M-705

Raised Face Weld Neck

NA - -

lM-30RW M-60RW

Two Section Meter Tube When USing Weldnek Fittings

Consult Factory for High Pressure Applications

PROFILERTM Flow Conditioning Plate

The Profiler has been tested and Shown to be in full compliance with the requirementS of API 143 April 2000 The Profiler both removes swirl

the tube bundle Available In flange mounted model only Also available In RTJ style on request

and creates a fully developed flow profile at the orifice Use of this unit allows shortened upstream straight pipe lengths of 17 diameters Beta ratio limit is 67 as with

-~---

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 9: Medidor de Flujo

Product Data Sheet DAN-GFM-DS -21-rev0404 ( )

April2004 SeniorSonic with Mark TM Electronics

- SeniorSonic The Daniel SeniorSonic Gas Flow Meter with Mark IWM Electronics saves you time and money Lost and unaccounted for gas is reduced by exceptional low and high flow accuracy and linearity throughout the calibrated flow range Time is saved by a best-in-class audit trail Mark III Electronics can pinpoint alarms events and configuration changes in a matter of seconds Best of all operating the Daniel SeniorSonic gas flow meter is easy with the Windowsreg based Daniel Customer User Interface (CUI) software

Features middot Excellent long-term performance

Velocity Range Most sizes are rated to performa at 100 fps middot Full electronic audit trail (exceeds API 211) Over-range of up to 125 fps and in some cases beyond 125 middot Exceptional low and high flow performance

middot Bi-directional multi-point calibration coefficients fps in emergencymiddot situations and without transducer failure

middot Rangeability exceeds 50 1 with calibration Availability is limited by line size and ANSI rating Visit middot ANSI 30060090015002500 versions wwwdanielcomseniorsonic for additional information middot Extractable transducers (For all sizes) middot Minimum upstream piping requirements Meter specifications

Gas temperature -4 to +212deg F (-20 to +100deg C) Easy to learn and use CUI software features Operating pressure range 150 - 3750 psig middot Comprehensive monitor screen (1030 - 25855 kPa) Consult factory for lower and middot Field start-up wizard higher pressure applications middot Calibration wizards (analog and frequency) Flanges RF for 3001500 RTJ for 6002500 middot Flow calibration configuration wizard middot Audit 1 alarm 1history retrieval Power DC version - 1224 (11-36) VDC 6 watts maximum middot Digital waveform viewing middot Maintenance log summary in ExcelI Environmental middot Built-in AGA 10 SOS calculator Operating temperature -40 to +149deg F (-40 to +65deg C) middot Automatic file naming Operating relative humidity up to 95 non-condensing middot Trending of maintenance logs Storage temperature -40 to +185 0 F (-40 to +85 0 C) middot Configuration comparison with exception summary middot Remote dial-up support and Ethernet support Typical Applications middot Unlimited meter directory support middot Custody transfer

middot Power plants Specifications middot Large industrial users

Electronic unit middot City gates Communication protocol Modbus RTUASCII amp TCPIIP middot Production Two serial RS-232485 ports and Ethernet middot Underground storage sites Communication speed Up to 115 KBPS middot Offshore Frequency outputs Four Frequency range 0-10005000 Hz Safety classifications Digital output Selectable (up to four for data valid or flow UL listed for use in Class I Division 1 Group D hazardous

direction) locations in both the US and Canada (UL E152246) Calculation update time Configurable for 14 and 1 second CE marked to ATEX directive (949EC ) (pending)

Certified to Eex d ia liB T4 to standards EN 50014 EN 50018 Accuracy and EN 50020 (pending) Flow calibrated accuracy plusmn 01 (Relative to lab) Absolute accuracy Including lab uncertainty about 03 Repeatability plusmn 02 of reading for Ot to Omax

-- - tI II~ EMERSON ~-----

wwwdanielcom

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Recommended Ma~jum Flow Velocity Meter Size J Meter Size Metric Max Inches Max ftI~ m tris

4 100 100 30 6 100 150 30 8 100 200 30

10 80 250 24 12 80 300 24 16 85 400 26 20 85 500 26 24 85 600 26 30 70 750 21 36 70 900 21

Dimensions These measurements are meant only as an aid in the design of metering systems Consult Daniel engineering drawings prior to construction

Typical 600 ANSI Meter with 45 Degree-Angled Transducers Overall End- Flange Approximate Overall End- Flange Approximate

Meter Size To-End Diameter Weight To-End Diameter Weight (Inches) (Inches) (Inches) (Pounds) (Millimeters) (Millimeters) (Kilograms)

4 2900 1075 370 737 273 168 6 2950 1400 460 749 356 209

8 3150 1650 650 800 419 295 10 3400 2000 885 864 508 402 12 3544 2200 1075 900 559 489 16 4400 2700 1955 1118 686 889 18 4531 2925 2800 11sect1 743 1273 20 5062 3200 30Z5 12amp6 84~ 1398

0 4 5862 3700 404~ 1489 940 1839 30 6700 4450 4925 1702 1130 2239 36 7350 5175 6425 1867 1314 2920

()l p l ( C flO

bull I iY0

e

Page 2

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 60 F and gas composition These values are intended to be a guide in Contact Daniel engineering for a specific application

_ Flow Rates (JIISCFHl Basea Upon 100 ftls PSIG 4 6 8 10 12 16 20 24 30 36 100 247 561 971 1532 2174 3432 5398 7807 12607 18154 200 468 1065 1845 2908 4127 6515 10248 14822 23935 34467 300 696 1584 2743 4325 6137 9690 15240 22043 35596 51258 400 931 2118 3668 5782 8206 12955 20377 29472 47593 68534 500 2667 4619 7282 10334 16315 25661 37114 59934 86305 600 1421 3232 5597 8823 12522 19770 31095 44973 72626 104582 700 1676 3813 6602 10409 14772 23322 36682 53055 85677 123374 800 1938 4409 7635 12036 17082 26968 42417 61349 99070 142661 900 2207 5021 8694 13706 19452 30710 48302 69861 112816 162455 1000 2482 5646 9777 15414 21875 34536 54320 78565 126872 182696 1100 2763 6286 10885 17161 24355 38451 60478 87471 141254 203405 1200 3050 6939 12015 18943 26883 42443 66756 96551 155917 224521 1300 3341 7602 13164 20753 29453 46500 73137 105781 170822 245983 1400 3637 8274 14327 22587 32055 50608 79599 115127 185915 267718 1500 3935 8953 15504 24442 34688 54765 86137 124583 201184 289706 1600 4235 9635 16685 26305 37331 58938 92700 134076 216515 311781 1700 4536 10321 17871 28175 39986 63128 99291 143608 231908 333948 1800 4836 11002 19052 30036 42627 67298 105850 153094 247227 356006 1900 5134 11681 20226 31888 45255 71448 112376 162534 262471 377958 2000 5429 12350 21386 33716 47849 75543 118818 171851 277516 399623

Flow Rates (MIfIISCFfJ) Based Upon 100 ffls PSIG 4 6 8 10 12 16 20 24 30 36 100 59 135 233 368 522 824 1295 1874 3026 4357 200 113 256 443 698 990 1564 2459 3557 5744 8272 300 168 380 658 1038 1473 2326 3658 5290 8543 1230 400 224 508 880 1388 1969 3109 4890 7073 1142 1645 600 282 640 110~ 1748 2480 3916 6159 8907 1438 2071 600 342 776 1343 2118 3005 4745 7463 1079 1743 2510 700 403 915 1685 2498 3545 5597 8804 1273 2066 2961 800 466 1058 1832 2889 4100 6472 1018 1472 2378 3424 900 531 1205 2087 3289 4668 7370 1159 1677 2708 3899

1000 597 1355 2346 3699 5250 8289 1304 1886 3045 4385 1100 665 1509 2612 4119 5845 9228 1451 2099 3390 4882 1200 734 1665 2884 4546 6452 1019 1602 2317 3742 5389 1300 804 1824 3159 4981 7069 1116 1755 2539 4100 5904 1400 875 1986 3438 5421 7693 1215 1910 2763 4462 6425 1500 947 2149 3721 5866 8325 1314 2067 2990 4828 6953 1600 1019 2313 4004 6313 8960 1415 2225 3218 5196 7483 1700 1091 2477 4289 6762 9597 1515 2383 3447 5566middot 8015 1800 1164 2641 4572 7209 1023 1615 2540 3674 5933 8544 1900 1235 2803 4854 7653 1086 1715 2697 3901 6299 9071 2000 1306 2964 5133 8092 1148 1813 2852 4124 6660 9591

Calculating meter capacity To calculate a volume rate for a given velocity multiply the capacity in this table by the desired at the pressure and divide the answer by 100 Example Determine the hourly flow rate al 70 fps for an 8 inch meter operating at 800 psig Volume =7635 MSCFH Velocity 70 Answer = 763570100 = 5344 MSCFH

Pa~e 3

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 20 F and gas composition These values are intended to be a guide In Contact Daniel nee ring for a application

Flow RateS (IASOFH) Based UppJ1 30 mls Schedule 40) kPag 4 6 8 10 12 16 20 24 30 36 1000 967 2201 3811 6007 8527 1346 2117 3062 4945 7121 1500 1422 3234 5600 8827 1253 1978 3111 4500 7267 1046 2000 1885 4289 7428 1171 1662 2624 4127 5969 9639 1388 2500 2359 5367 9294 1465 2079 3283 5164 7469 1206 1737 3000 2843 6468 1120 1765 2506 3956 6223 9000 1453 2093 3500 3337 7592 1315 2072 2941 4644 7304 1056 1706 2457 4000 3841 8739 1513 2385 3386 5346 8408 1216 1964 2828 4500 4356 9910 171S 2705 3840 6062 9535 1379 2227 3207 5000 4881 1111 1923 3031 4303 6793 1068 1546 2495 3593 5500 5417 1232 2134 3364 4774 7538 1186 1715 2769 3987 6000 5962 1 3702 5255 8297 1305 1887 3048 4389 6500 6517 1483 2568 4047 5745 9070 1427 2063 3332 4798 7000 7082 1611 2790 4398 6243 9856 1550 2242 3621 5214 7500 7656 1742 3016 4754 6748 1065 1676 2424 3914 5636 8000 8238 1874 3246 5116 7262 1146 1803 2608 4212 6065 8500 8828 2009 3478 5482 7782 1229 1932 2795 4513 6499 9000 9425 2144 3713 5853 8308 1312 2063 2984 4818 6939 9500 10028 2281 3951 6227 8839 1396 2195 3175 5127 7382

10000 10636 2420 4190 6604 9375 1480 2328 3367 5437 7830

Flow Rates (IANSOND) Based Upon 30 mls (Scnedule 40) PSIG 4 6 8 10 12 16 20 24 30 36 1000 0232 0528 0915 1442 2046 3231 5082 7350 11869 17091 1500 0341 0776 1344 2119 3007 4748 7468 10801 17441 25116 2000 0453 1029 1783 2810 3989 6297 9904 14325 23133 33311 2500 0566 1288 2231 3516 4991 7879 12393 17924 28946 41682 3000 0682 1552 2688 4237 6014 9495 14935 21600 34882 50230 3500 0801 1821 3155 4973 7059 11145 17530 25354 40943 58958 4000 0922 2097 3632 5725 8126 12830 20179 29186 47131 67869 4500 1045 2378 4119 6492 9215 14549 22883 33097 53447 76963 5000 1171 2664 4615 7275 10326 16302 25641 37086 59889 86240 5500 1300 2957 5121 8072 11459 18091 28454 41154 66458 95699 6000 1431 3254 5637 8885 19912 31319 45298 73150 105336 6500 1564 3557 6162 9713 13787 21767 34236 49517 79964 115148 7000 1700 3866 6696 10555 14982 23653 37203 53808 86893 125126 7500 1837 4179 7239 11410 16196 25570 40218 58168 93934 135265 8000 1977 4497 7789 12278 17428 27515 43277 62592 101078 145553 8500 2119 4819 8347 13157 18676 29485 46376 67075 108318 155978 9000 2262 51 8912 14047 19939 31479 71611 115642 166524 9500 2407 5474 9482 14945 21214 33492 52679 76191 123038 177175

10000 2553 5805 10056 15851 22500 35522 55871 80808 130494 187911

Calculating meter capacity To calculate a volume rate for a given velocity the capacity this table by the desired velocity at the operating pressure and divide the answer 100 Determine the hourly flow rate at 30 mps for an 8 inch meter at 4500 Volume 1716 Velocity 10 Answer 17161030 5719 MSCMH

Product Oata Sheet DAN-GFM-DS-21-rev0404 April 2004

The drawings below represent recommended piping lengths for various flow conditioners when installed with the Daniel SeniorSonic flowmeter If shorter lengths are used there may be an increase in flow measurement uncertainty

Piping Recommendation For SeniorSonic With No Flow Conditioner

1~~--------------------200 -----------------------~

Q----I__------shy~

J ~~f --M-I-middotn-im-~-~-p-iP-i-n-g-R-e-c-o-m-m-e-n-a-a-tl-o-n-F-o-r-S-en-I-o-r-S-o-n-ic-W-it-h-D-a-n-ie-l-p-r-O-fi-le-r-o-r-C-p-~-5-0-E~-F--o-w-c-o-n-d-itl-io-n-e-r--

1 00 middot -2 o~o ~1gt

[ _____ ---Al11~ ----- =ul [II I

I 0 0 a It Minimum Piping Recommendation for Bimiddotdirectional SeniorSonic

with Daniel Profiler or CPA 50E Flow Conditioner

~------- 100 ------t ~------- 100 ----~ - 50---shy

3middot 50

-- 50 ---shy

3middot 50

~ -

A WARNING Do not operate this instrument in excess of the specifications listed Failure to heed this warning could result in serious injury andor damage to the equipment

Page 5

---- - --- _ --- ----------------- -------------------------shy

--iI

-------~~--------1

----~----------------I _____________________I

----~------~----__i _____bullmiddot________ ----__i

____________shy____~__i

____________________---i __________________

_________shy__________~~

~ I ~

I

~

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

8

10

12

16

20

24

30

36 r

ANSI Class 300 600--~------------------------i

900__________----__------__------i 1500

-------------------------------~ Flange Raised Face (RF) _________________-_------j

Ring Type Joint (RTJ)___---------__bull-_____Imiddot

Materials Standard ~----~~--~----~--------~~ Stainless Steel

DJplex --~--------------------------~----~ _________________________--____~__

Device Type

Electronics

Transducers

Meter Size (Inches)

Daniel Ultrasonic Model Number Selections ES-21055 RevW

SeniorSonic (4-Path) ---------------1 JuniorSonic (1~Path) ------------1 JuniorSonic (2-Path) ______________

Mark II UL 24VDC 4-20rlA 3NPT

Mark UL 24VDC 1middot5VDC 3NPT ---------------------1 Mark CENaEC 24V DC 4-20mA M20 --------------_--__1

Mark IICB-JELEC24VDC1-SVDCM20

Mark II ClNELEc 24VDC 4-20mA M20 Rerrote

Mark II CENELEC 24VDC 1-5VDCM20 Rerrote

MarkU UL 24VOC4-20mA 3NPT Rerrote_

Mark II U~ 24VDC l-SVPG 3NPT Rerrote

Mark IIIUL 34 NPT

Mark III UL 34NPT Rerrote

TmiddotSlo T-12

4

middot 6

Page 6

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Systems Daniel Measurement and Control is the industry leader in designing constructing and commissioning of complex oil and gas metering systems to exacting standards

This global organization offers decades of petroleum fiscal flow measurement application experience Customers rely confidently on Daniels Systems Group international fabrication facilities customized engineering and its successes in field-testing and support From the simplest single-stream skid to complex on-site installations Daniel Systems delivers both natural gas and liquid petroleum tumkey applications Daniel Systems designs constructs and commissions the metering project blending up-toshythe-minute technology with decades of understanding what customers need and expect

Components of a Daniel Systems installation typically include meters valves provers flow-control instruments instrumentation and read-out equipment and process management components

Computer software and hardware are integrated with the measurement system Standard calculation methods include AGA3 (now API-MPMS-143) ISO 5167 AGA578 AGA9 and the API Manual for Petroleum Measurement Standards

Daniel DMSS-2000 Supervisory Control Systems utilize a sophisticated Graphical User Interface database server and a dedicated PLC for the metering skidMOV interface Redundancy is often used for custody transfer systems andor when system integrity is essential

A dedicated Project Manager and Project Team are assigned to each measurement system project This team is responsible for overall system design and project construction from start to finish A separate internal QAQC group reviews all design detailS inside and outside fabrication assembly and system testing

Whether it is a pipeline offshore production facility or a loading facility for ocean-going tankers the Daniel Systems group is a proven single-source solution for customers throughout the world

Page 7

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Daniel Measurement Services Daniel Measurement Services takes pride in being there after needs arise with the right solution for customers with gas and liquid fiscal flow measurement applications

Around the clock and around the world Daniel Measurement Services has experienced highly qualified people prepared to help customers who need assistance with the following

middot Start-up and commissioning middot Preventive maintenance middot Product repair I upgrades middot Project management and integration middot Meter Tube inspection and recertification middot Remote diagnostics middot Warranty Plus middot Technical training

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880

Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337

Stirling Scotland - UK Middle East amp Africa T +4401786433400 F +44 01786433401

Singapore - Asia Pacific T +65-6777-8211 F +65-6770-8001

USA Toll Free 1-888-FLOW-001 wwwdanielcom

Daniel is a whOlly owned subsidiary of Emerson Electric Co and a division of Emerson Process Management The Daniel logo is a registered trademark of Daniel Industnes tnc The Emerson logo is a trademark and service mark of Emerson Electric Co Brand mark listing are marks of one of the Emerson Process Management family of companies All other marks are property of their respecl ive owners The Daniel UltraSonic Gas Flow Meter including Mark III electronics is covered by US Patents 598330 and 4646 575 and patents pending The contents of this publication are presented for information purposes only and while effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or thel( use or applicability Daniel does not assume responsibility for the selection use or maintenance of any Daniel product Responsibility for proper selection use and maintenance of any Daniel product remains solely wilh the purchaser and end-userAII sales are governed by our terms and conditions which are available upon request We reserve the right to modify or improve the designs or specification of our products at any time without notice

-- -~J ~~--------- EMERSON bull ~ I

copy2004 Daniel Measurement and Control Inc All rights reserved Printed in the USA DAN -GFM-DS-0221-rev0404

reg DAN-3MT-3M-0801 -~I August 2001_-shy

3 SectioQltandProfiler Meter Tubes ~ Pf~6 5 ~~ IrMimiddot~

Instruments You Can Trust Daniel Meter Tubes are more than just fabricated pipe with an orifice fitting They are accurate dependable instruments because of Daniels dedicated approach to quality Extra steps taken during every phase of meter tube design and production separate Daniel Meter Tubes from all the rest

The Daniel 3 section meter tube is available with any style Senior or Junior orifice fitting Simplex plate holder or orifice flanges The assembly contains an inlet spool of the minimum length prescribed by the 143 standard The second section begins with a concentric flange mounted tube bund=1 leetln9 the 2000 API 143 requirements and a W thick spacer plate to ease tube removal for inspection The 04~r end of section 2 conshytains the orifice flange or fitting The third or downstream section follows and contains 2 branchOonnections and is extra long to allow for the addition of extra branch conshynections in the field If desired The standard meter tube has flanged outer ends Other end connections are avaUable on request

Inspectionffesting= Daniel maintains rigid inspection procedures during manufacturing of meter tubes Micrometer and internal surface roughness readings are recorded and supplied with each meter tUbe Customer or third party inspectors are welcome to verify these readings Radiography of welds is another service that is available

Fabrication Fabrication of your instrument Includes attaching the orifice fitting to the meter tube to make an integral primary measuring element For welding operashytions Daniel uses automatic welding machines and rotatshying positioners Highly skilled code qualified welders are employed to tum out highest quality on each job Special internal jigs and fixtures are used to insure smooth Inlet and outlet surfaces without steps or offsets All welds receive expert grinding by experienced craftsshy

men X

cl

-

gt shy

~

-

J ~

Features bull Dowel pin alignment close tolerance maleffemale

flange or knock out dowel pins insure that the bores of sections two and three are matched without offsets

