ZADACI ZA VJEŽBU 1. Trofaznom asinkronom motoru 400 V, 50 Hz, 2p=6 izmjeren je moment kod nazivnog
opterećenja Mn=163 Nm, a moment trenja i ventilacije iznosi 5 Nm. Kod nazivnog opterećenja motora i narinutih 380 V, 50 Hz ukupni gubici u statoru iznose 750 W, a frekvencija rotorskih struja f2=1,5 Hz. Izračunajte snagu motora na osovini i faktor korisnosti. Rješenje: P2 = 16,6 kW, η=90,5 %
2
1
1.5 0.0350
fsf
= = =
160 60 50 1000 r/min3s
fnp
⋅= = =
( ) ( )1 1000 1 0.03 970 r/minsn n s= − = − =
2 2 2970163 16.6 kW
30 30nP M M π πω= = = =
( ) ( ) ( )2 2 , 2 ,970163 5 17.1 kW
30 30tr v tr vnP M M M M π πω= + = + = + =
17.1 17.62 kW1 1 0.03
mehokr
PPs
= = =− −
1 1 17620 750 18370 Wokr gP P P= + = + =
2
1
1600 0.905 ili 90.5%18370
PP
η = = =
![Page 2: Auditorne_vjezbe_-_asinkroni](https://reader031.vdocuments.pub/reader031/viewer/2022020217/55204e7e497959892f8b4956/html5/thumbnails/2.jpg)
Elektromehaničke i električne pretvorbe energije ZADACI ZA VJEŽBU
2
2. Trofazni kolutni asinkroni 6-polni motor ima podatke: statorski i rotorski namot su spojeni u zvijezdu, otpor između kliznih koluta rotora u toplom stanju iznosi Rab = 0,265 Ω, a rasipna reaktancija faze rotorskog namota Xσ2 = 0,265 Ω. U slučaju priključenja statorskog namota na napon 400 V, 50 Hz, uz zakočen rotor, na otvorenim kliznim kolutima rotora izmjeren je napon 217 V. Motor je opterećen i vrti se brzinom 950 r/min. Ukupni statorski gubici iznose 2,2 kW, a gubici trenja i ventilacije su 1,2 kW. Frekvencija mreže je 50 Hz. Treba izračunati: a) klizanje s u %, b) frekvenciju rotorskih struja, c) iznos struje rotora, d) gubitke u namotu rotora, e) snagu okretnog polja, f) razvijeni elektromagnetski moment, g) razvijenu snagu na osovini, h) moment na osovini, i) snagu koju motor uzima iz mreže, j) korisnost motora η. Rješenje: a) s = 5 %, b) f2 = 2,5 Hz, c) I2 = 301,5 A, d) PCu2 = 4363,3 W, e) Pokr = 87266,2 W, f) Mem = 833,75 Nm, g) P2 = 81703 W, h) M2 = 821,27 Nm, i) P1 = 89466,2 W, j) η = 91 %
60 60 50 1000 r/min
3sfn
p⋅
= = =
a) 1000 950 0.05 ili 5%1000
s
s
n nsn− −
= = =
b) 2 1 0.05 50 2.5 Hzf sf= = ⋅ =
c) 202 2 2
2 222
217 301.5 A0.0163 3 0.2650.05
EIR Xs σ
= = =⎛ ⎞ ⎛ ⎞+ +⎜ ⎟ ⎜ ⎟⎝ ⎠ ⎝ ⎠
d) 2 22 2 23 3 301.5 0.016 4363.31 WCuP I R= = ⋅ =
e) 2 4363.31 87266.2 W0.05
Cuokr
PPs
= = =
f) 87266.2 3030 833.75 Nm1000
okr okrem
s s
P PMnω π π
⋅= = = =
g) 2 2 , 87266.2 4363.31 1200 81702.9 Wokr Cu tr vP P P P= − − = − − =
h) 2 22
81702.930 30 821.27 Nm950
P PMnω π π
= = = =
i) 1 1 87266.2 2200 89466.2 Wokr gP P P= + = + =
j) 2
1
81702.9 0.91 ili 91%89466.2
PP
η = = =
![Page 3: Auditorne_vjezbe_-_asinkroni](https://reader031.vdocuments.pub/reader031/viewer/2022020217/55204e7e497959892f8b4956/html5/thumbnails/3.jpg)
Elektromehaničke i električne pretvorbe energije ZADACI ZA VJEŽBU
3
3. Pokusom praznog hoda i kratkog spoja trofaznog asinkronog kaveznog motora 400 V, 50 Hz, 30 kW, spoj trokut, otpora faze statora u pogonski toplom stanju kod nazivnog opterećenja R1 = 0,47 Ω, dobiveni su sljedeći rezultati:
kratki spoj: 100 V, 70A , 6 kW prazni hod: 400 V, 20,8 A, 1,2 kW.
