1 korea gtr no.7 2 nd phase research results dec. 8, 2009 ministry of land, transport and maritime...
TRANSCRIPT
1
KOREA GTR No.7 2nd Phase Research Results
Dec. 8, 2009
Ministry of Land, Transport and Maritime Affairs, Ministry of Land, Transport and Maritime Affairs,
Korea Automobile Testing and Research InstituteKorea Automobile Testing and Research Institute
GTR7-01-07
2
Actively research & Coop.Actively research & Coop.Actively research & Coop.Actively research & Coop.
KOREA
Backgrounds - regulatory
호 주
USAFMVSS
ECERegulations
SafetyStandards
KOREASafety
Standards
CANADACMVSS
EuropAsia
NorthAmerica
1998 협정
(GTR)Global
TechnicalRegulations
JAPANSafety
Standards
EECDirectives
Headrest. KMVSS upgrade plan During GTR 7 discussion, KOREA considered
harmonization with lead time, etc.
All possible GTR options will be considered on KMVSS.
Phase I GTR will be adopted as KMVSS in 2010.Before GTR introduce in KMVSS,
make the program (gov)
Adopting in KNCAPAdopting in KNCAP &&Lead Good H/R Performance Lead Good H/R Performance
Offer the advantage of design preceding, etc.Offer the advantage of design preceding, etc.
Static Dynamic
+
GTR No.7 Publish
(2008.3)
KNCAP
KMVSS Discuss with MLTM
GTR2nd Phase start
20052005 년 년 // 2006// 2006 년년 -2007-2007 년 년 // 2008// 2008 년 년 // 2009// 2009 년년 20052005 년 년 // 2006// 2006 년년 -2007-2007 년 년 // 2008// 2008 년 년 // 2009// 2009 년년
3
Objective of KOREA Research
GTR 2nd Phase Terms of reference
Head restraint Height
Whiplash Injury (MAIS1 or MAIS 2 more)
Define Test procedures
- Test condition
- Clarify the mechanism of whiplash injury
- Evaluation of BioRIDII
- Evaluation of Indicator
- Feasibility studies etc.
Objective
Harmonization of GTR No. 7 in KMVSS
Global cooperation for Head restraints
GTR Phase II
Work Scop
GTR No.7 Phase II
- Head restraints height : Effective height
in KOREA
- Dynamic Test
• Evaluation of BioRIDII : Repeatability,
Reproducibility
• Evaluation injury indicator in BioRIDII
• Check the BioRIDII calibration procedures
GTR
4
Stage 2(2009)
Head Restraints Height
Harmonization GTR No.7Harmonization GTR No.7
GTR No.7 Phase IIGTR No.7 Phase II
BioRID II
Discuss with MLTMGTR No.7 Review
Statistic review & Test Additional Test
Repeatability Test
BioRID II propriety review
Stage 1(2008)
Reproducibility TestGTR No. 7 2nd Amendment
Over all Research Schedule
New Cal. system Test
2010 will be published
.
5
Evaluation of BioRIDII performance
Test Condition Dummy & Number of tests
- Denton 3 different BioRIDII-g (S1, S3, S4)[ Dummy was calibrated before the test.]
- 3 times Test in KATRI(engineer also KATRI persons)
Pulse : KNCAP (Same as the E-NCAP Medium pulse 16km/h)
Seat & Head restraints setting : KNAP(Same as the the E-NCAP )
Neck injury indicator :
- Head X acc, Nkm, NIC, HRC, T1 X acc, Upper-Fx –Fz -My, Lower-Fx, -Fz,- My
Location Target measure Tolerance
H-point (X-axis) +20mm Forward ±10mm
H-point (Z-axis) 0mm ±10mm
Pelvis angle 26.5° ±2.5°
Head plane angle 0° ±1°
Backset 15mm Forward ±5mm
[ BioRID Setup Summary ][ Seld Pulse ]
6
Evaluation of BioRIDII
Method of Evaluation
Repeatability C.V = 100 (%) XX
Sd
X = Mean value of each dummy
Sd = Standard deviation of each dummy
S B
X
S
X G
Reproducibility C.V = 100 (%)
SB = n
1/2MSB-MSW XG = Mean value of 3 dummies
MSB : Mean square between groups (dummies) MSW : Mean square in a group (each dummy) n : Number of repetitions of test
7
Evaluation of BioRIDII
Seat condition & Dummy setting
SgRP to 머리지지대 최상단 높이- SAMPLE NO.1 : 840 ±10- SAMPLE NO.2 : 840 ±10- SAMPLE NO.3 : 850 ±10- SAMPLE NO.4 : 800 ±10
ⓐ
ⓑ
ⓔ
ⓒ
ⓓ
Measurement C.V
HRMD Measurement
S1S3S4
S1S3S4
S1S3S4
8
Evaluation of BioRIDII
Results of Repeatability Evaluation
C.
V .
Head X repeatability in all dummy is good. Among 3 dummies, each C.V. does not show
consistency but graphs are pretty similar. Even though BioRID calibrated, repeatable variation
has been depend on dummy.
9
Evaluation of BioRIDII
Results of Reproducibility Evaluation
Upper Fx & My, Lower Fz, Nkm_Nfa
are not acceptable indicators during the test.
Nkm_fa
ESV paper by Japan(09-0302)ESV paper (09-0492)
10
Evaluation of BioRIDII – Test site variation
Test Condition Dummy : BioRIDII-g 1 test each site.
