Page 1: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور
Page 2: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

Dissertation

Effect of non Seismic Walls

On Moment Resisting Frames in buildings.

Can we neglect reinforce concrete walls like

(stairwells, elevator shafts and so forth)?

By:

Dr.Youssef Hamida

Consultant Structural Engineer

Aleppo Engineers Order

Syria - Aleppo

[email protected]

Web: www.dr-hamida.com

2

Page 3: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

Seminar Abstract – Non Seismic Walls

The performance of the Dual systems (frames and walls) in re-

sisting earthquakes.

And the efficiency of neglecting the walls (Reinforce con-

crete, masonry, partition, fill) and depending Completely on

the frames in resisting the seismic loads.

and what are the Effecting factors which will occur from

neglecting these walls ?

like (Rigidity – Eccentricity – Torsion – Period - Base Shear)

On the behave of the Moment resisting Frames

Can we neglect reinforce concrete walls like stairwells, ele-

vator shafts and so forth?

*And what are the behavior of these walls during the yielding

point for the steel in work stress stage uncracked section

[Elastic Response Parameters] and after the yielding point in

Plastic stage cracked section (Ultimate strength) since

*(Plastic Hinges) will occur in the Frames during plastic

stage And the frames shall peer all the entire seismic loads

And what are these Condition and arrangements to keep

the section walls in safety during plastic stage

so they can carry just the ordinary(D+L) axial loads.

Dose reinforcement for axial ordinary loads enough for these

walls from collapsing?

All these answers you will get it when you look at the Dis-

sertation

3

Page 4: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

2 Dissertation text

-Introductory

As it is well known to most of structural engineers who are

familiar with the types of structural systems for resisting

wind and seismic loads, they are called

Shear systems-such as:

1-Frames:

This is a frame system of rigid beams subjected to lateral

loads where the developed moments in the middle of the columns

are not existent And the shear forces will be distributed pro-

portionally with the moment of inertia of the columns and the

lateral displacements will be proportional to these forces

2-Shear walls:

These systems resist the lateral loads with the shear walls

whether these walls are separated or connected by beams.

The distribution of shear forces is proportional to the moment

of inertia of the cross sections of the walls; the displace-

ments in each floor or level are the result of the Flexural

deformations in the walls.

3-Dual systems

These systems are the result of combining the two latter

systems to resist the lateral load, in these systems the shape

of the deformations will differ from those in frames and walls

systems, where effecting interacted forces advantages of this

combination is that the frames support the walls at the top and

control their displacement. Besides, the walls support the frames

at the bottom and decrease their displacement In other words, the

shear force of the frames is bigger at the top than it is at the

bottom and it goes the other way round for the

walls occur and change the shape of shear and moment diagrams.

4

Page 5: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

-It has been mentioned in the international and local codes

that in case we have regular frames of beams and columns along

with shear walls to resist

the lateral loads, the resistance of these members (the

frames) to the lateral

loads can be neglected, and it will be considered in the

calculations only to

resist the vertical loads, but we should conform to the

codes conditions

relating to the minimum reinforcement

and the allowed displacement of these beams and columns

-We rarely find shear systems as complete shear walls

without regular frames

(beams and columns), or absolute frames without service

walls or elevator walls

5

Page 6: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

the purpose of our research

- And the purpose of our research is to find out if we can

neglect the presence of walls (concrete or masonry) if they

are together with the frame system,where the frame system re-

sists all the lateral shear forces, and the walls will be con-

sidered just to bear the vertical load, and what are the pro-

visions for these walls and their effect on the frames load.

-We will find the proper answer throughout our research and

experiments in this subject, and you can find the summary

of the research in the results and recommendations page

The reasons and the cause for choosing this research

and its importance, and whether it is done to fulfill an

engineering need or to solve an engineering problem that

helps in developing the engineering work.

