1characteristics_setitv4

Upload: socaciu-viorica

Post on 14-Apr-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/30/2019 1Characteristics_setITV4

    1/12

    * Performance of series5

    2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc 17.12.2009

    Character i s t i c sne t - l i ne subs ta t i on au tomat i on

    Version: setIT V 4.004 17.12.09

    The integrated configuration tool setIT was extended with afully graphical dialogue for the assembly of components. Thisfunction allows an even faster integration of substationautomation and telecontrol. It also eases the handling andgives you an quick overview of the systems assembly.

    Achieving aims fasterAchieving aims fasterAchieving aims fasterAchieving aims faster

    Furthermore setITV4.004 brings extended functionality such as:

    Selective linkage to protective equipment

    Processing of archives with variable memory depth

    Optimised GPRS communication

    Integration of the newest series5 devices

    High-Speed-Download*

    Configuration via USB-Stick*

    up to 2 GB of archive memory*Diagnosis via Web-Server*

  • 7/30/2019 1Characteristics_setITV4

    2/12

    * Performance of series5

    2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.docSubject to modification17.12.2009

    Release noteRelease noteRelease noteRelease note ---- Differences to V 3.0Differences to V 3.0Differences to V 3.0Differences to V 3.0

    Graphical user interface for configuration of all base systems

    visual assembly of serial interfaces and I/Os

    Selective coupling of protective equipment

    Preprocessing of process data in the process image

    Merging addresses of protective equipment into address room and structure of control centre

    Processing of archives with variable memory depth

    modified memory management with automatic or manual partition

    Optimised GPRS communication

    IEC 60870-5-104 for VPN-Tunnel with GPRS

    Integration of ENET-2 card for optimised TCP/IP timing at GPRS

    Optimisation of the symmetric IEC 60870-5-101 driver for GPRS

    Complete integration of autarky compact systems and data logger aucolog into telecontrolwith IEC 60870-5-101/-104 protocol

    Negative confirmation of commands and desired values with time tag, in the case that therespective time spans have been exceeded.

    Validation of set points at coupling of external devices can be activated via status word

    Adjustment of idle condition for single-point information and commands

    Step position information with validity detection 8 bit or 32 bit

    Logging of process data in telecontrol report

    Remote diagnose with an external front-end station via switched telephone line, LAN or fieldinterface with IEC -101/-104 protocol or directly via switched telephone line or LAN with PUprotocol UNIP

    Integration of series5

    net-lineFW-5-BT net-line FW-5-BT with extension cards

    net-line FW-50-4 in

    housing BGT-S

    net-line FW-50

    e.g. pure router in BGT-M

    net-line FW-50-14 in housing BGT-L

  • 7/30/2019 1Characteristics_setITV4

    3/12

    * Performance of series5

    2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc, Subject to modification 17.12.2009

    Further functions for series5 systemsFurther functions for series5 systemsFurther functions for series5 systemsFurther functions for series5 systems****::::

    High-speed-download

    USBdownload and diagnosevia USB interface

    FTPdownload and diagnose via Ethernet LAN

    httpStations update via Web page

    Hand over of configuration with USB memory stick

    Saving operating system, firmware and configuration on USB memory stick

    Batch control

    Job processing of stick information for each station according to adjustment in setITRead out of status after update

    Archive read out over web page and USB memory stick

    Dynamic creation of web pages for web server in line with the configuration of process data

    Integration of several IEC 60870-5-104 substations over one interface at the master stationPartyline

    Support of fast information input < 1 ms with 16IE-5 card by dint of interrupt processing withminimised latencies

    Quick LAN connection due to copper or fibre optic switchesSWI1-1: 4* Tx or SWI1-2: Fx + 2 * Tx

    Cascading of racks via Ethernet with integrated switch

    New rack sizes for larger capacityBGT-S for up to 4, BGT-M for up to 7 and BGT-L for up to 14 I/O cards

    Up to 9 communication components4 serial, 2 switch- and max. 3 fieldbus components

    NTP-Protocol for time synchronisation according to IEC 61850

    Platform for integration of IEC 61850 coupling of protective equipment

  • 7/30/2019 1Characteristics_setITV4

    4/12

    * Performance of series5

    2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc, Subject to modification 17.12.2009

    General informationGeneral informationGeneral informationGeneral information

    Open & standard communication for

    New installation as system solution or component

    Extension usually in the field of power system control and industry

    Integration of protective equipment via -103 or external components with fieldbus

    Quick and easy configuration with setIT

    Very fast realisation of your project due to easy handlingMenu, context menus, mouse- and hotkey functions

    Learning the ropes quickly be dint of tree structures and well established handling processesfrom the MS Office world (copy/paste, do/undo)

    Avoiding faulty entries with dynamic menus and context sensitive entry masks onlyonlyoperative components, options and combinations are selectable