Na osnovi navedenih podataka odrediti parametre nadomjesne sheme za stacionarno stanje. Pretpostavite da je Xσ1 = X’σ2.
Rješenje: R0 = 451 Ω, Xm = 32,31 Ω, R1= 0,47 Ω, R’2 = 0,754 Ω, Xσ1 = X’σ2 = 1,075 Ω Kratki spoj:
1 2kR R R′= +
( )2 21 23 3k k k kP I R I R R′= = +
70 A3kI = - fazna struja
2 1 22
6000 0.47 0.754703 33
k
k
PR RI
′ = − = − = Ω⋅
100 2.474703
kk
k
UZI
= = = Ω
1 2 0.47 0.754 1.224kR R R′= + = + = Ω 2 2 2 22.474 1.224 2.15k k kX Z R= − = − = Ω
1 2 1.0752
kXX Xσ σ′= = = Ω
Prazni hod:
00
0
400 33.30920.83
UZI
= = = Ω - impedancija motora u praznom hodu
22
0 0 0 120.83 1200 3 0.47 996.7 W
3P P I R ⎛ ⎞′ = − = − ⋅ =⎜ ⎟
⎝ ⎠ - uži gubici praznog hoda (željezo +
mehanički gubici)
0 0 0 120.8400 1.075 387.09 V
3E U I Xσ− = − ⋅ = - približna vrijednost uz zanemarenje R1 i R0
2 2 20 0
0 00 0
31 3 387.09 451.03 996.7
E EP RR P
⋅′ = ⇒ = = = Ω′
00
0
387.09 0.858 A451.0r
EIR
= = = , 2
2 2 20
20.8 0.858 11.98 A3
I I Iμ μ⎛ ⎞= − = − =⎜ ⎟⎝ ⎠
0 387.09 32.3111.98m
EXIμ
= = = Ω
![Page 4: Auditorne_vjezbe_-_asinkroni](https://reader031.vdocuments.pub/reader031/viewer/2022020217/55204e7e497959892f8b4956/html5/thumbnails/4.jpg)
Elektromehaničke i električne pretvorbe energije ZADACI ZA VJEŽBU
4
4. Trofazni četveropolni asinkroni kavezni motor ima podatke: 400 V, 3,15 kW, 6,7 A, 50 Hz, 1384,5 r/min, η = 84 %. Parametri nadomjesne sheme su: R1=1,7 Ω, R’2 = 2,6 Ω, Xσ1 = 2,8 Ω, X’σ2 = 3,3 Ω, Xm = 96 Ω. Zanemarite otpor R0 u poprečnoj grani. Stator je spojen u zvijezdu. Treba izračunati: a) faktor snage cos ϕ, b) približni iznos struje praznog hoda, c) gubitke u rotoru PCu2, d) brzinu vrtnje pri nazivnom opterećenju uz pretpostavku da su gubici trenja i ventilacije
1 % nazivne snage, e) struju kratkog spoja pri nazivnom naponu, f) potezni moment pri nazivnom naponu. Rješenje: a) cos ϕ = 0,808, b) I0=-j2.337 A, c) PCu2=248.8 W, d) nn=1391,2 r/min, e) Ik = 30,96 A, c) Mk = 47,6 Nm
a) 2
1 1
3150cos 0.8083 3 400 6.7 0.84
PU I
ϕη
= = =⋅ ⋅ ⋅
b) ( ) ( )
10
1
400 2.337 A3 3 2.8 96m
UI j j jX Xσ
= − = − −+ +
c) 01 1 1cos sin 6.7 0.808 6.7 0.589 5.414 3.949 6.7 36.1 AI I jI j jϕ ϕ= − = ⋅ − ⋅ = − = −
( ) 02 1 0 5.414 3.949 2.337 5.414 1.612 5.648 16.6 AI I I j j j′ = − = − − − = − = −
2 22 2 23 3 5.648 2.6 248.8 WCuP I R′ ′= = ⋅ ⋅ =
d) 2 , 3.15 0.01 3.15 3.181 kWmeh tr vP P P= + = + ⋅ =
2 2
2
248.8 0.07253181 248.8
Cu Cun
okr meh Cu
P PsP P P
= = = =+ +
( ) ( )1 1500 1 0.0725 1391.2 r/minn s nn n s= − = − =
e) ( ) ( ) ( ) ( )2 2 2 21 2 1 2 1.7 2.6 2.8 3.3 7.46kZ R R X X′ ′= + + + = + + + = Ω - zanemarena
poprečna grana
11 2
400 30.96 A3 3 7.46k k