3-Research topic Demonstration

3.1 The Dual system is the one that both shear walls and

frames participate in resisting the lateral loads resulting

from earthquakes or wind or storms, possibility to develop

plastic hinges

and the portion of the forces resisted by each one depends on

its rigidity modulus of elasticity and its ductility, and the

in its parts Knowing that the frame is a group of beams and

columns connected with each other by rigid joints that can re-

sist shear and moments, and the shear wall is considered as a

cantilever free on the top and fixed in the bottom.

55

Page 7: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

3.2 The structural resisting system might be only shear walls

for resisting the lateral load and we can neglect the regular

frames.

3.3 The structural resisting system might be only frames

for resisting the lateral load and it is called Moment

Resisting Frames In the case of shear walls with the moment

resisting frames can we neglect the effect of these walls, and

calculate the frames to resist the whole base shear

this is the subject of our research; the existence of some

shear walls with moment resisting frames, could it be

neglected and not taken into consideration for resisting the

lateral loads, which means to calculate them only as gravity

loads resisting members, and what are structural effects and

changes resulting from that.

6

Page 8: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

4.Purpose and benefit of the research

-Some complains and questions had come to the Engineering

Union-Civil Engineering department, about invalidating some

domestic and industrial buildings licenses where some

structural notes are present, and when there is a

contradiction between the structural requirements for the

buildings and the building manners or systems of the city mu-

nicipality where.

4.1 Elevator and service walls must be of reinforced

concrete, and that is to comply with the mechanical study,

fire resistance, and more other reasons.

4.2 Also to conform to the structural provisions of the city

municipality, the stair house walls should be of

reinforced concrete instead of using masonry walls,and be-

cause of the door openings and piers are in small

dimensions, it should be of reinforced concrete to bear the

vertical lo ads.

4.3 Since most of the industrial buildings, stores, shops

and halls or galleries are in the lower floors (base), shear

walls can’t be used to resist the seismic loads, so it is pre-

ferred to use moment resisting frames.

8

Page 9: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

4.4 Repeating the structural study with taking into

consideration the seismic study, and including these walls in

the study will cause increment in the

base shear because of decrement in (R); the Elastic Modulus of

the structural system. In addition, the use of computers,

modeling, and advanced programs might be a little hard to pro-

cure in regular or individual offices.

4.5 That’s why we needed to make researches and investigations

about a method or a study of possibility of neglecting the

shear or masonry walls and not considering them as

participants with the frames. Also neglecting the regular

frames and not considering them as participants with the shear

walls, and considering them as gravity loads resisting members

but with other conditions that we will see in the results of

our research.

9

Page 10: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

5-The determined basics for making the research:

To define the relationship and the effect of the shear walls

on the function of the

moment resisting frames, and to know if these walls can be

studied only for

resisting the gravity loads not the lateral load

5.1 It was necessary to go back to the theories and hypothe-

sizes of the interactive performance between frames and walls,

and we needed to seek the help of the theory of Professor

(Lain Macleod). The calculations and results have been checked

by the computer de pending on the international program

(ETABS). Due to the enormous number of analysis’s and experi-

ments according to the variety of floors and walls number and

dimensions of cross sections of the columns. We depended on a

local program (STAAD-ALARAB) for calculating the frames and

the shear walls depending on the theory and assumptions of

Professor Macleod relating to the interacted performance be-

tween the frames and the walls. The summary of this theory as

it came in the research symposium of Portland Cement institu-

tion

5.2 The dual system is the one that both frames and shear

walls contribute in resisting the lateral loads, where the

frame is a group of beams and columns connected with each oth-

er by rigid joints, and the frames bend in accordance with

(Shear Mode), whereas the deflection of the shear walls is by

a (Bending Mode) like the cantilever walls

10

Page 11: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

5.3 As a result of the difference in deflection properties

between frames and walls, the frames will try to pull the

shear walls in the top of the building while in the bottom,

they will try to push the walls, so the frames will resist the

lateral loads in the upper part of the building, which means

an increase shear walls will resist most of the vertical loads

in the lower part of the building in the dimensions of the

cross section area of the columns in the upper part of the

frame more than what it needs to resist the gravity loads

5.4 So the distribution of the lateral loads in the top de-

pends on the rigidity of the frames where we suppose a spring

support, whose rigidity equals the rigidity of the frames in

the top, and the reaction of this spring is the share of the

frames, and the rest is the share of the walls. So, the walls

are pinned or supported by the frames at the top and fixed at

the bottom and they are resisting the seismic loads

5.5 So we need to find out the value of this reaction at the

top which equals a point load as the share of the frames ac-

cording to the (Macloed Theory).