One 1h and one 0 branch connection on the downstream for thermowell or other uses standard

Beveled flanged or reduced ends as well as any available weld fitting can be furnished on the ends of the tubes

Hydrostatically tested after manufacture

Each orifice fitting is tested for tap hole and orifice plate seal integrity after the meter tube has been pressure tested

Material Selection Daniel uses special cold drawn seamless tubing or honed pipe in the fabrication of meter tubes The strict reqUirements for intemal roundshyness and surface finish preclude the use of standard commercial pipe in most cases Daniel maintains a large inventory of this special pipe to rapidly complete your order

LT

EMERSON~ ltocess Management

~~------------------------------------------------------------~------------------------------

Raised Face Weld neck

NA

3M-30RW

3M-60RW High Pressure

3M-90RW 3M-150RW 3M-250RW

DAN-3MT-3M-0801 August 2001

3 Section Meter Tube Catalog Numbers 2-12 with Senior Fitting 10 amp 12 with Junior Fittina

~

Pressure Rating

150

Flange by Weld

(Flangnek)

3M-011

Flange by Flange

(Flanged)

3M-101

Weld by Weld

(Weldnek)

NA

Flange by Weld

(Flangnek)

3M-021

Flange by Flange

(Flanged)

3M-201

Weld by Weld

(Weldnek)

NA

300 3M-013 3M-103 NA 3M-023 3M-203 NA

600 3M-015 3M-105 3M-185 3M-025 3M-205 3M-285

H~h Pressure 3 Section Meter Tubes 900 3M-016 3M-106 3M-186 3M-026 3M-206 3M-286

1500 3M-017 3M-107 3M-187 3M-027 3M-207 3M-287

2500 3M-018 3M-108 3M-188 3M-028 3M-208 3M-288

2middot8 with Simplex 2middot12 with Orifice Flanges Flange byPressure

WeldRating Weld by Weld (Flangnek) (Weldnek)

150 3M-071 NA 3M-073300 NA

600 3M-075 3M-705 High Pressure

3M-7063M-076900 3M-7071500 3M-077 3M-7083M-0782500 -

Two Section Meter Tubes When Usmg Weldnek Flttmgs

Senior and Simplex fittings are also available in 10000 psi rating in some sizes All units are also available with Ring Type Joint (RTJ) flanges on request Sizes larger than 12 available on request

PackingShipping Daniel bolts together all meter A SPECIAL NOTE The use of factory original Daniel tubes when size permits before shipment This saves parts will assure your Senior Junior and Simplex Orifice the user time and field labor costs Fittings are protectshy fittings will stay within original specifications and operate ed by heavy lumber and the tube flanges by special-cut properly protectors

PaintingCoating The Daniel standard paint is a basic enamel type Special coatings such as multi-coat

offshore systems are available on request

3~Section Meter Tube with Tube Bundle

~-----~ U ----~---------~=~~middotmiddotmiddotmiddot~middot t)middotmiddot-middot ~- - -0bull )00)00 1

I~IC--middotmiddotmiddot-middot -----shyshy-bullmiddotV ------- ~

~ - ~-

~

ii~pound bullbullbull ~

Standard lenAths Size un Upstream 0 Downstream V (vane location)

3 7-5 4-0 130 4 9~~9 4-0 130

6 14-8 5-0 t30

102410 60middot middot 130 1~ +1 2tYS Tq 130 JiIf

Note Straightening vanes are not available in 2line size (See Dald Profller DAN-1852middot 2M)

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Daniel meter tubes can be supshyplied in many combinations and configurations Any of the orifice fittings plate holders or orifice flanges can be included in a meter tube Each 3 section standard meter tube is equipped with a flange mounted tube bundle straightener In accordance with April 2000 API 143 and a 1h thick spacer to facilitate tube removal for inspection Downstreams are longer than minimum required to allow for field Installation of additional branch connections If required

To specify a 3 section meter tube use the designation 3M followed by the type orifice holding deVice Ex 4 600 3 section meter tube with flanged ends using a Senior fitting flangneck style is specified as 4-3M-015 The same unit with a weldneck style Simplex is specified as 4middot3M-705 When ordering specify pipe schedule and end configuration Larger size and custom meter tube designs are available on request

The Daniel Profilertrade three section meter tube is availshy lows and contains 2 branch connections Other or addi able with any style Senior or Junior orifice fitting Simplex tiona I connections can be supplied in this section on plate holder or orifice flanges The assembly contains an request These meter tubes are for use in any piping conshyinlet spool of tile minimum length determined during testshy figuration with beta ratios to 67 Downstream sections ing to the API 143 standard The flange union between are extra long to allow for the addition of extra branch the first and second sections contains the ProfilerN and connections in the field if desired The standard meter a Y2 thick spacer plate to facilitate tube removal for tube has beveled outer ends Flanges or other end conshyinspection The outer end of section 2 contains the orishy nections are available on request fice flange or fitting The third or downstream section fol

Meter Tubes Catalog Numbers - 2 WI emor In9 bull Wit un or Itt ng2 1 th S Fitt 10 amp 12 h J i F i

Pressure Rating

Flange by Weld

(F1angnek)

Flange by Flange

(Flanged)

Weld by Weld

(Weldnek)

Flange by Weld

(Flangnek)

Flange by Flange

(Flanged)

Weld by Weld

(WeJdnek) 150 M011 M-101 NA M-021 M-201 NA 300 M-Q13 M-103 NA M023 M-203

NA 600 M-015 M-105 M-t85 M-025 M-205 M-285

2middot8 with Simplex 2middot12 with Orifice Flanges

Pressure Rating

Flange by Weld

weld by Weld

(Weldnek)CFlananekl 150 M-071 NA 300 M-073 NJA 6QfJ M-()75 M-705

Raised Face Weld Neck

NA - -

lM-30RW M-60RW

Two Section Meter Tube When USing Weldnek Fittings

Consult Factory for High Pressure Applications

PROFILERTM Flow Conditioning Plate

The Profiler has been tested and Shown to be in full compliance with the requirementS of API 143 April 2000 The Profiler both removes swirl

the tube bundle Available In flange mounted model only Also available In RTJ style on request

and creates a fully developed flow profile at the orifice Use of this unit allows shortened upstream straight pipe lengths of 17 diameters Beta ratio limit is 67 as with

-~---

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 10: Medidor de Flujo

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Recommended Ma~jum Flow Velocity Meter Size J Meter Size Metric Max Inches Max ftI~ m tris

4 100 100 30 6 100 150 30 8 100 200 30

10 80 250 24 12 80 300 24 16 85 400 26 20 85 500 26 24 85 600 26 30 70 750 21 36 70 900 21

Dimensions These measurements are meant only as an aid in the design of metering systems Consult Daniel engineering drawings prior to construction

Typical 600 ANSI Meter with 45 Degree-Angled Transducers Overall End- Flange Approximate Overall End- Flange Approximate

Meter Size To-End Diameter Weight To-End Diameter Weight (Inches) (Inches) (Inches) (Pounds) (Millimeters) (Millimeters) (Kilograms)

4 2900 1075 370 737 273 168 6 2950 1400 460 749 356 209

8 3150 1650 650 800 419 295 10 3400 2000 885 864 508 402 12 3544 2200 1075 900 559 489 16 4400 2700 1955 1118 686 889 18 4531 2925 2800 11sect1 743 1273 20 5062 3200 30Z5 12amp6 84~ 1398

0 4 5862 3700 404~ 1489 940 1839 30 6700 4450 4925 1702 1130 2239 36 7350 5175 6425 1867 1314 2920

()l p l ( C flO

bull I iY0

e

Page 2

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 60 F and gas composition These values are intended to be a guide in Contact Daniel engineering for a specific application

_ Flow Rates (JIISCFHl Basea Upon 100 ftls PSIG 4 6 8 10 12 16 20 24 30 36 100 247 561 971 1532 2174 3432 5398 7807 12607 18154 200 468 1065 1845 2908 4127 6515 10248 14822 23935 34467 300 696 1584 2743 4325 6137 9690 15240 22043 35596 51258 400 931 2118 3668 5782 8206 12955 20377 29472 47593 68534 500 2667 4619 7282 10334 16315 25661 37114 59934 86305 600 1421 3232 5597 8823 12522 19770 31095 44973 72626 104582 700 1676 3813 6602 10409 14772 23322 36682 53055 85677 123374 800 1938 4409 7635 12036 17082 26968 42417 61349 99070 142661 900 2207 5021 8694 13706 19452 30710 48302 69861 112816 162455 1000 2482 5646 9777 15414 21875 34536 54320 78565 126872 182696 1100 2763 6286 10885 17161 24355 38451 60478 87471 141254 203405 1200 3050 6939 12015 18943 26883 42443 66756 96551 155917 224521 1300 3341 7602 13164 20753 29453 46500 73137 105781 170822 245983 1400 3637 8274 14327 22587 32055 50608 79599 115127 185915 267718 1500 3935 8953 15504 24442 34688 54765 86137 124583 201184 289706 1600 4235 9635 16685 26305 37331 58938 92700 134076 216515 311781 1700 4536 10321 17871 28175 39986 63128 99291 143608 231908 333948 1800 4836 11002 19052 30036 42627 67298 105850 153094 247227 356006 1900 5134 11681 20226 31888 45255 71448 112376 162534 262471 377958 2000 5429 12350 21386 33716 47849 75543 118818 171851 277516 399623

Flow Rates (MIfIISCFfJ) Based Upon 100 ffls PSIG 4 6 8 10 12 16 20 24 30 36 100 59 135 233 368 522 824 1295 1874 3026 4357 200 113 256 443 698 990 1564 2459 3557 5744 8272 300 168 380 658 1038 1473 2326 3658 5290 8543 1230 400 224 508 880 1388 1969 3109 4890 7073 1142 1645 600 282 640 110~ 1748 2480 3916 6159 8907 1438 2071 600 342 776 1343 2118 3005 4745 7463 1079 1743 2510 700 403 915 1685 2498 3545 5597 8804 1273 2066 2961 800 466 1058 1832 2889 4100 6472 1018 1472 2378 3424 900 531 1205 2087 3289 4668 7370 1159 1677 2708 3899

1000 597 1355 2346 3699 5250 8289 1304 1886 3045 4385 1100 665 1509 2612 4119 5845 9228 1451 2099 3390 4882 1200 734 1665 2884 4546 6452 1019 1602 2317 3742 5389 1300 804 1824 3159 4981 7069 1116 1755 2539 4100 5904 1400 875 1986 3438 5421 7693 1215 1910 2763 4462 6425 1500 947 2149 3721 5866 8325 1314 2067 2990 4828 6953 1600 1019 2313 4004 6313 8960 1415 2225 3218 5196 7483 1700 1091 2477 4289 6762 9597 1515 2383 3447 5566middot 8015 1800 1164 2641 4572 7209 1023 1615 2540 3674 5933 8544 1900 1235 2803 4854 7653 1086 1715 2697 3901 6299 9071 2000 1306 2964 5133 8092 1148 1813 2852 4124 6660 9591

Calculating meter capacity To calculate a volume rate for a given velocity multiply the capacity in this table by the desired at the pressure and divide the answer by 100 Example Determine the hourly flow rate al 70 fps for an 8 inch meter operating at 800 psig Volume =7635 MSCFH Velocity 70 Answer = 763570100 = 5344 MSCFH

Pa~e 3

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 20 F and gas composition These values are intended to be a guide In Contact Daniel nee ring for a application

Flow RateS (IASOFH) Based UppJ1 30 mls Schedule 40) kPag 4 6 8 10 12 16 20 24 30 36 1000 967 2201 3811 6007 8527 1346 2117 3062 4945 7121 1500 1422 3234 5600 8827 1253 1978 3111 4500 7267 1046 2000 1885 4289 7428 1171 1662 2624 4127 5969 9639 1388 2500 2359 5367 9294 1465 2079 3283 5164 7469 1206 1737 3000 2843 6468 1120 1765 2506 3956 6223 9000 1453 2093 3500 3337 7592 1315 2072 2941 4644 7304 1056 1706 2457 4000 3841 8739 1513 2385 3386 5346 8408 1216 1964 2828 4500 4356 9910 171S 2705 3840 6062 9535 1379 2227 3207 5000 4881 1111 1923 3031 4303 6793 1068 1546 2495 3593 5500 5417 1232 2134 3364 4774 7538 1186 1715 2769 3987 6000 5962 1 3702 5255 8297 1305 1887 3048 4389 6500 6517 1483 2568 4047 5745 9070 1427 2063 3332 4798 7000 7082 1611 2790 4398 6243 9856 1550 2242 3621 5214 7500 7656 1742 3016 4754 6748 1065 1676 2424 3914 5636 8000 8238 1874 3246 5116 7262 1146 1803 2608 4212 6065 8500 8828 2009 3478 5482 7782 1229 1932 2795 4513 6499 9000 9425 2144 3713 5853 8308 1312 2063 2984 4818 6939 9500 10028 2281 3951 6227 8839 1396 2195 3175 5127 7382

10000 10636 2420 4190 6604 9375 1480 2328 3367 5437 7830

Flow Rates (IANSOND) Based Upon 30 mls (Scnedule 40) PSIG 4 6 8 10 12 16 20 24 30 36 1000 0232 0528 0915 1442 2046 3231 5082 7350 11869 17091 1500 0341 0776 1344 2119 3007 4748 7468 10801 17441 25116 2000 0453 1029 1783 2810 3989 6297 9904 14325 23133 33311 2500 0566 1288 2231 3516 4991 7879 12393 17924 28946 41682 3000 0682 1552 2688 4237 6014 9495 14935 21600 34882 50230 3500 0801 1821 3155 4973 7059 11145 17530 25354 40943 58958 4000 0922 2097 3632 5725 8126 12830 20179 29186 47131 67869 4500 1045 2378 4119 6492 9215 14549 22883 33097 53447 76963 5000 1171 2664 4615 7275 10326 16302 25641 37086 59889 86240 5500 1300 2957 5121 8072 11459 18091 28454 41154 66458 95699 6000 1431 3254 5637 8885 19912 31319 45298 73150 105336 6500 1564 3557 6162 9713 13787 21767 34236 49517 79964 115148 7000 1700 3866 6696 10555 14982 23653 37203 53808 86893 125126 7500 1837 4179 7239 11410 16196 25570 40218 58168 93934 135265 8000 1977 4497 7789 12278 17428 27515 43277 62592 101078 145553 8500 2119 4819 8347 13157 18676 29485 46376 67075 108318 155978 9000 2262 51 8912 14047 19939 31479 71611 115642 166524 9500 2407 5474 9482 14945 21214 33492 52679 76191 123038 177175

10000 2553 5805 10056 15851 22500 35522 55871 80808 130494 187911

Calculating meter capacity To calculate a volume rate for a given velocity the capacity this table by the desired velocity at the operating pressure and divide the answer 100 Determine the hourly flow rate at 30 mps for an 8 inch meter at 4500 Volume 1716 Velocity 10 Answer 17161030 5719 MSCMH

Product Oata Sheet DAN-GFM-DS-21-rev0404 April 2004

The drawings below represent recommended piping lengths for various flow conditioners when installed with the Daniel SeniorSonic flowmeter If shorter lengths are used there may be an increase in flow measurement uncertainty

Piping Recommendation For SeniorSonic With No Flow Conditioner

1~~--------------------200 -----------------------~

Q----I__------shy~

J ~~f --M-I-middotn-im-~-~-p-iP-i-n-g-R-e-c-o-m-m-e-n-a-a-tl-o-n-F-o-r-S-en-I-o-r-S-o-n-ic-W-it-h-D-a-n-ie-l-p-r-O-fi-le-r-o-r-C-p-~-5-0-E~-F--o-w-c-o-n-d-itl-io-n-e-r--

1 00 middot -2 o~o ~1gt

[ _____ ---Al11~ ----- =ul [II I

I 0 0 a It Minimum Piping Recommendation for Bimiddotdirectional SeniorSonic

with Daniel Profiler or CPA 50E Flow Conditioner

~------- 100 ------t ~------- 100 ----~ - 50---shy

3middot 50

-- 50 ---shy

3middot 50

~ -

A WARNING Do not operate this instrument in excess of the specifications listed Failure to heed this warning could result in serious injury andor damage to the equipment

Page 5

---- - --- _ --- ----------------- -------------------------shy

--iI

-------~~--------1

----~----------------I _____________________I

----~------~----__i _____bullmiddot________ ----__i

____________shy____~__i

____________________---i __________________

_________shy__________~~

~ I ~

I

~

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

8

10

12

16

20

24

30

36 r

ANSI Class 300 600--~------------------------i

900__________----__------__------i 1500

-------------------------------~ Flange Raised Face (RF) _________________-_------j

Ring Type Joint (RTJ)___---------__bull-_____Imiddot

Materials Standard ~----~~--~----~--------~~ Stainless Steel

DJplex --~--------------------------~----~ _________________________--____~__

Device Type

Electronics

Transducers

Meter Size (Inches)

Daniel Ultrasonic Model Number Selections ES-21055 RevW

SeniorSonic (4-Path) ---------------1 JuniorSonic (1~Path) ------------1 JuniorSonic (2-Path) ______________

Mark II UL 24VDC 4-20rlA 3NPT

Mark UL 24VDC 1middot5VDC 3NPT ---------------------1 Mark CENaEC 24V DC 4-20mA M20 --------------_--__1

Mark IICB-JELEC24VDC1-SVDCM20

Mark II ClNELEc 24VDC 4-20mA M20 Rerrote

Mark II CENELEC 24VDC 1-5VDCM20 Rerrote

MarkU UL 24VOC4-20mA 3NPT Rerrote_

Mark II U~ 24VDC l-SVPG 3NPT Rerrote

Mark IIIUL 34 NPT

Mark III UL 34NPT Rerrote

TmiddotSlo T-12

4

middot 6

Page 6

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Systems Daniel Measurement and Control is the industry leader in designing constructing and commissioning of complex oil and gas metering systems to exacting standards

This global organization offers decades of petroleum fiscal flow measurement application experience Customers rely confidently on Daniels Systems Group international fabrication facilities customized engineering and its successes in field-testing and support From the simplest single-stream skid to complex on-site installations Daniel Systems delivers both natural gas and liquid petroleum tumkey applications Daniel Systems designs constructs and commissions the metering project blending up-toshythe-minute technology with decades of understanding what customers need and expect

Components of a Daniel Systems installation typically include meters valves provers flow-control instruments instrumentation and read-out equipment and process management components

Computer software and hardware are integrated with the measurement system Standard calculation methods include AGA3 (now API-MPMS-143) ISO 5167 AGA578 AGA9 and the API Manual for Petroleum Measurement Standards

Daniel DMSS-2000 Supervisory Control Systems utilize a sophisticated Graphical User Interface database server and a dedicated PLC for the metering skidMOV interface Redundancy is often used for custody transfer systems andor when system integrity is essential

A dedicated Project Manager and Project Team are assigned to each measurement system project This team is responsible for overall system design and project construction from start to finish A separate internal QAQC group reviews all design detailS inside and outside fabrication assembly and system testing

Whether it is a pipeline offshore production facility or a loading facility for ocean-going tankers the Daniel Systems group is a proven single-source solution for customers throughout the world

Page 7

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Daniel Measurement Services Daniel Measurement Services takes pride in being there after needs arise with the right solution for customers with gas and liquid fiscal flow measurement applications

Around the clock and around the world Daniel Measurement Services has experienced highly qualified people prepared to help customers who need assistance with the following

middot Start-up and commissioning middot Preventive maintenance middot Product repair I upgrades middot Project management and integration middot Meter Tube inspection and recertification middot Remote diagnostics middot Warranty Plus middot Technical training