Test Site : 2 different site (Hyundai, Dymos)
Pulse : KNCAP (Same as the E-NCAP Medium pulse 16km/h)
Seat : same seat, other conditions same repeatability test
11
Head X HRC T1 Acc
Upper Fx Upper Fz:
about 100N
Upper My :
about 7 Nm
Evaluation of BioRIDII – Test site variation
12
Purpose
- Neck Injury indicators analysis comparing
800 & 850mm H/R height Test condition
- Pulse : K-NCAP
(E-NCAP medium pulse)
- Seat setting : K-NCAP
- Dummy : Denon BioRID Iig (KATRI)
- Head restraint height : 800, 850mmHeadrest. height 800mm Headrest. height 850mm
Head Restraint Height – Non Active Seat Review of KOREA Anthropometry statistics,
the reasonable height of Head Restraint is 800mm
0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.2
000000000000TI00 [s]
-5
-2.5
0
2.5
5
7.5
10
12.5
Acc
(g)
T1 SPINE ACC X-AVERAGE_CFC_60_800mm
T1 SPINE ACC X-AVERAGE_CFC_60_850mm
H/R Height 800mm & 850mm
Data DescriptionTest No.:
Mode: BARRIER, NOT DEFINED
Test Velocity: [KPH]
Test Date:
Vehicle Code :
Pulse_ID:
Occupant InformationDummy Type : H3 AM50
Channel InformationS0VEHCMIAV00ACXG
Unit: g
Filter : CFC_60
Max. 10.27 g at 27 ms
Min. -1.19 g at 103 ms
# Velocity(kph)
Max. 15.54 KPH at 88 ms
T1 ACC
# Acceleration
0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.2
000000000000TI00 [s]
-200
0
200
400
600
800
1000
N
UPPER NECK FZ-CFC_1000_800mm
UPPER NECK FZ-CFC_1000_850mm
UPPER NECK FZ-CFC_1000_800mm
UPPER NECK FZ-CFC_1000_850mm
UPPER NECK FZ-CFC_1000_800mm
UPPER NECK FZ-CFC_1000_850mm
H/R Height 800mm & 850mm
Data DescriptionTest No.:
Mode: BARRIER, NOT DEFINED
Test Velocity: [KPH]
Test Date:
Vehicle Code :
Pulse_ID:
Occupant InformationDummy Type : H3 AM50
Channel InformationS0VEHCMIAV00ACXG
Unit: g
Filter : CFC_60
Max. 10.27 g at 27 ms
Min. -1.19 g at 103 ms
# Velocity(kph)
Max. 15.54 KPH at 88 ms
Fz
# Acceleration
0 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 0.09 0.1 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.2
000000000000TI00 [s]
-40
-30
-20
-10
0
10
20
30
NIC_800mm
NIC_850mm
H/R Height 800mm & 850mm
Data DescriptionTest No.:
Mode: BARRIER, NOT DEFINED
Test Velocity: [KPH]
Test Date:
Vehicle Code :
Pulse_ID:
Occupant InformationDummy Type : H3 AM50
Channel InformationS0VEHCMIAV00ACXG
Unit: g
Filter : CFC_60
Max. 10.27 g at 27 ms
Min. -1.19 g at 103 ms
# Velocity(kph)
Max. 15.54 KPH at 88 ms
NIC
# Acceleration
T1 Acc av Upper Fz NIC
Indicators on 800mm height H/R are slightly higher than 850mm height H/R But not a big different.
13
Evaluation of BioRIDII Calibration procedures
Current Version New Version : Changed part
Changed Parts : Head Rest Jig, Foam block, Probe, Sliding guild.
Evaluation
Repeatability Test : Graphs review
Dummy : 4 ea Denton BioRIDII-g
Test condition : Each dummy passed the current cal procedures and then
3 or 4 tests of each dummy were conducted on the new cal. system with H/R & not.
14
New sled without H/R Jig Cal. Result Graphs
Each dummy shows repeatable but there are some discrepancy with dummies.
New Sled Old SledNew Sled Old Sled
15
New sled wit H/R Jig Cal. Result Graphs
Each dummy shows repeatable but there are some discrepancy with dummies.
(Upper Neck Fx, My, Lower Neck Fx, Fz, My)
16
Other Issue
Pendulum force on new sled system is much higher then old version, so head & neck movement is too
strong and too much. It’s cause of neck bumper separation during the calibration test.
During the cal. test setup, sled keep moving, need fixing jig.
17
Evaluation of BioRIDII – Denton & FTSS
Test Condition Dummy : BioRIDII-g Denton & BioRIDII FTSS.
Test Site : KATRI, Test setup : same condition (repeatability test condition)
Test number : 3 times
Before
After
18
Evaluation of BioRIDII – Denton & FTSS
Head X T1 Acc
Upper Fx
Upper Fz
Upper My Lower My
Head X repeatability in two dummies are good.
Upper Fx is not acceptable with two dummies
Upper Fz & My & Lower My in Denton BioRID and
Upper Fz in FTSS BioRID is not acceptable for
repeatability analysis.
C.
V .
19
Summary
Result data for neck injury indicators on BioRIDII
- Repeatability : S1 & S3 dummy is marginable but S4 dummy is not acceptable.
- Reproducibility : Not acceptable for Upper Fx, Upper My, Lower Fz, & Nkm.
Similar results submitted last ESV. (Japan & Europe)
- Results of different site test are similar except upper Fz & My.
With repeatability & reproducibility issues, we may suggest some robust indicator after
full consideration for neck injury mechanism in stead of neck injury indicator.
→ In terms of the regulation, small variation of seat condition must be acceptable.
(Seat is not rigid structure)
Neck injury indicators on 800mm HR were slightly higher than 850m HR but not a big
different each other.
New cal. system shows good repeatable but the results between dummies are
different. (Need further study)
Neck injury indicators on Denton & FTSS BioRIDII are similar with each other.