then the share of the frames will be distributed to each frame

due to its rigidity and position relating to the center of

mass taking into consideration the torsion and shear resulting

from torsion below And that is according to the laws and rela-

tions and factors mentioned

11

Page 12: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

6-Terminology:

Ac: cross section area of columns

B: length of the frame

C: width of column

D; depth of the beam

E: Young Modulus

Fg, Fm, Fn, FS: functions depending on the shape of the

seismic load

--------------7

H: total height of the wall

h: height of the column in every floor

Ib: moment of inertia of the beams in the nods or joints

Iw: moment of inertia of the walls

Kw: Shear rigidity of the walls

Kf: rigidity of the frames

--------- 7.1

---------- 7.2

Fs = ----------------- 7.3

W = total lateral load

∆ = total displacement in top

∆A = displacement in columns from axial load

∆B = displacement from moment

12

Page 13: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

---------------------------- 7.4

displacement of walls ------ 7.5

∆f = displacement of Columns --- 7.6

------ rigidity of the frames

----- rigidity of the walls

--------------- 7.7

W =-------- total shear forces

P =-------- share of Frames

P1= W-P ---share of the Walls

13

Page 14: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

7-Researches and experiments:

- The research has been done and the data has been changed to

follow the Second Static Method for calculating the Base Shear

according to the Syrian Code and The American Code: (Uniform

Building Code, UBC) according to the law

= total base shear

7.1 The local program (STAAD-ALARAB) and ETABS have been

adopted to check and calculate the internal forces resulting

from neglecting the shear walls.

7.2 Thirty five typical space and plane cases have been

chosen. In every case, the constants and dimensions are

changed to obtain the maximum stresses and forces and that is

according to the tables, calculations and the results attached

in the end of the research.

7.3 For the number of the floors, we studied from one

floor cases till twelve floor cases.

Three cases have been chosen to get maximum

torsion and its effect on the frame, and that is by

the types of the walls and their positioning with respect to

the center of mass

7.4 A case of one wall with frames different in rigidity

has been studied, with different floors for different cases

with eccentricities:

e = l / 2 e = l / 4 e = 0

14

Page 15: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

7.5 Also the procedures are repeated for the case of two

walls for different number of floors and different examples

7.6 Also the procedures are repeated for the case of three

walls for different

number of floors, different types and rigidities

of frames and different eccentricities

7.7 Also in the research, a case of only frames without

shear walls has been studied, then we started to insert one

shear wall, then we increased the number of walls to two then

to three. Also for finding the eccentricity and increasing it

to the maximum value predicted Through the research results

and the attached tables, some important observations can be

noted, and corrections to some wrong concepts can be done for

the colleagues of engineers about the relation between the

frames and walls.

7.8 The most significant observation and the correction to

the wrong belief is that increasing the number of shear walls

and duplicating its area doesn’t duplicate the share of the

walls, but it stays almost the same as there is only one shear

wall, the increase is almost insignificant (about 15%) and it

comes from the increase of base shear resulting from the in-

crease in rigidity of the walls and the decrease of the dynam-

ic period, which means that the frames takes its share from

the base shear in the top then the rest is distributed (in the

bottom on the existed walls (one or two or three….etc.) And

that is what we observed in the research results, that is ex-

isting of a number of walls and then neglecting them is better

and gives less shear and bending stresses than the case of one

wall which is considered to be neglected

15

Page 16: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

7.9 We found out through the results that the frame’s shear

if there is no walls (the Moment resisting frames case) is

bigger than what it is in the case of frames and neglected

walls, because the torsion shear which is caused by

theeccentricity of the neglected walls, and which is added to

the eperipheral frames’ shear is smaller than the shear that

the walls take from the peripheral frame with the maximum tor-

sion.

