ENSURE POWER QUALITY, CONDUCT ENERGY AUDIT
SAVE 10 TO 20% IN ELECTRICITY BILLS
Department Of Electrical Engineering
Faculty Of Engineering and Technology
Jamia Millia Islamia,New Delhi-110025
CONTACT: Dr. V. K. SharmaTelefax: 26982651
Power Quality and Energy Audit Facility
at Electrical Engineering Department of
Jamia Millia Islamia,DELHI
Background:
Energy Saved is Energy Generated
India is facing grave crisis due to acute Shortage of Electrical Energy and ever growing demand.
With 80,000MW of installed capacity country needs an additional 80,000MW during the next
five years. Bulk of the Electricity is consumed by Industrial sector followed by Agriculture,
domestic and commercial applications. More than 70% of the electricity is consumed by electric
motors mainly in industry, agriculture and domestic appliances. Even a 5% saving in electricity
will prevent the need to install power plants of a few thousand MW. Energy conservation has
now become a necessity with Government of India formulating mandatory Energy Audit and
Energy conservation regulations.
Considerable energy saving is possible through proper choice of equipment, and their effective
use. Data of energy consumption pattern through Energy Audit for any given application
essential to evolve conservation measures. Since diagnosis proceeds treatment ant not an end in
itself one should find technical solution for the problem of inefficient energy use. In view of the
above, a State of the Art Electrical Energy Audit and Energy Conservation facility has been
established.
Facilities Established
Following facilities/laboratory have been established
1- Energy Instrumentation facility
2- Computerized test facility for Energy Converters and drives3- Computation and CAD facility for Energy System
4- Electrical Machine Design Center.
Electrical Energy Audit:
-
8/8/2019 pq_pamphletweb_el
2/6
ENSURE POWER QUALITY, CONDUCT ENERGY AUDIT
SAVE 10 TO 20% IN ELECTRICITY BILLS
Electrical Energy Audit for different establishments can be carried out by the sophisticated
Instrumention and Data acquisition facility comprising the following instruments and accessories
1. PLC BASED DATA ACQUISTION SYSTEM
FOR TESTING MOTOR & DRIVES
PLC-5/30 (Allen Bradley-USA)
Power Monitor (Allen Bradley-USA)
Variable Freq. Drive (Allen Bradley-USA)
Digital DC Drive (Kirloskar- India)
Torque Transducer (Vibrometer- Switzerland)
2. INSTRUMENTION FACILITY
a) Power Analyzer
3Phase(PM3300) Voltech (UK)
3Phase(PM300) Voltech (UK)
Single Phase(Pm100) Voltech (UK)
B) Oscilloscopes
4Channel Oscilloscope Hewlett Packard(USA)
(54602b)
Tektronix Real Time Tektronix (USA)
(TSH720)
Scope Meter Fluke (Holland)
C) Clamp On Current/Voltage/Power Meter
Digital ClampMeter Kyorisu (Japan)
Digital Clamp-On Tester Yokogawa (Japan)
AC/DC Clamp Meter Fluke (Holland)
HP974A Multimeter Hewlett Packard (USA)
HP34401A Multimeter Hewlett Packard (USA)
D) Non-Electrical Quantity Meters
Digital Tachometer Yokogawa (Japan)
Digital Thermometer Yokogawa (Japan)
Illuminance Meter Yokogawa (Japan)
Sound Level Meter Yokogawa (Japan)
Portable Lux Meter Yokogawa (Japan)
-
8/8/2019 pq_pamphletweb_el
3/6
-
8/8/2019 pq_pamphletweb_el
4/6
ENSURE POWER QUALITY, CONDUCT ENERGY AUDIT
SAVE 10 TO 20% IN ELECTRICITY BILLS
Commercial Establishments e.g: Hotels, shopping complexes
Computer Centers/ IT users
Domestic Sector
Types of Energy Audit:
Energy Audit is a comprehensive study having following
typical applications of electrical energy
= Motors driving pumps, blowers, compressors and fans
= Substation/Lighting
= Illumination/Lighting
= Electric Furnaces/Heating
= Electric Appliances
Since motors are the workhorses in industry they are the major energy guzzlers. We should
ensure their more efficient operation which may lead to energy labeling. Considerable energy
saving is possible by improved power transmission in Drive and use of energy efficient
equipment,s. Energy audit often includes power quality to assess the nature of supply voltages,
unbalance, frequency and waveform, based on which suggestions may emerge to improve
power quality. Sophisticated instrumentation procured by us. Facilitates detailed studies to
arrive at appropriate solutions.
Total Solution Ensured:
Apart from the sophisticated and State of Art facility created as above, IIT Delhi has faculty
with international level of expertise in the following areas. Electrical Machines & Drives
Power Systems & load Management
Power Electronics
Fluid & Solid Machines
Machine Dynamics
Computers and Instrumentation
Thermodynamics
Air conditioning
Total solution to the Electricity consumption problem towards considerable energy saving canbe ensured by the above combination of infrastructure and expertise. After conducting Energy
Audit Studies, a comprehensive technical report suggesting specific actions would be provided
to the clients.
How to contact?
-
8/8/2019 pq_pamphletweb_el
5/6
ENSURE POWER QUALITY, CONDUCT ENERGY AUDIT
SAVE 10 TO 20% IN ELECTRICITY BILLS
Interested Organizations/ Individuals may send response form in the given format to make use of
this facility.
Energy Audit/ Energy Conservation Facility
at Jamia Millia Islamia
Response Form
Name :
Organization:
Address:
Tel No:
FAX:
E mail:
Nature of organization:
We are interested in Power Quality and Energy Audit Studies to be carried out in our
organization.
Typical problem to be studied if any:
(Signature)
Send to :
-
8/8/2019 pq_pamphletweb_el
6/6
ENSURE POWER QUALITY, CONDUCT ENERGY AUDIT
SAVE 10 TO 20% IN ELECTRICITY BILLS
Dr. V. K. Sharma (Reader)
Dept of Electrical Engineering
Faculty of Engg. & Technology
Jamia Millia Islamia, New Delhi-110025
Tel No : 26982651
The scope of proposed energy audit work shall include
1. Review of plant electrical demand and evaluate the possibility of improving power factor.
2. Assessment of pump performance in order to improve its energy efficiency.
3. Total Load Survey
4. Power Quality Information including Harmonics
5. Study of Lighting Load measurement and examine the feasibility of incorporating the energy
efficient lighting to reduce the unit consumption in the campus.
6. Review and development of management information system for effective monitoring of total
energy consumption to attain an optimum value through implementation of necessary
corrective measures.