bkn230_24

Upload: benny-tran

Post on 06-Jul-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/17/2019 bkn230_24

    1/2

    Monitoring of motorized fireand smoke dampers in combi-nation with the Communicationand Control Units BKS24-1Bor BKS24-9A 

    Mode of operation

    The BKN230-24 also functions as a dis-tribution power unit for supplying theBF..24..-ST, BLF24(-T)-ST spring-returnactuators that is connected to it. Another of its functions is to signal theNORMAL and SAFE positions of the dam-per (from the switches in the spring-returnactuators) to the central control panel overa 2-wire conductor. The same conductoris used for transmitting the ON/OFF con-trol command from the control panel tothe damper actuator via the BKN230-24.

    Installation and connections

    To simplify installation and connection,the spring-return actuator is fitted withconnectors which plug directly into theBKN230-24 unit.The 2-wire conductor is connected to theterminals 6 and 7. The terminals 1 and 2are for the direct connection of thermaltrips or smoke detectors.

    Functional testingIf it is proposed to test the actuator with-out the BKS24... unit connected, it can beswitched to NORMAL mode by fitting a

     jumper between terminals 3 and 4.The green LED in the BKN230-24 unit isbright when power (AC 24 V) is availableat the actuator.The SAFE damper position can bechecked either by pressing the push-button on the BAE72-S unit or by inter-rupting the power supply.

    Product features

    Plug-in connections.

    Power supply to damper actuators viaplug-in contact (AC 24 V from safety iso-lating transformer).

    Schematic diagrams see over.

    Communication and Power Supply Unit BKN230-24

    Dimensions

    BKN230-241

    2

    3

    4

    5

    67

    a

    b

    1)

    1) Jumper factory-fitted. Can be removed if necessary to be replaced by a thermoelectric trip.

    (The safety function will be triggered if terminals 1 and 2 are not linked).

    2) Jumper only used for commissioning purposes and without BKS24-... !

    2)

    M

    Power supply AC 230 V

    2-wire conductorto BKS24-...

    BAE72-S

    BLF24-ST, BLF24-T-STBF(G)24-T-ST, BF..24-ST

    Wiring diagram

    Connection• Power supply Cable 0.9 m with Euro-plug type 26• Actuator Plug 6 poles, plug 3 poles• Screw terminals for wire 2 × 1.5 mm2

    Power consumption 3.5 W (NORMAL position)

    For wire sizing 11 VA (incl. spring-return actuator)

    Nominal voltage AC 230 V 50/60 Hz

    Nominal voltage range AC 198…264 V

    Technical data BKN230-24

    Maintenance maintenance free

     Ambient temperature range – 20... + 50 °CNon-operating temperature – 40...+ 80 °CHumidity test to EN 60335-1

    EMC CE according to 89/336/EEC, 92/31/EEC, 93/68/EECLow Voltage Directive CE according to 73/23/EEC

    Protection class   II (all insulated)

    Weight 550 g

        p     0     0     3     8     2     1     0

        w     0     5     7     4     2     1     0

            4  .

            5

    130

    140

    153

            4        5

            4        3

            8        8

            5

            5        4

         d     0     0     2     5     7     0     7

    B C

  • 8/17/2019 bkn230_24

    2/2

    Connection and indication/Schematic diagrams (Examples)

    2-wire conductore.g. 2 x ø 0,6 mmdia.

    Control panel

       A   C   2   3   0   V

       P   /   N   /   E

    BKN230-24

    3 4 51 2 6 7

    M

    Spring-return actuator (24 V)

    a b

    Fire damper

       C

       o   n   t   r   o   l

       O

       N   /   O   F   F

       R   E   S   E   T

       T   E   S   T

         T      ~ AC 24 V 

     AC 24 V 

    BKS24-1B

    6438

       F   A   U   L   T

       D   a   m   p   e   r   p   o   s   i   t   i   o   n

       N   O   R   M   A   L

    11 9 15 10 2

    7

       D   a   m   p   e   r   p   o   s   i   t   i   o   n

       S   A   F   E

    BAE72-S

    2-wire conductore.g. 2 x ø 0,6 mmdia.

    Spring-return actuator (24 V)

    Spring-return actuator (24 V)

       A   C    2

       3   0   V

       P

       /   N    /

       E

       F   a  u   l   t

       c   o   n   t   a

       c   t   K   1

       A  u  x   i   l   i   a   r  y

       c   o   n   t   a

       c   t   K   2

              ~

     AC 24 V

    BKN230-24

    3 4 51 2 6 7

    M

    2-wire conductore.g. 2 x ø 0,6 mmdia.

    BKN230-24

    3 4 51 2 6 7

    a b

    a b

       P   r   o   g   r

       a   m   m   i   n   g

       i   n   p  u   t

       C   o   n   t   r   o   l

       O   N   /   O   F   F

    Fire damper 3

    Fire damper 1

    M

    Control panel

    BAE72-S

    BAE72-S

    BKS24-9A 

    18171615

    1 2 3 4 5 6 7 8 9 10

    14131211

              ~ AC 24 V

    a1............................................a9 b1...b9Input (dampers 1 and 3) (Common input)

    PROG

    TEST

    1

    2

    3

    4

    5

    6

    7

    8

    9

    FAULT (dampers 1 and 3)

    ➀ Connection: power supply AC 230 V

    ➁ Plug-in contacts for Belimo actuator 24 V

    ➂ Screw terminals, 7 poles

    ➃ Cable inputs for Belimo actuator

    ➄ Cable input for 2-wire conductor

    ➅ Transparent protection cover

    ➆ LED-indication, green (AC 24 V motor)

       b   0   1   0   7   2   1   0

      w   0   5   7   6   8   0   8

      w   0   5   7   8   2   1   0

       E   N   G  -   9   3   0   0   1  -   9   3   3   3   3  -   1   0

     .   0   2  -   5   0   0    •   P  r   i  n   t  e   d   i  n   S  w   i   t  z  e  r   l  a  n   d    •   Z   S   D

        •   S  u   b   j  e  c

       t   t  o   t  e  c   h  n   i  c  a   l  c   h  a  n  g  e  s

    B C