k
UI IZ
′= = = =⋅
f) 2
2 23 3 30.96 2.6 30 47.6 Nm1500
kk
s
I RMω π′ ′ ⋅ ⋅
= = =
![Page 5: Auditorne_vjezbe_-_asinkroni](https://reader031.vdocuments.pub/reader031/viewer/2022020217/55204e7e497959892f8b4956/html5/thumbnails/5.jpg)
Elektromehaničke i električne pretvorbe energije ZADACI ZA VJEŽBU
5
5. Na trofaznom asinkronom motoru 200 kW, 6 kV, 50 Hz, spoj zvijezda, 1480 r/min izvršen je pokus kratkog spoja sa sniženim naponom, jer nije bilo mogućnosti u ispitnom laboratoriju direktno izmjeriti potezni moment i struju kratkog spoja. Kod 1500 V, 50 Hz narinutih na stator struja je iznosila 30 A, a snaga uzeta iz mreže Pk = 22 kW. Otpor između stezaljki namota statora u toplom stanju iznosio je 3,225 Ω. Moment gubitaka zbog vlastitog trenja motora iznosi 27,5 Nm. Koliko bi iznosio približno potezni moment i struja kratkog spoja kod nazivnog napona, te koliki je odnos poteznog prema nazivnom momentu? Rješenje: Mkn = 1770 Nm, Ikn = 120 A, Mkn/Mn = 1,372
Bez obzira na spoj namota (trokut ili zvijezda), ako je poznat otpor između stezaljki namota Rst, vrijedi
21 1 1
32Cu stP I R=
Iz pokusa kratkog spoja slijedi 2 2
1 2 2 1 1 13 22000 1.5 30 3.225 17646 W2k Cu Cu Cu k Cu k k stP P P P P P P I R= + ⇒ = − = − = − ⋅ ⋅ =
2,
17646 30 112.3 Nm1500
Cuk tr v
s
PM Mω π
+ = = = pri Uk = 1500 V
112.3 27.5 84.8 NmkM = − = Uz zanemarenje utjecaja zasićenja na rasipnu reaktanciju vrijedi
600030 120 A1500
nkn k
k
UI IU
= = =
2 2600022 352 kW1500
nkn k
k
UP PU⎛ ⎞ ⎛ ⎞= = =⎜ ⎟ ⎜ ⎟
⎝ ⎠⎝ ⎠
2 22 1
3 352000 1.5 120 3.225 282340 W2Cu n kn kn stP P I R= − = − ⋅ =
2 2, ,
282340 30 27.5 1770 Nm1500
Cu n Cu nkn tr v kn tr v
s s
P PM M M Mω ω π
+ = ⇒ = − = − =
2 20000030 30 1290 Nm1480
nn
n
PMn π π
= = =
1770 1.3721290
kn
n
MM
= =
![Page 6: Auditorne_vjezbe_-_asinkroni](https://reader031.vdocuments.pub/reader031/viewer/2022020217/55204e7e497959892f8b4956/html5/thumbnails/6.jpg)
Elektromehaničke i električne pretvorbe energije ZADACI ZA VJEŽBU
6
6. Trofaznom kolutnom asinkronom motoru poznati su podaci: 1250 kW, 6000 V, 50 Hz, 1480 r/min, cos ϕ = 0,91, η = 0,96. Napon među kolutima rotora spojenog u zvijezdu iznosi 865 V u mirovanju. Maksimalni moment je 2,7 puta veći od nazivnog. Izračunajte: a) gubitke u bakru rotora kod nazivnog opterećenja, b) klizanje kod kojeg motor razvija maksimalni moment, c) struju rotora kod nazivnog opterećenja, d) struju statora kod nazivnog opterećenja. Zanemariti mehaničke gubitke i pad napona na impedanciji statora. Rješenje: PCu2=16892 W, b) spr=0.06944, c) I2n=845,6 A, d) I1n=137,7 A a) 2Cu n okrP s P=