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880

Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337

Stirling Scotland - UK Middle East amp Africa T +4401786433400 F +44 01786433401

Singapore - Asia Pacific T +65-6777-8211 F +65-6770-8001

USA Toll Free 1-888-FLOW-001 wwwdanielcom

Daniel is a whOlly owned subsidiary of Emerson Electric Co and a division of Emerson Process Management The Daniel logo is a registered trademark of Daniel Industnes tnc The Emerson logo is a trademark and service mark of Emerson Electric Co Brand mark listing are marks of one of the Emerson Process Management family of companies All other marks are property of their respecl ive owners The Daniel UltraSonic Gas Flow Meter including Mark III electronics is covered by US Patents 598330 and 4646 575 and patents pending The contents of this publication are presented for information purposes only and while effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or thel( use or applicability Daniel does not assume responsibility for the selection use or maintenance of any Daniel product Responsibility for proper selection use and maintenance of any Daniel product remains solely wilh the purchaser and end-userAII sales are governed by our terms and conditions which are available upon request We reserve the right to modify or improve the designs or specification of our products at any time without notice

-- -~J ~~--------- EMERSON bull ~ I

copy2004 Daniel Measurement and Control Inc All rights reserved Printed in the USA DAN -GFM-DS-0221-rev0404

reg DAN-3MT-3M-0801 -~I August 2001_-shy

3 SectioQltandProfiler Meter Tubes ~ Pf~6 5 ~~ IrMimiddot~

Instruments You Can Trust Daniel Meter Tubes are more than just fabricated pipe with an orifice fitting They are accurate dependable instruments because of Daniels dedicated approach to quality Extra steps taken during every phase of meter tube design and production separate Daniel Meter Tubes from all the rest

The Daniel 3 section meter tube is available with any style Senior or Junior orifice fitting Simplex plate holder or orifice flanges The assembly contains an inlet spool of the minimum length prescribed by the 143 standard The second section begins with a concentric flange mounted tube bund=1 leetln9 the 2000 API 143 requirements and a W thick spacer plate to ease tube removal for inspection The 04~r end of section 2 conshytains the orifice flange or fitting The third or downstream section follows and contains 2 branchOonnections and is extra long to allow for the addition of extra branch conshynections in the field If desired The standard meter tube has flanged outer ends Other end connections are avaUable on request

Inspectionffesting= Daniel maintains rigid inspection procedures during manufacturing of meter tubes Micrometer and internal surface roughness readings are recorded and supplied with each meter tUbe Customer or third party inspectors are welcome to verify these readings Radiography of welds is another service that is available

Fabrication Fabrication of your instrument Includes attaching the orifice fitting to the meter tube to make an integral primary measuring element For welding operashytions Daniel uses automatic welding machines and rotatshying positioners Highly skilled code qualified welders are employed to tum out highest quality on each job Special internal jigs and fixtures are used to insure smooth Inlet and outlet surfaces without steps or offsets All welds receive expert grinding by experienced craftsshy

men X

cl

-

gt shy

~

-

J ~

Features bull Dowel pin alignment close tolerance maleffemale

flange or knock out dowel pins insure that the bores of sections two and three are matched without offsets

One 1h and one 0 branch connection on the downstream for thermowell or other uses standard

Beveled flanged or reduced ends as well as any available weld fitting can be furnished on the ends of the tubes

Hydrostatically tested after manufacture

Each orifice fitting is tested for tap hole and orifice plate seal integrity after the meter tube has been pressure tested

Material Selection Daniel uses special cold drawn seamless tubing or honed pipe in the fabrication of meter tubes The strict reqUirements for intemal roundshyness and surface finish preclude the use of standard commercial pipe in most cases Daniel maintains a large inventory of this special pipe to rapidly complete your order

LT

EMERSON~ ltocess Management

~~------------------------------------------------------------~------------------------------

Raised Face Weld neck

NA

3M-30RW

3M-60RW High Pressure

3M-90RW 3M-150RW 3M-250RW

DAN-3MT-3M-0801 August 2001

3 Section Meter Tube Catalog Numbers 2-12 with Senior Fitting 10 amp 12 with Junior Fittina

~

Pressure Rating

150

Flange by Weld

(Flangnek)

3M-011

Flange by Flange

(Flanged)

3M-101

Weld by Weld

(Weldnek)

NA

Flange by Weld

(Flangnek)

3M-021

Flange by Flange

(Flanged)

3M-201

Weld by Weld

(Weldnek)

NA

300 3M-013 3M-103 NA 3M-023 3M-203 NA

600 3M-015 3M-105 3M-185 3M-025 3M-205 3M-285

H~h Pressure 3 Section Meter Tubes 900 3M-016 3M-106 3M-186 3M-026 3M-206 3M-286

1500 3M-017 3M-107 3M-187 3M-027 3M-207 3M-287

2500 3M-018 3M-108 3M-188 3M-028 3M-208 3M-288

2middot8 with Simplex 2middot12 with Orifice Flanges Flange byPressure

WeldRating Weld by Weld (Flangnek) (Weldnek)

150 3M-071 NA 3M-073300 NA

600 3M-075 3M-705 High Pressure

3M-7063M-076900 3M-7071500 3M-077 3M-7083M-0782500 -

Two Section Meter Tubes When Usmg Weldnek Flttmgs

Senior and Simplex fittings are also available in 10000 psi rating in some sizes All units are also available with Ring Type Joint (RTJ) flanges on request Sizes larger than 12 available on request

PackingShipping Daniel bolts together all meter A SPECIAL NOTE The use of factory original Daniel tubes when size permits before shipment This saves parts will assure your Senior Junior and Simplex Orifice the user time and field labor costs Fittings are protectshy fittings will stay within original specifications and operate ed by heavy lumber and the tube flanges by special-cut properly protectors

PaintingCoating The Daniel standard paint is a basic enamel type Special coatings such as multi-coat

offshore systems are available on request

3~Section Meter Tube with Tube Bundle

~-----~ U ----~---------~=~~middotmiddotmiddotmiddot~middot t)middotmiddot-middot ~- - -0bull )00)00 1

I~IC--middotmiddotmiddot-middot -----shyshy-bullmiddotV ------- ~

~ - ~-

~

ii~pound bullbullbull ~

Standard lenAths Size un Upstream 0 Downstream V (vane location)

3 7-5 4-0 130 4 9~~9 4-0 130

6 14-8 5-0 t30

102410 60middot middot 130 1~ +1 2tYS Tq 130 JiIf

Note Straightening vanes are not available in 2line size (See Dald Profller DAN-1852middot 2M)

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Daniel meter tubes can be supshyplied in many combinations and configurations Any of the orifice fittings plate holders or orifice flanges can be included in a meter tube Each 3 section standard meter tube is equipped with a flange mounted tube bundle straightener In accordance with April 2000 API 143 and a 1h thick spacer to facilitate tube removal for inspection Downstreams are longer than minimum required to allow for field Installation of additional branch connections If required

To specify a 3 section meter tube use the designation 3M followed by the type orifice holding deVice Ex 4 600 3 section meter tube with flanged ends using a Senior fitting flangneck style is specified as 4-3M-015 The same unit with a weldneck style Simplex is specified as 4middot3M-705 When ordering specify pipe schedule and end configuration Larger size and custom meter tube designs are available on request

The Daniel Profilertrade three section meter tube is availshy lows and contains 2 branch connections Other or addi able with any style Senior or Junior orifice fitting Simplex tiona I connections can be supplied in this section on plate holder or orifice flanges The assembly contains an request These meter tubes are for use in any piping conshyinlet spool of tile minimum length determined during testshy figuration with beta ratios to 67 Downstream sections ing to the API 143 standard The flange union between are extra long to allow for the addition of extra branch the first and second sections contains the ProfilerN and connections in the field if desired The standard meter a Y2 thick spacer plate to facilitate tube removal for tube has beveled outer ends Flanges or other end conshyinspection The outer end of section 2 contains the orishy nections are available on request fice flange or fitting The third or downstream section fol

Meter Tubes Catalog Numbers - 2 WI emor In9 bull Wit un or Itt ng2 1 th S Fitt 10 amp 12 h J i F i

Pressure Rating

Flange by Weld

(F1angnek)

Flange by Flange

(Flanged)

Weld by Weld

(Weldnek)

Flange by Weld

(Flangnek)

Flange by Flange

(Flanged)

Weld by Weld

(WeJdnek) 150 M011 M-101 NA M-021 M-201 NA 300 M-Q13 M-103 NA M023 M-203

NA 600 M-015 M-105 M-t85 M-025 M-205 M-285

2middot8 with Simplex 2middot12 with Orifice Flanges

Pressure Rating

Flange by Weld

weld by Weld

(Weldnek)CFlananekl 150 M-071 NA 300 M-073 NJA 6QfJ M-()75 M-705

Raised Face Weld Neck

NA - -

lM-30RW M-60RW

Two Section Meter Tube When USing Weldnek Fittings

Consult Factory for High Pressure Applications

PROFILERTM Flow Conditioning Plate

The Profiler has been tested and Shown to be in full compliance with the requirementS of API 143 April 2000 The Profiler both removes swirl

the tube bundle Available In flange mounted model only Also available In RTJ style on request

and creates a fully developed flow profile at the orifice Use of this unit allows shortened upstream straight pipe lengths of 17 diameters Beta ratio limit is 67 as with

-~---

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 11: Medidor de Flujo

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 60 F and gas composition These values are intended to be a guide in Contact Daniel engineering for a specific application

_ Flow Rates (JIISCFHl Basea Upon 100 ftls PSIG 4 6 8 10 12 16 20 24 30 36 100 247 561 971 1532 2174 3432 5398 7807 12607 18154 200 468 1065 1845 2908 4127 6515 10248 14822 23935 34467 300 696 1584 2743 4325 6137 9690 15240 22043 35596 51258 400 931 2118 3668 5782 8206 12955 20377 29472 47593 68534 500 2667 4619 7282 10334 16315 25661 37114 59934 86305 600 1421 3232 5597 8823 12522 19770 31095 44973 72626 104582 700 1676 3813 6602 10409 14772 23322 36682 53055 85677 123374 800 1938 4409 7635 12036 17082 26968 42417 61349 99070 142661 900 2207 5021 8694 13706 19452 30710 48302 69861 112816 162455 1000 2482 5646 9777 15414 21875 34536 54320 78565 126872 182696 1100 2763 6286 10885 17161 24355 38451 60478 87471 141254 203405 1200 3050 6939 12015 18943 26883 42443 66756 96551 155917 224521 1300 3341 7602 13164 20753 29453 46500 73137 105781 170822 245983 1400 3637 8274 14327 22587 32055 50608 79599 115127 185915 267718 1500 3935 8953 15504 24442 34688 54765 86137 124583 201184 289706 1600 4235 9635 16685 26305 37331 58938 92700 134076 216515 311781 1700 4536 10321 17871 28175 39986 63128 99291 143608 231908 333948 1800 4836 11002 19052 30036 42627 67298 105850 153094 247227 356006 1900 5134 11681 20226 31888 45255 71448 112376 162534 262471 377958 2000 5429 12350 21386 33716 47849 75543 118818 171851 277516 399623

Flow Rates (MIfIISCFfJ) Based Upon 100 ffls PSIG 4 6 8 10 12 16 20 24 30 36 100 59 135 233 368 522 824 1295 1874 3026 4357 200 113 256 443 698 990 1564 2459 3557 5744 8272 300 168 380 658 1038 1473 2326 3658 5290 8543 1230 400 224 508 880 1388 1969 3109 4890 7073 1142 1645 600 282 640 110~ 1748 2480 3916 6159 8907 1438 2071 600 342 776 1343 2118 3005 4745 7463 1079 1743 2510 700 403 915 1685 2498 3545 5597 8804 1273 2066 2961 800 466 1058 1832 2889 4100 6472 1018 1472 2378 3424 900 531 1205 2087 3289 4668 7370 1159 1677 2708 3899

1000 597 1355 2346 3699 5250 8289 1304 1886 3045 4385 1100 665 1509 2612 4119 5845 9228 1451 2099 3390 4882 1200 734 1665 2884 4546 6452 1019 1602 2317 3742 5389 1300 804 1824 3159 4981 7069 1116 1755 2539 4100 5904 1400 875 1986 3438 5421 7693 1215 1910 2763 4462 6425 1500 947 2149 3721 5866 8325 1314 2067 2990 4828 6953 1600 1019 2313 4004 6313 8960 1415 2225 3218 5196 7483 1700 1091 2477 4289 6762 9597 1515 2383 3447 5566middot 8015 1800 1164 2641 4572 7209 1023 1615 2540 3674 5933 8544 1900 1235 2803 4854 7653 1086 1715 2697 3901 6299 9071 2000 1306 2964 5133 8092 1148 1813 2852 4124 6660 9591

Calculating meter capacity To calculate a volume rate for a given velocity multiply the capacity in this table by the desired at the pressure and divide the answer by 100 Example Determine the hourly flow rate al 70 fps for an 8 inch meter operating at 800 psig Volume =7635 MSCFH Velocity 70 Answer = 763570100 = 5344 MSCFH

Pa~e 3

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 20 F and gas composition These values are intended to be a guide In Contact Daniel nee ring for a application

Flow RateS (IASOFH) Based UppJ1 30 mls Schedule 40) kPag 4 6 8 10 12 16 20 24 30 36 1000 967 2201 3811 6007 8527 1346 2117 3062 4945 7121 1500 1422 3234 5600 8827 1253 1978 3111 4500 7267 1046 2000 1885 4289 7428 1171 1662 2624 4127 5969 9639 1388 2500 2359 5367 9294 1465 2079 3283 5164 7469 1206 1737 3000 2843 6468 1120 1765 2506 3956 6223 9000 1453 2093 3500 3337 7592 1315 2072 2941 4644 7304 1056 1706 2457 4000 3841 8739 1513 2385 3386 5346 8408 1216 1964 2828 4500 4356 9910 171S 2705 3840 6062 9535 1379 2227 3207 5000 4881 1111 1923 3031 4303 6793 1068 1546 2495 3593 5500 5417 1232 2134 3364 4774 7538 1186 1715 2769 3987 6000 5962 1 3702 5255 8297 1305 1887 3048 4389 6500 6517 1483 2568 4047 5745 9070 1427 2063 3332 4798 7000 7082 1611 2790 4398 6243 9856 1550 2242 3621 5214 7500 7656 1742 3016 4754 6748 1065 1676 2424 3914 5636 8000 8238 1874 3246 5116 7262 1146 1803 2608 4212 6065 8500 8828 2009 3478 5482 7782 1229 1932 2795 4513 6499 9000 9425 2144 3713 5853 8308 1312 2063 2984 4818 6939 9500 10028 2281 3951 6227 8839 1396 2195 3175 5127 7382

10000 10636 2420 4190 6604 9375 1480 2328 3367 5437 7830

Flow Rates (IANSOND) Based Upon 30 mls (Scnedule 40) PSIG 4 6 8 10 12 16 20 24 30 36 1000 0232 0528 0915 1442 2046 3231 5082 7350 11869 17091 1500 0341 0776 1344 2119 3007 4748 7468 10801 17441 25116 2000 0453 1029 1783 2810 3989 6297 9904 14325 23133 33311 2500 0566 1288 2231 3516 4991 7879 12393 17924 28946 41682 3000 0682 1552 2688 4237 6014 9495 14935 21600 34882 50230 3500 0801 1821 3155 4973 7059 11145 17530 25354 40943 58958 4000 0922 2097 3632 5725 8126 12830 20179 29186 47131 67869 4500 1045 2378 4119 6492 9215 14549 22883 33097 53447 76963 5000 1171 2664 4615 7275 10326 16302 25641 37086 59889 86240 5500 1300 2957 5121 8072 11459 18091 28454 41154 66458 95699 6000 1431 3254 5637 8885 19912 31319 45298 73150 105336 6500 1564 3557 6162 9713 13787 21767 34236 49517 79964 115148 7000 1700 3866 6696 10555 14982 23653 37203 53808 86893 125126 7500 1837 4179 7239 11410 16196 25570 40218 58168 93934 135265 8000 1977 4497 7789 12278 17428 27515 43277 62592 101078 145553 8500 2119 4819 8347 13157 18676 29485 46376 67075 108318 155978 9000 2262 51 8912 14047 19939 31479 71611 115642 166524 9500 2407 5474 9482 14945 21214 33492 52679 76191 123038 177175

10000 2553 5805 10056 15851 22500 35522 55871 80808 130494 187911

Calculating meter capacity To calculate a volume rate for a given velocity the capacity this table by the desired velocity at the operating pressure and divide the answer 100 Determine the hourly flow rate at 30 mps for an 8 inch meter at 4500 Volume 1716 Velocity 10 Answer 17161030 5719 MSCMH

Product Oata Sheet DAN-GFM-DS-21-rev0404 April 2004

The drawings below represent recommended piping lengths for various flow conditioners when installed with the Daniel SeniorSonic flowmeter If shorter lengths are used there may be an increase in flow measurement uncertainty

Piping Recommendation For SeniorSonic With No Flow Conditioner

1~~--------------------200 -----------------------~

Q----I__------shy~

J ~~f --M-I-middotn-im-~-~-p-iP-i-n-g-R-e-c-o-m-m-e-n-a-a-tl-o-n-F-o-r-S-en-I-o-r-S-o-n-ic-W-it-h-D-a-n-ie-l-p-r-O-fi-le-r-o-r-C-p-~-5-0-E~-F--o-w-c-o-n-d-itl-io-n-e-r--

1 00 middot -2 o~o ~1gt

[ _____ ---Al11~ ----- =ul [II I

I 0 0 a It Minimum Piping Recommendation for Bimiddotdirectional SeniorSonic

with Daniel Profiler or CPA 50E Flow Conditioner

~------- 100 ------t ~------- 100 ----~ - 50---shy

3middot 50

-- 50 ---shy

3middot 50

~ -

A WARNING Do not operate this instrument in excess of the specifications listed Failure to heed this warning could result in serious injury andor damage to the equipment

Page 5

---- - --- _ --- ----------------- -------------------------shy

--iI

-------~~--------1

----~----------------I _____________________I

----~------~----__i _____bullmiddot________ ----__i

____________shy____~__i

____________________---i __________________

_________shy__________~~

~ I ~

I

~

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

8

10

12

16

20

24

30

36 r

ANSI Class 300 600--~------------------------i

900__________----__------__------i 1500

-------------------------------~ Flange Raised Face (RF) _________________-_------j

Ring Type Joint (RTJ)___---------__bull-_____Imiddot

Materials Standard ~----~~--~----~--------~~ Stainless Steel

DJplex --~--------------------------~----~ _________________________--____~__

Device Type

Electronics

Transducers

Meter Size (Inches)

Daniel Ultrasonic Model Number Selections ES-21055 RevW

SeniorSonic (4-Path) ---------------1 JuniorSonic (1~Path) ------------1 JuniorSonic (2-Path) ______________

Mark II UL 24VDC 4-20rlA 3NPT

Mark UL 24VDC 1middot5VDC 3NPT ---------------------1 Mark CENaEC 24V DC 4-20mA M20 --------------_--__1

Mark IICB-JELEC24VDC1-SVDCM20

Mark II ClNELEc 24VDC 4-20mA M20 Rerrote

Mark II CENELEC 24VDC 1-5VDCM20 Rerrote

MarkU UL 24VOC4-20mA 3NPT Rerrote_

Mark II U~ 24VDC l-SVPG 3NPT Rerrote

Mark IIIUL 34 NPT

Mark III UL 34NPT Rerrote

TmiddotSlo T-12

4

middot 6

Page 6

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Systems Daniel Measurement and Control is the industry leader in designing constructing and commissioning of complex oil and gas metering systems to exacting standards

This global organization offers decades of petroleum fiscal flow measurement application experience Customers rely confidently on Daniels Systems Group international fabrication facilities customized engineering and its successes in field-testing and support From the simplest single-stream skid to complex on-site installations Daniel Systems delivers both natural gas and liquid petroleum tumkey applications Daniel Systems designs constructs and commissions the metering project blending up-toshythe-minute technology with decades of understanding what customers need and expect

Components of a Daniel Systems installation typically include meters valves provers flow-control instruments instrumentation and read-out equipment and process management components

Computer software and hardware are integrated with the measurement system Standard calculation methods include AGA3 (now API-MPMS-143) ISO 5167 AGA578 AGA9 and the API Manual for Petroleum Measurement Standards

Daniel DMSS-2000 Supervisory Control Systems utilize a sophisticated Graphical User Interface database server and a dedicated PLC for the metering skidMOV interface Redundancy is often used for custody transfer systems andor when system integrity is essential

