psv4723.24.pacpp
DESCRIPTION
...TRANSCRIPT
-
PIPEMILL - Piping Engineering, Design and AnalysisVersion: 3.01d Full Run TECHNIP ENGINEERING THAILAND LTD.
PSV AND RUPTURE DISC REACTION FORCE CALCULATION ____________________________________________________________________________________________________________
Calculation by: ____________________ Checked by: ______________________ Monday,Jan 26,2015
File Name: File name:
CLOSED DISCHARGE PSV REACTION FORCES BASED ON API RP 520, VAPOUR AND GASProject / Description:61395-TC&S DD for South Pailin Flar-Relief
PSV Tag No.:4723/24 Rev.
PSV Data Sht. No.:4723/24 Rev.
Stress Isometric No.:6"-GP-C1-8061 Rev.
INPUT DATA: FORCE LOCATION DIAGRAM:
Relief Temperature T: 223 deg. F.
Set Pressure P: 350 psig
Downstream Pressure Pd: 385 psig
Required Mass Flow Rate W: 72443 lb/hr.
Molecular Weight M: 43.92
Ratio of Specific Heats kc=Cp/Cv: 1.083
Required Orifice Area Ar: 3.32 in.2
Actual orifice Area Aa: 3.6 in.2 Valve Orifice Designation: M
Dynamic Amplification Factor daf: 2 __________________________________________________________________________________________________
F5
F4
Pop condit ion Established f low
OUTPUT DATA:
F1 = 610.15 lbf.
F2 = 270.44 lbf.
F4 = daf . F1 F4 = 1220.29 lbf.
F5 = daf . F2 F5 = 540.89 lbf.
End of calculation