7.10 also noticed the increase of the base shear when

there are walls rather than the case of no walls (only frames)

and that is because of the decrease of the dynamic period for

the increase in the rigidity of the Dual system and

thedecrease of the factor(R)in the denominator of the base

shear wall

7.11 In the attached drawing of the (interactive-mutual)

performance, we noticed that in the case of only two shear

walls without a frame, the base shear is distributed equally

in the top and bottom in the walls. And if there is one frame

with those two walls, we see that the share of the walls is

maximum in the bottom, and the share of the frame is zero in

the top and the bottom but maximum at the height (0.8 H), and

that is the hypothesis of Prof. Macloed, which is to put a

constant point load equals to the maximum shear which occurs

at the height (0.8-0.95) of the total height

7.12 Referring back to the results table of the program STAAD-

ALARAB and ETABS for the internal forces or stresses and Rein-

forcement

16

Page 17: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

7.13 we notice that it is taken into consideration:

-the dynamic period, the static period, ductility factor (Rw),

accidental eccentricity of walls positioning, ratio of frames

and walls shares, modifying the value of ductility factor (Rw)

according to that ratio, also calculation of the base consid-

ering the maximum case. shear V for every case and

7.14 we noticed from the table that the maximum share of

the frames in case of no walls (Moment resisting frames) is

larger than the case of frames with walls, for example:

8-Comparison and results:

Research example No#5:

Floor number: 7

The columns: 40 X 60

The walls: L=3,00 m

V= 61 t without walls

V= 44.46 t in case of one wall with maximum eccentricity

61 > 44.46 accepted

8.1 Also we notice from the results of ETABS:

That the shear and flexural stresses are maximum for one

shear wall, also we noticed that the minimum reinforcement for

shear and bending is adequate, so these walls can be neglected

and designed only for the gravity loads, if the number of

floors is less or equal to twelve floors.

17

Page 18: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

8.2 We noticed when the number of the floors is more than

twelve, and the minimum reinforcement is not adequate here, we

differentiate two cases:

8.2-1 When the flexural reinforcement is not adequate, the

walls are safe, because when the walls enters the plastic

situation, the frames will intervene and take the loads from

these walls and the walls will crack but not collapse, or it

will lose its rigidity and not resist any lateral loads

8.2-2 When the shear reinforcement is not adequate these

walls will collapse by shear, and its breaking will be brittle

so it should it should be calculated, or we should neglect its

resistance to the vertical loads by putting beams over them.,

9-Results and recommendations

9.1 It is possible to neglect the walls and do not

consider them as participants with the moment resisting fames

in resisting the lateral loads and to consider that all the

lateral loads as base shear or wind loads are going to be re-

sisted only by the frames according to

9.2 The moment resisting frames is not affected by neglecting

the walls when the walls do not take part with the frames in

resisting the loads, on the contrary, the safety factor for

the frames becomes bigger and the shear resisted by the frames

is less than what it was when the frames were alone

9.3 When the number of the building’s floor is equal or less

than 12 floors, (n<12), the walls can be neglected provided

that they are qualified to bear the only vertical loads, and

the minimum reinforcement is adequate for flexural and shear

18

Page 19: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

9.4 When the number of the building’s floor is more than

12 floors, (n>12), it is possible to neglect the participation

of the walls with the frames, provided that we should consider

finding alternative members to the walls for resisting the

vertical loads like beams or the frames itself, so when we put

beams on top of the walls or any other structural members to

transfer the vertical loads from these walls to the beams and

columns It is adequate to use the minimum reinforcement for

flexure al and shear stresses.

9.5 from(Tab-4,Tab-5)we find the ductility factor(R) decrease

to (7) instead of (8) and the base shear(v)increase (18%)

Because of affect walls stiffness.

10 conclusion

10-1 in ordinary building less than 12 story n<12 the service

walls like {stairwells, elevator shafts and so forth} can be

neglected to share frames in resisting seismic

10-2 the total base shear will take by frames after degreasing

The factor of ductility ,one degree or increasing the base

shear on frames 18%

10-3 seismic minimum reinforcement ably in both direction

As the code says.