1500 1480 0.01331500
s nn
s
n nsn− −
= = =
2
1 1meh n
okrn n
P PPs s
=− −
3
22
1250 100.0133 16892 W1 0.0133
nCu n
n
PP ss
⋅= = =
−
b) Klossova jednadžba u pojednostavljenom obliku
2 22 2 2 0pr pr prn npr n pr n
prnpr pr n n n
pr n
s M MM s s s s sssM s s M Ms s
= ⇒ + = ⇒ + − + =+
2 2
21,2 1pr pr pr pr
pr n n n nn n n n
M M M Ms s s s s
M M M M
⎛ ⎞⎛ ⎞ ⎛ ⎞⎜ ⎟= ± − = ± −⎜ ⎟ ⎜ ⎟⎜ ⎟⎝ ⎠ ⎝ ⎠⎝ ⎠
( ) 121,2
2
0.069440.0133 2.7 2.7 1
0.00256pr
pr
pr n
ss
s s
⎧ =⎪= ± − = ⎨= <⎪⎩
c) 22202 2 2
222
2
3 30 3 30okrn
s s s
n
P EI R RMn nR X
s σ
ω π π= = =
⎛ ⎞+⎜ ⎟
⎝ ⎠
202 2
222
n
EIR Xs σ
=⎛ ⎞
+⎜ ⎟⎝ ⎠
Za mala klizanja u okolici nazivnog momenta vrijedi 22
n
R Xs σ>> pa se može približno
pisati
2 2 2 2 220 20 20 20 202
2222 222
2
3 3 30 3 303 30 30 330
n n n n nn
ns s s n s ns
nn
E E s E s E s n E sRM R Pn R n n M n PR nX ns σ
π π π ππ
⋅ ⋅= ⇒ = = =
⎛ ⎞+⎜ ⎟
⎝ ⎠
![Page 7: Auditorne_vjezbe_-_asinkroni](https://reader031.vdocuments.pub/reader031/viewer/2022020217/55204e7e497959892f8b4956/html5/thumbnails/7.jpg)
Elektromehaničke i električne pretvorbe energije ZADACI ZA VJEŽBU
7
2
2 3
865 0.01331480 33 7.875 mΩ1500 1250 10
R
⎛ ⎞⎜ ⎟⎝ ⎠= =
⋅
22 2 2
22 2 2 2
222
3
3
33
1 3 11 1
1250 10 0.0133 845.6 A3 7.875 10 1 0.0133
Cu nokr
n n n n n nn
n n nmeh nokr
n n
P I RPs s I R P P sI
s s R sP PPs s
−
⎫= = ⎪
⎪⇒ = ⇒ =⎬ − −⎪=⎪− − ⎭
⋅= =
⋅ ⋅ −
ili
20 20
2 322
222
865 0.0133 845.6 A7.875 103n
n
E EI sRR X
s σ
−= = =⋅⎛ ⎞
+⎜ ⎟⎝ ⎠
d) 1 13 cosn n nP U I ϕ=
21
nn
PPη
=
3
21
1250 10 137.7 A3 cos 3 6000 0.91 0.96
nn
n
PIU ϕη
⋅= = =
⋅ ⋅ ⋅
![Page 8: Auditorne_vjezbe_-_asinkroni](https://reader031.vdocuments.pub/reader031/viewer/2022020217/55204e7e497959892f8b4956/html5/thumbnails/8.jpg)
Elektromehaničke i električne pretvorbe energije ZADACI ZA VJEŽBU
8
7. Centrifugalnu pumpu s karakteristikom momenta 2
0,95 0,05p n nn
nM M Mn
⎛ ⎞= +⎜ ⎟
⎝ ⎠ pokreće
trofazni kolutni asinkroni motor s podacima 8 kW, 380 V, 50 Hz, spoj zvijezda, 18 A, 1435 r/min i otpora po fazi rotora u toplom stanju R2 = 0,65 Ω. Nazivni moment i broj okretaja pumpe jednaki su odgovarajućim nazivnim vrijednostima motora. Odredite vrijednost otpora koji treba dodati po fazi rotora da bi se dobila brzina vrtnje agregata pumpa-motor 1200 r/min. Rješenje: Rdod = 3,56 Ω
Moment pumpe kod 1200 r/min
2 2
112000.95 0.05 0.95 0.05 0.7141435p n n n n n
n
nM M M M M Mn
⎛ ⎞ ⎛ ⎞= + = + =⎜ ⎟ ⎜ ⎟⎝ ⎠⎝ ⎠
1 1 0.714m p nM M M= =
112001 1 0.21500s
nsn
= − = − =
14351 1 0.04331500
nn
s
nsn
= − = − =
U području malih klizanja može se pretpostaviti da je momentna karakteristika motora linearna, tj. da vrijedi Mm/s = konst.
