CommScope 365-301-136-5Instruction Sheet Issue 6, February 2004
Material ID 848 143 517
© 2007 CommSco pe, Inc. Al l Right s Res erved
Printed i n U.S.A.
Page 14 Pages
DIGITAL DISTRIBUTING FRAME (DDF)INSTALLATION PROCEDURES FOR
2-INCH (50 mm) PANELS
General
The Digital Distributing Frame (DDF) 2-inch (50 mm) panels are designed to mount in either 23-inch (584 mm)or 19-inch (482 mm) frames. Panels are equipped with dual monitor DDF modules. Panels for 23-inch (584
mm) frames contain ten DDF modules mounted horizontally in five rows of two modules. Panels for 19-inch(482 mm) frames contain eight DDF modules mounted horizontally in four rows of two modules.
How to Contact Us• To find out more about Carrier Apparatus products, visit us on the web at:
http://cw.commscope.com/
• For technical assistance regarding Carrier Apparatus products: contact your local CommScope accountrepresentative or CommScope technical support at 1-800-344-0223.
• Report any missing or damaged parts to CommScope customer s ervice in Omaha, Nebraska, at1-866-539-2795.
References
• 365-301-136 — Digital Distributing Frame (DDF) System Reference Guide
More product documentation for Digital Distributing Frames is available at the following CommScope webaddress: http://cw.commscope.com/eng/index.html — click Support & Documentation
Tools Required
Ordering Information
• Flat-blade 0.2-inch (5 mm) wide, 6-inch (152 mm) long screwdriver
Apparat us Code Materi al ID Descript ion
DDF-1B-01 107 538 597 Front cross-connect DDF module with single monitor port.
DDF-DM-1B-01 107 917 163 Front cross-connect DDF module with dual monitor port.
DDF-DM-NE-1B-01 107 922 197 Rear cross-connect DDF module with dual monitor port.
DDF-DM-1A600-8/2BNC 108 166 958 Eight circuit, front cross-connect dual monitor DDF-2-inch (50 mm) Hby 19-inch (482) mm) W panel. Modules are mounted horizontally.
DDF-DM-NE-1A500-8/2BNC 760 011 072 Eight circuit, rear cross-connect DDF 2-inch (50mm) H by 19-inch(482) mm) W panel. Modules are mounted horizontally.
DDF-DM-1A600-10/2BNC 108 186 941 Ten circuit, front cross-connect dual monitor DDF 2-inch (50 mm) H
by 23-inch (584 mm) W panel. Modules are mounted horizontally.DDF-DM-NE-1A600-10/2BNC 760 011 056 Ten circuit, rear cross-connect DDF 2-inch (50 mm) H by 23-inch
(584 mm) W panel. Modules are mounted horizontally.
7/28/2019 848_143_517
http://slidepdf.com/reader/full/848143517 2/4
Materi al ID 848 143 517Instruction Sheet
Page 24 Pages
INSTALLING AND REMOVING THE DDF MODULE
Installing the DDF Module in the 2-Inch (50 mm) Panel :
1. Position module at an angle to the panel so that the right side of the module is close to the tab molded into
the panel (see Figure 1).2. With bottom of module on tab, swing module up until it contacts panel and continue to push until it locks in
place.
Figure 1. Installing the DDF Module in the 2-Inch (50 mm) Panel(Front Cross-Connect Panel Viewed From Top)
Removing the DDF Module From t he 2-Inch (50 mm) Panel:
1. Use a flat screwdriver or other blunt tool to press the latch at the top of the module (see Figure 2).
2. Swing module down and lift out of panel.
Figur e 2. Removing th e DDF Module From the 2-Inch (50 mm) Panel(Front Cross-Connect Panel Viewed From Top)
1
2FRONT
REAR
2
FRONT
REAR
MODULELATCH
ACCESS
Front of FrontCross-Connect Panel
1
Front of RearCross-Connect Panel
MODULELATCH
ACCESS
7/28/2019 848_143_517
http://slidepdf.com/reader/full/848143517 3/4
Page 34 Pages
Material ID 848 143 517Issue 6, February 2004
INSTALLING A 2-INCH (50 mm) PANEL IN A BAY FRAME
A typical 2-inch (50 mm) front cross-connect panel installation is shown in Figure 3. Install the panel using fourNo. 12-24 by 3/8-inch screws.
Figure 3. Installing a 2-Inch Front Cross-Connect Panel i n a Bay Frame(Typical f or a Front Cross-Connect Panel)
Installing a 2-Inch Rear Cross-Connect Panel in 19-Inch and 23-Inch Bay Frames
A typical 2-inch (50 mm) rear cross-connect panel installation in a 19-inch frame is shown in Figure 4 on page4, and Figure 5 on page 4 shows the same panel being installed in a 23-inch frame with adapter brackets.
7/28/2019 848_143_517
http://slidepdf.com/reader/full/848143517 4/4
Materi al ID 848 143 517Instruction Sheet
Page 44 Pages
Figure 4. Installing a 2-Inch Rear Cross-Connect Panel in a 19-Inch Bay Frame
Figure 5. Installing a 2-Inch Rear Cross-Connect Panel in a 23-Inch Bay Frame
LabelHolder
CableBracket
AdapterBrackets
LabelHolder Cable
Bracket