A dedicated Project Manager and Project Team are assigned to each measurement system project This team is responsible for overall system design and project construction from start to finish A separate internal QAQC group reviews all design detailS inside and outside fabrication assembly and system testing

Whether it is a pipeline offshore production facility or a loading facility for ocean-going tankers the Daniel Systems group is a proven single-source solution for customers throughout the world

Page 7

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Daniel Measurement Services Daniel Measurement Services takes pride in being there after needs arise with the right solution for customers with gas and liquid fiscal flow measurement applications

Around the clock and around the world Daniel Measurement Services has experienced highly qualified people prepared to help customers who need assistance with the following

middot Start-up and commissioning middot Preventive maintenance middot Product repair I upgrades middot Project management and integration middot Meter Tube inspection and recertification middot Remote diagnostics middot Warranty Plus middot Technical training

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880

Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337

Stirling Scotland - UK Middle East amp Africa T +4401786433400 F +44 01786433401

Singapore - Asia Pacific T +65-6777-8211 F +65-6770-8001

USA Toll Free 1-888-FLOW-001 wwwdanielcom

Daniel is a whOlly owned subsidiary of Emerson Electric Co and a division of Emerson Process Management The Daniel logo is a registered trademark of Daniel Industnes tnc The Emerson logo is a trademark and service mark of Emerson Electric Co Brand mark listing are marks of one of the Emerson Process Management family of companies All other marks are property of their respecl ive owners The Daniel UltraSonic Gas Flow Meter including Mark III electronics is covered by US Patents 598330 and 4646 575 and patents pending The contents of this publication are presented for information purposes only and while effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or thel( use or applicability Daniel does not assume responsibility for the selection use or maintenance of any Daniel product Responsibility for proper selection use and maintenance of any Daniel product remains solely wilh the purchaser and end-userAII sales are governed by our terms and conditions which are available upon request We reserve the right to modify or improve the designs or specification of our products at any time without notice

-- -~J ~~--------- EMERSON bull ~ I

copy2004 Daniel Measurement and Control Inc All rights reserved Printed in the USA DAN -GFM-DS-0221-rev0404

reg DAN-3MT-3M-0801 -~I August 2001_-shy

3 SectioQltandProfiler Meter Tubes ~ Pf~6 5 ~~ IrMimiddot~

Instruments You Can Trust Daniel Meter Tubes are more than just fabricated pipe with an orifice fitting They are accurate dependable instruments because of Daniels dedicated approach to quality Extra steps taken during every phase of meter tube design and production separate Daniel Meter Tubes from all the rest

The Daniel 3 section meter tube is available with any style Senior or Junior orifice fitting Simplex plate holder or orifice flanges The assembly contains an inlet spool of the minimum length prescribed by the 143 standard The second section begins with a concentric flange mounted tube bund=1 leetln9 the 2000 API 143 requirements and a W thick spacer plate to ease tube removal for inspection The 04~r end of section 2 conshytains the orifice flange or fitting The third or downstream section follows and contains 2 branchOonnections and is extra long to allow for the addition of extra branch conshynections in the field If desired The standard meter tube has flanged outer ends Other end connections are avaUable on request

Inspectionffesting= Daniel maintains rigid inspection procedures during manufacturing of meter tubes Micrometer and internal surface roughness readings are recorded and supplied with each meter tUbe Customer or third party inspectors are welcome to verify these readings Radiography of welds is another service that is available

Fabrication Fabrication of your instrument Includes attaching the orifice fitting to the meter tube to make an integral primary measuring element For welding operashytions Daniel uses automatic welding machines and rotatshying positioners Highly skilled code qualified welders are employed to tum out highest quality on each job Special internal jigs and fixtures are used to insure smooth Inlet and outlet surfaces without steps or offsets All welds receive expert grinding by experienced craftsshy

men X

cl

-

gt shy

~

-

J ~

Features bull Dowel pin alignment close tolerance maleffemale

flange or knock out dowel pins insure that the bores of sections two and three are matched without offsets

One 1h and one 0 branch connection on the downstream for thermowell or other uses standard

Beveled flanged or reduced ends as well as any available weld fitting can be furnished on the ends of the tubes

Hydrostatically tested after manufacture

Each orifice fitting is tested for tap hole and orifice plate seal integrity after the meter tube has been pressure tested

Material Selection Daniel uses special cold drawn seamless tubing or honed pipe in the fabrication of meter tubes The strict reqUirements for intemal roundshyness and surface finish preclude the use of standard commercial pipe in most cases Daniel maintains a large inventory of this special pipe to rapidly complete your order

LT

EMERSON~ ltocess Management

~~------------------------------------------------------------~------------------------------

Raised Face Weld neck

NA

3M-30RW

3M-60RW High Pressure

3M-90RW 3M-150RW 3M-250RW

DAN-3MT-3M-0801 August 2001

3 Section Meter Tube Catalog Numbers 2-12 with Senior Fitting 10 amp 12 with Junior Fittina

~

Pressure Rating

150

Flange by Weld

(Flangnek)

3M-011

Flange by Flange

(Flanged)

3M-101

Weld by Weld

(Weldnek)

NA

Flange by Weld

(Flangnek)

3M-021

Flange by Flange

(Flanged)

3M-201

Weld by Weld

(Weldnek)

NA

300 3M-013 3M-103 NA 3M-023 3M-203 NA

600 3M-015 3M-105 3M-185 3M-025 3M-205 3M-285

H~h Pressure 3 Section Meter Tubes 900 3M-016 3M-106 3M-186 3M-026 3M-206 3M-286

1500 3M-017 3M-107 3M-187 3M-027 3M-207 3M-287

2500 3M-018 3M-108 3M-188 3M-028 3M-208 3M-288

2middot8 with Simplex 2middot12 with Orifice Flanges Flange byPressure

WeldRating Weld by Weld (Flangnek) (Weldnek)

150 3M-071 NA 3M-073300 NA

600 3M-075 3M-705 High Pressure

3M-7063M-076900 3M-7071500 3M-077 3M-7083M-0782500 -

Two Section Meter Tubes When Usmg Weldnek Flttmgs

Senior and Simplex fittings are also available in 10000 psi rating in some sizes All units are also available with Ring Type Joint (RTJ) flanges on request Sizes larger than 12 available on request

PackingShipping Daniel bolts together all meter A SPECIAL NOTE The use of factory original Daniel tubes when size permits before shipment This saves parts will assure your Senior Junior and Simplex Orifice the user time and field labor costs Fittings are protectshy fittings will stay within original specifications and operate ed by heavy lumber and the tube flanges by special-cut properly protectors

PaintingCoating The Daniel standard paint is a basic enamel type Special coatings such as multi-coat

offshore systems are available on request

3~Section Meter Tube with Tube Bundle

~-----~ U ----~---------~=~~middotmiddotmiddotmiddot~middot t)middotmiddot-middot ~- - -0bull )00)00 1

I~IC--middotmiddotmiddot-middot -----shyshy-bullmiddotV ------- ~

~ - ~-

~

ii~pound bullbullbull ~

Standard lenAths Size un Upstream 0 Downstream V (vane location)

3 7-5 4-0 130 4 9~~9 4-0 130

6 14-8 5-0 t30

102410 60middot middot 130 1~ +1 2tYS Tq 130 JiIf

Note Straightening vanes are not available in 2line size (See Dald Profller DAN-1852middot 2M)

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Daniel meter tubes can be supshyplied in many combinations and configurations Any of the orifice fittings plate holders or orifice flanges can be included in a meter tube Each 3 section standard meter tube is equipped with a flange mounted tube bundle straightener In accordance with April 2000 API 143 and a 1h thick spacer to facilitate tube removal for inspection Downstreams are longer than minimum required to allow for field Installation of additional branch connections If required

To specify a 3 section meter tube use the designation 3M followed by the type orifice holding deVice Ex 4 600 3 section meter tube with flanged ends using a Senior fitting flangneck style is specified as 4-3M-015 The same unit with a weldneck style Simplex is specified as 4middot3M-705 When ordering specify pipe schedule and end configuration Larger size and custom meter tube designs are available on request

The Daniel Profilertrade three section meter tube is availshy lows and contains 2 branch connections Other or addi able with any style Senior or Junior orifice fitting Simplex tiona I connections can be supplied in this section on plate holder or orifice flanges The assembly contains an request These meter tubes are for use in any piping conshyinlet spool of tile minimum length determined during testshy figuration with beta ratios to 67 Downstream sections ing to the API 143 standard The flange union between are extra long to allow for the addition of extra branch the first and second sections contains the ProfilerN and connections in the field if desired The standard meter a Y2 thick spacer plate to facilitate tube removal for tube has beveled outer ends Flanges or other end conshyinspection The outer end of section 2 contains the orishy nections are available on request fice flange or fitting The third or downstream section fol

Meter Tubes Catalog Numbers - 2 WI emor In9 bull Wit un or Itt ng2 1 th S Fitt 10 amp 12 h J i F i

Pressure Rating

Flange by Weld

(F1angnek)

Flange by Flange

(Flanged)

Weld by Weld

(Weldnek)

Flange by Weld

(Flangnek)

Flange by Flange

(Flanged)

Weld by Weld

(WeJdnek) 150 M011 M-101 NA M-021 M-201 NA 300 M-Q13 M-103 NA M023 M-203

NA 600 M-015 M-105 M-t85 M-025 M-205 M-285

2middot8 with Simplex 2middot12 with Orifice Flanges

Pressure Rating

Flange by Weld

weld by Weld

(Weldnek)CFlananekl 150 M-071 NA 300 M-073 NJA 6QfJ M-()75 M-705

Raised Face Weld Neck

NA - -

lM-30RW M-60RW

Two Section Meter Tube When USing Weldnek Fittings

Consult Factory for High Pressure Applications

PROFILERTM Flow Conditioning Plate

The Profiler has been tested and Shown to be in full compliance with the requirementS of API 143 April 2000 The Profiler both removes swirl

the tube bundle Available In flange mounted model only Also available In RTJ style on request

and creates a fully developed flow profile at the orifice Use of this unit allows shortened upstream straight pipe lengths of 17 diameters Beta ratio limit is 67 as with

-~---

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 12: Medidor de Flujo

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Selection of meter size These tables can be used to determine the flow range at reference conditions for meters 4 inches to 36 inches All calculations are based on 20 F and gas composition These values are intended to be a guide In Contact Daniel nee ring for a application

Flow RateS (IASOFH) Based UppJ1 30 mls Schedule 40) kPag 4 6 8 10 12 16 20 24 30 36 1000 967 2201 3811 6007 8527 1346 2117 3062 4945 7121 1500 1422 3234 5600 8827 1253 1978 3111 4500 7267 1046 2000 1885 4289 7428 1171 1662 2624 4127 5969 9639 1388 2500 2359 5367 9294 1465 2079 3283 5164 7469 1206 1737 3000 2843 6468 1120 1765 2506 3956 6223 9000 1453 2093 3500 3337 7592 1315 2072 2941 4644 7304 1056 1706 2457 4000 3841 8739 1513 2385 3386 5346 8408 1216 1964 2828 4500 4356 9910 171S 2705 3840 6062 9535 1379 2227 3207 5000 4881 1111 1923 3031 4303 6793 1068 1546 2495 3593 5500 5417 1232 2134 3364 4774 7538 1186 1715 2769 3987 6000 5962 1 3702 5255 8297 1305 1887 3048 4389 6500 6517 1483 2568 4047 5745 9070 1427 2063 3332 4798 7000 7082 1611 2790 4398 6243 9856 1550 2242 3621 5214 7500 7656 1742 3016 4754 6748 1065 1676 2424 3914 5636 8000 8238 1874 3246 5116 7262 1146 1803 2608 4212 6065 8500 8828 2009 3478 5482 7782 1229 1932 2795 4513 6499 9000 9425 2144 3713 5853 8308 1312 2063 2984 4818 6939 9500 10028 2281 3951 6227 8839 1396 2195 3175 5127 7382

10000 10636 2420 4190 6604 9375 1480 2328 3367 5437 7830

Flow Rates (IANSOND) Based Upon 30 mls (Scnedule 40) PSIG 4 6 8 10 12 16 20 24 30 36 1000 0232 0528 0915 1442 2046 3231 5082 7350 11869 17091 1500 0341 0776 1344 2119 3007 4748 7468 10801 17441 25116 2000 0453 1029 1783 2810 3989 6297 9904 14325 23133 33311 2500 0566 1288 2231 3516 4991 7879 12393 17924 28946 41682 3000 0682 1552 2688 4237 6014 9495 14935 21600 34882 50230 3500 0801 1821 3155 4973 7059 11145 17530 25354 40943 58958 4000 0922 2097 3632 5725 8126 12830 20179 29186 47131 67869 4500 1045 2378 4119 6492 9215 14549 22883 33097 53447 76963 5000 1171 2664 4615 7275 10326 16302 25641 37086 59889 86240 5500 1300 2957 5121 8072 11459 18091 28454 41154 66458 95699 6000 1431 3254 5637 8885 19912 31319 45298 73150 105336 6500 1564 3557 6162 9713 13787 21767 34236 49517 79964 115148 7000 1700 3866 6696 10555 14982 23653 37203 53808 86893 125126 7500 1837 4179 7239 11410 16196 25570 40218 58168 93934 135265 8000 1977 4497 7789 12278 17428 27515 43277 62592 101078 145553 8500 2119 4819 8347 13157 18676 29485 46376 67075 108318 155978 9000 2262 51 8912 14047 19939 31479 71611 115642 166524 9500 2407 5474 9482 14945 21214 33492 52679 76191 123038 177175

10000 2553 5805 10056 15851 22500 35522 55871 80808 130494 187911

Calculating meter capacity To calculate a volume rate for a given velocity the capacity this table by the desired velocity at the operating pressure and divide the answer 100 Determine the hourly flow rate at 30 mps for an 8 inch meter at 4500 Volume 1716 Velocity 10 Answer 17161030 5719 MSCMH

Product Oata Sheet DAN-GFM-DS-21-rev0404 April 2004

The drawings below represent recommended piping lengths for various flow conditioners when installed with the Daniel SeniorSonic flowmeter If shorter lengths are used there may be an increase in flow measurement uncertainty

Piping Recommendation For SeniorSonic With No Flow Conditioner

1~~--------------------200 -----------------------~

Q----I__------shy~

J ~~f --M-I-middotn-im-~-~-p-iP-i-n-g-R-e-c-o-m-m-e-n-a-a-tl-o-n-F-o-r-S-en-I-o-r-S-o-n-ic-W-it-h-D-a-n-ie-l-p-r-O-fi-le-r-o-r-C-p-~-5-0-E~-F--o-w-c-o-n-d-itl-io-n-e-r--

1 00 middot -2 o~o ~1gt

[ _____ ---Al11~ ----- =ul [II I

I 0 0 a It Minimum Piping Recommendation for Bimiddotdirectional SeniorSonic

with Daniel Profiler or CPA 50E Flow Conditioner

~------- 100 ------t ~------- 100 ----~ - 50---shy

3middot 50

-- 50 ---shy

3middot 50

~ -

A WARNING Do not operate this instrument in excess of the specifications listed Failure to heed this warning could result in serious injury andor damage to the equipment

Page 5

---- - --- _ --- ----------------- -------------------------shy

--iI

-------~~--------1

----~----------------I _____________________I

----~------~----__i _____bullmiddot________ ----__i

____________shy____~__i

____________________---i __________________

_________shy__________~~

~ I ~

I

~

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

8

10

12

16

20

24

30

36 r

ANSI Class 300 600--~------------------------i

900__________----__------__------i 1500

-------------------------------~ Flange Raised Face (RF) _________________-_------j

Ring Type Joint (RTJ)___---------__bull-_____Imiddot

Materials Standard ~----~~--~----~--------~~ Stainless Steel

DJplex --~--------------------------~----~ _________________________--____~__

Device Type

Electronics

Transducers

Meter Size (Inches)

Daniel Ultrasonic Model Number Selections ES-21055 RevW

SeniorSonic (4-Path) ---------------1 JuniorSonic (1~Path) ------------1 JuniorSonic (2-Path) ______________

Mark II UL 24VDC 4-20rlA 3NPT

Mark UL 24VDC 1middot5VDC 3NPT ---------------------1 Mark CENaEC 24V DC 4-20mA M20 --------------_--__1

Mark IICB-JELEC24VDC1-SVDCM20

Mark II ClNELEc 24VDC 4-20mA M20 Rerrote

Mark II CENELEC 24VDC 1-5VDCM20 Rerrote

MarkU UL 24VOC4-20mA 3NPT Rerrote_

Mark II U~ 24VDC l-SVPG 3NPT Rerrote

Mark IIIUL 34 NPT

Mark III UL 34NPT Rerrote

TmiddotSlo T-12

4

middot 6

Page 6

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Systems Daniel Measurement and Control is the industry leader in designing constructing and commissioning of complex oil and gas metering systems to exacting standards

This global organization offers decades of petroleum fiscal flow measurement application experience Customers rely confidently on Daniels Systems Group international fabrication facilities customized engineering and its successes in field-testing and support From the simplest single-stream skid to complex on-site installations Daniel Systems delivers both natural gas and liquid petroleum tumkey applications Daniel Systems designs constructs and commissions the metering project blending up-toshythe-minute technology with decades of understanding what customers need and expect

Components of a Daniel Systems installation typically include meters valves provers flow-control instruments instrumentation and read-out equipment and process management components

Computer software and hardware are integrated with the measurement system Standard calculation methods include AGA3 (now API-MPMS-143) ISO 5167 AGA578 AGA9 and the API Manual for Petroleum Measurement Standards

Daniel DMSS-2000 Supervisory Control Systems utilize a sophisticated Graphical User Interface database server and a dedicated PLC for the metering skidMOV interface Redundancy is often used for custody transfer systems andor when system integrity is essential

A dedicated Project Manager and Project Team are assigned to each measurement system project This team is responsible for overall system design and project construction from start to finish A separate internal QAQC group reviews all design detailS inside and outside fabrication assembly and system testing

Whether it is a pipeline offshore production facility or a loading facility for ocean-going tankers the Daniel Systems group is a proven single-source solution for customers throughout the world

Page 7

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Daniel Measurement Services Daniel Measurement Services takes pride in being there after needs arise with the right solution for customers with gas and liquid fiscal flow measurement applications

Around the clock and around the world Daniel Measurement Services has experienced highly qualified people prepared to help customers who need assistance with the following

middot Start-up and commissioning middot Preventive maintenance middot Product repair I upgrades middot Project management and integration middot Meter Tube inspection and recertification middot Remote diagnostics middot Warranty Plus middot Technical training

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880

Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337

Stirling Scotland - UK Middle East amp Africa T +4401786433400 F +44 01786433401

Singapore - Asia Pacific T +65-6777-8211 F +65-6770-8001

USA Toll Free 1-888-FLOW-001 wwwdanielcom

Daniel is a whOlly owned subsidiary of Emerson Electric Co and a division of Emerson Process Management The Daniel logo is a registered trademark of Daniel Industnes tnc The Emerson logo is a trademark and service mark of Emerson Electric Co Brand mark listing are marks of one of the Emerson Process Management family of companies All other marks are property of their respecl ive owners The Daniel UltraSonic Gas Flow Meter including Mark III electronics is covered by US Patents 598330 and 4646 575 and patents pending The contents of this publication are presented for information purposes only and while effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or thel( use or applicability Daniel does not assume responsibility for the selection use or maintenance of any Daniel product Responsibility for proper selection use and maintenance of any Daniel product remains solely wilh the purchaser and end-userAII sales are governed by our terms and conditions which are available upon request We reserve the right to modify or improve the designs or specification of our products at any time without notice

-- -~J ~~--------- EMERSON bull ~ I

copy2004 Daniel Measurement and Control Inc All rights reserved Printed in the USA DAN -GFM-DS-0221-rev0404

reg DAN-3MT-3M-0801 -~I August 2001_-shy

3 SectioQltandProfiler Meter Tubes ~ Pf~6 5 ~~ IrMimiddot~

Instruments You Can Trust Daniel Meter Tubes are more than just fabricated pipe with an orifice fitting They are accurate dependable instruments because of Daniels dedicated approach to quality Extra steps taken during every phase of meter tube design and production separate Daniel Meter Tubes from all the rest

