alcatel drie operation manual - university of...

19
1 of 1 Alcatel 601E DRIE (Deep Reactive Ion Etcher) Operation Manual Description: The Alcatel 601E utilizes the Bosch process to provide deep etches into silicon substrates. With proper substrate preparation and handling the system can completely etch through the silicon. Current configuration is for 100 mm silicon wafers with a single flat. After a substrate has been manually loaded into the Loadlock all transfer and processing is completed under automatic computer control.

Upload: ngonhu

Post on 02-Apr-2018

243 views

Category:

Documents


6 download

TRANSCRIPT

Page 1: Alcatel DRIE Operation Manual - University of …research.engineering.ucdavis.edu/.../2013/08/AlcatelDRIE.pdf1 of 1 Alcatel 601E DRIE (Deep Reactive Ion Etcher) Operation Manual Description:

1of1

Alcatel601EDRIE(DeepReactiveIonEtcher)OperationManual

Description:

TheAlcatel601EutilizestheBoschprocesstoprovidedeepetchesintosiliconsubstrates.Withpropersubstratepreparationandhandlingthesystemcancompletelyetchthroughthesilicon.Currentconfigurationisfor100mmsiliconwaferswithasingleflat.AfterasubstratehasbeenmanuallyloadedintotheLoadlockalltransferandprocessingiscompletedunderautomaticcomputercontrol.

Page 2: Alcatel DRIE Operation Manual - University of …research.engineering.ucdavis.edu/.../2013/08/AlcatelDRIE.pdf1 of 1 Alcatel 601E DRIE (Deep Reactive Ion Etcher) Operation Manual Description:

2of2

Safety:1. Beforeoperatingthistool,usersmustbetrainedandcertifiedbyLabstaff.2. MakesurethatasubstrateisloadedandtheVacuumLoadlocklidisdownbefore

startinganyprocess3. ARedAlarmstatuslightindicatesthesystemhas/hadaconditionthatmaynot

allowprocessing.Theusershouldusecautionuntilthecauseofthealarmisdetermined

4. IftheAlarmwillnotremainoffafteracknowledgingcontactthestaffatthephonenumberlistedbelow.

5. IfGreenOnstatusindicatorisoffandRedstopstatusindicatorisondonotattempttostart.DiscontinueusingthesystemandcontacttheNCNCstaff

EmergencyMachineOff(EMO)

UsetheEMOButtononlyifthereisasafetyhazardorserioussystemfailure.Ifthereiswateronthefloorbetweenyouandthesystemleaveandcontactthelabstaff.

1. PushRedEMO(EmergencyMachineOff)button2. CallNCNCstaff

a. LabPhone 2‐9831

EMOBUTTON

(GUI)Graphical

UserInterfacecandisplay

detailedSystem

Status

ControlButtonsandStatus

Indicators

Page 3: Alcatel DRIE Operation Manual - University of …research.engineering.ucdavis.edu/.../2013/08/AlcatelDRIE.pdf1 of 1 Alcatel 601E DRIE (Deep Reactive Ion Etcher) Operation Manual Description:

3of3

SystemOperation

InitialSystemChecks:

1. Checkthelogbooktoverifysystemcondition.IfsystemisdownandwasnotnotedintheNCNCmailpleasesendanE‐Mailupdatingthestaffandusergroup.

2. Notethealarmstatus.3. Verifythatsystemchambervacuumisinthex.x‐6mBarrange.4. Loadlockshouldbevented.5. OpenLoadlockandcheckforsubstrate.

GUI(GraphicalUserInterface)

1. ProvidesVideodisplayofControlComputerSensorandStatusinformation,functionwindowsanddatainputfields.

OpenLoadlock

Page 4: Alcatel DRIE Operation Manual - University of …research.engineering.ucdavis.edu/.../2013/08/AlcatelDRIE.pdf1 of 1 Alcatel 601E DRIE (Deep Reactive Ion Etcher) Operation Manual Description:

4of4

PrepareforEtching

1. SelectUserButtonusingTrackballandleftclickkey.(seeAppendix)

2. UsingTrackballandleftclickkeySelectLogintoopenLoginWindow.

UserButton

LoginButton

Page 5: Alcatel DRIE Operation Manual - University of …research.engineering.ucdavis.edu/.../2013/08/AlcatelDRIE.pdf1 of 1 Alcatel 601E DRIE (Deep Reactive Ion Etcher) Operation Manual Description:

5of5

3. UsingTrackballandKeyboardEnteryourusernameandpasswordthenclickOK.

4. UseTrackballtoopenAlarmscreenifactive.5. RecordanyalarmothertheHeaterstandbymessageintheLogbook.6. PleasenotifyDanHaskell4‐6587ofallalarmsotherthanHeaterstandby.7. AcknowledgetheAlarm(s).8. WaitoneminuteifAlarmremainsoff,systemcanbeusedforprocess.9. IfAlarmreturns,Logoffandplaceamachinedownnotificationonthesystem.