1 12
2
0.0433 0.714 0.0309m n mn
n n
M M Ms ss s M
= ⇒ = = ⋅ =
Iz uvjeta jednakih rotorskih struja za moment Mm1 kod klizanja s1 i s2 slijedi
20 20 2 2 12 22 2
1 2 22 22 2
2 21 2
1doddod
dod
E E R R R sI R Rs s sR R RX X
s sσ σ
⎛ ⎞+= = ⇒ = ⇒ = −⎜ ⎟
⎝ ⎠⎛ ⎞ ⎛ ⎞++ +⎜ ⎟ ⎜ ⎟
⎝ ⎠ ⎝ ⎠
2 20.2 1 5.47 5.47 0.65 3.56
0.0309dodR R R⎛ ⎞= − = = ⋅ = Ω⎜ ⎟⎝ ⎠
![Page 9: Auditorne_vjezbe_-_asinkroni](https://reader031.vdocuments.pub/reader031/viewer/2022020217/55204e7e497959892f8b4956/html5/thumbnails/9.jpg)
Elektromehaničke i električne pretvorbe energije ZADACI ZA VJEŽBU
9
8. Trofazni kolutni četveropolni asinkroni motor za 50 Hz radi u režimu protustrujnog kočenja s brzinom vrtnje 375 r/min i razvija kočni moment 295 Nm. Motor ima gubitke u bakru i željezu statora iznosa 5 kW. Zanemarite gubitke u željezu rotora i mehaničke gubitke. Izračunajte: a) snagu kočenja na osovini motora, b) snagu okretnog polja, c) snagu koju motor uzima iz mreže, d) gubitke u bakru rotora. Rješenje: a) P2 = -11,58 kW, b) Pokr = 46,34 kW, c) P1 = 51,34 kW, d) PRdod + Pcu2 = 57,92 kW
a) 2375295 11.58 kW
30 30nP M M π πω −⎛ ⎞= = = = −⎜ ⎟
⎝ ⎠
b) 3751 1 1.251500
s
s s
n n nsn n− −⎛ ⎞= = − = − =⎜ ⎟
⎝ ⎠
2 11.58 46.34 kW1 1 1 1.25
mehokr
P PPs s
= = − =− − −
c) 1 1 1 46.34 5 51.34 kWokr Cu FeP P P P= + + = + = d) 2 1.25 46.34 57.92 kW
dodR Cu okrP P sP+ = = ⋅ =
![Page 10: Auditorne_vjezbe_-_asinkroni](https://reader031.vdocuments.pub/reader031/viewer/2022020217/55204e7e497959892f8b4956/html5/thumbnails/10.jpg)
Elektromehaničke i električne pretvorbe energije ZADACI ZA VJEŽBU
10
9. Trofazni asinkroni motor 36 kW, 380 V, 50 Hz ima mehaničku karakteristiku koja je praktički linearna u području od s = 0 do s = spr (prekretno klizanje). Kod nazivnog opterećenja motor se vrti brzinom 970 r/min. Rotor je spojen u zvijezdu. Otpor između dva klizna koluta iznosi R2 = 0,11 Ω u pogonski toplom stanju. Motor spušta teret težine 1200 N koji visi na užetu namotanom na bubanj promjera 0,5 m. Koliko otpora treba uključiti u rotorski krug motora da bi motor spuštao teret protustrujnim kočenjem brzinom 3 m/s. Zanemarite pad napona na statorskoj impedanciji. Rješenje: Rdod = 2,36 Ω
2
30 60 60 3 114.6 r/min20.5
30
v vD D vn
Dn
ωωπ π ππω
⎫= = ⎪⎪⇒ = = = =⎬⎪
= ⎪⎭
Klizanje kod kočenja
114.61 1 1.11461000
sk
s s
n n nsn n− −⎛ ⎞= = − = − =⎜ ⎟
⎝ ⎠
2 3600030 30 354.4 Nm
970n
nn
PMn π π
= = =
9701 1 0.031000
nn
s
nsn
= − = − =
n0.51200 300 Nm=0.846M
2 2t tDM F= = =
0.03 0.846 0.0254t n tt n
t n n
M M Ms ss s M
= ⇒ = = ⋅ =
( )2 220 20 22
22 2
3 330 30 1t k dod kt dod
s dod s t k t
E s E s R R sRM R RR n R R n s s sπ π
⎛ ⎞+= ⇒ = ⇒ = −⎜ ⎟+ ⎝ ⎠
0.11 1.1146 1 2.362 0.0254dodR ⎛ ⎞= − = Ω⎜ ⎟
⎝ ⎠
![Page 11: Auditorne_vjezbe_-_asinkroni](https://reader031.vdocuments.pub/reader031/viewer/2022020217/55204e7e497959892f8b4956/html5/thumbnails/11.jpg)