The Daniel 3 section meter tube is available with any style Senior or Junior orifice fitting Simplex plate holder or orifice flanges The assembly contains an inlet spool of the minimum length prescribed by the 143 standard The second section begins with a concentric flange mounted tube bund=1 leetln9 the 2000 API 143 requirements and a W thick spacer plate to ease tube removal for inspection The 04~r end of section 2 conshytains the orifice flange or fitting The third or downstream section follows and contains 2 branchOonnections and is extra long to allow for the addition of extra branch conshynections in the field If desired The standard meter tube has flanged outer ends Other end connections are avaUable on request

Inspectionffesting= Daniel maintains rigid inspection procedures during manufacturing of meter tubes Micrometer and internal surface roughness readings are recorded and supplied with each meter tUbe Customer or third party inspectors are welcome to verify these readings Radiography of welds is another service that is available

Fabrication Fabrication of your instrument Includes attaching the orifice fitting to the meter tube to make an integral primary measuring element For welding operashytions Daniel uses automatic welding machines and rotatshying positioners Highly skilled code qualified welders are employed to tum out highest quality on each job Special internal jigs and fixtures are used to insure smooth Inlet and outlet surfaces without steps or offsets All welds receive expert grinding by experienced craftsshy

men X

cl

-

gt shy

~

-

J ~

Features bull Dowel pin alignment close tolerance maleffemale

flange or knock out dowel pins insure that the bores of sections two and three are matched without offsets

One 1h and one 0 branch connection on the downstream for thermowell or other uses standard

Beveled flanged or reduced ends as well as any available weld fitting can be furnished on the ends of the tubes

Hydrostatically tested after manufacture

Each orifice fitting is tested for tap hole and orifice plate seal integrity after the meter tube has been pressure tested

Material Selection Daniel uses special cold drawn seamless tubing or honed pipe in the fabrication of meter tubes The strict reqUirements for intemal roundshyness and surface finish preclude the use of standard commercial pipe in most cases Daniel maintains a large inventory of this special pipe to rapidly complete your order

LT

EMERSON~ ltocess Management

~~------------------------------------------------------------~------------------------------

Raised Face Weld neck

NA

3M-30RW

3M-60RW High Pressure

3M-90RW 3M-150RW 3M-250RW

DAN-3MT-3M-0801 August 2001

3 Section Meter Tube Catalog Numbers 2-12 with Senior Fitting 10 amp 12 with Junior Fittina

~

Pressure Rating

150

Flange by Weld

(Flangnek)

3M-011

Flange by Flange

(Flanged)

3M-101

Weld by Weld

(Weldnek)

NA

Flange by Weld

(Flangnek)

3M-021

Flange by Flange

(Flanged)

3M-201

Weld by Weld

(Weldnek)

NA

300 3M-013 3M-103 NA 3M-023 3M-203 NA

600 3M-015 3M-105 3M-185 3M-025 3M-205 3M-285

H~h Pressure 3 Section Meter Tubes 900 3M-016 3M-106 3M-186 3M-026 3M-206 3M-286

1500 3M-017 3M-107 3M-187 3M-027 3M-207 3M-287

2500 3M-018 3M-108 3M-188 3M-028 3M-208 3M-288

2middot8 with Simplex 2middot12 with Orifice Flanges Flange byPressure

WeldRating Weld by Weld (Flangnek) (Weldnek)

150 3M-071 NA 3M-073300 NA

600 3M-075 3M-705 High Pressure

3M-7063M-076900 3M-7071500 3M-077 3M-7083M-0782500 -

Two Section Meter Tubes When Usmg Weldnek Flttmgs

Senior and Simplex fittings are also available in 10000 psi rating in some sizes All units are also available with Ring Type Joint (RTJ) flanges on request Sizes larger than 12 available on request

PackingShipping Daniel bolts together all meter A SPECIAL NOTE The use of factory original Daniel tubes when size permits before shipment This saves parts will assure your Senior Junior and Simplex Orifice the user time and field labor costs Fittings are protectshy fittings will stay within original specifications and operate ed by heavy lumber and the tube flanges by special-cut properly protectors

PaintingCoating The Daniel standard paint is a basic enamel type Special coatings such as multi-coat

offshore systems are available on request

3~Section Meter Tube with Tube Bundle

~-----~ U ----~---------~=~~middotmiddotmiddotmiddot~middot t)middotmiddot-middot ~- - -0bull )00)00 1

I~IC--middotmiddotmiddot-middot -----shyshy-bullmiddotV ------- ~

~ - ~-

~

ii~pound bullbullbull ~

Standard lenAths Size un Upstream 0 Downstream V (vane location)

3 7-5 4-0 130 4 9~~9 4-0 130

6 14-8 5-0 t30

102410 60middot middot 130 1~ +1 2tYS Tq 130 JiIf

Note Straightening vanes are not available in 2line size (See Dald Profller DAN-1852middot 2M)

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Daniel meter tubes can be supshyplied in many combinations and configurations Any of the orifice fittings plate holders or orifice flanges can be included in a meter tube Each 3 section standard meter tube is equipped with a flange mounted tube bundle straightener In accordance with April 2000 API 143 and a 1h thick spacer to facilitate tube removal for inspection Downstreams are longer than minimum required to allow for field Installation of additional branch connections If required

To specify a 3 section meter tube use the designation 3M followed by the type orifice holding deVice Ex 4 600 3 section meter tube with flanged ends using a Senior fitting flangneck style is specified as 4-3M-015 The same unit with a weldneck style Simplex is specified as 4middot3M-705 When ordering specify pipe schedule and end configuration Larger size and custom meter tube designs are available on request

The Daniel Profilertrade three section meter tube is availshy lows and contains 2 branch connections Other or addi able with any style Senior or Junior orifice fitting Simplex tiona I connections can be supplied in this section on plate holder or orifice flanges The assembly contains an request These meter tubes are for use in any piping conshyinlet spool of tile minimum length determined during testshy figuration with beta ratios to 67 Downstream sections ing to the API 143 standard The flange union between are extra long to allow for the addition of extra branch the first and second sections contains the ProfilerN and connections in the field if desired The standard meter a Y2 thick spacer plate to facilitate tube removal for tube has beveled outer ends Flanges or other end conshyinspection The outer end of section 2 contains the orishy nections are available on request fice flange or fitting The third or downstream section fol

Meter Tubes Catalog Numbers - 2 WI emor In9 bull Wit un or Itt ng2 1 th S Fitt 10 amp 12 h J i F i

Pressure Rating

Flange by Weld

(F1angnek)

Flange by Flange

(Flanged)

Weld by Weld

(Weldnek)

Flange by Weld

(Flangnek)

Flange by Flange

(Flanged)

Weld by Weld

(WeJdnek) 150 M011 M-101 NA M-021 M-201 NA 300 M-Q13 M-103 NA M023 M-203

NA 600 M-015 M-105 M-t85 M-025 M-205 M-285

2middot8 with Simplex 2middot12 with Orifice Flanges

Pressure Rating

Flange by Weld

weld by Weld

(Weldnek)CFlananekl 150 M-071 NA 300 M-073 NJA 6QfJ M-()75 M-705

Raised Face Weld Neck

NA - -

lM-30RW M-60RW

Two Section Meter Tube When USing Weldnek Fittings

Consult Factory for High Pressure Applications

PROFILERTM Flow Conditioning Plate

The Profiler has been tested and Shown to be in full compliance with the requirementS of API 143 April 2000 The Profiler both removes swirl

the tube bundle Available In flange mounted model only Also available In RTJ style on request

and creates a fully developed flow profile at the orifice Use of this unit allows shortened upstream straight pipe lengths of 17 diameters Beta ratio limit is 67 as with

-~---

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 13: Medidor de Flujo

Product Oata Sheet DAN-GFM-DS-21-rev0404 April 2004

The drawings below represent recommended piping lengths for various flow conditioners when installed with the Daniel SeniorSonic flowmeter If shorter lengths are used there may be an increase in flow measurement uncertainty

Piping Recommendation For SeniorSonic With No Flow Conditioner

1~~--------------------200 -----------------------~

Q----I__------shy~

J ~~f --M-I-middotn-im-~-~-p-iP-i-n-g-R-e-c-o-m-m-e-n-a-a-tl-o-n-F-o-r-S-en-I-o-r-S-o-n-ic-W-it-h-D-a-n-ie-l-p-r-O-fi-le-r-o-r-C-p-~-5-0-E~-F--o-w-c-o-n-d-itl-io-n-e-r--

1 00 middot -2 o~o ~1gt

[ _____ ---Al11~ ----- =ul [II I

I 0 0 a It Minimum Piping Recommendation for Bimiddotdirectional SeniorSonic

with Daniel Profiler or CPA 50E Flow Conditioner

~------- 100 ------t ~------- 100 ----~ - 50---shy

3middot 50

-- 50 ---shy

3middot 50

~ -

A WARNING Do not operate this instrument in excess of the specifications listed Failure to heed this warning could result in serious injury andor damage to the equipment

Page 5

---- - --- _ --- ----------------- -------------------------shy

--iI

-------~~--------1

----~----------------I _____________________I

----~------~----__i _____bullmiddot________ ----__i

____________shy____~__i

____________________---i __________________

_________shy__________~~

~ I ~

I

~

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

8

10

12

16

20

24

30

36 r

ANSI Class 300 600--~------------------------i

900__________----__------__------i 1500

-------------------------------~ Flange Raised Face (RF) _________________-_------j

Ring Type Joint (RTJ)___---------__bull-_____Imiddot

Materials Standard ~----~~--~----~--------~~ Stainless Steel

DJplex --~--------------------------~----~ _________________________--____~__

Device Type

Electronics

Transducers

Meter Size (Inches)

Daniel Ultrasonic Model Number Selections ES-21055 RevW

SeniorSonic (4-Path) ---------------1 JuniorSonic (1~Path) ------------1 JuniorSonic (2-Path) ______________

Mark II UL 24VDC 4-20rlA 3NPT

Mark UL 24VDC 1middot5VDC 3NPT ---------------------1 Mark CENaEC 24V DC 4-20mA M20 --------------_--__1

Mark IICB-JELEC24VDC1-SVDCM20

Mark II ClNELEc 24VDC 4-20mA M20 Rerrote

Mark II CENELEC 24VDC 1-5VDCM20 Rerrote

MarkU UL 24VOC4-20mA 3NPT Rerrote_

Mark II U~ 24VDC l-SVPG 3NPT Rerrote

Mark IIIUL 34 NPT

Mark III UL 34NPT Rerrote

TmiddotSlo T-12

4

middot 6

Page 6

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Systems Daniel Measurement and Control is the industry leader in designing constructing and commissioning of complex oil and gas metering systems to exacting standards

This global organization offers decades of petroleum fiscal flow measurement application experience Customers rely confidently on Daniels Systems Group international fabrication facilities customized engineering and its successes in field-testing and support From the simplest single-stream skid to complex on-site installations Daniel Systems delivers both natural gas and liquid petroleum tumkey applications Daniel Systems designs constructs and commissions the metering project blending up-toshythe-minute technology with decades of understanding what customers need and expect

Components of a Daniel Systems installation typically include meters valves provers flow-control instruments instrumentation and read-out equipment and process management components

Computer software and hardware are integrated with the measurement system Standard calculation methods include AGA3 (now API-MPMS-143) ISO 5167 AGA578 AGA9 and the API Manual for Petroleum Measurement Standards

Daniel DMSS-2000 Supervisory Control Systems utilize a sophisticated Graphical User Interface database server and a dedicated PLC for the metering skidMOV interface Redundancy is often used for custody transfer systems andor when system integrity is essential

A dedicated Project Manager and Project Team are assigned to each measurement system project This team is responsible for overall system design and project construction from start to finish A separate internal QAQC group reviews all design detailS inside and outside fabrication assembly and system testing

Whether it is a pipeline offshore production facility or a loading facility for ocean-going tankers the Daniel Systems group is a proven single-source solution for customers throughout the world

Page 7

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Daniel Measurement Services Daniel Measurement Services takes pride in being there after needs arise with the right solution for customers with gas and liquid fiscal flow measurement applications

Around the clock and around the world Daniel Measurement Services has experienced highly qualified people prepared to help customers who need assistance with the following

middot Start-up and commissioning middot Preventive maintenance middot Product repair I upgrades middot Project management and integration middot Meter Tube inspection and recertification middot Remote diagnostics middot Warranty Plus middot Technical training

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880

Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337

Stirling Scotland - UK Middle East amp Africa T +4401786433400 F +44 01786433401

Singapore - Asia Pacific T +65-6777-8211 F +65-6770-8001

USA Toll Free 1-888-FLOW-001 wwwdanielcom

Daniel is a whOlly owned subsidiary of Emerson Electric Co and a division of Emerson Process Management The Daniel logo is a registered trademark of Daniel Industnes tnc The Emerson logo is a trademark and service mark of Emerson Electric Co Brand mark listing are marks of one of the Emerson Process Management family of companies All other marks are property of their respecl ive owners The Daniel UltraSonic Gas Flow Meter including Mark III electronics is covered by US Patents 598330 and 4646 575 and patents pending The contents of this publication are presented for information purposes only and while effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or thel( use or applicability Daniel does not assume responsibility for the selection use or maintenance of any Daniel product Responsibility for proper selection use and maintenance of any Daniel product remains solely wilh the purchaser and end-userAII sales are governed by our terms and conditions which are available upon request We reserve the right to modify or improve the designs or specification of our products at any time without notice

-- -~J ~~--------- EMERSON bull ~ I

copy2004 Daniel Measurement and Control Inc All rights reserved Printed in the USA DAN -GFM-DS-0221-rev0404

reg DAN-3MT-3M-0801 -~I August 2001_-shy

3 SectioQltandProfiler Meter Tubes ~ Pf~6 5 ~~ IrMimiddot~

Instruments You Can Trust Daniel Meter Tubes are more than just fabricated pipe with an orifice fitting They are accurate dependable instruments because of Daniels dedicated approach to quality Extra steps taken during every phase of meter tube design and production separate Daniel Meter Tubes from all the rest

The Daniel 3 section meter tube is available with any style Senior or Junior orifice fitting Simplex plate holder or orifice flanges The assembly contains an inlet spool of the minimum length prescribed by the 143 standard The second section begins with a concentric flange mounted tube bund=1 leetln9 the 2000 API 143 requirements and a W thick spacer plate to ease tube removal for inspection The 04~r end of section 2 conshytains the orifice flange or fitting The third or downstream section follows and contains 2 branchOonnections and is extra long to allow for the addition of extra branch conshynections in the field If desired The standard meter tube has flanged outer ends Other end connections are avaUable on request

Inspectionffesting= Daniel maintains rigid inspection procedures during manufacturing of meter tubes Micrometer and internal surface roughness readings are recorded and supplied with each meter tUbe Customer or third party inspectors are welcome to verify these readings Radiography of welds is another service that is available

Fabrication Fabrication of your instrument Includes attaching the orifice fitting to the meter tube to make an integral primary measuring element For welding operashytions Daniel uses automatic welding machines and rotatshying positioners Highly skilled code qualified welders are employed to tum out highest quality on each job Special internal jigs and fixtures are used to insure smooth Inlet and outlet surfaces without steps or offsets All welds receive expert grinding by experienced craftsshy

men X

cl

-

gt shy

~

-

J ~

Features bull Dowel pin alignment close tolerance maleffemale

flange or knock out dowel pins insure that the bores of sections two and three are matched without offsets

One 1h and one 0 branch connection on the downstream for thermowell or other uses standard

Beveled flanged or reduced ends as well as any available weld fitting can be furnished on the ends of the tubes

Hydrostatically tested after manufacture

Each orifice fitting is tested for tap hole and orifice plate seal integrity after the meter tube has been pressure tested

Material Selection Daniel uses special cold drawn seamless tubing or honed pipe in the fabrication of meter tubes The strict reqUirements for intemal roundshyness and surface finish preclude the use of standard commercial pipe in most cases Daniel maintains a large inventory of this special pipe to rapidly complete your order

LT

EMERSON~ ltocess Management

~~------------------------------------------------------------~------------------------------

Raised Face Weld neck

NA

3M-30RW

3M-60RW High Pressure

3M-90RW 3M-150RW 3M-250RW

DAN-3MT-3M-0801 August 2001

3 Section Meter Tube Catalog Numbers 2-12 with Senior Fitting 10 amp 12 with Junior Fittina

~

Pressure Rating

150

Flange by Weld

(Flangnek)

3M-011

Flange by Flange

(Flanged)

3M-101

Weld by Weld

(Weldnek)

NA

Flange by Weld

(Flangnek)

3M-021

Flange by Flange

(Flanged)

3M-201

Weld by Weld

(Weldnek)

NA

300 3M-013 3M-103 NA 3M-023 3M-203 NA

600 3M-015 3M-105 3M-185 3M-025 3M-205 3M-285

H~h Pressure 3 Section Meter Tubes 900 3M-016 3M-106 3M-186 3M-026 3M-206 3M-286

1500 3M-017 3M-107 3M-187 3M-027 3M-207 3M-287

2500 3M-018 3M-108 3M-188 3M-028 3M-208 3M-288

2middot8 with Simplex 2middot12 with Orifice Flanges Flange byPressure

WeldRating Weld by Weld (Flangnek) (Weldnek)

150 3M-071 NA 3M-073300 NA

600 3M-075 3M-705 High Pressure

3M-7063M-076900 3M-7071500 3M-077 3M-7083M-0782500 -

Two Section Meter Tubes When Usmg Weldnek Flttmgs

Senior and Simplex fittings are also available in 10000 psi rating in some sizes All units are also available with Ring Type Joint (RTJ) flanges on request Sizes larger than 12 available on request

PackingShipping Daniel bolts together all meter A SPECIAL NOTE The use of factory original Daniel tubes when size permits before shipment This saves parts will assure your Senior Junior and Simplex Orifice the user time and field labor costs Fittings are protectshy fittings will stay within original specifications and operate ed by heavy lumber and the tube flanges by special-cut properly protectors

PaintingCoating The Daniel standard paint is a basic enamel type Special coatings such as multi-coat

offshore systems are available on request

3~Section Meter Tube with Tube Bundle

~-----~ U ----~---------~=~~middotmiddotmiddotmiddot~middot t)middotmiddot-middot ~- - -0bull )00)00 1

I~IC--middotmiddotmiddot-middot -----shyshy-bullmiddotV ------- ~

~ - ~-

~

ii~pound bullbullbull ~

Standard lenAths Size un Upstream 0 Downstream V (vane location)

3 7-5 4-0 130 4 9~~9 4-0 130

6 14-8 5-0 t30

102410 60middot middot 130 1~ +1 2tYS Tq 130 JiIf

Note Straightening vanes are not available in 2line size (See Dald Profller DAN-1852middot 2M)

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Daniel meter tubes can be supshyplied in many combinations and configurations Any of the orifice fittings plate holders or orifice flanges can be included in a meter tube Each 3 section standard meter tube is equipped with a flange mounted tube bundle straightener In accordance with April 2000 API 143 and a 1h thick spacer to facilitate tube removal for inspection Downstreams are longer than minimum required to allow for field Installation of additional branch connections If required

To specify a 3 section meter tube use the designation 3M followed by the type orifice holding deVice Ex 4 600 3 section meter tube with flanged ends using a Senior fitting flangneck style is specified as 4-3M-015 The same unit with a weldneck style Simplex is specified as 4middot3M-705 When ordering specify pipe schedule and end configuration Larger size and custom meter tube designs are available on request

The Daniel Profilertrade three section meter tube is availshy lows and contains 2 branch connections Other or addi able with any style Senior or Junior orifice fitting Simplex tiona I connections can be supplied in this section on plate holder or orifice flanges The assembly contains an request These meter tubes are for use in any piping conshyinlet spool of tile minimum length determined during testshy figuration with beta ratios to 67 Downstream sections ing to the API 143 standard The flange union between are extra long to allow for the addition of extra branch the first and second sections contains the ProfilerN and connections in the field if desired The standard meter a Y2 thick spacer plate to facilitate tube removal for tube has beveled outer ends Flanges or other end conshyinspection The outer end of section 2 contains the orishy nections are available on request fice flange or fitting The third or downstream section fol