19

Page 20: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

REFERENCES:

- The Arabic Syrian Code and its appendixes in resisting the seismic loads.

- The American codes: UBC-ACI

- Shear wall-frame interaction

by :I.A. Macloed

-Seismic design

by :D.T. Derecho

-STAAD-ALARAB, walls and frames

-by : D r . Youssef Hamida

-Interaction of shear walls and frames

By: Khan and Sbarounis

-Concrete shear walls combined with rigid frames

By: Cardan Bernard

-Multistory frames and interconnected shear walls

American concrete institute

By Firschman prabhu

-Design of Multistory reinforced concrete building for earthquake motions

-Shear wall design philosophy

By : Portland Cement Association

20

Page 21: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

ACI committee symposium paper by Thomas Paulay

-An inelastic approach to seismic design

by: American Society of Civil Engineering

-Response of multistory structures to lateral forces

by: Cardenas, Alex

-Symposiums and lectures of Engineers Union, Aleppo Branch

Resisting the seismic loads by walls and frames.

By: D r . Youssef Hamida

-Symposiums and lectures of Engineers Union, Damascus Branch

Analyzing and designing of buildings for Earthquakes

By: D r Karameh Baddorah - Dr. Zein-Aldeen -Dr. Alhessen

Structures dynamics and seismic engineering

By: D r Samara

21

Page 22: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

FFrraammeess ++ oonnee wwaallll

2222

Page 23: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

32

Page 24: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

Etabs

Frames + two walls+ Eccentricity

42

Page 25: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

Etabs

Frames + two walls

52

Page 26: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

Frames only

62

Page 27: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

Bending moment (Frames +one wall )

Etabs program

72

Page 28: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

Shear (Frames +one wall

Etabs program

82

Page 29: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

Bending moment (Frames +two wall) 12 stories

Etabs program

29

Page 30: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

oriesReinforcement 12 st

Etabs program

30

Page 31: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

staad alarab-result

dynamic

Static design

Stories

period

period

period T=

Wall from

5

DT ST 1.4*Ts<

DT ductilit

y mass center

Eccentricity

Base Shear

Frames

Columns Name

DT sT T wR a e V %

Share

60X60 Frames )x(

50.6 0.63 0.65 8 0 0 58.62 100%

wall 60.71

20x300 cm Frames

)y( 0.61 0.63 0.61 7 0 0 69.4

100%

69.4

Frames

0.5 0.42 0.5 7.5 0 0 80.8 50%

one wall 40.4

+Framese 0.47 0.42 0.47 7.5 7.5 0.71 85.87

50%

One wall 42.87

Frames

0.48 0.42 0.48 7 0 0 90.18 45%

Tow walls

41.03

Frames +e

0.45 0.42 0.45 7 7.5 1.04 96.7 45%

Tow walls

44

Story

dynamic

Static design

Wall from

5

period

period

period T=

ductility

mass center

Eccentricity

Base Shear

Frames

Columns Name DT ST

1.4*Ts<

DT wR a e V %

Share

40X60 Frames (x)

0.67 0.63 0.67 8 55.15 100%

wall 55.15

20x300 cm Frames

(y) 0.65 0.63 0.65 7 67 100%

67

Frames +

0.53 0.42 0.53 7 0 0 81.88 49%

one wall 0.284

Frames+e 0.5 0.42 0.5 7 7.5 0.79 87.26 49%

One wall 42.93

Frames+

0.51 0.42 0.51 7 0 0 85.65 44%

Tow walls 38.11

Frames +e

0.47 0.42 0.47 7 7.5 1.15 91.95 44%

Tow walls 40.92

4 – Table

staad alarab-result

3311

Page 32: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

Story

dynamic

Static design

Wall from

5

period perio

d period

T= ductilit

y mass

center Eccentrici

ty Base Shear

Frames

Columns Name

DT ST 1.4*Ts<

DT wR a e V

% Share

30X80 Frames(x)

