anesthesia system

6
CW Healthcare  Anesthesia Syste m 3  Anesthesia System & Ve ntilator Specialist

Upload: youssry-elsayed-mohamed

Post on 03-Jun-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

8/12/2019 Anesthesia System

http://slidepdf.com/reader/full/anesthesia-system 1/6

CW Healthcare

 Anesthesia System 3 Anesthesia System & Ventilator Specialist

8/12/2019 Anesthesia System

http://slidepdf.com/reader/full/anesthesia-system 2/6

 CW always insists the policy

of highest quality, best service and regards

the patients ‘health as our mission.

We sell the products abroad far to Asia,

 Africa, South America, Middle East,

where we have great reputation with you.

CW cares for best product,

best quality, best service

8/12/2019 Anesthesia System

http://slidepdf.com/reader/full/anesthesia-system 3/6

Selectatec Interlock Vaporizer

Integrated Breathing System IBS)

8/12/2019 Anesthesia System

http://slidepdf.com/reader/full/anesthesia-system 4/6

 

CWM-301D

Main Feature: 

  Applied for closed, semi-closed, semi-open inhalation anesthesia, controlled or assisted

ventilation, monitoring and displaying patients’ ventilation parameters

  Applied for adults and children

  Integrated anesthetic ventilation system, APL security air relief valve is available

 Vaporizer (anesthetic system transporting unit) meets the standard of ISO 8835-4 with

concentration precisely controlled. Advanced temperature, flow and pressure

compensation technology. Isoflurane, Enflurane, and Sevoflurane up to your option

 10.4’ TFT-LCD display screen

 Gas driven and electrical control, Lung compliance compensation function

Main Specification:

 Power : AC 220V±10%,50Hz±2%, built-in dc-battery for back-up(optional)

 Gas: O2, N2O, air

 Oxygen flush: 25~75L/min 

 Ventilation mode: IPPV, SIPPV, SIGH, SIMV, PSV, PEEP, Manual, Stand-by

 Monitoring parameters: Tidal Volume, Minute Ventilation, Breathing Rate, Airway Pressure,

O2 Concentration (optional), Lung compliance, PET CO2 etc.

 Waveform display: Pressure-time, flow velocity-time, pressure-volume, volume-time

  Alarm: Optimal third-class alarm unit, VT beyond limitation, upper and lower limitation of

ventilation, upper and lower limitation of airway pressure, asphyxiation, current failure,

gas source hypotony, gas circuit abnormity, upper and lower limitation of CO2

concentration etc

 Prompt and Protection: Prompt for parameter limitations, protection for unreasonable

parameter setting

CWM-302

  Applied for closed, semi-closed, semi-open inhalation anesthesia, controlled or assisted

ventilation, monitoring and displaying patients’ ventilation parameters

  Applied for adults and children

  Integrated anesthetic ventilation system, APL security air relief valve is available

 Vaporizer (anesthetic system transporting unit) meets the standard of ISO 8835-4 with

concentration precisely controlled. Advanced temperature, flow and pressure

compensation technology. Isoflurane, Enflurane, and Sevoflurane up to your option

 8.4’ TFT-LCD display screen

 Gas driven and electrical control, Lung compliance compensation function

Main Specification:

 Power : AC 220V±10%,

50Hz±2%, built-in dc-battery for back-up(optional) Gas: O2, N2O, air

 Oxygen flush: 25~75L/min 

 Ventilation mode: IPPV, SIPPV, SIGH, SIMV, Manual

 Monitoring parameters: Tidal Volume, Minute Ventilation, Breathing Rate, Airway

Pressure, O2 Concentration (optional), Lung compliance

 Waveform display: Pressure-time, flow velocity-time, pressure-volume,

volume-time(optional)

  Alarm: Optimal third-class alarm unit, VT beyond limitation, upper and lower limitation of

ventilation, upper and lower limitation of airway pressure, asphyxiation, current failure,

gas source hypotony, gas circuit abnormity, upper and lower limitation of CO2

concentration etc

 Prompt and Protection: Prompt for parameter limitations, protection for unreasonable

parameter setting

8/12/2019 Anesthesia System

http://slidepdf.com/reader/full/anesthesia-system 5/6

 

CWM-301

Main Feature:

  Applied for closed, semi-closed, semi-open inhalation anesthesia, controlled or assisted

ventilation, monitoring and displaying patients’ ventilation parameters

  Applied for adults and children

  Integrated anesthetic ventilation system, APL security air relief valve is available

 Vaporizer (anesthetic system transporting unit) meets the standard of ISO 8835-4 with

concentration precisely controlled. Advanced temperature, flow and pressure

compensation technology. Isoflurane, Enflurane, and Sevoflurane up to your option

 8.4’ TFT-LCD display screen

 Gas driven and electrical control, Lung compliance compensation function

Main Specification:

 Power : AC 220V±10%,50Hz±2%, built-in dc-battery for back-up(optional)

 Gas: O2, N2O, air

 Oxygen flush: 25~75L/min 

 Ventilation mode: IPPV, SIPPV, SIGH, SIMV, Manual

 Monitoring parameters: Tidal Volume, Minute Ventilation, Breathing Rate, Airway Pressure,

O2 Concentration (optional)

 Waveform display: Pressure-time, flow velocity-time, pressure-volume,

volume-time(optional)

  Alarm: Optimal third-class alarm unit, VT beyond limitation, upper and lower limitation of

ventilation, upper and lower limitation of airway pressure, asphyxiation, current failure,

gas source hypotony, gas circuit abnormity, upper and lower limitation of CO2

concentration etc

CWM-301C

Main Feature: 

  Applied for closed, semi-closed, semi-open inhalation anesthesia, controlled or assisted

ventilation, monitoring and displaying patients’ ventilation parameters

  Applied for adults and children

  Integrated anesthetic ventilation system, APL security air relief valve is available

 Vaporizer (anesthetic system transporting unit) meets the standard of ISO 8835-4 with

concentration precisely controlled. Advanced temperature, flow and pressure

compensation technology. Isoflurane, Enflurane, and Sevoflurane up to your option

 7’ TFT-LCD display screen

 Gas driven and electrical control, Lung compliance compensation function

Main Specification:

 Power : AC 220V±10%,50Hz±2%, built-in dc-battery for back-up(optional)

 Gas: O2, N2O, air

 Oxygen flush: 25~75L/min 

 Ventilation mode: IPPV, SIPPV, SIGH, SIMV, Manual

 Monitoring parameters: Tidal Volume, Minute Ventilation, Breathing Rate, Airway Pressure

 Waveform display: Pressure-time, flow velocity-time, pressure-volume,

volume-time(optional)

  Alarm: Optimal third-class alarm unit, VT beyond limitation, upper and lower limitation of

ventilation, upper and lower limitation of airway pressure, asphyxiation, current failure,

gas source hypotony, gas circuit abnormity, upper and lower limitation of CO2

concentration etc

8/12/2019 Anesthesia System

http://slidepdf.com/reader/full/anesthesia-system 6/6

 

SHENZHEN CHENWEI ELECTRONIC CO., LTD

Sales Centre: 93 Shengtai West Road, Jiangning Development Zone

Tel: +86 25 86989898 Fax: +86 25 57918628

www.chenwei-med.com

Email: [email protected], [email protected]

Best Product

Best Quality

Best Service

……

 

We insist!