Meter Tubes Catalog Numbers - 2 WI emor In9 bull Wit un or Itt ng2 1 th S Fitt 10 amp 12 h J i F i

Pressure Rating

Flange by Weld

(F1angnek)

Flange by Flange

(Flanged)

Weld by Weld

(Weldnek)

Flange by Weld

(Flangnek)

Flange by Flange

(Flanged)

Weld by Weld

(WeJdnek) 150 M011 M-101 NA M-021 M-201 NA 300 M-Q13 M-103 NA M023 M-203

NA 600 M-015 M-105 M-t85 M-025 M-205 M-285

2middot8 with Simplex 2middot12 with Orifice Flanges

Pressure Rating

Flange by Weld

weld by Weld

(Weldnek)CFlananekl 150 M-071 NA 300 M-073 NJA 6QfJ M-()75 M-705

Raised Face Weld Neck

NA - -

lM-30RW M-60RW

Two Section Meter Tube When USing Weldnek Fittings

Consult Factory for High Pressure Applications

PROFILERTM Flow Conditioning Plate

The Profiler has been tested and Shown to be in full compliance with the requirementS of API 143 April 2000 The Profiler both removes swirl

the tube bundle Available In flange mounted model only Also available In RTJ style on request

and creates a fully developed flow profile at the orifice Use of this unit allows shortened upstream straight pipe lengths of 17 diameters Beta ratio limit is 67 as with

-~---

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 14: Medidor de Flujo

--iI

-------~~--------1

----~----------------I _____________________I

----~------~----__i _____bullmiddot________ ----__i

____________shy____~__i

____________________---i __________________

_________shy__________~~

~ I ~

I

~

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

8

10

12

16

20

24

30

36 r

ANSI Class 300 600--~------------------------i

900__________----__------__------i 1500

-------------------------------~ Flange Raised Face (RF) _________________-_------j

Ring Type Joint (RTJ)___---------__bull-_____Imiddot

Materials Standard ~----~~--~----~--------~~ Stainless Steel

DJplex --~--------------------------~----~ _________________________--____~__

Device Type

Electronics

Transducers

Meter Size (Inches)

Daniel Ultrasonic Model Number Selections ES-21055 RevW

SeniorSonic (4-Path) ---------------1 JuniorSonic (1~Path) ------------1 JuniorSonic (2-Path) ______________

Mark II UL 24VDC 4-20rlA 3NPT

Mark UL 24VDC 1middot5VDC 3NPT ---------------------1 Mark CENaEC 24V DC 4-20mA M20 --------------_--__1

Mark IICB-JELEC24VDC1-SVDCM20

Mark II ClNELEc 24VDC 4-20mA M20 Rerrote

Mark II CENELEC 24VDC 1-5VDCM20 Rerrote

MarkU UL 24VOC4-20mA 3NPT Rerrote_

Mark II U~ 24VDC l-SVPG 3NPT Rerrote

Mark IIIUL 34 NPT

Mark III UL 34NPT Rerrote

TmiddotSlo T-12

4

middot 6

Page 6

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Systems Daniel Measurement and Control is the industry leader in designing constructing and commissioning of complex oil and gas metering systems to exacting standards

This global organization offers decades of petroleum fiscal flow measurement application experience Customers rely confidently on Daniels Systems Group international fabrication facilities customized engineering and its successes in field-testing and support From the simplest single-stream skid to complex on-site installations Daniel Systems delivers both natural gas and liquid petroleum tumkey applications Daniel Systems designs constructs and commissions the metering project blending up-toshythe-minute technology with decades of understanding what customers need and expect

Components of a Daniel Systems installation typically include meters valves provers flow-control instruments instrumentation and read-out equipment and process management components

Computer software and hardware are integrated with the measurement system Standard calculation methods include AGA3 (now API-MPMS-143) ISO 5167 AGA578 AGA9 and the API Manual for Petroleum Measurement Standards

Daniel DMSS-2000 Supervisory Control Systems utilize a sophisticated Graphical User Interface database server and a dedicated PLC for the metering skidMOV interface Redundancy is often used for custody transfer systems andor when system integrity is essential

A dedicated Project Manager and Project Team are assigned to each measurement system project This team is responsible for overall system design and project construction from start to finish A separate internal QAQC group reviews all design detailS inside and outside fabrication assembly and system testing

Whether it is a pipeline offshore production facility or a loading facility for ocean-going tankers the Daniel Systems group is a proven single-source solution for customers throughout the world

Page 7

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Daniel Measurement Services Daniel Measurement Services takes pride in being there after needs arise with the right solution for customers with gas and liquid fiscal flow measurement applications

Around the clock and around the world Daniel Measurement Services has experienced highly qualified people prepared to help customers who need assistance with the following

middot Start-up and commissioning middot Preventive maintenance middot Product repair I upgrades middot Project management and integration middot Meter Tube inspection and recertification middot Remote diagnostics middot Warranty Plus middot Technical training

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880

Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337

Stirling Scotland - UK Middle East amp Africa T +4401786433400 F +44 01786433401

Singapore - Asia Pacific T +65-6777-8211 F +65-6770-8001

USA Toll Free 1-888-FLOW-001 wwwdanielcom

Daniel is a whOlly owned subsidiary of Emerson Electric Co and a division of Emerson Process Management The Daniel logo is a registered trademark of Daniel Industnes tnc The Emerson logo is a trademark and service mark of Emerson Electric Co Brand mark listing are marks of one of the Emerson Process Management family of companies All other marks are property of their respecl ive owners The Daniel UltraSonic Gas Flow Meter including Mark III electronics is covered by US Patents 598330 and 4646 575 and patents pending The contents of this publication are presented for information purposes only and while effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or thel( use or applicability Daniel does not assume responsibility for the selection use or maintenance of any Daniel product Responsibility for proper selection use and maintenance of any Daniel product remains solely wilh the purchaser and end-userAII sales are governed by our terms and conditions which are available upon request We reserve the right to modify or improve the designs or specification of our products at any time without notice

-- -~J ~~--------- EMERSON bull ~ I

copy2004 Daniel Measurement and Control Inc All rights reserved Printed in the USA DAN -GFM-DS-0221-rev0404

reg DAN-3MT-3M-0801 -~I August 2001_-shy

3 SectioQltandProfiler Meter Tubes ~ Pf~6 5 ~~ IrMimiddot~

Instruments You Can Trust Daniel Meter Tubes are more than just fabricated pipe with an orifice fitting They are accurate dependable instruments because of Daniels dedicated approach to quality Extra steps taken during every phase of meter tube design and production separate Daniel Meter Tubes from all the rest

The Daniel 3 section meter tube is available with any style Senior or Junior orifice fitting Simplex plate holder or orifice flanges The assembly contains an inlet spool of the minimum length prescribed by the 143 standard The second section begins with a concentric flange mounted tube bund=1 leetln9 the 2000 API 143 requirements and a W thick spacer plate to ease tube removal for inspection The 04~r end of section 2 conshytains the orifice flange or fitting The third or downstream section follows and contains 2 branchOonnections and is extra long to allow for the addition of extra branch conshynections in the field If desired The standard meter tube has flanged outer ends Other end connections are avaUable on request

Inspectionffesting= Daniel maintains rigid inspection procedures during manufacturing of meter tubes Micrometer and internal surface roughness readings are recorded and supplied with each meter tUbe Customer or third party inspectors are welcome to verify these readings Radiography of welds is another service that is available

Fabrication Fabrication of your instrument Includes attaching the orifice fitting to the meter tube to make an integral primary measuring element For welding operashytions Daniel uses automatic welding machines and rotatshying positioners Highly skilled code qualified welders are employed to tum out highest quality on each job Special internal jigs and fixtures are used to insure smooth Inlet and outlet surfaces without steps or offsets All welds receive expert grinding by experienced craftsshy

men X

cl

-

gt shy

~

-

J ~

Features bull Dowel pin alignment close tolerance maleffemale

flange or knock out dowel pins insure that the bores of sections two and three are matched without offsets

One 1h and one 0 branch connection on the downstream for thermowell or other uses standard

Beveled flanged or reduced ends as well as any available weld fitting can be furnished on the ends of the tubes

Hydrostatically tested after manufacture

Each orifice fitting is tested for tap hole and orifice plate seal integrity after the meter tube has been pressure tested

Material Selection Daniel uses special cold drawn seamless tubing or honed pipe in the fabrication of meter tubes The strict reqUirements for intemal roundshyness and surface finish preclude the use of standard commercial pipe in most cases Daniel maintains a large inventory of this special pipe to rapidly complete your order

LT

EMERSON~ ltocess Management

~~------------------------------------------------------------~------------------------------

Raised Face Weld neck

NA

3M-30RW

3M-60RW High Pressure

3M-90RW 3M-150RW 3M-250RW

DAN-3MT-3M-0801 August 2001

3 Section Meter Tube Catalog Numbers 2-12 with Senior Fitting 10 amp 12 with Junior Fittina

~

Pressure Rating

150

Flange by Weld

(Flangnek)

3M-011

Flange by Flange

(Flanged)

3M-101

Weld by Weld

(Weldnek)

NA

Flange by Weld

(Flangnek)

3M-021

Flange by Flange

(Flanged)

3M-201

Weld by Weld

(Weldnek)

NA

300 3M-013 3M-103 NA 3M-023 3M-203 NA

600 3M-015 3M-105 3M-185 3M-025 3M-205 3M-285

H~h Pressure 3 Section Meter Tubes 900 3M-016 3M-106 3M-186 3M-026 3M-206 3M-286

1500 3M-017 3M-107 3M-187 3M-027 3M-207 3M-287

2500 3M-018 3M-108 3M-188 3M-028 3M-208 3M-288

2middot8 with Simplex 2middot12 with Orifice Flanges Flange byPressure

WeldRating Weld by Weld (Flangnek) (Weldnek)

150 3M-071 NA 3M-073300 NA

600 3M-075 3M-705 High Pressure

3M-7063M-076900 3M-7071500 3M-077 3M-7083M-0782500 -

Two Section Meter Tubes When Usmg Weldnek Flttmgs

Senior and Simplex fittings are also available in 10000 psi rating in some sizes All units are also available with Ring Type Joint (RTJ) flanges on request Sizes larger than 12 available on request

PackingShipping Daniel bolts together all meter A SPECIAL NOTE The use of factory original Daniel tubes when size permits before shipment This saves parts will assure your Senior Junior and Simplex Orifice the user time and field labor costs Fittings are protectshy fittings will stay within original specifications and operate ed by heavy lumber and the tube flanges by special-cut properly protectors

PaintingCoating The Daniel standard paint is a basic enamel type Special coatings such as multi-coat

offshore systems are available on request

3~Section Meter Tube with Tube Bundle

~-----~ U ----~---------~=~~middotmiddotmiddotmiddot~middot t)middotmiddot-middot ~- - -0bull )00)00 1

I~IC--middotmiddotmiddot-middot -----shyshy-bullmiddotV ------- ~

~ - ~-

~

ii~pound bullbullbull ~

Standard lenAths Size un Upstream 0 Downstream V (vane location)

3 7-5 4-0 130 4 9~~9 4-0 130

6 14-8 5-0 t30

102410 60middot middot 130 1~ +1 2tYS Tq 130 JiIf

Note Straightening vanes are not available in 2line size (See Dald Profller DAN-1852middot 2M)

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Daniel meter tubes can be supshyplied in many combinations and configurations Any of the orifice fittings plate holders or orifice flanges can be included in a meter tube Each 3 section standard meter tube is equipped with a flange mounted tube bundle straightener In accordance with April 2000 API 143 and a 1h thick spacer to facilitate tube removal for inspection Downstreams are longer than minimum required to allow for field Installation of additional branch connections If required

To specify a 3 section meter tube use the designation 3M followed by the type orifice holding deVice Ex 4 600 3 section meter tube with flanged ends using a Senior fitting flangneck style is specified as 4-3M-015 The same unit with a weldneck style Simplex is specified as 4middot3M-705 When ordering specify pipe schedule and end configuration Larger size and custom meter tube designs are available on request

The Daniel Profilertrade three section meter tube is availshy lows and contains 2 branch connections Other or addi able with any style Senior or Junior orifice fitting Simplex tiona I connections can be supplied in this section on plate holder or orifice flanges The assembly contains an request These meter tubes are for use in any piping conshyinlet spool of tile minimum length determined during testshy figuration with beta ratios to 67 Downstream sections ing to the API 143 standard The flange union between are extra long to allow for the addition of extra branch the first and second sections contains the ProfilerN and connections in the field if desired The standard meter a Y2 thick spacer plate to facilitate tube removal for tube has beveled outer ends Flanges or other end conshyinspection The outer end of section 2 contains the orishy nections are available on request fice flange or fitting The third or downstream section fol

Meter Tubes Catalog Numbers - 2 WI emor In9 bull Wit un or Itt ng2 1 th S Fitt 10 amp 12 h J i F i

Pressure Rating

Flange by Weld

(F1angnek)

Flange by Flange

(Flanged)

Weld by Weld

(Weldnek)

Flange by Weld

(Flangnek)

Flange by Flange

(Flanged)

Weld by Weld

(WeJdnek) 150 M011 M-101 NA M-021 M-201 NA 300 M-Q13 M-103 NA M023 M-203

NA 600 M-015 M-105 M-t85 M-025 M-205 M-285

2middot8 with Simplex 2middot12 with Orifice Flanges

Pressure Rating

Flange by Weld

weld by Weld

(Weldnek)CFlananekl 150 M-071 NA 300 M-073 NJA 6QfJ M-()75 M-705

Raised Face Weld Neck

NA - -

lM-30RW M-60RW

Two Section Meter Tube When USing Weldnek Fittings

Consult Factory for High Pressure Applications

PROFILERTM Flow Conditioning Plate

The Profiler has been tested and Shown to be in full compliance with the requirementS of API 143 April 2000 The Profiler both removes swirl

the tube bundle Available In flange mounted model only Also available In RTJ style on request

and creates a fully developed flow profile at the orifice Use of this unit allows shortened upstream straight pipe lengths of 17 diameters Beta ratio limit is 67 as with

-~---

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 15: Medidor de Flujo

Product Data Sheet DAN-GFM-DS-21-rev0404 April 2004

Systems Daniel Measurement and Control is the industry leader in designing constructing and commissioning of complex oil and gas metering systems to exacting standards

This global organization offers decades of petroleum fiscal flow measurement application experience Customers rely confidently on Daniels Systems Group international fabrication facilities customized engineering and its successes in field-testing and support From the simplest single-stream skid to complex on-site installations Daniel Systems delivers both natural gas and liquid petroleum tumkey applications Daniel Systems designs constructs and commissions the metering project blending up-toshythe-minute technology with decades of understanding what customers need and expect

Components of a Daniel Systems installation typically include meters valves provers flow-control instruments instrumentation and read-out equipment and process management components

Computer software and hardware are integrated with the measurement system Standard calculation methods include AGA3 (now API-MPMS-143) ISO 5167 AGA578 AGA9 and the API Manual for Petroleum Measurement Standards

Daniel DMSS-2000 Supervisory Control Systems utilize a sophisticated Graphical User Interface database server and a dedicated PLC for the metering skidMOV interface Redundancy is often used for custody transfer systems andor when system integrity is essential

A dedicated Project Manager and Project Team are assigned to each measurement system project This team is responsible for overall system design and project construction from start to finish A separate internal QAQC group reviews all design detailS inside and outside fabrication assembly and system testing

Whether it is a pipeline offshore production facility or a loading facility for ocean-going tankers the Daniel Systems group is a proven single-source solution for customers throughout the world

Page 7

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Daniel Measurement Services Daniel Measurement Services takes pride in being there after needs arise with the right solution for customers with gas and liquid fiscal flow measurement applications

Around the clock and around the world Daniel Measurement Services has experienced highly qualified people prepared to help customers who need assistance with the following

middot Start-up and commissioning middot Preventive maintenance middot Product repair I upgrades middot Project management and integration middot Meter Tube inspection and recertification middot Remote diagnostics middot Warranty Plus middot Technical training

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880

Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337

Stirling Scotland - UK Middle East amp Africa T +4401786433400 F +44 01786433401

Singapore - Asia Pacific T +65-6777-8211 F +65-6770-8001

USA Toll Free 1-888-FLOW-001 wwwdanielcom

Daniel is a whOlly owned subsidiary of Emerson Electric Co and a division of Emerson Process Management The Daniel logo is a registered trademark of Daniel Industnes tnc The Emerson logo is a trademark and service mark of Emerson Electric Co Brand mark listing are marks of one of the Emerson Process Management family of companies All other marks are property of their respecl ive owners The Daniel UltraSonic Gas Flow Meter including Mark III electronics is covered by US Patents 598330 and 4646 575 and patents pending The contents of this publication are presented for information purposes only and while effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or thel( use or applicability Daniel does not assume responsibility for the selection use or maintenance of any Daniel product Responsibility for proper selection use and maintenance of any Daniel product remains solely wilh the purchaser and end-userAII sales are governed by our terms and conditions which are available upon request We reserve the right to modify or improve the designs or specification of our products at any time without notice

-- -~J ~~--------- EMERSON bull ~ I

copy2004 Daniel Measurement and Control Inc All rights reserved Printed in the USA DAN -GFM-DS-0221-rev0404

reg DAN-3MT-3M-0801 -~I August 2001_-shy

3 SectioQltandProfiler Meter Tubes ~ Pf~6 5 ~~ IrMimiddot~

Instruments You Can Trust Daniel Meter Tubes are more than just fabricated pipe with an orifice fitting They are accurate dependable instruments because of Daniels dedicated approach to quality Extra steps taken during every phase of meter tube design and production separate Daniel Meter Tubes from all the rest

The Daniel 3 section meter tube is available with any style Senior or Junior orifice fitting Simplex plate holder or orifice flanges The assembly contains an inlet spool of the minimum length prescribed by the 143 standard The second section begins with a concentric flange mounted tube bund=1 leetln9 the 2000 API 143 requirements and a W thick spacer plate to ease tube removal for inspection The 04~r end of section 2 conshytains the orifice flange or fitting The third or downstream section follows and contains 2 branchOonnections and is extra long to allow for the addition of extra branch conshynections in the field If desired The standard meter tube has flanged outer ends Other end connections are avaUable on request

Inspectionffesting= Daniel maintains rigid inspection procedures during manufacturing of meter tubes Micrometer and internal surface roughness readings are recorded and supplied with each meter tUbe Customer or third party inspectors are welcome to verify these readings Radiography of welds is another service that is available

Fabrication Fabrication of your instrument Includes attaching the orifice fitting to the meter tube to make an integral primary measuring element For welding operashytions Daniel uses automatic welding machines and rotatshying positioners Highly skilled code qualified welders are employed to tum out highest quality on each job Special internal jigs and fixtures are used to insure smooth Inlet and outlet surfaces without steps or offsets All welds receive expert grinding by experienced craftsshy

men X

cl

-

gt shy

~

-

J ~

Features bull Dowel pin alignment close tolerance maleffemale

flange or knock out dowel pins insure that the bores of sections two and three are matched without offsets

One 1h and one 0 branch connection on the downstream for thermowell or other uses standard

Beveled flanged or reduced ends as well as any available weld fitting can be furnished on the ends of the tubes

Hydrostatically tested after manufacture

Each orifice fitting is tested for tap hole and orifice plate seal integrity after the meter tube has been pressure tested

Material Selection Daniel uses special cold drawn seamless tubing or honed pipe in the fabrication of meter tubes The strict reqUirements for intemal roundshyness and surface finish preclude the use of standard commercial pipe in most cases Daniel maintains a large inventory of this special pipe to rapidly complete your order

LT

EMERSON~ ltocess Management

~~------------------------------------------------------------~------------------------------

Raised Face Weld neck

NA

3M-30RW

3M-60RW High Pressure

3M-90RW 3M-150RW 3M-250RW

DAN-3MT-3M-0801 August 2001

3 Section Meter Tube Catalog Numbers 2-12 with Senior Fitting 10 amp 12 with Junior Fittina

~

Pressure Rating

150

Flange by Weld

(Flangnek)