RecordthealarmmessagetextinthelogbookandE‐mailNCNCthatthesystemisdown.

10. IfnoactivealarmsarepresentopentheLoadlockandplacesubstratewithoneflatorientedtothelocatorscrews.

SubstrateLoaded

UserName

Password

Page 6: Alcatel DRIE Operation Manual - University of …research.engineering.ucdavis.edu/.../2013/08/AlcatelDRIE.pdf1 of 1 Alcatel 601E DRIE (Deep Reactive Ion Etcher) Operation Manual Description:

6of6

11. CloseLoadlockLidandproceed.

SelectRecipe

1. UsingTrackballselectGO!Process.

ClosedLoadlock

ProcessSelectionWindowButton

Page 7: Alcatel DRIE Operation Manual - University of …research.engineering.ucdavis.edu/.../2013/08/AlcatelDRIE.pdf1 of 1 Alcatel 601E DRIE (Deep Reactive Ion Etcher) Operation Manual Description:

7of7

2. UsingTrackballSelectthedropdownlist.3. ScrollthroughthelistandclickondesiredProcess.

4. EnableDatalogging“recommended”.

EtchSubstrate

1. SelectGO!RunbuttontostarttheProcess.2. ThescreenwillchangetotheProcessControldisplay.

BlueIndicatesSelectedProcess

Dataloggingshowndisabled

Run/StartButton

RecipeStepsofSelectedProcess

DropDownList

Page 8: Alcatel DRIE Operation Manual - University of …research.engineering.ucdavis.edu/.../2013/08/AlcatelDRIE.pdf1 of 1 Alcatel 601E DRIE (Deep Reactive Ion Etcher) Operation Manual Description:

8of8

3. SystemwillpumpdowntheLoadlockthentransportthewaferintotheProcessChamber.

4. MonitorHeliumflowandtemperatureforatleast2minutesbeforeleaving.Heliummayriseto10sccmatthebeginningofthestepbutshouldsettletobelow3sccminthefirstminuteofflow.HeliumFlowsover3sccmcancauseprocessshifts.ThesystemshouldgenerateaWarningandanAlarmthatshouldhaltprocessiftheHeliumflowsexceed10sccm.

5. ObservetheProcessControlscreenforatleast2minutesbeforeleavingthesystem.6. VerifythatsensordisplaysarereachingrecipeSetpointsandnoAlarmshave

occurred.

Processelapsedtime

HeliumFlowSensorValue

CurrentStepField

Page 9: Alcatel DRIE Operation Manual - University of …research.engineering.ucdavis.edu/.../2013/08/AlcatelDRIE.pdf1 of 1 Alcatel 601E DRIE (Deep Reactive Ion Etcher) Operation Manual Description:

9of9

AfterEtchisComplete

1. WhenallprocessstepsarecompletethesystemwillplacethesubstrateintheLoadlock.TheLoadlockisventedtoAtmospherethenanEndofprocesswindowwillbedisplayed.

2. OpenLoadlockandremovesubstrate.3. Inspectthesubstratefordamage.Ifanybreakageorpiecesaremissingdiscontinue

usingthesystem.Logoffandplaceasystemdownnotificationonthesystem.SendE‐mailnotificationtoNCNCgivingthesystemstatus.

4. CloseEndofProcessWindow.5. IflastwaferLogoff.6. CloseLoadlocklidbeforeleavingsystem.7. UpdateLogbook.

CloseEndofprocessbutton

Page 10: Alcatel DRIE Operation Manual - University of …research.engineering.ucdavis.edu/.../2013/08/AlcatelDRIE.pdf1 of 1 Alcatel 601E DRIE (Deep Reactive Ion Etcher) Operation Manual Description:

10of10

APPENDIX:

Trackball:

1. M1isequivalenttoLeftMouseButton.2. M3isequivalenttoRightMouseButton.3. RollingTrackballshouldmoveindicatorarrowonscreen.

