ee6352 unit 5

68
Unit - 5 Analog and Digital Instruments

Upload: mohammad-akram

Post on 17-Jan-2017

35 views

Category:

Education


0 download

TRANSCRIPT

Page 1: Ee6352 unit 5

Unit - 5

Analog and Digital Instruments

Page 2: Ee6352 unit 5

Digital Voltmeter (DVM) Used to measure the ac and dc voltages and displays the

result in digital form.

Types: Ramp type DVM Integrating type DVM Potentiometric type DVM Successive approximation type DVM Continuous balance type DVM

Page 3: Ee6352 unit 5

Advantages:

1. Errors on account of parallax and approximations are entirely eliminated

2. Operating speed is increased3. Data can be fed to memory devices for storage

and future computation.4. Size reduced after the advent of ICs and easily

portable.

Page 4: Ee6352 unit 5
Page 5: Ee6352 unit 5

Ramp type DVM

Principle:Input voltage is converted into digital equivalent

by counting the time taken for the ramp wave to decrease from the magnitude of input voltage to 0V.

Construction:The block diagram of the Ramp-type ADC can be

divided into two sections as follows: 1. Voltage to time conversion section 2. Time measurement section

Page 6: Ee6352 unit 5

Voltage to time conversion section In the voltage to time conversion section, the analog

input voltage is fed to the attenuation circuit. The attenuated signal is compared with the the ramp signal generated by the ramp generator given in the block diagram by the input comparator 'C1'. Similarly, The ramp signal generated is compared with 0V via a zero-crossing detector 'C2'. A sample rate multivibrator is connected to the ramp generator whose purpose is to provide an initiating pulse for the ramp generator to start the next ramp voltage for the next measurement. It is also used to reset the counter before generating the next ramp voltage.

Page 7: Ee6352 unit 5

Time measurement section

In the time measurement section, there is counter which is triggered by a gating pulse. The inputs of the gating pulse are (i) Output of 'C1' (ii) Output of 'C2' (iii) Clock pulse from the oscillator. The counter is reset after each successful completion of time measurement by a control signal from the sample rate multivibrator. The count produced is displayed by connecting suitable display device.

Page 8: Ee6352 unit 5

Operation Initially, the attenuated signal is compared with a

negative going ramp signal generated by the ramp generator. When the ramp voltage coincides with the input signal, the output of 'C1' becomes low. This point is called coincidence point. This initiates the counting process ( start of count ). The counter continues to count until the ramp voltage reduces and crosses zero (0V). This is detected by zero crossing detector 'C2'. The output of 'C2' becomes high which ends the counting process (end of count).

Page 9: Ee6352 unit 5

Triangular wave displaying Ramp type

Page 10: Ee6352 unit 5
Page 11: Ee6352 unit 5

Waveform

The count displayed is the count of number of clock pulses produced by the oscillator during the time in which the ramp signal is less than the input signal and greater than 0V (ie) |input signal| > ramp > 0V. This count gives the digital equivalent of input analog voltage.

Page 12: Ee6352 unit 5

DVM

Equations Involved:

(∆)t = t2 - t1= Vin/m = nT ;

Hence, Vin = nmT;

where

t1-> start of count

t2-> end of count

Vin-> input analog voltage

m-> slope of the ramp curve

n-> number of clock pulses to counter

T-> clock period

Page 13: Ee6352 unit 5

DVM

Merits: low cost simple, easy to design long distance transmission of output pulse is possible

Demerits: accuracy of output greatly depends on linearity of the ramp.

(since only one ramp is used) input filter are needed for filtering noise from input signal.

Page 14: Ee6352 unit 5

Dual Slope Integrating type DVM

Page 15: Ee6352 unit 5

Block Diagram of Integrator type DVM

Page 16: Ee6352 unit 5

Waveform of output voltage

Page 17: Ee6352 unit 5

Potentiometric type Digital voltmeter

Page 18: Ee6352 unit 5

Digital Multimeter

Page 19: Ee6352 unit 5

Table of Contents

Introduction Working Block diagram Application

Page 20: Ee6352 unit 5

Introduction

Digital multimeter is an instrument used to measure voltage, current and resistance and display the measured voltage using LCD or LED to display the results in floating point format

Page 21: Ee6352 unit 5

Special characters

DMM has a variety of special features that are designed for a wide number of applications

Frequency Temperature Capacitance Continuity check Diode check

Page 22: Ee6352 unit 5

Block diagram

Page 23: Ee6352 unit 5

Parts of a DMMIntegrator:

The integrator stabilizes the voltage as a first step in measuring it. It takes a brief time sample, integrates it and outputs a proportional voltage. Integrating a time sample makes the voltmeter more immune to noise in the signal.

A/D converter:

The analog/digital converter is a clocked circuit that takes the sampled input voltage and outputs a number representing the voltage value. Since it is clocked, we get a steady stream of numbers that change when the input voltage changes.

Zeroing & Sampling:

A digital voltmeter needs to know where zero is in order to give a true reading. This is done with a precision zero reference voltage provided either internal to the ADC chip or externally.

Display:

The digital display requires a river circuitry to handle the drive current. An ADC chip converts the generated analog signal to digital data and is displayed in the LCD.