    Hand over of mutual configurationssingle-point-of-entry

    High flexibility in terms of topologythe telecontrol network is adjustable to almost every existingstructure

    Fast modification and extension of installationsTypes of interfaces, protocols, station types

    Future proof with modern platform and hardware

    Windows based configuration tool with state of the art GUI

    setITsupport all characteristics of System-4 and series5 hardware

    FW-4, FW-40, FW-10-S4, BGT-4000, FW-5, FW-50 etc.Active advancements, maintenance and optimising

    Download and Upload from operating system, system software, configuration and add-on

    modules including version control

    Saving configuration in access data base

    Import and export of configuration with csv file for documentation or further editing with Excel

    Recording of system events

    Separately loadable system report

    Logging of process data changes in telecontrol report

    Reports separately loadable as csv-file

    Memory management and archive processing

    Processing of archives with variable memory depthmodified memory management with automatic or manual partition

    Quick ROI due to fair license system

    Free 30 days demo-version with optional extension.

    Single user license, multi user license and company license

  • 7/30/2019 1Characteristics_setITV4

    5/12

    * Performance of series5

    2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc, Subject to modification 17.12.2009

    CommunicationCommunicationCommunicationCommunication

    Communication according to standard protocols.

    IEC 60870-5-101 Serial coupling with dedicated line

    IEC 60870-5-102 Routing of data from remote meter reading

    IEC 60870-5-103 Coupling of protective equipment

    IEC 60870-5-104 Coupling with TCP-IP /LANSelective coupling of protective equipment via IEC 60870-5-103

    Preprocessing of process data in the process image

    Merging addresses of protective equipment into the address room and structure of the controlcentre

    Rapid coupling to control centreswith IEC 60870-5-10x protocols supporting ProCoS, PSI, STS/BTC, SAT, ids, ABB, repas ...

    OPC server supported

    Handover of station names, names of process points and parameter in namespace of OPC

    Supervision name semantic respectively automatic conversion with underliningsupport of redundant OPC-Server

    Free cross-connection in network

    free linkage of information inputs to the outputs of the network

    overall cross-connection by dint of control centre or router

    Structured station- and object addressing in up to 6 levels

    Switched telephone line & remote diagnostics via telephone line

    switchable login procedure name, password

    Translation form IEC 60870-5-101 to IEC 60870-5-104 by router

    On site integration of PLC functions with codeIT

    Optimised GPRS communication

    GPRS with VPN Tunnel directly over IEC 60870-5-104

    Optimisation of the symmetric IEC 60870-5-101 driver for GPRS

  • 7/30/2019 1Characteristics_setITV4

    6/12

    * Performance of series5

    2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc, Subject to modification 17.12.2009

    Integration & AdaptionIntegration & AdaptionIntegration & AdaptionIntegration & Adaption

    flexible types of communication are supported:

    direct coupling to control system point-to-point or LAN mode

    Star coupling point-to-point mode to router

    LAN Industrial Ethernet, TCP/IP, pulse code modulation

    Partyline Networks and loop lines multipointvariable structures in complex networks and cascading

    at subordinated networks routers are the connection to controlcentre or telecontrol knot

    Dial up connection via analogue link, ISDN or GSM

    with switchable protection against remote access

    Multiple link to control centres

    Filtering of data points with transmission lists for a selective transmission to control system

    Transformable address structures for a separate structure of the secondary control system

    Time synchronisation via DCF and GPS receiver

    Flexible fieldbus coupling and gateways for the implementation of external devices

    Profibus-DP master/slave

    Modbus RTU master/slave

    Modbus RTU master/slave

    MPI 3964R/RK512

    Free allocation of external devices/components

    external components are integrated as station objects

    process data are allocated with free declaration of LEDs

    process data of external devices are provided just like system-own process data

    Complete integration of autarky compact systems and data logger aucolog into telecontrolwith IEC 60870-5-101/-104 protocol

    Integration of autarky objects in interconnected systems

  • 7/30/2019 1Characteristics_setITV4

    7/12

    * Performance of series5

    2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc, Subject to modification 17.12.2009

    Additional functions in the section of interconnected systems andAdditional functions in the section of interconnected systems andAdditional functions in the section of interconnected systems andAdditional functions in the section of interconnected systems and

    subsubsubsubstation automationstation automationstation automationstation automation

    Command termination;via EVU special cards with 1 of n monitoring

    Single- and double commands 1,5 and 2 pole

    Adjustable for each command: post command lag time, suppression of imperfection, couplingresistance

    measuring circuit test from 10 to 20 k

    Cascading of several racks with IEC profileAdministration of of up to nine racks at only one station address

    1 of n monitoring of several racksAt cascaded systems large command groups can be assembled. The EVU-X cards loops the interlocksignals of the 1 of n monitoring to the implemented racks.