0.71 0.63 0.63 8 0 0 53.37 100%

wall 53.37

20x300cm Frames

(y) 0.66 0.63 0.63 7 0 - 65 100%

65.81

Frames

0.55 0.42 0.55 7 0 0 79.11 49%

one wall 38.38

Frames+e 0.51 0.42 0.51 7 7.5 0.84 84.8 49%

One wall 41.42

Frames

0.52 0.42 0.52 7 0 0 83.3 44%

Tow walls 36.6

Frames +e

0.49 0.42 0.49 7 7.5 1.21 89.51 44%

Tow walls 39.32

Stories

dynamic

Static design

Wall from

7

period perio

d period

T= ductilit

y mass

center Eccentrici

ty Base Shear

Frames

Column Name

DT ST Ts<1.4*

DT wR a e V

% Share

40X60 Frames )x(

0.87 0.81 0.87 8 61 100%

wall 61

20 x 300 cm Frames

(y) 0.82 0.81 0.82 7 74 100%

74

Frames

0.7 0.54 0.7 7.5 0 0 80.62 52%

one wall 41.82

Frames+e 0.66 0.54 0.66 7.5 7.5 .430 85.7 52%

One wall 44.46

Frames

0.69 0.54 0.69 7 0 0 87.81 49%

Tow walls 43.1

Frames +e

0.64 0.54 0.64 7 7.5 0.52 89 41%

Tow walls 36.56

5 – Table

32

Page 33: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

staad alarab-result

Story

dynamic

atiStc design

Wall from

10

period perio

d period

T= ductilit

y mass

center Eccentrici

ty Base Shear

Frames

Columns Name DT ST

1.4*Ts<

DT wR a e V %

Share

40X60 Frames(x)

1.18 1 1.18 8 66.83 100%

wall 66.83

20x300 cm Frames

(y) 1.11 1 11.1 7 78.22 100%

78.22

Frames +

1.02 0.7 0.98 7.5 0 0 82.39 53%

one wall 44

+Framese 0.99 0.7 0.98 7.5 7.5 0.21 83.39 53%

One wall 44

Frames

0.92 0.7 0.92 7.5 0 0 88.14 52%

Tow walls 45.78

Frames +e

0.87 0.7 0.87 7 7.5 0.33 92.83 52%

Tow walls 48.2

Story

dynamic

Static

design

Wall from

12

period perio

d period

ductility

mass center

Eccentricity

Base Shear

Frames

Column Name

DT sT T wR a e V %

Share

60X60 Frames (x)