3M-011

Flange by Flange

(Flanged)

3M-101

Weld by Weld

(Weldnek)

NA

Flange by Weld

(Flangnek)

3M-021

Flange by Flange

(Flanged)

3M-201

Weld by Weld

(Weldnek)

NA

300 3M-013 3M-103 NA 3M-023 3M-203 NA

600 3M-015 3M-105 3M-185 3M-025 3M-205 3M-285

H~h Pressure 3 Section Meter Tubes 900 3M-016 3M-106 3M-186 3M-026 3M-206 3M-286

1500 3M-017 3M-107 3M-187 3M-027 3M-207 3M-287

2500 3M-018 3M-108 3M-188 3M-028 3M-208 3M-288

2middot8 with Simplex 2middot12 with Orifice Flanges Flange byPressure

WeldRating Weld by Weld (Flangnek) (Weldnek)

150 3M-071 NA 3M-073300 NA

600 3M-075 3M-705 High Pressure

3M-7063M-076900 3M-7071500 3M-077 3M-7083M-0782500 -

Two Section Meter Tubes When Usmg Weldnek Flttmgs

Senior and Simplex fittings are also available in 10000 psi rating in some sizes All units are also available with Ring Type Joint (RTJ) flanges on request Sizes larger than 12 available on request

PackingShipping Daniel bolts together all meter A SPECIAL NOTE The use of factory original Daniel tubes when size permits before shipment This saves parts will assure your Senior Junior and Simplex Orifice the user time and field labor costs Fittings are protectshy fittings will stay within original specifications and operate ed by heavy lumber and the tube flanges by special-cut properly protectors

PaintingCoating The Daniel standard paint is a basic enamel type Special coatings such as multi-coat

offshore systems are available on request

3~Section Meter Tube with Tube Bundle

~-----~ U ----~---------~=~~middotmiddotmiddotmiddot~middot t)middotmiddot-middot ~- - -0bull )00)00 1

I~IC--middotmiddotmiddot-middot -----shyshy-bullmiddotV ------- ~

~ - ~-

~

ii~pound bullbullbull ~

Standard lenAths Size un Upstream 0 Downstream V (vane location)

3 7-5 4-0 130 4 9~~9 4-0 130

6 14-8 5-0 t30

102410 60middot middot 130 1~ +1 2tYS Tq 130 JiIf

Note Straightening vanes are not available in 2line size (See Dald Profller DAN-1852middot 2M)

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Daniel meter tubes can be supshyplied in many combinations and configurations Any of the orifice fittings plate holders or orifice flanges can be included in a meter tube Each 3 section standard meter tube is equipped with a flange mounted tube bundle straightener In accordance with April 2000 API 143 and a 1h thick spacer to facilitate tube removal for inspection Downstreams are longer than minimum required to allow for field Installation of additional branch connections If required

To specify a 3 section meter tube use the designation 3M followed by the type orifice holding deVice Ex 4 600 3 section meter tube with flanged ends using a Senior fitting flangneck style is specified as 4-3M-015 The same unit with a weldneck style Simplex is specified as 4middot3M-705 When ordering specify pipe schedule and end configuration Larger size and custom meter tube designs are available on request

The Daniel Profilertrade three section meter tube is availshy lows and contains 2 branch connections Other or addi able with any style Senior or Junior orifice fitting Simplex tiona I connections can be supplied in this section on plate holder or orifice flanges The assembly contains an request These meter tubes are for use in any piping conshyinlet spool of tile minimum length determined during testshy figuration with beta ratios to 67 Downstream sections ing to the API 143 standard The flange union between are extra long to allow for the addition of extra branch the first and second sections contains the ProfilerN and connections in the field if desired The standard meter a Y2 thick spacer plate to facilitate tube removal for tube has beveled outer ends Flanges or other end conshyinspection The outer end of section 2 contains the orishy nections are available on request fice flange or fitting The third or downstream section fol

Meter Tubes Catalog Numbers - 2 WI emor In9 bull Wit un or Itt ng2 1 th S Fitt 10 amp 12 h J i F i

Pressure Rating

Flange by Weld

(F1angnek)

Flange by Flange

(Flanged)

Weld by Weld

(Weldnek)

Flange by Weld

(Flangnek)

Flange by Flange

(Flanged)

Weld by Weld

(WeJdnek) 150 M011 M-101 NA M-021 M-201 NA 300 M-Q13 M-103 NA M023 M-203

NA 600 M-015 M-105 M-t85 M-025 M-205 M-285

2middot8 with Simplex 2middot12 with Orifice Flanges

Pressure Rating

Flange by Weld

weld by Weld

(Weldnek)CFlananekl 150 M-071 NA 300 M-073 NJA 6QfJ M-()75 M-705

Raised Face Weld Neck

NA - -

lM-30RW M-60RW

Two Section Meter Tube When USing Weldnek Fittings

Consult Factory for High Pressure Applications

PROFILERTM Flow Conditioning Plate

The Profiler has been tested and Shown to be in full compliance with the requirementS of API 143 April 2000 The Profiler both removes swirl

the tube bundle Available In flange mounted model only Also available In RTJ style on request

and creates a fully developed flow profile at the orifice Use of this unit allows shortened upstream straight pipe lengths of 17 diameters Beta ratio limit is 67 as with

-~---

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 16: Medidor de Flujo

Product Data Sheet DAN-GFM-DS-21-rev0404 April2004

Daniel Measurement Services Daniel Measurement Services takes pride in being there after needs arise with the right solution for customers with gas and liquid fiscal flow measurement applications

Around the clock and around the world Daniel Measurement Services has experienced highly qualified people prepared to help customers who need assistance with the following

middot Start-up and commissioning middot Preventive maintenance middot Product repair I upgrades middot Project management and integration middot Meter Tube inspection and recertification middot Remote diagnostics middot Warranty Plus middot Technical training

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880

Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337

Stirling Scotland - UK Middle East amp Africa T +4401786433400 F +44 01786433401

Singapore - Asia Pacific T +65-6777-8211 F +65-6770-8001

USA Toll Free 1-888-FLOW-001 wwwdanielcom

Daniel is a whOlly owned subsidiary of Emerson Electric Co and a division of Emerson Process Management The Daniel logo is a registered trademark of Daniel Industnes tnc The Emerson logo is a trademark and service mark of Emerson Electric Co Brand mark listing are marks of one of the Emerson Process Management family of companies All other marks are property of their respecl ive owners The Daniel UltraSonic Gas Flow Meter including Mark III electronics is covered by US Patents 598330 and 4646 575 and patents pending The contents of this publication are presented for information purposes only and while effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or thel( use or applicability Daniel does not assume responsibility for the selection use or maintenance of any Daniel product Responsibility for proper selection use and maintenance of any Daniel product remains solely wilh the purchaser and end-userAII sales are governed by our terms and conditions which are available upon request We reserve the right to modify or improve the designs or specification of our products at any time without notice

-- -~J ~~--------- EMERSON bull ~ I

copy2004 Daniel Measurement and Control Inc All rights reserved Printed in the USA DAN -GFM-DS-0221-rev0404

reg DAN-3MT-3M-0801 -~I August 2001_-shy

3 SectioQltandProfiler Meter Tubes ~ Pf~6 5 ~~ IrMimiddot~

Instruments You Can Trust Daniel Meter Tubes are more than just fabricated pipe with an orifice fitting They are accurate dependable instruments because of Daniels dedicated approach to quality Extra steps taken during every phase of meter tube design and production separate Daniel Meter Tubes from all the rest

The Daniel 3 section meter tube is available with any style Senior or Junior orifice fitting Simplex plate holder or orifice flanges The assembly contains an inlet spool of the minimum length prescribed by the 143 standard The second section begins with a concentric flange mounted tube bund=1 leetln9 the 2000 API 143 requirements and a W thick spacer plate to ease tube removal for inspection The 04~r end of section 2 conshytains the orifice flange or fitting The third or downstream section follows and contains 2 branchOonnections and is extra long to allow for the addition of extra branch conshynections in the field If desired The standard meter tube has flanged outer ends Other end connections are avaUable on request

Inspectionffesting= Daniel maintains rigid inspection procedures during manufacturing of meter tubes Micrometer and internal surface roughness readings are recorded and supplied with each meter tUbe Customer or third party inspectors are welcome to verify these readings Radiography of welds is another service that is available

Fabrication Fabrication of your instrument Includes attaching the orifice fitting to the meter tube to make an integral primary measuring element For welding operashytions Daniel uses automatic welding machines and rotatshying positioners Highly skilled code qualified welders are employed to tum out highest quality on each job Special internal jigs and fixtures are used to insure smooth Inlet and outlet surfaces without steps or offsets All welds receive expert grinding by experienced craftsshy

men X

cl

-

gt shy

~

-

J ~

Features bull Dowel pin alignment close tolerance maleffemale

flange or knock out dowel pins insure that the bores of sections two and three are matched without offsets

One 1h and one 0 branch connection on the downstream for thermowell or other uses standard

Beveled flanged or reduced ends as well as any available weld fitting can be furnished on the ends of the tubes

Hydrostatically tested after manufacture

Each orifice fitting is tested for tap hole and orifice plate seal integrity after the meter tube has been pressure tested

Material Selection Daniel uses special cold drawn seamless tubing or honed pipe in the fabrication of meter tubes The strict reqUirements for intemal roundshyness and surface finish preclude the use of standard commercial pipe in most cases Daniel maintains a large inventory of this special pipe to rapidly complete your order

LT

EMERSON~ ltocess Management

~~------------------------------------------------------------~------------------------------

Raised Face Weld neck

NA

3M-30RW

3M-60RW High Pressure

3M-90RW 3M-150RW 3M-250RW

DAN-3MT-3M-0801 August 2001

3 Section Meter Tube Catalog Numbers 2-12 with Senior Fitting 10 amp 12 with Junior Fittina

~

Pressure Rating

150

Flange by Weld

(Flangnek)

3M-011

Flange by Flange

(Flanged)

3M-101

Weld by Weld

(Weldnek)

NA

Flange by Weld

(Flangnek)

3M-021

Flange by Flange

(Flanged)

3M-201

Weld by Weld

(Weldnek)

NA

300 3M-013 3M-103 NA 3M-023 3M-203 NA

600 3M-015 3M-105 3M-185 3M-025 3M-205 3M-285

H~h Pressure 3 Section Meter Tubes 900 3M-016 3M-106 3M-186 3M-026 3M-206 3M-286

1500 3M-017 3M-107 3M-187 3M-027 3M-207 3M-287

2500 3M-018 3M-108 3M-188 3M-028 3M-208 3M-288

2middot8 with Simplex 2middot12 with Orifice Flanges Flange byPressure

WeldRating Weld by Weld (Flangnek) (Weldnek)

150 3M-071 NA 3M-073300 NA

600 3M-075 3M-705 High Pressure

3M-7063M-076900 3M-7071500 3M-077 3M-7083M-0782500 -

Two Section Meter Tubes When Usmg Weldnek Flttmgs

Senior and Simplex fittings are also available in 10000 psi rating in some sizes All units are also available with Ring Type Joint (RTJ) flanges on request Sizes larger than 12 available on request

PackingShipping Daniel bolts together all meter A SPECIAL NOTE The use of factory original Daniel tubes when size permits before shipment This saves parts will assure your Senior Junior and Simplex Orifice the user time and field labor costs Fittings are protectshy fittings will stay within original specifications and operate ed by heavy lumber and the tube flanges by special-cut properly protectors

PaintingCoating The Daniel standard paint is a basic enamel type Special coatings such as multi-coat

offshore systems are available on request

3~Section Meter Tube with Tube Bundle

~-----~ U ----~---------~=~~middotmiddotmiddotmiddot~middot t)middotmiddot-middot ~- - -0bull )00)00 1

I~IC--middotmiddotmiddot-middot -----shyshy-bullmiddotV ------- ~

~ - ~-

~

ii~pound bullbullbull ~

Standard lenAths Size un Upstream 0 Downstream V (vane location)

3 7-5 4-0 130 4 9~~9 4-0 130

6 14-8 5-0 t30

102410 60middot middot 130 1~ +1 2tYS Tq 130 JiIf

Note Straightening vanes are not available in 2line size (See Dald Profller DAN-1852middot 2M)

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Daniel meter tubes can be supshyplied in many combinations and configurations Any of the orifice fittings plate holders or orifice flanges can be included in a meter tube Each 3 section standard meter tube is equipped with a flange mounted tube bundle straightener In accordance with April 2000 API 143 and a 1h thick spacer to facilitate tube removal for inspection Downstreams are longer than minimum required to allow for field Installation of additional branch connections If required

To specify a 3 section meter tube use the designation 3M followed by the type orifice holding deVice Ex 4 600 3 section meter tube with flanged ends using a Senior fitting flangneck style is specified as 4-3M-015 The same unit with a weldneck style Simplex is specified as 4middot3M-705 When ordering specify pipe schedule and end configuration Larger size and custom meter tube designs are available on request

The Daniel Profilertrade three section meter tube is availshy lows and contains 2 branch connections Other or addi able with any style Senior or Junior orifice fitting Simplex tiona I connections can be supplied in this section on plate holder or orifice flanges The assembly contains an request These meter tubes are for use in any piping conshyinlet spool of tile minimum length determined during testshy figuration with beta ratios to 67 Downstream sections ing to the API 143 standard The flange union between are extra long to allow for the addition of extra branch the first and second sections contains the ProfilerN and connections in the field if desired The standard meter a Y2 thick spacer plate to facilitate tube removal for tube has beveled outer ends Flanges or other end conshyinspection The outer end of section 2 contains the orishy nections are available on request fice flange or fitting The third or downstream section fol

Meter Tubes Catalog Numbers - 2 WI emor In9 bull Wit un or Itt ng2 1 th S Fitt 10 amp 12 h J i F i

Pressure Rating

Flange by Weld

(F1angnek)

Flange by Flange

(Flanged)

Weld by Weld

(Weldnek)

Flange by Weld

(Flangnek)

Flange by Flange

(Flanged)

Weld by Weld

(WeJdnek) 150 M011 M-101 NA M-021 M-201 NA 300 M-Q13 M-103 NA M023 M-203

NA 600 M-015 M-105 M-t85 M-025 M-205 M-285

2middot8 with Simplex 2middot12 with Orifice Flanges

Pressure Rating

Flange by Weld

weld by Weld

(Weldnek)CFlananekl 150 M-071 NA 300 M-073 NJA 6QfJ M-()75 M-705

Raised Face Weld Neck

NA - -

lM-30RW M-60RW

Two Section Meter Tube When USing Weldnek Fittings

Consult Factory for High Pressure Applications

PROFILERTM Flow Conditioning Plate

The Profiler has been tested and Shown to be in full compliance with the requirementS of API 143 April 2000 The Profiler both removes swirl

the tube bundle Available In flange mounted model only Also available In RTJ style on request

and creates a fully developed flow profile at the orifice Use of this unit allows shortened upstream straight pipe lengths of 17 diameters Beta ratio limit is 67 as with

-~---

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 17: Medidor de Flujo

reg DAN-3MT-3M-0801 -~I August 2001_-shy

3 SectioQltandProfiler Meter Tubes ~ Pf~6 5 ~~ IrMimiddot~

Instruments You Can Trust Daniel Meter Tubes are more than just fabricated pipe with an orifice fitting They are accurate dependable instruments because of Daniels dedicated approach to quality Extra steps taken during every phase of meter tube design and production separate Daniel Meter Tubes from all the rest

The Daniel 3 section meter tube is available with any style Senior or Junior orifice fitting Simplex plate holder or orifice flanges The assembly contains an inlet spool of the minimum length prescribed by the 143 standard The second section begins with a concentric flange mounted tube bund=1 leetln9 the 2000 API 143 requirements and a W thick spacer plate to ease tube removal for inspection The 04~r end of section 2 conshytains the orifice flange or fitting The third or downstream section follows and contains 2 branchOonnections and is extra long to allow for the addition of extra branch conshynections in the field If desired The standard meter tube has flanged outer ends Other end connections are avaUable on request

Inspectionffesting= Daniel maintains rigid inspection procedures during manufacturing of meter tubes Micrometer and internal surface roughness readings are recorded and supplied with each meter tUbe Customer or third party inspectors are welcome to verify these readings Radiography of welds is another service that is available

Fabrication Fabrication of your instrument Includes attaching the orifice fitting to the meter tube to make an integral primary measuring element For welding operashytions Daniel uses automatic welding machines and rotatshying positioners Highly skilled code qualified welders are employed to tum out highest quality on each job Special internal jigs and fixtures are used to insure smooth Inlet and outlet surfaces without steps or offsets All welds receive expert grinding by experienced craftsshy

men X

cl

-

gt shy

~

-

J ~

Features bull Dowel pin alignment close tolerance maleffemale

flange or knock out dowel pins insure that the bores of sections two and three are matched without offsets

One 1h and one 0 branch connection on the downstream for thermowell or other uses standard

Beveled flanged or reduced ends as well as any available weld fitting can be furnished on the ends of the tubes

Hydrostatically tested after manufacture

Each orifice fitting is tested for tap hole and orifice plate seal integrity after the meter tube has been pressure tested

Material Selection Daniel uses special cold drawn seamless tubing or honed pipe in the fabrication of meter tubes The strict reqUirements for intemal roundshyness and surface finish preclude the use of standard commercial pipe in most cases Daniel maintains a large inventory of this special pipe to rapidly complete your order

LT

EMERSON~ ltocess Management

~~------------------------------------------------------------~------------------------------

Raised Face Weld neck

NA

3M-30RW

3M-60RW High Pressure

3M-90RW 3M-150RW 3M-250RW

DAN-3MT-3M-0801 August 2001

3 Section Meter Tube Catalog Numbers 2-12 with Senior Fitting 10 amp 12 with Junior Fittina

~

Pressure Rating

150

Flange by Weld

(Flangnek)

3M-011

Flange by Flange

(Flanged)

3M-101

Weld by Weld

(Weldnek)

NA

Flange by Weld

(Flangnek)

3M-021

Flange by Flange

(Flanged)

3M-201

Weld by Weld

(Weldnek)

NA

300 3M-013 3M-103 NA 3M-023 3M-203 NA

600 3M-015 3M-105 3M-185 3M-025 3M-205 3M-285

H~h Pressure 3 Section Meter Tubes 900 3M-016 3M-106 3M-186 3M-026 3M-206 3M-286

1500 3M-017 3M-107 3M-187 3M-027 3M-207 3M-287

2500 3M-018 3M-108 3M-188 3M-028 3M-208 3M-288

2middot8 with Simplex 2middot12 with Orifice Flanges Flange byPressure

WeldRating Weld by Weld (Flangnek) (Weldnek)

150 3M-071 NA 3M-073300 NA

600 3M-075 3M-705 High Pressure

3M-7063M-076900 3M-7071500 3M-077 3M-7083M-0782500 -

Two Section Meter Tubes When Usmg Weldnek Flttmgs

Senior and Simplex fittings are also available in 10000 psi rating in some sizes All units are also available with Ring Type Joint (RTJ) flanges on request Sizes larger than 12 available on request

PackingShipping Daniel bolts together all meter A SPECIAL NOTE The use of factory original Daniel tubes when size permits before shipment This saves parts will assure your Senior Junior and Simplex Orifice the user time and field labor costs Fittings are protectshy fittings will stay within original specifications and operate ed by heavy lumber and the tube flanges by special-cut properly protectors

PaintingCoating The Daniel standard paint is a basic enamel type Special coatings such as multi-coat

offshore systems are available on request

3~Section Meter Tube with Tube Bundle

~-----~ U ----~---------~=~~middotmiddotmiddotmiddot~middot t)middotmiddot-middot ~- - -0bull )00)00 1

I~IC--middotmiddotmiddot-middot -----shyshy-bullmiddotV ------- ~

~ - ~-

~

ii~pound bullbullbull ~

Standard lenAths Size un Upstream 0 Downstream V (vane location)

3 7-5 4-0 130 4 9~~9 4-0 130

6 14-8 5-0 t30

102410 60middot middot 130 1~ +1 2tYS Tq 130 JiIf

Note Straightening vanes are not available in 2line size (See Dald Profller DAN-1852middot 2M)

