کنترل تطبيقى سيستمهاى hvac

19
1 مهاى ت س سي ى ق ي ب ط ت رل ت ن کHVAC ع: ج را م Energy simulation of traditional vs. Adaptive thermal comfort for two moderate climate regions J.L.M. Hesen, L. Centnerova Advanced controller auto-tuning and its application in HVAC systems Qiang Bi, Wen-Jian Cai, Qing-Guo Wang, Chang- Chieh Hang, Eng-Lock Lee, Yong Sun, Ke-Dian Liu, Yong Zhang, Biao Zou Intelligent Adaptive Control: Intelligent Control of Air Conditioning Systems Jain; Lakhmi C., de Silva; Clarence W.

Upload: mufutau-bell

Post on 03-Jan-2016

35 views

Category:

Documents


2 download

DESCRIPTION

کنترل تطبيقى سيستم‌هاى HVAC. مراجع: Energy simulation of traditional vs. Adaptive thermal comfort for two moderate climate regions J.L.M. Hesen, L. Centnerova Advanced controller auto-tuning and its application in HVAC systems - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: کنترل تطبيقى سيستمهاى  HVAC

1

سيستمهاى تطبيقى HVACکنترل

: مراجع

Energy simulation of traditional vs. Adaptive thermal comfort for two moderate climate regions

J.L.M. Hesen, L. Centnerova

Advanced controller auto-tuning and its application in HVAC systems

Qiang Bi, Wen-Jian Cai, Qing-Guo Wang, Chang-Chieh Hang, Eng-Lock Lee, Yong Sun, Ke-Dian Liu, Yong Zhang, Biao Zou

Intelligent Adaptive Control: Intelligent Control of Air Conditioning Systems

Jain; Lakhmi C., de Silva; Clarence W.

Page 2: کنترل تطبيقى سيستمهاى  HVAC

2

مقدمه

از چيست؟ HVACمنظورBiotherium چيست؟ حرارتى تعريف راحتى شرايط چيست؟ تنظيم خود سيستم يک چيست؟ هوشمند تطبيقى کنترل سيستم از منظور

Page 3: کنترل تطبيقى سيستمهاى  HVAC

3

بحث مورد مطالب

توليد کارخانه يک در مطبوع تهويه سيستم يکمصنوعى نخ

بينا مطبوع تهويه سيستم يک سوى به گامى

يک در مطبوع تهويه سيستم clean roomيک

Page 4: کنترل تطبيقى سيستمهاى  HVAC

4

با مصنوعى نخ توليد کارخانه يک در مطبوع تهويه سيستم يکقابليت

انرژى صرفهجويىTerephthalic acid

+

Ethylene glycol

(Raw material)

Polymerization

Process

Spinning

Process

Drawing/twisting

Process

Polyester

filament

Role of Air conditioning system:

Aging of yarn yet to be drawn Prevention of yarn from changing

physical properties before drawing Maintaining level of dyeing Prevention of occurrence of yarn cut

and fluff Purification of room atmosphere

[3]