1.27 1.2 1.23 8

80.2 100%

wall 80.2

20x300 cm Frames

(y) 1.23 1.2 1.23 7

84.85 100%

84.85

Frames+

1.04 0.81 1.04 7.5 0 0 93.81 54%

one wall 50.6

+Framese 0.98 0.81 0.98 7.5 7.5 0.15 99.6 0.54%

One wall 53.4

Frames +

1.02 0.81 1.02 7.5 0 0 95.3 53%

Tow walls 50.33

Frames +e

0.96 0.81 0.96 7.5 7.5 0.24 101.4 53%

Tow walls 53.6

6 – Table

33

Page 34: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

staad alarab-result

walls frames-Etabs

Name

Max

Shear

Max

Bending

ar She

stress

Shear

reinf Tension steel Ratio

Research ton/m

ton.m tu kg/cm2 All

Stories Typical Story

Base Story

A Frames + 38.28 202 6.38

Min Ratio

Min Ratio 0.008

Story one wall

5 Frames

+e 27 159 4.50

Min

Ratio Min Ratio

0.008

Column One wall

60X60 Frames + 30 175 5.00

Mini Ratio

Mini Ratio 0.008

wall Tow walls

20x300 cm Frames

e+ 26.61 132 4.44 Min

Ratio Min Ratio 0.008

Tow walls

walls frames-Etabs

Name

Max Shear

Max Bending

ar Shestress

Shear rein Tension steel Ratio

Research ton/m

ton.m tu kg/cm2

All Stories

Typical Story

Base Story

B Frames 44 233 7.33

Min

Ratio Min Ratio 0.008

Story one wall

5 Frames

e+ 26.41 168 4.40 Min

Ratio Min Ratio 0.008

nColum One wall

40X60 Frames 31.3 187 5.22

Min Ratio

Min Ratio 0.008 wall s Tow walls

20x300 cm

Frames e+ 25.3 125 4.22

Min Ratio

Min Ratio 0.008

Tow walls

walls frames-Etabs

Name

Max Shear

Max Bending

shear stress

ar Shereinf Tension steel Ratio

Research ton/m

ton.m tu kg/cm2

All Stories

Typical Story

Base Story

C Frames 38 212 6.33 Min

Ratio Min Ratio 0.008 Story one wall

5 Frames

+e 22

150 3.67 Min

Ratio

Min Ratio 0.008

Column One wall

30X80 Frames 28 176 4.67

Min

Ratio Min Ratio 0.008

wall Tow walls

20x300 cm

Frames

e+ 25 132 4.17 Min

Ratio Min Ratio 0.008

Tow walls

7 - Table

43

Page 35: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

staad alarab-result

walls frames-Etabs

Name

Max Shear

Max Bending

shearstress

Shear reinf Tension steel Ratio

Research ton/m

ton.m tu kg/cm2 All Stories

Typical

Story

Base

Story

D Frames 44 226 7.33 Min Ratio Min Ratio 0.008

Stories one wall

7 Frames

+e 26.5 161 4.42 Min Ratio Min Ratio 0.008

nColum One wall

40X60 Frames 32.5 186 5.42 Min Ratio Min Ratio

0.008

wall Tow

walls

20x300 cm

Frames e+ 30 141 5.00 Min Ratio Min Ratio

0.008

Tow walls

walls frames-Etabs

Name

Max Shear

Max Bending

shear stress

r Sheareinf

Tension steel Ratio

Research ton/m

ton.m tu kg/cm2 All Stories

Typical Story

Base Story

E Frames 44.42 234 7.40 Min Ratio Min Ratio 0.008

Story one wall

10 Frames

+e 25.3 159 4.22 Min Ratio Min Ratio 0.008

Column ll One wa

40X60 Frames 32.4 191 5.40 Min Ratio Min Ratio 0.008

wall Tow

walls

20x300 cm

Frames +e 31 149 5.17 Min Ratio Min Ratio 0.008

Tow walls

walls frames-Etabs

Name

Max Shear

Max

Bending

Shear stress

Shear reinf

ension Tsteel Ratio

Research ton/m

ton.m tu kg/cm2 All Stories

Typical

Story

Base

Story

F Frames 44.5

236 7.42 Min Ratio Min Ratio 0.008

Story one wall

12 Frames

+e 31.1

188 5.18 Min Ratio Min Ratio 0.008

Column One wall

60X60 Frames 31.2 187 5.20 Min Ratio Min Ratio 0.008

wall Tow

walls

20x300 cm

Frames +e 27 153 4.50 Min Ratio Min Ratio 0.008

Tow walls

8 – Table

53

Page 36: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

Seismic forces

yMax Eccentricit

Tx= 0.609

Ty= 0.609

Calculation

period

Ctx = 0.0731

Cty = 0.0731

Coefficient

Ftx= 0.00 Point Load

Fty = 0.00 Ft =0.07 T* V

X MR = 7.50

Y MR= 7.50

Mass Center

X CR= 7.50

Y CR= 7.50

Rigidity Center

Mtx = 45.53

Mty = 45.53

orsionT

Mx = 0.72 inelastic Drift

My = 0.72 M=0.7 R DS

9-Tab

63

Page 37: Seminar abstract non seismic walls -مقاومة قوى الزلازل بالإطارات فقط واهمال جدران الكور

Seismic forces

base Shear

Walls Share -Vy

60.71 0.00

Frames %

Frames

Share

100.00 60.71

Ft) Wx hx / s Wi hi-Fx = (V

Base Shear distribution

FX FY

20.24 20.24

16.19 16.19

12.14 12.14

8.09 8.09

4.05 4.05

60.71 60.71