FrontControlPanel:

1. StopButton(RedIndicator)lampshouldbeoff.Donotpressbutton,unusedduringnormaloperation.

2. StartButton(greenindicator)shouldbeonduringnormaloperation.IfGreenindicatorisoffdonotattempttorestartsystem.

3. EmergencyStopPushbutton.OnlyusedinEmergenciesremovesElectricalpowerfromthesystem.

4. AlarmIndicator(Red)activewhensystemisnotreadytorunaprocess.

M1

M3

Trackball

EmergencyStop

Pushbutton

StartButton(GreenIndicator)

StopButton(RedIndicator)

AlarmIndicator

(red)

Page 11: Alcatel DRIE Operation Manual - University of …research.engineering.ucdavis.edu/.../2013/08/AlcatelDRIE.pdf1 of 1 Alcatel 601E DRIE (Deep Reactive Ion Etcher) Operation Manual Description:

11of11

UserInterfaceSystemScreen:

1. RedindicatesInactiveorClosed.GreenindicatesActiveorOpen.2. TimeandDatefieldsareactiveonallpages.3. LoadlockPressuredisplay.OnlyattempttoopenwhendisplayreadsAtm.4. SourceRFStatusfielddisplayspowerdeliveredvs.powerreflected.5. ProcessChamberHighVacuumSensordisplayssystembasepressure.During

processtheassociatedIsolationValvewillcloseandthesensordisplaygoestooff.

LoadlockPressure

TimeandDateDisplay

SourceRF

StatusDisplay

ProcessChamberHigh

VacuumSensorDisplay

ProcessChamberHighVacuum

SensorIsolationValve

Page 12: Alcatel DRIE Operation Manual - University of …research.engineering.ucdavis.edu/.../2013/08/AlcatelDRIE.pdf1 of 1 Alcatel 601E DRIE (Deep Reactive Ion Etcher) Operation Manual Description:

12of12

6. LoadlockhasnoLidclosedorwaferpresentsensors.7. ManometerSensorFielddisplaysChamberpressureduringProcesssteps.8. VATValvecanisolatethechamberormovetocomputercontrolledpositionto

varychamberpressure.9. LoadlockTurboPumpStatusDisplayGreenindicatesonandatoperatingspeed.

ThistypicallywillgoRedbrieflyduringLoadlockpumpdown.10. LoadlockRoughingPumpGreenindicatesonandproperpressurelevelto

supporttheTurboPump.11. SubstrateHolderRFStatusfielddisplayspowerdeliveredvs.powerreflected

andBiasvoltagedeveloped.

VATValve

LoadlockRoughing

PumpStatusDisplay

LoadlockTurboPumpStatusDisplay

SubstrateHolderRF

PowerStatusField

LoadlockManometerSensor

Field

Page 13: Alcatel DRIE Operation Manual - University of …research.engineering.ucdavis.edu/.../2013/08/AlcatelDRIE.pdf1 of 1 Alcatel 601E DRIE (Deep Reactive Ion Etcher) Operation Manual Description:

13of13

12. WaferIcondisplayslastexpectedplacementposition.WhensystemisinidlemodeWaferIconisshowninLoadlock.

13. ProcessTurboPumpstatusDisplayshouldremainGreen.DuringnormaloperationRedisanAlarmcondition.

14. TurboNitrogenValveisonlyopenedusedduringmaintenance.15. ProcessTurboPumpIsolationvalveshouldremainopen(Green)duringnormal

operation.16. Processchamberroughingpumpprovidesroughvacuumpumpingduring

systemstartup.TypicallythechamberroughpumpprovidesexhaustvacuumfortheProcessTurbopump.

WaferIconshownasYellowRectangle

ProcessChamberTurboPumpStatusDisplay

ProcessChamberTurboPumpIsolationValve

ProcessChamberRoughingPumpStatus

Display

TurboNitrogenValve

Page 14: Alcatel DRIE Operation Manual - University of …research.engineering.ucdavis.edu/.../2013/08/AlcatelDRIE.pdf1 of 1 Alcatel 601E DRIE (Deep Reactive Ion Etcher) Operation Manual Description:

14of14

17. LowerSubstrateHolderVacuumValvecontrolsVacuumsupplytoLowerSubstrateHolderAssembly

18. HeVacuumValveactivatestopumpHeliumfrombacksideoftheSubstratebeforeclampisreleased.

19. ProcessChamberTurboBypassValveonlyusedduringmaintenance.20. SubstrateHolderTemperatureSensorDisplay21. HeSupplyValvedeliverstheMassFlowControlleroutputtotheBacksideofthe

substrate

HeSupply

Valve

LowerSubstrateHolder

VacuumValve

HeVacuumValve

ProcessChamber

TurboBypassValve

SubstrateHolder

TemperatureDisplay

Page 15: Alcatel DRIE Operation Manual - University of …research.engineering.ucdavis.edu/.../2013/08/AlcatelDRIE.pdf1 of 1 Alcatel 601E DRIE (Deep Reactive Ion Etcher) Operation Manual Description:

15of15

22. LoadlockN2valve.SuppliesN2duringLoadlockventtoAtmosphere.23. LoadlockVacuumValveusedtopumpLoadlockforsubstrateVacuumtransport.

