vacuettesystem_b

Upload: noelescorpion

Post on 09-Apr-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/8/2019 VACUETTESystem_b

    1/2

    Leading technology for higher demands

    Stamp of distributor

    > One Step Ahead

    *2,5ml

    454321

    454096

    454028*

    454089

    454097

    454087

    454061

    454085

    454073

    454325

    454095

    454082

    454086

    454094

    729090

    454092

    454071

    454084

    454083

    454051

    454036

    454062

    454091

    456071

    456083

    456092

    456084

    456051

    456036

    456062

    455071

    455083

    455092

    455084

    455051

    455036

    VACUETTECoagulation VACUETTESerum VACUETTE Plasma

    These tubes are used for deter-minations in citrated plasma forcoagulation testing. The bufferedsodium c i trate solu t ion 3 .2%(0.109mol/l) functions as anticoagulantby chelating calcium. The proportionof blood to sodium citrate anticoagulantvolume is 9:1.

    Serum Tubes are used for deter-minations in serum for clinicalchemistry, microbiological serology,immunology and TDM. The tubes arecoated with a clot activator. Therecommended clotting time is 30minutes. Serum Gel Tubes allowstorage of certain parameters underthe recommended storage conditionsfor up to 48 hours.

    The tubes are used for determinationsin plasma for clinical chemistry. Theheparin concentration is standardised:18 I .U. of l ithium-, sodium- orammonium salt of heparin per 1 ml.Plasma Gel Tubes allow storage ofcertain parameters under therecommended storage conditions forup to 48 hours.

    VACUETTEEDTA VACUETTEGlucose VACUETTE ESR

    EDTA Tubes are used for deter-minations in EDTA whole blood for

    h a e m a t o l o g y a n d i m m u n ohaematology. The tube interior of EDTAK3 Tubes is spray dried with 1.8mganhydrous EDTA per 1 ml blood.

    Glucose Tubes are used for the analysisof blood sugar and lactate in stabilised

    whole blood or plasma. Sodium fluorideis used as glycolysis inhibitor topreserve glucose when combined withan anticoagulant such as potassiumoxalate or EDTA.

    Sodium c i trate solu t ion 3 .2%(0.109mol/l) is the anticoagulant of

    choice for the measurement of the ESR.The proportion of blood to sodiumcitrate anticoagulant volume is 4:1.

    Paediatric

    Greiner Bio-One GmbHBad Haller Str. 32

    A-4550 KremsmnsterTel: +43 (0) 7583 6791-0Fax: +43 (0) 7583 6318

    [email protected]

    ev.

    00,

    08.

    2005

    e

    Gel

    Standard

    Tube Size

    ml

    Trisodium citratesolution

    Clot Activator

    Clot Activator+ Gel

    Lithium Heparin

    Lithium Heparin+ Gel

    13/75 13/75 13/100 13/100 16/100

    Sodium Heparin

    Sodium fluoridePot. oxalate

    13/75

    2 3 4 5 6 8 9

    16/100

    ClinicalC

    hemistry

    Specialities

    Haematology

    Capcolour

    Ring colours

    EDTA K3

    Trisodium citratesolution

    ESR

    Sodium fluorideEDTA K3

    FE

    FX

    K3E

    9NC

    NH

    LH

    LH

    Z

    Z

    Coagulation

    Specimen Collection System

  • 8/8/2019 VACUETTESystem_b

    2/2

    one step ahead

    Specimen Collection System Leading technology for higher demands

    The invention of the world`s first evacuated bloodcollection system made out of PET plastic by GreinerBio-One has made specimen collection a lot safer.The innovative VACUETTE system guarantees simplehandling and hygiene in order to makeyour daily workeasier.

    The VACUETTE system combines the advantages ofvacuum technology with unique safety characteristics fothe patient and the user.

    Specification>> clear as glassbutvirtually unbreakable

    >> colour coded screw caps formore safety

    >> colour coded rings offer additionalvisualidentification of tubes

    >> wide range of PET tubes with differentadditives anddraw volumes

    >> compatible with all common analyser systems

    Safety

    >> unbreakable during centrifugation, handling

    and transportation

    >> allVACUETTEtubes are sterile

    >> reproducibilityisguaranteed

    >> fast & reliabletest results

    >> VACUETTESandwich tubewith patented doublewall technology; the perfect solution (NCCLSrecommendation) for coagulation tests

    >> incineration ofVACUETTE tubes are harmless forthe environment and incineration products aremainly water (H2O) and carbon dioxide (CO2)

    Standards>> VACUETTE products are US FDA approved

    >> manufacturing complies to EC directives andUS regulations (ISO 9001, GMP)

    Instruction for use Short discription

    Apply tourniquet (max. 1 minute)Prepare venipuncture site with anappropriate antiseptic.

    Remove needle shield. Performvenipuncture with arm in downwardposition, with the tube cap upper-most.

    Push tube into the holder. REMOVETOURNIQUET AS SOON ASBLOOD APPEARS IN TUBE. Ensurecomplete vacuum draw.

    Gently invert the tubes 5-10 times(exceptions: coagulation tubes -invert 4 times; EDTA tubes - invert 8-10 times) immediately after bloodcollection to reach a proper mix ofadditive and blood.

    Dispose of the used needle with holderusing an appropriate disposal device.

    Components

    VACUETTE Tourniquet

    Multisample needle

    Winged BloodCollection Set

    Standard Tube Holder

    VACUETTEBloodCollection Tube

    Disposal Containers

    for more detail please see:

    www.gbo.com/preanalytics