    Process image in telecontrol router

    Telecontrol router are able forward the data of subordinated stationsdefault value generation at control commandsControl commands can be set to an individual default status in the case of disturbed communicationor system start.

    Rapid acquisition of measurands (max. 1 kHz pulses)with the intelligent counter card CNT-1

    Logging of measurands with external pulse inputs at the deviceTime synchronised logging is available due to external control signals.

    Binary step position information, BCD and 32 bit

    Step position information can be directly linked with 32 bit.

    Intuit configuration with setIT

  • 7/30/2019 1Characteristics_setITV4

    8/12

    * Performance of series5

    2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc, Subject to modification 17.12.2009

    Cascaded stations for large capacities

  • 7/30/2019 1Characteristics_setITV4

    9/12

    * Performance of series5

    2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc, Subject to modification 17.12.2009

    SecuritySecuritySecuritySecurity

    Redundancy functions

    Support of redundant control centre

    Twinned master stations easily settablewatchdog monitors the functions of the master stations and autarky switches hot/standby mode

    Quick loop line over baseband modem or WT96 as daisy-chainSecurity at short-circuit, line interruption and station- or modem breakdown

    Redundancy of switched telephone linePreferred interface, alternative numbers, prioritisation

    System informationprovide station status and internal error messages as binary single-point information

    Combining system information to group indicationLogical linkage without PLC layer

    Cross-connection of system informationSystem information may be handed over as output information to any station

    System history logs all station internal processes

    Archiving of reports in the case of communication error

    Default value generation at outputs in the case of communication error

    Management of system- and configuration version

    Optical marker for new system- / configuration versions after generating

    Control of station and version access prior to download

    Twinned master stations in hot/standby operation

  • 7/30/2019 1Characteristics_setITV4

    10/12

    * Performance of series5

    2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc, Subject to modification 17.12.2009

    Support at diagnostics & project planningSupport at diagnostics & project planningSupport at diagnostics & project planningSupport at diagnostics & project planning

    Comprehensive diagnostics and help functions are already integrated

    Online help provides a complete manualcontext sensitive forwarding to information with F1, search function

    Indication of connection status

    of interconnected station and process data states scaled or in plain textQuick correction of configuration errors

    Link to entry masks during generating

    Extended diagnostics with integrated telegram analyser (optionally)

    Recording of data transmission and receiving in substation is possible without additional devices

    Trigger functionsStart/stop or marking of character strings

    Logging as csv- file in a revolving archive

    Memory management of csv-files

    HTML export for an easy transfer of the recording

    Chronometry and indication of receiving errors

    Online switching of view

    Data flow analysis

    Exchange and distribution of station's/router's data

    Follow up of the router's information paths

    Extended help at installation

    Analysis of coverage

    New value message

    Report for documentation printable or as pdf-file

    List for quick overview of prior indications

    Integrated interface monitor (optionally)

  • 7/30/2019 1Characteristics_setITV4

    11/12

    * Performance of series5

    2009 SAE IT-systems GmbH & Co. KG Characteristics_setITV4.doc, Subject to modification 17.12.2009

    Types of communicationTypes of communicationTypes of communicationTypes of communication

    Modes

    point-to-point

    Partyline

    Star operation

    Loop modeConcentrator connection & routing

    Transmission routes

    Dedicated lines

    LAN networks

    Dial-up links

    Radio communication networks (in development)

    GSM - Transmission

    GPRS if the provider complies with the requirements

    Cause of transmission

    Spontaneous atchanges or reaching limit values

    Cyclic

    queried by GA

    in background

    transmission of integrated totals inside the intervalspontaneously and synchronous, from 12 s to8 hours

    Integration and communication of telecontrol and substation automation to control centre

  • 7/30/2019 1Characteristics_setITV4

    12/12

    2009 SAE IT-systems GmbH & Co. KG Subject to modification 17.12.2009

    Supported types of process dataSupported types of process dataSupported types of process dataSupported types of process data

    Inputs

    Single-point information

    Single-point information

    Step position information 7/8/32 bit, binary, BCD

    Measured values 8/12/16/32 bit

    Integrated total inputs 16/32 bit

    System information

    Group indication with logical connection

    Cumulative values equally spaced interval values from 1 to 60min

    Checkback definition command termination with DSO card

    Outputs

    Single commands

    Double commands

    Regulating step command

    Set points 8/12/16/32 bit

    Integrated total outputs 16/32 bit

    Cross-connection & etc.

    Single point information in control direction

    Double information in control direction

    System information in control direction

    Measurand in command direction

    Integrated total cross-connection 16/32 bitInterval data, Interval-/ alarm-/ operation archive

    setIT's easy structure of and configuation