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Daniel meter tubes can be supshyplied in many combinations and configurations Any of the orifice fittings plate holders or orifice flanges can be included in a meter tube Each 3 section standard meter tube is equipped with a flange mounted tube bundle straightener In accordance with April 2000 API 143 and a 1h thick spacer to facilitate tube removal for inspection Downstreams are longer than minimum required to allow for field Installation of additional branch connections If required

To specify a 3 section meter tube use the designation 3M followed by the type orifice holding deVice Ex 4 600 3 section meter tube with flanged ends using a Senior fitting flangneck style is specified as 4-3M-015 The same unit with a weldneck style Simplex is specified as 4middot3M-705 When ordering specify pipe schedule and end configuration Larger size and custom meter tube designs are available on request

The Daniel Profilertrade three section meter tube is availshy lows and contains 2 branch connections Other or addi able with any style Senior or Junior orifice fitting Simplex tiona I connections can be supplied in this section on plate holder or orifice flanges The assembly contains an request These meter tubes are for use in any piping conshyinlet spool of tile minimum length determined during testshy figuration with beta ratios to 67 Downstream sections ing to the API 143 standard The flange union between are extra long to allow for the addition of extra branch the first and second sections contains the ProfilerN and connections in the field if desired The standard meter a Y2 thick spacer plate to facilitate tube removal for tube has beveled outer ends Flanges or other end conshyinspection The outer end of section 2 contains the orishy nections are available on request fice flange or fitting The third or downstream section fol

Meter Tubes Catalog Numbers - 2 WI emor In9 bull Wit un or Itt ng2 1 th S Fitt 10 amp 12 h J i F i

Pressure Rating

Flange by Weld

(F1angnek)

Flange by Flange

(Flanged)

Weld by Weld

(Weldnek)

Flange by Weld

(Flangnek)

Flange by Flange

(Flanged)

Weld by Weld

(WeJdnek) 150 M011 M-101 NA M-021 M-201 NA 300 M-Q13 M-103 NA M023 M-203

NA 600 M-015 M-105 M-t85 M-025 M-205 M-285

2middot8 with Simplex 2middot12 with Orifice Flanges

Pressure Rating

Flange by Weld

weld by Weld

(Weldnek)CFlananekl 150 M-071 NA 300 M-073 NJA 6QfJ M-()75 M-705

Raised Face Weld Neck

NA - -

lM-30RW M-60RW

Two Section Meter Tube When USing Weldnek Fittings

Consult Factory for High Pressure Applications

PROFILERTM Flow Conditioning Plate

The Profiler has been tested and Shown to be in full compliance with the requirementS of API 143 April 2000 The Profiler both removes swirl

the tube bundle Available In flange mounted model only Also available In RTJ style on request

and creates a fully developed flow profile at the orifice Use of this unit allows shortened upstream straight pipe lengths of 17 diameters Beta ratio limit is 67 as with

-~---

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 18: Medidor de Flujo

Raised Face Weld neck

NA

3M-30RW

3M-60RW High Pressure

3M-90RW 3M-150RW 3M-250RW

DAN-3MT-3M-0801 August 2001

3 Section Meter Tube Catalog Numbers 2-12 with Senior Fitting 10 amp 12 with Junior Fittina

~

Pressure Rating

150

Flange by Weld

(Flangnek)

3M-011

Flange by Flange

(Flanged)

3M-101

Weld by Weld

(Weldnek)

NA

Flange by Weld

(Flangnek)

3M-021

Flange by Flange

(Flanged)

3M-201

Weld by Weld

(Weldnek)

NA

300 3M-013 3M-103 NA 3M-023 3M-203 NA

600 3M-015 3M-105 3M-185 3M-025 3M-205 3M-285

H~h Pressure 3 Section Meter Tubes 900 3M-016 3M-106 3M-186 3M-026 3M-206 3M-286

1500 3M-017 3M-107 3M-187 3M-027 3M-207 3M-287

2500 3M-018 3M-108 3M-188 3M-028 3M-208 3M-288

2middot8 with Simplex 2middot12 with Orifice Flanges Flange byPressure

WeldRating Weld by Weld (Flangnek) (Weldnek)

150 3M-071 NA 3M-073300 NA

600 3M-075 3M-705 High Pressure

3M-7063M-076900 3M-7071500 3M-077 3M-7083M-0782500 -

Two Section Meter Tubes When Usmg Weldnek Flttmgs

Senior and Simplex fittings are also available in 10000 psi rating in some sizes All units are also available with Ring Type Joint (RTJ) flanges on request Sizes larger than 12 available on request

PackingShipping Daniel bolts together all meter A SPECIAL NOTE The use of factory original Daniel tubes when size permits before shipment This saves parts will assure your Senior Junior and Simplex Orifice the user time and field labor costs Fittings are protectshy fittings will stay within original specifications and operate ed by heavy lumber and the tube flanges by special-cut properly protectors

PaintingCoating The Daniel standard paint is a basic enamel type Special coatings such as multi-coat

offshore systems are available on request

3~Section Meter Tube with Tube Bundle

~-----~ U ----~---------~=~~middotmiddotmiddotmiddot~middot t)middotmiddot-middot ~- - -0bull )00)00 1

I~IC--middotmiddotmiddot-middot -----shyshy-bullmiddotV ------- ~

~ - ~-

~

ii~pound bullbullbull ~

Standard lenAths Size un Upstream 0 Downstream V (vane location)

3 7-5 4-0 130 4 9~~9 4-0 130

6 14-8 5-0 t30

102410 60middot middot 130 1~ +1 2tYS Tq 130 JiIf

Note Straightening vanes are not available in 2line size (See Dald Profller DAN-1852middot 2M)

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Daniel meter tubes can be supshyplied in many combinations and configurations Any of the orifice fittings plate holders or orifice flanges can be included in a meter tube Each 3 section standard meter tube is equipped with a flange mounted tube bundle straightener In accordance with April 2000 API 143 and a 1h thick spacer to facilitate tube removal for inspection Downstreams are longer than minimum required to allow for field Installation of additional branch connections If required

To specify a 3 section meter tube use the designation 3M followed by the type orifice holding deVice Ex 4 600 3 section meter tube with flanged ends using a Senior fitting flangneck style is specified as 4-3M-015 The same unit with a weldneck style Simplex is specified as 4middot3M-705 When ordering specify pipe schedule and end configuration Larger size and custom meter tube designs are available on request

The Daniel Profilertrade three section meter tube is availshy lows and contains 2 branch connections Other or addi able with any style Senior or Junior orifice fitting Simplex tiona I connections can be supplied in this section on plate holder or orifice flanges The assembly contains an request These meter tubes are for use in any piping conshyinlet spool of tile minimum length determined during testshy figuration with beta ratios to 67 Downstream sections ing to the API 143 standard The flange union between are extra long to allow for the addition of extra branch the first and second sections contains the ProfilerN and connections in the field if desired The standard meter a Y2 thick spacer plate to facilitate tube removal for tube has beveled outer ends Flanges or other end conshyinspection The outer end of section 2 contains the orishy nections are available on request fice flange or fitting The third or downstream section fol

Meter Tubes Catalog Numbers - 2 WI emor In9 bull Wit un or Itt ng2 1 th S Fitt 10 amp 12 h J i F i

Pressure Rating

Flange by Weld

(F1angnek)

Flange by Flange

(Flanged)

Weld by Weld

(Weldnek)

Flange by Weld

(Flangnek)

Flange by Flange

(Flanged)

Weld by Weld

(WeJdnek) 150 M011 M-101 NA M-021 M-201 NA 300 M-Q13 M-103 NA M023 M-203

NA 600 M-015 M-105 M-t85 M-025 M-205 M-285

2middot8 with Simplex 2middot12 with Orifice Flanges

Pressure Rating

Flange by Weld

weld by Weld

(Weldnek)CFlananekl 150 M-071 NA 300 M-073 NJA 6QfJ M-()75 M-705

Raised Face Weld Neck

NA - -

lM-30RW M-60RW

Two Section Meter Tube When USing Weldnek Fittings

Consult Factory for High Pressure Applications

PROFILERTM Flow Conditioning Plate

The Profiler has been tested and Shown to be in full compliance with the requirementS of API 143 April 2000 The Profiler both removes swirl

the tube bundle Available In flange mounted model only Also available In RTJ style on request

and creates a fully developed flow profile at the orifice Use of this unit allows shortened upstream straight pipe lengths of 17 diameters Beta ratio limit is 67 as with

-~---

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 19: Medidor de Flujo

3~Section Meter Tube with Tube Bundle

~-----~ U ----~---------~=~~middotmiddotmiddotmiddot~middot t)middotmiddot-middot ~- - -0bull )00)00 1

I~IC--middotmiddotmiddot-middot -----shyshy-bullmiddotV ------- ~

~ - ~-

~

ii~pound bullbullbull ~

Standard lenAths Size un Upstream 0 Downstream V (vane location)

3 7-5 4-0 130 4 9~~9 4-0 130

6 14-8 5-0 t30

102410 60middot middot 130 1~ +1 2tYS Tq 130 JiIf

Note Straightening vanes are not available in 2line size (See Dald Profller DAN-1852middot 2M)

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Daniel meter tubes can be supshyplied in many combinations and configurations Any of the orifice fittings plate holders or orifice flanges can be included in a meter tube Each 3 section standard meter tube is equipped with a flange mounted tube bundle straightener In accordance with April 2000 API 143 and a 1h thick spacer to facilitate tube removal for inspection Downstreams are longer than minimum required to allow for field Installation of additional branch connections If required

To specify a 3 section meter tube use the designation 3M followed by the type orifice holding deVice Ex 4 600 3 section meter tube with flanged ends using a Senior fitting flangneck style is specified as 4-3M-015 The same unit with a weldneck style Simplex is specified as 4middot3M-705 When ordering specify pipe schedule and end configuration Larger size and custom meter tube designs are available on request

The Daniel Profilertrade three section meter tube is availshy lows and contains 2 branch connections Other or addi able with any style Senior or Junior orifice fitting Simplex tiona I connections can be supplied in this section on plate holder or orifice flanges The assembly contains an request These meter tubes are for use in any piping conshyinlet spool of tile minimum length determined during testshy figuration with beta ratios to 67 Downstream sections ing to the API 143 standard The flange union between are extra long to allow for the addition of extra branch the first and second sections contains the ProfilerN and connections in the field if desired The standard meter a Y2 thick spacer plate to facilitate tube removal for tube has beveled outer ends Flanges or other end conshyinspection The outer end of section 2 contains the orishy nections are available on request fice flange or fitting The third or downstream section fol

Meter Tubes Catalog Numbers - 2 WI emor In9 bull Wit un or Itt ng2 1 th S Fitt 10 amp 12 h J i F i

Pressure Rating

Flange by Weld

(F1angnek)

Flange by Flange

(Flanged)

Weld by Weld

(Weldnek)

Flange by Weld

(Flangnek)

Flange by Flange

(Flanged)

Weld by Weld

(WeJdnek) 150 M011 M-101 NA M-021 M-201 NA 300 M-Q13 M-103 NA M023 M-203

NA 600 M-015 M-105 M-t85 M-025 M-205 M-285

2middot8 with Simplex 2middot12 with Orifice Flanges

Pressure Rating

Flange by Weld

weld by Weld

(Weldnek)CFlananekl 150 M-071 NA 300 M-073 NJA 6QfJ M-()75 M-705

Raised Face Weld Neck

NA - -

lM-30RW M-60RW

Two Section Meter Tube When USing Weldnek Fittings

Consult Factory for High Pressure Applications

PROFILERTM Flow Conditioning Plate

The Profiler has been tested and Shown to be in full compliance with the requirementS of API 143 April 2000 The Profiler both removes swirl

the tube bundle Available In flange mounted model only Also available In RTJ style on request

and creates a fully developed flow profile at the orifice Use of this unit allows shortened upstream straight pipe lengths of 17 diameters Beta ratio limit is 67 as with

-~---

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 20: Medidor de Flujo

The Daniel Profilertrade three section meter tube is availshy lows and contains 2 branch connections Other or addi able with any style Senior or Junior orifice fitting Simplex tiona I connections can be supplied in this section on plate holder or orifice flanges The assembly contains an request These meter tubes are for use in any piping conshyinlet spool of tile minimum length determined during testshy figuration with beta ratios to 67 Downstream sections ing to the API 143 standard The flange union between are extra long to allow for the addition of extra branch the first and second sections contains the ProfilerN and connections in the field if desired The standard meter a Y2 thick spacer plate to facilitate tube removal for tube has beveled outer ends Flanges or other end conshyinspection The outer end of section 2 contains the orishy nections are available on request fice flange or fitting The third or downstream section fol

Meter Tubes Catalog Numbers - 2 WI emor In9 bull Wit un or Itt ng2 1 th S Fitt 10 amp 12 h J i F i

Pressure Rating

Flange by Weld

(F1angnek)

Flange by Flange

(Flanged)

Weld by Weld

(Weldnek)

Flange by Weld

(Flangnek)

Flange by Flange

(Flanged)

Weld by Weld

(WeJdnek) 150 M011 M-101 NA M-021 M-201 NA 300 M-Q13 M-103 NA M023 M-203

NA 600 M-015 M-105 M-t85 M-025 M-205 M-285

2middot8 with Simplex 2middot12 with Orifice Flanges

Pressure Rating

Flange by Weld

weld by Weld

(Weldnek)CFlananekl 150 M-071 NA 300 M-073 NJA 6QfJ M-()75 M-705

Raised Face Weld Neck

NA - -

lM-30RW M-60RW

Two Section Meter Tube When USing Weldnek Fittings

Consult Factory for High Pressure Applications

PROFILERTM Flow Conditioning Plate

The Profiler has been tested and Shown to be in full compliance with the requirementS of API 143 April 2000 The Profiler both removes swirl

the tube bundle Available In flange mounted model only Also available In RTJ style on request

and creates a fully developed flow profile at the orifice Use of this unit allows shortened upstream straight pipe lengths of 17 diameters Beta ratio limit is 67 as with

-~---

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 21: Medidor de Flujo

3-Section Meter Tube With Profilertrade

1-4(If--- - --- middot _ _ _ _ ~-~- O ----------=middotU-middotmiddotmiddotc----bull _ bull _ middot--------~~I

~ ~ ~ ~ ~

middotomiddotonr c e pmiddothii-(middot1f2middotr~middot $middot6aemiddotemiddotrDImiddot ~ r~1~ ~middot ~ r

~ ~

lt ~ ~

bull bull

~

bull ~ ~middot middot~middot middoto~rmiddot~ bullrbull ~frl~rbull l bullmiddot~m ~nmiddotr gmiddotmiddotmiddotJ bull middot ibull bull if middot ~g~in bullu bull middotbullbullbullIPa

Standard Lengths MU~ Upstreammiddot middot0 Downstream

~ 30 30

middot 3 middot middot 4-5 4() middotmiddotmiddot4 yS-9n 4h

J~ 8-8 5() -

11~7B 5Q middotmiddotmiddotmiddotmiddot8 bull n1 14~r 6()~ middot middotmiddotmiddotmiddotmiddotmiddot t2 ~ 17middot5 7(J

Lengths shown are suitable for any piping configuration and up to 67 beta ratio Reference API 143 April 2000 Daniel meter tubes can be supplied in many combinashytions and configurations Any Senior Junior Simplex or orifice flange can be Included in a meter tube Each Profller meter tube is equipped with a flange mounted Proftler and a 1h~ thick spacer to facilitate tube removal for inspection Upstream lengths shown are minimum but can be increased any amount to meet installation reqUirements Downstreams are longer than minimum to allow for field Installation of additional branch connecshytions if required

To specify a 3 section Profilermeter tube u~ the desigshynation 3MP followed by the type orifice holding device Example 4 600 3 section meter tube with beveled ends using a Senior fitting fiangneck style is specified as 4middot 3MP-015 The same unit with a weldneck style Simplex Is 4-3MP-705 When ordering specify pipe schedule and end configuration Larger size higher pressure ratshying and custom mater tube designs are available on request

-- - - shy

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 22: Medidor de Flujo

Stan~d~~er Tube Lengths with Profilertrade ~

PrOfUer+ 112- G bullplcer 112shy+38ets

I

(~~I_s I~I~i-lt~)~_ lt( shy 1----

mi ~

Outer ends beveled or ftansed

2 3() 4-5middot

4 I 6 8 8 middot

8 11-7 1012

14 Htmiddot illO 1$ 24_811

20 24

INLET SPOOL includingProfiler

j gskts and 12 tk spacer platemiddot Catalog ItS

2t~

3-2 4-10 6-6 8-2 91middot9 10-7

12~2 13-9 IS-3 15-5

UPSTREAM SPOOL DOWNSTREAM Flange face to orifice LENGTH

plate centerline Catalog U

9-8~ 101111

Cat810g D

3-0 4()

middotf ~C 4-0

lt ~bull N-4 ~ ~-

~ middotmiddotmiddotmiddotl ot~1shy

bullbullbull bullbull -I middotT middot ~middot middot ~

middotmiddotmiddotmiddotmiddotmiddotmiddot 1middot4middotmiddotmiddot H 12-7- ~ shy i~- ~4

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 23: Medidor de Flujo

o

FTIN

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 24: Medidor de Flujo

--2001

Daniel Publication Dan-1852

PROFILER trade Flow Conditioning Plate

The Daniel Profiler Flow Conditioning Plate provides an economical way to reduce uncertainty in orifice metering as outlined in API Part 2

Cost effective for new or existing meter tubes

11 Qualified by performance tests conducted to API standards

11 Field retrofittable for most meter runs

It Minimizes swirl and turbulence

Reduces meter-run lengths

Helps to the conditions necessary for a fully developed profile

It has been determined that the previously stated upstream location limits for flow conditioning plates are more restrictive than they should be Wheras it has been shown that the flow should be between 75 and 12D from the orifice installation of the flow conditioning can actually be anywhere from 75D OR MORE from the orifice as long as there is a minimum of 9 5D of additional pipe preceding the flow conditioning plate Test data supports this This information far more opportunity for customer field of tube bundles in locations The illustration below indicates the new information

Daniel Profilertrade

) ~

95D 95D or

allowed

17D minimum (std)

75D 75D or RrOgtr

allowed

EMERSON

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA

~ - -~~ ~--~----- EMERSON~

Process Management

DAN-1868-3M-1101

Page 25: Medidor de Flujo

The Daniel Profiler Flow Conditioning Plate has been successfully tested to the standards set by API 143 Part 2 Test results are available upon request or visit the Daniel wed site at wwwdanielcom (from Home Pagegt Productsgt Differential Productsgt Technical Papers)

Actual test include effects on a fully developed profile two 90deg elbows in perpendicular planes one gate valve (50 closed) and high swirl angle over 25 Additional test involved swirl at two beta values Reynolds number (Regt sensitivity and scaling

Dimensions (All in inches)

Flange type sizes 2 through 30 Larger sizes available on request

Standard material of construction 304 stainless steel Optional materials available

-----+ A 1--shyline Size

IIA Total Thickness

8 Flange 00

G Flange Thickness

0 Weight (Ibs)

2 05 362 025 075

rshy 2 12

3

05

05

412

5

025

025

1

15

4 05 619 025 2

Machine 6 075 85 025 5 to pipe B

schedule 8 1 1062 025 11

I 10 125 1275 025 19

12 15 15 025 31

1--~ 14

16

175

2

1625

185

025

025

42

63

18 225 21 025 89

20 25 23 025 122

-----+1C 1shy 24 3 2725 025 209

30 375 3375 025 407 Please supply line size schedule and special material requirements when requesting price For more information contact your Daniel representative or visit our website

Daniel Division Headquarters Houston Texas USA T (713) 467-6000 F (713) 827-3880 Calgary Alberta Canada T (403) 279-1879 F (403) 236-1337 Stirling Scotland - UK Mid-East amp AfricaT +44 01 786433400 F +44 01786 433401 Singapore - Asia Pacific T +65-777-8211 F +65-770-8001

USA Toll Free 1-8BB-FLOW-001 wwwdanlelcom

Daniel is a wholly owned subsidiary of Emerson and a part of Emerson Process Management

-uulS-- is a registered Trademark Printed in USA