Elektromehaničke i električne pretvorbe energije ZADACI ZA VJEŽBU
11
10. Trofazni asinkroni motor 100 kW, 50 Hz, 970 r/min diže teret brzinom 1,2 m/s kod čega ima brzinu vrtnje 983 r/min. Kojom brzinom motor spušta isti teret u generatorskom režimu rada? Motor prelazi u generatorski režim rada tako da se zamijene dvije faze. Rješenje: vsp = -1,24 m/s
2 10000030 30 984.5 Nm970n
n
PMn π π
= = =
9701 1 0.031000
s n n
s s
n n nsn n−
= = − = − =
9831 0.0171000ts = − =
U području malih klizanja momentna karakteristika se može nadomjestiti pravcem pa vrijedi omjer
0.017 984.5 557.9 Nm0.03
t n tt n
t n n
M M sM Ms s s
= ⇒ = = =
Spuštanje tereta
557.90.03 0.017984.5
spn tsp n
n sp n
MM Ms ss s M
= − =⇒ = − = − = − - generatorski režim, negativno
klizanje ( ) ( )1 1000 1 0.017 1017 r/minsp s spn n s= − − = − − − = −⎡ ⎤⎣ ⎦
10171.2 1.24 m/s983
spsp d
t
nv v
n−
= = = −
![Page 12: Auditorne_vjezbe_-_asinkroni](https://reader031.vdocuments.pub/reader031/viewer/2022020217/55204e7e497959892f8b4956/html5/thumbnails/12.jpg)
Elektromehaničke i električne pretvorbe energije ZADACI ZA VJEŽBU
12
11. Trofazni kolutni asinkroni motor radi u režimu asinkronog generatora. U rotorski krug dodan je omski otpor tako da brzina vrtnje generatora iznosi 1250 r/min, a kočni moment na osovini je 196 Nm. Motor je 6-polni, frekvencija mreže je 50 Hz, a gubici u bakru i željezu statora iznose 5 kW. Mehaničke gubitke, kao i gubitke u željezu rotora, zanemarite. Izračunajte: a) snagu kočenja na osovini motora, b) klizanje, c) gubitke u rotoru, d) snagu okretnog polja, e) snagu koju generator predaje mreži. Rješenje: P2 = -25,66 kW, b) st = -0,25, c) PRdod + Pcu2 = 5,13 kW, d) Pokr = -20,53 kW, e) P1 = -15,53 kW
Mm
M
s
Mt
1 0
Generatorsko kočenje
Mn
snst
MmRdod
2102
60 60 50 1000r/min
3sfn
p⋅
= = =
a) 21250196 25.66 kW
30 30nP M M π πω= = = − = −
b) 12501 1 0.251000
st
s s
n n nsn n−
= = − = − = −
c) ( )( )
22
25.660.25 5.13 kW
1 1 1 0.25dod
mehR Cu t okr t t
t t
P PP P s P s ss s
−+ = = = − =
− − − −
d) ( )
2 25.66 20.53 kW1 1 1 0.25
mehokr
t t
P PPs s
= = − = −− − − −
e) 1 1 1 20.53 5 15.53 kWokr Cu FeP P P P= + + = − + = − - snaga je negativna jer se predaje u mrežu
![Page 13: Auditorne_vjezbe_-_asinkroni](https://reader031.vdocuments.pub/reader031/viewer/2022020217/55204e7e497959892f8b4956/html5/thumbnails/13.jpg)
Elektromehaničke i električne pretvorbe energije ZADACI ZA VJEŽBU
13
12. Pri nazivnom naponu 400 V, 50 Hz, potezni moment kaveznog asinkronog motora Mk je 170 % nazivnog momenta, a potezna struja Ik(struja kratkog spoja) 600% nazivne. Koliki bi bili potezni moment i potezna struja ako bi napon snizili na 80 % nazivne vrijednosti. Rješenje: Mk = 108,8 % Mn , Ik = 480% In.