Page 5: کنترل تطبيقى سيستمهاى  HVAC

5

انرژى صرفهجويى جهت فازى کنترل با مطبوع تهويه سيستم

Page 6: کنترل تطبيقى سيستمهاى  HVAC

6

فازى قوانين

Page 7: کنترل تطبيقى سيستمهاى  HVAC

7

نتايج

Page 8: کنترل تطبيقى سيستمهاى  HVAC

8

تشخيصموقعيت قابليت با مطبوع تهويه سيستمساکنان

1. Distinguish occupants from background in an image using the Fuzzy C-Means algorithm (FCM)

2. Distinguish each occupant by locating local temperature peaks in the image

3. Region growing for more accurate segmentation of occupants

Page 9: کنترل تطبيقى سيستمهاى  HVAC

9

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

1 81 84 82 64 68 74 75 80 74 72 73 69 85 75 76 77 77 80 83 75

2 78 82 82 71 73 71 63 73 72 62 72 66 78 78 69 83 86 84 83 76

3 80 72 82 74 82 73 70 71 74 62 55 59 96 101 111 132 118 84 71 68

4 71 75 77 65 71 75 72 72 66 42 38 80 164 162 131 113 86 74 68 66

5 78 76 69 55 63 120 151 135 93 66 66 79 107 108 98 93 91 81 82 80

6 53 69 77 32 50 149 215 207 133 84 73 70 70 67 63 65 73 78 84 78

7 54 78 87 51 47 121 186 197 138 71 71 58 66 70 72 65 69 82 89 85

8 62 72 76 57 65 79 92 102 86 64 65 56 64 67 64 72 73 76 82 73

Page 10: کنترل تطبيقى سيستمهاى  HVAC

10

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

1 81 84 82 64 68 74 75 80 74 72 73 69 85 75 76 77 77 80 83 75

2 78 82 82 71 73 71 63 73 72 62 72 66 78 78 69 83 86 84 83 76

3 80 72 82 74 82 73 70 71 74 62 55 59 96 101 111 132 118 84 71 68

4 71 75 77 65 71 75 72 72 66 42 38 80 164 162 131 113 86 74 68 66

5 78 76 69 55 63 120 151 135 93 66 66 79 107 108 98 93 91 81 82 80

6 53 69 77 32 50 149 215 207 133 84 73 70 70 67 63 65 73 78 84 78

7 54 78 87 51 47 121 186 197 138 71 71 58 66 70 72 65 69 82 89 85

8 62 72 76 57 65 79 92 102 86 64 65 56 64 67 64 72 73 76 82 73

Page 11: کنترل تطبيقى سيستمهاى  HVAC

11

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

1 81 84 82 64 68 74 75 80 74 72 73 69 85 75 76 77 77 80 83 75

2 78 82 82 71 73 71 63 73 72 62 72 66 78 78 69 83 86 84 83 76

3 80 72 82 74 82 73 70 71 74 62 55 59 96 101 111 132 118 84 71 68

4 71 75 77 65 71 75 72 72 66 42 38 80 164 162 131 113 86 74 68 66

5 78 76 69 55 63 120 151 135 93 66 66 79 107 108 98 93 91 81 82 80

6 53 69 77 32 50 149 215 207 133 84 73 70 70 67 63 65 73 78 84 78

7 54 78 87 51 47 121 186 197 138 71 71 58 66 70 72 65 69 82 89 85

8 62 72 76 57 65 79 92 102 86 64 65 56 64 67 64 72 73 76 82 73

Page 12: کنترل تطبيقى سيستمهاى  HVAC

12

با فازى رطوبت و دما کنترل سيستم يکيادگيرى قابليت

: معمول فازى کنترل سيستم

Page 13: کنترل تطبيقى سيستمهاى  HVAC

13

Temperature request and humidity request inference TRV: error of measured and desired temperature together

with its deviation HRV: foreseen error and deviation

Integrated inferenceIf x1 is Ai1, …, x5 is Ai5 then y1 is Bi1, …, y3 is Bi3

x1: last manipulated variable for the cooling valve

x2: last manipulated variable for the heating valve

X3: last manipulated variable for the humidifying valve

X4: temperature request

X5: humidity request

y1, y2, y3: change in manipulated variable for the cooling. heating and humidifying valve

Page 14: کنترل تطبيقى سيستمهاى  HVAC

14

يادگيرنده فازى کنترل سيستم

Page 15: کنترل تطبيقى سيستمهاى  HVAC

15

Page 16: کنترل تطبيقى سيستمهاى  HVAC

16

سازى شبيه نتايج

Page 17: کنترل تطبيقى سيستمهاى  HVAC

17

عملى نتايج

Page 18: کنترل تطبيقى سيستمهاى  HVAC

18

. سيستم يک نوعى HVACالف

[2]

Return to Introduction

Page 19: کنترل تطبيقى سيستمهاى  HVAC

19

. حرارتى راحتى شرايط ب“Condition of mind, which expresses satisfaction with the thermal

environment.” [1]

Criteria’s for thermal comfort (PMV index): Air temperature Radiant temperature Humidity Air velocity Personal parameters such as clothing and metabolic rate

Criteria’s for thermal discomfort: Draught High vertical temperature difference between head and ankles Too high radiant temperature asymmetry

“The optimum operative temperature for comfort is a function of metabolic rate and clothing insulation.” [1]