Page 24: Ee6352 unit 5

Advantages

Easy to handle Very accurate Noise signals absent Portable Has very good resolution

Page 25: Ee6352 unit 5

Digital Storage Oscilloscope

Page 26: Ee6352 unit 5

Measurement of resistance

Wheatstone bridge Kelvin bridge

Page 27: Ee6352 unit 5

Wheatstone bridge

The Wheatstone Bridge was originally developed by Charles Wheatstone to measure unknown resistance values and as a means of calibrating measuring instruments, voltmeters, ammeters, etc, by the use of a long resistive slide wire. Although today digital multimeters provide the simplest way to measure a resistance, The Wheatstone Bridge can still be used to measure very low values of resistances down in the milli-Ohms range.

Page 28: Ee6352 unit 5

Wheatstone Bridge Circuit

Page 29: Ee6352 unit 5
Page 30: Ee6352 unit 5

Kelvin bridge

Page 31: Ee6352 unit 5

Derivation

Page 32: Ee6352 unit 5

Kelvin Double Bridge

Page 33: Ee6352 unit 5

Kelvin Double Bridge

Page 34: Ee6352 unit 5

Derivation

Page 35: Ee6352 unit 5

Measurement of Inductance

Inductance can be measured by, Maxwell Bridge Anderson Bridge

Page 36: Ee6352 unit 5

AC Bridge

Page 37: Ee6352 unit 5

Derivation

Page 38: Ee6352 unit 5

AC bridge

Page 39: Ee6352 unit 5

Maxwell Inductance bridge

Page 40: Ee6352 unit 5

Maxwell Inductance Capacitance Bridge

Page 41: Ee6352 unit 5

Advantages

The frequency does not appear in the final expression of both equations, hence it is independent of frequency.

Maxwell's inductor capacitance bridge is very useful for the wide range of measurement of inductor at audio frequencies.

Page 42: Ee6352 unit 5

Disadvantages

The variable standard capacitor is very expensive.

The bridge is limited to measurement of low quality coils (1 < Q < 10) and it is also unsuitable for low value of Q (i.e. Q < 1) from this we conclude that a Maxwell bridge is used suitable only for medium Q coils.

Page 43: Ee6352 unit 5

Anderson Bridge

This bridge is the modified version of Maxwell Inductance Capacitance Bridge.

Double balance can obtained by fixing the value of capacitance and changing the value of electrical resistance only.

Page 44: Ee6352 unit 5

Circuit diagram

Page 45: Ee6352 unit 5

Derivation

Page 46: Ee6352 unit 5

Derivation

Page 47: Ee6352 unit 5

Derivation

Page 48: Ee6352 unit 5

Advantages

It is very easy to obtain the balance point in Anderson's bridge as compared to Maxwell bridge in case of low quality factor coils.

There is no need of variable standard capacitor is required instead of thin a fixed value capacitor is used.

This bridge also gives accurate result for determination of capacitance in terms of inductance.

Page 49: Ee6352 unit 5

Disadvantages

The equations obtained for inductor in this bridge is more complex as complex as compared to Maxwell's bridge.

The addition of capacitor junction increases complexity as well as difficulty of shielding the bridge.

Considering all the advantages and disadvantages, Maxwell bridge is preferred over Anderson's bridge whenever use of variable capacitor is permissible.

Page 50: Ee6352 unit 5

Schering Bridge

This bridge is used to measure to the Capacitance of the capacitor Dissipation factor and Measurement of relative permittivity

Page 51: Ee6352 unit 5

Circuit diagram & Phasor diagram

Page 52: Ee6352 unit 5

Derivation

Page 53: Ee6352 unit 5

Derivation

Page 54: Ee6352 unit 5

Advantages

The balance equation is independent of frequency.

It is used for measuring the insulating properties of electrical cables and equipments.

Page 55: Ee6352 unit 5

Wiens bridge

Page 56: Ee6352 unit 5

Derivation

Page 57: Ee6352 unit 5

Derivation

Page 58: Ee6352 unit 5

High frequency measurements

We are going to see the measurement of R,L,C for frequency range 0.1 to 100MHz.

Some special effects are predominant at high frequency High reactance due to stray series inductance and its variation with

frequency Low reactance due to stray shunt inductance and its variation with

frequency Increase of effective resistance with frequency on account of skin effect. Increase of effective resistance on account of proximity effect. Increase of effective resistance due to production of eddy current

Variation of dielectric loss of capacitors with frequency.

Page 59: Ee6352 unit 5

Measurement of inductance by Resonance method

Page 60: Ee6352 unit 5

Measurement of capacitance

Page 61: Ee6352 unit 5

Measurement of effective resistance by Resistance variation method

Page 62: Ee6352 unit 5

Measurement of effective resistance by Reactance variation method

Page 63: Ee6352 unit 5

Variation of frequencyThe capacitance C is kept constant and the frequency is varied. Let ω0 be the angular

frequency to give maximum current Io and ω1 & ω2 be the two frequencies which give the value of current I=Io/

2R = (ω1L-1/ ω1C) – (ω2L-1/ ω2C)

= (ω1- ω2)L + ω02L(ω1- ω2)/ω1ω2 as ω0

2L = 1/C

Now for a peak and symmetrical resonance curve,

ω02=ω1ω2

2R = (ω1- ω2)L + ω02L(ω1- ω2)/ω0 = 2 (ω1- ω2)L

R = (ω1- ω2)L

= (ω1- ω2)/ω02C

Quality factor is,

Q = ω0L/R = ω0/(ω1- ω2)

Page 64: Ee6352 unit 5

T-networks

Parallel T-networkBridge T-network

Page 65: Ee6352 unit 5

Parallel T-network

Page 66: Ee6352 unit 5

Parallel T-network for measurement of frequency

Page 67: Ee6352 unit 5

Bridge T-network

Page 68: Ee6352 unit 5

Q-Meter