Valveisclosed(red)whenLoadingorUnloadingLoadlockatatmosphericpressure.

24. HeMFC(MassFlowController)displaysHeflow.IfHeflowreadingsexceed3sccmexpectprocessshifts.Flowsabove10sccmshouldgenerateawarningoralarm

25. HePressuresensor.NormalpressureshouldmatchrecipeSetpointof1.0E‐1mBar.

LoadlockN2Valve

LoadlockVacuumValve

HeMFC(MassFlowController)Flowdisplay

HePressureSensorDisplay

Page 16: Alcatel DRIE Operation Manual - University of …research.engineering.ucdavis.edu/.../2013/08/AlcatelDRIE.pdf1 of 1 Alcatel 601E DRIE (Deep Reactive Ion Etcher) Operation Manual Description:

16of16

26. MachineOperatingMode,shouldalwaysbeinLocal.27. ProcessLibraryisassignedtouserlistedhere.28. UserLogDisplayliststheUserthatispresentlyloggedin.29. CommunicationstatusdisplaysstatusofthelinkbetweentheUserinterfaceand

the(PLC)SystemControlComputer

Machine

OperatingMode

ProcessLibrary

UserLog

Display

Communication

Status

Page 17: Alcatel DRIE Operation Manual - University of …research.engineering.ucdavis.edu/.../2013/08/AlcatelDRIE.pdf1 of 1 Alcatel 601E DRIE (Deep Reactive Ion Etcher) Operation Manual Description:

17of17

ProcessStatusScreen:

1. PumpingStatusField.TrianglesshouldremainGreenindicatingpumpsareonduringprocesssteps.

2. Elementarymoves.RedindicatestheRobothascompletedthesubstratemovementindicatedbythetext

3. ProcessStatusField.YellowTriangleindicatesactivesystemcontroltomatchRecipestepvalues

4. ThermalizationStatusField.YellowTriangleindicatesactivesystemcontroltomatchRecipeSetpoints.ThermalizationSetpointsremainactiveafterstepiscompleteuntilfinishofprocessrecipe.

5. TemporizationStatusField.RedTriangleindicatesthestepDuration(timerhascompleted).

PumpingStatusElementaryMovesStatus

ProcessStatusField

TemporizationStatusField

ThermalizationStatusField

Page 18: Alcatel DRIE Operation Manual - University of …research.engineering.ucdavis.edu/.../2013/08/AlcatelDRIE.pdf1 of 1 Alcatel 601E DRIE (Deep Reactive Ion Etcher) Operation Manual Description:

18of18

6. ProcessPressure.TurquoiseFieldindicatessensorvalue.ThispressureisaresultoftheVATvalvepositionandtheamountofgasflowingintotheprocesschamber.ExpecttoseevaryingvaluesduringtheBoschEtchProcess.

7. RecipeGasFlowSetpointsaredisplayedinYellowfields.8. GasFlowSensorDisplaysareTurquoise.9. RFreflectedpowerdisplay.Boschprocesschangesvariablesfasterthansystem

canrespond.Varyinglevelsarenormal.10. SubstrateVoltage.ThisvoltagevarieswithSubstrate,RFpower,Chamber

pressureandGas

ProcessPressure

RecipeGasFlowSetpoints

GasFlowSensorDisplay

SubstrateVoltage

RFreflectedpowers

Page 19: Alcatel DRIE Operation Manual - University of …research.engineering.ucdavis.edu/.../2013/08/AlcatelDRIE.pdf1 of 1 Alcatel 601E DRIE (Deep Reactive Ion Etcher) Operation Manual Description:

19of19

11. StopProcessbutton.Abortsallprocessstepsthenremoveswaferimmediatelyfromthechamber

12. Step.HaltsstepinprogressandstartsnextstepintheRecipe.13. Step(resume).ResumesastopduetoanAlarm.Resumesastepthatwasbeing

held.14. Step(hold).TherecipeprocesstimeorDurationSetpointisignored.Thesystem

willcontinueruntheactivestepwithnoregardtotimeelapsed.Becarefulifthisbuttonispushedduringaprocessstepdon’tleavesystemunattended,itwillcontinuetoetch.

Step

(hold)

Step

(resume)

StepStop

Process