0.80.8 6 0.8 4.8 480%n
k k n n nn
UI I I I IU
= = ⋅ = =
22
0.80.8 1.7 0.8 1.088 108.8%n
k k n n nn
UM M M M MU
⎛ ⎞= = ⋅ = =⎜ ⎟
⎝ ⎠
![Page 14: Auditorne_vjezbe_-_asinkroni](https://reader031.vdocuments.pub/reader031/viewer/2022020217/55204e7e497959892f8b4956/html5/thumbnails/14.jpg)
Elektromehaničke i električne pretvorbe energije ZADACI ZA VJEŽBU
14
13. Koliko se smanji potezna struja u namotima trofaznog asinkronog motora, a koliko u dovodima iz mreže do motora, ako motor predviđen za stalni pogon u spoju trokut prespojimo u spoj zvijezda pri pokretanju i priključimo na istu mrežu? Skiciraj spoj u trokut i spoj u zvijezdu trofaznog asinkronog motora! Odgovor: U dovodima iz mreže 3 puta, a u fazama namota 3 puta. U - linijski mrežni napon
fI Δ - fazna struja u spoju trokut
3l fI IΔ Δ= - linijska struja u spoju trokut
3fYUU = - fazni napon u spoju zvijezda
fU UΔ = - fazni napon u spoju trokut
133
fYfY f f f
f
UU
I I I IU UΔ Δ Δ
Δ
= = = - fazna struja u spoju zvijezda
1 1 133 3 3
llY fY f l
II I I IΔΔ Δ= = = = - linijska struja u spoju zvijezda
![Page 15: Auditorne_vjezbe_-_asinkroni](https://reader031.vdocuments.pub/reader031/viewer/2022020217/55204e7e497959892f8b4956/html5/thumbnails/15.jpg)
Elektromehaničke i električne pretvorbe energije ZADACI ZA VJEŽBU
15
14. Kolika će biti struja pokretanja trofaznog asinkronog motora priključenog na mrežu 400 V, 50 Hz preklopkom Y/Δ (dakle u spoju Y), ako je pokusom kratkog spoja pri naponu 0,5 Un i u spoju Δ motor uzimao iz mreže 120 A? Podaci s natpisne pločice motora su: 20 kW, 400 V, 50 Hz, cosφ = 0,8, η=0,88, spoj namota Δ. Koliko iznosi nazivna struja motora i koliki bi bio omjer nazivne i potezne struje pri direktnom pokretanju motora? Rješenje: pokretanje u spoju zvijezda, struja u dovodima i fazama Ik =80 A. Nazivna struja u spoju trokut 41 A, Ik / In = 5,85.
0.5 0.51 120 40 A3 3n nkY U k UI I Δ= = =
0.5140 80 A
0.5 0.5n n
nkYU kY U
n
UI IU
= = ⋅ =
80 3 240 Ank UI Δ = ⋅ =
2 20000 41 A3 cos 3 400 0.8 0.88n
n
PIU ϕ ηΔ = = =
⋅ ⋅ ⋅
240 5.8541
k
n
II
Δ
Δ
= =